D'Ancona G, Safak E, Senges J, Hochadel M, Nguyen VL, Perings C, Jung W, Spitzer S, Eckardt L, Brachmann J, Seidl K, Hink HU, Ince H, Ortak J. Activation of remote monitoring for cardiac implantable electronic devices: small dog for tall weeds. Clin Res Cardiol 2017; 106:833-839. [PMID: 28593341 DOI: 10.1007/s00392-017-1127-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 06/01/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) has been popularized as a precious patients' management tool. We have investigated RM within the premises of a multicenter, prospective, real-world registry, i.e., the German Device II. METHODS We have focused on: (1) CIEDs with RM capabilities implantation rate and (2) actual rate of RM features activation. RESULTS A cohort of 1223 CIEDs patients were treated from 04/11 to 02/14. Of these, 720 (58.8%) were implanted with RM-capable devices and were presenting significantly more often a clinical diagnosis of dilatative cardiomyopathy and an indication for cardiac resynchronization. At discharge, the RM feature was activated in only 12.6% (91/720) of the total number of patients implanted with RM-capable CIEDs. After adjusting for implanting center, there was no significant correlation between any of the patient clinical characteristics and RM activation. One-year estimated mortality was 9.0% in patients with activated RM, 5.6% in those with not activated RM, and 7.7% in those without RM capability (p = 0.3). The RM feature was still activated in 13.8% of the patients surviving at follow-up. Patients undergoing RM had a trend for higher re-hospitalization rate and less visits in the device outpatient clinic. CONCLUSIONS Although RM in CIEDs may be a clinically valuable technological armamentarium, its activation does not reflect patients' clinical profile. In fact, RM is often not activated, most probably because it is still recognized as a source of increased workload in a reality where reimbursement plans for dedicated human resources are not yet optimized.
Collapse
Affiliation(s)
- Giuseppe D'Ancona
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany. .,Rostock University Medical Center, Rostock, Germany.
| | - Erdal Safak
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany.,Rostock University Medical Center, Rostock, Germany
| | - Jochen Senges
- Stiftung Institut für Herzinfarktforschung, Ludwigshafen am Rhein, Germany
| | - Matthias Hochadel
- Stiftung Institut für Herzinfarktforschung, Ludwigshafen am Rhein, Germany
| | - Van Luyen Nguyen
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany.,Rostock University Medical Center, Rostock, Germany
| | | | - Werner Jung
- Schwarzwald-Baar Klinikum, Klinik für Innere Medizin III Kardiologie, Villingen-Schwenningen, Germany
| | - Stefan Spitzer
- Praxisklinik Herz und Gefäße Dresden, Institute of Medical Technology Brandenburg University of Technology Cottbus, Senftenberg, Germany
| | - Lars Eckardt
- Division of Experimental and Clinical Electrophysiology, Department of Cardiology and Angiology, University of Muenster, Münster, Germany
| | | | | | | | - Hüseyin Ince
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany.,Rostock University Medical Center, Rostock, Germany
| | - Jasmin Ortak
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany.,Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
2
|
de Cock CC, Elders J, van Hemel NM, van den Broek K, van Erven L, de Mol B, Talmon J, Theuns DAMJ, de Voogt W. Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands : An expert consensus report of the Netherlands Society of Cardiology. Neth Heart J 2012; 20:53-65. [PMID: 22249958 PMCID: PMC3265700 DOI: 10.1007/s12471-011-0239-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Remote monitoring of cardiac implanted electronic devices (CIED: pacemaker, cardiac resynchronisation therapy device and implantable cardioverter defibrillator) has been developed for technical control and follow-up using transtelephonic data transmission. In addition, automatic or patient-triggered alerts are sent to the cardiologist or allied professional who can respond if necessary with various interventions. The advantage of remote monitoring appears obvious in impending CIED failures and suspected symptoms but is less likely in routine follow-up of CIED. For this follow-up the indications, quality of care, cost-effectiveneness and patient satisfaction have to be determined before remote CIED monitoring can be applied in daily practice. Nevertheless remote CIED monitoring is expanding rapidly in the Netherlands without professional agreements about methodology, responsibilities of all the parties involved and that of the device patient, and reimbursement. The purpose of this consensus document on remote CIED monitoring and follow-up is to lay the base for a nationwide, uniform implementation in the Netherlands. This report describes the technical communication, current indications, benefits and limitations of remote CIED monitoring and follow-up, the role of the patient and device manufacturer, and costs and reimbursement. The view of cardiology experts and of other disciplines in conjunction with literature was incorporated in a preliminary series of recommendations. In addition, an overview of the questions related to remote CIED monitoring that need to be answered is given. This consensus document can be used for future guidelines for the Dutch profession.
Collapse
Affiliation(s)
- C C de Cock
- Department of Cardiology, VU University Medical Center, Boelelaan 1117, 1081 HV, Amsterdam, the Netherlands,
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Dubner S, Auricchio A, Steinberg JS, Vardas P, Stone P, Brugada J, Piotrowicz R, Hayes DL, Kirchhof P, Breithardt G, Zareba W, Schuger C, Aktas MK, Chudzik M, Mittal S, Varma N, Israel (Germany) C, Padeletti (Italy) L, Brignole (Italy) M. ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs). Europace 2012; 14:278-93. [DOI: 10.1093/europace/eur303] [Citation(s) in RCA: 131] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
4
|
Dubner S, Auricchio A, Steinberg JS, Vardas P, Stone P, Brugada J, Piotrowicz R, Hayes DL, Kirchhof P, Breithardt G, Zareba W, Schuger C, Aktas MK, Chudzik M, Mittal S, Varma N. ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs). Ann Noninvasive Electrocardiol 2012; 17:36-56. [PMID: 22276627 PMCID: PMC6932107 DOI: 10.1111/j.1542-474x.2011.00484.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
We are in the midst of a rapidly evolving era of technology-assisted medicine. The field of telemedicine provides the opportunity for highly individualized medical management in a way that has never been possible before. Evolving medical technologies using cardiac implantable devices with capabilities for remote monitoring permit evaluation of multiple parameters of cardiovascular physiology and risk, including cardiac rhythm, device function, blood pressure values, the presence of myocardial ischaemia, and the degree of compensation of congestive heart failure. Cardiac risk, device status, and response to therapies can now be assessed with these electronic systems of detection and reporting. This document reflects the extensive experience from investigators and innovators around the world who are shaping the evolution of this rapidly expanding field, focusing in particular on implantable pacemakers, implantable cardioverter defibrillators, devices for cardiac resynchronization therapy (both with and without defibrillation properties), loop recorders, and hemodynamic monitoring devices. This document covers the basic methodologies, guidelines for their use, experience with existing applications, and the legal and reimbursement aspects associated with their use. To adequately cover this important emerging topic, the International Society for Holter and Noninvasive Electrocardiology and the European Heart Rhythm Association combined their expertise in this field. We hope that the development of this field can contribute to improve care of our cardiovascular patients.
Collapse
Affiliation(s)
- Sergio Dubner
- Clinica y Maternidad Suizo Argentina, Buenos Aires, Argentina.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Biotronik Home Monitoring system in clinical practice. COR ET VASA 2011. [DOI: 10.33678/cor.2011.155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
6
|
BLANCK ZALMEN, AXTELL KATHI, BRODHAGEN KATHY, O'HEARN LAURA, ALBELO TAMMY, CERETTO CHERYL, DHALA ANWER, SRA JASBIR, AKHTAR MASOOD. Inappropriate Shocks in Patients With Fidelis® Lead Fractures: Impact of Remote Monitoring and the Lead Integrity Algorithm. J Cardiovasc Electrophysiol 2011; 22:1107-14. [DOI: 10.1111/j.1540-8167.2011.02077.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
7
|
Perings C, Bauer WR, Bondke HJ, Mewis C, James M, Böcker D, Broadhurst P, Korte T, Toft E, Hintringer F, Clémenty J, Schwab JO. Remote monitoring of implantable-cardioverter defibrillators: results from the Reliability of IEGM Online Interpretation (RIONI) study. Europace 2011; 13:221-9. [PMID: 21252195 DOI: 10.1093/europace/euq447] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Intracardiac electrograms (IEGMs) recorded by implantable cardioverter-defibrillators (ICDs) are essential for arrhythmia diagnosis and ICD therapy assessment. Short IEGM snapshots showing 3-10 s before arrhythmia detection were added to the Biotronik Home Monitoring system in 2005 as the first-generation IEGM Online. The RIONI study tested the primary hypothesis that experts' ratings regarding the appropriateness of ICD therapy based on IEGM Online and on standard 30 s IEGM differ in <10% of arrhythmia events. METHODS AND RESULTS A total of 619 ICD patients were enrolled and followed for 1 year. According to a predefined procedure, 210 events recorded by the ICDs were selected for evaluation. Three expert board members rated the appropriateness of ICD therapy and classified the underlying arrhythmia using coded IEGM Online and standard IEGM to avoid bias. The average duration of IEGM Online was 4.4±1.5 s. According to standard IEGM, the underlying arrhythmia was ventricular in 135 episodes (64.3%), supraventricular in 53 episodes (25.2%), oversensing in 17 episodes (8.1%), and uncertain in 5 episodes (2.4%). The expert board's rating diverged between determinable IEGM Online tracings and standard IEGM in 4.6% of episodes regarding the appropriateness of ICD therapy (95% CI up to 8.0%) and in 6.6% of episodes regarding arrhythmia classification (95% CI up to 10.5%). CONCLUSION By enabling accurate evaluation of the appropriateness of ICD therapy and the underlying arrhythmia, the first-generation IEGM Online provided a clinically effective basis for timely interventions and for optimized patient management schemes, which was comparable with current IEGM recordings.
Collapse
Affiliation(s)
- Christian Perings
- Department of Cardiology and Angiology, Marienhospital Herne, University of Bochum, Bochum, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Marcus GM, Chan DW, Redberg RF. Recollection of pain due to inappropriate versus appropriate implantable cardioverter-defibrillator shocks. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2010; 34:348-53. [PMID: 21077915 DOI: 10.1111/j.1540-8159.2010.02971.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Although inappropriate shocks are known to be an important consequence of implantable cardioverter-defibrillators (ICDs), the subjective experience of pain intensity perceived by those receiving inappropriate versus appropriate shocks has not previously been examined. METHODS One hundred ICD patients underwent a standardized interview by an investigator blinded to the clinical history. Patients with a previous ICD shock were asked to describe the intensity of the associated pain on a standard 0-10 scale (10 being the worst pain they had ever experienced). Medical charts were then examined for any history of inappropriate and/or appropriate ICD discharges. RESULTS Thirty-five of the 100 patients had a record of at least one ICD shock, and 17 had experienced at least one inappropriate shock. Those with a history of an inappropriate shock described a significantly higher median pain scale (9, interquartile range [IQR] 8-10) compared to those with a history of only appropriate shocks (median 4, IQR 2-8, P = 0.0011). In multivariable analysis, a history of an inappropriate shock was the only predictor statistically significantly associated with an increase in shock pain: the pain scale for those with inappropriate shocks was higher by 2.8 points on average after multivariable adjustment (95% confidence interval 0.29-5, P = 0.030). Eighteen patients had considered having their device deactivated, and a history of an inappropriate shock was the only factor independently associated with this consideration. CONCLUSIONS Compared to those who have received only appropriate shocks, inappropriate ICD shocks are associated with a recollection of greater pain and consideration of device inactivation.
Collapse
Affiliation(s)
- Gregory M Marcus
- Cardiac Electrophysiology Section, University of California, San Francisco, California, USA.
| | | | | |
Collapse
|
9
|
Osca J, Sanchotello MJ, Navarro J, Cano O, Raso R, Castro JE, Olagüe J, Salvador A. Technical reliability and clinical safety of a remote monitoring system for antiarrhythmic cardiac devices. Rev Esp Cardiol 2009; 62:886-95. [PMID: 19706244 DOI: 10.1016/s1885-5857(09)72653-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
INTRODUCTION AND OBJECTIVES In recent years, physicians have experienced a huge increase in workload associated with cardiac devices. Remote monitoring enables these devices to be monitored at a distance and could reduce the number of hospital visits. The aim of this study was to assess the technical reliability and clinical safety of the Home MonitoringTM remote monitoring system (Biotronik GmbH, Germany). METHODS The study included 162 patients: 115 with pacemakers, 44 with implantable cardioverter-defibrillators (ICDs) and three with ICDs incorporating cardiac resynchronization therapy (CRT). Patients were followed up for a mean of 303+/-244 days. We compared the survival time free of event alerts in patients with pacemakers and in those with ICDs. The remote monitoring system's reliability was evaluated by comparing the data it transmitted with clinical observations made immediately afterwards. RESULTS The mean percentage of days monitored was 88.2%. The incidence of event alerts was higher in pacemaker than ICD patients (45% vs. 34%; P=.01). Event alerts preceded the following hospital visit by 76+/-47 days. In the ICD group, the data sent by the monitoring system were judged as true-positives in 42% of cases, as true-negatives in 57% and as false-positives in 1%. No false-negative was observed. In the ICD group, the remote monitoring system had a sensitivity of 100% and a specificity of 97% (positive predictive value 96%, negative predictive value 100%). CONCLUSIONS Remote monitoring was a reliable and safe method for following up patients with cardiac devices. Its routine use could enable the early detection of device malfunctions or arrhythmic events.
Collapse
Affiliation(s)
- Joaquín Osca
- Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario La Fe, Valencia, Spain.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Osca J, Tello MJS, Navarro J, Cano Ó, Raso R, Castro JE, Olagüe J, Salvador A. Fiabilidad técnica y seguridad clínica de un sistema de monitorización remota de dispositivos cardiacos antiarrítmicos. Rev Esp Cardiol 2009. [DOI: 10.1016/s0300-8932(09)72071-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
11
|
Müller A, Helms TM, Neuzner J, Schweizer J, Korb H. Schrittmacher und interne Defibrillatoren mit kardiotelemedizinischer Unterstützung. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2009; 52:306-15. [DOI: 10.1007/s00103-009-0793-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
12
|
Masella C, Zanaboni P, Di Stasi F, Gilardi S, Ponzi P, Valsecchi S. Assessment of a remote monitoring system for implantable cardioverter defibrillators. J Telemed Telecare 2008; 14:290-4. [PMID: 18776073 DOI: 10.1258/jtt.2008.080202] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
We conducted a multicentre study in five Italian hospitals to assess the feasibility of a remote monitoring service for the follow-up of implanted cardiac devices. The system was designed to monitor device performance as well as physiological aspects of the patient's condition. Sixty-seven patients (mean age 64 years) affected by chronic heart failure and with a biventricular implantable cardioverter defibrillator for cardiac re-synchronization therapy (CRT-D) were enrolled for a three-month observation period. A total of 267 device recordings were transmitted through the ordinary telephone network, with a success rate of 99%. The telemonitoring service was more efficient than conventional face-to-face follow-up in terms of the time savings: both for physicians (4.7 minutes versus 15 minutes for remote and conventional monitoring) and for patients (6.6 minutes versus 116.3 minutes). In addition, a total of 23 clinical events occurred during the study, but only two cases required a clinic visit, thus reducing inappropriate hospital admissions. Finally, the service was well accepted by all the users.
Collapse
Affiliation(s)
- Cristina Masella
- Department of Management, Economics and Industrial Engineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | | | | | | | | | | |
Collapse
|
13
|
Raatikainen MJP, Uusimaa P, van Ginneken MME, Janssen JPG, Linnaluoto M. Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up. Europace 2008; 10:1145-51. [PMID: 18703585 PMCID: PMC2552405 DOI: 10.1093/europace/eun203] [Citation(s) in RCA: 147] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Aims The purpose of this prospective study was to investigate whether internet-based remote monitoring offers a safe, practical, and cost-effective alternative to the in-office follow-up visits of patients with an implantable cardioverter defibrillator (ICD). Methods and results Forty-one patients (62 ± 10 years, range 41–76, 83% male) with previously implanted ICD were followed for 9 months. One-hundred and nineteen scheduled and 18 unscheduled data transmissions were performed. There were no device-related adverse events. Over 90% of the patients found the system easy to use. Physicians reported the system as being ‘very easy’ or ‘easy’ to use and found the data comparable to traditional device interrogation in 99% of the cases. They were able to address all unscheduled data transmissions remotely. Compared with the in-office visits, remote monitoring required less time from patients (6.9 ± 5.0 vs. 182 ± 148 min, P < 0.001) and physicians (8.4 ± 4.5 vs. 25.8 ± 17.0 min, P < 0.001) to complete the follow-up. Substitution of two routine in-office visits during the study by remote monitoring reduced the overall cost of routine ICD follow-up by 524€ per patient (41%). Conclusion Remote monitoring offers a safe, feasible, time-saving, and cost-effective solution to ICD follow-up.
Collapse
Affiliation(s)
- M J Pekka Raatikainen
- Division of Cardiology, Department of Internal Medicine, University of Oulu, PO Box 5000, 90014 Oulu, Finland.
| | | | | | | | | |
Collapse
|
14
|
Wilkoff BL, Auricchio A, Brugada J, Cowie M, Ellenbogen KA, Gillis AM, Hayes DL, Howlett JG, Kautzner J, Love CJ, Morgan JM, Priori SG, Reynolds DW, Schoenfeld MH, Vardas PE. HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): Description of Techniques, Indications, Personnel, Frequency and Ethical Considerations. Heart Rhythm 2008; 5:907-25. [DOI: 10.1016/j.hrthm.2008.04.013] [Citation(s) in RCA: 230] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
15
|
Daubert JP, Zareba W, Cannom DS, McNitt S, Rosero SZ, Wang P, Schuger C, Steinberg JS, Higgins SL, Wilber DJ, Klein H, Andrews ML, Hall WJ, Moss AJ. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol 2008; 51:1357-65. [PMID: 18387436 DOI: 10.1016/j.jacc.2007.09.073] [Citation(s) in RCA: 597] [Impact Index Per Article: 37.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2007] [Revised: 09/19/2007] [Accepted: 09/23/2007] [Indexed: 01/11/2023]
Abstract
OBJECTIVES This study sought to identify the incidence and outcome related to inappropriate implantable cardioverter-defibrillator (ICD) shocks, that is, those for nonventricular arrhythmias. BACKGROUND The MADIT (Multicenter Automatic Defibrillator Implantation Trial) II showed that prophylactic ICD implantation improves survival in post-myocardial infarction patients with reduced ejection fraction. Inappropriate ICD shocks are common adverse consequences that may impair quality of life. METHODS Stored ICD electrograms from all shock episodes were adjudicated centrally. An inappropriate shock episode was defined as an episode during which 1 or more inappropriate shocks occurred; another inappropriate ICD episode occurring within 5 min was not counted. Programmed parameters for patients with and without inappropriate shocks were compared. RESULTS One or more inappropriate shocks occurred in 83 (11.5%) of the 719 MADIT II ICD patients. Inappropriate shock episodes constituted 184 of the 590 total shock episodes (31.2%). Smoking, prior atrial fibrillation, diastolic hypertension, and antecedent appropriate shock predicted inappropriate shock occurrence. Atrial fibrillation was the most common trigger for inappropriate shock (44%), followed by supraventricular tachycardia (36%), and then abnormal sensing (20%). The stability detection algorithm was programmed less frequently in patients receiving inappropriate shocks (17% vs. 36%, p = 0.030), whereas other programming parameters did not differ significantly from those without inappropriate shocks. Importantly, patients with inappropriate shocks had a greater likelihood of all-cause mortality in follow-up (hazard ratio 2.29, p = 0.025). CONCLUSIONS Inappropriate ICD shocks occurred commonly in the MADIT II study, and were associated with increased risk of all-cause mortality.
Collapse
Affiliation(s)
- James P Daubert
- Cardiology Division, Department of Medicine, University of Rochester Medical Center, Rochester, New York, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Chen J, Wilkoff BL, Choucair W, Cohen TJ, Crossley GH, Johnson WB, Mongeon LR, Serwer GA, Sherfesee L. Design of the Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial to assess the clinical value of the remote pacemaker interrogation in the management of pacemaker patients. Trials 2008; 9:18. [PMID: 18387185 PMCID: PMC2311273 DOI: 10.1186/1745-6215-9-18] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2008] [Accepted: 04/03/2008] [Indexed: 11/25/2022] Open
Abstract
Background Although pacemakers are primarily used for the treatment of bradycardia, diagnostic data available in current pacemakers allow them to be also used as sophisticated, continuous monitoring devices. Easy access to these stored data may assist clinicians in making diagnostic and therapeutic decisions sooner, thus avoiding potential long-term sequelae due to untreated clinical disorders. Internet-based remote device interrogation systems provide clinicians with frequent and complete access to stored data in pacemakers. In addition to monitoring device function, remote monitors may be a helpful tool in assisting physicians in the management of common arrhythmia disorders. Methods The Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial is a prospective, randomized, parallel, unblinded, multicenter, open label clinical trial to determine the utility of remote pacemaker interrogation in the earlier diagnosis of clinically actionable events compared to the existing practice of transtelephonic monitoring. There have been 980 patients enrolled and randomized to receive pacemaker follow up with either remote interrogation using the Medtronic CareLink® Network (CareLink) versus the conventional method of transtelephonic monitoring (TTM) in addition to periodic in-person interrogation and programming evaluations. The purpose of this manuscript is to describe the design of the PREFER trial. The results, to be presented separately, will characterize the number of clinically actionable events as a result of pacemaker follow-up using remote interrogation instead of TTM. Trial registration ClinicalTrials.gov: NCT00294645.
Collapse
Affiliation(s)
- Jane Chen
- Department of Internal Medicine, Cardiovascular Division, Washington University School of Medicine, Saint Louis, Missouri, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
The major device manufacturers have introduced systems for remote patient monitoring. These remote monitoring systems promise more efficient patient management, especially in today's clinical setting with the growing number of defibrillator implantations. The aim of this article is to present the role of remote patient monitoring in implantable cardioverter-defibrillator follow-up, its potential benefits and its barriers to widespread diffusion. (Neth Heart J 2008;16:53-6.).
Collapse
Affiliation(s)
- D A M J Theuns
- Department of Cardiology, Erasmus Medical Centre, Rotterdam, the Netherlands
| | | |
Collapse
|
18
|
Grothoff M, Spors B, Abdul-Khaliq H, Abd El Rahman M, Alexi-Meskishvili V, Lange P, Felix R, Gutberlet M. Pulmonary regurgitation is a powerful factor influencing QRS duration in patients after surgical repair of tetralogy of Fallot. Clin Res Cardiol 2006; 95:643-9. [PMID: 17021680 DOI: 10.1007/s00392-006-0440-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2006] [Accepted: 08/11/2006] [Indexed: 11/30/2022]
Abstract
AIMS QRS prolongation is a negative prognostic factor for the development of ventricular arrhythmia after repair of tetralogy of Fallot (TOF). In this MRI study, we performed a multivariate analysis to determine the influence of volumetric and functional parameters as well as time factors on QRS duration. METHODS AND RESULTS Sixty-seven patients after surgical repair of TOF were studied using a 1.5T MRI. Measurement of the ventricles was performed with a multislice-multiphase sequence. Left and right ventricular volumes, ejection fractions (EF) and myocardial masses were determined. Pulmonary regurgitant fraction (PRF) was quantified by velocity encoded flow measurement in the main pulmonary artery. Maximum QRS duration was taken from a 12-channel ECG. Mean maximum QRS duration was 132 ms (+/- 29 ms). Mean PRF was 29.2% (+/- 13.4%). QRS duration correlated significantly with PRF (r = 0.49; p < 0.01; n = 54) and with right ventricular enddiastolic volume index (RVEDVI) (r = 0.29; p < 0.05; n = 67). Multivariate analysis revealed that the combination of PRF, postoperative period, age at surgical repair, and left ventricular (LV) enddiastolic volume are correlated with QRS prolongation. CONCLUSION In patients after repair of TOF, pulmonary regurgitation is related to QRS prolongation. Furthermore, even LV size plays a role in the enlargement of the QRS complex.
Collapse
Affiliation(s)
- M Grothoff
- Department of Radiology and Nuclear Medicine, Charité, Campus Virchow Klinikum, Augustenburger Platz 1, 13353, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|