1
|
Steinbrück I, Faiss S, Dumoulin FL, Oyama T, Pohl J, von Hahn T, Schmidt A, Allgaier HP. Predictive Factors for the Outcome of Unsupervised Endoscopic Submucosal Dissection During the Initial Learning Curve with Prevalence-Based Indication. Dig Dis Sci 2023; 68:3614-3624. [PMID: 37421512 DOI: 10.1007/s10620-023-08026-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 06/26/2023] [Indexed: 07/10/2023]
Abstract
BACKGROUND For an adequate educational strategy of ESD in non-Asian settings with prevalence-based indication it is essential to define adequate lesions, suitable for the beginner without on-site expert-supervision. AIMS We analyzed possible predictors for outcome parameters of effectiveness and safety during the initial learning curve. METHODS The first 120 ESDs of four operators (n = 480), performed between 2007 and 2020 in four tertiary hospitals, were enrolled. Uni-/multivariable regression analysis was done with sex, age, pretreated lesion, lesion size, organ, and organ-based localization as possible independent predictors for en bloc resection (EBR), complication, and resection speed. RESULTS Rates of EBR, complication, and resection speed were 84.5%, 14.2%, and 6.20 (± 4.45) cm2/h. Independent predictors for EBR were pretreated lesion (OR 0.27 [0.13-0.57], p < 0.001) and non-colonic ESD (OR 2.29 [1.26-4.17] (rectum)/5.72 [2.36-13.89] (stomach)/7.80 [2.60-23.42] (esophagus), p < 0.001), for complication pretreated lesion (OR 3.04 [1.46-6.34], p < 0.001) and lesion size (OR 1.02 [1.004-1.04], p = 0.012) and for resection speed pretreated lesion (RC - 3.10 [- 4.39 to - 1.81], p < 0.001), lesion size (RC 0.13 [0.11-0.16], p < 0.001) and male patient (RC - 1.11 [- 1.85 to - 0.37], p < 0.001). We found no significant difference in the incidence of technically unsuccessful resections in esophageal (1/84), gastric (3/113), rectal (7/181), and colonic (3/101) ESDs (p = 0.76). Technical failure was mainly caused by complication and fibrosis/pretreatment. CONCLUSION During the initial learning curve of an unsupervised ESD program with prevalence-based indication, pretreated lesions and colonic ESDs should be avoided. In contrast, lesion size and organ-based localizations have less predictive value for the outcome.
Collapse
Affiliation(s)
- Ingo Steinbrück
- Department of Medicine and Gastroenterology, Evangelisches Diakoniekrankenhaus Freiburg, Academic Teaching Hospital of University of Freiburg, Wirthstraße 11, 79110, Freiburg, Germany.
| | - Siegbert Faiss
- Department of Gastroenterology, Sana Klinikum Lichtenberg, Academic Teaching Hospital of University of Berlin, Fanningerstraße 32, 10365, Berlin, Germany
| | - Franz Ludwig Dumoulin
- Department of Medicine and Gastroenterology, Gemeinschaftskrankenhaus Bonn, Academic teaching Hospital of University of Bonn, Prinz-Albert-Straße 40, 53113, Bonn, Germany
| | - Tsuneo Oyama
- Department of Endoscopy, Saku Central Hospital Advanced Care Center, 3400-28 Nakagomi, Saku, Nagano, 3850051, Japan
| | - Jürgen Pohl
- Department of Gastroenterology, Asklepios Klinik Altona, Academic Teaching Hospital of University of Hamburg, Paul-Ehrlich-Straße 1, 22763, Hamburg, Germany
| | - Thomas von Hahn
- Department of Gastroenterology, Hepatology and Endoscopy, Asklepios Klinik Barmbek, Academic Teaching Hospital of University of Hamburg, Rübenkamp 220, 22307, Hamburg, Germany
| | - Arthur Schmidt
- Department of Medicine II, Medical Center, University of Freiburg, Faculty of Medicine, Hugstetter Straße 55, 79106, Freiburg, Germany
| | - Hans-Peter Allgaier
- Department of Medicine and Gastroenterology, Evangelisches Diakoniekrankenhaus Freiburg, Academic Teaching Hospital of University of Freiburg, Wirthstraße 11, 79110, Freiburg, Germany
| |
Collapse
|
2
|
Masunaga T, Kato M, Sasaki M, Iwata K, Miyazaki K, Kubosawa Y, Mizutani M, Takatori Y, Matsuura N, Nakayama A, Takabayashi K, Yahagi N. Effectiveness of water pressure method in colorectal endoscopic submucosal dissection by novice endoscopists. Endosc Int Open 2023; 11:E641-E648. [PMID: 37502676 PMCID: PMC10370489 DOI: 10.1055/a-2102-7578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 05/25/2023] [Indexed: 07/29/2023] Open
Abstract
Background and study aims Colorectal endoscopic submucosal dissection (ESD) remains challenging for novice endoscopists. Not only the underwater conditions but also active use of water pressure with the water pressure method (WPM) can help widen the submucosal layer. This study aimed to clarify the usefulness of WPM in colorectal ESD, especially for novice endoscopists. Methods This study was ex vivo and enrolled three novices. Each endoscopist performed conventional ESD (C-ESD) and ESD with WPM (WPM-ESD) 10 times on an excised bovine rectum. The treatment outcomes were compared between the two groups. Results Median procedure time was significantly shorter in the WPM-ESD group than in the C-ESD group (54 minutes, interquartile range [IQR] 42-67 vs. 45 minutes, IQR 34-55, P = 0.035). Although no significant difference in the activation time of electrical surgical unit (ESU) during the procedure was noted, the interval time during the procedure at which the ESU was not activated was significantly shorter in the WPM-ESD group (52 minutes, IQR 40-65 vs. 42 minutes, IQR 32-52, P = 0.030) than in the C-ESD group. Moreover, the time required for the endoscope to enter the submucosa was significantly shorter in the WPM-ESD group than in the C-ESD group (8.0 minutes, IQR 6.0-10 vs. 5.0 minutes, IQR 3.0-6.0, P < 0.001). Conclusions The present study reveals that the WPM method significantly shortens the procedure times for novices in colorectal ESD, especially the interval time, which refers to the time spent creating the field of view, and the time required for the endoscope to enter the submucosa.
Collapse
Affiliation(s)
- Teppei Masunaga
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Motohiko Kato
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Motoki Sasaki
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Kentaro Iwata
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Kurato Miyazaki
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Yoko Kubosawa
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Mari Mizutani
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Yusaku Takatori
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Noriko Matsuura
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Atsushi Nakayama
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Kaoru Takabayashi
- Center for Diagnostic and Therapeutic Endoscopy, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| | - Naohisa Yahagi
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
3
|
Simsek C, Aihara H. Training in Endoscopic Submucosal Dissection in the United States: The Current Paradigm. Gastrointest Endosc Clin N Am 2023; 33:41-53. [PMID: 36375885 DOI: 10.1016/j.giec.2022.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Endoscopic submucosal dissection (ESD) training in Japan is pursued through a designated master-apprentice, organ-based stepwise training model. However, applying a similar program to the United States is not a practical strategy due to the significant differences in the training system and disease prevalence. To incorporate the ESD training into the current advanced endoscopy fellowship program, the use of recently developed techniques and technologies to improve the efficiency of ESD is ideal. The ESD training program in the United States should be prevalence-based, with increased involvement of trainees depending on their objectively assessed competency levels.
Collapse
Affiliation(s)
- Cem Simsek
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Hiroyuki Aihara
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
4
|
Learning curve of endoscopic submucosal dissection (ESD) with prevalence-based indication in unsupervised Western settings: a retrospective multicenter analysis. Surg Endosc 2022; 37:2574-2586. [PMID: 36344898 DOI: 10.1007/s00464-022-09742-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 10/14/2022] [Indexed: 11/09/2022]
Abstract
BACKGROUND AND AIMS As there is still no consensus about the adequate training strategy for ESD in Western countries, we evaluated unsupervised prevalence-based learning curves including detailed organ-specific subgroup analysis. METHODS The first 120 ESDs of four operators (n = 480) were divided into three groups (1: ESD 1-40, 2: ESD 41-80, 3: ESD 81-120). Outcome parameters were rates of technical success, en bloc and R0 resection, the resection speed, rates of conversion to EMR, curative resection, adverse events, surgery due to adverse events, and recurrence. In addition, we analyzed the achievement of quality benchmarks indicating levels of expertise. RESULTS After exclusion of pretreated lesions, 438 procedures were enrolled in the final analysis. Technical success rates were > 96% with significant improvements regarding rate of en bloc resection (from 82.6 to 91.2%), resection speed (from 4.54 to 7.63 cm2/h), and rate of conversion to EMR (from 22.0 to 8.1%). No significant differences could be observed for rates of R0 resection (65.9 vs. 69.6%), curative resection (55.8 vs. 55.7%), adverse events (16.3 vs. 11.7%), surgery due to adverse events (1.5 vs. 1.3%), and recurrence (12.5 vs. 4.5%). Subgroup and benchmark analysis revealed an improvement in esophageal, gastric, and rectal ESD with achievement of competence levels for the esophagus and stomach within 80 and most of the benchmarks for proficiency level within 120 procedures. Some of the benchmarks could also be achieved in rectal ESD. CONCLUSIONS This trial confirms safety and feasibility of unsupervised ESD along the initial learning curve with prevalence-based indication and exclusion of colonic cases.
Collapse
|
5
|
Mitsuyoshi Y, Ide D, Ohya TR, Ishihoka M, Yasue C, Chino A, Igarashi M, Nakashima A, Saito S, Fujisaki J, Saruta M. Training program using a traction device improves trainees' learning curve of colorectal endoscopic submucosal dissection. Surg Endosc 2022; 36:4462-4469. [PMID: 34704150 DOI: 10.1007/s00464-021-08799-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 10/17/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND Colorectal endoscopic submucosal dissection (ESD) requires advanced endoscopic skill. For safer and more reliable ESD implementation, various traction devices have been developed in recent years. The purpose of this research was to evaluate whether an ESD training program using a traction device (TD) would contribute to the improvement of trainees' skill acquisition. METHODS The differences in treatment outcomes and learning curves by the training program were compared before and after the introduction of TD (control group: January 2014 to March 2016; TD group: April 2016 to June 2018). RESULTS A total of 316 patients were included in the analysis (TD group: 202 cases; control group: 114 cases). The number of cases required to achieve proficiency in ESD techniques was 10 in the TD group and 21 in the control group. Compared to the control group, the TD group had a significant advantage in ESD self-completion rate (73.8% vs. 58.8%), dissection speed (19.5 mm2/min vs. 15.9 mm2/min), en bloc resection rate (100% vs. 90%), and R0 resection rate (96% vs. 83%). CONCLUSIONS The rate of colorectal ESD self-completion by trainees improved immediately after the start of the training program using a traction device compared to the conventional method, and the dissection speed tended to increase linearly with ESD experience. We believe that ESD training using a traction device will help ESD techniques to be performed safely and reliably among trainees.
Collapse
Affiliation(s)
- Yuki Mitsuyoshi
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Daisuke Ide
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan.
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan.
| | | | - Mitsuaki Ishihoka
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
| | - Chihiro Yasue
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
| | - Akiko Chino
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
| | - Masahiro Igarashi
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
| | - Akio Nakashima
- Division of Nephrology and Hypertension, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Shoichi Saito
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
| | - Junko Fujisaki
- Department of Gastroenterology, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31, Ariake, Koto, Tokyo, 135-8550, Japan
| | - Masayuki Saruta
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
6
|
Miyakawa A, Kuwai T, Sakuma Y, Kubota M, Nakamura A, Itobayashi E, Shimura H, Suzuki Y, Shimura K. Learning curve for endoscopic submucosal dissection of early colorectal neoplasms with a monopolar scissor-type knife: use of the cumulative sum method. Scand J Gastroenterol 2020; 55:1234-1242. [PMID: 32853052 DOI: 10.1080/00365521.2020.1807597] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Although scissor-type knives such as the Stag-Beetle (SB) Knife Jr are expected to result in a safe and easy colorectal endoscopic submucosal dissection (CR-ESD), information regarding the learning curve is lacking. Therefore, this study evaluated the learning curve with using SB Knife Jr. MATERIALS AND METHODS We retrospectively reviewed 507 CR-ESD procedures performed in 464 patients using SB Knife Jr. The primary endpoint was a learning curve to achieve a satisfactory complete resection rate. The secondary endpoints were learning curves to achieve a satisfactory en bloc resection rate, curative resection rate, and resection speed. RESULTS The complete, en bloc, and curative resection rates were 91.9%, 95.9%, and 84.0%, respectively. Moving average analysis showed that 39 cases were required for a complete resection rate of >80%, 41 for an en bloc resection rate of >90%, and 50 for a curative resection rate of >75%. We divided the procedure into three phases using the cumulative sum method: I, II, and III (cases 1-36, 37-119, and 120-507, respectively). Although we found no significant between-phase differences, the complete resection rate showed an increasing trend in Phase III (83.3 vs. 89.2 vs. 93.3%; p = .099). The en bloc resection rate (91.7 vs. 91.6 vs. 97.2%; p = .047) and resection speed (20.5 vs. 7.2 vs. 6.8 min/cm2; p < .001) were greater in Phase III. Despite the larger specimen size (27.3 vs. 38.2 vs. 40.4 mm; p < .001) and more severe fibrosis (p < .001) in Phase III, the procedure time was shorter (73.8 vs. 57.8 vs. 54.2 min; p = .041). The curative resection rate was not significantly different between phases. CONCLUSIONS SB Knife Jr enables safe and easy CR-ESD during the introductory period compared to the conventional tip-type knife and has an acceptable learning curve. Therefore, using this knife will encourage the widespread adoption of CR-ESD in Asian general hospitals and non-Asian countries.
Collapse
Affiliation(s)
- Akihiro Miyakawa
- Department of Gastroenterology, Asahi General Hospital, Asahi, Japan
| | - Toshio Kuwai
- Department of Gastroenterology, National Hospital Organization Kure Medical Center and Chugoku Cancer Center, Kure, Japan
| | - Yukie Sakuma
- Clinical Research Center, Asahi General Hospital, Asahi, Japan
| | - Manabu Kubota
- Department of Gastroenterology, Asahi General Hospital, Asahi, Japan
| | - Akira Nakamura
- Department of Gastroenterology, Asahi General Hospital, Asahi, Japan
| | - Ei Itobayashi
- Department of Gastroenterology, Asahi General Hospital, Asahi, Japan
| | - Haruhisa Shimura
- Department of Gastroenterology, Asahi General Hospital, Asahi, Japan
| | - Yoshio Suzuki
- Department of Pathology, Asahi General Hospital, Asahi, Japan
| | - Kenji Shimura
- Department of Gastroenterology, Asahi General Hospital, Asahi, Japan
| |
Collapse
|
7
|
Rajendran A, Pannick S, Thomas-Gibson S, Oke S, Anele C, Sevdalis N, Haycock A. Systematic literature review of learning curves for colorectal polyp resection techniques in lower gastrointestinal endoscopy. Colorectal Dis 2020; 22:1085-1100. [PMID: 31925890 DOI: 10.1111/codi.14960] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Accepted: 11/26/2019] [Indexed: 02/08/2023]
Abstract
AIM The performance of therapeutic procedures in lower gastrointestinal endoscopy (LGI) can be challenging and carries an increased risk of adverse events. There is increasing demand for the training of endoscopists in these procedures, but limited guidelines exist concerning procedural competency. The aim of this study was to assess the learning curves for LGI polypectomy, colorectal endoscopic mucosal resection (EMR) and colorectal endoscopic submucosal dissection (ESD). METHOD A systematic review of electronic databases between 1946 and September 2019 was performed. Citations were included if they reported learning curve data. Outcome measures that defined the success of procedural competency were also recorded. RESULTS A total of 34 out of 598 studies met the inclusion criteria of which 28 were related to ESD, three to polypectomy and three to EMR. Outcome measures for polypectomy competency (en bloc resection, delayed bleeding and independent polypectomy rate) were achieved after completion of between 250 and 400 polypectomies and after 300 colonoscopies. EMR outcome measures, including complete resection and recurrence, were achieved variably between 50 and 300 procedures. Outcome measures for ESD included efficiency (resection rates and procedural speed) and safety (adverse events). En bloc resection rates of over 80% and R0 resection rates of over 70% were achieved at 20-40 cases and procedural speed increased after 30 ESD cases. Competency in safety metrics was variably achieved at 20-200 cases. CONCLUSION There is a paucity of data on learning curves in LGI polypectomy, EMR and ESD. Despite limited evidence, we have identified relevant outcome measures and threshold numbers for the most common LGI polyp resection techniques for potential inclusion in training programmes/credentialing guidelines.
Collapse
Affiliation(s)
- A Rajendran
- The Wolfson Unit for Endoscopy, St Mark's Hospital, Harrow, UK.,Centre for Implementation Science, Health Service and Population Research Department, King's College London, London, UK.,Hillingdon Hospitals NHS Foundation Trust, Uxbridge, UK
| | - S Pannick
- Department of Surgery and Cancer, Imperial College, London, UK
| | - S Thomas-Gibson
- The Wolfson Unit for Endoscopy, St Mark's Hospital, Harrow, UK.,Department of Surgery and Cancer, Imperial College, London, UK
| | - S Oke
- Hillingdon Hospitals NHS Foundation Trust, Uxbridge, UK.,Department of Surgery and Cancer, Imperial College, London, UK
| | - C Anele
- Department of Surgery and Cancer, Imperial College, London, UK
| | - N Sevdalis
- Centre for Implementation Science, Health Service and Population Research Department, King's College London, London, UK
| | - A Haycock
- The Wolfson Unit for Endoscopy, St Mark's Hospital, Harrow, UK.,Department of Surgery and Cancer, Imperial College, London, UK
| |
Collapse
|
8
|
McCarty TR, Aihara H. Current state of education and training for endoscopic submucosal dissection: Translating strategy and success to the USA. Dig Endosc 2020; 32:851-860. [PMID: 31797470 DOI: 10.1111/den.13591] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Accepted: 12/02/2019] [Indexed: 02/08/2023]
Abstract
Endoscopic submucosal dissection (ESD) is a rigorous and technically sophisticated method for removal of lesions within the gastrointestinal tract. Despite having advantages of en-bloc resection of lesions, regardless of size, and widespread use in Japan and Asia, ESD has not become widely adopted in the USA for a variety of reasons. Based upon Japanese education and the master-apprentice model, modification to the education system and additional techniques designed to facilitate broader adoption are required for trainees in the USA. This article will review the current state of education and training for ESD in the USA.
Collapse
Affiliation(s)
- Thomas R McCarty
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, USA
| | - Hiroyuki Aihara
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, USA
| |
Collapse
|
9
|
Review on colorectal endoscopic submucosal dissection focusing on the technical aspect. Surg Endosc 2020; 34:3766-3787. [PMID: 32342217 DOI: 10.1007/s00464-020-07599-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Accepted: 04/23/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND Endoscopic submucosal dissection (ESD) enables removal of broad-based colorectal polyps or lateral spreading tumors with a higher rate of en bloc resection and a lower risk of local recurrence. However, it is technically demanding. Over the past 20 years, various equipment and innovative techniques have been developed to reduce the difficulty of ESD. The information in the literature is scattered. Our aim is to provide a comprehensive review on the setup and technical aspects of colorectal ESD. METHODS We searched the PubMed database and systemically reviewed all original and review articles related to colorectal ESD. Further manual search according to reference lists of identified articles were done. The selected articles were categorized and reviewed. Original figures were created to help readers understand some of the ESD techniques. RESULTS A total of 216 articles were identified, in which 25 of them were review articles and 191 of them were original articles. They were categorized and reviewed. An in-depth appraisal of the setting, equipment, and technical aspects of colorectal ESD was performed. CONCLUSIONS Although ESD is a technically demanding procedure that requires expert endoscopic skills, it can be mastered. With good peri-procedural preparation, sufficient knowledge of the equipment, and thorough understanding of the useful endoscopic tricks and maneuvers, colorectal ESD can be performed smoothly and safely.
Collapse
|
10
|
Ide D, Saito S, Ohya TR, Nishikawa Y, Horie Y, Yasue C, Chino A, Igarashi M, Saruta M, Fujisaki J. Colorectal endoscopic submucosal dissection can be efficiently performed by a trainee with use of a simple traction device and expert supervision. Endosc Int Open 2019; 7:E824-E832. [PMID: 31198847 PMCID: PMC6561769 DOI: 10.1055/a-0901-7113] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Accepted: 02/26/2019] [Indexed: 02/07/2023] Open
Abstract
Background and study aims Colorectal endoscopic submucosal dissection (ESD) is technically challenging owing to submucosal fibrosis and difficult endoscope manipulation. Therefore, various traction methods have been reported. We often use a simple looped nylon thread attached to a clip to assist with dissection. We assessed the feasibility of mentor-guided colorectal ESD using this traction device (TD). Patients and methods From December 2017 to March 2018, we retrospectively reviewed outcomes of 101 colorectal ESDs performed by two groups of endoscopists (A, 5 endoscopists with colorectal ESD experience of < 50 cases; B, 5 endoscopists with experience of > 300 cases). Group A was further divided into two subgroups that performed ESD with or without TD. Results No significant difference was observed in ESD completion rates (86.1 % [62/72] vs. 96.6 % [28/29]; odds ratio [OR], 0.22; 95 % confidence interval [CI], 0.005 - 1.71; P = 0.17) or procedure times (52.0 min vs. 40.0 min; P = 0.27) and adverse event rates between groups A and B. The rate of TD use was significantly higher in group A than in group B (44.4 % [32/72] vs. 20.7 % [6/29]; OR, 3.03; CI, 1.04 - 10.23; P = 0.03). The completion rate was not different between the two subgroups of group A (with vs. without TD) (81.2 % [26/32] vs. 90.0 % [36/40]; OR, 0.49; CI, 0.09 - 2.29; P = 0.32); however, the proportion of fibrosis cases was significantly higher in the TD-use group (46.8 % [15/32] vs. 22.5 % [9/40]; OR, 2.99; CI, 0.98 - 9.59; P = 0.03). Conclusion Mentor-guided colorectal ESD using TD was performed efficiently, safely, and in a manner comparable to that of experts.
Collapse
Affiliation(s)
- Daisuke Ide
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan,Department of Internal Medicine, Division of Gastroenterology and Hepatology, The Jikei University School of Medicine, Tokyo, Japan,Corresponding author Daisuke Ide, MD, PhD Department of Lower Gastrointestinal MedicineThe Cancer Institute Hospital of Japanese Foundation for Cancer Research3-8-31, Ariake, KotoTokyo 135-8550Japan+81-3-3520-0141
| | - Shoichi Saito
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | | | - Yuske Nishikawa
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Yoshimasa Horie
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Chihiro Yasue
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Akiko Chino
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Masahiro Igarashi
- Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Masayuki Saruta
- Department of Internal Medicine, Division of Gastroenterology and Hepatology, The Jikei University School of Medicine, Tokyo, Japan
| | - Junko Fujisaki
- Department of Upper Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| |
Collapse
|
11
|
Cost Analysis of Endoscopic Submucosal Dissection for the Treatment of Colorectal Lesions in China. BIOMED RESEARCH INTERNATIONAL 2019; 2019:6983896. [PMID: 31032359 PMCID: PMC6457293 DOI: 10.1155/2019/6983896] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Revised: 02/25/2019] [Accepted: 03/05/2019] [Indexed: 12/19/2022]
Abstract
Aim The aim of the study was to evaluate costs associated with colonic endoscopic submucosal dissection (ESD) for treatment of colorectal cancer. Methods The study is a retrospective analysis of data on 395 patients treated by colonic ESD. Results The operation, consumable items, and medication accounted for 71% of the total costs for colonic ESD treatment. Medication and consumable items' costs were higher if lesions occurred in the transverse colon and right hemicolon compared to the left hemicolon. Medication, consumable items, and total costs were higher for larger lesions. Lesion numbers and carcinoma were associated with higher medication, consumable items, operation, and total costs. Positive surgical margins and complications of hemorrhage or perforation were positively correlated with higher costs for medication, consumable items, and total costs. Conclusion Labor costs for doctors and nurses remain low in China. Costs for medication and consumable items were higher for treatment involving the transverse colon or right hemicolon (vs. the left hemicolon), larger lesions, carcinoma, and a positive surgical margin. A benchmark cost estimate for ESD treatment including 4 days of postoperative hospitalization was determined to be approximately 5400 USD.
Collapse
|
12
|
Tanaka H, Oka S, Tanaka S, Inagaki K, Okamoto Y, Matsumoto K, Boda K, Yamashita K, Sumimoto K, Ninomiya Y, Hayashi N, Chayama K. The utility of a novel colonoscope with retroflexion for colorectal endoscopic submucosal dissection. Endosc Int Open 2019; 7:E130-E137. [PMID: 30705943 PMCID: PMC6336463 DOI: 10.1055/a-0810-0567] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Accepted: 11/21/2018] [Indexed: 02/08/2023] Open
Abstract
Background and study aims The PCF-H290TI/L produced by Olympus is a novel colonoscope equipped with some advantageous features for endoscopic treatment. It is expected to improve the potential for retroflexion and overall endoscope operability, which can reduce the difficulty of performing colorectal ESD. The aim of this study was to evaluate the utility of the novel colonoscope in colorectal ESD. Methods Three hundred and forty-eight consecutive colorectal lesions resected via ESD between June 2014 and January 2017 at Hiroshima University Hospital were included in the retroflexion ability analysis. We compared the retroflexion potential of PCF-H290TI to that of a conventional endoscope. Two hundred and twenty-seven colorectal lesions located in the left-sided colon and resected with ESD between April 2009 and February 2018 were enrolled in the treatment outcome analysis. Treatment outcomes using PCF-H290TI compared to those of the conventional colonoscope, and outcomes of the PCF-H290TI with retroflexion compared to those of the conventional colonoscope without retroflexion were evaluated by propensity score matching. Results The retroflexion rate with the PCF-H290TI was 76 %, which was significantly higher than the 44 % rate with the conventional scope. Endoscope operability was better and dissection speed was faster when using the PCF-H290TI with retroflexion compared to the conventional colonoscope without retroflexion. There were no significant differences between the groups in en bloc resection rate and adverse events. Conclusion Compared to the conventional colonoscope, the PCF-H290TI/L made it easier to perform ESD via a retrograde approach regardless of tumor location, and thus may be useful for performing colorectal ESD.
Collapse
Affiliation(s)
- Hidenori Tanaka
- Department of Endoscopy, Hiroshima University Hospital, Hiroshima, Japan
| | - Shiro Oka
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan,Corresponding author: Shiro Oka Department of Gastroenterology and MetabolismHiroshima University Hospital1-2-3, Kasumi, MinamikuHiroshima 734-8551Japan+81-82-257-5939
| | - Shinji Tanaka
- Department of Endoscopy, Hiroshima University Hospital, Hiroshima, Japan
| | - Katsuaki Inagaki
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Yuki Okamoto
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Kenta Matsumoto
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Kazuki Boda
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Ken Yamashita
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Kyoku Sumimoto
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| | - Yuki Ninomiya
- Department of Endoscopy, Hiroshima University Hospital, Hiroshima, Japan
| | - Nana Hayashi
- Department of Endoscopy, Hiroshima University Hospital, Hiroshima, Japan
| | - Kazuaki Chayama
- Department of Gastroenterology and Metabolism, Hiroshima University Hospital, Hiroshima, Japan
| |
Collapse
|
13
|
Spychalski M, Skulimowski A, Nishimura M, Dziki A. Comparison of Endoscopic Submucosal Dissection for Primary and Recurrent Colorectal Lesions: A Single-Center European Study. J Laparoendosc Adv Surg Tech A 2018; 29:366-373. [PMID: 30359169 DOI: 10.1089/lap.2018.0429] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
INTRODUCTION Endoscopic submucosal dissection (ESD) is an acknowledged endoscopic technique for the management of early gastrointestinal neoplasia. The clinical experience and the research from the Eastern ESD centers show that experienced endoscopists can successfully treat even the most demanding recurrent colorectal lesions. AIM The aim of this study was to analyze the clinical outcomes of the management of recurrent colorectal lesions in comparison with those of primary lesions in the setting of high-volume European center. METHODS A retrospective analysis of 298 cases (228 primary lesions and 70 recurrent lesions) performed by a single endoscopist was carried out. Evaluating learning curves for both primary and recurrent lesions, cumulative sum analysis was performed. RESULTS Primary lesions had ∼9% higher R0 resection rate (86.84% versus 78.51%). Yet, this difference did not reach statistical significance (P = .091). The presence of recurrent lesion and lengthy procedure (≥150 min) are risks factors of R1 resection, whereas rectal localization of the lesion was associated with lower risk of R1 resection. The cumulative R0 of 80% was achieved at 36th procedure in the primary lesions group, whereas for the recurrent lesions it was reached at 50th procedure (overall 229 procedures). CONCLUSIONS Our study underlines the importance of proper experience in ESD before the management of recurrent lesions. Even after the completion of high volume of primary lesions, first recurrent lesions can pose a challenge. Nevertheless, the final outcomes are promising, as the complications do not pose a serious risk to the patients and high R0 resection rate can be achieved in a reasonable timeframe.
Collapse
Affiliation(s)
- Michał Spychalski
- 1 Department of General and Colorectal Surgery, Multidisciplinary Hospital Brzeziny , Brzeziny, Poland
| | - Aleksander Skulimowski
- 1 Department of General and Colorectal Surgery, Multidisciplinary Hospital Brzeziny , Brzeziny, Poland
| | - Makoto Nishimura
- 2 Department of Gastrointestinal Endoscopy, Tokyo Metropolitan Geriatric Hospital and Institute of Gerontology , Tokyo, Japan
| | - Adam Dziki
- 3 Department of General and Colorectal Surgery, Medical University of Lodz , Lodz, Poland
| |
Collapse
|
14
|
Kuwai T, Yamaguchi T, Imagawa H, Miura R, Sumida Y, Takasago T, Miyasako Y, Nishimura T, Iio S, Yamaguchi A, Kouno H, Kohno H, Ishaq S. Endoscopic submucosal dissection for early esophageal neoplasms using the stag beetle knife. World J Gastroenterol 2018; 24:1632-1640. [PMID: 29686470 PMCID: PMC5910546 DOI: 10.3748/wjg.v24.i15.1632] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 03/16/2018] [Accepted: 03/30/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To determine short- and long-term outcomes of endoscopic submucosal dissection (ESD) using the stag beetle (SB) knife, a scissor-shaped device.
METHODS Seventy consecutive patients with 96 early esophageal neoplasms, who underwent ESD using a SB knife at Kure Medical Center and Chugoku Cancer Center, Japan, between April 2010 and August 2016, were retrospectively evaluated. Clinicopathological characteristics of lesions and procedural adverse events were assessed. Therapeutic success was evaluated on the basis of en bloc, histologically complete, and curative or non-curative resection rates. Overall and tumor-specific survival, local or distant recurrence, and 3- and 5-year cumulative overall metachronous cancer rates were also assessed.
RESULTS Eligible patients had dysplasia/intraepithelial neoplasia (22%) or early cancers (squamous cell carcinoma, 78%). The median procedural time was 60 min and on average, the lesions measured 24 mm in diameter, yielding 33-mm tissue defects. The en bloc resection rate was 100%, with 95% and 81% of dissections deemed histologically complete and curative, respectively. All procedures were completed without accidental incisions/perforations or delayed bleeding. During follow-up (mean, 35 ± 23 mo), no local recurrences or metastases were observed. The 3- and 5-year survival rates were 83% and 70%, respectively, with corresponding rates of 85% and 75% for curative resections and 74% and 49% for non-curative resections. The 3- and 5-year cumulative rates of metachronous cancer in the patients with curative resections were 14% and 26%, respectively.
CONCLUSION ESD procedures using the SB knife are feasible, safe, and effective for treating early esophageal neoplasms, yielding favorable short- and long-term outcomes.
Collapse
Affiliation(s)
- Toshio Kuwai
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Toshiki Yamaguchi
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Hiroki Imagawa
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Ryoichi Miura
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Yuki Sumida
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Takeshi Takasago
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Yuki Miyasako
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Tomoyuki Nishimura
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Sumio Iio
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Atsushi Yamaguchi
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Hirotaka Kouno
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Hiroshi Kohno
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Sauid Ishaq
- Department of Gastroenterology, DGH, SGU, WI, Birmingham City University, Birmingham B4 7BD, United Kingdom
| |
Collapse
|
15
|
Emmanuel A, Gulati S, Burt M, Hayee B, Haji A. Colorectal endoscopic submucosal dissection: patient selection and special considerations. Clin Exp Gastroenterol 2017; 10:121-131. [PMID: 28761366 PMCID: PMC5516776 DOI: 10.2147/ceg.s120395] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Endoscopic submucosal dissection (ESD) enables en bloc resection of large complex colorectal superficial neoplastic lesions, resulting in very low rates of local recurrence, high-quality pathologic specimens for accurate histopathologic diagnosis and potentially curative treatment of early adenocarcinoma without resorting to major surgical resection. The safety and efficacy of the technique, which was pioneered in the upper gastrointestinal tract, has been established by the consistently impressive outcomes from expert centers in Japan and some other eastern countries. However, ESD is challenging to perform in the colorectum and there is a significant risk of complications, particularly in the early stages of the learning curve. Early studies from western centers raised concerns about the high complication rates, and the impressive results from Japanese centers were not replicated. As a result, many western endoscopists are skeptical about the role of ESD and few centers have incorporated the technique into their practice. Nevertheless, although the distribution of expertise, referral centers and modes of practice may differ in Japan and western countries, ESD has an important role and can be safely and effectively incorporated into western practice. Key to achieving this is meticulous lesion assessment and selection, appropriate referral to centers with the necessary expertise and experience and application of the appropriate technique individualized to the patient. This review discusses the advantages, risks and benefits of ESD to treat colorectal lesions and the importance of preprocedure lesion assessment and in vivo diagnosis and outlines a pragmatic rationale for appropriate lesion selection as well as the patient, technical and institutional factors that should be considered.
Collapse
Affiliation(s)
- Andrew Emmanuel
- King's Institute of Therapeutic Endoscopy, King's College Hospital, London, UK
| | - Shraddha Gulati
- King's Institute of Therapeutic Endoscopy, King's College Hospital, London, UK
| | - Margaret Burt
- King's Institute of Therapeutic Endoscopy, King's College Hospital, London, UK
| | - Bu'Hussain Hayee
- King's Institute of Therapeutic Endoscopy, King's College Hospital, London, UK
| | - Amyn Haji
- King's Institute of Therapeutic Endoscopy, King's College Hospital, London, UK
| |
Collapse
|
16
|
Fuccio L, Hassan C, Ponchon T, Mandolesi D, Farioli A, Cucchetti A, Frazzoni L, Bhandari P, Bellisario C, Bazzoli F, Repici A. Clinical outcomes after endoscopic submucosal dissection for colorectal neoplasia: a systematic review and meta-analysis. Gastrointest Endosc 2017; 86:74-86.e17. [PMID: 28254526 DOI: 10.1016/j.gie.2017.02.024] [Citation(s) in RCA: 163] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2016] [Accepted: 02/16/2017] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND AIMS Endoscopic submucosal dissection (ESD) is an endoscopic resection technique for lesions suspicious of superficial malignancy. It is performed using an ESD knife on its own (standard technique) or by the sequential use of a knife and a snare (hybrid technique). The experience with these techniques is different in Asian and non-Asian countries. We performed a systematic review and meta-analysis of available evidence on colorectal ESD. METHODS Electronic databases were searched up to August 2016 for studies evaluating R0, en bloc resection, and adverse event rates of both techniques for the treatment of colorectal lesions. Proportions were pooled by a random effects model. RESULTS Ninety-seven studies (71 performed in Asia) evaluated the standard technique and 12 studies (7 in Asia) the hybrid technique. The R0 resection rate of the standard technique was 82.9%, and it was significantly lower in non-Asian versus Asian countries: 71.3% versus 85.6%. The en bloc resection rate was 91% and was significantly lower in non-Asian versus Asian countries (81.2% vs 93%, respectively). Surgery was needed in 1.1% of the ESD-related adverse events, with a significant difference between non-Asian and Asian countries (3.1% vs 0.8%). The R0 and en bloc resection rates with the hybrid technique were significantly lower than those achieved with the standard technique: 60.6% and 68.4%, respectively, with similar adverse event rates. CONCLUSIONS In non-Asian countries the standard ESD technique is still failing to achieve acceptable levels of performance. The hybrid technique showed low R0 resection rates and should not be considered as an adequate alternative to the standard technique.
Collapse
Affiliation(s)
- Lorenzo Fuccio
- Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | | | - Thierry Ponchon
- Gastroenterology and Endoscopy, Edouard Herriot Hospital, Lyon, France
| | - Daniele Mandolesi
- Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | - Andrea Farioli
- Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | - Alessandro Cucchetti
- Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | - Leonardo Frazzoni
- Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | | | - Cristina Bellisario
- Department of Cancer Screening, Centre for Epidemiology and Prevention in Oncology (CPO), University Hospital Città della Salute e della Scienza di Torino, Turin, Italy
| | - Franco Bazzoli
- Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | - Alessandro Repici
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research and University Hospital, Rozzano (MI), Italy
| |
Collapse
|
17
|
Shiga H, Ohba R, Matsuhashi T, Jin M, Kuroha M, Endo K, Moroi R, Kayaba S, Iijima K. Feasibility of colorectal endoscopic submucosal dissection (ESD) carried out by endoscopists with no or little experience in gastric ESD. Dig Endosc 2017; 29 Suppl 2:58-65. [PMID: 28425662 DOI: 10.1111/den.12814] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Accepted: 01/16/2017] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIM Colorectal endoscopic submucosal dissection (ESD) is recommended to be carried out only by endoscopists with sufficient experience in gastric ESD. However, early gastric carcinoma is less common in Western countries than in Japan, and endoscopic maneuverability differs between the stomach and colorectum. We assessed the feasibility of colorectal ESD carried out by endoscopists with no or little experience in gastric ESD. METHODS We analyzed en bloc resection, R0 resection and perforation rates in 180 consecutive colorectal ESD carried out by three endoscopists who had no or <5 cases of experience in gastric ESD. We also identified factors associated with R0 resection failure. RESULTS Overall en bloc and R0 resection rates were 93.3% (168/180) and 82.2% (148/180), respectively. All 11 cases with perforation were treated endoscopically. Dividing 180 cases into three learning phases (early, middle, or late phases), the en bloc and R0 resection rates increased from 88.3% and 75.0% in the early phase to 98.3% and 88.3% in the late phase, respectively. Perforation rate also improved from 10.0% to 3.3%. Factors associated with R0 resection failure were location at junctions (odds ratio: 6.8, 95% CI: 1.9-27.5), preoperative factors reflecting fibrosis (5.8, 1.9-19.0), and late phase (0.2, 0.1-0.7). CONCLUSION Endoscopists without experience in gastric ESD carried out colorectal ESD safely. In the early and middle phases (≤40 cases), they should treat mainly rectal lesions but may also resect lesions in the colon avoiding flexures. Lesions located at junctions and those with preoperative factors reflecting fibrosis should be resected after completing 40 procedures.
Collapse
Affiliation(s)
- Hisashi Shiga
- Department of Gastroenterology and Neurology, Akita University Graduate School of Medicine, Akita, Japan
| | - Reina Ohba
- Department of Gastroenterology and Neurology, Akita University Graduate School of Medicine, Akita, Japan
| | - Tamotsu Matsuhashi
- Department of Gastroenterology and Neurology, Akita University Graduate School of Medicine, Akita, Japan
| | - Mario Jin
- Department of Gastroenterology and Neurology, Akita University Graduate School of Medicine, Akita, Japan
| | - Masatake Kuroha
- Division of Gastroenterology, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Katsuya Endo
- Division of Gastroenterology, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Rintaro Moroi
- Department of Gastroenterology, Iwate Prefectural Isawa Hospital, Oshu, Japan
| | - Shoichi Kayaba
- Department of Gastroenterology, Iwate Prefectural Isawa Hospital, Oshu, Japan
| | - Katsunori Iijima
- Department of Gastroenterology and Neurology, Akita University Graduate School of Medicine, Akita, Japan
| |
Collapse
|
18
|
Sauer M, Hildenbrand R, Oyama T, Sido B, Yahagi N, Dumoulin FL. Endoscopic submucosal dissection for flat or sessile colorectal neoplasia > 20 mm: A European single-center series of 182 cases. Endosc Int Open 2016; 4:E895-900. [PMID: 27540580 PMCID: PMC4988858 DOI: 10.1055/s-0042-111204] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Accepted: 06/13/2016] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND AND STUDY AIMS Colorectal endoscopic submucosal dissection (ESD) is an attractive method for en bloc resection of larger flat neoplastic lesions. Experience with this method is limited in the Western World. PATIENTS AND METHODS A total of 182 consecutive flat or sessile colorectal lesions (cecum n = 43; right-sided colon n = 65; left-sided colon n = 11, rectum: n = 63) with a size > 20 mm (mean 41.0 ± 17.4 mm) were resected in 178 patients. The data were recorded prospectively. RESULTS ESD was technically feasible in 85.2 % of patients with a mean procedure time of 127.5 min (± 99.8) min and a complication rate of 11.5 % (microperforation 9.3 %, delayed bleeding 2.7 %, no case of emergency surgery, 30-day mortality rate 0 %). For 155 successfully completed procedures the en bloc and R0 resection rates were 88.4 and 62.6 %. Efficacy was better for smaller lesions (20 mm to 49 mm; n = 131) than for larger lesions (50 mm to 140 mm; n = 51) with R0 rates of 70.8 vs. 40.5 % (P < 0.001) and procedure times of 92.7 ± 62.4 minutes vs. 217.0 ± 120.9 minutes (P < 0,001). CONCLUSIONS This series confirms the efficacy of ESD for en bloc resection of colorectal lesions > 20 mm. RESULTS are satisfactory for lesions up to 50 mm. ESD for larger lesions was associated with low R0 resection rates and very long procedure times. The clinical consequences of microperforations were minor and do not argue against the spread of ESD in the West. Meeting presentations: The data were presented in part at DDW 2014, Chicago IL, USA (Gastrointest Endosc 2014; 79: AB536).
Collapse
Affiliation(s)
- Malte Sauer
- Department of Medicine and Gastroenterology, Gemeinschaftskrankenhaus Bonn, Bonn, Germany
| | | | - Tsuneo Oyama
- Department of Endoscopy, Saku Central Hospital Advanced Care Center, Nagano, Japan
| | - Bernd Sido
- Department of General and Abdominal Surgery, Gemeinschaftskrankenhaus Bonn, Bonn, Germany
| | - Naohisa Yahagi
- Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Tokyo, Japan
| | - Franz Ludwig Dumoulin
- Department of Medicine and Gastroenterology, Gemeinschaftskrankenhaus Bonn, Bonn, Germany ,Corresponding author Franz Ludwig Dumoulin, MD, PhD Department of Medicine and GastroenterologyGemeinschaftskrankenhaus BonnBonner Talweg 4-6D-53113 BonnGermany+49-228-508-1561+49-228-508-1562
| |
Collapse
|
19
|
Fukami N. Large colorectal lesions: Is it possible to stratify the lesions for optimal treatment in the right hands? Gastrointest Endosc 2016; 83:963-5. [PMID: 27102529 DOI: 10.1016/j.gie.2016.01.063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 01/29/2016] [Indexed: 02/08/2023]
Affiliation(s)
- Norio Fukami
- Division of Gastroenterology and Hepatology, Mayo Clinic, Arizona
| |
Collapse
|