Zhou LC, Hong WJ, Cao MB, Zeng L, Peng T, Li XR, Zhu GS, Luo SK. Morphological Aesthetics Assessment of the Predicted 3D Simulation Results and the Actual Results of Breast Augmentation. Aesthetic Plast Surg 2024; 48:568-579. [PMID: 37608189 DOI: 10.1007/s00266-023-03597-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 08/07/2023] [Indexed: 08/24/2023]
Abstract
BACKGROUND Although three-dimensional (3D) simulations are becoming more common in preoperative breast augmentation planning, this does not necessarily imply that the simulated results are highly accurate. OBJECTIVES We aimed to evaluate the accuracy of the 3D simulation technique by comparing the differences in breast morphology between the 3D prediction model and the actual results. METHODS The simulation and actual postoperative results of 103 patients who underwent breast augmentation were analyzed retrospectively. Therefore, a 3D model was created, and the parameters of line spacing, nipple position, breast projection, surface area, and volume were evaluated. Furthermore, consider the difference in chest circumferences and breast volume. RESULTS In comparison with the simulation results, the actual results had a mean increase in the nipple to the inframammary fold (N-IMF) of 0.3 cm (P < 0.05) and a mean increase in basal breast width (BW) of 0.3 cm (P < 0.001), a difference that was not statistically significant in patients with larger breast volumes. There was a significant difference in the mean upper and lower breast volume distribution between simulated and actual breasts (upper pole 52.9% vs. 49.2%, P < 0.05, and lower pole 47.1% vs. 50.8%, P < 0.001). However, it was not statistically significant in patients with larger chest circumferences. CONCLUSIONS Our study shows that 3D simulation has uncertainties related to the patient's chest circumference and breast volume. Therefore, these two critical factors must be considered when using simulation assessment in preoperative planning. LEVEL OF EVIDENCE III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Collapse
Affiliation(s)
- Ling-Cong Zhou
- The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou, Guangdong, China
| | - Wei-Jin Hong
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Mi-Bu Cao
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Li Zeng
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Tong Peng
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Xin-Rui Li
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Guo-Sheng Zhu
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Sheng-Kang Luo
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China.
| |
Collapse
|
2
|
Campiglio G. Invited Discussion on "Three-Dimensional Evaluation of Results After Dual Plane Breast Augmentation With and Without Internal Suture Mastopexy" by Xin Rui Li et al. Aesthetic Plast Surg 2023; 47:1312-1314. [PMID: 36725699 DOI: 10.1007/s00266-023-03262-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 02/03/2023]
Affiliation(s)
- Gianluca Campiglio
- Private Practice, Milan, Italy.
- Campiglio Plastic Surgery Center, Milan, Italy.
| |
Collapse
|
3
|
Li XR, Zeng L, Hong WJ, Li ZH, Lin FC, Zhang YL, Luo SK. Three-dimensional Evaluation of Results After Dual-Plane Breast Augmentation with and Without Internal Suture Mastopexy. Aesthetic Plast Surg 2023; 47:1303-1311. [PMID: 36454327 DOI: 10.1007/s00266-022-03200-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Accepted: 11/16/2022] [Indexed: 12/05/2022]
Abstract
BACKGROUND In patients with breast atrophy and ptosis, it is necessary to correct both problems simultaneously. This study aimed to analyze breast morphological changes with a three-dimensional (3D) scanning technique to demonstrate the improvement effect of dual-plane breast augmentation combined with internal suture mastopexy. METHODS 3D breast surface scans were performed preoperatively and postoperatively in 24 patients (n = 35 breasts) undergoing internal suture mastopexy combined with prosthetic augmentation through the periareolar approach and 24 patients (48 breasts) undergoing simple dual-plane breast augmentation. Changes in linear distance, breast volume and volume distribution, breast projection, and nipple position were analyzed to assess the breast morphology. RESULTS Compared with simple breast augmentation, augmentation combined with internal suture mastopexy was associated with a higher upper pole volume increase and greater medial and upward nipple displacement. After the surgery, the upper pole volume increased by an average of 10.6% in combined augmentation group and decreased by an average of 2.2% in the simple breast augmentation group. The measured breast projections were 24.8 ± 2.2% lower than expected in the combined group and 23.1 ± 4.1% lower than expected in the simple group, based on implant parameters recorded by the manufacturer. The nipple moved 0.2 ± 0.5 cm laterally, 1.6 ± 0.6 cm upward, and 2.8 ± 0.7 cm anteriorly in the combined group and 0.9 ± 0.5 cm laterally, 0.7 ± 0.6 cm upward, and 3.0 ± 0.6 cm anteriorly in the simple group. CONCLUSIONS Dual-plane breast augmentation in addition to internal suture mastopexy appears to reposition breast tissue from the lower pole to fill in the deficient upper breast, pull the nipple medially and superiorly, and ultimately correct mild to moderate breast ptosis. LEVEL OF EVIDENCE III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Collapse
Affiliation(s)
- Xin-Rui Li
- Second School of Clinical Medicine, Southern Medical University, Guangzhou, Guangdong, China
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Li Zeng
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Wei-Jin Hong
- Second School of Clinical Medicine, Southern Medical University, Guangzhou, Guangdong, China
| | - Zhen-Hao Li
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
- Jinan University, Guangzhou, Guangdong, China
| | - Fu-Chuan Lin
- Second School of Clinical Medicine, Southern Medical University, Guangzhou, Guangdong, China
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - You-Liang Zhang
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China
| | - Sheng-Kang Luo
- Second School of Clinical Medicine, Southern Medical University, Guangzhou, Guangdong, China.
- Department of Plastic and Reconstructive Surgery, Guangdong Second Provincial General Hospital, 466 Middle Xin Gang Road, Guangzhou, 510317, Guangdong, China.
- Jinan University, Guangzhou, Guangdong, China.
| |
Collapse
|
4
|
Hammond DC. Invited Discussion on: Internal Mastopexy: A Novel Method of Filling the Upper Poles During Dual-Plane Breast Augmentation Through Periareolar Incision. Aesthetic Plast Surg 2021; 45:1476-1477. [PMID: 34100105 DOI: 10.1007/s00266-020-02106-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 12/17/2020] [Indexed: 10/21/2022]
|