You Y, Zhong S, Zhang G, Wen Y, Guo D, Li W, Li Z. Exploring the Low-Dose Limit for Focal Hepatic Lesion Detection with a Deep Learning-Based CT Reconstruction Algorithm: A Simulation Study on Patient Images. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024:10.1007/s10278-024-01080-3. [PMID: 38502435 DOI: 10.1007/s10278-024-01080-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 03/06/2024] [Accepted: 03/07/2024] [Indexed: 03/21/2024]
Abstract
This study aims to investigate the maximum achievable dose reduction for applying a new deep learning-based reconstruction algorithm, namely the artificial intelligence iterative reconstruction (AIIR), in computed tomography (CT) for hepatic lesion detection. A total of 40 patients with 98 clinically confirmed hepatic lesions were retrospectively included. The mean volume CT dose index was 13.66 ± 1.73 mGy in routine-dose portal venous CT examinations, where the images were originally obtained with hybrid iterative reconstruction (HIR). Low-dose simulations were performed in projection domain for 40%-, 20%-, and 10%-dose levels, followed by reconstruction using both HIR and AIIR. Two radiologists were asked to detect hepatic lesion on each set of low-dose image in separate sessions. Qualitative metrics including lesion conspicuity, diagnostic confidence, and overall image quality were evaluated using a 5-point scale. The contrast-to-noise ratio (CNR) for lesion was also calculated for quantitative assessment. The lesion CNR on AIIR at reduced doses were significantly higher than that on routine-dose HIR (all p < 0.05). Lower qualitative image quality was observed as the radiation dose reduced, while there were no significant differences between 40%-dose AIIR and routine-dose HIR images. The lesion detection rate was 100%, 98% (96/98), and 73.5% (72/98) on 40%-, 20%-, and 10%-dose AIIR, respectively, whereas it was 98% (96/98), 73.5% (72/98), and 40% (39/98) on the corresponding low-dose HIR, respectively. AIIR outperformed HIR in simulated low-dose CT examinations of the liver. The use of AIIR allows up to 60% dose reduction for lesion detection while maintaining comparable image quality to routine-dose HIR.
Collapse
Affiliation(s)
- Yongchun You
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | | | | | - Yuting Wen
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Dian Guo
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Wanjiang Li
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| |
Collapse
|
2
|
Prod'homme S, Bouzerar R, Forzini T, Delabie A, Renard C. Detection of urinary tract stones on submillisievert abdominopelvic CT imaging with deep-learning image reconstruction algorithm (DLIR). Abdom Radiol (NY) 2024:10.1007/s00261-024-04223-w. [PMID: 38470506 DOI: 10.1007/s00261-024-04223-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 01/23/2024] [Accepted: 01/24/2024] [Indexed: 03/14/2024]
Abstract
PURPOSE Urolithiasis is a chronic condition that leads to repeated CT scans throughout the patient's life. The goal was to assess the diagnostic performance and image quality of submillisievert abdominopelvic computed tomography (CT) using deep learning-based image reconstruction (DLIR) in urolithiasis. METHODS 57 patients with suspected urolithiasis underwent both non-contrast low-dose (LD) and ULD abdominopelvic CT. Raw image data of ULD CT were reconstructed using hybrid iterative reconstruction (ASIR-V 70%) and high-strength-level DLIR (DLIR-H). The performance of ULD CT for the detection of urinary stones was assessed by two readers and compared with LD CT with ASIR-V 70% as a reference standard. Image quality was assessed subjectively and objectively. RESULTS 266 stones were detected in 38 patients. Mean effective dose was 0.59 mSv for ULD CT and 1.96 mSv for LD CT. For diagnostic performance, sensitivity and specificity were 89% and 94%, respectively, for ULDCT with DLIR-H. There was an almost perfect intra-observer concordance on ULD CT with DLIR-H versus LDCT with ASIR-V 70% (ICC = 0.90 and 0.90 for the two readers). Image noise was significantly lower and signal-to-noise ratio significantly higher with DLIR-H compared to ASIR-V 70%. Subjective image quality was also significantly better with ULDCT with DLIR-H. CONCLUSION ULD CT with Deep Learning Image Reconstruction maintains a good diagnostic performance in urolithiasis, with better image quality than hybrid iterative reconstruction and a significant radiation dose reduction.
Collapse
Affiliation(s)
- Sarah Prod'homme
- Department of Radiology, Amiens University Hospital, 1 Rond-Point du Professeur Christian Cabrol, 80054, Amiens Cedex 01, France
| | - Roger Bouzerar
- Biophysics and Image Processing Unit, Amiens University Hospital, Amiens, France
| | - Thomas Forzini
- Department of Urology and Transplantation, Amiens University Hospital, Amiens, France
| | - Aurélien Delabie
- Department of Radiology, Amiens University Hospital, 1 Rond-Point du Professeur Christian Cabrol, 80054, Amiens Cedex 01, France
| | - Cédric Renard
- Department of Radiology, Amiens University Hospital, 1 Rond-Point du Professeur Christian Cabrol, 80054, Amiens Cedex 01, France.
| |
Collapse
|
3
|
Shim JH, Choi SY, Chang IH, Park SB. Dose Optimization Using a Deep Learning Tool in Various CT Protocols for Urolithiasis: A Physical Human Phantom Study. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1677. [PMID: 37763796 PMCID: PMC10538199 DOI: 10.3390/medicina59091677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 09/12/2023] [Accepted: 09/14/2023] [Indexed: 09/29/2023]
Abstract
Background and Objectives: We attempted to determine the optimal radiation dose to maintain image quality using a deep learning application in a physical human phantom. Materials and Methods: Three 5 × 5 × 5 mm3 uric acid stones were placed in a physical human phantom in various locations. Three tube voltages (120, 100, and 80 kV) and four current-time products (100, 70, 30, and 15 mAs) were implemented in 12 scans. Each scan was reconstructed with filtered back projection (FBP), statistical iterative reconstruction (IR, iDose), and knowledge-based iterative model reconstruction (IMR). By applying deep learning to each image, we took 12 more scans. Objective image assessments were calculated using the standard deviation of the Hounsfield unit (HU). Subjective image assessments were performed by one radiologist and one urologist. Two radiologists assessed the subjective assessment and found the stone under the absence of information. We used this data to calculate the diagnostic accuracy. Results: Objective image noise was decreased after applying a deep learning tool in all images of FBP, iDose, and IMR. There was no statistical difference between iDose and deep learning-applied FBP images (10.1 ± 11.9, 9.5 ± 18.5 HU, p = 0.583, respectively). At a 100 kV-30 mAs setting, deep learning-applied FBP obtained a similar objective noise in approximately one third of the radiation doses compared to FBP. In radiation doses with settings lower than 100 kV-30 mAs, the subject image assessment (image quality, confidence level, and noise) showed deteriorated scores. Diagnostic accuracy was increased when the deep learning setting was lower than 100 kV-30 mAs, except for at 80 kV-15 mAs. Conclusions: At the setting of 100 kV-30 mAs or higher, deep learning-applied FBP did not differ in image quality compared to IR. At the setting of 100 kV-30 mAs, the radiation dose can decrease by about one third while maintaining objective noise.
Collapse
Affiliation(s)
- Jae Hun Shim
- Department of Urology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Republic of Korea
| | - Se Young Choi
- Department of Urology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Republic of Korea
| | - In Ho Chang
- Department of Urology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Republic of Korea
| | - Sung Bin Park
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul 06973, Republic of Korea
| |
Collapse
|
4
|
Terzis R, Reimer RP, Nelles C, Celik E, Caldeira L, Heidenreich A, Storz E, Maintz D, Zopfs D, Große Hokamp N. Deep-Learning-Based Image Denoising in Imaging of Urolithiasis: Assessment of Image Quality and Comparison to State-of-the-Art Iterative Reconstructions. Diagnostics (Basel) 2023; 13:2821. [PMID: 37685359 PMCID: PMC10486912 DOI: 10.3390/diagnostics13172821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 08/23/2023] [Accepted: 08/25/2023] [Indexed: 09/10/2023] Open
Abstract
This study aimed to compare the image quality and diagnostic accuracy of deep-learning-based image denoising reconstructions (DLIDs) to established iterative reconstructed algorithms in low-dose computed tomography (LDCT) of patients with suspected urolithiasis. LDCTs (CTDIvol, 2 mGy) of 76 patients (age: 40.3 ± 5.2 years, M/W: 51/25) with suspected urolithiasis were retrospectively included. Filtered-back projection (FBP), hybrid iterative and model-based iterative reconstruction (HIR/MBIR, respectively) were reconstructed. FBP images were processed using a Food and Drug Administration (FDA)-approved DLID. ROIs were placed in renal parenchyma, fat, muscle and urinary bladder. Signal- and contrast-to-noise ratios (SNR/CNR, respectively) were calculated. Two radiologists evaluated image quality on five-point Likert scales and urinary stones. The results showed a progressive decrease in image noise from FBP, HIR and DLID to MBIR with significant differences between each method (p < 0.05). SNR and CNR were comparable between MBIR and DLID, while it was significantly lower in HIR followed by FBP (e.g., SNR: 1.5 ± 0.3; 1.4 ± 0.4; 1.0 ± 0.3; 0.7 ± 0.2, p < 0.05). Subjective analysis confirmed best image quality in MBIR, followed by DLID and HIR, both being superior to FBP (p < 0.05). Diagnostic accuracy for urinary stone detection was best using MBIR (0.94), lowest using FBP (0.84) and comparable between DLID (0.90) and HIR (0.90). Stone size measurements were consistent between all reconstructions and showed excellent correlation (r2 = 0.958-0.975). In conclusion, MBIR yielded the highest image quality and diagnostic accuracy, with DLID producing better results than HIR and FBP in image quality and matching HIR in diagnostic precision.
Collapse
Affiliation(s)
- Robert Terzis
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - Robert Peter Reimer
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - Christian Nelles
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - Erkan Celik
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - Liliana Caldeira
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - Axel Heidenreich
- Department of Urology, Uro-Oncology, Robot-Assisted and Specialized Urologic Surger, University Hospital Cologne, 50937 Cologne, Germany
| | - Enno Storz
- Department of Urology, Uro-Oncology, Robot-Assisted and Specialized Urologic Surger, University Hospital Cologne, 50937 Cologne, Germany
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - David Zopfs
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| | - Nils Große Hokamp
- Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany (D.M.); (D.Z.)
| |
Collapse
|
5
|
Shehata MA, Saad AM, Kamel S, Stanietzky N, Roman-Colon AM, Morani AC, Elsayes KM, Jensen CT. Deep-learning CT reconstruction in clinical scans of the abdomen: a systematic review and meta-analysis. Abdom Radiol (NY) 2023; 48:2724-2756. [PMID: 37280374 DOI: 10.1007/s00261-023-03966-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/13/2023] [Accepted: 05/16/2023] [Indexed: 06/08/2023]
Abstract
OBJECTIVE To perform a systematic literature review and meta-analysis of the two most common commercially available deep-learning algorithms for CT. METHODS We used PubMed, Scopus, Embase, and Web of Science to conduct systematic searches for studies assessing the most common commercially available deep-learning CT reconstruction algorithms: True Fidelity (TF) and Advanced intelligent Clear-IQ Engine (AiCE) in the abdomen of human participants since only these two algorithms currently have adequate published data for robust systematic analysis. RESULTS Forty-four articles fulfilled inclusion criteria. 32 studies evaluated TF and 12 studies assessed AiCE. DLR algorithms produced images with significantly less noise (22-57.3% less than IR) but preserved a desirable noise texture with increased contrast-to-noise ratios and improved lesion detectability on conventional CT. These improvements with DLR were similarly noted in dual-energy CT which was only assessed for a single vendor. Reported radiation reduction potential was 35.1-78.5%. Nine studies assessed observer performance with the two dedicated liver lesion studies being performed on the same vendor reconstruction (TF). These two studies indicate preserved low contrast liver lesion detection (> 5 mm) at CTDIvol 6.8 mGy (BMI 23.5 kg/m2) to 12.2 mGy (BMI 29 kg/m2). If smaller lesion detection and improved lesion characterization is needed, a CTDIvol of 13.6-34.9 mGy is needed in a normal weight to obese population. Mild signal loss and blurring have been reported at high DLR reconstruction strengths. CONCLUSION Deep learning reconstructions significantly improve image quality in CT of the abdomen. Assessment of other dose levels and clinical indications is needed. Careful choice of radiation dose levels is necessary, particularly for small liver lesion assessment.
Collapse
Affiliation(s)
- Mostafa A Shehata
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | | | - Serageldin Kamel
- Department of Lymphoma and Myeloma, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | - Nir Stanietzky
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | | | - Ajaykumar C Morani
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | - Khaled M Elsayes
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | - Corey T Jensen
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA.
| |
Collapse
|
6
|
Lell M, Kachelrieß M. Computed Tomography 2.0: New Detector Technology, AI, and Other Developments. Invest Radiol 2023; 58:587-601. [PMID: 37378467 PMCID: PMC10332658 DOI: 10.1097/rli.0000000000000995] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/04/2023] [Indexed: 06/29/2023]
Abstract
ABSTRACT Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.
Collapse
|
7
|
Editorial Comment: More Evidence Supporting Deep Learning Reconstructions in Abdominal CT-What Should We Do? AJR Am J Roentgenol 2023; 220:296. [PMID: 36169549 DOI: 10.2214/ajr.22.28554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
8
|
Zhang X, Zhang G, Xu L, Bai X, Zhang J, Xu M, Yan J, Zhang D, Jin Z, Sun H. Application of deep learning reconstruction of ultra-low-dose abdominal CT in the diagnosis of renal calculi. Insights Imaging 2022; 13:163. [PMID: 36209195 DOI: 10.1186/s13244-022-01300-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Accepted: 09/16/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Renal calculi are a common and recurrent urological disease and are usually detected by CT. In this study, we evaluated the diagnostic capability, image quality, and radiation dose of abdominal ultra-low-dose CT (ULDCT) with deep learning reconstruction (DLR) for detecting renal calculi. METHODS Sixty patients with suspected renal calculi were prospectively enrolled. Low-dose CT (LDCT) images were reconstructed with hybrid iterative reconstruction (LD-HIR) and was regarded as the standard for stone and lesion detection. ULDCT images were reconstructed with HIR (ULD-HIR) and DLR (ULD-DLR). We then compared stone detection rate, abdominal lesion detection rate, image quality and radiation dose between LDCT and ULDCT. RESULTS A total of 130 calculi were observed on LD-HIR images. Stone detection rates of ULD-HIR and ULD-DLR images were 93.1% (121/130) and 95.4% (124/130). A total of 129 lesions were detected on the LD-HIR images. The lesion detection rate on ULD-DLR images was 92.2%, with 10 cysts < 5 mm in diameter missed. The CT values of organs on ULD-DLR were similar to those on LD-HIR and lower than those on ULD-HIR. Signal-to-noise ratio was highest and noise lowest on ULD-DLR. The subjective image quality of ULD-DLR was similar to that of LD-HIR and better than that of ULD-HIR. The effective radiation dose of ULDCT (0.64 ± 0.17 mSv) was 77% lower than that of LDCT (2.75 ± 0.50 mSv). CONCLUSION ULDCT combined with DLR could significantly reduce radiation dose while maintaining suitable image quality and stone detection rate in the diagnosis of renal calculi.
Collapse
Affiliation(s)
- Xiaoxiao Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China
| | - Gumuyang Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China
| | - Lili Xu
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China
| | - Xin Bai
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China
| | - Jiahui Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China
| | - Min Xu
- Canon Medical System (China), No.10, Jiuxianqiao North Road, Chaoyang District, Beijing, 100024, China
| | - Jing Yan
- Canon Medical System (China), No.10, Jiuxianqiao North Road, Chaoyang District, Beijing, 100024, China
| | - Daming Zhang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China.
| | - Zhengyu Jin
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China. .,National Center for Quality Control of Radiology, Beijing, China.
| | - Hao Sun
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No.1, Wangfujing Street, Dongcheng District, Beijing, 100730, China. .,National Center for Quality Control of Radiology, Beijing, China.
| |
Collapse
|
9
|
Steuwe A, Valentin B, Bethge OT, Ljimani A, Niegisch G, Antoch G, Aissa J. Influence of a Deep Learning Noise Reduction on the CT Values, Image Noise and Characterization of Kidney and Ureter Stones. Diagnostics (Basel) 2022; 12:diagnostics12071627. [PMID: 35885532 PMCID: PMC9317055 DOI: 10.3390/diagnostics12071627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/20/2022] [Accepted: 07/01/2022] [Indexed: 12/25/2022] Open
Abstract
Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included. All patients had undergone abdominal CT between August 2019 and October 2019. CT-images were reconstructed using the following three methods: filtered back-projection, iterative reconstruction, and PixelShine (DL-software) with both sharp and soft kernels. Stone size, CT attenuation, and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) were evaluated and compared using Bonferroni-corrected Friedman tests. Objective image quality was measured in six regions-of-interest. Stone size ranged between 4.4 × 3.1−4.4 × 3.2 mm (sharp kernel) and 5.1 × 3.8−5.6 × 4.2 mm (soft kernel). Mean attenuation ranged between 704−717 Hounsfield Units (HU) (soft kernel) and 915−1047 HU (sharp kernel). Differences in measured stone sizes were ≤1.3 mm. DL-processed images resulted in significantly higher CNR and SNR values (p < 0.001) by decreasing image noise significantly (p < 0.001). DL-software significantly improved objective image quality while maintaining both correct stone size and CT-attenuation values. Therefore, the clinical impact of stone assessment in denoised image data sets remains unchanged. Through the relevant noise suppression, the software additionally offers the potential to further reduce radiation exposure.
Collapse
Affiliation(s)
- Andrea Steuwe
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
- Correspondence: ; Tel.: +49-(0)-211-81-18897
| | - Birte Valentin
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Oliver T. Bethge
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Günter Niegisch
- Department of Urology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany;
| | - Gerald Antoch
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| | - Joel Aissa
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany; (B.V.); (O.T.B.); (A.L.); (G.A.); (J.A.)
| |
Collapse
|