Higashigaito K, Pfirrmann CWA, Koch S, Graf D, Schweizer A, Nanz D, Rosskopf AB. Ligaments of the scapho-trapezial-trapezoidal joint: MR anatomy in asymptomatic and symptomatic individuals.
Skeletal Radiol 2022;
51:637-647. [PMID:
34309690 PMCID:
PMC8763724 DOI:
10.1007/s00256-021-03865-x]
[Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 07/02/2021] [Accepted: 07/04/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE
To evaluate the MRI anatomy of the scapho-trapezial-trapezoidal (STT) ligament complex in asymptomatic and symptomatic individuals.
MATERIAL AND METHODS
In this retrospective study, STT ligament complex of 42 (male 69%, median age 37.5 years) asymptomatic (n = 25) and symptomatic (n = 17) (defined as pain described over the STT joint) individuals was examined using a high-resolution 3D proton density-weighted isovoxel sequence (MR arthrogram) with multiplanar reconstructions. Two musculoskeletal radiologists independently assessed visibility, signal intensity (SI), morphology, and thickness of the radiopalmar scapho-trapezial ligament (rpSTL), palmar scapho-capitate capsular ligament (pSCL), palmar STT capsule (pSTTC), and dorsal STT capsule (dSTTC).
RESULTS
Interreader agreement ranged from fair to good and intraclass correlations were good. The rpSTL was almost always visible (85.7%/80.1%; reader 1/reader 2). The pSCL and dSTTC were visible in all cases. The pSTTC was visible in only 52.4%/42.9%. Mean thickness of the rpSTL, pSCL, pSTTC, and dSTTC was 1.4 ± 0.5 mm/1.3 ± 0.5 mm, 2.8 ± 0.7 mm/2.7 ± 0.6 mm, 0.5 ± 0.5 mm/0.4 ± 0.4 mm, and 0.5 ± 0.3 mm/0.3 ± 0.3 mm. Both readers rated SI of the rpSTL significantly more often as increased in the symptomatic group (increased SI in asymptomatic group: 20%/15%; symptomatic group: 56%/50%) (p-values < 0.005). For all other ligaments, no significant difference was observed for SI between symptomatic and asymptomatic group (p-values ranging between 0.188 and 0.890). For all other ligaments, no significant differences were observed regarding ligament visibility, morphology, and thickness (p-values ranging between 0.274 and 1.000).
CONCLUSION
The anatomy of the STT ligament complex can consistently be visualized on high-resolution 3D MRI. Increased signal intensity of rpSTL is significantly more frequent in patients with radial-sided wrist pain.
Collapse