1
|
Lisi C, Catapano F, Brilli F, Scialò V, Corghi E, Figliozzi S, Cozzi OF, Monti L, Stefanini GG, Francone M. CT imaging post-TAVI: Murphy's first law in action-preparing to recognize the unexpected. Insights Imaging 2024; 15:157. [PMID: 38900378 PMCID: PMC11189851 DOI: 10.1186/s13244-024-01729-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 05/16/2024] [Indexed: 06/21/2024] Open
Abstract
Transfemoral aortic valve implantation (TAVI) has been long considered the standard of therapy for high-risk patients with severe aortic-stenosis and is now effectively employed in place of surgical aortic valve replacement also in intermediate-risk patients. The potential lasting consequences of minor complications, which might have limited impact on elderly patients, could be more noteworthy in the longer term when occurring in younger individuals. That's why a greater focus on early diagnosis, correct management, and prevention of post-procedural complications is key to achieve satisfactory results. ECG-triggered multidetector computed tomography angiography (CTA) is the mainstay imaging modality for pre-procedural planning of TAVI and is also used for post-interventional early detection of both acute and long-term complications. CTA allows detailed morphological analysis of the valve and its movement throughout the entire cardiac cycle. Moreover, stent position, coronary artery branches, and integrity of the aortic root can be precisely evaluated. Imaging reliability implies the correct technical setting of the computed tomography scan, knowledge of valve type, normal post-interventional findings, and awareness of classic and life-threatening complications after a TAVI procedure. This educational review discusses the main post-procedural complications of TAVI with a specific imaging focus, trying to clearly describe the technical aspects of CTA Imaging in post-TAVI and its clinical applications and challenges, with a final focus on future perspectives and emerging technologies. CRITICAL RELEVANCE STATEMENT: This review undertakes an analysis of the role computed tomography angiography (CTA) plays in the assessment of post-TAVI complications. Highlighting the educational issues related to the topic, empowers radiologists to refine their clinical approach, contributing to enhanced patient care. KEY POINTS: Prompt recognition of TAVI complications, ranging from value issues to death, is crucial. Adherence to recommended scanning protocols, and the optimization of tailored protocols, is essential. CTA is central in the diagnosis of TAVI complications and functions as a gatekeeper to treatment.
Collapse
Affiliation(s)
- Costanza Lisi
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Federica Catapano
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy.
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy.
| | - Federica Brilli
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Vincenzo Scialò
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Eleonora Corghi
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Stefano Figliozzi
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Ottavia Francesca Cozzi
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Lorenzo Monti
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Giulio Giuseppe Stefanini
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| | - Marco Francone
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy
- IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy
| |
Collapse
|
2
|
Langenbach IL, Langenbach MC, Mayrhofer T, Foldyna B, Maintz D, Klein K, Wienemann H, Krug KB, Hellmich M, Adam M, Naehle CP. Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: a prospective clinical trial. Eur Radiol 2024; 34:4089-4099. [PMID: 37979008 PMCID: PMC11166752 DOI: 10.1007/s00330-023-10403-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/25/2023] [Accepted: 09/17/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION This study investigated the use of dual-energy spectral detector computed tomography (CT) and virtual monoenergetic imaging (VMI) reconstructions in pre-interventional transcatheter aortic valve replacement (TAVR) planning. We aimed to determine the minimum required contrast medium (CM) amount to maintain diagnostic CT imaging quality for TAVR planning. METHODS In this prospective clinical trial, TAVR candidates received a standardized dual-layer spectral detector CT protocol. The CM amount (Iohexol 350 mg iodine/mL, standardized flow rate 3 mL/s) was reduced systematically after 15 patients by 10 mL, starting at 60 mL (institutional standard). We evaluated standard, and 40- and 60-keV VMI reconstructions. For image quality, we measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and diameters in multiple vessel sections (i.e., aortic annulus: diameter, perimeter, area; aorta/arteries: minimal diameter). Mixed regression models (MRM), including interaction terms and clinical characteristics, were used for comparison. RESULTS Sixty consecutive patients (mean age, 79.4 ± 7.5 years; 28 females, 46.7%) were included. In pre-TAVR CT, the CM reduction to 40 mL is possible without affecting the image quality (MRM: SNR: -1.1, p = 0.726; CNR: 0.0, p = 0.999). VMI 40-keV reconstructions showed better results than standard reconstructions with significantly higher SNR (+ 6.04, p < 0.001). Reduction to 30 mL CM resulted in a significant loss of quality (MRM: SNR: -12.9, p < 0.001; CNR: -13.9, p < 0.001), regardless of the reconstruction. Across the reconstructions, we observed no differences in the metric evaluation (p > 0.914). CONCLUSION Among TAVR candidates undergoing pre-interventional CT at a dual-layer spectral detector system, applying 40 mL CM is sufficient to maintain diagnostic image quality. VMI 40-keV reconstructions improve the vessel attenuation and are recommended for evaluation. CLINICAL RELEVANCE STATEMENT Contrast medium reduction to 40 mL in pre-interventional transcatheter aortic valve replacement CT using dual-energy CT maintains image quality, while 40-keV virtual monoenergetic imaging reconstructions enhance vessel attenuation. These results offer valuable recommendations for interventional transcatheter aortic valve replacement evaluation and potentially improve nephroprotection in patients with compromised renal function. KEY POINTS • Patients undergoing transcatheter aortic valve replacement (TAVR), requiring pre-interventional CT, are often multimorbid with impaired renal function. • Using a spectral detector dual-layer CT, contrast medium reduction to 40 mL is feasible, maintaining diagnostic image quality. • The additional application of virtual monoenergetic image reconstructions with 40 keV improves vessel attenuation significantly in clinical practice.
Collapse
Affiliation(s)
- Isabel L Langenbach
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA.
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
| | - Marcel C Langenbach
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Thomas Mayrhofer
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
- School of Business Studies, Stralsund University of Applied Sciences, Stralsund, Germany
| | - Borek Foldyna
- Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Konstantin Klein
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Hendrik Wienemann
- Clinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - Kathrin B Krug
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Martin Hellmich
- Institute of Medical Statistics and Computational Biology, Medical Faculty, University of Cologne, Cologne, Germany
| | - Matti Adam
- Clinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | | |
Collapse
|
3
|
Kolck J, Trippel TD, Philipp K, Gehle P, Geisel D, Beetz NL. Updated 2022 ACC/AHA Guideline Improves Concordance Between TTE and CT in Monitoring Marfan Snydrome and Related Disorders, but Relevant Measurement Differences Remain Frequent. Glob Heart 2024; 23:28. [PMID: 38737456 PMCID: PMC11086607 DOI: 10.5334/gh.1322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 04/16/2024] [Indexed: 05/14/2024] Open
Abstract
Background Patients diagnosed with Marfan syndrome or a related syndrome require frequent aorta monitoring using imaging techniques like transthoracic echocardiography (TTE) and computed tomography (CT). Accurate aortic measurement is crucial, as even slight enlargement (>2 mm) often necessitates surgical intervention. The 2022 ACC/AHA guideline for Aortic Disease Diagnosis and Management includes updated imaging recommendations. We aimed to compare these with the 2010 guideline. Methods This retrospective study involved 137 patients with Marfan syndrome or a related disorder, undergoing TTE and ECG-triggered CT. Aortic diameter measurements were taken based on the old 2010 guideline (TTE: inner edge to inner edge, CT: external diameter) and the new 2022 guideline (TTE: leading edge to leading edge, CT: internal diameter). Bland-Altman plots compared measurement differences. Results Using the 2022 guideline significantly reduced differences outside the clinical agreement limit from 49% to 26% for the aortic sinus and from 41% to 29% for the ascending aorta. Mean differences were -0.30 mm for the aortic sinus and +1.12 mm for the ascending aorta using the 2022 guideline, compared to -2.66 mm and +1.21 mm using the 2010 guideline. Conclusion This study demonstrates for the first time that the 2022 ACC/AHA guideline improves concordance between ECG-triggered CT and TTE measurements in Marfan syndrome patients, crucial for preventing life-threatening aortic complications. However, the frequency of differences >2 mm remains high. Clinical Relevance/Application Accurate aortic diameter measurement is vital for patients at risk of fatal aortic complications. While the 2022 guideline enhances concordance between imaging modalities, frequent differences >2 mm persist, potentially impacting decisions on aortic repair. The risk of repeat radiation exposure from ECG-triggered CT, considered the 'gold standard', continues to be justified.
Collapse
Affiliation(s)
- Johannes Kolck
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin, Germany
- BIH (Berlin Institute of Health), Berlin, Germany
| | - Tobias Daniel Trippel
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Internal Medicine –Cardiology, Charitéplatz 1, 10117 Berlin, Germany
- Deutsches Herzzentrum der Charité, Department of Cardiology, Angiology and Intensive Care Medicine, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Karla Philipp
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Internal Medicine –Cardiology, Charitéplatz 1, 10117 Berlin, Germany
| | - Petra Gehle
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Internal Medicine –Cardiology, Charitéplatz 1, 10117 Berlin, Germany
- Deutsches Herzzentrum der Charité, Department of Cardiology, Angiology and Intensive Care Medicine, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Dominik Geisel
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Nick Lasse Beetz
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin, Germany
- BIH (Berlin Institute of Health), Berlin, Germany
- DZHK (German Center for Cardiovascular Research), partner site Berlin, Germany
| |
Collapse
|
4
|
Gallo GS, Caruso C, Iannazzo E, Cannataci C, Gerasia R, Tafaro C, Gentile G, Mamone G, Caruso S, Marrone G, Gandolfo C, Miraglia R. Feasibility of Ultra-Low Volume Contrast-Saline Mixture Injection With Dual-Flow Technique in a Pre-TAVI Computed Tomography Angiography. Heart Lung Circ 2023; 32:525-534. [PMID: 36804708 DOI: 10.1016/j.hlc.2022.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 12/10/2022] [Accepted: 12/16/2022] [Indexed: 02/19/2023]
Abstract
BACKGROUND To explore the feasibility and image quality of ultra-low volume contrast-saline mixture injection with dual-flow injection technique in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI). METHODS Forty (40) TAVI candidates underwent investigation with CTA using a third-generation dual-source CT scanner between September and November 2020. Different volumes of a monophasic contrast-saline mixture at an 80:20 ratio were administered at an infusion rate of 3 mL/s in 20 patients (group A). The injected volume was based on patient body mass index (BMI): 50 mL if BMI <29 kg/m2 and 63 mL if BMI >29 kg/m2. The other 20 patients (group B)-the control cases-received a total of 65 mL of contrast medium (CM), in multiphasic injections at different flow rates, followed by 10 mL of saline. The images that were obtained were prospectively evaluated for image quality, vessel attenuation (HU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and estimated radiation dose. RESULTS Image quality of the aortic root and ilio-femoral vessels was diagnostic in all patients. Vascular attenuation was >200 HU and CNR >3 at any vessel level. CONCLUSIONS Data from this study suggest that a monophasic ultra-low volume contrast-saline mixture injection with a dual-flow technique can provide clear visualisation of the aortic root and ilio-femoral vessels in pre-TAVI CTA, which is comparable with a standard multiphasic volume injection protocol.
Collapse
Affiliation(s)
- Giuseppe S Gallo
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy.
| | - Calogero Caruso
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Erica Iannazzo
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | | | - Roberta Gerasia
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Corrado Tafaro
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Giovanni Gentile
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Giuseppe Mamone
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Settimo Caruso
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Gianluca Marrone
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Caterina Gandolfo
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| | - Roberto Miraglia
- Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy
| |
Collapse
|
5
|
Lacy SC, Benjamin MM, Osman M, Syed MA, Kinno M. Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review. J Cardiovasc Imaging 2023; 31:108-115. [PMID: 37096677 PMCID: PMC10133812 DOI: 10.4250/jcvi.2022.0108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 12/23/2022] [Accepted: 01/03/2023] [Indexed: 02/22/2023] Open
Abstract
BACKGROUND Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.
Collapse
Affiliation(s)
- Spencer C. Lacy
- Department of Internal Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Mina M. Benjamin
- Division of Cardiovascular Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Mohammed Osman
- Knight & Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Mushabbar A. Syed
- Division of Cardiovascular Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Menhel Kinno
- Division of Cardiovascular Medicine, Loyola University Medical Center, Maywood, IL, USA
| |
Collapse
|
6
|
El Garhy M, Owais T, Lauten P. Aortic valve calcium volume as measured by native versus contrast-enhanced computer tomography and the implications for the diagnosis of severe aortic stenosis in TAVR patients with low-gradient aortic stenosis. Egypt Heart J 2022; 74:71. [PMID: 36178641 PMCID: PMC9525474 DOI: 10.1186/s43044-022-00311-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Accepted: 09/22/2022] [Indexed: 11/18/2022] Open
Abstract
Background Most of TAVR centers evaluate the calcium score in contrast-enhanced (ce) CT. We compared in this study between different methodologies to measure calcium score. We studied also the difference between patients with low-gradient (LG) and high-gradient (HG) severe aortic stenosis (AS) as regard the burden of aortic valve calcium (AVC).
Results We measured the calcium volume and score using Agatston methodology in non-contrast (nc) CT and with modified and fixed 850 Hounsfield unit (HU) thresholds in ce CT. The calcium score and volume in ceCT using even with modified thresholds is significantly lower than the assessed score and volume in ncCT. The median (IQR) of calcium score in nc CT and in cc CT were 1288 AU (750–1815) versus 947 HU (384–2202). The median (IQR) of calcium volume in nc CT and in cc CT with modified thresholds were 701 mm3 (239–1632) versus 197 mm3 (139–532). Agatston score and calcium volume were lower in patients with LG AS than HG AS; 2069 AU (899–2477) versus 928AU (572–1284) and 1537 mm3 (644–1860) versus 286 mm3 (160–700), respectively. Only 20% of patients with LGAS had Agatston score higher than the previously supposed AVC score threshold for the diagnosis of severe AS (> 2000AU in men and > 1200 in women).
Conclusions The diagnosis of severe LGAS should not depend on a single parameter as calcium score. In these patients, calcium score should be measured in nc CT and not in ce CT.
Collapse
|
7
|
Beetz NL, Trippel TD, Philipp K, Maier C, Walter-Rittel T, Shnayien S, Gehle P. Discrepancy of echocardiography and computed tomography in initial assessment and 2-year follow-up for monitoring Marfan syndrome and related disorders. Sci Rep 2022; 12:15333. [PMID: 36097197 PMCID: PMC9468173 DOI: 10.1038/s41598-022-19662-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 09/01/2022] [Indexed: 11/26/2022] Open
Abstract
Patients with Marfan syndrome and related disorders are at risk for aortic dissection and aortic rupture and therefore require appropriate monitoring. Computed tomography (CT) and transthoracic echocardiography (TTE) are routinely used for initial diagnosis and follow-up. The purpose of this study is to compare whole-heart CT and TTE aortic measurement for initial work-up, 2-year follow-up, and detection of progressive aortic enlargement. This retrospective study included 95 patients diagnosed with Marfan syndrome or a related disorder. All patients underwent initial work-up including aortic diameter measurement using both electrocardiography-triggered whole-heart CT and TTE. Forty-two of these patients did not undergo aortic repair after initial work-up and were monitored by follow-up imaging within 2 years. Differences between the two methods for measuring aortic diameters were compared using Bland-Altman plots. The acceptable clinical limit of agreement (acLOA) for initial work-up, follow-up, and progression within 2 years was predefined as < ± 2 mm. Bland-Altman analysis revealed a small bias of 0.2 mm with wide limits of agreement (LOA) from + 6.3 to - 5.9 mm for the aortic sinus and a relevant bias of - 1.6 mm with wide LOA from + 5.6 to - 8.9 mm for the ascending aorta. Follow-up imaging yielded a small bias of 0.5 mm with a wide LOA from + 6.7 to - 5.8 mm for the aortic sinus and a relevant bias of 1.1 mm with wide LOA from + 8.1 to - 10.2 mm for the ascending aorta. Progressive aortic enlargement at follow-up was detected in 57% of patients using CT and 40% of patients using TTE. Measurement differences outside the acLOA were most frequently observed for the ascending aorta. Whole-heart CT and TTE measurements show good correlation, but the frequency of measurement differences outside the acLOA is high. TTE systematically overestimates aortic diameters. Therefore, whole-heart CT may be preferred for aortic monitoring of patients with Marfan syndrome and related disorders. TTE remains an indispensable imaging tool that provides additional information not available with CT.
Collapse
Affiliation(s)
- Nick Lasse Beetz
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
- BIH Biomedical Innovation Academy, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany.
| | - Tobias Daniel Trippel
- Department of Internal Medicine - Cardiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Karla Philipp
- Department of Internal Medicine - Cardiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Christoph Maier
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Thula Walter-Rittel
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Seyd Shnayien
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Petra Gehle
- Department of Internal Medicine - Cardiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| |
Collapse
|
8
|
Martin SS, Kolaneci J, Czwikla R, Booz C, Gruenewald LD, Albrecht MH, Thompson ZM, Lenga L, Yel I, Vogl TJ, Wichmann JL, Koch V. Dual-Energy CT for the Detection of Portal Vein Thrombosis: Improved Diagnostic Performance Using Virtual Monoenergetic Reconstructions. Diagnostics (Basel) 2022; 12:diagnostics12071682. [PMID: 35885585 PMCID: PMC9317258 DOI: 10.3390/diagnostics12071682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 06/26/2022] [Accepted: 07/07/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.
Collapse
Affiliation(s)
- Simon S. Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC 29425, USA;
- Correspondence: ; Tel.: +49-(0)69-6301-80414; Fax: +49-(0)69-6301-7288
| | - Jetlir Kolaneci
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Rouben Czwikla
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Leon D. Gruenewald
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Moritz H. Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Zachary M. Thompson
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC 29425, USA;
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Thomas J. Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Julian L. Wichmann
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| | - Vitali Koch
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany; (J.K.); (R.C.); (C.B.); (L.D.G.); (M.H.A.); (L.L.); (I.Y.); (T.J.V.); (J.L.W.); (V.K.)
| |
Collapse
|
9
|
Nappi F, Avtaar Singh SS, Nappi P, Fiore A. Biomechanics of Transcatheter Aortic Valve Implant. Bioengineering (Basel) 2022; 9:bioengineering9070299. [PMID: 35877350 PMCID: PMC9312295 DOI: 10.3390/bioengineering9070299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/28/2022] [Accepted: 06/29/2022] [Indexed: 11/16/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has grown exponentially within the cardiology and cardiac surgical spheres. It has now become a routine approach for treating aortic stenosis. Several concerns have been raised about TAVI in comparison to conventional surgical aortic valve replacement (SAVR). The primary concerns regard the longevity of the valves. Several factors have been identified which may predict poor outcomes following TAVI. To this end, the lesser-used finite element analysis (FEA) was used to quantify the properties of calcifications which affect TAVI valves. This method can also be used in conjunction with other integrated software to ascertain the functionality of these valves. Other imaging modalities such as multi-detector row computed tomography (MDCT) are now widely available, which can accurately size aortic valve annuli. This may help reduce the incidence of paravalvular leaks and regurgitation which may necessitate further intervention. Structural valve degeneration (SVD) remains a key factor, with varying results from current studies. The true incidence of SVD in TAVI compared to SAVR remains unclear due to the lack of long-term data. It is now widely accepted that both are part of the armamentarium and are not mutually exclusive. Decision making in terms of appropriate interventions should be undertaken via shared decision making involving heart teams.
Collapse
Affiliation(s)
- Francesco Nappi
- Department of Cardiac Surgery, Centre Cardiologique du Nord, 93200 Saint-Denis, France
- Correspondence: ; Tel.: +33-149334104; Fax: +33-149334119
| | | | - Pierluigi Nappi
- Department of Clinical and Experimental Medicine, University of Messina, 98122 Messina, Italy;
| | - Antonio Fiore
- Department of Cardiac Surgery, Hôpitaux Universitaires Henri Mondor, Assistance Publique-Hôpitaux de Paris, 94000 Creteil, France;
| |
Collapse
|
10
|
Prospective Study of Low-Radiation and Low-Iodine Dose Aortic CT Angiography in Obese and Non-Obese Patients: Image Quality and Impact of Patient Characteristics. Diagnostics (Basel) 2022; 12:diagnostics12030675. [PMID: 35328228 PMCID: PMC8947155 DOI: 10.3390/diagnostics12030675] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/02/2022] [Accepted: 03/08/2022] [Indexed: 11/16/2022] Open
Abstract
The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic CTA between November 2017 and August 2020 without symptoms of high-grade heart failure. A BMI-adapted protocol was used: Group A/Group B, BMI < 30/≥ 30 kg/m2, tube potential 80/100 kVp, total iodine dose 14.5/17.4 g. Intraindividual comparison with the institutional clinical routine aortic CTA protocol was performed. The final study cohort comprised 161 patients (mean 71.1 ± 9.4 years, 32 women), thereof 126 patients in Group A (mean BMI 25.4 ± 2.8 kg/m2) and 35 patients in Group B (34.0 ± 3.4 kg/m2). Mean attenuation over five aortoiliac measurement positions for Group A/B was 354.9 ± 78.2/262.1 ± 73.0 HU. Mean effective dose for Group A/B was 3.05 ± 0.46/6.02 ± 1.14 mSv. Intraindividual comparison in 50 patients demonstrated effective dose savings for Group A/B of 34.4 ± 14.5/25.4 ± 14.1% (both p < 0.001), and iodine dose savings for Group A/B of 54/44.8%. Regression analysis showed that female sex and increasing age were independently associated with higher vascular attenuation. In conclusion, BMI-adapted, low-radiation and low-iodine dose CTA of the thoracoabdominal aorta delivers diagnostic image quality in non-obese and obese patients without symptoms of high-grade heart failure, with superior image quality in females and the elderly.
Collapse
|
11
|
Combined Coronary CT Angiography and Evaluation of Access Vessels for TAVR Patients in Free-Breathing with Single Contrast Medium Injection Using a 16-cm-Wide Detector CT. Acad Radiol 2021; 28:1662-1668. [PMID: 32859475 DOI: 10.1016/j.acra.2020.08.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 08/06/2020] [Accepted: 08/08/2020] [Indexed: 02/05/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate the feasibility of combining coronary computed tomography (CT) angiography (CCTA) and CTA to evaluate access vessels for transcatheter aortic valve replacement (TAVR) patients in free-breathing and with single contrast medium injection using a 16-cm-wide detector CT. MATERIALS AND METHODS One hundred and twenty-one consecutive patients (73.33 ± 6.43 years) referred for TAVR underwent a serious CT scans in free-breathing after one contrast injection: ECG-triggered one-heartbeat axial CCTA, followed by non-ECG-gated neck, thoracic, and abdominal CTA. Patient weight-dependent contrast dose volume at 1.0 mL/kg was used. CT attenuation values of the coronary, neck, aortic, iliac, and femoral arteries were measured and their image quality was evaluated with a 4-point score method. Stenosis (≥50%) in CCTA was evaluated using invasive coronary angiography result as a reference standard. Radiation and contrast doses were assessed. RESULTS The total dose-length-product for the entire examination was 411.4 ± 91.2 mGy.cm, and the total contrast dose was 57.3 ± 9.9 mL. There were adequate attenuations (>400 HU) in all arteries, and the peripheral access vessels and aortic annulus were evaluable in all patients. In neck CTA, 5 patients had vascular tortuosity, 6 patients had aberrant arteries and there were 212 plaques and 13 severe stenoses among the patients. In CCTA, on the per-segment, per-vessel, and per-patient analysis, CCTA showed a sensitivity and negative predictive value of (95% and 99%), (95% and 99%), and (96% and 98%), respectively, for the entire patient cohort, and (92% and 98%), (92% and 98%), and (88% and 93%), respectively, for patients with atrial fibrillation or heart rate higher than 75 beats. CONCLUSION It is feasible to perform a combined CCTA and CTA for evaluating access vessels for TAVR patients in free-breathing with single contrast injection. This approach generates acceptable image quality for all vessels and a high negative predictive value in excluding coronary artery disease with relatively low radiation and contrast doses.
Collapse
|
12
|
Low kV Computed Tomography of Parenchymal Abdominal Organs-A Systematic Animal Study of Different Contrast Media Injection Protocols. Tomography 2021; 7:815-828. [PMID: 34941641 PMCID: PMC8705800 DOI: 10.3390/tomography7040069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/17/2021] [Accepted: 11/23/2021] [Indexed: 01/14/2023] Open
Abstract
Objectives: To evaluate multiphase low kV computed tomography (CT) imaging of the abdomen with reduced contrast media (CM) dose using different injection protocols. Methods: Two injection protocols were evaluated for use with low kV (80 kV) multiphase abdominal imaging in comparison to the standard procedure acquired at 120 kV (500 mgI/kg; 5 mL/s). This evaluation was conducted in a highly standardized animal study (5 Goettingen minipigs). The low kV protocols consisted of (a) a single-flow (SF) injection with 40% reduced CM dose and injection rate (300 mgI/kg; 3 mL/s) and (b) a DualFlow (DF) injection protocol consisting of 60%/40% contrast to saline ratio administered at 5 mL/s. Dynamic CT was first performed within representative liver regions to determine optimal contrast phases, followed by evaluation of the three protocols in multiphase abdominal CT imaging. The evaluation criteria included contrast enhancement (CE) of abdominal organs and vasculature. Results: The 80 kV DF injection protocol showed similar CE of the abdominal parenchymatous organs and vessels to the 120 kV reference and the 80 kV SF protocol. Hepatic parenchyma showed comparable CT values for all contrast phases. In particular, in the portal venous parenchymal phase, the 80 kV DF protocol demonstrated higher hepatic parenchymal enhancement; however, results were statistically non-significant. Similarly, CE of the kidney, pancreas, and abdominal arterial/venous vessels showed no significant differences between injection protocols. Conclusions: Adapted SF and DF injection protocols with reduced IDR/iodine load offer the potential to calibrate optimal CM doses to the tube voltage in abdominal multiphase low kV CT imaging. The data suggest that the DF approach allows the use of predefined injection protocols and adaption of the contrast to saline ratio to an individualized kV setting and yields the potential for patient-individualized CM adaption.
Collapse
|
13
|
Salgado R, El Addouli H, Budde RPJ. Transcatheter Aortic Valve Implantation: The Evolving Role of the Radiologist in 2021. ROFO-FORTSCHR RONTG 2021; 193:1411-1425. [PMID: 34814198 DOI: 10.1055/a-1645-1873] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) has gained worldwide acceptance and implementation as an alternative therapeutic option in patients with severe aortic valve stenosis unable to safely undergo surgical aortic valve replacement. This transformative technique places the radiologist in a key position in the pre-procedural assessment of potential candidates for this technique, delivering key anatomical information necessary for patient eligibility and procedural safety. Recent trials also provide encouraging results to potentially extend the indication to patients with safer risk profiles. METHOD The review is based on a PubMed literature search using the search terms "transcatheter heart valve", "TAVI", "TAVR", "CT", "imaging", "MR" over a period from 2010-2020, combined with personal comments based on the author's experience. RESULTS AND CONCLUSION CT plays a prominent role in the pre-procedural workup, delivering as a true 3D imaging modality optimal visualization of the complex anatomy of the aortic root with simultaneous evaluation of the patency of the different access routes. As such, the contribution of CT is key for the determination of patient eligibility and procedural safety. This input is supplementary to the contributions of other imaging modalities and forms an important element in the discussions of the Heart Valve Team. Knowledge of the procedure and its characteristics is necessary in order to provide a comprehensive and complete report. While the role of CT in the pre-procedural evaluation is well established, the contribution of CT and MR and the clinical significance of their findings in the routine follow-up after the intervention are less clear and currently the subject of intense investigation. Important issues remain, including the occurrence and significance of subclinical leaflet thrombosis, prosthetic heart valve endocarditis, and long-term structural valve degeneration. KEY POINTS · CT plays a crucial role in evaluating transcatheter heart valve candidates. · Evaluation must include the dimensions of the aortic root and access paths. · The exact post-procedural role of CT and MRI has not yet been determined.. CITATION FORMAT · Salgado R, El Addouli H, Budde RP. Transcatheter Aortic Valve Implantation: The Evolving Role of the Radiologist in 2021. Fortschr Röntgenstr 2021; 193: 1411 - 1425.
Collapse
Affiliation(s)
- Rodrigo Salgado
- Radiology, UZA, Edegem, Belgium.,Radiology, Holy Heart Hospital Lier, Belgium
| | | | | |
Collapse
|
14
|
Feasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement. J Comput Assist Tomogr 2021; 46:50-55. [DOI: 10.1097/rct.0000000000001238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
15
|
Sandner SE, Nolz R, Loewe C, Gregorich M, Heinze G, Andreas M, Kolh P, Zimpfer D, Laufer G. Routine preoperative aortic computed tomography angiography is associated with reduced risk of stroke in coronary artery bypass grafting: a propensity-matched analysis. Eur J Cardiothorac Surg 2021; 57:684-690. [PMID: 31504374 DOI: 10.1093/ejcts/ezz237] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 07/22/2019] [Accepted: 07/31/2019] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVES The aim of this study was to determine stroke rates in patients who did or did not undergo routine computed tomography angiography (CTA) aortic imaging before isolated coronary artery bypass grafting (CABG). METHODS We conducted a retrospective analysis of a prospectively maintained single-centre registry. Between 2009 and 2016, a total of 2320 consecutive patients who underwent isolated CABG at our institution were identified. Propensity score matching was used to create a paired cohort of patients with similar baseline characteristics who did (CTA cohort) or did not (non-CTA cohort) undergo preoperative aortic CTA. The primary end point of the analysis was in-hospital stroke. RESULTS In 435 propensity score-matched pairs, stroke occurred in 4 patients (0.92%) in the CTA cohort and in 14 patients (3.22%) in the non-CTA cohort (P = 0.017). Routine preoperative aortic CTA was associated with a significantly reduced risk of in-hospital stroke [relative risk 0.29, 95% confidence interval (CI) 0.09-0.86; P = 0.026; absolute risk reduction 2.3%, 95% CI 0.4-4.2; P = 0.017; number needed to treat = 44, 95% CI 24-242]. CONCLUSIONS A preoperative screening for atheromatous aortic disease using CTA is associated with reduced risk of stroke after CABG. The routine use of preoperative aortic CTA could be applied so that surgical manipulation of the ascending aorta can be selectively reduced or avoided in patients with atheromatous aortic disease.
Collapse
Affiliation(s)
- Sigrid E Sandner
- Division of Cardiac Surgery, Department of Surgery, Medical University Vienna, Vienna, Austria
| | - Richard Nolz
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University Vienna, Vienna, Austria
| | - Christian Loewe
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University Vienna, Vienna, Austria
| | - Mariella Gregorich
- Center for Medical Statistics, Informatics and Intelligent Systems, Clinical Biometrics Section, Medical University Vienna, Vienna, Austria
| | - Georg Heinze
- Center for Medical Statistics, Informatics and Intelligent Systems, Clinical Biometrics Section, Medical University Vienna, Vienna, Austria
| | - Martin Andreas
- Division of Cardiac Surgery, Department of Surgery, Medical University Vienna, Vienna, Austria
| | - Philippe Kolh
- Department of Biomedical and Preclinical Sciences, University of Liege, Liege, Belgium
| | - Daniel Zimpfer
- Division of Cardiac Surgery, Department of Surgery, Medical University Vienna, Vienna, Austria
| | - Guenther Laufer
- Division of Cardiac Surgery, Department of Surgery, Medical University Vienna, Vienna, Austria
| |
Collapse
|
16
|
Three-Dimensional Transesophageal Echocardiography as an Alternative to Multidetector Computed Tomography in Aortic Annular Diameter Measurements for Transcatheter Aortic Valve Implantation. BIOLOGY 2021; 10:biology10020132. [PMID: 33567521 PMCID: PMC7916087 DOI: 10.3390/biology10020132] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 02/02/2021] [Indexed: 02/07/2023]
Abstract
Simple Summary Patients who have multiple associated comorbidities and need to change the aortic valve may have a contraindication to open-heart surgery, the alternative being transcatheter aortic valve implantation, which requires very precise measurements of the aortic annulus to determine the dimensions of the prostheses. Ultrasonographic imaging techniques, such as transesophageal echocardiography, are constantly evolving. The aim of our study was to compare the three-dimensional transesophageal echocardiography and multi-detector computer tomography methods, with the former being an alternative for patients who cannot undergo computer tomography because of a major contraindication. We have demonstrated that there were small differences between aortic annular measurements using multi-detector computer tomography (2.25 ± 0.19 cm) and three-dimensional transesophageal echocardiography (2.25 ± 0.15 cm). Thus, three-dimensional transesophageal echocardiography can be the solution for aortic annular measurements used to select the correct prosthesis for the transcatheter aortic valve implantation procedure in patients who cannot undergo computer tomography. Abstract Background and objectives: Transcatheter aortic valve implantation (TAVI) is a therapeutic choice for high surgical risk patients, serving as an alternative to open-heart surgery. Correct measurement of the aortic annulus, which leads to the selection of a suitable prosthesis and accurate outcome prediction, is essential for the success of TAVI. The objective of this study is to evaluate the accuracy of novel imaging te chniques in measuring the aortic annulus by comparing multi-detector computer tomography (MDCT) and three-dimensional transesophageal echocardiography (3D TEE) for the selection of the optimal prosthesis. Materials and Methods: Measurements of the aortic annulus have been performed on 25 patients using MDCT and TEE, and the correlation and agreement levels between the two measuring techniques were analyzed. MDCT measurements were used for the sizing of the prostheses. Results: MDCT and TEE measurements of aortic annular diameters were significantly correlated, with a mean difference of 0.001 cm. Conclusions: 3D TEE measurements have been in good agreement with MDCT and, therefore, 3D TEE can be used as an alternative in cases where MDCT is contraindicated or not available.
Collapse
|
17
|
Hassanein M, Abdelfattah OM, Saad AM, Isogai T, Gad MM, Ahuja KR, Ahmed T, Shekhar S, Fatica R, Poggio E, Kapadia SR. Short-Term Outcomes of Transcatheter Aortic Valve Replacement in Kidney Transplant Recipients: A Nationwide Representative Study. STRUCTURAL HEART 2021. [DOI: 10.1080/24748706.2020.1845918] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
18
|
Musumeci G, Colopi M. Renal function and outcomes in TAVR patients: Complexity in real world. Catheter Cardiovasc Interv 2020; 96:1509-1510. [PMID: 33245193 DOI: 10.1002/ccd.29410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 11/18/2020] [Indexed: 11/06/2022]
Abstract
Renal dysfunction is a relevant medical issue for patients undergoing TAVR. Chronic kidney disease and postprocedural acute kidney injury are independent predictors of worse outcome after TAVR procedure. Meticulous preprocedural planning and multidisciplinary heart-team management could mitigate renal damage.
Collapse
Affiliation(s)
- Giuseppe Musumeci
- Division of Cardiology, Azienda Ospedaliera Ordine Mauriziano di Torino, Turin, Italy
| | - Marzia Colopi
- Division of Cardiology, Azienda Ospedaliera Ordine Mauriziano di Torino, Turin, Italy
| |
Collapse
|
19
|
Coronary artery bypass grafting and perioperative stroke: imaging of atherosclerotic plaques in the ascending aorta with ungated high-pitch CT-angiography. Sci Rep 2020; 10:13909. [PMID: 32807858 PMCID: PMC7431556 DOI: 10.1038/s41598-020-70830-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 08/03/2020] [Indexed: 11/09/2022] Open
Abstract
Perioperative stroke is a devastating complication after coronary artery bypass graft (CABG) surgery, with atherosclerosis of the ascending aorta as important risk factor. During surgical manipulation, detachment of plaques can lead to consecutive embolization into brain-supplying arteries. High-pitch computed tomography angiography (HP-CTA) represents a non-invasive imaging modality, which provides the opportunity for comprehensive imaging of the ascending aorta, including plaque detection and advanced characterization. In our present retrospective study on 719 individuals, who had undergone HP-CTA within 6 months prior to CABG, atherosclerotic disease of the ascending aorta was evaluated with respect to perioperative stroke rates. For image analysis, the ascending aorta was divided into a proximal and distal part, consisting of four segments, and evaluated for presence and distribution of calcified and mixed plaques. All patients with perioperative stroke presented with atherosclerotic disease of the ascending aorta. The stroke rate was significantly associated with the presence and extent of atherosclerotic disease. Patients burdened with mixed plaques presented with significantly higher perioperative stroke rates. This study demonstrates that HP-CTA allows accurate evaluation of plaque extent and composition in the ascending aorta, and therefore may improve risk stratification of stroke prior to CABG.
Collapse
|
20
|
Maffeo D, Bettari L, Latib A, Maiandi C, Villa E, Messina A, Saccocci M, Arneri A, Cuccia C, Troise G. Transfemoral transcatheter aortic valve replacement without contrast medium using the Medtronic CoreValve system: a single center experience. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:489-495. [DOI: 10.23736/s0021-9509.20.11083-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
Shnayien S, Bressem KK, Beetz NL, Asbach P, Hamm B, Niehues SM. Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience. ROFO-FORTSCHR RONTG 2020; 192:1174-1182. [PMID: 32299112 DOI: 10.1055/a-1150-7646] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
PURPOSE To retrospectively investigate the effectiveness of a novel 3-phase protocol for computed tomography (CT) before transcatheter aortic valve implantation/transcatheter aortic valve replacement (TAVI/TAVR) in terms of radiation dose and image quality. MATERIALS AND METHODS A total of 107 nonrandomized patients (81 ± 7.4 years) scheduled for TAVI/TAVR underwent preprocedural CT on an 80-row CT scanner. 55 patients underwent a combined ECG-synchronized spiral scan of the chest and non-ECG-synchronized spiral scan of the abdomen/pelvis as recommended by the Society of Cardiovascular Computed Tomography (SCCT). 52 patients underwent an updated 3-phase variable helical pitch (vHP3) protocol combining a non-ECG-synchronized spiral scan of the upper thoracic aperture, followed by a prospective ECG-synchronized spiral scan of the heart, and a non-ECG-synchronized abdominal/pelvic spiral scan. The radiation dose was determined from an automatically generated protocol based on the CT dose index (CTDI). Objective image quality in terms of vessel attenuation and image noise was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was evaluated using a 4-point scale and compared for interrater agreement using Cohen's weighted kappa coefficient (κw). All data were compared and statistically analyzed. RESULTS Use of the novel 3-phase vHP3 protocol reduced the dose-length product (DLP) from 1256.58 ± 619.05 mGy*cm to 790.90 ± 238.15 mGy*cm, reducing the effective dose (E) from 21.36 ± 10.52 mSv to 13.44 ± 4.05 mSv and size-specific dose estimates (SSDE) from 20.85 ± 7.29 mGy to 13.84 ± 2.94 mGy (p < 0.001). There were no significant differences in objective and subjective image quality between the two protocols and between the two readers. CONCLUSION The novel 3-phase vHP3 protocol significantly reduces the radiation dose of preprocedural TAVI/TAVR CT without a loss of image quality. KEY POINTS · The use of a novel 3-phase protocol for preprocedural TAVI/TAVR CT reduces radiation dose by 37 % compared to a combined ECG-synchronized and non-ECG-synchronized spiral CT protocol.. · Objective image quality remains unaffected as image noise, SNR, and CNR did not differ significantly between the two protocols. The average attenuation of the aortic root and abdominal aorta exceeded 450 HU in both protocols.. · The average subjective image quality ratings were good to excellent for both protocols with almost perfect to substantial interrater agreement.. CITATION FORMAT · Shnayien S, Bressem KK, Beetz NL et al. Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience. Fortschr Röntgenstr 2020; 192: 1174 - 1182.
Collapse
Affiliation(s)
- Seyd Shnayien
- Radiology, Charité-Universitätsmedizin Berlin, Germany
| | | | | | | | - Bernd Hamm
- Radiology, Charité-Universitätsmedizin Berlin, Germany
| | | |
Collapse
|
22
|
Suchá D, Kino A, Bogart K, Molvin L, Cheng X, Fearon W, Fischbein M, Fleischmann D. Effect of low contrast medium-dose CTA on device sizing and access vessel assessment for TAVR. Eur J Radiol 2020; 124:108826. [DOI: 10.1016/j.ejrad.2020.108826] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 12/09/2019] [Accepted: 01/06/2020] [Indexed: 01/22/2023]
|
23
|
Third generation dual source CT with ultra-high pitch protocol for TAVI planning and coronary tree assessment: feasibility, image quality and diagnostic performance. Eur J Radiol 2020; 122:108749. [DOI: 10.1016/j.ejrad.2019.108749] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2019] [Revised: 11/07/2019] [Accepted: 11/12/2019] [Indexed: 01/14/2023]
|
24
|
Ippolito D, Riva L, Talei Franzesi C, De Vito A, Cangiotti C, Crespi A, Corso R, Sironi S. Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol. J Comput Assist Tomogr 2020; 44:13-19. [PMID: 31939876 DOI: 10.1097/rct.0000000000000965] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol. METHODS Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups. RESULTS In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001). CONCLUSION Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.
Collapse
Affiliation(s)
| | | | | | | | | | - Andrea Crespi
- Department of Medical Physics, "San Gerardo" Hospital, Monza
| | - Rocco Corso
- From the Department of Diagnostic Radiology, "San Gerardo" Hospital
| | | |
Collapse
|
25
|
Yucel-Finn A, Nicol E, Leipsic JA, Weir-McCall JR. CT in planning transcatheter aortic valve implantation procedures and risk assessment. Clin Radiol 2019; 76:73.e1-73.e19. [PMID: 31883615 DOI: 10.1016/j.crad.2019.11.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 11/13/2019] [Indexed: 12/31/2022]
Abstract
For surgical aortic valve replacement, the Society of Thoracic Surgeons score (STSS) is the reference standard for the prediction of operative risk. In transcatheter aortic valve implantation (TAVI) though, where the procedure itself is minimally invasive, the traditional risk assessment is supplemented by CTA. Through a consistent approach to the acquisition of high-quality images and the standardised reporting of annular measurements and adverse root and vascular features, patients at risk of complications can be identified. In turn, this may allow for a personalised procedural approach and treatment strategies devised to potentially reduce or mitigate this risk. This article provides a systematic and standardised approach to pre-procedural work-up with computed tomography angiography (CTA) and explores the current state of evidence and future areas of development in this rapidly developing field.
Collapse
Affiliation(s)
| | - E Nicol
- Royal Brompton Hospital, London, UK
| | - J A Leipsic
- St Paul's Hospital, Vancouver, British Columbia, Canada
| | - J R Weir-McCall
- Royal Papworth Hospital, Cambridge, UK; University of Cambridge School of Clinical Medicine, Cambridge, UK.
| |
Collapse
|
26
|
Onoda H, Ueno H, Hashimoto M, Kuwahara H, Sobajima M, Kinugawa K. Clinical Advantages of Using Low Tube Voltage in Third-Generation 192-Slice Dual-Source Computed Tomographic Angiography Before Transcatheter Aortic Valve Implantation. Int Heart J 2019; 60:1091-1097. [PMID: 31484865 DOI: 10.1536/ihj.18-693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Low-voltage computed tomographic angiography (CTA) is a highly effective technique to reduce contrast media volume. We sought to examine the suitability of low tube voltage CTA with a reduced contrast media volume protocol using third-generation 192-slice dual-source CT in patients undergoing transcatheter aortic valve implantation (TAVI). CTA was performed to aid TAVI planning for 40 consecutive patients with severe aortic stenosis. For the first 10 patients (120/100 kV group), we used a conventional tube voltage combined CTA protocol (an ECG-gated helical scan; 120 kV, non-gated helical scan; 100 kV). For the subsequent 30 patients (70-kV group), we adopted a low tube voltage CTA protocol. We evaluated vascular attenuation, image noise, contrast-to-noise ratio (CNR), and renal function. The mean contrast media (CM) volume was 77.7 ± 17.7 mL in the 120/100-kV group and 30.9 ± 6.3 mL in the 70-kV group (P < 0.001). In the images of the aortic valve complex, the mean attenuation was not significant difference for both groups. In the images of the aorto-femoral arteries, mean attenuation was > 250 Hounsfield Units and CNR was > 10 in all vascular segments for both groups. There was no significant difference in the change of renal function in the 70-kV group, but renal function in the 120/100-kV group decreased within 1-3 months after CTA. Low tube voltage CTA using third-generation dual-source CT is suitable to assess procedural planning for TAVI. This approach maintains image quality and reduces the required CM volume.
Collapse
Affiliation(s)
- Hiroshi Onoda
- Second Department of Internal Medicine, University of Toyama
| | - Hiroshi Ueno
- Second Department of Internal Medicine, University of Toyama
| | | | | | - Mitsuo Sobajima
- Second Department of Internal Medicine, University of Toyama
| | | |
Collapse
|
27
|
Hachulla AL, Noble S, Ronot M, Guglielmi G, de Perrot T, Montet X, Vallée JP. Low Iodine Contrast Injection for CT Acquisition Prior to Transcatheter Aortic Valve Replacement: Aorta Assessment and Screening for Coronary Artery Disease. Acad Radiol 2019; 26:e150-e160. [PMID: 30076081 DOI: 10.1016/j.acra.2018.06.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2018] [Revised: 06/17/2018] [Accepted: 06/18/2018] [Indexed: 10/28/2022]
Abstract
RATIONALE AND OBJECTIVES To assess both the complete aorta and coronary artery disease (CAD) using low iodine contrast computed-tomography angiography before transcatheter aortic valve replacement. MATERIALS AND METHODS 84 patients underwent computed-tomography angiography before transcatheter aortic valve replacement: 42 with standard iodine injection protocol (P1:120 mL); 42 with a low dose iodine injection protocol (P2:60 mL). Mean attenuation and subjective image quality were rated at different levels of the aorta, iliac and coronary arteries. Sensitivity, specificity, negative and positive predictive values for depiction of CAD were calculated according to the coronary angiography. RESULTS Mean attenuation was significantly higher in P1 for the ascending aorta (p < 0.001). No significant difference was observed regarding image quality of the aortic valve (p = 0.876), the ascending aorta (p = 0.306), or the abdominal aorta (p = 1.0). Diagnostic image quality of coronary arteries was excellent for P1 and P2 (94.6% vs 96.5%, p = 0.08). Sensitivity, specificity, negative and positive predictive values, and accuracy for depiction of CAD were excellent for P1 and P2 (100% vs 100%; 79% vs 86%, 70% vs 87%, 100% vs 100% and 86% vs 93%) without significant differences (p = 0.93; p = 0.58; p = 0.90; p = 1.0; p = 0.74), respectively. CONCLUSION Despite a difference in aortic mean attenuation, a reduced iodine injection protocol showed similar image quality and detection of CAD in comparison with a standard injection protocol.
Collapse
|
28
|
Blanke P, Weir-McCall JR, Achenbach S, Delgado V, Hausleiter J, Jilaihawi H, Marwan M, Norgaard BL, Piazza N, Schoenhagen P, Leipsic JA. Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr 2019; 13:1-20. [DOI: 10.1016/j.jcct.2018.11.008] [Citation(s) in RCA: 102] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
29
|
Blanke P, Weir-McCall JR, Achenbach S, Delgado V, Hausleiter J, Jilaihawi H, Marwan M, Nørgaard BL, Piazza N, Schoenhagen P, Leipsic JA. Computed Tomography Imaging in the Context of Transcatheter Aortic Valve Implantation (TAVI)/Transcatheter Aortic Valve Replacement (TAVR). JACC Cardiovasc Imaging 2019; 12:1-24. [DOI: 10.1016/j.jcmg.2018.12.003] [Citation(s) in RCA: 192] [Impact Index Per Article: 38.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
30
|
Higuchi R, Tobaru T, Hagiya K, Saji M, Takamisawa I, Shimizu J, Iguchi N, Takanashi S, Takayama M. Renoprotective Transcatheter Aortic Valve Implantation Without Contrast Media. Int Heart J 2018; 59:1469-1472. [PMID: 30249922 DOI: 10.1536/ihj.17-588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The therapeutic role of transcatheter aortic valve implantation (TAVI) in high surgical risk or inoperable cases has been established. Most of the candidates for TAVI are elderly and have multiple comorbidities including chronic kidney disease. However, contrast-enhanced computed tomography and coronary angiography, both of which require iodine contrast media, are essential for pre-procedural planning. In addition, TAVI could have adverse effects on kidney function including contrast media-induced nephrotoxicity. Acute kidney injury following TAVI has been reported to be related to poor prognosis. In a case with advanced renal dysfunction, we successfully avoided post-procedural acute kidney injury by performing pre-procedural evaluation using minimal contrast and TAVI without contrast media. If anatomical conditions and experiences of the heart team are adequate, renoprotective TAVI should be a favorable therapy for patients with aortic stenosis complicated by renal dysfunction.
Collapse
Affiliation(s)
| | | | | | - Mike Saji
- Department of Cardiology, Sakakibara Heart Institute
| | | | - Jun Shimizu
- Department of Anesthesiology, Sakakibara Heart Institute
| | - Nobuo Iguchi
- Department of Cardiology, Sakakibara Heart Institute
| | | | | |
Collapse
|
31
|
Miyazaki Y, Abdelghani M, de Boer ES, Aben JP, van Sloun M, Suchecki T, van 't Veer M, Collet C, Asano T, Katagiri Y, Tenekecioglu E, Soliman OII, Onuma Y, de Winter R, Tonino P, van de Vosse FN, Rutten MCM, Serruys PW. A novel synchronised diastolic injection method to reduce contrast volume during aortography for aortic regurgitation assessment: in vitro experiment of a transcatheter heart valve model. EUROINTERVENTION 2018; 13:1288-1295. [PMID: 28691911 DOI: 10.4244/eij-d-17-00355] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS In the minimalist transcatheter aortic valve implantation (TAVI) era, the usage of transoesophageal echocardiography has become restricted. Conversely, aortography has gained clinical ground in quantifying prosthetic valve regurgitation (PVR) during the procedure. In a mock circulation system, we sought to compare the contrast volume required and the accuracy of aortographic videodensitometric PVR assessment using a synchronised diastolic and standard (non-synchronised) injection aortography. METHODS AND RESULTS Synchronised diastolic injection triggered by the signal stemming from the mock circulation was compared with standard non-synchronised injection. A transcatheter heart valve was implanted and was deformed step by step by advancing a screw perpendicularly to the cage of the valve in order to create increasing PVR. Quantitative measurement of PVR was derived from time-density curves of both a reference area (aortic root) and a region of interest (left ventricle) developed by a videodensitometric software. The volume of contrast required for the synchronised diastolic injection was significantly less than in the non-synchronised injection (8.1 [7.9-8.5] ml vs. 19.4 [19.2-19.9] ml, p<0.001). The correlation between the two methods was substantial (Spearman's coefficient rho ranging from 0.991 to 0.968). Intraobserver intra-class correlation coefficient for both methods of injection was 0.999 (95% CI: 0.996-1.000) for the synchronised diastolic and 0.999 (95% CI: 0.996-1.000) for the non-synchronised injection group. The mean difference in the rating was 0.17% and limits of agreement were ±1.64% for both groups. CONCLUSIONS A short synchronised diastolic injection enables contrast volume reduction during aortography without compromising the accuracy of the quantitative assessment of PVR using videodensitometry.
Collapse
Affiliation(s)
- Yosuke Miyazaki
- Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Annoni AD, Andreini D, Pontone G, Mancini ME, Formenti A, Mushtaq S, Baggiano A, Conte E, Guglielmo M, Muscogiuri G, Muratori M, Fusini L, Trabattoni D, Teruzzi G, Coutinho Santos AI, Agrifoglio M, Pepi M. CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree. Br J Radiol 2018; 91:20180196. [PMID: 30004788 DOI: 10.1259/bjr.20180196] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVE: To evaluate feasibility, image quality and accuracy of a reduced contrast volume protocol for pre-procedural CT imaging in transcatheter aortic valve implantation (TAVI) using a third generation wide array CT scanner. METHODS: 115 consecutive patients (51F, mean age 82.5 ± 6.2 y, mean BMI 26.7 ± 3.6) referred for TAVI were examined with wide-array CT scanner with a combined scan protocol and a total amount of 50 ml contrast agent. A 4-point visual scale (4-1) was used to assess image quality . Contrast attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries. Coronary tree was assessed and compared with invasive coronary angiography (ICA). Aortic annulus measurements were compared with final procedural results. Patients creatinine was monitored at the baseline and 72 h after procedure. RESULTS: Median quality score value was >3. Mean CNR at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries were 14.8 ± 2.3, 15.7 ± 1.7, 14.9 ± 3.1, 15.8 ± 4.7, 20.3 ± 9.9, 20.8 ± 6.9 respectively. Only 1 patient had moderate paravalvular regurgitation. In comparison with ICA for coronary assessment CTA showed in a segment based analysis sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 97, 85, 99,62 and 88% respectively. Mean creatinine before CT and 72 h after procedure were 1.21 ± 0.52 and1.22 ± 0.49 mg dl-1. Mean DLP was 442.4 ± 21.2 mGy/cm. CONCLUSION: CT with low contrast volume is feasible and clinically useful, allowing precise pre-procedural TAVI planning with accurate assessment of coronary tree. ADVANCES IN KNOWLEDGE: third generation CT scanner with whole heart coverage allows examinations for assessment of aorta and coronary arteries in TAVI planning using low dose of contrast medium maintaining good quality and high diagnostic accuracy.
Collapse
Affiliation(s)
- Andrea D Annoni
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Daniele Andreini
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Gianluca Pontone
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | | | - Alberto Formenti
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Saima Mushtaq
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | | | - Edoardo Conte
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Marco Guglielmo
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Giuseppe Muscogiuri
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Manuela Muratori
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Laura Fusini
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Daniela Trabattoni
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Giovanni Teruzzi
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Ana I Coutinho Santos
- 2 Imaging Department, Centro Hospitalar de Lisboa Ocidental, E.P.E , Lisboa , Portugal
| | - Marco Agrifoglio
- 3 Department of Clinical Sciences and Community Health, University of Milan , Milan , Italy.,4 Cardiac Surgery Department, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Mauro Pepi
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| |
Collapse
|
33
|
Abstract
Non-invasive imaging of the aorta has undergone considerable advancements in recent times; largely driven by the technological advances in computed tomography (CT) and magnetic resonance imaging (MRI). This review article highlights these recent advancements and discusses the current role of different imaging tools in the management of aortic diseases.
Collapse
Affiliation(s)
- Vinit Baliyan
- Division of Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Daniel Verdini
- Division of Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Nandini M Meyersohn
- Division of Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
34
|
Scholtz JE, Ghoshhajra B. Advances in cardiac CT contrast injection and acquisition protocols. Cardiovasc Diagn Ther 2017; 7:439-451. [PMID: 29255688 PMCID: PMC5716940 DOI: 10.21037/cdt.2017.06.07] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 05/25/2017] [Indexed: 01/27/2023]
Abstract
Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors.
Collapse
Affiliation(s)
- Jan-Erik Scholtz
- Cardiac MR PET CT Program, Department of Radiology (Cardiovascular Imaging) and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Brian Ghoshhajra
- Cardiac MR PET CT Program, Department of Radiology (Cardiovascular Imaging) and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
35
|
Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols. Eur J Radiol Open 2017; 4:75-83. [PMID: 28702479 PMCID: PMC5491755 DOI: 10.1016/j.ejro.2017.06.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2017] [Revised: 06/04/2017] [Accepted: 06/18/2017] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND ECG-gated cardiac computed tomography angiography (CCTA) has found widespread use for prosthesis sizing before transcatheter aortic valve implantation (TAVI). However, still little data exists on the optimal scan-strategy in such patients. We hypothesized that prospectively triggered CCTA can enable the visualization of aortic valve structures and peripheral arteries with lower radiation and contrast agent exposure in patients considered for TAVI compared to retrospectively gated protocols. METHODS All studies were performed using a 256 multi-detector single source CT (iCT Philips, Best, Netherlands). With the prospective protocol the whole volume from the heart to the iliofemoral arteries scanned using prospective triggering. With the retrospective protocol a first retrospectively gated scan was performed for the heart and the iliofemoral part was subsequently scanned using a second non-triggered scan. Image quality was assessed semi-quantitatively and signal-to-noise- (SNR) and contrast-to-noise-ratios (CNR) were obtained for all scans. RESULTS Prospective CCTA was performed in 74 and in 34 patients, respectively using non-tailored and BMI adapted scans, whereas retrospective CCTA was performed in 57 patients. Prospective scans required lower contrast agent administration compared to retrospective scans (71 ± 8 mL versus 91 ± 15 mL, p < 0.01) and resulted in lower radiation exposure (26 ± 7mSv for retrospective versus 15 ± 3mSv for non-tailored prospective versus 8 ± 4mSv for BMI-adapted prospective scans, p < 0.01). Visual image quality was better for the evaluation of aortic valve structures and similar for the assessment of iliofemoral anatomy with prospective versus retrospective scans. In addition, contrast density, SNR and CNR were higher in the ascending aorta with prospective versus retrospective CCTA (434 ± 98HU versus 349 ± 112HU; 35 ± 14 versus 24 ± 9 and 31 ± 11 versus 16 ± 7, p < 0.001 for all). Subsection analysis by heart rate groups demonstrated that both image quality and CNR were significantly higher in patients with prospective versus retrospective CCTA, irrespective of the heart rate during image acquisition. CONCLUSION Prospectively triggered CCTA allows for improved visualization of aortic valve structures and peripheral arteries in patients scheduled for TAVI with simultaneously reduced contrast agent dose and radiation exposure. Therefore, this acquisition mode seems to be the preferred for the evaluation of patients considered for TAVI.
Collapse
|
36
|
Role of CT Imaging for Coronary and Non-coronary Interventions. CURRENT CARDIOVASCULAR IMAGING REPORTS 2017. [DOI: 10.1007/s12410-017-9410-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
37
|
Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning. Eur Radiol 2016; 27:1944-1953. [PMID: 27553939 DOI: 10.1007/s00330-016-4537-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Revised: 06/13/2016] [Accepted: 08/01/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. RESULTS Besides a higher body-mass-index in group B (24.8±3.8 kg/m2 vs. 28.1±5.4 kg/m2, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). CONCLUSION TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. KEY POINTS • Third-generation dual-source CT facilitates low-tube-voltage acquisition. • TAVR planning can be performed with reduced contrast volume and radiation dose. • TAVR-planning CT did not result in changes in creatinine levels at follow-up. • TAVR candidates can be safely evaluated by comprehensive low-tube-voltage CT angiography.
Collapse
|
38
|
Khalique OK, Pulerwitz TC, Halliburton SS, Kodali SK, Hahn RT, Nazif TM, Vahl TP, George I, Leon MB, D'Souza B, Einstein AJ. Practical considerations for optimizing cardiac computed tomography protocols for comprehensive acquisition prior to transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr 2016; 10:364-74. [PMID: 27475972 DOI: 10.1016/j.jcct.2016.07.007] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2016] [Accepted: 07/03/2016] [Indexed: 01/07/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) is performed frequently in patients with severe, symptomatic aortic stenosis who are at high risk or inoperable for open surgical aortic valve replacement. Computed tomography angiography (CTA) has become the gold standard imaging modality for pre-TAVR cardiac anatomic and vascular access assessment. Traditionally, cardiac CTA has been most frequently used for assessment of coronary artery stenosis, and scanning protocols have generally been tailored for this purpose. Pre-TAVR CTA has different goals than coronary CTA and the high prevalence of chronic kidney disease in the TAVR patient population creates a particular need to optimize protocols for a reduction in iodinated contrast volume. This document reviews details which allow the physician to tailor CTA examinations to maximize image quality and minimize harm, while factoring in multiple patient and scanner variables which must be considered in customizing a pre-TAVR protocol.
Collapse
Affiliation(s)
- Omar K Khalique
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA.
| | - Todd C Pulerwitz
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | | | - Susheel K Kodali
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Rebecca T Hahn
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Tamim M Nazif
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Torsten P Vahl
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Isaac George
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Martin B Leon
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Belinda D'Souza
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| | - Andrew J Einstein
- Columbia University Medical Center/New York Presbyterian Hospital, New York, NY, USA
| |
Collapse
|