1
|
Ding C, Chang JK, Lin CC, Wu YJ, Hsieh KS. Efficacy and Safety of Transthoracic Echocardiography Alone in Transcatheter Closure of Secundum-Type Atrial Septal Defects in Adults. Echocardiography 2015; 33:579-85. [PMID: 26522626 DOI: 10.1111/echo.13106] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND On-site transthoracic echocardiography (TTE) to guide the transcutaneous closure of secundum-type atrial septal defects (ASDs) in the catheterization laboratory remains unclear, especially in adults. METHODS Between 2005 and 2012, a total of 82 adults underwent transcutaneous closure of ASDs. The initial 15 cases underwent the procedure with both on-site transesophageal echocardiography (TEE) and TTE monitoring. Since January 2008, a total of 67 patients underwent on-site TTE alone to guide the procedure. RESULTS Among the 82 adult patients who underwent a transcutaneous closure of the secundum-type ASD procedure, all had successful closure of the defects, and no periprocedural adverse complications occurred. No statistical significance was observed in the successful complete shunt closure rate between the TEE plus TTE and TTE groups during sequential follow-up (postprocedure 24 hour [87% vs. 92%],1 month [93% vs. 95%], 3 month [93% vs. 97%], and 12 month [93% vs. 97%], P > 0.05, respectively) nor was a significant difference observed between the two groups, including decreased right ventricular dimension (29.5 ± 3.3 vs. 32.0 ± 4.9 mm, 26.5 ± 3.0 vs. 28.7 ± 4.6 mm, 26.2 ± 3.1 vs. 28.2 ± 4.8 mm, and 25.6 ± 2.8 vs. 27.7 ± 4.7 mm, P > 0.05, respectively) or increased left ventricular end-diastolic dimension (41.1 ± 2.0 vs. 42.6 ± 3.0 mm, 44.3 ± 2.7 vs. 45.5 ± 3.1 mm, 44.2 ± 2.8 vs. 45.4 ± 3.1 mm, 44.9 ± 2.7 vs. 45.8 ± 2.6 mm, P > 0.05, respectively) before the procedure, and at the 3-, 6-, and 12-month follow-up evaluations. CONCLUSION This study showed that TTE guidance alone may be considered efficacious and safe as TEE during a transcutaneous ASD occlusion procedure in select adults.
Collapse
Affiliation(s)
- Cheng Ding
- State Key Laboratory of Cardiovascular Disease, Department of Cardiology, Cardiovascular Institute, Fuwai Hospital and National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jia-Kan Chang
- Department of Pediatrics, Cheng-Hsin General Hospital, Taipei, Taiwan
| | - Chang-Chyi Lin
- Division of Cardiology, Department of Internal Medicine, Cheng-Hsin General Hospital, Taipei, Taiwan
| | - Yong-Jian Wu
- State Key Laboratory of Cardiovascular Disease, Department of Cardiology, Cardiovascular Institute, Fuwai Hospital and National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Kai-Sheng Hsieh
- Department of Pediatrics, Kaohsiung Chang-Gung Memorial Hospital, Kaohsiung, Taiwan
| |
Collapse
|
2
|
Medford BA, Taggart NW, Cabalka AK, Cetta F, Reeder GS, Hagler DJ, Johnson JN. Intracardiac echocardiography during atrial septal defect and patent foramen ovale device closure in pediatric and adolescent patients. J Am Soc Echocardiogr 2014; 27:984-90. [PMID: 24998516 DOI: 10.1016/j.echo.2014.05.017] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2013] [Indexed: 11/20/2022]
Abstract
BACKGROUND Intracardiac echocardiography (ICE) is commonly used during interventional cardiac catheterization in adults, but data regarding the use of ICE in children are limited. There are no data available comparing the effectiveness of preprocedural transthoracic echocardiography (TTE) with that of intraprocedural ICE in predicting atrial septal defect (ASD) size and rim adequacy for percutaneous closure in a pediatric population. The objectives of this study were to describe the investigators' experience using ICE in pediatric and adolescent patients and to compare the effectiveness of preprocedural TTE with that of ICE in predicting ASD size and rim adequacy for percutaneous closure. METHODS In this retrospective study, all cases in which ICE was used during ASD or patent foramen ovale closure in patients ≤21 years of age at a single institution from January 2002 through October 2013 were reviewed. All studies were performed using the Acuson AcuNav ICE system. RESULTS One hundred fifteen patients (65 female; mean age, 12 ± 6 years; range, 10 months to 21 years) were included. All intracardiac echocardiographic studies were performed by the interventional cardiologist performing the catheterization. ICE was used to facilitate ASD closure in 92 patients (81%) and patent foramen ovale closure in 23 (19%). Thirty-eight patients (34%) underwent cardiac catheterization and ICE without general anesthesia. ICE was correlated highly with preprocedural TTE in predicting ASD size (r(2) = 0.76, P < .0001). In nine of 92 patients (9.8%) with ASDs, ICE identified deficient septal rims (n = 8) or complex or multiple ASDs (n = 1) that necessitated surgical closure. There were no major complications. CONCLUSIONS ICE can be performed safely and effectively in a large cohort of children and adolescents undergoing percutaneous device closure. ICE may obviate the need for general anesthesia in some patients and is a reasonable alternative to transesophageal echocardiography for this catheter-based procedure in children. ASD measurements with ICE correlate well with preprocedural measurements on TTE; however, ICE more accurately identifies the absence or deficiency of critical septal rims before device closure.
Collapse
Affiliation(s)
- Beth A Medford
- Department of Pediatrics, Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota.
| | - Nathaniel W Taggart
- Department of Pediatrics, Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota
| | - Allison K Cabalka
- Department of Pediatrics, Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota
| | - Frank Cetta
- Department of Pediatrics, Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota; Department of Medicine, Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Guy S Reeder
- Department of Medicine, Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Donald J Hagler
- Department of Pediatrics, Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota; Department of Medicine, Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Jonathan N Johnson
- Department of Pediatrics, Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
3
|
Hajizeinali A, Sadeghian H, Rezvanfard M, Alidoosti M, Zoroufian A, Volman MA. A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect. Cardiovasc J Afr 2013; 24:161-4. [PMID: 24217162 PMCID: PMC3748448 DOI: 10.5830/cvja-2013-014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2010] [Accepted: 03/18/2013] [Indexed: 11/23/2022] Open
Abstract
Objectives Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. Methods The records of 54 patients who underwent transcatheter ASD closure were reviewed. ASD characteristics and maximum defect diameter were evaluated using preprocedure 2D TEE images. Appropriate device size was determined by the balloon sizing method, which measures the balloon occlusive diameter (BOD) via TEE and fluoroscopy. ASD closure was performed under continuous TEE monitoring using the Amplatzer occluder in all patients. Results The mean of the TEE-derived maximum defect diameter was significantly lower than the mean of the BOD (17.8 ± 4.5 vs 22.1 ± 5.1 mm; p < 0.001) and the mean size of the implanted occluder device (17.8 ± 4.5 vs 23.3 ± 5.1 mm; p < 0.001). However, a good correlation was found between the TEE-derived defect size and the BOD (BOD = 0.898 × TEE defect size + 6.212, R = 0.824; p < 0.001) and between the TEE measurement and the final size of the implanted Amplatzer (device size = 0.928 × TEE defect size + 6.853, R = 0.822; p < 0.001). Conclusions 2D TEE may provide a good equation to predict the BOD or the size of the occluder device; however, further studies are needed to investigate whether it is feasible to perform transcatheter ASD occlusion without balloon sizing.
Collapse
Affiliation(s)
- Alimohammad Hajizeinali
- Interventional Cardiology Department, Tehran Heart Centre, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | | | | | | |
Collapse
|
4
|
Abstract
Patent foramen ovale (PFO) is considered a risk factor for serious clinical syndromes, the most important of which is cryptogenic stroke in the setting of paradoxic embolism. The safety and feasibility of transcatheter PFO closure have been addressed in several studies; this procedure is performed worldwide with excellent results. Variations in the atrial septal configuration and PFO are frequent and have an impact on the technical aspects and success in transcatheter PFO closure. To minimize the rate of complications of percutaneous closure of PFO, patients must be carefully selected on the basis of morphology and location of the interatrial defect.
Collapse
Affiliation(s)
- Eustaquio Onorato
- Clinica Montevergine, Via M. Malzoni, 83013 Mercogliano (Av), Italy; Humanitas Gavazzeni, Bergamo, Italy.
| | - Francesco Casilli
- Emodinamica e Radiologia Cardiovascolare, Policlinico San Donato, Piazza Edmondo Malan-20097 San Donato Milanese, Milano, Italy
| |
Collapse
|
5
|
RIGATELLI GIANLUCA, DELL'AVVOCATA FABIO, CARDAIOLI PAOLO, GIORDAN MASSIMO, DUNG HOTHUONG, NGHIA NGUYENTHUONG, DAGGUBATI RAMESH, NANJIUNDAPPA ARAVINDA. Safety and Long-Term Outcome of Modified Intracardiac Echocardiography-Assisted “No-Balloon” Sizing Technique for Transcatheter Closure of Ostium Secundum Atrial Septal Defect. J Interv Cardiol 2012; 25:628-34. [DOI: 10.1111/j.1540-8183.2012.00755.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
6
|
De Gottardi A, Keller PF, Hadengue A, Giostra E, Spahr L. Transjugular intravascular ultrasound for the evaluation of hepatic vasculature and parenchyma in patients with chronic liver disease. BMC Res Notes 2012; 5:77. [PMID: 22284050 PMCID: PMC3284405 DOI: 10.1186/1756-0500-5-77] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Accepted: 01/27/2012] [Indexed: 01/10/2023] Open
Abstract
Background The evaluation of the hepatic parenchyma in patients with chronic liver disease is important to assess the extension, localization and relationship with adjacent anatomical structures of possible lesions. This is usually performed with conventional abdominal ultrasound, CT-scan or magnetic resonance imaging. In this context, the feasibility and the safety of intravascular ultrasound in the liver have not been assessed yet. Methods We tested the safety and performance of an intracardiac echography (ICE) catheter applied by a transjugular approach into the hepatic veins in patients with chronic liver disease undergoing hepatic hemodynamic measurements. Results Five patients were enrolled in this pilot study. The insertion of the ICE catheter was possible into the right and middle, but not into the left hepatic vein. The position of the ICE was followed using fluoroscopy and external conventional ultrasound. Accurate imaging of focal hepatic parenchymal lesions, Doppler ultrasound of surrounding blood vessels and assessment of liver surface and ascites were achieved without complications. Conclusions This study demonstrated that a diagnostic approach using an ICE device inserted in the hepatic veins is feasible, safe and well tolerated. However, it remains for the moment only an experimental investigative tool. Whether ICE adds further information regarding parenchymal lesions and associated vascular alterations as compared to other techniques, needs additional investigation.
Collapse
Affiliation(s)
- Andrea De Gottardi
- Division of Gastroenterology and Hepatology, University Hospitals and Faculty of Medicine, Geneva, Switzerland.
| | | | | | | | | |
Collapse
|
7
|
Abstract
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter measured in different views was selected as the reference diameter. All procedures were performed under conscious sedation with fluoroscopic and transthoracic echocardiographic guidance. RESULTS Between November, 2006 and December, 2009 a secundum-type atrial septal defect was closed with the Amplatzer septal occluder in 40 patients with transthoracic echocardiographic guidance. The mean age and weight were 7.9 years and 26.9 kilograms, respectively. The mean atrial septal defect diameter was 11.4 millimetres, total septal diameter was 38.5 millimetres, and the mean device diameter and the difference between device and atrial septal defect diameter were 12.6 and 1.2 millimetres, respectively. There were no major complications. The mean follow-up time was 14.8 months. CONCLUSION In selected cases, in which the defects are small and the rims are adequate and transthoracic echocardiography provides high image quality, transthoracic echocardiography can be substituted with transoesophageal echocardiography. The ratio of defect size to total septal diameter can be used as a guide for patient selection; those that have a value of 0.33 or greater can be considered eligible for closure with transthoracic echocardiography. However, transthoracic echocardiography should not be used when there are large or multiple defects, or the rims are thin and soft and the image resolution is inadequate.
Collapse
|
8
|
Quaife RA, Chen MY, Kim M, Klein AJP, Jehle A, Kay J, Groves BM, Carroll JD. Pre-procedural planning for percutaneous atrial septal defect closure: transesophageal echocardiography compared with cardiac computed tomographic angiography. J Cardiovasc Comput Tomogr 2010; 4:330-8. [PMID: 20947043 DOI: 10.1016/j.jcct.2010.08.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2010] [Revised: 07/14/2010] [Accepted: 08/09/2010] [Indexed: 11/15/2022]
Abstract
BACKGROUND The safety and efficacy of percutaneous closure of atrial septal defects (ASDs) is determined by several variables, including defect size, presence of adequate rim tissue, relationship to other cardiac structures, and associated congenital anomalies. OBJECTIVE We sought to determine the accuracy of computed tomographic angiography (CTA) in predicting a defect's size compared with pre-procedural transesophageal echocardiography (TEE) and to the current "gold standard" balloon sizing by intracardiac echocardiography (ICE). METHODS Thirty-five consecutive patients referred for possible percutaneous closure of suspected secundum ASD were evaluated with gated multislice CTA after initial TEE screening. Axial and sagittal image planes of the ASD from the CTA multiplanar reformation (MPR) images were used to measure the defect size and surface area. RESULTS Of the 35 patients with secundum-type ASDs, 5 subjects had disqualifying anatomy by CTA and 2 had an unsuccessful closure, resulting in a procedural success rate of 93%. Measurement of defect area by gated MPR images provided the strongest correlate to ICE balloon size. In large ASDs, TEE was less well correlated to the maximum defect size and identification of the inferior/inferoposterior rims than CTA. CONCLUSIONS Cardiac CTA is an accurate and useful technique for pre-procedural assessment of ASDs and may be superior to conventional TEE in large defects that have deficient inferior rims.
Collapse
Affiliation(s)
- Robert A Quaife
- Advanced Cardiac Imaging, Department of Medicine and Radiology, University of Colorado Health Sciences Center, PO Box 6511 Leprino Building 532, Cardiac and Vascular Center, 12401 E 17th Avenue, Aurora, CO 80045, USA.
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Li GS, Kong GM, Wang YL, Jin YP, Ji QS, Li JF, You BA, Zhang Y. Safety and efficacy of transcatheter closure of atrial septal defects guided by transthoracic echocardiography: a prospective study from two Chinese Medical Centers. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:58-64. [PMID: 18718698 DOI: 10.1016/j.ultrasmedbio.2008.06.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2007] [Revised: 03/13/2008] [Accepted: 06/23/2008] [Indexed: 05/26/2023]
Abstract
The purpose of this study was to evaluate the safety and efficacy of transcatheter atrial septal defect (ASD) closure guided by transthoracic echocardiography (TTE). A total of 191 patients with ASD were recruited from two Chinese medical centers and TTE was carefully performed in multiple views to observe ASD number, position, diameter and relation with adjacent cardiac structures. All patients were divided into three groups based on their largest ASD diameters: 66 subjects with ASD diameter 5-14 mm (group A); 60 subjects with ASD diameter 15-20 mm (group B); and 65 subjects with ASD diameter 21-38 mm (group C). Atrial septal occluders (ASOs) were successfully deployed in 188 patients (98.4%) and ASD was successfully closed at 6-mo follow-up in 185 patients (96.9%). The difference between diameters of ASO and ASD (ASO-ASD) in groups A, B and C were 3.9 +/- 2.4 (0-7) mm, 5.0 +/- 2.6 (3-8) mm and 6.2 +/- 3.8 (5-11) mm, respectively. In group A, no complications occurred. In group B, only four patients had mild complications such as sinus bradycardia, transient hematuria and migraine, all of which disappeared after treatment. In group C, one patient developed ASO migration into the right atrium and two patients had their ASO migrated into the right ventricular outflow tract. Immediately after the closure, 60 (90.9%), 53 (88.3%) and 53 (82.8%) patients had complete ASD closure; 2, 4 and 6 patients had trivial residual shunts; 4, 3 and 2 patients had small residual shunts; and 0, 0 and 2 patients had moderate residual shunts in groups A, B and C, respectively. Most of the residual shunts were persistent at 6-mo follow-up. No embolism or death at procedure and 6-mo follow-up occurred. In conclusion, TTE is a reliable technique for measurement of ASD diameter, guidance of transcatheter ASD closure and evaluation of residual shunts. Transcatheter ASD closure guided by TTE is safe and effective, especially in patients with ASD <or=20 mm.
Collapse
Affiliation(s)
- Gui-Shuang Li
- The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education and Chinese Ministry of Health, Shandong University Qilu Hospital, Jinan, Shandong, China
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Chien JC, Hwang B, Fu YC, Lee PC, Hsieh KS, Jan SL. Sizing of atrial septal defects by intracardiac echocardiography for device closures. J Chin Med Assoc 2008; 71:399-405. [PMID: 18772119 DOI: 10.1016/s1726-4901(08)70090-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Transcatheter closure of a secundum atrial septal defect (ASD) has become an effective method for surgical treatment. In this study, we evaluated the feasibility and accuracy of intracardiac echocardiography (ICE) for sizing ASDs compared with conventional methods. METHODS Between January 2004 and December 2006, 270 patients underwent transcatheter closure of secundum ASD by using septal occluders. For 142 patients, the procedure was guided by transesophageal echocardiography (TEE), and for 128 patients by ICE. We compared the maximal diameters of the ASDs obtained during angiocardiography, transthoracic echocardiography (TTE), ICE, and TEE with balloon-stretched sizes ascertained by using a sizing plate. RESULTS ASD diameters measured with the sizing plate were significantly correlated with those measured with ICE (r = 0.963), TEE (r = 0.912), angiography (r = 0.88), and TTE (r = 0.85). The predicted stretched diameter of the ASDs, i.e. (nonstretched diameter measured with ICE x 1.07) + 3.23 mm, agreed well with that measured by using a sizing plate (Ri = 0.974). CONCLUSION ASD diameters measured with ICE correlated with sizing-plate measurements better than those determined with TEE, angiography or TTE.
Collapse
Affiliation(s)
- Jen-Chung Chien
- Department of Pediatrics, Lo-Tung Pohai Hospital, Ilan, Republic of China
| | | | | | | | | | | |
Collapse
|
11
|
Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects. Chin Med J (Engl) 2008. [DOI: 10.1097/00029330-200806010-00003] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
12
|
Zanchetta M, Pedon L, Olivieri A, Benacchio L. Randomized study comparing mechanical with electronic 2-dimensional intracardiac ultrasound monitoring (MEDIUM) during percutaneous closure of patent foramen ovale in adult patients with cryptogenic stroke. Echocardiography 2008; 25:496-503. [PMID: 18279406 DOI: 10.1111/j.1540-8175.2007.00622.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Previous studies have shown that mechanical and electronic intracardiac echocardiography (ICE) improves ultrasound monitoring during transcatheter patent foramen ovale (PFO) interventional closure. OBJECTIVES This study sought to compare the procedural data, clinical imaging quality, and effectiveness PFO closure by using two different ICE monitoring modalities. METHODS Patients referred for PFO closure (n = 82) were randomly assigned to mechanical (group 1) or electronic (group 2) ICE monitoring of Amplatzer device implantation. The digital ICE images were evaluated offline by means of absolute visual grading analysis score (VGAS(abs)), and the residual shunting at follow-up were assessed by means of contrast echocardiographic studies, all blinded regarding the ICE closure monitoring modality. RESULTS The two groups were comparable with respect to clinical baseline characteristics, intracardiac fossa ovalis measurements, and procedural data (fluoroscopy time, procedure time and measurement of the amount of radiation that the patients absorbed). The total VGAS(abs) ranked the mechanical clinical images in a higher order than the electronic ones (3.78 +/- 0.09 vs 3.58 +/- 0.12, P = 0.005); additionally, three patients (7.3%) of group 2 needed to cross over to mechanical ICE monitoring because a right-convex atrial septal aneurysm configured itself incompletely. No differences in rates of residual shunting were observed at 12 months follow-up between the two groups (97.5% vs 94.7%, P = 0.951). CONCLUSIONS Electronic monitoring of PFO closure performed a less diagnostic impact than the mechanical one while maintaining comparable procedural data and clinical outcome. These results represent an important step in validating these new intracardiac ultrasound imaging modalities.
Collapse
Affiliation(s)
- Mario Zanchetta
- Department of Cardiovascular Disease, Cittadella, Padua, Italy.
| | | | | | | |
Collapse
|
13
|
Assessment of atrial septum morphology by live three-dimensional echocardiography. ACTA ACUST UNITED AC 2008; 27:687-90. [PMID: 18231744 DOI: 10.1007/s11596-007-0618-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2007] [Indexed: 10/19/2022]
Abstract
To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics and dynamic change of the overall anatomic structure of atrial septum. The study examined 49 patients with atrial septal defect (ASD), including 3 patients with atrial septal aneurysm, and 10 healthy subjects. ASD in the 35 patients was surgically confirmed. The maximal diameters of ASD were measured and the percentages of area change were calculated. The parameters derived from L3DE were compared with intraoperative measurements. The results showed that L3DE could directly and clearly display the morphological features of overall anatomic structure of normal atrial septum, repaired and artificially-occluded atrial septum, atrial septal aneurysm. The defect area in ASD patients changed significantly during cardiac cycle, which reached a maximum at end-systole and a minimum at end-diastole, with a mean change percentage of 46.6%, ranging from 14.8% to 73.4%. The sizes obtained from L3DE bore an excellent correlation with intraoperative findings (r=0.90). It is concluded that L3DE can clearly display the overall morphological features and dynamic change of atrial septum and measure the size of ASD area accurately, which is important in the decision to choose therapeutic protocols.
Collapse
|
14
|
Kort S. Intracardiac Echocardiography: Evolution, Recent Advances, and Current Applications. J Am Soc Echocardiogr 2006; 19:1192-201. [PMID: 16950482 DOI: 10.1016/j.echo.2006.04.033] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2006] [Indexed: 11/21/2022]
Affiliation(s)
- Smadar Kort
- Division of Cardiology, State University of New York, Stony Brook, New York 11794-8171, USA.
| |
Collapse
|
15
|
Zanchetta M, Rigatelli G, Pedon L, Zennaro M, Dimopoulous K, Onorato E, Frescura C, Maiolino P, Thiene G, Angelini A. Intracardiac echocardiography: gross anatomy and magnetic resonance correlations and validations. Int J Cardiovasc Imaging 2005; 21:391-401. [PMID: 16047120 DOI: 10.1007/s10554-004-5809-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2004] [Accepted: 10/07/2004] [Indexed: 11/28/2022]
Abstract
PURPOSE The feasibility and safety of intracardiac echocardiography (ICE) in humans, using low frequency transducers, and its excellent tissue contrast capabilities that enhances the differentiation of intracardiac structures have been previously demonstrated. However, correlations among ICE imaging and anatomic sections or magnetic resonance (MR) scan planes have never been described before. This study was designed to correlate a simplified ICE approach with the anatomy of the right atrium and great vessels obtained by serial post-mortem sections and cardiac MR images. METHODS A stepwise approach to ICE, which is based on our experience on over 300 consecutive patients with interatrial communications, has been correlated with anatomic sections from pressure-perfused-fixed hearts and spin echo cardiac MR imaging. A 9F-9 MHz mechanical device was used to record four transverse and one longitudinal sections for an extensive evaluation of the intracardiac architecture. RESULTS ICE transverse and longitudinal views allowed the detection of all the required information. Moreover, the anatomic sections and cardiac MR scan planes allowed validation of all the structures imaged by ICE. The potential clinical applications of the ICE technique are further discussed. CONCLUSION This paper demonstrates the basic accuracy of this new imaging modality. Therefore, mechanical ICE might be considered an active investment in cardiac catheterization laboratories, specifically in the percutaneous interventional procedure setting, discovering a new route (let's see and treat) to sophisticated interventions. In this respect, there can be little doubt that the knowledge of cross-sectional mechanical ICE imaging provides the basis for understanding the heart anatomy.
Collapse
Affiliation(s)
- Mario Zanchetta
- Department Cardiovascular Disease, Cittadella General Hospital, Padova, Cittadella, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Durongpisitkul K, Tang NL, Soongswang J, Laohaprasitiporn D, Nanal A. Predictors of successful transcatheter closure of atrial septal defect by cardiac magnetic resonance imaging. Pediatr Cardiol 2004; 25:124-30. [PMID: 14668961 DOI: 10.1007/s00246-003-0481-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
The location, size, and rim of an atrial septal defect (ASD) are major determining factors for transcatheter closure. We compared the measurements of ASD size and the characteristics of atrial septal rim using cardiac magnetic resonance imaging (MRI) with those obtained using transesophageal echocardiography (TEE). Patients with an ASD that met established criteria were selected for evaluation by cardiac MRI and TEE. There were 66 patients who underwent both TEE and cardiac MRI. Bland-Altman comparative analysis was performed to demonstrate agreement between measurement of ASD by MRI and balloon sizing compared to measurement of ASD by TEE and balloon sizing. Twelve patients were excluded from transcatheter closure of ASD. TEE did not demonstrate an adequate measurement of the posterior inferior rim in 10 of 66 patients. Fifty-four patients underwent transcatheter closure using the Amplatzer septal occluder. Of these, 52 patients had successful closure (ASD measurements of 25.9 +/- 5.6 mm using MRI and 21.9 +/- 5.8 mm using TEE). The median device size was 28 mm (range, 11-38). Patients who had successful closure had a significantly smaller major axis of ASD and larger posterior inferior rim compared to those of patients who were excluded from the closure procedure. Cardiac MRI showed a better correlation of ASD diameter measurement to balloon sizing compared to TEE. We believe that the most important predictive factor for successful transcatheter closure of an ASD is an adequate posterior inferior rim, which is best visualized using cardiac MRI.
Collapse
Affiliation(s)
- K Durongpisitkul
- Division of Pediatric Cardiology, Department of Pediatrics, Faculty of Medicine Siriraj Hospital, Mahidol University, Prannok Road, Bangkok, Thailand 10700.
| | | | | | | | | |
Collapse
|
17
|
Liu Z, McCormick D, Dairywala I, Surabhi S, Goldberg S, Turi Z, Vannan MA. Catheter-based intracardiac echocardiography in the interventional cardiac laboratory. Catheter Cardiovasc Interv 2004; 63:63-71. [PMID: 15343570 DOI: 10.1002/ccd.20106] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Recent advances in technology have engendered a renewed enthusiasm in the use of intracardiac echocardiography (ICE) to guide and assess cardiac interventions. AcuNav is a phased-array sector imaging probe equipped with color and spectral Doppler capabilities. Previous-generation imaging catheters yielded unfamiliar limited-depth radial images with no flow information. Current imaging technology such as the AcuNav has not only consolidated the role of ICE but opened newer applications in the interventional laboratory. ICE has clear advantages over transesophageal echocardiography as the imaging modality of choice in the cardiac catheterization and electrophysiological laboratories. We review the technical evolution of ICE and describe the expanded utility of the AcuNav imaging catheter during cardiac interventions.
Collapse
Affiliation(s)
- Zheng Liu
- Department of Cardiovascular Medicine and Surgery, Drexel University College of Medicine, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | |
Collapse
|
18
|
Rhodes JF, Qureshi AM, Preminger TJ, Tuzcu EM, Casserly IP, Dauterman KW, Prieto LR, Mesia CI, Lane GK, Radvansky PA, Latson LA. Intracardiac echocardiography during transcatheter interventions for congenital heart disease. Am J Cardiol 2003; 92:1482-4. [PMID: 14675594 DOI: 10.1016/j.amjcard.2003.08.067] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Although transesophageal echocardiography is often used for guidance during transcatheter interventions, few data exist regarding the use of the newer modality of intracardiac echocardiography. This brief report summarizes our single center experience using intracardiac echocardiographic guidance during transcatheter interventional procedures for congenital heart disease.
Collapse
Affiliation(s)
- John F Rhodes
- Department of Cardiovascular Medicine, Cleveland, Ohio, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Koenig PR, Abdulla RI, Cao QL, Hijazi ZM. Use of Intracardiac Echocardiography to Guide Catheter Closure of Atrial Communications. Echocardiography 2003; 20:781-7. [PMID: 14641386 DOI: 10.1111/j.0742-2822.2003.03039.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Intracardiac echocardiography (ICE) is slowly replacing transesophageal echocardiography as the preferred imaging tool to guide device closure of atrial septal defects and patent foramen ovale. This article is a brief review of the literature related to ICE, the technical aspects ICE imaging, techniques for obtaining the standard views, and the future directions of this methodology.
Collapse
Affiliation(s)
- Peter R Koenig
- Section of Pediatric Cardiology, Department of Pediatrics, The University of Chicago, Children's Hospital, Chicago, Illinois 60637, USA
| | | | | | | |
Collapse
|
20
|
Zanchetta M, Onorato E, Rigatelli G, Pedon L, Zennaro M, Carrozza A, Maiolino P. Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect. J Am Coll Cardiol 2003; 42:1677-82. [PMID: 14607459 DOI: 10.1016/j.jacc.2003.08.023] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVES We assessed the use of intracardiac echocardiography (ICE) as the primary means for both selection of the Amplatzer Septal Occluder (ASO) and the guidance of transcatheter closure of secundum atrial septal defects (ASDs). BACKGROUND The standard method for transcatheter closure of ASDs requires balloon-sizing maneuver and transesophageal echocardiographic (TEE) monitoring. The role of ICE during transcatheter closure of ASDs has not yet been established. METHODS In 91 patients with ASDs, two standardized orthogonal sections were used to obtain ICE-derived measurements of the fossa ovalis and to assess optimal device deployment: the transverse section on the aortic valve plane, and the longitudinal section on the four-chamber plane. RESULTS In all patients, ICE planes were identified with excellent resolution, providing proper measurements of the fossa ovalis, from which to derive geometric assumptions for the selection of an appropriately sized device. The ASO waist diameter was chosen on the basis of the r value (r = [square root c(2) + p(2)], where r is the radius of an ideal circle that intersects the elliptical fossa ovalis in its semi-latus rectum, c is the foci half-distance of the fossa ovalis, and p is its semi-latus rectum). During the procedure, the four-chamber plane allowed us to obtain easily interpretable images of all stages of device deployment. Midterm complete occlusion rate was 97.8%. No ICE-related complications occurred. CONCLUSIONS The ICE evaluation of ASDs allows quantitative and qualitative information for both proper ASO selection and optimal device placement, thus eliminating the cumbersome balloon-sizing maneuver and the need for general anesthesia during TEE monitoring.
Collapse
Affiliation(s)
- Mario Zanchetta
- Department of Cardiovascular Disease, Cittadella General Hospital, Via Riva Ospedale, Padua, Italy.
| | | | | | | | | | | | | |
Collapse
|
21
|
Rhodes JF, Lane GK, Tuzcu EM, Latson LA. Invasive echocardiography: the use of catheter imaging by the interventional cardiologist. Catheter Cardiovasc Interv 2003; 59:277-90. [PMID: 12772260 DOI: 10.1002/ccd.10453] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Ultrasound imaging is frequently used for diagnostic purposes or guidance during procedures in the pediatric and congenital cardiac catheterization laboratory. As new imaging modalities emerged, many interventional cardiologists rather than noninvasive specialists are now performing the ultrasound imaging as part of the catheterization. The focus of this discussion will be to detail the technique and application of echocardiography by the interventional cardiologist.
Collapse
Affiliation(s)
- John F Rhodes
- The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA.
| | | | | | | |
Collapse
|
22
|
Butera G, Chessa M, Bossone E, Negura DG, De Rosa G, Carminati M. Transcatheter closure of atrial septal defect under combined transesophageal and intracardiac echocardiography. Echocardiography 2003; 20:389-90. [PMID: 12848886 DOI: 10.1046/j.1540-8175.2003.03048.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Gianfranco Butera
- Pediatric Cardiology, Istituto Policlinico San Donato, San Donato Milanese (MI), Italy.
| | | | | | | | | | | |
Collapse
|
23
|
Rigby ML. Transoesophageal echocardiography during interventional cardiac catheterisation in congenital heart disease. Heart 2001; 86 Suppl 2:II23-9. [PMID: 11709531 PMCID: PMC1766548 DOI: 10.1136/heart.86.suppl_2.ii23] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Affiliation(s)
- M L Rigby
- Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK.
| |
Collapse
|