Schneeberger Y, Sarwari H, Köll B, Demal TJ, Bhadra OD, von der Heide I, Hannen L, Grundmann D, Voigtländer L, Waldschmidt L, Schirmer J, Pecha S, Schofer N, Sörensen N, Blankenberg S, Reichenspurner H, Conradi L, Seiffert M, Schaefer A. Balloon-expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies. Catheter Cardiovasc Interv 2024; 103:194-201. [PMID: 38037296 DOI: 10.1002/ccd.30922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/02/2023] [Accepted: 11/19/2023] [Indexed: 12/02/2023]
Abstract
OBJECTIVES Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.
Collapse
Affiliation(s)
- Yvonne Schneeberger
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Harun Sarwari
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Benedikt Köll
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Till J Demal
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Oliver D Bhadra
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Ina von der Heide
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Laura Hannen
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - David Grundmann
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Lisa Voigtländer
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Lara Waldschmidt
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Johannes Schirmer
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Simon Pecha
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Niklas Schofer
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Nils Sörensen
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Stefan Blankenberg
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Hermann Reichenspurner
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Lenard Conradi
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Moritz Seiffert
- Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany
| | - Andreas Schaefer
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany
| |
Collapse
|
3
|
Nomura T, Miyasaka M, Nakashima M, Saigan M, Inoue A, Enta Y, Toki Y, Ishii K, Sakurai M, Munehisa Y, Ito J, Hata M, Taguri M, Tada N. Delivery balloon volume positively correlates with the diameter and effective orifice area of implanted SAPIEN 3. J Cardiol 2022; 80:190-196. [PMID: 35469714 DOI: 10.1016/j.jjcc.2022.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 03/06/2022] [Accepted: 03/11/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND In transcatheter aortic valve replacement (TAVR) using SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, CA, USA), some clinicians decrease or increase the delivery balloon volume (VOL) when deploying S3 or conducting post-dilatation. However, the effects of controlling VOL on transcatheter heart valve diameter (THVD) and valve function remain unclear. We assessed associations among VOL, THVD, and effective orifice area (EOA) of S3. METHODS We enrolled patients undergoing TAVR using 23- and 26-mm S3 in Sendai Kousei Hospital between 2017 and 2019. VOL was controlled based on preprocedural computed tomography and intraprocedural transesophageal echocardiography (TEE). THVD were defined as the diameters of transcatheter heart valve at mid-level measured by TEE. RESULTS In enrolled 332 patients (23-mm, n = 188; 26-mm, n = 144), one (0.3%) and two (0.6%) developed annulus rupture and moderate/severe paravalvular leak, respectively. VOL at deployment was positively correlated with THVD on deployment (23-mm, r = 0.44, p < 0.001; 26-mm, r = 0.57, p < 0.001) and EOA (23-mm, r = 0.23, p = 0.0019; 26-mm, r = 0.22, p = 0.0094). In multiple regression analyses, VOL and post-dilatation were significant determinants of THVD, although aortic annulus area, calcium volume, and pre-dilatation were not. The areas under the receiver operating characteristic curve that were used to evaluate the accuracy of the index obtained by dividing THVD by body surface area (indexed THVD) to predict patient-prosthesis mismatch (PPM) were 0.744 and 0.811 in the 23- and 26-mm cohorts, respectively. A cut-off indexed THVD of ≤11.5 and 12.1 mm/m2 well predicted PPM (23-mm, odds ratio, 5.20; 95% confidence interval, 1.33-20.3; 26-mm, odds ratio 14.1, 95% confidence interval 2.40-81.0). CONCLUSION VOL was positively correlated with THVD and EOA. Smaller indexed THVD was associated with a higher incidence of PPM. Controlling VOL under on-site THVD evaluation may be useful in reducing the PPM incidence.
Collapse
Affiliation(s)
- Takehiro Nomura
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan; Department of Cardiovascular Surgery, School of Medicine, Dokkyo Medical University, Shimotsuga-gun, Tochigi, Japan.
| | - Masaki Miyasaka
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan; Department of Laboratory Medicine, Jikei University School of Medicine, Tokyo, Japan
| | - Masaki Nakashima
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Makoto Saigan
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Arata Inoue
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Yusuke Enta
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Yusuke Toki
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Kazunori Ishii
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Mie Sakurai
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Yoshiko Munehisa
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Jun Ito
- Department of Anesthesiology, Sendai Kousei Hospital, Sendai, Japan
| | - Masaki Hata
- Department of Cardiovascular Surgery, Sendai Kousei Hospital, Sendai, Miyagi, Japan
| | - Masataka Taguri
- Department of Biostatistics and Epidemiology, Yokohama City University, Yokohama, Kanagawa, Japan
| | - Norio Tada
- Department of Cardiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan; Department of Cardiovascular Surgery, School of Medicine, Dokkyo Medical University, Shimotsuga-gun, Tochigi, Japan
| |
Collapse
|
4
|
Toba T, Kawamori H, Otake H, Hirata KI. Successful percutaneous balloon aortic valvuloplasty for worsening paravalvular leakage detected one week after the balloon expandable transcatheter aortic valve replacement. Cardiovasc Interv Ther 2021; 37:417-419. [PMID: 34086267 DOI: 10.1007/s12928-021-00787-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 05/31/2021] [Indexed: 10/21/2022]
Affiliation(s)
- Takayoshi Toba
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 6500017, Japan.
| | - Hiroyuki Kawamori
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 6500017, Japan
| | - Hiromasa Otake
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 6500017, Japan
| | - Ken-Ichi Hirata
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 6500017, Japan
| |
Collapse
|