Matsuda H, Oka Y, Takatsu S, Miyazaki M. Anesthetic effect of ultrasound-guided block of the musculocutaneous nerve during endovascular treatment of dysfunctional radiocephalic arteriovenous fistulas. J Vasc Access 2023; 24:1314-1321. [PMID: 35343310 DOI: 10.1177/11297298221075178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Delivering requisite and minimal anesthesia for endovascular treatment (EVT) of dysfunctional arteriovenous fistulas (AVFs) under the target nerve block can achieve reasonable analgesia. We evaluated the anesthetic efficacy of ultrasound (US)-guided selective block of the musculocutaneous nerve (MCN) during the EVT of runoff venous strictures in the forearm through the radiocephalic (RC)-AVF at the wrist or the anatomical snuff box and analyzed the factors inhibiting the analgesia achieved under the MCN block. METHODS We enrolled 30 adult patients undergoing hemodialysis who had received 78 EVT sessions in an outpatient clinic mainly for long and/or multiple outflow-venous strictures in the forearm under US-guided blocks of the MCN, which provides sensory innervation to the anterolateral forearm where the cephalic vein courses. We assessed patients' pain during balloon dilations using the Wong-Baker FACES® Pain Rating Scale (WBFRS) and evaluated the factors increasing the pain (WBFRS score ⩾4), including patient characteristics, dilated strictures, additional nerve blocks, and types of balloon catheters. RESULTS In 25 EVT sessions (32.1%) out of 78 sessions, patients complained of stronger pain (WBFRS score ⩾4), while in the other 53 sessions (67.9%), presented with no pain and slight pain (WBFRS score = 0 or 2). Univariate analysis clarified that dilation of the AVF anastomosis, presence of dilated stenosis >4 cm, and a single block of the MCN or its sensory terminal significantly triggered more pain (p < 0.05). Consequently, multivariate analysis of all the factors with p < 0.1 in the univariate analysis, including multiple dilated stenosis sites, demonstrated that dilation of the AVF anastomosis significantly caused severe pain despite the anesthesia of the MCN block (p < 0.05). CONCLUSION US-guided selective block of the MCN could be a leading anesthetic option for EVT for multiple long stenoses of the cephalic vein draining through the RC-AVF in the wrist or anatomical snuff box.
Collapse
Affiliation(s)
- Hiroaki Matsuda
- Department of Surgery, Saiwaicho Memorial Hospital, Okayama, Japan
| | - Yoshinari Oka
- Department of Surgery, Saiwaicho Memorial Hospital, Okayama, Japan
| | - Shigeko Takatsu
- Department of Internal Medicine, Saiwaicho Memorial Hospital, Okayama, Japan
| | - Masashi Miyazaki
- Department of Surgery, Saiwaicho Memorial Hospital, Okayama, Japan
| |
Collapse
|
2
|
Tan Z, Chan SXJM, Da Zhuang K, Urlings T, Leong S, Chua JME, Patel A, Irani FG, Chandramohan S, Tay KH, Damodharan K, Lo RHG, Venkatanarasimha N, Too CW, Tan BS, Tan CS, Chong TT, Win HH, Rahman ASBA, Sulaiman MSB, Gogna A. Recurrent Stenoses in Arteriovenous Fistula (AVF) for Dialysis Access: cuttIng ballooN angioplaSTy combined wITh paclitaxel drUg-coaTed balloon angioplasty, an observatIONal study (INSTITUTION Study). Cardiovasc Intervent Radiol 2022; 45:646-653. [DOI: 10.1007/s00270-021-03030-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 10/26/2021] [Indexed: 11/30/2022]
|
3
|
Pirozzi N, De Alexandris L, Fazzari L, Scrivano J, Pirozzi R, Menè P. Cubital vein transposition for a distal radiocephalic fistula complicated by outflow obstruction. J Vasc Access 2019; 21:520-523. [DOI: 10.1177/1129729819890472] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Introduction: Outflow stenosis is a frequent complication of vascular access for hemodialysis. It may cause increased pressure within the angioaccess along with reduced blood flow. Elective treatment is percutaneous transluminal angioplasty; however, when a long occlusion (>2 cm) occurs, success and mid-term patency of endovascular treatment are uncertain. We describe a case series of patients with long occlusion of elbow outflow complicating an otherwise excellent forearm arteriovenous fistula, treated by a bypass across the elbow through cubital vein transposition. Patients and methods: Six consecutive patients have been treated between 2015 and 2017; all were referred because of either low flow, increased venous pressure, excessive bleeding time, or recirculation and were examined by duplex ultrasound. A total of 83% of patients showed associated thrombosis within the access. All procedures were performed under loco-regional anesthesia and preventive hemostasis. Surgical thrombectomy was also performed when needed. Results: Immediate success was obtained in all but two patients converted in veno-venous polytetrafluoroethylene bypass. Post-operative blood flow increased from 316 to 878 mL/min. All patients were dialyzed through the forearm access immediately the day after surgery, without the need for central vein catheter. Overall, 75% of patients needed a percutaneous transluminal angioplasty of the veno-venous anastomosis within 6 months. Primary and secondary patency at 12 and 24 months were 25%–0% and 100%–100%, respectively. Conclusion: Outflow reconstruction through the elbow bypass by cubital vein transposition is a valuable resource to rescue radiocephalic arteriovenous fistula complicated by outflow obstruction, avoiding the use of an interim central vein catheter. Endovascular treatment is vital to maintain functional patency in the mid- and long term.
Collapse
Affiliation(s)
- Nicola Pirozzi
- Nephrology Unit, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Lorenzo De Alexandris
- Nephrology Unit, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | | | | | | | - Paolo Menè
- Nephrology Unit, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
4
|
Holden A, Hill AA, Buckley B, Connor B, Semple D, Merrilees S, Marsh E, Alfahad A, Iyer R. Clinical Evaluation of the Cook Advance Enforcer 35 Focal-Force PTA Balloon Catheter for Treatment of Hemodialysis Fistula Stenoses: A Feasibility Study. J Vasc Interv Radiol 2018; 30:61-68. [PMID: 30527650 DOI: 10.1016/j.jvir.2018.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Revised: 08/14/2018] [Accepted: 08/15/2018] [Indexed: 11/24/2022] Open
Abstract
PURPOSE A prospective, single-center, single-arm feasibility study evaluated procedural and short-term performance of the Advance Enforcer 35 focal-force percutaneous transluminal angioplasty (PTA) balloon catheter in treating stenoses of mature native arteriovenous (AV) hemodialysis access circuits. MATERIALS AND METHODS Twenty-eight patients undergoing treatment for stenosis of a mature native AV hemodialysis access circuit were enrolled at a single institution. Angiographic assessments of the study lesion were required at baseline and after the procedure. Adjunctive procedures for significant residual stenosis were permitted, and patients had clinical and imaging follow-up for as long as 6 months. RESULTS Treatment with the study balloon was effective in reducing the average percent diameter stenosis of the treated lesion from 66.3% (range, 43.8%-93.3%) before the procedure to 23.7% (range, -6.7% to 51.4%) after the procedure. The average inflation pressure required was 12.3 atm. Only 1 patient required an adjunctive procedure, and all patients could resume normal dialysis following the study procedure. At 3 months, 62.0% of study lesions remained patent, and the 6-month patency rate was 25.1%. Two adverse events associated with the study procedure were reported: access-site hematoma and forearm pain (3.6% each). CONCLUSIONS The results demonstrate safety of the study balloon in treating AV access stenosis. Nominal-diameter angioplasty was achieved at relatively low pressure in most study patients without the use of adjunctive procedures, and resumption of normal dialysis was achieved for all patients.
Collapse
Affiliation(s)
- Andrew Holden
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand.
| | - Andrew A Hill
- Department of Vascular Surgery, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Brendan Buckley
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Brigid Connor
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - David Semple
- Department of Renal Medicine, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Stephen Merrilees
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Emma Marsh
- Department of Renal Medicine, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Aws Alfahad
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | | |
Collapse
|
5
|
Goya S, Wada T, Shimada K, Uemura A, Tanaka R. Combined cutting balloon and conventional balloon angioplasty in a dog with supravalvular pulmonary stenosis. J Vet Med Sci 2018; 80:1754-1757. [PMID: 30232302 PMCID: PMC6261821 DOI: 10.1292/jvms.18-0060] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
A 7-year-old Miniature Schnauzer presented with exercise intolerance and easy fatigability. Echocardiography revealed the presence of supravalvular pulmonary stenosis. The peak velocity
through the stenosis was 6.4 m/sec, and the interventricular septum was flattened. Cutting balloon angioplasty was designed for the treatment of coronary artery stenosis, which was resistant
to conventional balloon angioplasty. Accordingly, the dog underwent cutting balloon angioplasty and conventional balloon dilation. One month after treatment, it showed neither exercise
intolerance nor easy fatigability. The ventricular septum flattening disappeared. Five months later, the dog showed an increase in activity. Two years later, the peak velocity through the
stenosis decreased to 4.4 m/sec. Neither clinical symptoms nor restenosis was observed. Thus, supravalvular pulmonary stenosis was successfully treated using this combination method. The
present case showed that combined cutting balloon and conventional balloon angioplasty is a useful and minimally invasive treatment for supravalvular pulmonary stenosis.
Collapse
Affiliation(s)
- Seijirow Goya
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509, Japan
| | - Tomoki Wada
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509, Japan
| | - Kazumi Shimada
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509, Japan
| | - Akiko Uemura
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509, Japan
| | - Ryou Tanaka
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509, Japan
| |
Collapse
|
6
|
Schmidli J, Widmer MK, Basile C, de Donato G, Gallieni M, Gibbons CP, Haage P, Hamilton G, Hedin U, Kamper L, Lazarides MK, Lindsey B, Mestres G, Pegoraro M, Roy J, Setacci C, Shemesh D, Tordoir JH, van Loon M, ESVS Guidelines Committee, Kolh P, de Borst GJ, Chakfe N, Debus S, Hinchliffe R, Kakkos S, Koncar I, Lindholt J, Naylor R, Vega de Ceniga M, Vermassen F, Verzini F, ESVS Guidelines Reviewers, Mohaupt M, Ricco JB, Roca-Tey R. Editor's Choice – Vascular Access: 2018 Clinical Practice Guidelines of the European Society for Vascular Surgery (ESVS). Eur J Vasc Endovasc Surg 2018; 55:757-818. [DOI: 10.1016/j.ejvs.2018.02.001] [Citation(s) in RCA: 346] [Impact Index Per Article: 57.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
7
|
Heerwagen ST, Lönn L, Schroeder TV, Hansen MA. Cephalic Arch Stenosis in Autogenous Brachiocephalic Hemodialysis Fistulas: Results of Cutting Balloon Angioplasty. J Vasc Access 2018; 11:41-5. [DOI: 10.1177/112972981001100109] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Purpose Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose of this retrospective study was to report outcomes after cutting balloon angioplasty (CBA) of cephalic arch stenosis. Methods In our vascular access database we identified 74 dysfunctional BcFs of which 30 (41%) were caused by cephalic arch stenosis. Seventeen fistulas in 17 patients (13 males and four females; median age 62 yrs; range 52–86) were treated with CBA (June 2005 to January 2008). Twenty-five procedures were performed. In 15 procedures, a cutting balloon was used alone and in 10 procedures CBA was followed by standard or high-pressure balloon angioplasty. Restenosis rates were calculated and patency rates were estimated with the Kaplan-Meier method. Results Primary patency rates (±SEE) at 3, 6, 12 and 15 months were 94% (±6%), 81% (±10%), 38% (±14%) and 22% (±15%), respectively. Assisted primary patency rates (±SEE) at the same intervals were 100% (±0%), 94% (±6%), 77% (±12%) and 63% (±13%), respectively. The mean interval between radiological interventions was 13 months (SD=8) and the mean number of interventions required per patient-year of dialysis was 0.9. Conclusion Treatment of cephalic arch stenosis with CBA did not improve patency compared to published results of conventional PTA, but our results indicate that CBA may lower the frequency of required re-interventions.
Collapse
Affiliation(s)
- Søren T. Heerwagen
- Department of Interventional Radiology, Rigshospitalet, Copenhagen - Denmark
| | - Lars Lönn
- Department of Interventional Radiology, Rigshospitalet and University of Copenhagen, Copenhagen - Denmark
| | - Torben V. Schroeder
- Department of Vascular Surgery, Rigshospitalet and University of Copenhagen, Copenhagen - Denmark
| | - Marc A. Hansen
- Department of Interventional Radiology, Rigshospitalet, Copenhagen - Denmark
| |
Collapse
|
8
|
Thomas M, Nesbitt C, Ghouri M, Hansrani M. Maintenance of Hemodialysis Vascular Access and Prevention of Access Dysfunction: A Review. Ann Vasc Surg 2017; 43:318-327. [DOI: 10.1016/j.avsg.2017.02.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Accepted: 02/28/2017] [Indexed: 01/24/2023]
|
9
|
Dariushnia SR, Walker TG, Silberzweig JE, Annamalai G, Krishnamurthy V, Mitchell JW, Swan TL, Wojak JC, Nikolic B, Midia M. Quality Improvement Guidelines for Percutaneous Image-Guided Management of the Thrombosed or Dysfunctional Dialysis Circuit. J Vasc Interv Radiol 2016; 27:1518-30. [DOI: 10.1016/j.jvir.2016.07.015] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Revised: 07/12/2016] [Accepted: 07/14/2016] [Indexed: 01/20/2023] Open
|
10
|
Hu H, Patel S, Hanisch JJ, Santana JM, Hashimoto T, Bai H, Kudze T, Foster TR, Guo J, Yatsula B, Tsui J, Dardik A. Future research directions to improve fistula maturation and reduce access failure. Semin Vasc Surg 2016; 29:153-171. [PMID: 28779782 DOI: 10.1053/j.semvascsurg.2016.08.005] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
With the increasing prevalence of end-stage renal disease, there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis, but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes in the setting of uremia, systemic inflammation, oxidative stress, and pre-existent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis and development of neointimal hyperplasia that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to neointimal hyperplasia involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure require a multidisciplinary approach involving nephrologists, vascular surgeons, and interventional radiologists, careful patient selection, and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy.
Collapse
Affiliation(s)
- Haidi Hu
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Department of Vascular and Thyroid Surgery, the First Affiliated Hospital of China Medical University, Shenyang, China; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Sandeep Patel
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT; Royal Free Hospital, University College London, London, UK
| | - Jesse J Hanisch
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Jeans M Santana
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Takuya Hashimoto
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Hualong Bai
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Tambudzai Kudze
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Trenton R Foster
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Jianming Guo
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Bogdan Yatsula
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT
| | - Janice Tsui
- Royal Free Hospital, University College London, London, UK
| | - Alan Dardik
- Department of Surgery, Yale University School of Medicine, 10 Amistad Street, Room 437, PO Box 208089, New Haven, CT 06520-8089; Vascular Biology and Therapeutics Program, Yale University, New Haven, CT; VA Connecticut Healthcare System, West Haven, CT.
| |
Collapse
|
11
|
Aftab SA, Tay KH, Irani FG, Gong Lo RH, Gogna A, Haaland B, Tan SG, Chng SP, Pasupathy S, Choong HL, Tan BS. Randomized Clinical Trial of Cutting Balloon Angioplasty versus High-Pressure Balloon Angioplasty in Hemodialysis Arteriovenous Fistula Stenoses Resistant to Conventional Balloon Angioplasty. J Vasc Interv Radiol 2014; 25:190-8. [DOI: 10.1016/j.jvir.2013.10.020] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2012] [Revised: 10/12/2013] [Accepted: 10/14/2013] [Indexed: 11/24/2022] Open
|
12
|
The Role of “Cutting” Balloon Angioplasty for the Treatment of Short Femoral Bifurcation Steno-Obstructive Disease. Cardiovasc Intervent Radiol 2010; 33:921-8. [DOI: 10.1007/s00270-010-9802-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2009] [Accepted: 01/04/2010] [Indexed: 11/27/2022]
|
13
|
Peripheral Stent Placement in Hemodialysis Grafts. Cardiovasc Intervent Radiol 2009; 32:960-6. [DOI: 10.1007/s00270-009-9580-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2008] [Revised: 03/17/2009] [Accepted: 03/19/2009] [Indexed: 10/20/2022]
|
14
|
Peregrin JH, Bürgelová M. Restoration of failed renal graft function after successful angioplasty of pressure-resistant renal artery stenosis using a cutting balloon: a case report. Cardiovasc Intervent Radiol 2008; 32:548-53. [PMID: 18756369 DOI: 10.1007/s00270-008-9420-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2008] [Revised: 07/24/2008] [Accepted: 07/25/2008] [Indexed: 10/21/2022]
Abstract
This study is the report of a 37-year-old male with a transplanted kidney from a 3.5-year-old donor: the graft had two arteries transplanted with an aortic patch to an external iliac artery. Four months after transplantation, the graft function deteriorated, together with the development of hypertension. Stenosis of both graft arteries was detected and the patient was referred for angioplasty. The angiographic result was suboptimal, nevertheless, the graft function improved and was more or less stable (serum creatinine, 160-200 micromol/l) for 4 years, along with persistently difficult-to-control hypertension. Five years after transplantation, the graft function deteriorated again and severe graft artery restenosis was detected. The restenosis did not respond to dilatation, graft function failed, hypertension decompensated, and left ventricular failure developed. The patient required dialysis. A cutting balloon angioplasty opened the artery, and kidney function was restored after a few days: the serum creatinine level dropped to 140-160 micromol/l, and the glomerular filtration rate (creatinine clearance) to 0.65 ml/min/1.73 m(2). The graft function has now been stable for more than 2 years, however, the hypertension is still difficult to control.
Collapse
Affiliation(s)
- J H Peregrin
- Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
| | | |
Collapse
|
15
|
Wu CC, Lin MC, Pu SY, Tsai KC, Wen SC. Comparison of Cutting Balloon versus High-Pressure Balloon Angioplasty for Resistant Venous Stenoses of Native Hemodialysis Fistulas. J Vasc Interv Radiol 2008; 19:877-83. [DOI: 10.1016/j.jvir.2008.02.016] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2007] [Revised: 02/12/2008] [Accepted: 02/22/2008] [Indexed: 11/28/2022] Open
|
16
|
Gupta M, Rajan DK, Tan KT, Sniderman KW, Simons ME. Use of Expanded Polytetrafluoroethylene–covered Nitinol Stents for the Salvage of Dysfunctional Autogenous Hemodialysis Fistulas. J Vasc Interv Radiol 2008; 19:950-4. [DOI: 10.1016/j.jvir.2008.03.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2007] [Revised: 03/05/2008] [Accepted: 03/10/2008] [Indexed: 11/29/2022] Open
|
17
|
Yevzlin AS, Guttormsen B, Chan MR, Gimelli G. How I do it: directional atherectomy for in-stent restenosis of a PTFE arteriovenous graft. Semin Dial 2008; 21:266-8. [PMID: 18248520 DOI: 10.1111/j.1525-139x.2007.00418.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We describe the use of directional atherectomy (DA) to restore patency of a thrombosed polytetrafluoroethylene arteriovenous graft with an in-stent restenosis at the venous anastomosis. Technically, the procedure described is not an atherectomy per se, but rather the removal of fibrosis and intimal hyperplasia with sharp endoluminal dissection. Certainly, the operator must be cautious when performing DA directly adjacent to a previously deployed stent. Nevertheless, our report suggests that there may be a role for DA in the treatment of severe, resistant in-stent stenosis. Further investigation is necessary to evaluate the safety and efficacy of the described technique.
Collapse
Affiliation(s)
- Alexander S Yevzlin
- Section of Nephrology, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
| | | | | | | |
Collapse
|
18
|
Cutting Balloon Angioplasty in Dialysis Fistulas: Let Us Start to Ask the Right Questions. Cardiovasc Intervent Radiol 2007. [DOI: 10.1007/s00270-007-9144-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|