Zhang H, Xing Y, Wang L, Hu Y, Xu Z, Chen H, Lu J, Yang J, Ding B, Hu W, Zhong J. Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024:10.1007/s10278-024-01232-5. [PMID: 39455541 DOI: 10.1007/s10278-024-01232-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Revised: 08/02/2024] [Accepted: 08/06/2024] [Indexed: 10/28/2024]
Abstract
This study aimed to investigate the potential benefit of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) angiography in visualization of abdominal arteries in comparison to standard-reconstruction (SR) images of virtual monoenergetic images (VMI) at low kiloelectron volt (keV). We prospectively included 47 and 47 participants to undergo contrast-enhanced abdominal CT scans within UHR mode on a PCD-CT system using full-dose (FD) and low-dose (LD) protocols, respectively. The data were reconstructed into six series of images: FD_UHR_Br48, FD_UHR_Bv56, FD_UHR_Bv60, FD_SR_Bv40, LD_UHR_Bv48, and LD_SR_Bv40. The UHR reconstructions were performed with three kernels (Bv48, Bv56, and Bv60) within 0.2 mm. The SR were virtual monoenergetic imaging reconstruction with Bv40 kernel at 40-keV within 1 mm. Each series of axial images were reconstructed into coronal and volume-rendered images. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of seven arteries were measured. Three radiologists assessed the image quality, and visibility of nine arteries on all the images. SNR and CNR values of SR images were significantly higher than those of UHR images (P < 0.001). The SR images have higher ratings in image noise (P < 0.001), but the FD_UHR_Bv56 and FD_UHR_Bv60 images has higher rating in vessel sharpness (P < 0.001). The overall quality was not significantly different among FD_VMI_40keV, LD_VMI_40keV, FD_UHR_Bv48, and LD_UHR_Bv48 images (P > 0.05) but higher than those of FD_UHR_Bv56 and FD_UHR_Bv60 images (P < 0.001). There is no significant difference of nine abdominal arteries among six series of images of axial, coronal and volume-rendered images (P > 0.05). To conclude, 1-mm SR image of VMI at 40-keV is superior to 0.2-mm UHR regardless of which kernel is used to visualize abdominal arteries, while 0.2-mm UHR image using a relatively smooth kernel may allow similar image quality and artery visibility when thinner slice image is warranted.
Collapse
Affiliation(s)
- Huan Zhang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Yue Xing
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China
| | - Lingyun Wang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Yangfan Hu
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China
| | - Zhihan Xu
- Siemens Healthineers, Shanghai, 201318, China
| | - Haoda Chen
- Department of General Surgery, Pancreatic Disease Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Junjie Lu
- Department of Epidemiology and Population Health, Stanford University School of Medicine, Stanford, CA, 94305, USA
| | - Jiarui Yang
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA
| | - Bei Ding
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
| | - Weiguo Hu
- Department of Geriatrics and Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
- Medical Center On Aging of Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
| | - Jingyu Zhong
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
| |
Collapse
|
2
|
Hoeijmakers EJI, Stammen L, Wildberger JE, Eijsvoogel NG, Hersbach JM, Pernot JCJG, Flohr TG, Martens B, Jeukens CRLPN. PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT. Eur J Radiol 2024; 179:111680. [PMID: 39133989 DOI: 10.1016/j.ejrad.2024.111680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Accepted: 08/08/2024] [Indexed: 09/01/2024]
Abstract
OBJECTIVES This study aims to demonstrate reduced iodine contrast media (CM) in routine abdominal CT scans in portal venous phase (PVP) using a photon-counting detector CT (PCD-CT) compared to total body weight (TBW) and kV-adapted CM injection protocols on a state-of-the-art energy-integrating detector CT (EID-CT) while maintaining sufficient image quality (IQ). MATERIALS AND METHODS Consecutive contrast-enhanced abdominal PVP CT scans from an EID-CT (Nov 2022-March 2024) and a PCD-CT (Sep 2023-Dec 2023) were compared. CM parameters (total iodine load (TIL), iodine delivery rate (IDR) and dosing factor (DF)) were reported. An individualized acquisition and CM injection protocol based on TBW and kV was applied for the EID-CT and a TBW adapted CM injection protocol was used for the PCD-CT. Objective IQ was evaluated with mean attenuation (Hounsfield Units, HU), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)). Subjective IQ was assessed via a 5-point Likert scale by 2 expert readers based on diagnostic confidence. RESULTS Based on 91 EID-CT scans and 102 PCD-CT scans a TIL reduction of 20.1 % was observed for PCD-CT. PCD-CT demonstrated significantly higher SNR (9.9 ± 1.7 vs. 9.1 ± 1.8, p < 0.001) and CNR (5.1 ± 1.7 vs. 4.3 ± 1.3, p < 0.001) compared to EID-CT. Subjective IQ assessment showed that all scans had sufficient diagnostic IQ. CONCLUSIONS PCD-CT allows for CM reduction while providing higher SNR and CNR compared to EID-CT, using clinical individualized scan and CM injection protocols.
Collapse
Affiliation(s)
- Eva J I Hoeijmakers
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 50, 6200 MD Maastricht, the Netherlands.
| | - Lion Stammen
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 50, 6200 MD Maastricht, the Netherlands
| | - Joachim E Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 50, 6200 MD Maastricht, the Netherlands
| | - Nienke G Eijsvoogel
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands
| | - Johanna M Hersbach
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands
| | - Joey C J G Pernot
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands
| | - Thomas G Flohr
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands; Siemens Healthineers, Siemensstrasse 1, 91301 Forcheim, Germany
| | - Bibi Martens
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands; GROW-School for Oncology and Reproduction, Maastricht University, Universiteitssingel 40, 6229 ER Maastricht, the Netherlands
| | - Cécile R L P N Jeukens
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, the Netherlands
| |
Collapse
|
3
|
Yamada A. Quantifying image quality: are we approaching the grail? Eur Radiol 2024; 34:4492-4493. [PMID: 38175224 DOI: 10.1007/s00330-023-10563-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 12/11/2023] [Accepted: 12/18/2023] [Indexed: 01/05/2024]
Affiliation(s)
- Akira Yamada
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.
| |
Collapse
|