1
|
Arceri A, Abdi P, Mazzotti A, Zielli SO, Artioli E, Langone L, Sgubbi F, Faldini C. Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study. J Pers Med 2024; 14:770. [PMID: 39064024 PMCID: PMC11278035 DOI: 10.3390/jpm14070770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 07/06/2024] [Accepted: 07/13/2024] [Indexed: 07/28/2024] Open
Abstract
PURPOSE This retrospective study aims to compare surgical outcomes between two cohorts of patients who underwent total ankle arthroplasty (TAA) using either standard technique or patient-specific instrumentation (PSI). METHODS A consecutive series of patients who affected of end-staged ankle osteoarthritis were retrospectively assessed and divided into two groups based on TAA techniques: a TAA standard technique group and a TAA-using PSI group. The two groups were compared in terms of operative time, additional procedures, complications (neurovascular and wound problems, infection, loosening and osteolysis, revision and explantation rates, and perioperative fracture), clinical scores, and range of motion (ROM). RESULT Fifty-one patients underwent standard TAA, while 13 patients underwent TAA with PSI. At 1-year follow-up, there were no significant differences in complication rates between the two groups (p > 0.05). AOFAS scores were similar, with the standard TAA group scoring 83.33 ± 7.55 and the PSI group scoring 82.92 ± 9.7 (p = 0.870). Likewise, the postoperative ROM did not differ significantly, with 15.12 ± 7.6 degrees for the standard TAA group and 16.05 ± 6.7 degrees for the PSI group (p = 0.689). However, the standard TAA group experienced significantly longer operative time (107.1 ± 22.1 min) compared to the PSI group (91.92 ± 22.9 min, p = 0.032). Additionally, the standard TAA group required more adjunctive procedures (29.7%) compared to the PSI group (7.7%, p = 0.04). Residual pain was also more frequently reported in the standard TAA group (62.7%) than in the PSI group (30.7%, p = 0.038). CONCLUSION While both techniques resulted in comparable complication rates, clinical scores and ROM, the PSI group reported significantly shorter operative time and less residual pain, thus requiring fewer postoperative procedures.
Collapse
Affiliation(s)
- Alberto Arceri
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Pejman Abdi
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Antonio Mazzotti
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy
| | - Simone Ottavio Zielli
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Elena Artioli
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Laura Langone
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Federico Sgubbi
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Cesare Faldini
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy
| |
Collapse
|
2
|
Arshad Z, Haq II, Bhatia M. Learning curve of total ankle arthroplasty: a systematic review. Arch Orthop Trauma Surg 2024; 144:591-600. [PMID: 37917408 DOI: 10.1007/s00402-023-05064-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 09/03/2023] [Indexed: 11/04/2023]
Abstract
INTRODUCTION Together with ankle arthrodesis, total ankle arthroplasty is now accepted as a first-line intervention in the management of end-stage arthritis of the ankle. The evidence regarding how outcomes are affected by surgeon experience is inconsistent; we performed a systematic review to evaluate the effect of a learning curve in total ankle arthroplasty outcomes. METHODS An electronic database search was performed in PubMed, Embase, ISI Web of Science and Cochrane trials. Two reviewers independently conducted a two-stage title/abstract and full text screening. English-language original research studies comparing patient-reported outcome measures (PROMs), complication/revision rates, operative time, length of stay or radiation exposure according to surgeon experience were included. Quality assessment was performed using the methodological index for non-randomised studies. RESULTS All but one included study report either improved PROMs, reduced complication/revision rate, reduced hospital stay length/operative time or reduced radiation exposure with increasing surgeon experience. However, the majority of these findings lack statistical significance. Two studies assessing the plateau of the learning curve report a wide range of plateau thresholds between 9 and 39 cases. CONCLUSION This review finds a largely non-significant trend towards improvements in PROMs, complication, and revision rates with improved surgeon experience. The lack of statistical significance in a number of studies may be partially explained by methodological flaws, with more suitably designed studies reporting significant improvements. Future research into the effect of advancements in implant design and insertion guides is required to further characterise the magnitude of the learning curve and guide both mitigation and learning strategies.
Collapse
Affiliation(s)
- Zaki Arshad
- Infirmary Square, University Hospitals of Leicester NHS Trust, Leicester Royal Infirmary, Leicester, LE1 5WW, UK.
| | - Ibrahim Inzarul Haq
- Infirmary Square, University Hospitals of Leicester NHS Trust, Leicester Royal Infirmary, Leicester, LE1 5WW, UK
| | - Maneesh Bhatia
- Infirmary Square, University Hospitals of Leicester NHS Trust, Leicester Royal Infirmary, Leicester, LE1 5WW, UK
| |
Collapse
|
3
|
Townshend D, Bing A, Blundell C, Clough T, Davenport J, Davies H, Davis J, Dhar S, Hepple S, Kakwani R, Karski M, Makwana N, McKinley J, Murty A, Raglan M, Shalaby H, Sharpe I, Smith R, Taylor H, Goldberg A. Two to Five-Year Outcomes of Total Ankle Arthroplasty with the Infinity Fixed-Bearing Implant: A Concise Follow-up of a Previous Report. J Bone Joint Surg Am 2023; 105:1846-1856. [PMID: 38063779 PMCID: PMC10695343 DOI: 10.2106/jbjs.22.01294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
LEVEL OF EVIDENCE Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- David Townshend
- Northumbria NHS Healthcare Trust, North Shields, England, United Kingdom
| | - Andrew Bing
- Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Trust, Oswestry, England, United Kingdom
| | | | - Tim Clough
- Wrightington Hospital, Wrightington, United Kingdom
| | | | - Howard Davies
- Northern General Hospital, Sheffield, United Kingdom
| | | | - Sunil Dhar
- Nottingham University Hospitals Trust, Nottingham, United Kingdom
| | - Steve Hepple
- Avon Orthopaedic Centre, Southmead Hospital, Bristol, United Kingdom
| | - Rajesh Kakwani
- Northumbria NHS Healthcare Trust, North Shields, England, United Kingdom
| | - Mike Karski
- Wrightington Hospital, Wrightington, United Kingdom
| | - Nilesh Makwana
- Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Trust, Oswestry, England, United Kingdom
| | | | - Aradhyula Murty
- Northumbria NHS Healthcare Trust, North Shields, England, United Kingdom
| | - Martin Raglan
- Nottingham University Hospitals Trust, Nottingham, United Kingdom
| | | | - Ian Sharpe
- Royal Devon and Exeter NHS Foundation Trust, Exeter, United Kingdom
| | - Robert Smith
- Wrightington Hospital, Wrightington, United Kingdom
| | - Heath Taylor
- Royal Bournemouth Hospital, Bournemouth, United Kingdom
| | | |
Collapse
|
4
|
Benignus C, Buschner P, Meier MK, Wilken F, Rieger J, Beckmann J. Patient Specific Instruments and Patient Individual Implants—A Narrative Review. J Pers Med 2023; 13:jpm13030426. [PMID: 36983609 PMCID: PMC10051718 DOI: 10.3390/jpm13030426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/20/2023] [Accepted: 02/25/2023] [Indexed: 03/02/2023] Open
Abstract
Joint arthroplasties are one of the most frequently performed standard operations worldwide. Patient individual instruments and patient individual implants represent an innovation that must prove its usefulness in further studies. However, promising results are emerging. Those implants seem to be a benefit especially in revision situations. Most experience is available in the field of knee and hip arthroplasty. Patient-specific instruments for the shoulder and upper ankle are much less common. Patient individual implants combine individual cutting blocks and implants, while patient individual instruments solely use individual cutting blocks in combination with off-the-shelf implants. This review summarizes the current data regarding the implantation of individual implants and the use of individual instruments.
Collapse
Affiliation(s)
- Christian Benignus
- Department of Traumatology and Orthopedic Surgery, Hospital Ludwigsburg, Posilipostr. 4, 71640 Ludwigsburg, Germany
| | - Peter Buschner
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Malin Kristin Meier
- Department of Orthopedic Surgery and Traumatology, Inselspital, University Hospital Bern, University of Bern, Freiburgstr. 4, 3010 Bern, Switzerland
| | - Frauke Wilken
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Rieger
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Beckmann
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
- Correspondence:
| |
Collapse
|
5
|
Zheng H, Wang L, Jiang W, Qin R, Zhang Z, Jia Z, Zhang J, Liu Y, Gao X. Application of 3D printed patient-specific instruments in the treatment of large tibial bone defects by the Ilizarov technique of distraction osteogenesis. Front Surg 2023; 9:985110. [PMID: 36684263 PMCID: PMC9852528 DOI: 10.3389/fsurg.2022.985110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 10/31/2022] [Indexed: 01/09/2023] Open
Abstract
Background The Ilizarov technique of distraction osteogenesis is an effective treatment for tibia defect. However, repeated attempts to reduce due to the complexity of the bone defect during the operation will increase the operation time and iatrogenic injury, and excessive radiation exposure. Three-dimensional (3D)-printed patient-specific instrument (PSI) for preoperative 3D planning and intraoperative navigation have the advantages of accuracy and visualization. The purpose of this study is to investigate whether 3D-printed PSI is helpful to correct tibial bone defects accurately and effectively. Method From May 2019 to September 2022, 19 patients with tibial bone defects were treated, including 9 males and 10 females, aged 37 to 64 years. There were 4 cases in proximal tibia, 9 in midshaft tibia and 6 in distal tibia. All were treated with Ilizarov technique of distraction osteogenesis. 3D-printed PSI was used in 9 cases, while traditional surgery was used in 10 cases. All patients underwent computed tomography before surgery. Computer software was used to analyze the measurement results, design and print PSI. During the operation, PSI was used to assist in reduction of tibia. Operation times were recorded in all cases, the number of fluoroscopy during the operation, and the varus/valgus, anteversion/reversion angle after the operation were measured. All measurement data were expressed by means ± SD, and Student's t test was used to examine differences between groups. The chi square test or Fisher's precise test was used to compare the counting data of the two groups. Result All PSI matched well with the corresponding tibia bone defect, and were consistent with the preoperative plan and intraoperative operation. The affected limb had a good reduction effect. The operation time from the beginning of PSI installation to the completion of Ilizarov ring fixator installation was 31.33 ± 3.20 min, while that in the traditional operation group was 64.10 ± 6.14 min (p < 0.001). The times of fluoroscopy in the PSI group during operation was 10.11 ± 1.83, and that in the traditional operation group was 27.60 ± 5.82. The reduction effect of tibia in PSI group was better than that in traditional operation group, with the average angle of PSI group is 1.21 ± 0.24°, and that of traditional operation group is 2.36 ± 0.33° (p < 0.001). Conclusion The PSI simplifies procedures, reduces the difficulty of the operation, improves the accuracy of the operation, and provides a good initial position when used in distraction osteogenesis to treat the tibial defects.
Collapse
Affiliation(s)
- Hao Zheng
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Lili Wang
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Wenbo Jiang
- Clinical and Translational Research Center for 3D Printing Technology, Shanghai Ninth People’ s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ruiqing Qin
- Clinical and Translational Research Center for 3D Printing Technology, Shanghai Ninth People’ s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zhiyu Zhang
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Zhuqing Jia
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Jian Zhang
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Yong Liu
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China,Correspondence: Xuejian Gao Yong Liu
| | - Xuejian Gao
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China,Correspondence: Xuejian Gao Yong Liu
| |
Collapse
|
6
|
van Es LJM, van der Plaat LW, Sierevelt IN, Hoornenborg D, Haverkamp D. Long-term Follow-up of 254 Ceramic Coated Implant (CCI) Evolution Total Ankle Replacements. Foot Ankle Int 2022; 43:1285-1294. [PMID: 35786056 DOI: 10.1177/10711007221108084] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The ceramic coated implant (CCI) Evolution was a third-generation implant design used in approximately 2000 total ankle replacements (TARs) between 2003 and 2016. Because this implant was abandoned, long-term follow-up studies are lacking. METHODS All patients undergoing TAR using a CCI prosthesis between 2004 and 2012 were included for analysis. Preoperatively the tibiotalar alignment was measured, and postoperatively the patients were followed up clinically, with radiographs and by questionnaire. The primary outcome was implant survival at 10 years of follow-up. Implant survival was also compared for (1) inflammatory joint disease vs noninflammatory joint disease and (2) preoperative tibiotalar neutral vs varus or valgus alignment. The secondary outcomes were complications, reoperations, and function (assessed by patient-reported outcome measures). RESULTS Two hundred fifty-four TARs were performed in 237 patients. Two hundred twelve additional procedures were performed to achieve stable ankles. At 10-year follow-up, the survival was 67.5%, with an average time to revision of 4.5 years. The 10-year survival of the inflammatory joint disease group was 76.8% and of the noninflammatory joint group 63.1% (P = .44). In 248 TARs, the preoperative tibiotalar alignment was measured; (62% neutral, 25% varus, and 13% valgus), these showed 10-year survival rates of 74.7%, 48.2%, and 68.9% respectively (P = .07). The complication rate was 54%; 37% of patients underwent reoperation. At a mean of 8.5 years, postoperative satisfaction scored an average of 7.0 (SD 2.26) on a 0- to 10-point numeric rating scale. The mean Foot and Ankle Ability Measure sports subscore was 24.7, the mean Foot and Ankle Outcome Score (FAOS) sports subscore was 42.8, and the mean 36-Item Short Form Health Survey score was 40.0. Regarding daily activities, the mean FAOS was 81.0. CONCLUSION This is currently the sole study reporting the long-term results of the CCI prosthesis. The survival and functional outcomes were inferior to other third-generation mobile-bearing ankle implants.
Collapse
Affiliation(s)
- Laurian J M van Es
- Department of Orthopedic Surgery, Noordwest Ziekenhuisgroep, Alkmaar, the Netherlands.,Specilized Centre for Orthopeadic Research & Education (SCORE), Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, the Netherlands
| | | | - Inger N Sierevelt
- Specilized Centre for Orthopeadic Research & Education (SCORE), Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, the Netherlands.,Department of Orthopedic Surgery, Spaarne Gasthuis Academy, Hoofddorp, the Netherlands
| | - Daniel Hoornenborg
- Specilized Centre for Orthopeadic Research & Education (SCORE), Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, the Netherlands
| | - Daniel Haverkamp
- Specilized Centre for Orthopeadic Research & Education (SCORE), Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, the Netherlands
| |
Collapse
|
7
|
Hernigou P, Scarlat MM. Ankle and foot surgery: from arthrodesis to arthroplasty, three dimensional printing, sensors, artificial intelligence, machine learning technology, digital twins, and cell therapy. INTERNATIONAL ORTHOPAEDICS 2021; 45:2173-2176. [PMID: 34448029 PMCID: PMC8390078 DOI: 10.1007/s00264-021-05191-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|