1
|
Biggemann L, Uhlig J, Streit U, Al-Bourini O, Wedi E, Amanzada A, Ellenrieder V, Rühlmann F, Ghadimi M, Frahm J, Uecker M, Seif Amir Hosseini A. Visualization of deglutition and gastroesophageal reflux using real-time MRI: a standardized approach to image acquisition and assessment. Sci Rep 2023; 13:22854. [PMID: 38129469 PMCID: PMC10739804 DOI: 10.1038/s41598-023-49776-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 12/12/2023] [Indexed: 12/23/2023] Open
Abstract
This study aims to develop a standardized algorithm for gastroesophageal image acquisition and diagnostic assessment using real-time MRI. Patients with GERD symptoms undergoing real-time MRI of the esophagus and esophagogastric junction between 2015 and 2018 were included. A 10 ml bolus of pineapple juice served as an oral contrast agent. Patients performed Valsalva maneuver to provoke reflux and hiatal hernia. Systematic MRI assessment included visual presence of achalasia, fundoplication failure in patients with previous surgical fundoplication, gastroesophageal reflux, and hiatal hernia. A total of 184 patients (n = 92 female [50%], mean age 52.7 ± 15.8 years) completed MRI studies without adverse events at a mean examination time of 15 min. Gastroesophageal reflux was evident in n = 117 (63.6%), hiatal hernia in n = 95 (52.5%), and achalasia in 4 patients (2.2%). Hiatal hernia was observed more frequently in patients with reflux at rest (n = 67 vs. n = 6, p < 0.01) and during Valsalva maneuver (n = 87 vs. n = 8, p < 0.01). Real-time MRI visualized a morphologic correlate for recurring GERD symptoms in 20/22 patients (90%) after fundoplication procedure. In a large-scale single-center cohort of patients with GERD symptoms undergoing real-time MRI, visual correlates for clinical symptoms were evident in most cases. The proposed assessment algorithm could aid in wider-spread utilization of real-time MRI and provides a comprehensive approach to this novel imaging modality.
Collapse
Affiliation(s)
- Lorenz Biggemann
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.
| | - Johannes Uhlig
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Ulrike Streit
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Department of Radiology, Klinikum Rechts Der Isar, School of Medicine, Technical University of Munich, München, Germany
| | - Omar Al-Bourini
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
- Department of Gastroenterology, Gastrointestinal Oncology and Interventional Endoscopy, Sana Klinikum, Offenbach, Germany
| | - Ahmad Amanzada
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Felix Rühlmann
- Department of General, Visceral, and Paediatric Surgery, University Medical Center, Göttingen, Germany
| | - Michael Ghadimi
- Department of General, Visceral, and Paediatric Surgery, University Medical Center, Göttingen, Germany
| | - Jens Frahm
- Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
| | - Martin Uecker
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Göttingen, Germany
| | - Ali Seif Amir Hosseini
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| |
Collapse
|
2
|
Hirsch FW, Frahm J, Sorge I, Klee D, Prenzel F, Krause M, Lacher M, Voit D, Gräfe D. Real-time MRI: a new tool of radiologic imaging in small children. Eur J Pediatr 2023; 182:3405-3417. [PMID: 37249681 PMCID: PMC10460313 DOI: 10.1007/s00431-023-04996-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/19/2023] [Accepted: 04/20/2023] [Indexed: 05/31/2023]
Abstract
Real-time MRI (rt-MRI) in children is a new imaging technique that combines the advantages of US - at frame rates of up to 50 images per second - with the quality and features of MRI. Although still subject of research, it has become a standard tool in the diagnostic portfolio of two pediatric radiology departments in Germany. Based on ultrashort acquisition times, any detrimental effects of macroscopic movements of the child and the physiological movements of the organs are negligible. Especially in pediatric brain imaging, rt-MRI has already proven its value. With suitable indications, rt-MRI can reduce anesthesia and sedation examinations in children below 6 years of age by 40% due to its very short examination time and its robustness to motion. There is a high level of acceptance among parents and referrers when diagnostic possibilities and limitations are communicated correctly. CONCLUSION Completely new diagnostic possibilities arise in the imaging of the moving lung, the beating heart, joint movements, and speaking and swallowing, as demonstrated in this video-backed review. WHAT IS KNOWN • MRI in moving children has been burdened with severe artifacts. • Gross motion usually has to be handled by sedation and periodic motion of the heart and lungs has to be compensated with time-consuming techniques until now. WHAT IS NEW • Real-time MRI allows image acquisition with up to 50 frames per second similar to ultrasound frame rate. • Real-time MRI proofs to be very promising for imaging children, reducing examination time and sedation rate drastically.
Collapse
Affiliation(s)
| | - Jens Frahm
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Gottingen, Germany
| | - Ina Sorge
- Department of Pediatric Radiology, University Hospital, Leipzig, Germany
| | - Dirk Klee
- Department of Radiology, University Hospital, Dusseldorf, Germany
| | - Freerk Prenzel
- Department of Pediatrics, University Hospital, Leipzig, Germany
| | - Matthias Krause
- Department of Neurosurgery, University Hospital, Leipzig, Germany
| | - Martin Lacher
- Department of Pediatrics Surgery, University Hospital, Leipzig, Germany
| | - Dirk Voit
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Gottingen, Germany
| | - Daniel Gräfe
- Department of Pediatric Radiology, University Hospital, Leipzig, Germany
| |
Collapse
|
3
|
Nayak KS, Lim Y, Campbell-Washburn AE, Steeden J. Real-Time Magnetic Resonance Imaging. J Magn Reson Imaging 2022; 55:81-99. [PMID: 33295674 PMCID: PMC8435094 DOI: 10.1002/jmri.27411] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 10/06/2020] [Accepted: 10/09/2020] [Indexed: 01/03/2023] Open
Abstract
Real-time magnetic resonance imaging (RT-MRI) allows for imaging dynamic processes as they occur, without relying on any repetition or synchronization. This is made possible by modern MRI technology such as fast-switching gradients and parallel imaging. It is compatible with many (but not all) MRI sequences, including spoiled gradient echo, balanced steady-state free precession, and single-shot rapid acquisition with relaxation enhancement. RT-MRI has earned an important role in both diagnostic imaging and image guidance of invasive procedures. Its unique diagnostic value is prominent in areas of the body that undergo substantial and often irregular motion, such as the heart, gastrointestinal system, upper airway vocal tract, and joints. Its value in interventional procedure guidance is prominent for procedures that require multiple forms of soft-tissue contrast, as well as flow information. In this review, we discuss the history of RT-MRI, fundamental tradeoffs, enabling technology, established applications, and current trends. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Krishna S. Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA,Address reprint requests to: K.S.N., 3740 McClintock Ave, EEB 400C, Los Angeles, CA 90089-2564, USA.
| | - Yongwan Lim
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Adrienne E. Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Jennifer Steeden
- Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, University College London, London, UK
| |
Collapse
|
4
|
Biggemann L, Uhlig J, Gliem N, Al-Bourini O, Wedi E, Ellenrieder V, Ghadimi M, Uecker M, Frahm J, Lotz J, Hosseini ASA, Streit U. Assessment of esophagogastric junction morphology by dynamic real-time MRI: comparison of imaging features to high-resolution manometry. Jpn J Radiol 2021; 40:376-384. [PMID: 34874494 PMCID: PMC8977262 DOI: 10.1007/s11604-021-01210-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 10/11/2021] [Indexed: 11/30/2022]
Abstract
Purpose To assess the esophagogastric junction (EGJ) on real-time MRI and compare imaging parameters to EGJ morphology on high-resolution manometry (HRM). Methods A total of 105 of 117 eligible patients who underwent real-time MRI and high-resolution manometry for GERD-like symptoms between 2015 and 2018 at a single center were retrospectively evaluated (male n = 57; female n = 48; mean age 52.5 ± 15.4 years). Real-time MRI was performed at a median investigation time of 15 min (1 frame/40 ms). On HRM, EGJ morphology was assessed according to the Chicago classification of esophageal motility disorders. Real-time MRI was performed at 3 T using highly undersampled radial fast low-angle shot acquisitions with NLINV image reconstruction. A 10 mL pineapple juice bolus served as oral contrast agent at supine position. Real-time MRI films of the EGJ were acquired during swallowing events and during Valsalva maneuver. Anatomic and functional MRI parameters were compared to EGJ morphology on HRM. Results On HRM, n = 42 patients presented with EGJ type I (40.0%), n = 33 with EGJ type II (31.4%), and n = 30 with EGJ type III (28.6%). On real-time MRI, hiatal hernia was more common in patients with EGJ type III (66.7%) than in patients with EGJ type I (26.2%) and EGJ type II (30.3%; p < 0.001). Sliding hiatal hernia was more frequent in patients with EGJ type II (33.3%) than in patients with EGJ type III (16.7%) and EGJ type I (7.1%; p = 0.017). The mean esophagus–fundus angle of patients was 85 ± 31° at rest and increased to 101 ± 36° during Valsalva maneuver. Conclusion Real-time MRI is a non-invasive imaging method for assessment of the esophagogastric junction. Real-time MRI can visualize dynamic changes of the EGJ during swallowing events. Supplementary Information The online version contains supplementary material available at 10.1007/s11604-021-01210-9.
Collapse
Affiliation(s)
- Lorenz Biggemann
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.
| | - Johannes Uhlig
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Nina Gliem
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Omar Al-Bourini
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Michael Ghadimi
- Department of General, Visceral, and Paediatric Surgery, University Medical Center, Göttingen, Germany
| | - Martin Uecker
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Jens Frahm
- Biomedical NMR, Max-Planck-Institute for Biophysical Chemistry, Göttingen, Germany
| | - Joachim Lotz
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Ali Seif Amir Hosseini
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Ulrike Streit
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| |
Collapse
|
5
|
Performance of a new natural oral contrast agent (LumiVision®) in dynamic MR swallowing. Eur Radiol 2021; 31:8578-8585. [PMID: 33893856 PMCID: PMC8523424 DOI: 10.1007/s00330-021-07927-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 02/17/2021] [Accepted: 03/23/2021] [Indexed: 11/24/2022]
Abstract
Objectives To evaluate image quality by first use of LumiVision® in dynamic MR swallowing, a contrast medium consisting of biological substances versus a gadolinium-buttermilk mixture in patients who underwent Nissen fundoplication due to gastroesophageal reflux disease (GERD). Methods The protocol of this retrospective study was approved by the local Institutional Review Board. A hundred twenty-nine patients (146 examinations) underwent a dynamic MR swallowing study (at 1.5 T or 3.0 T) and received an oral contrast agent. Two readers evaluated the distention of the esophagus, contrast, and traceability of the bolus in a 3-point scale. A steady-state coherent sequence (B-FFE, TrueFISP) was used. The patients were divided into 3 different groups: 53 patients received gadolinium chelate (Dotarem®)–buttermilk mixture (GBM) in a dilution of 1:40 as an oral contrast agent; 44 patients received LumiVision® water mixture (LWM) in a dilution of 1:1 and 49 patients received LumiVision® (L) undiluted. Results GBM showed significantly better results in overall evaluation for both readers in contrast to LWM (p = .003, p = .002). L also reached significantly better results in overall evaluation than LWM in both readers (p = .004, p = .042). There was no significant difference in the overall evaluation between L and GBM (p = .914, p = .376).According to Landis and Koch, interobserver agreement was “substantial” (Cohen’s kappa = 0.738) between both readers. Conclusion LumiVision® undiluted showed equal image quality compared to gadolinium-buttermilk mixture. The constellation of LumiVision® water mixture led to a clearly negative result in relation to the image quality compared to LumiVision® undiluted. Therefore, oral ingestion of LumiVision® undiluted is recommended for MR swallowing examinations. Key Points • LumiVision® undiluted shows significantly better image quality in comparison to LumiVision® diluted in oral application in swallowing MRI. • LumiVision® undiluted shows equal image quality in comparison to gadolinium-buttermilk mixture in oral application. • Oral ingestion of LumiVision® undiluted can replace gadolinium-buttermilk mixture in oral MR examinations.
Collapse
|
6
|
Biggemann L, Uhlig J, Gliem N, Al-Bourini O, Wedi E, Ellenrieder V, Ghadimi M, Uecker M, Frahm J, Lotz J, Hosseini ASA, Streit U. Assessment of esophageal motility disorders by real-time MRI. Eur J Radiol 2020; 132:109265. [PMID: 33010683 DOI: 10.1016/j.ejrad.2020.109265] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 07/08/2020] [Accepted: 08/10/2020] [Indexed: 12/25/2022]
Abstract
PURPOSE To investigate imaging findings of esophageal motility disorders on dynamic real-time. MATERIAL AND METHODS 102 patients with GERD-like symptoms were included in this retrospective study between 2015-2018. Dynamic real-time MRI visualized the transit of a 10 mL pineapple juice bolus through the esophagus and EGJ with a temporal resolution of 40 ms. Dynamic and anatomic parameters were measured by consensus reading. Imaging findings were compared to HRM utilizing the Chicago classification of esophageal motility disorders, v3.0. RESULTS All 102 patients completed real-time MRI in a median examination time of 15 min. On HRM, 14 patients presented with disorders with EGJ outlet obstruction (EGJOO) (13.7 %), 7 patients with major disorders of peristalsis (6.9 %), and 32 patients with minor disorders of peristalsis (31.4 %). HRM was normal in 49 patients (48.0 %). Incomplete bolus clearance was significantly more frequent in patients with esophageal motility disorders on HRM than in patients with normal HRM (p = 0.0002). In patients with motility disorders with EGJOO and major disorders of peristalsis, the esophageal diameter tended to be wider (23.6 ± 8.0 vs. 21.2 ± 3.5 mm, p = 0.089) and the sphincter length longer (19.7 ± 7.3 vs. 16.7 ± 3.0 mm, p = 0.091) compared to patients with normal HRM. 3/7 patients with achalasia type II were correctly identified by real-time MRI and one further achalasia type II patient was diagnosed with a motility disorder on MRI films. The other 3/7 patients presented no specific imaging features. CONCLUSION Real-time MRI is an auxiliary diagnostic tool for the assessment of swallowing events. Imaging parameters may assist in the detection of esophageal motility disorders.
Collapse
Affiliation(s)
- Lorenz Biggemann
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany.
| | - Johannes Uhlig
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany
| | - Nina Gliem
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Germany
| | - Omar Al-Bourini
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany
| | - Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Germany
| | - Michael Ghadimi
- Department of General, Visceral, and Paediatric Surgery, University Medical Center, Göttingen, Germany
| | - Martin Uecker
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany
| | - Jens Frahm
- Biomedical NMR, Max-Planck-Institute for Biophysical Chemistry, Göttingen, Germany
| | - Joachim Lotz
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany
| | - Ali Seif Amir Hosseini
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany
| | - Ulrike Streit
- Department of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Germany
| |
Collapse
|
7
|
Seif Amir Hosseini A, Uhlig J, Streit U, Gliem N, Wedi E, Ellenrieder V, Ghadimi M, Ahmed S, Uecker M, Frahm J, Lotz J, Biggemann L. Real-time MRI for dynamic assessment of gastroesophageal reflux disease: Comparison to pH-metry and impedance. Eur J Radiol 2020; 125:108856. [PMID: 32062571 DOI: 10.1016/j.ejrad.2020.108856] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 01/14/2020] [Accepted: 01/24/2020] [Indexed: 01/10/2023]
Abstract
PURPOSE To evaluate the diagnostic potential of real-time MRI for dynamic assessment of gastroesophageal reflux in patients with GERD (gastroesophageal reflux disease)-like symptoms compared to pH-metry and impedance. METHODS Patients who underwent real-time MRI and pH-metry between 2015-2018 were included in this retrospective study. Real-time MRI at 3 T was achieved by undersampled radial FLASH acquisitions with iterative image reconstruction by NLINV. Real-time MRI visualized transit of pineapple juice through the gastroesophageal junction and during Valsalva maneuver. MRI results were compared to 24 h pH-metry to assess acidic reflux (following Lyon Consensus guidelines) and to impedance to assess non-acidic reflux. A standard 2 × 2 table was chosen to calculate diagnostic performance. RESULTS 91/93 eligible patients fulfilled inclusion criteria (male n = 49; female n = 42; median age 55 y). All MRI studies were successfully completed without adverse events at a mean examination time of 15 min. On real-time MRI, reflux was evident in 60 patients (66 %). pH-metry revealed reflux in 41 patients (45 %), and impedance in 54 patients (59 %). Compared to pH-metry and impedance, real-time MRI sensitivity was 0.78 (95 % CI: 0.66-0.87), specificity 0.67 (95 % CI: 0.45-0.84) and PPV 0.87 (95 % CI: 0.75-0.94). CONCLUSION Real-time MRI is an imaging method for assessment of gastroesophageal reflux in patients with GERD-like symptoms. Considering its high positive predictive value, real-time MRI can accurately identify patients in which further invasive testing with pH-metry and impedance might be considered.
Collapse
Affiliation(s)
- Ali Seif Amir Hosseini
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany.
| | - Johannes Uhlig
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany
| | - Ulrike Streit
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany
| | - Nina Gliem
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center, Göttingen, Germany
| | - Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center, Göttingen, Germany
| | - Michael Ghadimi
- Department of General, Visceral, and Paediatric Surgery, University Medical Center, Göttingen, Germany
| | - Saheeb Ahmed
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany
| | - Martin Uecker
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site, Göttingen, Germany
| | - Jens Frahm
- Biomedical NMR, Max-Planck-Institute for Biophysical Chemistry, Göttingen, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site, Göttingen, Germany
| | - Joachim Lotz
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site, Göttingen, Germany
| | - Lorenz Biggemann
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, 37075, Germany
| |
Collapse
|
8
|
|
9
|
Hiatal hernias in patients with GERD-like symptoms: evaluation of dynamic real-time MRI vs endoscopy. Eur Radiol 2019; 29:6653-6661. [DOI: 10.1007/s00330-019-06284-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/17/2019] [Accepted: 05/24/2019] [Indexed: 12/11/2022]
|