1
|
Manke H, Fluehs D, Stroth M, Bechrakis NE, Foerster AMH, Albrecht J. Measurements regarding a combined therapy concept for ophthalmic tumors consisting of brachytherapy and x-rays. Biomed Phys Eng Express 2024; 10:045056. [PMID: 38588642 DOI: 10.1088/2057-1976/ad3bbb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 04/08/2024] [Indexed: 04/10/2024]
Abstract
Objective.We present a novel concept to treat ophthalmic tumors which combines brachytherapy and low-energy x-ray therapy. Brachytherapy with106Ru applicators is inadequate for intraocular tumors with a height of 7 mm or more. This results from a steep dose gradient, and it is unfeasible to deliver the required dose at the tumor apex without exceeding the maximum tolerable sclera dose of usually 1000 Gy to 1500 Gy. Other modalities, such as irradiation with charged particles, may be individually contraindicated. A dose boost at the apex provided by a superficial x-ray therapy unit, performed simultaneously with the brachytherapy, results in a more homogeneous dose profile than brachytherapy alone. This avoids damage to organs at risk. The applicator may also serve as a beam stop for x-rays passing through the target volume, which reduces healthy tissue dosage. This study aims to investigate the suitability of the applicator to serve as a beam stop for the x-rays.Approach.A phantom with three detector types comprising a soft x-ray ionization chamber, radiochromic films, and a self-made scintillation detector was constructed to perform dosimetry. Measurements were performed using a conventional x-ray unit for superficial therapy to investigate the uncertainties of the phantom and the ability of the applicator to absorb x-rays. The manufacturer provided a dummy plaque to obtain x-ray dose profiles without noise from106Ru decays.Results.The phantom is generally feasible to obtain dose profiles with three different detector types. The interaction of x-rays with the silver of the applicator leads to an increased dose rate in front of the applicator. The dose rate of the x-rays is reduced by up to 90% behind a106Ru applicator. Therefore, a106Ru applicator can be used as a beam stop in combined x-ray and brachytherapy treatment.
Collapse
Affiliation(s)
- H Manke
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, 44227 Dortmund, Germany
| | - D Fluehs
- Radiation and Tumor Clinic, Essen University Hospital, Hufelandstr. 55, 45147 Essen, Germany
| | - M Stroth
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, 44227 Dortmund, Germany
| | - N E Bechrakis
- Radiation and Tumor Clinic, Essen University Hospital, Hufelandstr. 55, 45147 Essen, Germany
| | - A M H Foerster
- Radiation and Tumor Clinic, Essen University Hospital, Hufelandstr. 55, 45147 Essen, Germany
| | - J Albrecht
- Department of Physics, TU Dortmund University, Otto-Hahn-Str. 4a, 44227 Dortmund, Germany
| |
Collapse
|
2
|
Sreenivasa S, Wösle M, Gager Y, Vordermark D, Grajewski L, Krause L, Ciernik IF. Impact of tumour volume and treatment delay on the outcome after linear accelerator-based fractionated stereotactic radiosurgery of uveal melanoma. Br J Ophthalmol 2024; 108:457-464. [PMID: 36894300 PMCID: PMC10894830 DOI: 10.1136/bjo-2022-322750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 01/19/2023] [Indexed: 03/11/2023]
Abstract
BACKGROUND/AIMS Primary radiation therapy is used to treat malignant uveal melanoma (UM). We report our single-centre experience with fractionated radiosurgery (fSRS) with a linear accelerator (LINAC) after specific adaptation for small target volumes with HybridArc. METHODS From October 2014 to January 2020, 101 patients referred to Dessau City Hospital with unilateral UM underwent fSRS with 50 Gy given in five fractions on five consecutive days. Primary endpoints were local tumour control, globe preservation, metastasis and death. Potential prognostic features were analysed. Kaplan-Meier analysis, Cox proportional hazards model and linear models were used for calculations. RESULTS The median baseline tumour diameter was 10.0 mm (range, 3.0-20.0 mm), median tumour thickness 5.0 mm (range, 0.9-15.5 mm) and median gross tumour volume (GTV) 0.4 cm³ (range, 0.2-2.6 cm³). After a median follow-up of 32.0 months (range, 2.5-76.0 months), 7 patients (6.9%) underwent enucleation: 4 (4.0%) due to local recurrence and 3 (3.0%) due to radiation toxicities, and 6 patients (5.9%) revealed tumour persistence with a GTV exceeding 1.0 cm³. Of 20 patients (19.8%) who died, 8 (7.9%) were tumour-related deaths. Twelve patients (11.9%) suffered from distant metastasis. GTV showed an impact on all endpoints, and treatment delay was associated with reduced odds of eye preservation. CONCLUSION LINAC-based fSRS with static conformal beams combined with dynamic conformal arcs and discrete intensity-modulated radiotherapy results in a high tumour control rate. The tumour volume is the most robust physical prognostic marker for local control and disease progression. Avoiding treatment delay improves outcomes.
Collapse
Affiliation(s)
- Shanthala Sreenivasa
- Department of Radiation Oncology, Städtisches Klinikum Dessau, Brandenburg Medical School Theodor Fontane, Dessau, Germany
| | - Markus Wösle
- Department of Radiation Oncology, Städtisches Klinikum Dessau, Brandenburg Medical School Theodor Fontane, Dessau, Germany
| | - Yann Gager
- Department of Research and Development, PathoNext GmbH, Leipzig, Germany
| | - Dirk Vordermark
- Department of Radiation Oncology, Martin Luther Universität Halle-Wittenberg, Halle (Saale), Germany
| | - Luise Grajewski
- Department of Ophthalmology, Städtisches Klinikum Dessau, Brandenburg Medical School Theodor Fontane, Dessau, Germany
| | - Lothar Krause
- Department of Ophthalmology, Städtisches Klinikum Dessau, Brandenburg Medical School Theodor Fontane, Dessau, Germany
| | - I Frank Ciernik
- Department of Radiation Oncology, Städtisches Klinikum Dessau, Brandenburg Medical School Theodor Fontane, Dessau, Germany
- Department of Radiation Oncology, Martin Luther Universität Halle-Wittenberg, Halle (Saale), Germany
| |
Collapse
|
3
|
Klaassen L, Jaarsma-Coes MG, Verbist BM, Vu TK, Marinkovic M, Rasch CR, Luyten GP, Beenakker JWM. Automatic Three-Dimensional Magnetic Resonance-based measurements of tumour prominence and basal diameter for treatment planning of uveal melanoma. Phys Imaging Radiat Oncol 2022; 24:102-110. [PMID: 36386446 PMCID: PMC9649381 DOI: 10.1016/j.phro.2022.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/31/2022] [Accepted: 11/01/2022] [Indexed: 11/07/2022] Open
Abstract
Background and Purpose Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 patients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to automatic T2 measurements and to manual ultrasound measurements. Results Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Automatic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultrasound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound.
Collapse
Affiliation(s)
- Lisa Klaassen
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiation Oncology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Myriam G. Jaarsma-Coes
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Berit M. Verbist
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Holland Particle Therapy Center, PO Box 110, 2600 AC Delft, the Netherlands
| | - T.H. Khanh Vu
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Marina Marinkovic
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Coen R.N. Rasch
- Leiden University Medical Center, Department of Radiation Oncology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Holland Particle Therapy Center, PO Box 110, 2600 AC Delft, the Netherlands
| | - Gregorius P.M. Luyten
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Jan-Willem M. Beenakker
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiation Oncology, PO Box 9600, 2300 RC Leiden, the Netherlands
| |
Collapse
|
4
|
Guberina M, Sokolenko E, Guberina N, Dalbah S, Pöttgen C, Lübcke W, Indenkämpen F, Lachmuth M, Flühs D, Chen Y, Hoffmann C, Deuschl C, Jabbarli L, Fiorentzis M, Foerster A, Rating P, Ebenau M, Grunewald T, Bechrakis N, Stuschke M. Feasibility, Method and Early Outcome of Image-Guided Volumetric Modulated Arc Radiosurgery Followed by Resection for AJCC Stage IIA–IIIB High-Risk Large Intraocular Melanoma. Cancers (Basel) 2022; 14:cancers14194729. [PMID: 36230660 PMCID: PMC9562629 DOI: 10.3390/cancers14194729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/19/2022] [Accepted: 09/25/2022] [Indexed: 11/28/2022] Open
Abstract
Simple Summary The aim of this trial was to define one optimal contemporary treatment procedure for large intraocular melanoma. Radiosurgery is a highly effective treatment in cancer. In this trial, all consecutive patients with large intraocular melanoma treated with multimodality treatment, comprising 4D image-guided volumetric modulated arc radiosurgery procedure followed by resection, were evaluated. In the short-term follow-up there was no clinical toxicity due to external beam radiation therapy, and no local tumor recurrence. In 98% of the cases, the eye bulb could be maintained with partial residual visual acuity in the mean follow-up of 18 months. The outcome estimates one optimal treatment procedure for high-risk, large intraocular melanoma, with excellent results in the first follow-up. Abstract The main objective of this prospective observational study was the characterization of the feasibility and early outcome of image-guided (IG) volumetric modulated arc (VMAT) radiosurgery (SRS) followed by resection for patients with large intraocular melanoma. Our study included consecutive patients with unfavorable-risk melanoma, enrolled in an ophthalmic oncology center. IG-VMAT-SRS was applied by high-resolution 4D image guidance and monitoring. Current stereotactic technique parameters were evaluated for comparison. Side effects and eye function, based on a 5-point CTC assessment score, were quantified. In patients with tumors located more than 0.7–1 mm apart from the optic nerve, partial to complete volume-sparing of the optic nerve head could be achieved. In 95.5% of this subgroup, the vitality of the optic nerve and vision could be preserved by the multimodality-treatment approach (mean follow-up: 18 months (7.5–36 months)). The advanced technology of stereotactic radiotherapy demonstrated the achievability of steep dose gradients around the high-dose volume, with 4D-IG-VMAT dose application. These results enforce IG-VMAT-SRS followed by resection as one of the major therapeutic options for patients with large intraocular melanoma. The combination of 4D-IG high-precision SRS and resection provides an effective treatment for large intraocular melanoma, with few side effects, and enables an eye bulb and even vision preserving modus operandi.
Collapse
Affiliation(s)
- Maja Guberina
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Hufeland Str. 55, 45147 Essen, Germany
- Correspondence: ; Tel.: +49-201-723-2321
| | - Ekaterina Sokolenko
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Nika Guberina
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Sami Dalbah
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Christoph Pöttgen
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Wolfgang Lübcke
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Frank Indenkämpen
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Manfred Lachmuth
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Dirk Flühs
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Ying Chen
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Christian Hoffmann
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Cornelius Deuschl
- Institute of Diagnostic, Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, 45147 Essen, Germany
| | - Leyla Jabbarli
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Miltiadis Fiorentzis
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Andreas Foerster
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Philipp Rating
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Melanie Ebenau
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Tobias Grunewald
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Nikolaos Bechrakis
- Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
| | - Martin Stuschke
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, University Duisburg-Essen, Hufeland Str. 55, 45147 Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Hufeland Str. 55, 45147 Essen, Germany
| |
Collapse
|
5
|
Turkoglu EB, Rao R, Celik E. Long term outcome of adjuvant photodynamic therapy after cyberknife radiotherapy for choroidal melanoma. Photodiagnosis Photodyn Ther 2022; 38:102840. [PMID: 35367617 DOI: 10.1016/j.pdpdt.2022.102840] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/21/2022] [Accepted: 03/29/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE To report the outcome of photodynamic therapy (PDT) for choroidal melanoma as adjuvant treatment with CyberKnife radiotherapy. DESIGN Retrospective interventional case series. METHODS Standard-fluence PDT using verteporfin. OUTCOME MEASURES Regression of tumor; resolution of subretinal fluid (SRF); change in best-corrected visual acuity (BCVA), and complications of PDT. RESULTS The study included 16 choroidal melanomas (3 pigmented, 4 lightly pigmented, 9 amelanotic) treated with adjuvant PDT after CyberKnife radiotherapy. The mean follow up time was 45.5 months after the initial PDT. 13 patients improved completely with PDT sessions and growth was seen in 3 patients. There was seen completely resolution in SRF in 10 eyes, partial resolution in 3 eyes, and stable in 3 eyes. The mean thickness of tumors was 3.9 mm before PDT and 2.3 mm after PDT. Retina pigment epithelium atrophy in 3 patients and subretinal hemorrhage in 1 patient were seen as complication of PDT. Three patients underwent enucleation for recurrence in the tumor. There was not a higher rate of change in BCVA after PDT (37.5% stable; 25% increase; 37.5% decrease. Poor final visual acuity associated with worse initial visual acuity, proximity of the tumor to the foveola and optic disc, and radiation complications. CONCLUSIONS PDT seems to offer a good option for posterior pole choroidal melanoma as adjuvant therapy in suitable cases. Future prospective studies with larger number of patients and with longer follow-up are needed to further investigation.
Collapse
Affiliation(s)
- Elif Betul Turkoglu
- Ocular Oncology Service, Department of Ophthalmology, Akdeniz University, Antalya, Turkey.
| | - Raksha Rao
- Oculoplasty and Ocular Oncology, Chaithanya Eye Hospital and Research Institute, Trivandrum, India
| | - Erkan Celik
- Retina Service, Department of Ophthalmology, Sakarya University, Sakarya, Turkey
| |
Collapse
|