1
|
Contrella BN, Khaja MS, Majdalany BS, Kim CY, Kalva SP, Beck AW, Browne WF, Clough RE, Ferencik M, Fleischman F, Gunn AJ, Hickey SM, Kandathil A, Kim KM, Monroe EJ, Ochoa Chaar CI, Scheidt MJ, Smolock AR, Steenburg SD, Waite K, Pinchot JW, Steigner ML. ACR Appropriateness Criteria® Thoracoabdominal Aortic Aneurysm or Dissection: Treatment Planning and Follow-Up. J Am Coll Radiol 2023; 20:S265-S284. [PMID: 37236748 DOI: 10.1016/j.jacr.2023.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 02/27/2023] [Indexed: 05/28/2023]
Abstract
As the incidence of thoracoabdominal aortic pathology (aneurysm and dissection) rises and the complexity of endovascular and surgical treatment options increases, imaging follow-up of patients remains crucial. Patients with thoracoabdominal aortic pathology without intervention should be monitored carefully for changes in aortic size or morphology that could portend rupture or other complication. Patients who are post endovascular or open surgical aortic repair should undergo follow-up imaging to evaluate for complications, endoleak, or recurrent pathology. Considering the quality of diagnostic data, CT angiography and MR angiography are the preferred imaging modalities for follow-up of thoracoabdominal aortic pathology for most patients. The extent of thoracoabdominal aortic pathology and its potential complications involve multiple regions of the body requiring imaging of the chest, abdomen, and pelvis in most patients. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Collapse
Affiliation(s)
| | | | - Bill S Majdalany
- Panel Chair, University of Vermont Medical Center, Burlington, Vermont
| | - Charles Y Kim
- Panel Chair, Duke University Medical Center, Durham, North Carolina
| | - Sanjeeva P Kalva
- Panel Vice-Chair, Massachusetts General Hospital, Boston, Massachusetts
| | - Adam W Beck
- University of Alabama at Birmingham Medical Center, Birmingham, Alabama; Society for Vascular Surgery
| | | | - Rachel E Clough
- St Thomas' Hospital, King's College, School of Biomedical Engineering and Imaging Science, London, United Kingdom; Society for Cardiovascular Magnetic Resonance
| | - Maros Ferencik
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon; Society of Cardiovascular Computed Tomography
| | - Fernando Fleischman
- Keck School of Medicine of USC, Los Angeles, California; American Association for Thoracic Surgery
| | - Andrew J Gunn
- University of Alabama at Birmingham, Birmingham, Alabama
| | - Sean M Hickey
- David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California; American College of Emergency Physicians
| | - Asha Kandathil
- UT Southwestern Medical Center, Dallas, Texas; Commission on Nuclear Medicine and Molecular Imaging
| | - Karen M Kim
- University of Michigan, Ann Arbor, Michigan; The Society of Thoracic Surgeons
| | | | | | | | - Amanda R Smolock
- Froedtert & The Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Scott D Steenburg
- Indiana University School of Medicine and Indiana University Health, Indianapolis, Indiana; Committee on Emergency Radiology-GSER
| | - Kathleen Waite
- Duke University Medical Center, Durham, North Carolina, Primary care physician
| | - Jason W Pinchot
- Specialty Chair, University of Wisconsin, Madison, Wisconsin
| | | |
Collapse
|
2
|
Bianchi D, Conti M, Bissacco D, Domanin M, Trimarchi S, Auricchio F. Impact of thoracic endovascular aortic repair on aortic biomechanics: Integration of in silico and ex vivo analysis using porcine model. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3594. [PMID: 35340129 DOI: 10.1002/cnm.3594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 02/09/2022] [Accepted: 03/16/2022] [Indexed: 05/12/2023]
Abstract
Thoracic endovascular aortic repair (TEVAR) is widespread in clinical practice for treating aortic diseases but it has relevant systemic complications, such as increase of the cardiac workload due to post-TEVAR aortic stiffening, and local issues such as re-entry tears due to the tissue damage caused by endograft interaction. The present study aims to elucidate these aortic biomechanical mechanisms by coupling ex vivo and in silico analysis. By ex vivo tests, the pulse wave velocity before and after TEVAR is measured. Uni-axial tensile tests are performed to measure regional mechanical response of tissue samples, supplied as input data for the in silico analysis. Numerical analysis is finally performed to compute the wall stress induced by the stent-graft deployment and the arterial pressurization. The ex vivo results highlight an increase of baseline PWV by a mean .78 m/s or 12% after TEVAR with a 100 mm stent-graft (p <.013). In the in silico analysis, the average von Mises stress in the landing zone increases of about 15% and 20% using, respectively stent-graft with radial oversizing of 10% and 20%. This work shows the effectiveness of integrated framework to analyze the biomechanical post TEVAR mechanisms. Moreover, the obtained results quantify the effect of prosthesis selection on the stiffening of the aorta after TEVAR and on the local increase of the aortic wall stress that is proportional to the stent-graft oversizing.
Collapse
Affiliation(s)
- Daniele Bianchi
- Department of Civil Engineering and Architecture (DICAr), University of Pavia, Pavia, Italy
| | - Michele Conti
- Department of Civil Engineering and Architecture (DICAr), University of Pavia, Pavia, Italy
| | - Daniele Bissacco
- Department of Health and Community Sciences, University of Milan, Milan, Italy
- Operative Unit of Vascular Surgery, Fondazione IRCCS Ca' Grande Ospedale Maggiore Policlinico Milano, Milan, Italy
| | - Maurizio Domanin
- Department of Health and Community Sciences, University of Milan, Milan, Italy
- Operative Unit of Vascular Surgery, Fondazione IRCCS Ca' Grande Ospedale Maggiore Policlinico Milano, Milan, Italy
| | - Santi Trimarchi
- Department of Health and Community Sciences, University of Milan, Milan, Italy
- Operative Unit of Vascular Surgery, Fondazione IRCCS Ca' Grande Ospedale Maggiore Policlinico Milano, Milan, Italy
| | - Ferdinando Auricchio
- Department of Civil Engineering and Architecture (DICAr), University of Pavia, Pavia, Italy
| |
Collapse
|
3
|
Wang Q, Guo X, Brooks M, Chuen J, Poon EKW, Ooi A, Lim RP. MRI in CFD for chronic type B aortic dissection: Ready for prime time? Comput Biol Med 2022; 150:106138. [PMID: 36191393 DOI: 10.1016/j.compbiomed.2022.106138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/31/2022] [Accepted: 09/18/2022] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Better tools are needed for risk assessment of Type B aortic dissection (TBAD) to determine optimal treatment for patients with uncomplicated disease. Magnetic resonance imaging (MRI) has the potential to inform computational fluid dynamics (CFD) simulations for TBAD by providing individualised quantification of haemodynamic parameters, for assessment of complication risks. This systematic review aims to present an overview of MRI applications for CFD studies of TBAD. METHODS Following PRISMA guidelines, a search in Medline, Embase, and the Scopus Library identified 136 potentially relevant articles. Studies were included if they used MRI to inform CFD simulation in TBAD. RESULTS There were 20 articles meeting the inclusion criteria. 19 studies used phase contrast MRI (PC-MRI) to provide data for CFD flow boundary conditions. In 12 studies, CFD haemodynamic parameter results were validated against PC-MRI. In eight studies, geometric models were developed from MR angiography. In three studies, aortic wall or intimal flap motion data were derived from PC/cine MRI. CONCLUSIONS MRI provides complementary patient-specific information in CFD haemodynamic studies for TBAD that can be used for personalised care. MRI provides structural, dynamic and flow data to inform CFD for pre-treatment planning, potentially advancing its integration into clinical decision-making. The use of MRI to inform CFD in TBAD surgical planning is promising, however further validation and larger cohort studies are required.
Collapse
Affiliation(s)
- Qingdi Wang
- Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia.
| | - Xiaojing Guo
- Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia
| | - Mark Brooks
- Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia; School of Medicine, Deakin University, Melbourne, Australia
| | - Jason Chuen
- Department of Surgery, Austin Health, Heidelberg, VIC, 3084, Australia; Department of Surgery, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia
| | - Eric K W Poon
- Department of Medicine, St Vincent's Hospital, Melbourne Medical School, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia
| | - Andrew Ooi
- Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia
| | - Ruth P Lim
- Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia; Department of Surgery, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia; Department of Radiology, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Melbourne, VIC, 3010, Australia
| |
Collapse
|
4
|
Lv L, Li H, Wu Z, Zeng W, Hua P, Yang S. An artificial intelligence-based platform for automatically estimating time-averaged wall shear stress in the ascending aorta. EUROPEAN HEART JOURNAL. DIGITAL HEALTH 2022; 3:525-534. [PMID: 36710907 PMCID: PMC9779925 DOI: 10.1093/ehjdh/ztac058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 09/01/2022] [Accepted: 09/06/2022] [Indexed: 11/07/2022]
Abstract
Aims Aortopathies are a series of disorders requiring multiple indicators to assess risk. Time-averaged wall shear stress (TAWSS) is currently considered as the primary indicator of aortopathies progression, which can only be calculated by Computational Fluid Dynamics (CFD). However, CFD's complexity and high computational cost, greatly limit its application. The study aimed to construct a deep learning platform which could accurately estimate TAWSS in ascending aorta. Methods and results A total of 154 patients who had thoracic computed tomography angiography were included and randomly divided into two parts: training set (90%, n = 139) and testing set (10%, n = 15). TAWSS were calculated via CFD. The artificial intelligence (AI)-based model was trained and assessed using the dice coefficient (DC), normalized mean absolute error (NMAE), and root mean square error (RMSE). Our AI platform brought into correspondence with the manual segmentation (DC = 0.86) and the CFD findings (NMAE, 7.8773% ± 4.7144%; RMSE, 0.0098 ± 0.0097), while saving 12000-fold computational cost. Conclusion The high-efficiency and robust AI platform can automatically estimate value and distribution of TAWSS in ascending aorta, which may be suitable for clinical applications and provide potential ideas for CFD-based problem solving.
Collapse
Affiliation(s)
| | | | - Zonglv Wu
- Department of Cardio-Vascular Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, No. 107 Yan Jiang West Road, 510120 Guangzhou, China,Department of Cardiac Surgery, Guangzhou Women and Children's Medical Center, No. 9 Jinsui Road, 510623 Guangzhou, China
| | - Weike Zeng
- Department of Radiology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, No. 107 Yanjiang West Road, 510120 Guangzhou, China
| | - Ping Hua
- Corresponding author. Tel: +86 13 609716875, Fax: +86 20 81332199, (P.H.); Tel: +86 13926168990, Fax: +86 20 81332199, (S.R.)
| | - Songran Yang
- Corresponding author. Tel: +86 13 609716875, Fax: +86 20 81332199, (P.H.); Tel: +86 13926168990, Fax: +86 20 81332199, (S.R.)
| |
Collapse
|
5
|
Williamson PN, Docherty PD, Yazdi SG, Khanafer A, Kabaliuk N, Jermy M, Geoghegan PH. Review of the Development of Hemodynamic Modeling Techniques to Capture Flow Behavior in Arteries Affected by Aneurysm, Atherosclerosis, and Stenting. J Biomech Eng 2022; 144:1128816. [PMID: 34802061 DOI: 10.1115/1.4053082] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Indexed: 02/05/2023]
Abstract
Cardiovascular diseases (CVDs) are the leading cause of death in the developed world. CVD can include atherosclerosis, aneurysm, dissection, or occlusion of the main arteries. Many CVDs are caused by unhealthy hemodynamics. Some CVDs can be treated with the implantation of stents and stent grafts. Investigations have been carried out to understand the effects of stents and stent grafts have on arteries and the hemodynamic changes post-treatment. Numerous studies on stent hemodynamics have been carried out using computational fluid dynamics (CFD) which has yielded significant insight into the effect of stent mesh design on near-wall blood flow and improving hemodynamics. Particle image velocimetry (PIV) has also been used to capture behavior of fluids that mimic physiological hemodynamics. However, PIV studies have largely been restricted to unstented models or intra-aneurysmal flow rather than peri or distal stent flow behaviors. PIV has been used both as a standalone measurement method and as a comparison to validate the CFD studies. This article reviews the successes and limitations of CFD and PIV-based modeling methods used to investigate the hemodynamic effects of stents. The review includes an overview of physiology and relevant mechanics of arteries as well as consideration of boundary conditions and the working fluids used to simulate blood for each modeling method along with the benefits and limitations introduced.
Collapse
Affiliation(s)
- Petra N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Sina G Yazdi
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Adib Khanafer
- Vascular, Endovascular, and Renal Transplant Unit, Christchurch Hospital, Canterbury District Health Board, Riccarton Avenue, Christchurch 8053, New Zealand; Christchurch School of Medicine, University of Otago, Dunedin 9016, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Patrick H Geoghegan
- School of Life and Health Sciences, Aston University, Birmingham B4 7ET, UK; Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg 2006, South Africa
| |
Collapse
|
6
|
Investigations into the Potential of Using Open Source CFD to Analyze the Differences in Hemodynamic Parameters for Aortic Dissections (Healthy versus Stanford Type A and B). Ann Vasc Surg 2021; 79:310-323. [PMID: 34648855 DOI: 10.1016/j.avsg.2021.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/11/2021] [Accepted: 08/14/2021] [Indexed: 11/23/2022]
Abstract
BACKGROUND The objective of this study was to develop a method to evaluate the effects of an aortic dissection on hemodynamic parameters by conducting a comparison with that of a healthy (nondissected) aorta. Open-source software will be implemented, no proprietary software/application will be used to ensure accessorily and repeatability, in all the data analysis and processing. Computed tomography (CT) images of aortic dissection are used for the model geometry segmentation. Boundary conditions from literature are implemented to computational fluid dynamics (CFD) to analyze the hemodynamic parameters. METHODS A numerical simulation model was created by obtaining accurate 3-dimensional geometries of aortae from CT images. In this study, CT images of 8 cases of aortic dissection (Stanford type-A and type-B) and 3 cases of healthy aortae are used for the actual aorta model geometry segmentation. These models were exported into an open-source CFD software, OpenFOAM, where a simplified pulsating flow was simulated by controlling the flow pressure. Ten cycles of the pulsatile flow (0.50 sec/cycle) conditions, totaling 5 sec, were calculated. RESULTS The pressure distribution, wall shear stress (WSS) and flow velocity streamlines within the aorta and the false lumen were calculated and visualized. It was found that the flow velocity and WSS had a high correlation in high WSS areas of the intermittent layer between the true and false lumen. Most of the Stanford type-A dissections in the study showed high WSS, over 38 Pa, at the systole phase. This indicates that the arterial walls in type-A dissections are more likely to be damaged with pulsatile flow. CONCLUSIONS Using CFD to estimate localized high WSS areas may help in deciding to treat a type-A or B dissection with a stent graft to prevent a potential rupture.
Collapse
|
7
|
Rauh P, Benk C, Beyersdorf F, Russe M. Determination of local flow ratios and velocities in a femoral venous cannula with computational fluid dynamics and 4D flow-sensitive magnetic resonance imaging: A method validation. Artif Organs 2020; 45:506-515. [PMID: 33185904 DOI: 10.1111/aor.13859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 09/09/2020] [Accepted: 10/08/2020] [Indexed: 11/28/2022]
Abstract
Cannulas with multi-staged side holes are the method of choice for femoral cannulation in extracorporeal therapies today. A variety of differently designed products is available on the market. While the preferred tool for the performance assessment of such cannulas are pressure-flow curves, little is known about the flow and velocity distribution. Within this work flow and velocity patterns of a femoral venous cannula with multi-staged side holes were investigated. A mock circulation loop for cannula performance evaluation was built and reproduced using a computer-aided design system. With computational fluid dynamics, volume flows and fluid velocities were determined quantitatively and visually with hole-based precision. In order to ensure the correctness of the flow simulation, the results were subsequently validated by determining the same parameters with four-dimensional flow-sensitive magnetic resonance imaging. Measurement data and numerical solution differed 7% on average throughout the data set for the examined parameters. The highest inflow and velocity were detected at the most proximal holes, where half of the total volume flow enters the cannula. At every hole stage a Y-shaped inflow profile was detected, forming a centered stream in the middle of the cannula. Simultaneously, flow separation creates zones with significant lower flow velocities. Numerical simulation, validated with four-dimensional flow-sensitive magnetic resonance imaging, is a valuable tool to examine flow and velocity distributions of femoral venous cannulas with hole-based accuracy. Flow and velocity distribution in such cannulas are not ideal. Based on this work future cannulas can be effectively optimized.
Collapse
Affiliation(s)
- Patrick Rauh
- Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Research & Development, Xenios AG, Heilbronn, Germany
| | - Christoph Benk
- Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Department of Cardiovascular Surgery, Heart Center University Freiburg, Freiburg, Germany
| | - Friedhelm Beyersdorf
- Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Department of Cardiovascular Surgery, Heart Center University Freiburg, Freiburg, Germany
| | - Maximilian Russe
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
8
|
Midulla M, Moreno R, Negre-Salvayre A, Beregi JP, Haulon S, Loffroy R, Dake M, Rousseau H. Impact of Thoracic Endografting on the Hemodynamics of the Native Aorta: Pre- and Postoperative Assessments of Wall Shear Stress and Vorticity Using Computational Fluid Dynamics. J Endovasc Ther 2020; 28:63-69. [PMID: 33025866 DOI: 10.1177/1526602820959662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To quantify the hemodynamic consequences of thoracic endovascular aortic repair (TEVAR) by comparing the preoperative and postoperative wall shear stress (WSS) and vorticity profiles on computational fluid dynamics (CFD) simulations. MATERIALS AND METHODS The pre- and postoperative computed tomography (CT) scans from 20 consecutive patients (median age 69 years, range 20-87) treated for different thoracic aortic pathologies (11 aneurysms, 5 false aneurysms, 3 penetrating ulcers, and 1 traumatic aortic rupture) were segmented to construct patient-specific CFD models using a meshless code. The simulations were run over the cardiac cycle, and the WSS and vorticity values measured at the proximal and distal landing zones were compared. RESULTS The CFD runs provided 4-dimensional simulations of blood flow in all patients. WSS and vorticity profiles at the proximal landing zone (located in zones 0-3 in 15 patients) varied in 18 and 20 of the cases, respectively; WSS was increased in 11 cases and the vorticity in 9. Pre- and postoperative WSS median values were 4.19 and 4.90 Pa, respectively. Vorticity median values were 40.38 and 39.17 Hz, respectively. CONCLUSION TEVAR induces functional alterations in the native thoracic aorta, though the prognostic significance of these changes is still unknown. CFD appears to be a valuable tool to explore aortic hemodynamics, and its application in a larger series would help define a predictive role for these hemodynamic assessments.
Collapse
Affiliation(s)
- Marco Midulla
- Department of Diagnostic and Therapeutic Radiology, Center for Mini-Invasive Image-Guided Therapies, Centre Hospitalier Universitaire de Dijon, Université de Bourgogne Franche-Comté, Dijon, France
| | | | | | | | - Stéphan Haulon
- Aortic Center, Hopital Marie-Lannelongue, Groupe Hospitalier Paris Saint Joseph, Paris, France
| | - Romaric Loffroy
- Department of Diagnostic and Therapeutic Radiology, Center for Mini-Invasive Image-Guided Therapies, Centre Hospitalier Universitaire de Dijon, Université de Bourgogne Franche-Comté, Dijon, France
| | - Michael Dake
- Health Sciences, University of Arizona, Tucson, AZ, USA
| | - Hervé Rousseau
- INSERM, UMR 1048, I2MC, Toulouse, France.,Department of Radiology, CHU Rangueil, Nîmes, France
| |
Collapse
|
9
|
Zaccaria A, Migliavacca F, Pennati G, Petrini L. Modeling of braided stents: Comparison of geometry reconstruction and contact strategies. J Biomech 2020; 107:109841. [DOI: 10.1016/j.jbiomech.2020.109841] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 04/21/2020] [Accepted: 05/05/2020] [Indexed: 11/25/2022]
|
10
|
Jarral OA, Tan MKH, Salmasi MY, Pirola S, Pepper JR, O'Regan DP, Xu XY, Athanasiou T. Phase-contrast magnetic resonance imaging and computational fluid dynamics assessment of thoracic aorta blood flow: a literature review. Eur J Cardiothorac Surg 2020; 57:438-446. [PMID: 31638698 DOI: 10.1093/ejcts/ezz280] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 09/06/2019] [Accepted: 09/17/2019] [Indexed: 11/14/2022] Open
Abstract
The death rate from thoracic aortic disease is on the rise and represents a growing global health concern as patients are often asymptomatic before acute events, which have devastating effects on health-related quality of life. Biomechanical factors have been found to play a major role in the development of both acquired and congenital aortic diseases. However, much is still unknown and translational benefits of this knowledge are yet to be seen. Phase-contrast cardiovascular magnetic resonance imaging of thoracic aortic blood flow has emerged as an exceptionally powerful non-invasive tool enabling visualization of complex flow patterns, and calculation of variables such as wall shear stress. This has led to multiple new findings in the areas of phenotype-dependent bicuspid valve flow patterns, thoracic aortic aneurysm formation and aortic prosthesis performance assessment. Phase-contrast cardiovascular magnetic resonance imaging has also been used in conjunction with computational fluid modelling techniques to produce even more sophisticated analyses, by allowing the calculation of haemodynamic variables with exceptional temporal and spatial resolution. Translationally, these technologies may potentially play a major role in the emergence of precision medicine and patient-specific treatments in patients with aortic disease. This clinically focused review will provide a systematic overview of key insights from published studies to date.
Collapse
Affiliation(s)
- Omar A Jarral
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Matthew K H Tan
- Department of Surgery and Cancer, Imperial College London, London, UK
| | | | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, UK
| | - John R Pepper
- National Heart and Lung Institute, Imperial College London, London, UK
| | - Declan P O'Regan
- MRC London Institute of Medical Sciences, Imperial College London, London, UK
| | - Xiao Y Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Thanos Athanasiou
- Department of Surgery and Cancer, Imperial College London, London, UK
| |
Collapse
|
11
|
Computational Fluid Dynamics Modeling of Hemodynamic Parameters in the Human Diseased Aorta: A Systematic Review. Ann Vasc Surg 2020; 63:336-381. [DOI: 10.1016/j.avsg.2019.04.032] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 03/09/2019] [Accepted: 04/18/2019] [Indexed: 02/07/2023]
|
12
|
Munshi B, Parker LP, Norman PE, Doyle BJ. The application of computational modeling for risk prediction in type B aortic dissection. J Vasc Surg 2019; 71:1789-1801.e3. [PMID: 31831314 DOI: 10.1016/j.jvs.2019.09.032] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Accepted: 09/04/2019] [Indexed: 02/06/2023]
Abstract
OBJECTIVE New tools are urgently needed to help with surgical decision-making in type B aortic dissection (TBAD) that is uncomplicated at the time of initial presentation. This narrative review aims to answer the clinical question, Can computational modeling be used to predict risk in acute and chronic Stanford TBAD? METHODS The review (PROSPERO 2018 CRD42018104472) focused on risk prediction in TBAD. A comprehensive search of the Ovid MEDLINE database, using terms related to computational modeling and aortic dissection, was conducted to find studies of any form published between 1998 and 2018. Cohort studies, case series, and case reports of adults (older than 18 years) with computed tomography or magnetic resonance imaging diagnosis of TBAD were included. Computational modeling was applied in all selected studies. RESULTS There were 37 studies about computational modeling of TBAD identified from the search, and the findings were synthesized into a narrative review. Computational modeling can produce numerically calculated values of stresses, pressures, and flow velocities that are difficult to measure in vivo. Hemodynamic parameters-high or low wall shear stress, high pressure gradient between lumens during the cardiac cycle, and high false lumen flow rate-have been linked to the pathogenesis of branch malperfusion and aneurysm formation by numerous studies. Considering the major outcomes of end-organ failure, aortic rupture, and stabilization and remodeling, hypotheses have been generated about inter-relationships of measurable parameters in computational models with observable anatomic and pathologic changes, resulting in specific clinical outcomes. CONCLUSIONS There is consistency in study findings about computational modeling in TBAD, although a limited number of patients have been analyzed using various techniques. The mechanistic patterns of association found in this narrative review should be investigated in larger cohort prospective studies to further refine our understanding. It highlights the importance of patient-specific computational hemodynamic parameters in clinical decision-making algorithms. The current challenge is to develop and to test a risk assessment method that can be used by clinicians for TBAD.
Collapse
Affiliation(s)
- Bijit Munshi
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Australia; Centre for Medical Research, The University of Western Australia, Perth, Australia; Medical School, The University of Western Australia, Perth, Australia; Department of Vascular Surgery, Fiona Stanley Hospital, Perth, Australia
| | - Louis P Parker
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Australia; Centre for Medical Research, The University of Western Australia, Perth, Australia; School of Engineering, The University of Western Australia, Perth, Australia
| | - Paul E Norman
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Australia; Centre for Medical Research, The University of Western Australia, Perth, Australia; Medical School, The University of Western Australia, Perth, Australia; Department of Vascular Surgery, Fiona Stanley Hospital, Perth, Australia
| | - Barry J Doyle
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Australia; Centre for Medical Research, The University of Western Australia, Perth, Australia; School of Engineering, The University of Western Australia, Perth, Australia.
| |
Collapse
|
13
|
Zhu Y, Zhan W, Hamady M, Xu XY. A pilot study of aortic hemodynamics before and after thoracic endovascular repair with a double-branched endograft. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2019. [DOI: 10.1016/j.medntd.2020.100027] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
14
|
Numerical simulation of haemodynamics of the descending aorta in the non-diabetic and diabetic rabbits. J Biomech 2019; 91:140-150. [DOI: 10.1016/j.jbiomech.2019.05.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 05/06/2019] [Accepted: 05/13/2019] [Indexed: 12/12/2022]
|
15
|
Auricchio F, Conti M, Romarowski RM, de Beaufort HW, Grassi V, Trimarchi S. Computational tools for thoracic endovascular aortic repair planning. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 2019. [DOI: 10.23736/s1824-4777.18.01386-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
16
|
Chen D, Wei J, Deng Y, Xu H, Li Z, Meng H, Han X, Wang Y, Wan J, Yan T, Xiong J, Tang X. Virtual stenting with simplex mesh and mechanical contact analysis for real-time planning of thoracic endovascular aortic repair. Theranostics 2018; 8:5758-5771. [PMID: 30555579 PMCID: PMC6276306 DOI: 10.7150/thno.28944] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 10/06/2018] [Indexed: 11/29/2022] Open
Abstract
In aortic endovascular repair, the prediction of stented vessel remodeling informs treatment plans and risk evaluation; however, there are no highly accurate and efficient methods to quantitatively simulate stented vessels. This study developed a fast virtual stenting algorithm to simulate stent-induced aortic remodeling to assist in real-time thoracic endovascular aortic repair planning. Methods: The virtual stenting algorithm was established based on simplex deformable mesh and mechanical contact analysis. The key parameters of the mechanical contact analysis were derived from mechanical tests on aortic tissue (n=40) and commonly used stent-grafts (n=6). Genetic algorithm was applied to select weighting parameters. Testing and validation of the algorithm were performed using pre- and post-treatment computed tomography angiography datasets of type-B aortic dissection cases (n=66). Results: The algorithm was efficient in simulating stent-induced aortic deformation (mean computing time on a single processor: 13.78±2.80s) and accurate at the morphological (curvature difference: 1.57±0.57%; cross-sectional area difference: 4.11±0.85%) and hemodynamic (similarity of wall shear stress-derived parameters: 90.16-90.94%) levels. Stent-induced wall deformation was higher (p<0.05) in distal stent-induced new entry cases than in successfully treated cases, and this deformation did not differ significantly among the different stent groups. Additionally, the high stent-induced wall deformation regions and the new-entry sites overlapped, indicating the usefulness of wall deformation to evaluate the risks of device-induced complications. Conclusion: The novel algorithm provided fast real-time and accurate predictions of stent-graft deployment with luminal deformation tracking, thereby potentially informing individualized stenting planning and improving endovascular aortic repair outcomes. Large, multicenter studies are warranted to extend the algorithm validation and determine stress-induced wall deformation cutoff values for the risk stratification of particular complications.
Collapse
|
17
|
Boyer L, Leguerney I, Randall Thomas S, Grand-Perret V, Lassau N, Pitre-Champagnat S. Study of the reliability of quantification methods of dynamic contrast-enhanced ultrasonography: numerical modeling of blood flow in tumor microvascularization. Phys Med Biol 2018; 63:17NT01. [PMID: 30136651 DOI: 10.1088/1361-6560/aad6ae] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Dynamic contrast-enhanced ultrasonography is a recent functional dynamic imaging technique that allows evaluation of the efficacy of anti-angiogenic treatments by quantifying changes in specific parameters of the tumor vasculature. Preclinical and clinical experimental studies now reveal the existence of sources of variability in the quantitative methods. In order to study the reliability of quantification methods (both semi-quantitative and quantitative), we have developed the first numerical model of blood flow and contrast agents in vascular networks with computational fluid dynamics Fluent software version 15.0 (ANSYS, France). We studied four vascular networks (1.84 × 10-3, 2.28 × 10-3, 2.4 × 10-3 and 2.54 × 10-3 ml) and four blood velocities (0.01, 0.02, 0.03 and 0.05 m s-1). For variations in tumor vascular volume the quantitative method is more sensitive, with variations of parameter perfusion of 25.7%, in contrast to variations of the semi-quantitative parameters between 14.9 and 19.5%. For changes in blood velocity the semi-quantitative method is more sensitive, with variation of the area under the enhancement curve (64%), the maximum of the enhancement curve (60%), and the slope of the enhancement curve (73%). The transit time parameters from the two quantitative methods were weakly sensitive to both blood volume and blood flow variations. This study is hopeful and may be extended to the treatment of more complex vascular networks, to approach clinical conditions, and to the evaluation of quantification methods in contrast imaging.
Collapse
Affiliation(s)
- Laure Boyer
- IR4M, Univ. Paris-Sud, CNRS, Université Paris-Saclay, Bâtiment 220, Rue Ampère, 91405 Orsay Cedex, France. Author to whom any correspondence should be addressed
| | | | | | | | | | | |
Collapse
|
18
|
Menichini C, Cheng Z, Gibbs RG, Xu XY. A computational model for false lumen thrombosis in type B aortic dissection following thoracic endovascular repair. J Biomech 2018; 66:36-43. [DOI: 10.1016/j.jbiomech.2017.10.029] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 09/28/2017] [Accepted: 10/27/2017] [Indexed: 10/18/2022]
|
19
|
Long Ko JK, Liu RW, Ma D, Shi L, Ho Yu SC, Wang D. Pulsatile hemodynamics in patient-specific thoracic aortic dissection models constructed from computed tomography angiography. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2017; 25:233-245. [PMID: 28234275 DOI: 10.3233/xst-17256] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE Thoracic aortic dissection (TAD) is considered one of the most catastrophic and non-traumatic cardiovascular diseases associated with high morbidity and mortality rates in clinical treatment. The purpose of this paper is to investigate the pulsatile hemodynamics changes throughout a cardiac cycle in a Stanford Type B TAD model with the aid of computational fluid dynamics (CFD) method. METHODS A patient-specific dissected aorta geometry was reconstructed from the three-dimensional (3D) computed tomography angiography (CTA) scanning. The realistic time-dependent pulsatile boundary conditions were prescribed for our 3D patient-specific TAD model. Blood was considered to be an incompressible, Newtonian fluid. The aortic wall was assumed to be rigid, and a no-slip boundary condition was applied at the wall. CFD simulations were processed using the finite volume (FV) method to investigate the pulsatile hemodynamics in terms of blood flow velocity, aortic wall pressure, wall shear stress and flow vorticity. In the experiments, blood velocity, pressure, wall shear stress and vorticity distributions were analyzed qualitatively and quantitatively. RESULTS The experimental results demonstrated a high wall shear stress and strong vertical flow at dissection initiation. The results also indicated that wall shear progressed along the false lumen, which is a possible cause of blood flow between aortic wall layers.
Collapse
Affiliation(s)
- Jacky Ka Long Ko
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
| | - Ryan Wen Liu
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
| | - Diya Ma
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
| | - Lin Shi
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
- Chow Yuk Ho Technology Center for Innovative Medicine, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
| | - Simon Chun Ho Yu
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
| | - Defeng Wang
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
- Research Center for Medical Image Computing, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong
- Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen, China
| |
Collapse
|
20
|
Nardi A, Avrahami I. Approaches for treatment of aortic arch aneurysm, a numerical study. J Biomech 2017; 50:158-165. [DOI: 10.1016/j.jbiomech.2016.11.038] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 11/02/2016] [Indexed: 10/20/2022]
|
21
|
van Bogerijen GHW, Auricchio F, Conti M, Lefieux A, Reali A, Veneziani A, Tolenaar JL, Moll FL, Rampoldi V, Trimarchi S. Aortic Hemodynamics After Thoracic Endovascular Aortic Repair, With Particular Attention to the Bird-Beak Configuration. J Endovasc Ther 2014; 21:791-802. [DOI: 10.1583/14-4778mr.1] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
22
|
Goubergrits L, Riesenkampff E, Yevtushenko P, Schaller J, Kertzscher U, Berger F, Kuehne T. Is MRI-Based CFD Able to Improve Clinical Treatment of Coarctations of Aorta? Ann Biomed Eng 2014; 43:168-76. [DOI: 10.1007/s10439-014-1116-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Accepted: 09/06/2014] [Indexed: 01/16/2023]
|
23
|
van Bogerijen GHW, van Herwaarden JA, Conti M, Auricchio F, Rampoldi V, Trimarchi S, Moll FL. Importance of dynamic aortic evaluation in planning TEVAR. Ann Cardiothorac Surg 2014; 3:300-6. [PMID: 24967170 DOI: 10.3978/j.issn.2225-319x.2014.04.05] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Accepted: 03/27/2014] [Indexed: 11/14/2022]
Abstract
Dynamic aortic evaluation in planning thoracic endovascular aortic repair (TEVAR) is important to provide optimal stent graft sizing. Static imaging protocols do not consider normal aortic dynamics and may lead to stent graft to aorta mismatch, causing stent graft related complications, such as type I endoleak and stent graft migration. Dynamic imaging can assist in accurate stent graft selection and sizing preoperatively, and evaluate stent graft performance during follow-up. To create new imaging technologies, integration of knowledge between diverse scientific fields is essential (i.e., engineering, informatics and medicine). Different dynamic imaging modalities, such as electrocardiographic-gated computed tomography angiography (ECG-gated CTA) and four-dimensional phase-contrast MRI (4D PC-MRI), are progressively investigated and implemented into clinical practice as important instruments in preoperative planning for TEVAR. In time, further application of dynamic imaging tools for preoperative screening and follow-up after TEVAR might lead to better outcomes for patients. The advances in dynamic imaging for evaluation of the thoracic aorta using new imaging modalities and their future perspectives are addressed in this manuscript.
Collapse
Affiliation(s)
- Guido H W van Bogerijen
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| | - Joost A van Herwaarden
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| | - Michele Conti
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| | - Ferdinando Auricchio
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| | - Vincenzo Rampoldi
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| | - Santi Trimarchi
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| | - Frans L Moll
- 1 Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands ; 2 Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy ; 3 Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Italy
| |
Collapse
|
24
|
Goubergrits L, Riesenkampff E, Yevtushenko P, Schaller J, Kertzscher U, Hennemuth A, Berger F, Schubert S, Kuehne T. MRI-based computational fluid dynamics for diagnosis and treatment prediction: clinical validation study in patients with coarctation of aorta. J Magn Reson Imaging 2014; 41:909-16. [PMID: 24723299 DOI: 10.1002/jmri.24639] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Accepted: 03/27/2014] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To reduce the need for diagnostic catheterization and optimize treatment in a variety of congenital heart diseases, magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) is proposed. However, data about the accuracy of CFD in a clinical context are still sparse. To fill this gap, this study compares MRI-based CFD to catheterization in the coarctation of aorta (CoA) setting. MATERIALS AND METHODS Thirteen patients with CoA were investigated by routine MRI prior to catheterization. 3D whole-heart MRI was used to reconstruct geometries and 4D flow-sensitive phase-contrast MRI was used to acquire flows. Peak systolic flows were simulated using the program FLUENT. RESULTS Peak systolic pressure drops in CoA measured by catheterization and CFD correlated significantly for both pre- and posttreatment measurements (pre: r = 0.98, p = 0.00; post: r = 0.87, p = 0.00). The pretreatment bias was -0.5 ± 3.33 mmHg (95% confidence interval -2.55 to 1.47 mmHg). CFD predicted a reduction of the peak systolic pressure drop after treatment that ranged from 17.6 ± 5.56 mmHg to 6.7 ± 5.58 mmHg. The posttreatment bias was 3.0 ± 2.91 mmHg (95% CI -1.74 to 5.43 mmHg). CONCLUSION Peak systolic pressure drops can be reliably calculated using MRI-based CFD in a clinical setting. Therefore, CFD might be an attractive noninvasive alternative to diagnostic catheterization.
Collapse
Affiliation(s)
- Leonid Goubergrits
- Biofluid Mechanics Laboratory, Charité-Universitätsmedizin, Berlin, Germany; Non-Invasive Cardiac Imaging in Congenital Heart Disease Unit, Charité-Universitätsmedizin, Berlin, and German Heart Institute, Berlin, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Evaluation of the hemodynamic effectiveness of aortic dissection treatments via virtual stenting. Int J Artif Organs 2014; 37:753-62. [PMID: 24811307 DOI: 10.5301/ijao.5000310] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/20/2013] [Indexed: 11/20/2022]
Abstract
Aortic dissection treatment varies for each patient and stenting is one of a number of approaches that are utilized to Stabilize the condition. Information regarding the hemodynamic forces in the aorta in dissected and virtually stented cases could support clinicians in their choices of treatment prior to medical intervention. Computational fluid dynamics coupled with lumped parameter models have shown promise in providing detailed information that could be used in the clinic; for this, it is necessary to develop personalized workflows in order to produce patient-specific simulations. In the present study, a case of pre- and post-stenting (virtual stent-graft) of an aortic dissection is investigated with a particular focus on the role of personalized boundary conditions. For each virtual case, velocity, pressure, energy loss, and wall shear stress values are evaluated and compared. The simulated single stent-graft only marginally reduced the pulse pressure and systemic energy loss. The double stent-graft results showed a larger reduction in pulse pressure and a 40% reduction in energy loss as well as a more physiological wall shear stress distribution.Regions of potential risk were highlighted. The methodology applied in the present study revealed detailed information about two possible surgical outcome cases and shows promise as both a diagnostic and an interventional tool.
Collapse
|
26
|
Wan Ab Naim WN, Ganesan PB, Sun Z, Chee KH, Hashim SA, Lim E. A perspective review on numerical simulations of hemodynamics in aortic dissection. ScientificWorldJournal 2014; 2014:652520. [PMID: 24672348 PMCID: PMC3932246 DOI: 10.1155/2014/652520] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Accepted: 12/05/2013] [Indexed: 11/30/2022] Open
Abstract
Aortic dissection, characterized by separation of the layers of the aortic wall, poses a significant challenge for clinicians. While type A aortic dissection patients are normally managed using surgical treatment, optimal treatment strategy for type B aortic dissection remains controversial and requires further evaluation. Although aortic diameter measured by CT angiography has been clinically used as a guideline to predict dilation in aortic dissection, hemodynamic parameters (e.g., pressure and wall shear stress), geometrical factors, and composition of the aorta wall are known to substantially affect disease progression. Due to the limitations of cardiac imaging modalities, numerical simulations have been widely used for the prediction of disease progression and therapeutic outcomes, by providing detailed insights into the hemodynamics. This paper presents a comprehensive review of the existing numerical models developed to investigate reasons behind tear initiation and progression, as well as the effectiveness of various treatment strategies, particularly the stent graft treatment.
Collapse
Affiliation(s)
- Wan Naimah Wan Ab Naim
- Department of Biomedical Engineering, Faculty of Engineering Building, University of Malaya, 50603 Kuala Lumpur, KL, Malaysia
| | - Poo Balan Ganesan
- Department of Mechanical Engineering, Faculty of Engineering Building, University of Malaya, 50603 Kuala Lumpur, KL, Malaysia
| | - Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, WA 6845, Australia
| | - Kok Han Chee
- Department of Medicine, Faculty of Medicine Building, University of Malaya, 50603 Kuala Lumpur, KL, Malaysia
| | - Shahrul Amry Hashim
- Department of Surgery, Faculty of Medicine Building, University of Malaya, 50603 Kuala Lumpur, KL, Malaysia
| | - Einly Lim
- Department of Biomedical Engineering, Faculty of Engineering Building, University of Malaya, 50603 Kuala Lumpur, KL, Malaysia
| |
Collapse
|
27
|
Preliminary computational hemodynamics study of double aortic aneurysms under multistage surgical procedures: an idealised model study. ScientificWorldJournal 2013; 2013:601470. [PMID: 24348172 PMCID: PMC3855976 DOI: 10.1155/2013/601470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Accepted: 09/19/2013] [Indexed: 11/17/2022] Open
Abstract
Double aortic aneurysm (DAA) falls under the category of multiple aortic aneurysms. Repair is generally done through staged surgery due to low invasiveness. In this approach, one aneurysm is cured per operation. Therefore, two operations are required for DAA. However, post-first-surgery rupture cases have been reported. Although the problems involved with managing staged surgery have been discussed for more than 30 years, investigation from a hemodynamic perspective has not been attempted. Hence, this is the first computational fluid dynamics approach to the DAA problem. Three idealized geometries were prepared: presurgery, thoracic aortic aneurysm (TAA) cured, and abdominal aortic aneurysm (AAA) cured. By applying identical boundary conditions for flow rate and pressure, the Navier-Stokes equation and continuity equations were solved under the Newtonian fluid assumption. Average pressure in TAA was increased by AAA repair. On the other hand, average pressure in AAA was decreased after TAA repair. Average wall shear stress was decreased at the peak in post-first-surgery models. However, the wave profile of TAA average wall shear stress was changed in the late systole phase after AAA repair. Since the average wall shear stress in the post-first-surgery models decreased and pressure at TAA after AAA repair increased, the TAA might be treated first to prevent rupture.
Collapse
|
28
|
The impact of MRI-based inflow for the hemodynamic evaluation of aortic coarctation. Ann Biomed Eng 2013; 41:2575-87. [PMID: 23907337 DOI: 10.1007/s10439-013-0879-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Accepted: 07/24/2013] [Indexed: 10/26/2022]
Abstract
Aortic coarctation (CoA) accounting for 3-11% of congenital heart disease can be successfully treated. Long-term results, however, have revealed decreased life expectancy associated with abnormal hemodynamics. Accordingly, an assessment of hemodynamics is the key factor in treatment decisions and successful long-term results. In this study, 3D angiography whole heart (3DWH) and 4D phase-contrast magnetic resonance imaging (MRI) data were acquired. Geometries of the thoracic aorta with CoAs were reconstructed using ZIB-Amira software. X-ray angiograms were used to evaluate the post-treatment geometry. Computational fluid dynamics models in three patients were created to simulate pre- and post-treatment situations using the FLUENT program. The aim of the study was to investigate the impact of the inlet velocity profile (plug vs. MRI-based) with a focus on the peak systole pressure gradient and wall shear stress (WSS). Results show that helical flow at the aorta inlet can significantly affect the assessment of pressure drop and WSS. Simplified plug inlet velocity profiles significantly (p < 0.05) overestimate the pressure drop in pre- and post-treatment geometries and significantly (p < 0.05) underestimate surface-averaged WSS. We conclude that the use of the physiologically correct but time-expensive 4D MRI-based in vivo velocity profile in CFD studies may be an important step towards a patient-specific analysis of CoA hemodynamics.
Collapse
|
29
|
van Bogerijen GH, Tolenaar JL, Conti M, Auricchio F, Secchi F, Sardanelli F, Moll FL, van Herwaarden JA, Rampoldi V, Trimarchi S. Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease. AORTA (STAMFORD, CONN.) 2013; 1:171-181. [PMID: 26798690 PMCID: PMC4682739 DOI: 10.12945/j.aorta.2013.13-003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2013] [Accepted: 07/12/2013] [Indexed: 06/05/2023]
Abstract
In the past decade, thoracic endovascular aortic repair (TEVAR) has become the primary treatment option in descending aneurysm and dissection. The clinical outcome of this minimally invasive technique is strictly related to an appropriate patient/stent graft selection, hemodynamic interactions, and operator skills. In this context, a quantitative assessment of the biomechanical stress induced in the aortic wall due to the stent graft may support the planning of the procedure. Different techniques of medical imaging, like computed tomography or magnetic resonance imaging, can be used to evaluate dynamics in the thoracic aorta. Such information can also be combined with dedicated patient-specific computer-based simulations, to provide a further insight into the biomechanical aspects. In clinical practice, computational analysis might show the development of aortic disease, such as the aortic wall segments which experience higher stress in places where rupture and dissection may occur. In aortic dissections, the intimal tear is usually located at the level of the sino-tubular junction and/or at the origin of the left subclavian artery. Besides, computational models may potentially be used preoperatively to predict stent graft behavior, virtually testing the optimal stent graft sizing, deployment, and conformability, in order to provide the best endovascular treatment. The present study reviews the current literature regarding the use of computational tools for TEVAR biomechanics, highlighting their potential clinical applications.
Collapse
Affiliation(s)
- Guido H.W. van Bogerijen
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Milan, Italy
| | - Jip L. Tolenaar
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Milan, Italy
| | - Michele Conti
- Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Pavia, Italy
| | - Ferdinando Auricchio
- Department of Civil Engineering and Architecture, Structural Mechanics Division, University of Pavia, Pavia, Italy
| | - Francesco Secchi
- Department of Radiology, Policlinico San Donato IRCCS, University of Milan, Milan, Italy; and
| | - Francesco Sardanelli
- Department of Radiology, Policlinico San Donato IRCCS, University of Milan, Milan, Italy; and
| | - Frans L. Moll
- Department of Vascular Surgery, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Vincenzo Rampoldi
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Milan, Italy
| | - Santi Trimarchi
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Milan, Italy
| |
Collapse
|
30
|
Midulla M, Moreno R, Negre-Salvayre A, Nicoud F, Pruvo JP, Haulon S, Rousseau H. Impact of endografting on the thoracic aortic anatomy: comparative analysis of the aortic geometry before and after the endograft implantation. Cardiovasc Intervent Radiol 2013; 37:69-76. [PMID: 23483287 DOI: 10.1007/s00270-013-0601-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Accepted: 01/30/2013] [Indexed: 11/30/2022]
Abstract
PURPOSE Although the widespread acceptance of thoracic endovascular aortic repair (TEVAR) as a first-line treatment option for a multitude of thoracic aortic diseases, little is known about the consequences of the device implantation on the native aortic anatomy. We propose a comparative analysis of the pre- and postoperative geometry on a clinical series of patients and discuss the potential clinical implications METHODS CT pre- and postoperative acquisitions of 30 consecutive patients treated by TEVAR for different pathologies (20 thoracic aortic aneurysms, 6 false aneurysms, 3 penetrating ulcers, 1 traumatic rupture) were used to model the vascular geometry. Pre- and postoperative geometries were compared for each patient by pairing and matching the 3D models. An implantation site was identified, and focal differences were detected and described. RESULTS Segmentation of the data sets was successfully performed for all 30 subjects. Geometry differences between the pre- and postoperative meshes were depicted in 23 patients (76 %). Modifications at the upper implantation site were detected in 14 patients (47 %), and among them, the implantation site involved the arch (Z0-3) in 11 (78 %). CONCLUSION Modeling the vascular geometry on the basis of imaging data offers an effective tool to perform patient-specific analysis of the vascular geometry before and after the treatment. Future studies will evaluate the consequences of these changes on the aortic function.
Collapse
Affiliation(s)
- Marco Midulla
- Cardiovascular and Interventional Radiology, University Hospital of Lille, Lille, France,
| | | | | | | | | | | | | |
Collapse
|