1
|
Tanaka N, Naka K, Saito A, Morishita J, Toyofuku F, Ohki M, Higashida Y. Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals. Radiol Phys Technol 2012; 6:54-60. [DOI: 10.1007/s12194-012-0169-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2011] [Revised: 07/15/2012] [Accepted: 07/18/2012] [Indexed: 10/28/2022]
|
2
|
Shire NJ, Dardzinski BJ. Picture-perfect: imaging techniques in juvenile idiopathic arthritis. ACTA ACUST UNITED AC 2011. [DOI: 10.2217/iim.11.63] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
3
|
Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques. Int J Cardiol 2010; 156:295-302. [PMID: 21185613 DOI: 10.1016/j.ijcard.2010.11.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2010] [Revised: 10/26/2010] [Accepted: 11/22/2010] [Indexed: 11/23/2022]
Abstract
BACKGROUND Flat-panel computed tomography (FpCT) provides better spatial resolution than 64-channel CT (64-CT) and may improve in vivo quantitative assessment of atherosclerotic plaques. METHODS AND RESULTS Lesions in 184 aortic histology sections from 6 Watanabe heritable hyperlipidemic rabbits were quantitatively compared with 64-CT (image thickness, 0.625 mm) and FpCT (image thickness, 0.150 mm) images. Images were re-oriented perpendicular to the vessel centerline. For detecting plaque, FpCT and 64-CT were not significantly different (sensitivity, 76% vs 66%; P=NS). Although FpCT was significantly more sensitive (42% vs 0%; P=<0.001) for detecting eccentric lesions, the area under the curve (AUC) for FpCT (0.6) was not significantly different from that for 64-CT (0.45; P=NS). In detecting plaques with ≤ 10% lipid (low attenuation foci), FpCT was significantly more sensitive than 64-CT (24% vs 0.7%; P<0.00) and had a significantly greater AUC (0.6 vs 0.5; P<0.006). Additionally, FpCT was more sensitive (65% vs 0%; P<0.00) in detecting plaques with ≤ 5% calcium (high attenuation foci) but not in detecting branch points. Both FpCT and histology allowed us to detect low-attenuation foci as small as 0.3mm in diameter, whereas 64-CT allowed us to detect only low-attenuation foci ≥ 1.5mm in diameter. CONCLUSIONS Flat-panel CT seemed to have more potential for quantitatively screening low-risk small atherosclerotic lesions, whereas 64-CT was apparently more useful when imaging established, well-characterized lesions, particularly when measuring the vascular wall thickness in a rabbit model of atherosclerosis.
Collapse
|
4
|
Synovial and inflammatory diseases in childhood: role of new imaging modalities in the assessment of patients with juvenile idiopathic arthritis. Pediatr Radiol 2010; 40:985-98. [PMID: 20432018 DOI: 10.1007/s00247-010-1612-z] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2010] [Accepted: 02/06/2010] [Indexed: 10/19/2022]
Abstract
Juvenile idiopathic arthritis (JIA) represents a group of heterogeneous diseases characterized by a chronic inflammatory process primarily targeting the synovial membrane. A persistent synovitis is associated with an increased risk of osteocartilaginous damage.With the advent of effective structure-modifying treatment for JIA, it may be possible to significantly reduce or even completely prevent structural damage and associated functional disability. The trend towards early suppression of inflammation, in order to prevent erosive disease, shifts the emphasis away from conventional radiographic detectable structural damage to the slightest traces of early joint damage, and drives the need for alternative imaging techniques more sensitive in detecting early signs of disease activity and damage. In this regard MRI and US are playing an increasing role in the evaluation of arthritic joints.This article will review the key aspects of the current status and recent important advances of imaging techniques available to investigate the child with rheumatic disease, briefly discussing conventional radiography, and particularly focusing on MRI and US. In this era of advancing imaging technology, knowledge of the relative values of available imaging techniques is necessary to optimize the management of children with JIA.
Collapse
|
5
|
Sehmisch S, Dullin C, Zaroban A, Tezval M, Rack T, Schmelz U, Seidlova-Wuttke D, Dunkelberg H, Wuttke W, Marten K, Stuermer KM, Stuermer EK. The use of flat panel volumetric computed tomography (fpVCT) in osteoporosis research. Acad Radiol 2009; 16:394-400. [PMID: 19268850 DOI: 10.1016/j.acra.2008.09.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2008] [Revised: 09/23/2008] [Accepted: 09/24/2008] [Indexed: 11/18/2022]
Abstract
RATIONALE AND OBJECTIVES Improvements in imaging technology have led to the increased use of computed tomography (CT). For example, micro-CT and quantitative CT (QCT) are now often used in osteoporosis research, in which micro-CT is able to analyze small bones or bone samples with high spatial resolution. In contrast, QCT is able to investigate large samples with low spatial resolution. The aim of this study was to test the usefulness of flat-panel volumetric CT (fpVCT) in a rat model of osteopenia. MATERIAL AND METHODS Twenty-two 3-month-old rats underwent ovariectomy and were either left untreated or supplemented with estradiol for 15 weeks. After sacrificing, the rats' second lumbar vertebral body bone mineral density (BMD) was analyzed using fpVCT and ashing. The results were compared to those of a microstructural analysis of the first lumbar vertebrae and a biomechanical evaluation of the fourth lumbar vertebrae. RESULTS BMD measurements using both fpVCT (0.39 vs 0.35 mg/cm(3)) and ashing (0.52 vs 0.48 mg/cm(3)) demonstrated a significant improvement after estradiol supplementation. The correlation coefficient of the two methods was 0.858. After estradiol supplementation, the bone microstructural and bone biomechanical parameters were improved, compared to no treatment. The correlations of both the microstructural and the biomechanical evaluations were closer for BMD measured using fpVCT (r = 0.482-0.769) than on the basis of ashing (r = 0.345-0.573). FpVCT was not able to display the trabecular microstructure of the rat lumbar vertebrae. CONCLUSION The use of fpVCT demonstrated a close relationship between morphologic and biomechanical evaluations in a rat model of osteopenia. Because of its different proportions, fpVCT might be able to bridge the gap between micro-CT and QCT in analyzing larger animals.
Collapse
Affiliation(s)
- Stephan Sehmisch
- University of Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Kleinman PL, Zurakowski D, Strauss KJ, Cleveland RH, Perez-Rosello JM, Nichols DP, Zou KH, Kleinman PK. Detection of Simulated Inflicted Metaphyseal Fractures in a Fetal Pig Model: Image Optimization and Dose Reduction with Computed Radiography. Radiology 2008; 247:381-90. [DOI: 10.1148/radiol.2472070811] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
7
|
Österreichische Expertenmeinung zum Standard der Verlaufsbeurteilung von Patienten mit chronischer Polyarthritis (rheumatoider Arthritis). Wien Klin Wochenschr 2008; 120:234-41. [DOI: 10.1007/s00508-008-0958-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
8
|
Körner M, Weber CH, Wirth S, Pfeifer KJ, Reiser MF, Treitl M. Advances in Digital Radiography: Physical Principles and System Overview. Radiographics 2007; 27:675-86. [PMID: 17495286 DOI: 10.1148/rg.273065075] [Citation(s) in RCA: 96] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
During the past two decades, digital radiography has supplanted screen-film radiography in many radiology departments. Today, manufacturers provide a variety of digital imaging solutions based on various detector and readout technologies. Digital detectors allow implementation of a fully digital picture archiving and communication system, in which images are stored digitally and are available anytime. Image distribution in hospitals can now be achieved electronically by means of web-based technology with no risk of losing images. Other advantages of digital radiography include higher patient throughput, increased dose efficiency, and the greater dynamic range of digital detectors with possible reduction of radiation exposure to the patient. The future of radiography will be digital, and it behooves radiologists to be familiar with the technical principles, image quality criteria, and radiation exposure issues associated with the various digital radiography systems that are currently available.
Collapse
Affiliation(s)
- Markus Körner
- Department of Clinical Radiology, University Hospital Munich, Nussbaumstr 20, 80336 Munich, Germany.
| | | | | | | | | | | |
Collapse
|
9
|
Metz S, Kuhn V, Kettler M, Hudelmaier M, Bonel HM, Waldt S, Hollweck R, Renger B, Rummeny EJ, Link TM. Comparison of Different Radiography Systems in an Experimental Study for Detection of Forearm Fractures and Evaluation of the M??ller-AO and Frykman Classification for Distal Radius Fractures. Invest Radiol 2006; 41:681-90. [PMID: 16896303 DOI: 10.1097/01.rli.0000233326.94998.b0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation. MATERIALS AND METHODS A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis. RESULTS The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications. CONCLUSIONS The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.
Collapse
Affiliation(s)
- Stephan Metz
- Department of Diagnostic Radiology, Technical University of Munich, Ismaninger Strasse 22, 81675 Munich, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Spahn M. Flat detectors and their clinical applications. Eur Radiol 2005; 15:1934-47. [PMID: 15806363 DOI: 10.1007/s00330-005-2734-9] [Citation(s) in RCA: 85] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2004] [Revised: 02/08/2005] [Accepted: 03/01/2005] [Indexed: 11/29/2022]
Abstract
Diagnostic and interventional flat detector X-ray systems are penetrating the market in all application segments. First introduced in radiography and mammography, they have conquered cardiac and general angiography and are getting increasing attention in fluoroscopy. Two flat detector technologies prevail. The dominating method is based on an indirect X-ray conversion process, using cesium iodide scintillators. It offers considerable advantages in radiography, angiography and fluoroscopy. The other method employs a direct converter such as selenium which is particularly suitable for mammography. Both flat detector technologies are based on amorphous silicon active pixel matrices. Flat detectors facilitate the clinical workflow in radiographic rooms, foster improved image quality and provide the potential to reduce dose. This added value is based on their large dynamic range, their high sensitivity to X-rays and the instant availability of the image. Advanced image processing is instrumental in these improvements and expand the range of conventional diagnostic methods. In angiography and fluoroscopy the transition from image intensifiers to flat detectors is facilitated by ample advantages they offer, such as distortion-free images, excellent coarse contrast, large dynamic range and high X-ray sensitivity. These characteristics and their compatibility with strong magnetic fields are the basis for improved diagnostic methods and innovative interventional applications.
Collapse
Affiliation(s)
- Martin Spahn
- Siemens AG, Medical Solutions, Angiography, Fluoroscopic and Radiography Systems, Siemensstrasse 1, 91301 Forchheim, Germany.
| |
Collapse
|
11
|
Neofotistou V, Tsapaki V, Kottou S, Schreiner-Karoussou A, Vano E. Does digital imaging decrease patient dose? A pilot study and review of the literature. RADIATION PROTECTION DOSIMETRY 2005; 117:204-10. [PMID: 16464833 DOI: 10.1093/rpd/nci718] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The potential for decreasing patient dose is one of the main arguments for the justification of the cost of digital imaging equipment. However, the literature review with respect to patient doses using digital imaging modalities, presents conflicting results. During this study, patients' entrance surface doses were measured for three simple radiographic examinations, in European centres equipped with a computed radiography digital system. Results showed that doses between centres varied from 30% for chest LAT to 250% for chest PA examination. With the digital image quality criteria still under discussion, and with the post-processing parameters and/or image documentations varying, any dose comparisons between conventional/digital systems, as well as dose comparisons between different centre using digital units, are difficult. Clinical trials are required in order to define reference levels associated with quality of digital image necessary to address specific clinical requirements.
Collapse
Affiliation(s)
- V Neofotistou
- Medical Physics Department, Athens General Hospital, 11527 Athens, Greece.
| | | | | | | | | |
Collapse
|
12
|
Nikolaou K, Flohr T, Stierstorfer K, Becker CR, Reiser MF. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience. Eur Radiol 2004; 15:329-33. [PMID: 15662479 DOI: 10.1007/s00330-004-2537-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2004] [Revised: 09/08/2004] [Accepted: 10/06/2004] [Indexed: 10/26/2022]
Abstract
The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024x768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25x0.25x0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed.
Collapse
Affiliation(s)
- Konstantin Nikolaou
- Department of Clinical Radiology, Ludwig-Maximilians-University, Munich, Germany.
| | | | | | | | | |
Collapse
|
13
|
Völk M, Hamer OW, Feuerbach S, Strotzer M. Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature. Eur Radiol 2004; 14:827-34. [PMID: 14968260 DOI: 10.1007/s00330-004-2243-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2003] [Accepted: 01/05/2004] [Indexed: 11/29/2022]
Abstract
The two most frequently performed diagnostic X-ray examinations are those of the extremities and of the chest. Thus, dose reduction in the field of conventional skeletal and chest radiography is an important issue and there is a need to reduce man-made ionizing radiation. The large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide provides a significant reduction of radiation dose in skeletal and chest radiography compared with traditional imaging systems. This article describes the technical background and basic image quality parameters of this 43 x 43-cm digital system, and summarizes the available literature (years 2000-2003) concerning dose reduction in experimental and clinical studies. Due to its high detective quantum efficiency and dynamic range compared with traditional screen-film systems, a dose reduction of up to 50% is possible without loss of image quality.
Collapse
Affiliation(s)
- Markus Völk
- Department of Diagnostic Radiology, University Hospital of Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.
| | | | | | | |
Collapse
|