Bastiaansen WAP, Klein S, Koning AHJ, Niessen WJ, Steegers-Theunissen RPM, Rousian M. Computational methods for the analysis of early-pregnancy brain ultrasonography: a systematic review.
EBioMedicine 2023;
89:104466. [PMID:
36796233 PMCID:
PMC9958260 DOI:
10.1016/j.ebiom.2023.104466]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/09/2023] [Accepted: 01/23/2023] [Indexed: 02/16/2023] Open
Abstract
BACKGROUND
Early screening of the brain is becoming routine clinical practice. Currently, this screening is performed by manual measurements and visual analysis, which is time-consuming and prone to errors. Computational methods may support this screening. Hence, the aim of this systematic review is to gain insight into future research directions needed to bring automated early-pregnancy ultrasound analysis of the human brain to clinical practice.
METHODS
We searched PubMed (Medline ALL Ovid), EMBASE, Web of Science Core Collection, Cochrane Central Register of Controlled Trials, and Google Scholar, from inception until June 2022. This study is registered in PROSPERO at CRD42020189888. Studies about computational methods for the analysis of human brain ultrasonography acquired before the 20th week of pregnancy were included. The key reported attributes were: level of automation, learning-based or not, the usage of clinical routine data depicting normal and abnormal brain development, public sharing of program source code and data, and analysis of the confounding factors.
FINDINGS
Our search identified 2575 studies, of which 55 were included. 76% used an automatic method, 62% a learning-based method, 45% used clinical routine data and in addition, for 13% the data depicted abnormal development. None of the studies shared publicly the program source code and only two studies shared the data. Finally, 35% did not analyse the influence of confounding factors.
INTERPRETATION
Our review showed an interest in automatic, learning-based methods. To bring these methods to clinical practice we recommend that studies: use routine clinical data depicting both normal and abnormal development, make their dataset and program source code publicly available, and be attentive to the influence of confounding factors. Introduction of automated computational methods for early-pregnancy brain ultrasonography will save valuable time during screening, and ultimately lead to better detection, treatment and prevention of neuro-developmental disorders.
FUNDING
The Erasmus MC Medical Research Advisor Committee (grant number: FB 379283).
Collapse