1
|
Tikhvinsky D, Maus M, Lipovka A, Nikitin N, Epifanov R, Volkova I, Mullyadzhanov R, Chupakhin A, Parshin D, Karpenko A. The role of asymmetry and volume of thrombotic masses in the formation of local deformation of the aneurysmal-altered vascular wall: An in vivo study and mathematical modeling. PLoS One 2024; 19:e0301047. [PMID: 38870116 PMCID: PMC11175491 DOI: 10.1371/journal.pone.0301047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 02/27/2024] [Indexed: 06/15/2024] Open
Abstract
Currently, the primary factor indicating the necessity of an operation for an abdominal aortic aneurysm (AAA) is the diameter at its widest part. However, in practice, a large number of aneurysm ruptures occur before reaching a critical size. This means that the mechanics of aneurysm growth and remodeling have not been fully elucidated. This study presents a novel method for assessing the elastic properties of an aneurysm using an ultrasound technique based on tracking the oscillations of the vascular wall as well as the inner border of the thrombus. Twenty nine patients with AAA and eighteen healthy volunteers were considered. The study presents the stratification of a group of patients according to the elastic properties of the aneurysm, depending on the relative volume of intraluminal thrombus masses. Additionally, the neural network analysis of CT angiography images of these patients shows direct (r = 0.664271) correlation with thrombus volume according to ultrasound data, the reliability of the Spearman correlation is p = 0.000215. The use of finite element numerical analysis made it possible to reveal the mechanism of the negative impact on the AAA integrity of an asymmetrically located intraluminal thrombus. The aneurysm itself is considered as a complex structure consisting of a wall, intraluminal thrombus masses, and areas of calcification. When the thrombus occupies > 70% of the lumen of the aneurysm, the deformations of the outer and inner surfaces of the thrombus have different rates, leading to tensile stresses in the thrombus. This poses a risk of its detachment and subsequent thromboembolism or the rupture of the aneurysm wall. This study is the first to provide a mechanistic explanation for the effects of an asymmetrical intraluminal thrombus in an abdominal aortic aneurysm. The obtained results will help develop more accurate risk criteria for AAA rupture using non-invasive conventional diagnostic methods.
Collapse
Affiliation(s)
- Denis Tikhvinsky
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
| | - Maria Maus
- Department of Vascular Pathology and Hybrid Surgery, Meshalkin National Medical Research Center, Novosibirsk, Russia
| | - Anna Lipovka
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
| | - Nikita Nikitin
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
- Department of Vascular Pathology and Hybrid Surgery, Meshalkin National Medical Research Center, Novosibirsk, Russia
| | - Rostislav Epifanov
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
| | - Irina Volkova
- Department of Vascular Pathology and Hybrid Surgery, Meshalkin National Medical Research Center, Novosibirsk, Russia
| | - Rustam Mullyadzhanov
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
- Laboratory of supercomputing and artificial intelligence in energetic technologies, Kutateladze Institute of Thermophysics SB RAS, Novosibirsk, Russia
| | - Alexander Chupakhin
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
| | - Daniil Parshin
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
| | - Andrey Karpenko
- Department of Mathematics and Mechanics, Novosibirsk State University, Novosibirsk, Russia
- Department of Vascular Pathology and Hybrid Surgery, Meshalkin National Medical Research Center, Novosibirsk, Russia
| |
Collapse
|
2
|
S SN, Bhattacharjee A, Saha S. CFD analysis of the hyper-viscous effects on blood flow across abdominal aortic aneurysm in COVID patients: multiphysics approach. Comput Methods Biomech Biomed Engin 2024; 27:570-586. [PMID: 37021363 DOI: 10.1080/10255842.2023.2194474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 03/19/2023] [Indexed: 04/07/2023]
Abstract
Recent research has shown that individuals suffering from COVID-19 are accommodating an elevated level of blood viscosity due to the morphological changes in blood cells. As viscosity is a major flow parameter influencing the flow across a stenosis or an aneurysm, the examination of the significance of hyperviscosity in COVID patients is imperative in arterial pathologies. In this research, we have considered a patient-specific case in which the aneurysm is located along the abdominal aortal walls. Recent research on the side effects of COVID-19 voiced out the various effects on the circulatory system of humans. Also, as abdominal aneurysms exist very often among individuals, causing the death of 150-200 million every year, the hyper-viscous effects of blood on the flow across the diseased aorta are explored by considering the elevated viscosity levels. In vitro explorations contribute considerably to the clinical methods and treatments to be regarded. The objective of the present inquest is to research the flow field in aneurysmatic-COVID-affected patients considering the elastic nature of vessel walls, using the arbitrary Lagrangian-Eulerian approach. The study supports the various clinical findings that voiced the detrimental effects associated with blood hyperviscosity. The simulation results obtained, by solving the fluid mechanics' equations coupled with the solid mechanics' equations, employing a FEM solver suggest that the elevated stress imparted by the hyper-viscous flows on the walls of the aneurysmal aorta can trigger the fastening of the aneurysmal sac enlargement or rupture.
Collapse
Affiliation(s)
- Shankar Narayan S
- Department of Mathematics and Statistics, Ramaiah University of Applied Sciences, Bengaluru, India
- Department of Mathematics, Dayananda Sagar University, Bengaluru, India
| | | | - Sunanda Saha
- Department of Mathematics, Vellore Institute of Technology, Vellore, India
| |
Collapse
|
3
|
Wang L, Jiang X, Zhang K, Chen K, Wu P, Li X. A hemodynamic analysis of energy loss in abdominal aortic aneurysm using three-dimension idealized model. Front Physiol 2024; 15:1330848. [PMID: 38312315 PMCID: PMC10834748 DOI: 10.3389/fphys.2024.1330848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/05/2024] [Indexed: 02/06/2024] Open
Abstract
Objective: The aim of this study is to perform specific hemodynamic simulations of idealized abdominal aortic aneurysm (AAA) models with different diameters, curvatures and eccentricities and evaluate the risk of thrombosis and aneurysm rupture. Methods: Nine idealized AAA models with different diameters (3 cm or 5 cm), curvatures (0° or 30°) and eccentricities (centered on or tangent to the aorta), as well as a normal model, were constructed using commercial software (Solidworks; Dassault Systemes S.A, Suresnes, France). Hemodynamic simulations were conducted with the same time-varying volumetric flow rate extracted from the literature and 3-element Windkessel model (3 EWM) boundary conditions were applied at the aortic outlet. Several hemodynamic parameters such as time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), endothelial cell activation potential (ECAP) and energy loss (EL) were obtained to evaluate the risk of thrombosis and aneurysm rupture under different conditions. Results: Simulation results showed that the proportion of low TAWSS region and high OSI region increases with the rising of aneurysm diameter, whereas decreases in the curvature and eccentric models of the corresponding diameters, with the 5 cm normal model having the largest low TAWSS region (68.5%) and high OSI region (40%). Similar to the results of TAWSS and OSI, the high ECAP and high RRT areas were largest in the 5 cm normal model, with the highest wall-averaged value (RRT: 5.18 s, ECAP: 4.36 Pa-1). Differently, the increase of aneurysm diameter, curvature, and eccentricity all lead to the increase of mean flow EL and turbulent EL, such that the highest mean flow EL (0.82 W · 10-3) and turbulent EL (1.72 W · 10-3) were observed in the eccentric 5 cm model with the bending angle of 30°. Conclusion: Collectively, increases in aneurysm diameter, curvature, and eccentricity all raise mean flow EL and turbulent flow EL, which may aggravate the damage and disturbance of flow in aneurysm. In addition, it can be inferred by conventional parameters (TAWSS, OSI, RRT and ECAP) that the increase of aneurysm diameter may raise the risk of thrombosis, whereas the curvature and eccentricity appeared to have a protective effect against thrombosis.
Collapse
Affiliation(s)
- Lulu Wang
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
| | - Xudong Jiang
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
| | - Kejia Zhang
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Kai Chen
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Peng Wu
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, China
| | - Xiaoqiang Li
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
| |
Collapse
|
4
|
Vaitėnas G, Mosenko V, Račytė A, Medelis K, Skrebūnas A, Baltrūnas T. Abdominal Aortic Aneurysm Diameter versus Volume: A Systematic Review. Biomedicines 2023; 11:biomedicines11030941. [PMID: 36979920 PMCID: PMC10046268 DOI: 10.3390/biomedicines11030941] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/05/2023] [Accepted: 03/16/2023] [Indexed: 03/30/2023] Open
Abstract
Recently, AAA volume measurement has been proposed as a potentially valuable surveillance method in situations when diameter measurement might fail. OBJECTIVE The aim of this systematic review was to analyze the results of previous studies comparing AAA diameter and volume measurements. METHODS A systematic search in PubMed, Cochrane, and EMBASE databases was performed to identify studies investigating the use of diameter and volume measurements in AAA diagnosis and prognosis in English, German, and Russian, published until December 2022. The manuscripts were reviewed by three researchers and scored on the quality of the research using MINORS criteria. RESULTS After screening 752 manuscripts, 19 studies (n = 1690) were included. The majority (n = 17) of the manuscripts appeared to favor volume. It is, however, important to highlight the heterogeneity of methodologies and lack of standardized protocol for measuring both volume and diameter in the included studies, which hindered the interpretation of the results. CONCLUSIONS The clinical relevance of abdominal aortic aneurysm volume measurement is still unclear, although studies show favorable and promising results for volumetric changes in AAA, especially in follow-up after EVAR.
Collapse
Affiliation(s)
| | - Valerija Mosenko
- Faculty of Medicine, Vilnius University, 01513 Vilnius, Lithuania
| | - Austėja Račytė
- Faculty of Medicine, Vilnius University, 01513 Vilnius, Lithuania
| | - Karolis Medelis
- Center of Vascular and Endovascular Surgery, Vilnius University Hospital Santaros Klinikos, 08410 Vilnius, Lithuania
| | | | - Tomas Baltrūnas
- Faculty of Medicine, Vilnius University, 01513 Vilnius, Lithuania
| |
Collapse
|
5
|
Tzirakis K, Kontopodis N, Kehagias E, Ioannou CV. Effect of Sac Asymmetry, Neck and Iliac Angle on the Hemodynamic Behavior of Idealized Abdominal Aortic Aneurysm Geometries. Ann Vasc Surg 2023:S0890-5096(23)00126-7. [PMID: 36868463 DOI: 10.1016/j.avsg.2023.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 02/14/2023] [Indexed: 03/05/2023]
Abstract
BACKGROUND Abdominal aortic aneurysms (AAAs) are currently treated based on the universal maximum diameter criterion, but other geometric variables may play a role in the risk of rupture. The hemodynamic environment inside the AAA sac has been shown to interact with several biologic processes which can affect prognosis. AAA geometric configuration has a significant impact in the hemodynamic conditions that develop, which has only been recently realized, with implications for rupture risk estimations. We aim to perform a parametric study to evaluate the effect of aortic neck angulation, angle between the iliac arteries, and sac asymmetry (SA) on the hemodynamic variables of AAAs. METHODS This study uses idealized AAA models and it is parametrized in terms of 3 quantities as follows: the neck angle, φ (°), iliac angle, θ (°), and SA (%), each of which accepts 3 different values, specifically φ = (0°, 30°, 60°), θ = (40°, 60°, 80°), and SA = (S, °SS, °OS), where the SA can either be on the same side with respect to neck (SS) or on the opposite side (OS). Time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and the velocity profile are calculated for different geometric configurations, while the percentage of the total surface area under thrombogenic conditions, using thresholds previously reported in the literature, is also recorded. RESULTS In case of an angulated neck and a higher angle between iliac arteries, favorable hemodynamic conditions are predicted with higher TAWSS and lower OSI and RRT values. The area under thrombogenic conditions reduces by 16-46% as the neck angle increases from 0° to 60°, depending on the hemodynamic variable under consideration. The effect of iliac angulation is present but less pronounced with 2.5-7.5% change between the lower and the higher angle. The effect of SA seems to be significant for OSI, with a nonsymmetrical configuration being hemodynamically favorable, which in the presence of an angulated neck is more pronounced for the OS outline. CONCLUSIONS Favorable hemodynamic conditions develop inside the sac of idealized AAAs with increasing neck and iliac angles. Regarding the SA parameter, asymmetrical configurations most often appear advantageous. Concerning the velocity profile the triplet (φ, θ, SA) may affect outcomes under certain conditions and thus should be taken into account when parametrizing the geometric characteristics of AAAs.
Collapse
Affiliation(s)
- Konstantinos Tzirakis
- Department of Mechanical Engineering, Hellenic Mediterranean University, Heraklion, Crete, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Department, Medical School, University of Crete, Heraklion, Crete, Greece.
| | - Elias Kehagias
- Interventional Radiology Unit, Department of Medical Imaging, Medical School, University of Crete, Heraklion, Crete, Greece
| | - Christos V Ioannou
- Vascular Surgery Department, Medical School, University of Crete, Heraklion, Crete, Greece
| |
Collapse
|
6
|
Mutlu O, Salman HE, Al-Thani H, El-Menyar A, Qidwai UA, Yalcin HC. How does hemodynamics affect rupture tissue mechanics in abdominal aortic aneurysm: Focus on wall shear stress derived parameters, time-averaged wall shear stress, oscillatory shear index, endothelial cell activation potential, and relative residence time. Comput Biol Med 2023; 154:106609. [PMID: 36724610 DOI: 10.1016/j.compbiomed.2023.106609] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/19/2023] [Accepted: 01/22/2023] [Indexed: 01/24/2023]
Abstract
An abdominal aortic aneurysm (AAA) is a critical health condition with a risk of rupture, where the diameter of the aorta enlarges more than 50% of its normal diameter. The incidence rate of AAA has increased worldwide. Currently, about three out of every 100,000 people have aortic diseases. The diameter and geometry of AAAs influence the hemodynamic forces exerted on the arterial wall. Therefore, a reliable assessment of hemodynamics is crucial for predicting the rupture risk. Wall shear stress (WSS) is an important metric to define the level of the frictional force on the AAA wall. Excessive levels of WSS deteriorate the remodeling mechanism of the arteries and lead to abnormal conditions. At this point, WSS-related hemodynamic parameters, such as time-averaged WSS (TAWSS), oscillatory shear index (OSI), endothelial cell activation potential (ECAP), and relative residence time (RRT) provide important information to evaluate the shear environment on the AAA wall in detail. Calculation of these parameters is not straightforward and requires a physical understanding of what they represent. In addition, computational fluid dynamics (CFD) solvers do not readily calculate these parameters when hemodynamics is simulated. This review aims to explain the WSS-derived parameters focusing on how these represent different characteristics of disturbed hemodynamics. A representative case is presented for spatial and temporal formulation that would be useful for interested researchers for practical calculations. Finally, recent hemodynamics investigations relating WSS-related parameters with AAA rupture risk assessment are presented. This review will be useful to understand the physical representation of WSS-related parameters in cardiovascular flows and how they can be calculated practically for AAA investigations.
Collapse
Affiliation(s)
- Onur Mutlu
- Biomedical Research Center, Qatar University, Doha, Qatar
| | - Huseyin Enes Salman
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| | - Hassan Al-Thani
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha, Qatar
| | - Ayman El-Menyar
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha, Qatar; Clinical Medicine, Weill Cornell Medical College, Doha, Qatar
| | - Uvais Ahmed Qidwai
- Department of Computer Science Engineering, Qatar University, Doha, Qatar
| | | |
Collapse
|