1
|
Zhao X, Zeng D, He L, Sun W. Clinical and imaging characteristics of cardiac magnetic resonance presenting with myocardial infarction with non-obstructive coronary arteries in China. J Cardiothorac Surg 2022; 17:332. [PMID: 36550481 PMCID: PMC9783435 DOI: 10.1186/s13019-022-02072-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 12/09/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND The characteristics are still unclear due to lack of systematic research on patients with myocardial infarction non-obstructive coronary arteries (MINOCA) in China. This study aimed to explore the clinical and imaging features of MINOCA patients. METHODS The patients who were diagnosed as suspected MI were studied. Cardiac magnetic resonance (CMR) was performed after coronary angiography or coronary computed tomographic angiography examination within one week. Myocardial infarction (MI) was determined by late gadolinium enhancement CMR.The patients with MI were divided into MINOCA and MICAD group according to whether the degree of coronary stenosis was greater than 50%. Cardiac function and imaging characteristics between the two groups were analyzed. RESULTS 21 patients with MINOCA and 30 patients with myocardial infarction with obstructive coronary artery disease (MICAD) were analyzed. MINOCA patients were younger, and the electrocardiogram was commonly featured by non-ST-elevation. The parameters of left ventricular function were significantly different between the two groups including left ventricular ejection fraction, stroke volume, cardiac output, myocardial mass, and peak ejection rate (P < 0.05). Besides, MINOCA patients had smaller area of MI, less score of transmural extent, fewer involved segments. Furthermore, the transmural extent of MI in MINOCA patients was mainly grade I, that is, most of them were subendocardial MI, which was significantly negatively correlated with the amount of first-pass perfusion. CONCLUSIONS The clinical characteristics combined with imaging features of CMR may be effective to evaluate the cardiac function in order to make clinical decision for MINOCA patients in China.
Collapse
Affiliation(s)
- Xinxiang Zhao
- grid.415444.40000 0004 1800 0367Department of Radiology, The Second Affiliated Hospital of Kunming Medical University, No. 374, Dian-mian Avenue, Wuhua District, Kunming, 650101 China
| | - Daobing Zeng
- grid.443573.20000 0004 1799 2448Department of PET Center, Taihe Hospital, Hubei University of Medicine, Shiyan, China
| | - Liping He
- grid.285847.40000 0000 9588 0960Department of Epidemiology and Biostatistics, School of Public Health, Kunming Medical University, Kunming, China
| | - Wenjing Sun
- grid.414011.10000 0004 1808 090XDepartment of Cardiology, Henan Provincial People’s Hospital, No. 7, Weiwu Road, Jinshui District, Zhengzhou, China
| |
Collapse
|
2
|
Computed tomography of coronary artery atherosclerosis: A review. J Med Imaging Radiat Sci 2021; 52:S19-S39. [PMID: 34479831 DOI: 10.1016/j.jmir.2021.08.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/29/2021] [Accepted: 08/06/2021] [Indexed: 11/23/2022]
Abstract
Coronary artery atherosclerosis resulting in ischemic cardiac disease is the leading cause of mortality in the United States. In symptomatic patients, invasive diagnostic methods like catheter angiography, intravascular ultrasound, or vascular endoscopy may be used. However, for primary prevention of atherosclerotic coronary artery disease in asymptomatic patients, non-invasive methods are more commonly utilized like stress imaging, single-photon emission computed tomography (SPECT) and coronary artery calcification scoring. Coronary computed tomographic angiography (CCTA) is an excellent diagnostic tool for detection of coronary artery plaque and ability to identify resultant stenoses with an excellent negative predictive value which can potentially result in optimal exclusion of the presence of coronary artery disease. Long term follow up after a negative CCTA has repeatedly demonstrated very low incidence of future adverse coronary events, attesting its predictive value. CCTA based management is associated with improved CAD outcome in stable angina. Coronary CTA is valuable in acute chest pain evaluation in the emergency department helping in better triage. CT perfusion and CT-FFR are both very promising tools for assessment of hemodynamic significance of coronary artery stenosis.
Collapse
|
3
|
Elagha A, Othman Y, Darweesh R, Awadein G, Hashad A. Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography. Egypt Heart J 2020; 72:81. [PMID: 33180202 PMCID: PMC7661592 DOI: 10.1186/s43044-020-00109-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 10/14/2020] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Assessment of the interatrial septum (IAS) has become an attractive area of interest for a variety of important interventional procedures. Newer imaging modalities like multi-slice computed tomography (MSCT) and cardiac MRI (CMR) can provide higher resolution and wider field of view than echocardiography. Moreover, high-field (3-Tesla) CMR can even enhance spatial and temporal resolution.
The characteristics of the interatrial septum were retrospectively studied in 371 consecutive subjects (201 men, 31–73 years old) in whom MSCT was performed primarily for non-invasive evaluation of the coronary arteries. All subjects underwent both MSCT and MRI scans within 0–30 day’s interval. A 3D volume covering the whole heart was acquired across the heart with and without contrast enhancement. Also, patients underwent cardiac MSCT examinations using 64-row MSCT scanners.
Results
The mean scan time of MSCT was 10.4 ± 2.8 s and 9.7 ± 2.9 min for CMR. The mean length of IAS by CMR and CT was 39.65 ± 4.6 mm and 39.28 ± 4.7 mm, respectively. The mean maximal thickness of IAS by CMR and CT was 3.1 ± 0.97 mm and 3.15 ± 0.95 mm, respectively. The mean thickness of fossa ovalis by CMR and CT was 1.04 ± 0.36 mm and 1.04 ± 0.44 mm, respectively. The mean length of fossa ovalis by CMR and CT was 12.8 ± 3.7 mm and 12.8 ± 3.5 mm, respectively. Finally, the mean angle of IAS by CMR and CT was identical (155 ± 9.2°). Measurements of various morphological features of IAS showed no statistically significant difference between CMR and CT, with an excellent correlation and close relationship regarding IAS length, maximal IAS thickness, fossa ovalis thickness, fossa ovalis length, and IAS angle (r = 0.98, 0.98, 0.95, 0.96, and 0.92, respectively).
Conclusion
Whole-heart 3D acquisition at 3-T MRI using a free-breathing technique provides a valuable non-invasive imaging tool for excellent assessment of the interatrial septum—as compared to MSCT—that may have significant clinical implication for diagnostic purposes and therapeutic interventional procedures, as it may facilitate planning, improve outcome, and shorten its duration.
Collapse
|
4
|
Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population. J Echocardiogr 2016; 15:18-26. [PMID: 27589871 DOI: 10.1007/s12574-016-0315-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 08/04/2016] [Accepted: 08/14/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Accurate quantification of left ventricular (LV) volumes [end-diastolic volume (EDV) and end-systolic volume (ESV)] and ejection fraction (EF) is of critical importance. The development of real-time three-dimensional echocardiography (RT3DE) has shown better correlation than two-dimensional (2D) echocardiography with magnetic resonance imaging (MRI) measurements. The aim of our study was to assess the accuracy of RT3DE and 64-slice computed tomography (CT) in the evaluation of LV volumes and function using MRI as the reference standard in a real-world population with various types of heart disease with different chamber geometry. METHODS The study population consisted of 66 patients referred for cardiac MRI for various pathologies. All patients underwent cardiac MRI, and RT3DE and 64 slices CT were then performed on a subsequent day. The study population was then divided into 5 clinical groups depending on the underlying heart disease. RESULTS RT3DE volumes correlated well with MRI values (R 2 values: 0.90 for EDV and 0.94 for ESV). RT3DE measurements of EF correlated well with MRI values (R 2 = 0.86). RT3DE measurements resulted in slightly underestimated values of both EDV and ESV, as reflected by biases of -9.18 and -4.50 mL, respectively. Comparison of RT3DE and MRI in various types of cardiomyopathies showed no statistical difference between different LV geometrical patterns. CONCLUSION These results confirm that RT3DE has good accuracy in everyday clinical practice and can be of clinical utility in all types of cardiomyopathy independently of LV geometric pattern, LV diameter or wall thickness, taking into account a slight underestimation of LV volumes and EF compared to MRI.
Collapse
|
5
|
Kaniewska M, Schuetz GM, Willun S, Schlattmann P, Dewey M. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis. Eur Radiol 2016; 27:1640-1659. [DOI: 10.1007/s00330-016-4513-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 05/02/2016] [Accepted: 07/18/2016] [Indexed: 01/06/2023]
|
6
|
Melero-Ferrer JL, López-Vilella R, Morillas-Climent H, Sanz-Sánchez J, Sánchez-Lázaro IJ, Almenar-Bonet L, Martínez-Dolz L. Novel Imaging Techniques for Heart Failure. Card Fail Rev 2016; 2:27-34. [PMID: 28875038 DOI: 10.15420/cfr.2015:29:2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Imaging techniques play a main role in heart failure (HF) diagnosis, assessment of aetiology and treatment guidance. Echocardiography is the method of choice for its availability, cost and it provides most of the information required for the management and follow up of HF patients. Other non-invasive cardiac imaging modalities, such as cardiovascular magnetic resonance (CMR), nuclear imaging-positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and computed tomography (CT) could provide additional aetiological, prognostic and therapeutic information, especially in selected populations. This article reviews current indications and possible future applications of imaging modalities to improve the management of HF patients.
Collapse
Affiliation(s)
- Josep L Melero-Ferrer
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| | - Raquel López-Vilella
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| | - Herminio Morillas-Climent
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| | - Jorge Sanz-Sánchez
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| | - Ignacio J Sánchez-Lázaro
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| | - Luis Almenar-Bonet
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| | - Luis Martínez-Dolz
- Advanced Heart Failure and Heart Transplantation Unit, Cardiology Department, Hospital Universitari i Politècnic La Fe,Valencia, Spain
| |
Collapse
|
7
|
Rheinheimer S, Reh C, Figiel J, Mahnken AH. Assessment of right atrium volume by conventional CT or MR techniques: Which modality resembles in vivo reality? Eur J Radiol 2016; 85:1040-4. [PMID: 27130069 DOI: 10.1016/j.ejrad.2016.03.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Revised: 01/24/2016] [Accepted: 03/02/2016] [Indexed: 12/29/2022]
Abstract
PURPOSE Right atrial volume (RAV) is a prognostic factor of the right heart function. This retrospective study evaluates the comparability of computed tomography (CT) and magnetic resonance imaging (MRI) for right atrial volumetry with conventional planimetric and diametric methods. MATERIAL AND METHODS 29 retrospectively included patients (18 male, 47±12years) underwent CT and 1.5 Tesla MRI within 17±20days. RAV was measured using biplane and ellipsoid method (MRI and CT) and Simpson's method (CT). For interobserver comparison measurements were carried out by two observers. Pearson's correlation, Lin's concordance coefficient, and Bland-Altman statistics were calculated. RESULTS There is a correlation of RAV between CT and MRI, r [ellipsoid]=0.65; r [biplane]=0.64 (p<0.001). MRI volumes were significantly lower than CT volumes, [mean±SD] 43±19ml versus 27±9ml, (p<0.002). There was a close interobserver correlation (CT: r=0.83, MRI: r=0.73; p<0.001) but a relatively wide range in Bland-Altman analysis; limits of agreement from ±13ml up to ±29ml. CONCLUSIONS Compared to left atrial volumes, a higher variability was found for RAV values both in interobserver statistiscs and in intermodality comparison. Complex shape of the right atrium, artifacts due to contrast material (CT), high venous return in inspiration (CT), high flow contrast media administration (CT) and increased heart rate (MRI) might cause these clinically relevant variations.
Collapse
Affiliation(s)
- Stephan Rheinheimer
- Philipps University of Marburg, Diagnostic and Interventional Radiology, Baldingerstraße, 35043 Marburg, Germany.
| | - Christina Reh
- Philipps University of Marburg, Diagnostic and Interventional Radiology, Baldingerstraße, 35043 Marburg, Germany
| | - Jens Figiel
- Philipps University of Marburg, Diagnostic and Interventional Radiology, Baldingerstraße, 35043 Marburg, Germany
| | - Andreas H Mahnken
- Philipps University of Marburg, Diagnostic and Interventional Radiology, Baldingerstraße, 35043 Marburg, Germany
| |
Collapse
|
8
|
Singh RM, Singh BM, Mehta JL. Role of cardiac CTA in estimating left ventricular volumes and ejection fraction. World J Radiol 2014; 6:669-676. [PMID: 25276310 PMCID: PMC4176784 DOI: 10.4329/wjr.v6.i9.669] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2014] [Revised: 03/30/2014] [Accepted: 07/17/2014] [Indexed: 02/06/2023] Open
Abstract
Left ventricular ejection fraction (LVEF) is an important predictor of cardiac outcome and helps in making important diagnostic and therapeutic decisions such as the treatment of different types of congestive heart failure or implantation of devices like cardiac resynchronization therapy-defibrillator. LVEF can be measured by various techniques such as transthoracic echocardiography, contrast ventriculography, radionuclide techniques, cardiac magnetic resonance imaging and cardiac computed tomographic angiography (CTA). The development of cardiac CTA using multi-detector row CT (MDCT) has seen a very rapid improvement in the technology for identifying coronary artery stenosis and coronary artery disease in the last decade. During the acquisition, processing and analysis of data to study coronary anatomy, MDCT provides a unique opportunity to measure left ventricular volumes and LVEF simultaneously with the same data set without the need for additional contrast or radiation exposure. The development of semi-automated and automated software to measure LVEF has now added uniformity, efficiency and reproducibility of practical value in clinical practice rather than just being a research tool. This article will address the feasibility, the accuracy and the limitations of MDCT in measuring LVEF.
Collapse
|
9
|
Lo CKL, Mertz D, Loeb M. Newcastle-Ottawa Scale: comparing reviewers' to authors' assessments. BMC Med Res Methodol 2014; 14:45. [PMID: 24690082 PMCID: PMC4021422 DOI: 10.1186/1471-2288-14-45] [Citation(s) in RCA: 1296] [Impact Index Per Article: 129.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2013] [Accepted: 03/17/2014] [Indexed: 02/07/2023] Open
Abstract
Background Lack of appropriate reporting of methodological details has previously been shown to distort risk of bias assessments in randomized controlled trials. The same might be true for observational studies. The goal of this study was to compare the Newcastle-Ottawa Scale (NOS) assessment for risk of bias between reviewers and authors of cohort studies included in a published systematic review on risk factors for severe outcomes in patients infected with influenza. Methods Cohort studies included in the systematic review and published between 2008–2011 were included. The corresponding or first authors completed a survey covering all NOS items. Results were compared with the NOS assessment applied by reviewers of the systematic review. Inter-rater reliability was calculated using kappa (K) statistics. Results Authors of 65/182 (36%) studies completed the survey. The overall NOS score was significantly higher (p < 0.001) in the reviewers’ assessment (median = 6; interquartile range [IQR] 6–6) compared with those by authors (median = 5, IQR 4–6). Inter-rater reliability by item ranged from slight (K = 0.15, 95% confidence interval [CI] = −0.19, 0.48) to poor (K = −0.06, 95% CI = −0.22, 0.10). Reliability for the overall score was poor (K = −0.004, 95% CI = −0.11, 0.11). Conclusions Differences in assessment and low agreement between reviewers and authors suggest the need to contact authors for information not published in studies when applying the NOS in systematic reviews.
Collapse
Affiliation(s)
| | | | - Mark Loeb
- Department of Clinical Epidemiology and Biostatistics, McMaster University, Hamilton Ontario, Canada.
| |
Collapse
|
10
|
Sharma A, Einstein AJ, Vallakati A, Arbab-Zadeh A, Mukherjee D, Lichstein E. Meta-analysis of global left ventricular function comparing multidetector computed tomography with cardiac magnetic resonance imaging. Am J Cardiol 2014; 113:731-8. [PMID: 24355312 DOI: 10.1016/j.amjcard.2013.11.016] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Revised: 11/06/2013] [Accepted: 11/06/2013] [Indexed: 11/17/2022]
Abstract
We compare the diagnostic accuracy of multidetector row computed tomography (MDCT) to cardiac magnetic resonance imaging (CMR) for evaluating global left ventricular function. We systematically searched PubMed, CINAHL, Cochrane CENTRAL, Scopus, and the Web of Science databases for studies published between 1966 to January 2013 that compared left ventricle (LV) volumes, ejection fraction (EF) and LV mass measured by MDCT and CMR. We performed meta-analyses and used random-effects model with inverse variance weighting test to determine the overall bias and limits of agreement of LV end-diastolic volume, end-systolic volume, stroke volume, and EF measured by MDCT and CMR. Furthermore, subgroup analyses were performed to compare 16-slice and 64-slice MDCT with CMR. Two study authors independently reviewed the 90 articles originally identified and selected 27 studies (n = 831) for analysis. Excellent correlation and a linear relation were seen between MDCT and CMR for LV end-diastolic volume (r = 0.93; p <0.001), LV end-systolic volume (r = 0.95; p <0.001), LV stroke volume (r = 0.85; p <0.001), LV ejection fraction (r = 0.93; p <0.001), and LV mass (r = 0.86; p <0.001). Subgroup analyses showed strong positive correlations for both 16- and 64-slice MDCT. In conclusion, although not the first-line test for LV function assessment in most patients, when appropriate, retrospectively gated MDCT provides an accurate and valid assessment of LV function compared with CMR.
Collapse
Affiliation(s)
- Abhishek Sharma
- Department of Medicine, Maimonides Medical Center, Brooklyn, New York.
| | - Andrew J Einstein
- Division of Cardiology, Columbia University Medical Center, New York, New York
| | - Ajay Vallakati
- Division of Cardiology, University of Kansas Medical Center, Kansas City, Kansas
| | - Armin Arbab-Zadeh
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | | | - Edgar Lichstein
- Department of Medicine, Maimonides Medical Center, Brooklyn, New York
| |
Collapse
|
11
|
Weininger M, Renker M, Rowe GW, Abro JA, Costello P, Schoepf UJ. Integrative computed tomographic imaging of coronary artery disease. Expert Rev Cardiovasc Ther 2014; 9:27-43. [DOI: 10.1586/erc.10.166] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
12
|
Pundziute G, Schuijf JD, Jukema JW, de Roos A, van der Wall EE, Bax JJ. Advances in the noninvasive evaluation of coronary artery disease with multislice computed tomography. Expert Rev Med Devices 2014; 3:441-51. [PMID: 16866641 DOI: 10.1586/17434440.3.4.441] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Current noninvasive detection of coronary artery disease (CAD) is based on the demonstration of ischemia using stress-rest imaging, which is an indirect way of identifying CAD by demonstration of the hemodynamic consequences, rather than direct visualization of the obstructive lesions in the coronary arteries. Multislice computed tomography (MSCT) has recently emerged as an extremely rapidly developing noninvasive imaging modality, which allows anatomical imaging of the coronary arteries or noninvasive coronary angiography. In addition, total plaque burden, plaque morphology and (to some extent) plaque constitution can be assessed by MSCT. The technique also provides information on resting left ventricular systolic function, and possibly resting perfusion. Ideally, stress function and perfusion should also be evaluated, since this would allow detection of ischemia and would complete the picture of CAD. However, this is not routinely performed, since sequential acquisitions are associated with high radiation doses and thus pose a limitation for cardiovascular applications of MSCT. It is anticipated that, with a reduction in radiation, MSCT may become an important player in the diagnostic and prognostic work-up of patients with known or suspected CAD.
Collapse
Affiliation(s)
- Gabija Pundziute
- Leiden University Medical Center, Department of Cardiology, Leiden, The Netherlands
| | | | | | | | | | | |
Collapse
|
13
|
Srichai MB, Chandarana H, Donnino R, Lim IIP, Leidecker C, Babb J, Jacobs JE. Diagnostic accuracy of cardiac computed tomography angiography for myocardial infarction. World J Radiol 2013; 5:295-303. [PMID: 24003355 PMCID: PMC3758497 DOI: 10.4329/wjr.v5.i8.295] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2013] [Revised: 06/13/2013] [Accepted: 07/18/2013] [Indexed: 02/06/2023] Open
Abstract
AIM: To investigate diagnostic accuracy of high, low and mixed voltage dual energy computed tomography (DECT) for detection of prior myocardial infarction (MI).
METHODS: Twenty-four consecutive patients (88% male, mean age 65 ± 11 years old) with clinically documented prior MI (> 6 mo) were prospectively recruited to undergo late phase DECT for characterization of their MI. Computed tomography (CT) examinations were performed using a dual source CT system (64-slice Definition or 128-slice Definition FLASH, Siemens Healthcare) with initial first pass and 10 min late phase image acquisitions. Using the 17-segment model, regional systolic function was analyzed using first pass CT as normal or abnormal (hypokinetic, akinetic, dyskinetic). Regions with abnormal systolic function were identified as infarct segments. Late phase DE scans were reconstructed into: 140 kVp, 100 kVp, mixed (120 kVp) images and iodine-only datasets. Using the same 17-segment model, each dataset was evaluated for possible (grade 2) or definite (grade 3) late phase myocardial enhancement abnormalities. Logistic regression for correlated data was used to compare reconstructions in terms of the accuracy for detecting infarct segments using late myocardial hyperenhancement scores.
RESULTS: All patients reported prior history of documented myocardial infarction, with most occurring more than 5 years prior (n = 18; 75% of cohort). Fifty-five of 408 (13%) segments demonstrated abnormal wall motion and were classified as infarct. The remaining 353 segments were classified as non-infarcted segments. A total of 1692 segments were analyzed for late phase enhancement abnormalities, with 91 (5.5%) segments not interpretable due to artifact. Combined grades 2 and 3 compared to grade 3 only enhancement abnormalities demonstrated significantly higher sensitivity and similar specificity for detection of infarct segments for all reconstructions evaluated. Evaluation of different voltage acquisitions demonstrated the highest diagnostic performance for the 100 kVp reconstruction which had higher diagnostic accuracy (87%; 95%CI: 80%-90%), sensitivity (86%-93%; 95%CI: 54%-78%) and specificity (90%; 95%CI: 86%-93%) compared to the other reconstructions. For sensitivity, there were significant differences noted between 100 kVp vs 140 kVp (P < 0.0005), 100 kVp vs mixed (P < 0.0001), and 100 kVp vs iodine only (P < 0.005) using combined grade 2 and grade 3 perfusion abnormalities. For specificity, there were significant differences noted between 100 kVp vs 140 kVp (P < 0.005), and 100 kVp vs mixed (P < 0.01) using combined grades 2 and 3 perfusion abnormalities.
CONCLUSION: Low voltage acquisition CT, 100 kVp in this study, demonstrates superior diagnostic performance when compared to higher and mixed voltage acquisitions for detection of prior MI.
Collapse
|
14
|
Lee M, Park N, Lee S, Lee A, Jung J, Kim Y, Ko S, Kim H, Jeong S, Eom K. Comparison of echocardiography with dual-source computed tomography for assessment of left ventricular volume in healthy Beagles. Am J Vet Res 2013; 74:62-9. [DOI: 10.2460/ajvr.74.1.62] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
15
|
Arraiza M, Azcárate P, Arias J, de Cecco C, Pueyo J, Rábago G, Bastarrika G. Accuracy of different reconstruction intervals to quantify left ventricular function and mass in cardiac computed tomography examinations. RADIOLOGIA 2012. [DOI: 10.1016/j.rxeng.2011.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
16
|
Fuchs A, Kühl JT, Lønborg J, Engstrøm T, Vejlstrup N, Køber L, Kofoed KF. Automated assessment of heart chamber volumes and function in patients with previous myocardial infarction using multidetector computed tomography. J Cardiovasc Comput Tomogr 2012; 6:325-34. [DOI: 10.1016/j.jcct.2012.01.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2011] [Revised: 12/11/2011] [Accepted: 01/22/2012] [Indexed: 10/27/2022]
|
17
|
Sharma A, Arbab-Zadeh A. Assessment of coronary heart disease by CT angiography: current and evolving applications. J Nucl Cardiol 2012; 19:796-806. [PMID: 22527798 DOI: 10.1007/s12350-012-9556-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Computed tomography angiography (CTA) of the heart is a rapidly evolving application for comprehensive assessment of coronary arterial anatomy, myocardial function, perfusion, and myocardial viability. Thus, cardiac CTA is capable of retrieving the most critical information for guiding the management of patients with suspected coronary heart disease (CHD). Ongoing technologic advancements have allowed acquiring such information within minutes, at radiation doses that are lower than those from conventional computed tomography imaging or common nuclear imaging techniques. Cardiac CTA has positioned itself as an imaging modality that may be well suited to fulfill central needs of cardiovascular medicine. This article reviews the evidence for the clinical utility of cardiac CTA in patients with suspected CHD.
Collapse
Affiliation(s)
- Abhishek Sharma
- Department of Medicine, Maimonides Medical Center, Brooklyn, NY, USA
| | | |
Collapse
|
18
|
Arraiza M, Azcárate PM, Arias J, de Cecco CN, Pueyo JC, Rábago G, Bastarrika G. Accuracy of different reconstruction intervals to quantify left ventricular function and mass in cardiac computed tomography examinations. RADIOLOGIA 2011; 54:432-41. [PMID: 21920566 DOI: 10.1016/j.rx.2011.05.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2011] [Revised: 04/15/2011] [Accepted: 05/01/2011] [Indexed: 10/17/2022]
Abstract
PURPOSE To compare the accuracy of cardiac dual-source CT (DSCT) reconstructions obtained at 5% and 10% of the cardiac cycle and MRI for quantifying global left ventricular (LV) function and mass in heart transplant recipients. MATERIAL AND METHODS We prospectively included 23 heart transplant recipients (21 male, mean age 60±11.7 years) who underwent cardiac DSCT and MRI examinations. We compared LV parameters on cardiac DSCT reconstructions obtained at 5% (0%-95%) and 10% (0%-90%) intervals of the cardiac cycle and on double-oblique short-axis MR images. We determined ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and myocardial mass using commercially available semiautomated segmentation analysis software for DSCT datasets and conventional manual contour tracing for MR studies. RESULTS Using different reconstruction intervals to quantify LV parameters at DSCT resulted in non-significant differences (P>.05). Compared to MRI, DSCT slightly overestimated LV-EDV, ESV, and mass when both 5% (11.5±25.1ml, 6.8±10.9ml, and 28.3±21.6g, respectively) and 10% (mean difference 15.3±26.3ml, 7.4±11.5ml, and 29.3±18.7g, respectively) reconstruction intervals were used. DSCT and MRI estimates of EF and SV were not significantly different. CONCLUSION In heart transplant recipients, DSCT allows reliable quantification of LV function and mass compared with MRI, even using 10% interval reconstructions.
Collapse
Affiliation(s)
- M Arraiza
- Servicio de Radiología, Clínica Universidad de Navarra, Pamplona, Navarra, España
| | | | | | | | | | | | | |
Collapse
|
19
|
Schwarz F, Takx R, Schoepf UJ, Lee YS, Ruzsics B, Gassner EM, Chiaramida S, Henzler T. Reproducibility of left and right ventricular mass measurements with cardiac CT. J Cardiovasc Comput Tomogr 2011; 5:317-24. [DOI: 10.1016/j.jcct.2011.08.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2011] [Revised: 07/20/2011] [Accepted: 08/03/2011] [Indexed: 10/17/2022]
|
20
|
Abstract
Over recent decades, noninvasive imaging has become well established in the diagnostic work-up of patients suffering from myocardial infarction. It provides insights into the individual patient's prognosis and guides therapeutic decisions. MRI has long been considered the standard of reference in the noninvasive imaging of myocardial infarction. Only recently have different multidetector-row spiral computed tomography (MDCT) techniques successfully been evaluated for the visualization of myocardial infarction. This article describes different concepts of cardiac MDCT imaging in acute and chronic myocardial infarction. MDCT assessment of myocardial edema, myocardial perfusion and delayed myocardial contrast enhancement are introduced, with the latter evolving as key concept of viability imaging by means of MDCT. The current status of MDCT in the diagnostic work-up of myocardial infarction is reviewed.
Collapse
Affiliation(s)
- Andreas H Mahnken
- Department of Diagnostic and Interventional Radiology, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, D-52074 Aachen, Germany.
| |
Collapse
|
21
|
Abstract
Recent advances in multidetector-row computed tomography (MDCT) technology have created new opportunities in cardiac imaging and provided new insights into a variety of disease states. Use of 64-slice coronary computed tomography angiography has been validated for the evaluation of clinically relevant coronary artery stenosis with high negative predictive values for ruling out significant obstructive disease. This technology has also advanced the care of patients with acute chest pain by simultaneous assessment of acute coronary syndrome, pulmonary embolism, and acute aortic syndrome ("triple rule out"). Although MDCT has been instrumental in the advancement of cardiac imaging, there are still limitations in patients with high or irregular heart rates. Newer MDCT scanner generations hold promise to improve some of these limitations for noninvasive cardiac imaging. The evaluation of coronary artery stenosis remains the primary clinical indication for cardiac computed tomography angiography. However, the use of MDCT for simultaneous assessment of coronary artery stenosis, atherosclerotic plaque formation, ventricular function, myocardial perfusion, and viability with a single modality is under intense investigation. Recent technical developments hold promise for accomplishing this goal and establishing MDCT as a comprehensive stand-alone test for integrative imaging of coronary heart disease.
Collapse
|
22
|
Nakazato R, Tamarappoo BK, Smith TW, Cheng VY, Dey D, Shmilovich H, Gutstein A, Gurudevan S, Hayes SW, Thomson LE, Friedman JD, Berman DS. Assessment of left ventricular regional wall motion and ejection fraction with low-radiation dose helical dual-source CT: Comparison to two-dimensional echocardiography. J Cardiovasc Comput Tomogr 2011; 5:149-57. [DOI: 10.1016/j.jcct.2011.01.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2010] [Revised: 12/15/2010] [Accepted: 01/18/2011] [Indexed: 11/25/2022]
|
23
|
Lim SJ, Choo KS, Park YH, Kim JS, Kim JH, Chun KJ, Jeong DW. Assessment of left ventricular function and volume in patients undergoing 128-slice coronary CT angiography with ECG-based maximum tube current modulation: a comparison with echocardiography. Korean J Radiol 2011; 12:156-62. [PMID: 21430931 PMCID: PMC3052605 DOI: 10.3348/kjr.2011.12.2.156] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2010] [Accepted: 12/17/2010] [Indexed: 01/28/2023] Open
Abstract
Objective To compare multi-detector CT (MDCT) using 128-slice coronary CT angiography (Definition AS+, Siemens Medical Solution, Forchheim, Germany) with ECG-based maximum tube current modulation with echocardiography for the determination of left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV), as well as assessing coronary artery image quality and patient radiation dose. Materials and Methods Thirty consecutive patients (M:F = 20:10; mean age, 57.9 ± 11.4 years) were referred for MDCT for evaluation of atypical chest pain. EF, EDV and ESV were determined for both MDCT and echocardiography, and the correlation coefficients were assessed. Coronary artery segment subjective image quality (1, excellent; 4, poor) and radiation dose were recorded. Results Left ventricular EF, EDV, and ESV were calculated by MDCT and echocardiography and the comparison showed a significant correlation with those estimated by echocardiography (p < 0.05). Consistently, the LVEFs calculated by MDCT and echocardiography were not statistically different. However, LV, EDV and ESV from MDCT were statistically higher than those from echocardiography (p < 0.05). The average image quality score of the coronary artery segment was 1.10 and the mean patient radiation dose was 3.99 ± 1.85 mSv. Conclusion Although LV volume was overestimated by MDCT, MDCT provides comparable results to echocardiography for LVEF and LVV, with a low radiation dose.
Collapse
Affiliation(s)
- Soo Jin Lim
- Department of Cardiology, Kim Hae Jungang Hospital, Gyeongsangnam-do 621-921, Korea
| | | | | | | | | | | | | |
Collapse
|
24
|
Ko YJ, Kim SS, Park WJ, Jeong JO, Ko SM. Comparison of global left ventricular function using 20 phases with 10-phase reconstructions in multidetector-row computed tomography. Int J Cardiovasc Imaging 2011; 28:603-11. [PMID: 21359518 DOI: 10.1007/s10554-011-9828-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Accepted: 02/01/2011] [Indexed: 11/28/2022]
Abstract
To compare the measurement of global left-ventricular (LV) function parameters of 64-slice multidetector-row computed tomography (MDCT) between 20- and 10-reconstruction phases. Fifty five patients with suspected or known coronary artery disease underwent 64-slice MDCT. LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were measured from MDCT data sets using threshold-based volume segmentation and reconstruction at every 5% (20 phases) and 10% (10 phases) step through the R-R interval. These global functional parameters were compared to those obtained via two-dimensional transthoracic echocardiography (2D-TTE), considering the reference standard. The required time for CT data analysis was checked. Agreement for parameters of LV global function was determined using Pearson's correlation coefficient (r) and Bland-Altman analysis. LV volumes (EDV(-5%) 87.5 ± 17.1 ml, EDV(-10%) 87.7 ± 16.3 ml; ESV(-5%) 32.4 ± 10.6 ml, ESV(-10%) 31.9 ± 9.9 ml; SV(-5%) 55.1 ± 10.5 ml, SV(-10%) 55.8 ± 9.9 ml; mean ± SD) and EF (EF(-5%) 63.4 ± 6.2%, EF(-10%) 63.9 ± 5.8%) did not differ significantly between the 20- and 10 phase reconstructions, and evidenced good to excellent correlation (r = 0.786-0.896, all P < 0.001) with the 2D-TTE results. The mean required time for CT data analysis in the 20- and 10 phase reconstructions were 15.5 ± 4.0 and 7.3 ± 2.5 min. Within MDCT, using 10-phase image reconstruction is sufficient to evaluate LV volumes and EF, and is also more time-effective than 20-phase reconstruction.
Collapse
Affiliation(s)
- Yeon-jee Ko
- Department of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, 33 Munhwa-ro, Jung-gu, Daejeon 301-721, Korea
| | | | | | | | | |
Collapse
|
25
|
Malagò R, Tavella D, Mantovani W, D’Onofrio M, Caliari G, Pezzato A, Nicolì L, Benussi P, Pozzi Mucelli R. MDCT coronary angiography vs 2D echocardiography for the assessment of left ventricle functional parameters. Radiol Med 2011; 116:505-20. [DOI: 10.1007/s11547-011-0615-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2010] [Accepted: 03/05/2010] [Indexed: 10/18/2022]
|
26
|
|
27
|
|
28
|
Celebi AS, Yalcin H, Yalcin F. Current cardiac imaging techniques for detection of left ventricular mass. Cardiovasc Ultrasound 2010; 8:19. [PMID: 20515461 PMCID: PMC2896933 DOI: 10.1186/1476-7120-8-19] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2010] [Accepted: 06/01/2010] [Indexed: 12/19/2022] Open
Abstract
Estimation of left ventricular (LV) mass has both prognostic and therapeutic value independent of traditional risk factors. Unfortunately, LV mass evaluation has been underestimated in clinical practice. Assessment of LV mass can be performed by a number of imaging modalities. Despite inherent limitations, conventional echocardiography has fundamentally been established as most widely used diagnostic tool. 3-dimensional echocardiography (3DE) is now feasible, fast and accurate for LV mass evaluation. 3DE is also superior to conventional echocardiography in terms of LV mass assessment, especially in patients with abnormal LV geometry. Cardiovascular magnetic resonance (CMR) and cardiovascular computed tomography (CCT) are currently performed for LV mass assessment and also do not depend on cardiac geometry and display 3-dimensional data, as well. Therefore, CMR is being increasingly employed and is at the present standard of reference in the clinical setting. Although each method demonstrates advantages over another, there are also disadvantages to receive attention. Diagnostic accuracy of methods will also be increased with the introduction of more advanced systems. It is also likely that in the coming years new and more accurate diagnostic tests will become available. In particular, CMR and CCT have been intersecting hot topic between cardiology and radiology clinics. Thus, good communication and collaboration between two specialties is required for selection of an appropriate test.
Collapse
|
29
|
Seneviratne SK, Truong QA, Bamberg F, Rogers IS, Shapiro MD, Schlett CL, Chae CU, Cury R, Abbara S, Brady TJ, Nagurney JT, Hoffmann U. Incremental diagnostic value of regional left ventricular function over coronary assessment by cardiac computed tomography for the detection of acute coronary syndrome in patients with acute chest pain: from the ROMICAT trial. Circ Cardiovasc Imaging 2010; 3:375-83. [PMID: 20484542 DOI: 10.1161/circimaging.109.892638] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The incremental value of regional left ventricular function (LVF) over coronary assessment to detect acute coronary syndrome (ACS) is uncertain. METHODS AND RESULTS We analyzed 356 patients (mean age, 53+/-12 years; 62% men) with acute chest pain and inconclusive initial emergency department evaluation. Patients underwent 64-slice contrast-enhanced cardiac computed tomography before hospital admission. Caregivers and patients remained blinded to the results. Regional LVF and presence of coronary atherosclerotic plaque and significant stenosis (>50%) were separately assessed by 2 independent readers. Incremental value of regional LVF to predict ACS was determined in the entire cohort and in subgroups of patients with nonobstructive coronary artery disease, inconclusive assessment for stenosis (defined as inability to exclude significant stenosis due to calcium or motion), and significant stenosis. During their index hospitalization, 31 patients were ultimately diagnosed with ACS (8 myocardial infarction, 22 unstable angina), of which 74% (23 patients) had regional LV dysfunction. Adding regional LVF resulted in a 10% increase in sensitivity to detect ACS by cardiac computed tomography (87%; 95% confidence interval, 70% to 96%) and significantly improved the overall accuracy (c-statistic: 0.88 versus 0.94 and 0.79 versus 0.88, for extent of plaque and presence of stenosis, respectively; both P<0.03). The diagnostic accuracy of regional LVF for detection of ACS has 89% sensitivity and 86% specificity in patients with significant stenosis (n=33) and 60% sensitivity and 86% specificity in patients with inconclusive coronary computed tomographic angiography (n=33). CONCLUSIONS Regional LVF assessment at rest improves diagnostic accuracy for ACS in patients with acute chest pain, especially in those with coronary artery disease and thus may be helpful to guide further management in patients at intermediate risk for ACS.
Collapse
Affiliation(s)
- Sujith K Seneviratne
- Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, 165 Charles River Plaza, Boston, MA 02114, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Schwaiger M, Ziegler SI, Nekolla SG. PET/CT challenge for the non-invasive diagnosis of coronary artery disease. Eur J Radiol 2010; 73:494-503. [PMID: 20206454 DOI: 10.1016/j.ejrad.2009.12.025] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2009] [Accepted: 12/15/2009] [Indexed: 10/19/2022]
Abstract
This review will focus on the clinical potential of PET/CT for the characterization of cardiovascular diseases. We describe the technical challenges of combining instrumentation with very different imaging performance and discuss the clinical applications in the field of cardiology.
Collapse
Affiliation(s)
- Markus Schwaiger
- Klinikum rechts der Isar, Technische Universität München, Nuklearmedizinische Klinik und Poliklinik, München, Germany
| | | | | |
Collapse
|
31
|
de Graaf F, Schuijf J, Delgado V, van Velzen J, Kroft L, de Roos A, Jukema J, van der Wall E, Bax J. Clinical Application of CT Coronary Angiography: State of the Art. Heart Lung Circ 2010; 19:107-16. [DOI: 10.1016/j.hlc.2009.11.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Accepted: 11/24/2009] [Indexed: 01/17/2023]
|
32
|
Ko SM, Kim YJ, Park JH, Choi NM. Assessment of left ventricular ejection fraction and regional wall motion with 64-slice multidetector CT: a comparison with two-dimensional transthoracic echocardiography. Br J Radiol 2010; 83:28-34. [PMID: 19546180 PMCID: PMC3487259 DOI: 10.1259/bjr/38829806] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2008] [Revised: 02/15/2009] [Accepted: 02/19/2009] [Indexed: 12/20/2022] Open
Abstract
The aim of this study was to compare the measurement of left ventricular ejection fraction (LVEF) and regional wall motion using 64-slice multidetector CT (MDCT) with that using two-dimensional transthoracic echocardiography (2D-TTE) in a heterogeneous patient population. In 126 patients with angina pectoris, acute myocardial infarction, chronic myocardial infarction, atypical chest pain without coronary artery disease or valvular heart disease, 64-slice MDCT was performed using retrospective electrocardiography gating without dose modulation. 20 phases of the cardiac cycle were analysed to identify the end-diastolic and end-systolic phases and to assess regional LV wall motion. For these measurements, 2D-TTE served as the reference standard. MDCT and 2D-TTE were performed within 10 days of each other. An excellent correlation between MDCT and 2D-TTE was shown for the evaluation of LVEF (59.2+/-11% vs 57.9+/-10%, respectively; r = 0.87). LVEF was slightly overestimated by MDCT, when compared with 2D-TTE, by an average of 1.4+/-5.6%. Good agreement was obtained between the use of the two techniques, with 94% of the segments scored identically on both modalities (kappa = 0.70). MDCT had a sensitivity of 97% and a specificity of 82% when compared with 2D-TTE as the reference standard. In conclusion, the use of 64-slice MDCT can provide comparable results to those using 2D-TTE for LVEF and regional wall motion assessment in a heterogeneous population.
Collapse
Affiliation(s)
- S-M Ko
- Department of Radiology, Konkuk University Hospital, Konkuk University School of Medicine, Seoul, Korea.
| | | | | | | |
Collapse
|
33
|
Fuller CD, Scarbrough TJ, Sonke JJ, Rasch CRN, Choi M, Ting JY, Wang SJ, Papanikolaou N, Rosenthal DI. Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis. Phys Med Biol 2009; 54:7401-15. [PMID: 19934488 PMCID: PMC5343752 DOI: 10.1088/0031-9155/54/24/010] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
We sought to characterize interchangeability and agreement between cone-beam computed tomography (CBCT) and digital stereoscopic kV x-ray (KVX) acquisition, two methods of isocenter positional verification currently used for IGRT of head and neck cancers (HNC). A cohort of 33 patients were near-simultaneously imaged by in-room KVX and CBCT. KVX and CBCT shifts were suggested using manufacturer software for the lateral (X), vertical (Y) and longitudinal (Z) dimensions. Intra-method repeatability, systematic and random error components were calculated for each imaging modality, as were recipe-based PTV expansion margins. Inter-method agreement in each axis was compared using limits of agreement (LOA) methodology, concordance analysis and orthogonal regression. 100 daily positional assessments were performed before daily therapy in 33 patients with head and neck cancer. Systematic error was greater for CBCT in all axes, with larger random error components in the Y- and Z-axis. Repeatability ranged from 9 to 14 mm for all axes, with CBCT showing greater repeatability in 2/3 axes. LOA showed paired shifts to agree 95% of the time within +/-11.3 mm in the X-axis, +/-9.4 mm in the Y-axis and +/-5.5 mm in the Z-axis. Concordance ranged from 'mediocre' to 'satisfactory'. Proportional bias was noted between paired X- and Z-axis measures, with a constant bias component in the Z-axis. Our data suggest non-negligible differences in software-derived CBCT and KVX image-guided directional shifts using formal method comparison statistics.
Collapse
Affiliation(s)
- Clifton D Fuller
- Department of Radiation Oncology, University of Texas Health Science Center-San Antonio, San Antonio, TX, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Bastarrika G, Lee YS, Huda W, Ruzsics B, Costello P, Schoepf UJ. CT of coronary artery disease. Radiology 2009; 253:317-38. [PMID: 19864526 DOI: 10.1148/radiol.2532081738] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Technical innovation is rapidly improving the clinical utility of cardiac computed tomography (CT) and will increasingly address current technical limitations, especially the association of this test with relatively high levels of radiation. Guidelines for appropriate indications are in place and are evolving, with an increasing evidence base to ensure the appropriate use of this modality. New technologies and new applications, such as myocardial perfusion imaging and dual-energy CT, are being explored and are widening the scope of coronary CT angiography from mere coronary artery assessment to the integrative analysis of cardiac morphology, function, perfusion, and viability. The scientific evaluation of coronary CT angiography has left the stage of feasibility testing and increasingly, evidence-based data are accumulating on outcomes, prognosis, and cost-effectiveness. In this review, these developments will be discussed in the context of current pivotal transitions in cardiovascular disease management and their potential influence on the current role and future fate of coronary CT angiography will be examined.
Collapse
Affiliation(s)
- Gorka Bastarrika
- Department of Radiology and Division of Cardiology, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC 29401, USA
| | | | | | | | | | | |
Collapse
|
35
|
Natsume T, Amano T, Takehara Y, Ichihara T, Takeda K, Sakuma H. Quantitative assessment of regional systolic and diastolic functions and temporal heterogeneity of myocardial contraction in patients with myocardial infarction using cine magnetic resonance imaging and Fourier fitting. Magn Reson Imaging 2009; 27:1440-6. [DOI: 10.1016/j.mri.2009.05.043] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2009] [Revised: 05/09/2009] [Accepted: 05/10/2009] [Indexed: 01/20/2023]
|
36
|
|
37
|
Pflederer T, Ho K, Anger T, Krähner R, Ropers D, Muschiol G, Renz A, Daniel W, Achenbach S. Assessment of regional left ventricular function by Dual Source Computed Tomography: Interobserver variability and validation to laevocardiography. Eur J Radiol 2009; 72:85-91. [DOI: 10.1016/j.ejrad.2008.06.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2007] [Revised: 05/28/2008] [Accepted: 06/03/2008] [Indexed: 10/21/2022]
|
38
|
Akram K, Anderson HD, Voros S. Quantification of Left Ventricular Parameters Obtained by Automated Software for 64-Slice Multidetector Computed Tomography and Comparison with Magnetic Resonance Imaging. Cardiovasc Intervent Radiol 2009; 32:1154-60. [PMID: 19771473 DOI: 10.1007/s00270-009-9706-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2009] [Accepted: 08/11/2009] [Indexed: 10/20/2022]
|
39
|
Left Ventricular Function Can Reliably be Assessed From Dual-Source CT Using ECG-Gated Tube Current Modulation. Invest Radiol 2009; 44:384-9. [DOI: 10.1097/rli.0b013e3181a4d874] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
40
|
Hoffmann U, Bamberg F. Is Computed Tomography Coronary Angiography the Most Accurate and Effective Noninvasive Imaging Tool to Evaluate Patients With Acute Chest Pain in the Emergency Department? Circ Cardiovasc Imaging 2009; 2:251-63; discussion 263. [DOI: 10.1161/circimaging.109.850347] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Udo Hoffmann
- From the Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass
| | - Fabian Bamberg
- From the Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass
| |
Collapse
|
41
|
Sarwar A, Shapiro MD, Nasir K, Nieman K, Nomura CH, Brady TJ, Cury RC. Evaluating global and regional left ventricular function in patients with reperfused acute myocardial infarction by 64-slice multidetector CT: A comparison to magnetic resonance imaging. J Cardiovasc Comput Tomogr 2009; 3:170-7. [DOI: 10.1016/j.jcct.2009.05.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2008] [Revised: 04/05/2009] [Accepted: 05/04/2009] [Indexed: 10/20/2022]
|
42
|
Arraiza M, Bastarrika G, Zudaire B, Pueyo J, Villanueva A. [Quantification of left ventricular function and mass in dual-source CT (DSCT).]. RADIOLOGIA 2009; 51:148-55. [PMID: 19286237 DOI: 10.1016/j.rx.2008.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2007] [Accepted: 01/21/2008] [Indexed: 12/20/2022]
Abstract
OBJECTIVES To evaluate the interobserver agreement in quantifying left ventricular function and mass and to assess the accuracy of conventional manual contour tracing compared to semiautomatic segmentation analysis software. MATERIAL AND METHODS Twenty consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Two different multiphase image reconstructions were done in 5% steps throughout the entire cardiac cycle (0-95% of the R-R interval) with effective slice thickness of 1mm in the axial plane and 8mm in the short-axis orientation. Left ventricular function and mass were calculated by two independent observers, tracing endocardial and epicardial borders manually and using a semiautomatic software tool (Circulation II, Siemens). Ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), cardiac output (CO), and myocardial mass were evaluated by two independent observers blind to each other's assessments. The interobserver agreement and the reliability of the different segmentation methods were calculated. The time required for manual contouring and semiautomatic contour tracing was also registered. RESULTS We found an excellent correlation (r>0.94; p<0.05) between the two independent observers for the quantification of left ventricular function and mass. Left ventricular functional parameters derived from semiautomatic contour software and conventional manual tracing method were not significantly different (p>0.05). The semiautomatic contour detection algorithm overestimated LV mass significantly compared with the manual contouring method (mean difference 29.45+/-1.64g; p<0.05). The time needed to calculate these parameters with the semiautomatic tool was significantly lower (248.85+/-99.8s) than with manual contouring (452.7+/-73.92s) (p<0.05). CONCLUSIONS Interobserver agreement for quantifying left ventricular function and mass using DSCT is excellent. Despite overestimating left ventricular mass, the semiautomatic software tool allows cardíac parameters to be quantified with the same reliability as the conventional manual method in half the time.
Collapse
Affiliation(s)
- M Arraiza
- Servicio de Radiología, Clínica Universidad de Navarra, Pamplona, España
| | | | | | | | | |
Collapse
|
43
|
Anatomy and Terminology for the Interpretation and Reporting of Cardiac MDCT: Part 2, CT Angiography, Cardiac Function Assessment, and Noncoronary and Extracardiac Findings. AJR Am J Roentgenol 2009; 192:584-98. [DOI: 10.2214/ajr.08.1178] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
44
|
Dennie CJ, Leipsic J, Brydie A. Canadian Association of Radiologists: Consensus Guidelines and Standards for Cardiac CT. Can Assoc Radiol J 2009; 60:19-34. [DOI: 10.1016/j.carj.2009.02.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Affiliation(s)
- Carole J. Dennie
- Department of Diagnostic Imaging, The Ottawa Hospital, Civic Campus, Ottawa, Ontario, Canada
| | - Jonathan Leipsic
- Department of Radiology, Division of Cardiology, University of British Columbia and St Paul's Hospital, Vancouver, British Columbia, Canada
| | - Alan Brydie
- Department of Radiology, Dalhousie University and Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada
| |
Collapse
|
45
|
Abstract
Recent years have witnessed a rapid development of multi-slice computed tomography (MSCT) technology. The number of detector rows has increased from 4-slices to the current availability of 64-slice and even 320-slice systems. In addition, images are acquired with thinner slices and faster rotation times resulting in substantially improved image quality and diagnostic accuracy. Simultaneously, effective dose reduction acquisition techniques have been developed allowing considerable reduction of the radiation dose. Conceivably, these advancements may allow further expansion of the use of MSCT beyond the visual assessment of the presence or absence of significant coronary artery disease. Indeed, a particular advantage of the technique is that in addition to evaluation of the coronary arteries it also allows assessment of cardiac structures and function. The purpose of the current review is to discuss several novel applications of cardiac MSCT, including stenosis quantification, atherosclerotic plaque imaging and prognostification as well as imaging of left ventricular function, aortic and mitral valve anatomy using state-of-the-art technology.
Collapse
|
46
|
Bastarrika G, Schoepf UJ. Evolving CT Applications in Ischemic Heart Disease. Semin Thorac Cardiovasc Surg 2008; 20:380-92. [DOI: 10.1053/j.semtcvs.2008.11.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/19/2008] [Indexed: 11/11/2022]
|
47
|
Usefulness of three-dimensional automated quantification of left ventricular mass, volume, and function by 64-slice computed tomography. J Cardiol 2008; 52:276-84. [DOI: 10.1016/j.jjcc.2008.07.021] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2008] [Revised: 07/23/2008] [Accepted: 07/28/2008] [Indexed: 12/26/2022]
|
48
|
Assessment of acute chest pain by CT. CURRENT CARDIOVASCULAR IMAGING REPORTS 2008. [DOI: 10.1007/s12410-008-0014-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
49
|
Spoeck A, Bonatti J, Friedrich GJ, Schachner T, Bonaros N, Feuchtner GM. Evaluation of Left Ventricular Function by 64-Multidetector Computed Tomography in Patients Undergoing Totally Endoscopic Coronary Artery Bypass Grafting. Heart Surg Forum 2008; 11:E218-24. [DOI: 10.1532/hsf98.20081046] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
50
|
Cury RC, Nieman K, Shapiro MD, Butler J, Nomura CH, Ferencik M, Hoffmann U, Abbara S, Jassal DS, Yasuda T, Gold HK, Jang IK, Brady TJ. Comprehensive assessment of myocardial perfusion defects, regional wall motion, and left ventricular function by using 64-section multidetector CT. Radiology 2008; 248:466-75. [PMID: 18641250 DOI: 10.1148/radiol.2482071478] [Citation(s) in RCA: 141] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the accuracy of 64-section multidetector computed tomography (CT) for the assessment of perfusion defects (PDs), regional wall motion (RWM), and global left ventricular (LV) function. MATERIALS AND METHODS All myocardial infarction (MI) patients signed informed consent. The IRB approved the study and it was HIPAA-compliant. Cardiac multidetector CT was performed in 102 patients (34 with recent acute MI and 68 without). Multidetector CT images were analyzed for myocardial PD, RWM abnormalities, and LV function. Global LV function and RWM were compared with transthoracic echocardiography (TTE) by using multidetector CT. PD was detected by using multidetector CT and was correlated with cardiac biomarkers and single photon emission CT (SPECT) myocardial perfusion imaging. Multidetector CT diagnosis of acute MI was made on the basis of matching the presence of PD with RWM abnormalities compared with clinical evaluation. RESULTS Correlation between multidetector CT and TTE for global function (r = 0.68) and RWM (kappa = 0.79) was good. The size of PD on multidetector CT had a moderate correlation against SPECT (r = 0.48, -7% +/- 9). There was good to excellent correlation between cardiac biomarkers and the percentage infarct size by using multidetector CT (r = 0.82 for creatinine phosphokinase, r = 0.76 for creatinine phosphokinase of the muscle band, and r = 0.75 for troponin). For detection of acute MI in patients, multidetector CT sensitivity was 94% (32 of 34) and specificity was 97% (66 of 68). Multidetector CT had an excellent interobserver reliability for ejection fraction quantification (r = 0.83), as compared with TTE (r = 0.68). CONCLUSION Patients with acute MI can be identified by using multidetector CT on the basis of RWM abnormalities and PD.
Collapse
Affiliation(s)
- Ricardo C Cury
- Department of Radiology, Cardiac MR-PET-CT Program, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge St, Suite 400, Boston, MA 02114, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|