1
|
Khalifa AA, Abdelaal AM. Does the placement of acetabular cups differ between right and left sides for a right-handed surgeon operating through a direct lateral approach? A comparative study. ARTHROPLASTY 2024; 6:58. [PMID: 39497213 PMCID: PMC11536924 DOI: 10.1186/s42836-024-00278-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 09/03/2024] [Indexed: 11/07/2024] Open
Abstract
PURPOSE Although many factors were suggested to affect acetabular cup positioning during primary total hip arthroplasty, the effect of surgeon handedness was rarely evaluated. We aimed primarily to assess the difference in cup positioning (inclination and anteversion) between the right and left sides during primary THA. Secondly, to check the difference in the percentages of cups positioned in the safe zone for inclination and anteversion and if there will be a difference in cup positioning according to the type of cup fixation (cemented vs. cementless). METHODS Cup inclination and anteversion of 420 THAs were radiographically evaluated retrospectively. THAs were performed by a senior right-handed surgeon, who operated through a direct lateral approach in a lateral decubitus position using manual instruments and freehand technique for cup placement. Patients were assigned to two groups: Group A (right, or dominant side), and Group B (left, or non-dominant side), with equal cases of THAs (n = 210) in each group. RESULTS No difference was found in patients' basic characteristics, preoperative diagnosis, and cup fixation (54.3% cemented and 45.7% cementless) between the two groups. There was a significant difference in cup inclination between Groups A and Group B (40.1° ± 6.3° vs. 38.2° ± 6.1°) (P = 0.002). No significant difference was revealed in anteversion between the two groups (11.7° ± 4.4° vs. 11.8° ± 4.7°) (P = 0.95). The percentage of cups located within the safe zone in terms of both inclination and anteversion was 85.2% vs. 83.8% and 69% vs. 73.3% for Group A and Group B, according to Lewinnek and Callahan's safe zones, respectively. There existed a significant difference in the cemented cup inclination between Group A and Group B (40.8° ± 6.4° vs. 38.3° ± 6.3°) (P = 0.004). CONCLUSION Cup inclination is affected by the surgeon's handedness when operating through a direct lateral approach and using a freehand technique, while anteversion is less affected. Furthermore, the difference is greater with cemented cups.
Collapse
Affiliation(s)
- Ahmed A Khalifa
- Orthopaedic Department, Qena University Hospital, Qena, 83523, Egypt
| | - Ahmed M Abdelaal
- Department of Orthopedic Surgery and Traumatology, Assiut University Hospital, Assiut, 71515, Egypt.
| |
Collapse
|
2
|
Miura T, Yamamoto N, Shiroshita A, Tsuge T, Saitsu A, Yoshitani J, Nakao S, Takami K. Comparison of Implant Placement Accuracy Between Manual, Robot-Assisted, Computer-Navigated, Augmented Reality Navigated, Patient-Specific Instrumentation, and Accelerometer Navigated Total Hip Arthroplasty: A Systematic Review and Network Meta-Analysis. JBJS Rev 2024; 12:01874474-202411000-00001. [PMID: 39499789 DOI: 10.2106/jbjs.rvw.24.00120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2024]
Abstract
BACKGROUND Malpositioning of the acetabular cup during total hip arthroplasty (THA) can lead to complications. Robotic surgery and navigation techniques aim to address this issue, but there is limited evidence regarding which method can achieve better clinical outcomes. Therefore, this network meta-analysis (NMA) aimed to compare the efficacy of various navigation methods. METHODS This NMA of prospective randomized controlled trials compared robot-assisted systems (RAS), computer-assisted navigation systems (CAS), augmented reality-based portable navigation (AR), patient-specific instrumentation (PSI), portable accelerometer-based navigation (PN), and conventional methods (C) for THA procedures. We searched MEDLINE, EMBASE, Cochrane, Central Register of Controlled Trials, International Clinical Trials Platform Search Portal, and ClinicalTrials.gov. databases. The primary outcomes included revision surgery and postoperative clinical scores, and the secondary outcomes encompassed cup placement accuracy, acetabular cup placement outliers from the Lewinnek safe zone, surgical time, and complications. We used a Bayesian random-effects NMA, and confidence of evidence was assessed using confidence in NMA. RESULTS We identified 45 studies including 2,122 patients. We did not find large differences in revision surgery, clinical outcome scores, cup inclination, or anteversion angle accuracy among the modalities. AR, CAS, and PSI exhibited a lower risk of outliers from safe zones than C. In addition, RAS and CAS had a longer surgical time than C. CONCLUSIONS Robotic and navigation tools did not reduce the revision risk or enhance clinical outcomes. AR, CAS, PSI, and PN may decrease the risk of cup placement outliers in safe zones. However, the cup placement accuracy was equivalent, and the surgical time may be longer in RAS and CAS than in C. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Takanori Miura
- Department of Orthopaedic Surgery, Matsuda Hospital, Sendai, Japan
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan
| | - Norio Yamamoto
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan
- Department of Epidemiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
- Department of Orthopedic Surgery, Hashimoto Hospital, Mitoyo, Japan
| | - Akihiro Shiroshita
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan
- Division of Epidemiology, Department of Medicine, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Takahiro Tsuge
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan
- Department of Epidemiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
- Department of Rehabilitation, Kurashiki Medical Center, Kurashiki, Japan
| | - Akihiro Saitsu
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan
- R & D Division of Career Education for Medical Professionals, Medical Education Center, Jichi Medical University, Shimotsuke, Japan
- Department of Orthopaedics Surgery, Jichi Medical University, Shimotsuke, Japan
| | - Junya Yoshitani
- Department of Orthopedic Surgery, Suzu General Hospital, Suzu, Japan
| | - Shuri Nakao
- Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan
- Division of Rehabilitation Medicine, Shimane University Hospital, Izumo, Japan
| | - Ken Takami
- School of Public Health, University of California, Berkeley, Berkeley, California
| |
Collapse
|
3
|
Khalifa AA, Hassan AA. Surgeon handedness affects the acetabular cup positioning during primary total hip arthroplasty regardless of the surgical approach. a systematic review and metanalysis. BMC Musculoskelet Disord 2024; 25:792. [PMID: 39375663 PMCID: PMC11460204 DOI: 10.1186/s12891-024-07868-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 09/11/2024] [Indexed: 10/09/2024] Open
Abstract
PURPOSE The aim was to investigate the effect of surgeon handedness on acetabular cup positioning, functional outcomes, and dislocation incidence during primary THA. METHODS A systematic review was conducted according to the PRISMA guidelines. Studies published in English were searched in three databases (PubMed, Embase, and Scopus). A dominant side is a right-handed (RHD) or left-handed (LHD) surgeon who operates on the right or left hip, respectively. The opposite is considered to be the non-dominant side. We used odds ratios for dichotomous data and mean differences for continuous data, with 95% confidence intervals for quantitative data synthesis. Heterogeneity was assessed using the I² test, with outcomes graphically represented in a forest plot and a p-value of < 0.05 considered statistically significant; analyses were performed using Review Manager 5.4 (RevMan 5.4.1). >. RESULT Four observational studies were included out of 98 articles. Ten experienced surgeons participated (8 RHD and 2 LHD) and operated on 822 patients (1484 hips), divided equally between dominant and non-dominant sides, and the posterolateral approach was utilized in 80.9% of THAs. RHD surgeons operated on 1404 (94.6%) THAs. The pooled synthesis for inclination indicated no significant difference between either side [MD: 0.10 (95% CI -2.10 to 2.30, P = 0.93, I² = 91%)]. While the difference was significant for anteversion [MD: -2.37 (95% CI -3.82 to -0.93, P = 0.001, I² = 31%)]. The functional outcome was better on the dominant side [MD: 1.44 (95% CI 0.41 to 2.48, P = 0.006, I² = 0%)], and the dislocation incidence was significantly higher on the non-dominant side [OR: 0.45 (95% CI 0.25 to 0.81, P = 0.008, I² = 0%)]. CONCLUSION Surgeon handedness and whether operating on the dominant or non-dominant side could affect the acetabular cup positioning and outcomes during primary THAs, even in the hands of high-volume surgeons.
Collapse
Affiliation(s)
- Ahmed A Khalifa
- Orthopedic Department, Qena Faculty of Medicine, South Valley University, Qena, Egypt
| | - Ahmed Abdelazim Hassan
- Orthopaedic and Traumatology Department, Assiut University School of Medicine, Assuit, 71515, Egypt.
| |
Collapse
|
4
|
Aubert T, Gerard P, Galanzino G, Marmor S. In silico analysis of the patient-specific acetabular cup anteversion safe zone. Orthop Traumatol Surg Res 2024; 110:103940. [PMID: 39043498 DOI: 10.1016/j.otsr.2024.103940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 02/26/2024] [Accepted: 03/12/2024] [Indexed: 07/25/2024]
Abstract
INTRODUCTION Various computer-assisted surgical systems claim to improve the accuracy of cup placement in total hip arthroplasties after assessing spinopelvic mobility to prevent prosthetic impingement. However, no study has yet analyzed the extent of the patient-specific cup anteversion safe zones. HYPOTHESIS We hypothesized that most patients have a safe zone >10 °, except those with abnormal spinopelvic mobility, who have a much narrower safe zone. MATERIALS AND METHODS We simulated the risks of prosthetic impingement using the planned cup anteversion. The consecutive cohort included 341 patients who underwent total hip arthroplasty. Our primary endpoint was the patient-specific impingement-free zone for cup anteversion, which was then divided into four subgroups: 0 °, 1 ° to 5 °, 6 ° to 10 °, and >10 °. This data was then secondarily analyzed for abnormal spinopelvic mobility (the difference in the spinopelvic tilt [ΔSPT] from a standing to a flexed seated position >20 °). RESULTS The mean anteversion safe zone was 22.8 ° with 82.4% (281/341) of patients with a zone strictly >10 °. The mean safe zone was 8.9 ° (+/- 9 °) in patients with an ΔSPT ≥20 ° (18.2%), with 37.1% of these patients having a zone of 0 °, 16.13% a zone between 1 ° and 5 °, 8.06% a zone between 6 ° and 10 ° and 38.71% a zone >10 °. The mean safe zone was 25.9 ° (+/- 9 °) in patients with an ΔSPT <20 ° (81.8%), and the proportion of cases in each zone was 2.51%, 1.08%, 4.3%, and 92.11%, respectively (p < 0.001). CONCLUSION The safe zone for anteversion appears to be fairly wide in most patients. However, identifying patients at risk of abnormal spinopelvic mobility seems necessary to identify the two-thirds of patients with a narrow safe zone. LEVEL OF EVIDENCE IV; retrospective study.
Collapse
Affiliation(s)
- Thomas Aubert
- Orthopedic Department, Croix St Simon Hospital 125 rue d'Avron, 75020 Paris, France.
| | - Philippe Gerard
- Orthopedic Department, Croix St Simon Hospital 125 rue d'Avron, 75020 Paris, France
| | - Giacomo Galanzino
- Orthopedic Department, Croix St Simon Hospital 125 rue d'Avron, 75020 Paris, France
| | - Simon Marmor
- Orthopedic Department, Croix St Simon Hospital 125 rue d'Avron, 75020 Paris, France
| |
Collapse
|
5
|
Ong CB, Buchan GBJ, Hecht CJ, Kanaji A, Kendoff DO, Kamath AF. Robotic-assisted total hip arthroplasty utilizing a fluoroscopy-guided system produced similar cup accuracy and precision relative to a computerized tomography-based robotic platform. J Robot Surg 2024; 18:273. [PMID: 38949665 DOI: 10.1007/s11701-024-02033-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Accepted: 06/21/2024] [Indexed: 07/02/2024]
Abstract
Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.
Collapse
Affiliation(s)
- Christian B Ong
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Graham B J Buchan
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Christian J Hecht
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Arihiko Kanaji
- Department of Orthopedic Surgery, Restorative Medicine of Neuro-Musculoskeletal System, Fujita Health University Bantane Hospital, Nagoya, Aichi, Japan
| | - Daniel O Kendoff
- Chefarzt Zentrum für Orthopädie und Unfallchirurgie, HELIOS Kliniken Berlin-Buch, Schwanebecker Chaussee 25, 13125, Berlin, Germany
| | - Atul F Kamath
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| |
Collapse
|
6
|
Meermans G, Fawley D, Zagra L, Ten Broeke RHM, Johnson K, Bernard T, Thomason HC. Accuracy of cup placement compared with preoperative surgeon targets in primary total hip arthroplasty using standard instrumentation and techniques: a global, multicenter study. J Orthop Traumatol 2024; 25:25. [PMID: 38727945 PMCID: PMC11087417 DOI: 10.1186/s10195-024-00766-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 04/19/2024] [Indexed: 05/13/2024] Open
Abstract
BACKGROUND Acetabular cup positioning in total hip arthroplasty (THA) is closely related to outcomes. The literature has suggested cup parameters defined by the Lewinnek safe zone; however, the validity of such measures is in question. Several studies have raised concerns about the benefits of using the Lewinnek safe zone as a predictor of success. In this study we elected to use prospective surgeon targets as the basis for comparison to see how successful surgeons are positioning their cup using standard instruments and techniques. METHODS A prospective, global, multicenter study was conducted. Cup positioning success was defined as a composite endpoint. Both cup inclination and version needed to be within 10° of the surgeon target to be considered a success. Radiographic analysis was conducted by a third-party reviewer. RESULTS In 170 subjects, inclination, target versus actual, was 44.8° [standard deviation (SD 0.9°)] and 43.1° (SD 7.6°), respectively (p = 0.0029). Inclination was considered successful in 84.1% of cases. Mean version, target versus actual, was 19.4° (SD 3.9°) and 27.2° (SD 5.6°), respectively (p < 0.0001). Version was considered successful in 63.4% of cases, and combined position (inclination and version) was considered successful in 53.1%. CONCLUSION This study shows that with traditional methods of placing the cup intraoperatively, surgeons are only accurate 53.1% of the time compared with a predicted preoperative plan. This study suggests that the inconsistency in cup positioning based on the surgeon's planned target is potentially another important variable to consider while using a mechanical guide or in freehand techniques for cup placement in THA. TRIAL REGISTRATION This study is registered on ClinicalTrials.gov, NCT03189303.
Collapse
Affiliation(s)
- Geert Meermans
- Department of Orthopaedics, Bravis Hospital, Bergen op Zoom, Roosendaal, The Netherlands.
| | - David Fawley
- DePuy Synthes, 700 Orthopaedic Drive, Warsaw, IN, USA
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - René H M Ten Broeke
- Department of Orthopaedic Surgery, Maastricht University Medical Centre, 6202 AZ, Maastricht, The Netherlands
| | - Kory Johnson
- Orthopaedic Associates of Michigan, 555 Mid Towne St Suite 105, Grand Rapids, MI, USA
| | | | | |
Collapse
|
7
|
Zhang S, Ma M, Kong X, Zhou Y, Chen J, Chai W. Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip. INTERNATIONAL ORTHOPAEDICS 2024; 48:1189-1199. [PMID: 38358516 DOI: 10.1007/s00264-024-06115-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 01/31/2024] [Indexed: 02/16/2024]
Abstract
PURPOSES Due to the morphological diversity of deformities, technical difficulties, improperly designed components, and so on, THA remains a challenging task in dysplastic hips, especially in highly dislocated hips. The purpose of this study was to comprehensively evaluate the clinical outcomes of robot-assisted THA in patients with DDH through a large cohort study, including the precision of acetabular cup positioning, indicators of inflammatory response, indicators of muscle damage, and complications. METHODS We retrospectively analyzed patients with DDH who underwent THA in our prospectively constructed joint registry between August 2018 and August 2022. Finally, 147 manual THAs and 147 robotic-assisted THAs were included in the final analysis. Patient demographics, indicators of inflammation, indicators of muscle damage, operative time, Harris hip scores (HHS), and forgotten joint score (FJS) were recorded for analysis. The precision of the positioning of the acetabular component was assessed with plain radiographs. RESULTS In the Crowe II/III groups, the reconstructed center of rotation (COR) in the robotic-assisted group was closer to the anatomical COR with less variation than the manual group (absolute horizontal distances of COR 3.5 ± 2.8 vs. 5.4 ± 4.9 mm, p < 0.05; absolute vertical distances of COR 6.4 ± 4.1 vs. 11.7 ± 8.2 mm, p = 0.001). For all Crowe subtypes, the robotic-assisted THA significantly increased the proportion of acetabular cups located in the safety zone within 5° (all p < 0.05). Interleukin-6 and creatine kinase levels were slightly lower and significantly different in the robotic-assisted group at three days postoperatively (all p < 0.05). CONCLUSIONS Compared to the manual technique, the robot-assisted technique improved the precision and reproducibility of acetabular component positioning, particularly in DDH patients with Crowe types II/III. The robotic-assisted technique did not increase operative time, bleeding, complications, or revision rates, and had a slighter early inflammatory response and muscle damage.
Collapse
Affiliation(s)
- Shuai Zhang
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China
- Department of Orthopedics, the 969th Hospital of the PLA joint Logisitcs Support Force, No. 51 Aimin street, Xincheng District, Huhehaote, China
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China
| | - Mingyang Ma
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| | - Xiangpeng Kong
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China
| | - Yonggang Zhou
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| | - Jiying Chen
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| | - Wei Chai
- Senior Department of Orthopedics, the Forth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Haidian District, Beijing, China.
- National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, No. 28 Fuxing Road, Haidian District, Beijing, China.
| |
Collapse
|
8
|
Yi N, Yuan H, Xu N, Liu R, Wang Y, Zhuang C. Digital protractor as an intraoperative guide to cup anteversion in total hip arthroplasty. BMC Surg 2024; 24:27. [PMID: 38238716 PMCID: PMC10795370 DOI: 10.1186/s12893-023-02297-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Accepted: 12/15/2023] [Indexed: 01/22/2024] Open
Abstract
INTRODUCTION To explore if digital protractor could guide the anteversion of acetabular cup during primary THA and make it consistent with preoperative. METHODS We retrospectively reviewed 172 cases of primary THA with direct anterior approach (DAA) over 2 years. The anteversion of acetabular cup were measured from computed tomography (CT) scan preoperative and de-identified plain radiographs postoperative by two blinded investigators who were not involved in the surgery. The effect of the digital protractor on the anteversion was determined using regression analysis. RESULTS The mean anteversion for the THAs in digital protractor group was 15.5°and 21.4°in control group (P < 0.01). The mean anteversion bias for the THAs in digital protractor group was 1.59° and 6.63° in control group (P < 0.01).Regression analysis identified a 10.7% difference in anteversion due to the use of digital protractor (P < 0.01), and THAs performed without digital protractor were six times more likely to result in anteversion of > 25°. The correlation coefficient for the interobserver reliability of the measurement of the two investigators was 0.94. CONCLUSION The digital protractor is a practical tool in the DAA for THA to determine the anteversion of the acetabular prosthesis.
Collapse
Affiliation(s)
- Ning Yi
- Graduate School of Dalian Medical University, Dalian, China
| | - Hang Yuan
- Bengbu Medical College, Bengbu, China
| | - Nanwei Xu
- Department of Orthopedics, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou, China
| | - Ruiping Liu
- Department of Orthopedics, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou, China
| | - Yuji Wang
- Department of Orthopedics, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou, China
| | - Chao Zhuang
- Department of Orthopedics, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou, China.
| |
Collapse
|
9
|
LaCour M, Nguyen TD, Nachtrab J, Bonnin M, Komistek R. Alignment and mechanics evaluation for a compaction broach stem versus a blade style proximal press fit stem using 3-Dimensional planning. J Biomech 2024; 163:111950. [PMID: 38237494 DOI: 10.1016/j.jbiomech.2024.111950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 11/06/2023] [Accepted: 01/10/2024] [Indexed: 02/10/2024]
Abstract
Three-dimensional (3D) preoperative planning tools can be used to help plan and compare component alignment scenarios for different total hip arthroplasty systems to ultimately improve postoperative outcomes and patient satisfaction. The objective of this study is to use 3D preoperative planning tools based on patient-specific bone models to compare two different stem designs, specifically a compaction broach stem and a proximal press fit stem. The planner uses patient-specific proximal femoral bone morphology to suggest a specific implant size and placement. The planner then allows for preoperative predictions of component head positioning, stem fit within the canal, and potential cortical bone reaming that must be done, as well as postoperative predictions of stability and mechanics. The stems were evaluated to determine the accuracy of stem placement, the theoretical volumetric bone removal/reaming required to achieve a desired fit, and the associated postoperative mechanics. This study demonstrated that there was a difference in component alignment and predicted postoperative mechanics between a compaction broach stem and a press fit stem, with the compaction broach stem allowing for more accurate alignment with less required bone removal, resulting in improved postoperative stability and mechanics. This study also demonstrated that much of the stem misalignment for both systems occurred in the anterior/posterior direction. Overall, 3D preoperative planning offers significant benefits and novel intraoperative insight, and the industry should continue to enhance their THA preoperative planning tools.
Collapse
|
10
|
Luu K, Nishioka ST, Lawton DRY, Unebasami E, Andrews SN, Nakasone CK. Influence of obesity and intra-operative imaging guidance technology on acetabular cup positioning in total hip arthroplasty. Arch Orthop Trauma Surg 2023; 143:6857-6863. [PMID: 37270739 DOI: 10.1007/s00402-023-04922-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 05/21/2023] [Indexed: 06/05/2023]
Abstract
BACKGROUND Accuracy of acetabular cup positioning during total hip arthroplasty (THA) can be improved with intra-operative imaging but may be influenced by body mass index (BMI). This study assessed the influence of BMI (kg/m2) on cup accuracy when using intra-operative fluoroscopy (IF) alone or supplemented with a commercial product. METHODS This retrospective review included four consecutive cohorts of patients having undergone anterior approach THA with IF alone (2011-2015), IF and Overlay (2015-2016) (Radlink Inc., Los Angeles, CA), IF and Grid (2017-2018) (HipGrid Drone™, OrthoGrid Systems Inc., Salt Lake City, UT) and IF and Digital (2018-2020) (OrthoGrid Phantom®, OrthoGrid Systems, Inc., Salt Lake City, UT). Component placement accuracy was measured on 6-week post-operative weight bearing radiographs and compared between four BMI patient groups (BMI ≤ 25, 25 < BMI ≤ 30, 30 < BMI ≤ 35, and 35 < BMI). Total fluoroscopy times were also recorded directly from the fluoroscopy unit. RESULTS Abduction angle significantly increased as BMI increased (p = 0.003) with IF alone but no difference was present in groups with guidance technology. Anteversion was significantly different between BMI groups for IF alone (p = 0.028) and Grid (p = 0.027) but was not different in Overlay (p = 0.107) or Digital (p = 0.210). Fluoroscopy time was significantly different between BMI categories for IF alone (p = 0.005) and Grid (p = 0.018) but was not different in Overlay (p = 0.444) or Digital (p = 0.170). CONCLUSION Morbid obesity (BMI > 35) increases risk for malpositioning of acetabular cups and increases surgical time with IF alone or the Grid. Additional IF guidance technology (Overlay or Digital) increased cup positioning accuracy without decreasing surgical efficiency.
Collapse
Affiliation(s)
- Kayti Luu
- John A Burns School of Medicine, 651 Ilalo Street, Honolulu, HI, 96813, USA
| | - Scott T Nishioka
- John A Burns School of Medicine, 651 Ilalo Street, Honolulu, HI, 96813, USA
| | - Dylan R Y Lawton
- John A Burns School of Medicine, 651 Ilalo Street, Honolulu, HI, 96813, USA
| | - Emily Unebasami
- Department of Orthopedic Surgery, Straub Medical Center, 888 South King Street, Honolulu, HI, 96818, USA
| | - Samantha N Andrews
- Department of Surgery, University of Hawai'I, John A Burns School of Medicine, 1356 Lusitana Street, Honolulu, HI, 96813, USA
- Department of Orthopedic Surgery, Straub Medical Center, 888 South King Street, Honolulu, HI, 96818, USA
| | - Cass K Nakasone
- Department of Surgery, University of Hawai'I, John A Burns School of Medicine, 1356 Lusitana Street, Honolulu, HI, 96813, USA.
- Department of Orthopedic Surgery, Straub Medical Center, 888 South King Street, Honolulu, HI, 96818, USA.
| |
Collapse
|
11
|
Lu H, Xiao Q, Xu H, Yan T, Zhou Z. Robotic arm-assisted total hip arthroplasty for preoperative planning and intraoperative decision-making. J Orthop Surg Res 2023; 18:608. [PMID: 37605281 PMCID: PMC10440908 DOI: 10.1186/s13018-023-04095-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 08/11/2023] [Indexed: 08/23/2023] Open
Abstract
AIMS This article aimed to explore the efficacy of robotic arm-assisted total hip arthroplasty (THA) in improving preoperative planning and intraoperative decision-making. METHODS In this single-center, prospective, randomized clinical controlled trial, 60 patients were randomly divided into two groups: conventional THA (cTHA) and robotic arm-assisted THA (rTHA). The rTHA underwent procedures using a robot-assisted surgical system, which generated three-dimensional models to determine the most appropriate prosthesis size and position. The standard process of replacement was executed in cTHA planned preoperatively via X-ray by experienced surgeons. Differences between predicted and actual prosthetic size, prosthetic position, and leg length were evaluated. RESULTS Sixty patients were included in the study, but one patient was not allocated due to anemia. No significant preoperative baseline data difference was found between the two groups. The actual versus predicted implantation size of both groups revealed that 27/30 (90.0%) in the rTHA group and 25/29 (86.2%) in the cTHA group experienced complete coincidence. The coincidence rate for the femoral stem was higher in the rTHA group (83.3%) than that in the cTHA group (62.7%). Between the actual and predicted rTHA, the difference in anteversion/inclination degree (< 6°) was largely dispersed, while cTHA was more evenly distributed in degree (< 9°). The differences in leg length between the surgical side and contralateral side showed a significant deviation when comparing the two groups (P = 0.003), with 0.281 (- 4.17 to 3.32) mm in rTHA and 3.79 (1.45-6.42) mm in cTHA. CONCLUSION Robotic arm-assisted total hip arthroplasty can be valuable for preoperative planning and intraoperative decision-making.
Collapse
Affiliation(s)
- Hanpeng Lu
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Road, Wuhou District, Chengdu, 610041, Si Chuan, People's Republic of China
| | - Qiang Xiao
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Road, Wuhou District, Chengdu, 610041, Si Chuan, People's Republic of China
| | - Hong Xu
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Road, Wuhou District, Chengdu, 610041, Si Chuan, People's Republic of China
| | - Tingfang Yan
- Yuanhua Intelligent Technology Co., Ltd, Shenzhen, People's Republic of China
| | - Zongke Zhou
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No. 37, Guoxue Road, Wuhou District, Chengdu, 610041, Si Chuan, People's Republic of China.
| |
Collapse
|
12
|
Bradley MP, Muir JM, Wang S. Computer-Assisted Navigation Accurately Delivers Preoperative Targets for Acetabular Component Orientation During Direct Anterior Approach Total Hip Arthroplasty. Orthopedics 2023; 46:218-223. [PMID: 36719422 DOI: 10.3928/01477447-20230125-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Despite its success, total hip arthroplasty (THA) remains associated with potentially significant complications associated with component malposition. Preoperative planning can mitigate some of these potential concerns; however, the accurate intraoperative delivery of preoperative targets can be challenging. Computer-assisted navigation may assist with intraoperative target delivery, although the integration of these two technologies is relatively uncommon. We retrospectively reviewed cases of THA planned with a computed tomography-based preoperative planning software and performed with the use of an imageless, computer-assisted navigation system. Postoperative acetabular component orientation from radiographs was compared with preoperative targets and intraoperative navigation measurements. A total of 76 patients were included in the analysis. The mean anteversion target (20.0°±3.1°) did not differ significantly from the mean intraoperative navigation measurement (20.5°±3.3°; P=.30; mean difference, 2.2°±2.3°). The mean radiographic measurement (26.6°±6.5°) differed from the target by a mean of 7.5°±6.1° (P<.001). The mean inclination target (38.4°±1.9°) did not differ significantly from the mean intra-operative measurement (38.0°±1.5°; P=.20; mean difference, 1.3°±1.7°) but differed from the radiographic measurement by a mean of 5.2°±4.2° (41.8°±5.6°; P<.001). No adverse events were reported in the 90-day period following the index procedure. Our study demonstrated that an imageless navigation system can accurately deliver computed tomography-derived preoperative targets for acetabular component orientation. Differences noted on radiographs may be due to the difference in patient positioning for the postoperative imaging (standing) as compared with preoperative imaging or surgery itself (supine). [Orthopedics. 2023;46(4):218-223.].
Collapse
|
13
|
Baghdadi J, Alkhateeb S, Roth A, Jäger M, Alkhateeb S, Landgraeber S, Serong S, Haversath M, vonWasen A, Windhagen H, Flörkemeier T, Budde S, Kubilay J, Noll Y, Delank KS, Baghdadi J, Willburger R, Dücker M, Wilke A, Hütter F, Jäger M. Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up. Arch Orthop Trauma Surg 2023; 143:1679-1688. [PMID: 35397656 PMCID: PMC9957849 DOI: 10.1007/s00402-022-04424-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 03/10/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Aseptic loosening remains a challenging problem after total hip arthroplasty. Accurate cup placement and supplementation of antioxidants in acetabular liners might reduce material failure rates. The aim of this study is to assess the effect of the cup position on the wear behaviour of UHMWPE-XE and UHMWPE-X liners in vivo using virtual radiographs. METHODS We conducted a prospective, randomized, controlled, multicenter trial. Clinical data of 372 probands were analyzed. Anteroposterior pelvic X-rays of 324 patients immediately postoperatively and after 1 and 5 years were evaluated by the RayMatch® analysis software regarding cup position and wear behaviour. RESULTS Mean cup anteversion was 20.3° (± 7.4) and inclination was 41.9° (± 7.0) postoperatively. 62.3% of all patients had an anteversion and inclination within the Lewinnek safe zone. Anterior and anterolateral approaches led to significantly higher cup anteversion compared to lateral approaches (27.3° ± 5.5; 20.9° ± 7.2; 17.5° ± 6.6; p < 0.001 and p = 0.001, respectively). Mean anteversion increased to 24.6° (± 8.0) after 1 year (p < 0.001). Only one revision occurred because of implant dislocation. Wear rates from UHMWPE-X and UHMWPE-XE did not differ significantly. Anteversion angles ≥ 25° correlated to increased polyethylene wear (23.7 µm/year ± 12.8 vs. 31.1 µm/year ± 22.8, p = 0.012) and this was amplified when inclination angles were ≥ 50° (23.6 µm/year ± 12.8 vs. 38.0 µm/year ± 22.7, p = 0.062). CONCLUSION Anterior approaches lead to the highest inaccuracy of cup placement, but cup positioning outside the Lewinnek safe zone does not necessarily cause higher dislocation rates. Moreover, mean anteversion increased by approximately four degrees within the first year after operation, which is expected to be functional due to a regularization of pelvic tilt after intervention. Mid-term wear rates of UHMWPE-X and UHMWPE-XE liners are comparable, but steep cup positions lead to significantly increased polyethylene wear. In summary, a re-evaluation of target zones for intraoperative cup positioning might be considered. In the long-term reduced oxidative embrittlement could lead to superior wear behaviour of vitamin E-blended liners.
Collapse
Affiliation(s)
- Josef Baghdadi
- Department of Orthopedics, Trauma, and Reconstructive Surgery, University Hospital Halle (Saale), Halle (Saale), Germany.
| | - Shareef Alkhateeb
- Department of Orthopedics, Trauma and Reconstructive Surgery, Marienhospital Mülheim an Der Ruhr, Chair of Orthopedics and Trauma Surgery, University of Duisburg–Essen, Essen, Germany
| | | | | | - Marcus Jäger
- Department of Orthopedics, Trauma and Reconstructive Surgery, Marienhospital Mülheim an Der Ruhr, Chair of Orthopedics and Trauma Surgery, University of Duisburg–Essen, Essen, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Saracco M, Fidanza A, Necozione S, Maccauro G, Logroscino G. Could Short Stems THA Be a Good Bone-Saving Option Even in Obese Patients? J Clin Med 2022; 11:jcm11237114. [PMID: 36498685 PMCID: PMC9739638 DOI: 10.3390/jcm11237114] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/23/2022] [Accepted: 11/26/2022] [Indexed: 12/03/2022] Open
Abstract
Short femoral stems, with preservation of the femoral bone stock, are commonly used in recent years for hip replacement in younger and more active patients. Obesity is increasingly spreading even in the younger population. The aim of this case-series study is to evaluate short stems compared to traditional hip prostheses in the obese population. A total of 77 consecutive patients with a BMI greater than or equal to 30 Kg/m2 were enrolled in this prospective study and were divided into two groups: 49 patients have been implanted with short stems while 28 patients were implanted with traditional stems. All the patients were treated for primary osteoarthritis or avascular necrosis and all the stems were implanted by the same surgeon using a posterior approach. Clinical (Harris Hip Score—HHS, Western Ontario and McMaster Universities Osteoarthritis Index—WOMAC, visual analogue scale—VAS, 12-item Short Form Health Survey—SF-12) and radiographic outcomes were recorded. Radiological evaluations were carried out by three different blinded surgeons. A statistical analysis was performed (chi-square, t-test, Wilcoxon Rank Sum Test, 2-factor ANOVA). At a mean follow-up of 42.6 months both groups showed a marked improvement in pain and in the clinical scores between pre- and post-surgical procedures (p < 0.05) with no significant differences between the two groups at last follow-up (p > 0.05). The radiological evaluations, with high concordance correlation between the three blinded surgeons (ICC consistently >0.80), showed good positioning and osseointegration in all cases, with no significant differences in the restoration of the joint geometry and complications. No revisions were recorded during the follow-up period. In conclusion, short stems appear to be a good option for bone preservation even in obese patients, showing comparable results to traditional implants.
Collapse
Affiliation(s)
- Michela Saracco
- “A. Gemelli” IRCCS University Hospital Foundation, Catholic University of Sacred Heart, 00168 Rome, Italy
- Department of Orthopaedics, ASL Napoli 2 Nord, 80027 Naples, Italy
| | - Andrea Fidanza
- Department Life, Health and Environmental Sciences—Mininvasive Orthopaedic Surgery, University of L’Aquila, 67100 L’Aquila, Italy
- Correspondence:
| | - Stefano Necozione
- Department Life, Health and Environmental Sciences—Unit of Epidemiolody, University of L’Aquila, 67100 L’Aquila, Italy
| | - Giulio Maccauro
- “A. Gemelli” IRCCS University Hospital Foundation, Catholic University of Sacred Heart, 00168 Rome, Italy
| | - Giandomenico Logroscino
- Department Life, Health and Environmental Sciences—Mininvasive Orthopaedic Surgery, University of L’Aquila, 67100 L’Aquila, Italy
| |
Collapse
|
15
|
A laser guide technique: a novel method for accurate acetabular cup alignment in total hip arthroplasty. Sci Rep 2022; 12:18247. [PMID: 36309552 PMCID: PMC9617895 DOI: 10.1038/s41598-022-21975-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Accepted: 10/07/2022] [Indexed: 12/31/2022] Open
Abstract
For accurate cup alignment without navigation in total hip arthroplasty (THA), we developed a "laser guide technique." The major purposes of this paper are to introduce the technique and compare its accuracy with a conventional manual technique. As a clinical outcome, the dislocation rate was reviewed. Our laser guide technique, which includes preoperative postural adjustment and intraoperative angular reference, has been detailed in the manuscript. 599 hips in 523 patients who underwent primary THA with piriformis-sparing posterolateral approach in April 2010-March 2016 were reviewed. Patients were divided into three groups: conventional group (135 hips), laser guide group (80 hips), and laser + radiographic alignment guide group (384 hips). Radiographic inclination (RI) and radiographic anteversion (RA) errors were evaluated. The dislocation rate was reviewed in 540 hips in 476 patients who were followed up > 2 years postoperatively. Absolute values of the RI/RA error in the three groups were 5.3° ± 4.0°/6.5° ± 4.5°, 4.0° ± 2.8°/4.9° ± 4.4°, and 3.3° ± 2.6°/3.6° ± 2.8°, respectively, indicating substantially enhanced accuracy with laser and radiographic alignment guide. The dislocation rates were 2.5% (3/119) and 0.2% (1/421) in the conventional and laser groups, respectively. Our novel laser guide technique considerably enhanced cup alignment accuracy, suggesting its potential applicability for THA in the lateral decubitus position.
Collapse
|
16
|
Wessling M, Gebert C, Hakenes T, Dudda M, Hardes J, Frieler S, Jeys LM, Hanusrichter Y. Reconstruction of Paprosky III defects with custom-made implants: do we get them in the correct position? : short-term radiological results. Bone Joint J 2022; 104-B:1110-1117. [PMID: 36177641 DOI: 10.1302/0301-620x.104b10.bjj-2022-0508.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants. METHODS A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up. RESULTS Mean CT defined discrepancy (Δ) between planned and achieved AV and IC was 4.5° (SD 3°; 0° to 12°) and 4° (SD 3.5°; 1° to 12°), respectively. Malpositioning (Δ > 10°) occurred in five hips (10.6%). Native COR reconstruction was planned in 42 cases (93%), and the mean 3D deviation vector was 15.5 mm (SD 8.5; 4 to 35). There was no significant influence in malpositioning found for femoral stem retention, surgical approach, or fixation method. CONCLUSION At short-term follow-up, we found that PPR offers a viable solution for rTHA in cases with massive acetabular bone loss, as highly accurate positioning can be accomplished with meticulous planning, achieving anatomical reconstruction. Accuracy of achieved placement contributed to reduced complications with no injury to vital structures by screw fixation.Cite this article: Bone Joint J 2022;104-B(10):1110-1117.
Collapse
Affiliation(s)
- Martin Wessling
- Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, Wetter, Germany.,Center for Musculoskeletal Surgery, University Hospital of Essen, Essen, Germany
| | - Carsten Gebert
- Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, Wetter, Germany.,Department of Orthopedics and Tumor Orthopedics, Muenster University Hospital, Muenster, Germany
| | - Tilmann Hakenes
- Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, Wetter, Germany
| | - Marcel Dudda
- Center for Musculoskeletal Surgery, University Hospital of Essen, Essen, Germany
| | - Jendrik Hardes
- Center for Musculoskeletal Surgery, University Hospital of Essen, Essen, Germany.,Department of Trauma Surgery, University Hospital Essen, Essen, Germany
| | - Sven Frieler
- Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, Wetter, Germany.,Seattle Science Foundation, Seattle, Washington, USA.,Department of Trauma and Orthopedic Surgery, BG University Hospital Bergmannsheil, Ruhr University Bochum, Bochum, Germany
| | - Lee M Jeys
- Oncology Department, The Royal Orthopaedic Hospital, Birmingham, UK.,Faculty of Health Sciences, Aston University, Birmingham, UK
| | - Yannik Hanusrichter
- Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, Wetter, Germany.,Center for Musculoskeletal Surgery, University Hospital of Essen, Essen, Germany.,Department of Trauma and Orthopedic Surgery, BG University Hospital Bergmannsheil, Ruhr University Bochum, Bochum, Germany
| |
Collapse
|
17
|
ÇATALTEPE A. The length of distal skin incision of the postero-lateral approach affects the cup inclination during the total hip arthroplasty. JOURNAL OF HEALTH SCIENCES AND MEDICINE 2022. [DOI: 10.32322/jhsm.1071852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Aim: The primary aim of the study was to determine whether the length of the distal skin incision of the posterolateral approach affects the cup inclination during total hip arthroplasty (THA).
Material and Method: In this study, a cohort of 71 consecutive patients who performed between January 2017 and December 2021 with unilateral THA using a posterolateral approach was retrospectively assessed. Two groups were formed according to acetabular cup inclination with normal anteversion angle. There were 56 hips in the inside group and 17 in the outside group. A curvilinear skin incision of around 13 cm was performed. Component position evaluation was carried out through a radiographic assessment of the acetabular component on an anteroposterior pelvis radiograph. The rate of an outlier was compared between groups according to the safe zone defined as 30° to 50° of inclination and 5° to 25° of anteversion, which was described by Lewinnek et al.
Results: No significant difference in the average total incision length was found between the two groups (p=0.207). While the average distal incision length was 7.91±0.62 cm (range, 6.8-9 cm) in the inside group and 6.37±0.21 cm (range, 6-6.7 cm) in the outside group. According to ROC analysis, a patient with ≤6.7 cm of the distal length of incision (DLI) was 5.71 times more likely to be outside than a patient with >6.7 cm of DLI. Seventeen hips (23.3%) were found outside the safe range. Substantial differences were observed regarding radiographic cup inclination between the two groups (p=0.0001). In the inside group, the average cup inclination was 44.11°±3.44° (range, 37°-50°), whereas, in the outside group, it was 55.41°±2.5° (range, 52°-59°). However, there were no significant differences in the average radiographic cup anteversion between the two groups (p=0.960). Although 11 of 17 (64.5%) patients were classified as obese (BMI ≥30) in the outside group experienced higher rates of inaccurate cup orientation, logistic regression analysis showed that the individual effects of obesity on the occurrence of the inaccurate cup position were not observed (p=0.884). One posterior hip dislocation occurred after one month postoperative in the outside group.
Conclusions: Longer distal portion of the skin incision of the posterolateral approach should be performed to achieve optimal operative inclination angles of the acetabular cup during THA. The surgeon must have no hesitation in extending the distal skin incision when adopting the posterolateral approach.
Collapse
|
18
|
Meermans G, Grammatopoulos G, Innmann M, Beverland D. Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics. EFORT Open Rev 2022; 7:365-374. [PMID: 35638598 PMCID: PMC9257731 DOI: 10.1530/eor-22-0025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Acetabular component orientation and position are important factors in the short- and long-term outcomes of total hip arthroplasty. Different definitions of inclination and anteversion are used in the orthopaedic literature and surgeons should be aware of these differences and understand their relationships. There is no universal safe zone. Preoperative planning should be used to determine the optimum position and orientation of the cup and assess spinopelvic characteristics to adjust cup orientation accordingly. A peripheral reaming technique leads to a more accurate restoration of the centre of rotation with less variability compared with a standard reaming technique. Several intraoperative landmarks can be used to control the version of the cup, the most commonly used and studied is the transverse acetabular ligament. The use of an inclinometer reduces the variability associated with the use of freehand or mechanical alignment guides.
Collapse
|
19
|
Zinner M, Schroeder L, Pumilia CA, Lee EK, Martin G. THA with Use of Patient-Specific Resurfacing Jigs and a Novel Customized Implant Design. JBJS Rev 2022; 10:01874474-202205000-00008. [PMID: 36995410 DOI: 10.2106/jbjs.rvw.21.00078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
» Conventional total hip arthroplasty (THA) largely remains an unguided procedure dependent on the ability and experience of the surgeon. New technologies, such as patient-specific instrumentation and robotics, have shown promising results in improving implant positioning, which has the potential to improve patient outcomes. » The use of off-the-shelf (OTS) implant designs, however, limits the success of the technological advances since they are unable to recreate the native anatomy of the joint. The inability to restore femoral offset and version or the presence of implant-related leg-length discrepancies often lead to suboptimal surgical results that increase the risk of dislocation, fractures, and component wear, compromising postoperative functional outcomes and implant longevity. » A customized THA system, whereby the femoral stem is designed to restore patient anatomy, has recently been introduced. The THA system uses computed tomography (CT)-derived 3D imaging to create a custom stem, patient-specific component placement, and patient-specific instrumentation that matches the patient's native anatomy. » The purpose of this article is to provide information on the design and manufacturing process of this new THA implant, to illustrate the associated preoperative planning, and to describe the surgical technique; 3 surgical cases are presented.
Collapse
Affiliation(s)
- Matthew Zinner
- Charles E. Schmidt College of Medicine, Boca Raton, Florida
| | - Lennart Schroeder
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany
| | - Cyrus A Pumilia
- College of Medicine, University of Central Florida, Orlando, Florida
| | - Eric K Lee
- Department of Orthopedic Surgery, Personalized Orthopaedics of the Palm Beaches, Boynton Beach, Florida
| | - Gregory Martin
- College of Medicine, University of Central Florida, Orlando, Florida
- Department of Orthopedic Surgery, Personalized Orthopaedics of the Palm Beaches, Boynton Beach, Florida
- University of Miami Leonard M. Miller School of Medicine, Miami, Florida
| |
Collapse
|
20
|
Okutani Y, Kataoka M, Harada H, Kunishita T, Ryoki H, Arai R. A high body mass index tilts the pelvis caudally in the lateral decubitus position for total hip arthroplasty. Hip Int 2022; 33:371-376. [PMID: 35311359 DOI: 10.1177/11207000221084627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Accurate cup placement is essential for obtaining excellent outcomes in total hip arthroplasty (THA). We evaluated the pelvic lateral tilt of the patient (which affects the incline of the acetabular cup in THA) and investigated the factors affecting it. METHODS We reviewed the medical records of THA procedures performed at our hospital between October 2015 and January 2021 for which an anteroposterior pelvic radiograph was always taken preoperatively once the patient was placed in the lateral decubitus position. These radiographs were used to measure the lateral pelvic tilt in each case. We analysed whether patient factors (sex, body mass index [BMI], range of motion of abduction or adduction in both hips, surgical history of both hips, and lumbar Cobb angle) influenced the tilt. RESULTS We reviewed 363 cases (341 primary, 22 revision). The mean pelvic lateral tilt was 4.1°, and the operated hip was located on the caudal side compared to the unoperated hip. Statistical analyses revealed that the patient BMI and surgical history of the operated and unoperated hips significantly influenced tilt. CONCLUSIONS The pelvis in the lateral decubitus position leaned 4.1° to the caudal side, most commonly due to a high BMI. Surgeons should consider this when performing acetabular cup implantation in THA.
Collapse
Affiliation(s)
- Yuki Okutani
- Department of Orthopaedic Surgery, Kyoto Katsura Hospital, Kyoto, Japan
| | - Masanao Kataoka
- Department of Orthopaedic Surgery, Kyoto Katsura Hospital, Kyoto, Japan
| | - Hideto Harada
- Department of Orthopaedic Surgery, Kyoto Katsura Hospital, Kyoto, Japan
| | | | - Hayato Ryoki
- Department of Orthopaedic Surgery, Kyoto Katsura Hospital, Kyoto, Japan
| | - Ryuzo Arai
- Department of Orthopaedic Surgery, Kyoto Katsura Hospital, Kyoto, Japan
| |
Collapse
|
21
|
Zhou Y, Shao H, Huang Y, Deng W, Yang D, Bian T. Does robotic assisted technology improve the accuracy of acetabular component positioning in patients with DDH? J Orthop Surg (Hong Kong) 2021; 29:23094990211025325. [PMID: 34308688 DOI: 10.1177/23094990211025325] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Accurate positioning of the acetabular component is key in performing total hip arthroplasty (THA). However, reconstruction of the acetabulum in the setting of developmental dysplasia of the hip (DDH) is a challenge. Robotic assisted THA has the potential to improve the accuracy of implantation of the acetabular cup in cases with DDH. The purpose of this study was to assess whether robotic technology improves the accuracy of acetabular component positioning in patients with DDH. MATERIAL AND METHODS We included 59 THAs using robotic assisted technology from June 2019 to January 2020 as the study group. These were compared to conventional THAs without robotic technology after control for age, gender, body mass index (BMI), Crowe type and operation date. Radiographic measurements were taken by 2 blinded orthopaedic residents. The percentage of hips within the Lewinnek and Collanan safe zones were calculated, along with acetabular rotation centers for the "target zone." Surgical time and perioperative bleeding were also compared between both groups. RESULTS One patient suffered dislocation in conventional group while no dislocation occurred in robotic group. The acetabular components of the robotic assisted group had more cases located within the Lewinnek (p = 0.013) and Collanan (p = 0.008) safe zones than conventional group (94.9% vs 79.7% and 74.6% vs 50.8%). There were 7 cases in conventional group and 4 cases in robotic group that had more lateral or more superior rotational centers of THA, but did not reach statistical significance (p = 0.342). No statistical difference was detected between groups with regards to blood loss (p = 0.098) and surgical time (p = 0.602). CONCLUSION Robot assisted technology can assist surgeons with implanting acetabular cups more in Lewinnek and Callanan safe zone than conventional techniques without additional blood loss and surgical time. LEVEL OF EVIDENCE Therapeutic Level Ⅲ.
Collapse
Affiliation(s)
- Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Hongyi Shao
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yong Huang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Wang Deng
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Dejin Yang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Tao Bian
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| |
Collapse
|
22
|
Accuracy of acetabular cup placement positively correlates with level of training. INTERNATIONAL ORTHOPAEDICS 2021; 45:2797-2804. [PMID: 34406431 DOI: 10.1007/s00264-021-05165-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 07/20/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Accurate acetabular component placement may reduce the risk of complication after total hip arthroplasty (THA). While surgeon experience and volume may reduce outliers, little is known how cup positioning accuracy and consistency relates to level of training (resident, fellow, attending) and whether trainee level impacts the magnitude and direction of cup placement errors. METHODS Ninety patients undergoing posterolateral computer-assisted navigation THA were included for analysis. All surgery was performed by two fellowship-trained orthopaedic surgeons and assisted by a trainee (orthopedic resident (PGY 1-5) or fellow in adult reconstruction). In order to determine accuracy of cup placement in trainees and attendings, we used computer navigation to determine freehand cup placement by the trainee, then by the attending surgeon. Final cup inclination and version were determined and recorded by computer-assisted surgical navigation. Comparison of consistency in cup inclination and anteversion was made on values obtained by residents, fellows, and attendings and final values provided by the navigation system. In addition, to assess the role of training and repetition, acetabular cup inclination and version were compared between fellows during the first half and the second half of their training year. All comparisons were performed with the Student t-test except for comparison of rate of deviation from the safe zone, which were performed with the chi-square test. The level of significance was defined as p values ≤ 0.05 with 95% confidence interval, and trend toward significance was defined as p values ≤ 0.1. RESULTS Inclination deviation from the final position and cup version deviation from the final position were statistically significant between resident vs attendings (p < 0.001 (inclination), p < 0.001 (version)), fellow vs attendings (p < 0.001 (inclination), p < 0.001 (version)), and all trainee vs attendings (p < 0.001 (inclination), p < 0.001 (version)). In all comparisons, the attending surgeons placed the cup closer to the final cup position than both resident and fellows. Proportion of inclination deviation from the safe zone of residents was significantly higher than of attendings (p < 0.001) but no significant difference was observed between fellows and attending (p = 1.00). Compared to residents, fellows demonstrated lower proportion of inclination deviation from the safe zone of 3.3% vs 23.3% for fellows vs residents (p = 0.002) and tended to implant the cups in a more horizontal position (45.6 ± 6.6° [SD] and 42.7 ± 4.3°, respectively, p = 0.04). Compared to fellow, residents tended to implant the cup in a more anteverted position than the final cup version (9.6 ± 6.7° and 6.74 ± 5.6° [SD], p = 0.034). There was no statistically significant difference in cup position between attendings' free-hand and final (computer assisted) cup placement. CONCLUSION Accurate and consistent acetabular cup placement improves with level of training. Accurate and consistent acetabular cup version is harder to master as compared to acetabular cup inclination.
Collapse
|
23
|
Bechler U, Springer B, Rueckl K, Rolvien T, Boettner F. Can a simple iPad app improve C-arm based component position in anterior THA? Arch Orthop Trauma Surg 2021; 141:1401-1409. [PMID: 33582865 DOI: 10.1007/s00402-021-03807-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 01/25/2021] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Correct acetabular component positioning improves hip biomechanics, impingement free range of motion and may lead to a reduced risk of postoperative dislocation. The C-arm is a simple and cost-effective tool for THA in a supine position, however, evaluation of the images can be challenging due to parallax. The current study aimed to investigate whether a software app-based measurement technique can control acetabular component position and leg length in anterior THA. MATERIALS AND METHODS Ninety-three patients with end-stage osteoarthritis aged 65.2 ± 9.6 years (range 30-86 years) were included in this prospective study. All patients underwent direct anterior THA using a Hana orthopedic surgery table. C-arm imaging and an iPad software app were used to determine intraoperative acetabular anteversion, inclination and leg length discrepancy. The app provides a measuring tool that is applied to intraoperative c-arm images. The intraoperative measurements were compared to the measurements of standard postoperative AP-pelvis radiographs. RESULTS Intraoperative software app-based anteversion measurements averaged 20.5° (range 16.0° to 24.0°) compared to 20.9° (range 14.7° to 25.6°) postoperatively. Mean intraoperative inclination was 40.5° (range 35° to 48°) compared to postoperative 40.7° (range 35° to 49°). Mean intraoperative leg length discrepancy was 0.9 mm (range - 4-5 mm) compared to postoperative 0.6 mm (range - 5-6 mm). A strong Pearson's correlation was observed between the intraoperative and postoperative measurements for anteversion (r = .701; P < .0001), inclination (r = .816; P < .0001) and leg length discrepancy (r = .542; P < .0001). CONCLUSIONS The software app used in the current study allowed for a simple and accurate measurement of intraoperative cup position and leg length in direct anterior THA.
Collapse
Affiliation(s)
- Ulrich Bechler
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.,Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251, Hamburg, Germany
| | - Bernhard Springer
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Kilian Rueckl
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Tim Rolvien
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251, Hamburg, Germany
| | - Friedrich Boettner
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| |
Collapse
|
24
|
The Cost of Robot-assisted Total Hip Arthroplasty: Comparing Safety and Hospital Charges to Conventional Total Hip Arthroplasty. J Am Acad Orthop Surg 2021; 29:609-615. [PMID: 32991384 DOI: 10.5435/jaaos-d-20-00715] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 08/14/2020] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION Utilization of robotic assistance is increasing for total hip arthroplasty (THA). However, few studies have directly examined the efficacy of this technique at reducing complications. This research aims to compare the rates of perioperative complications of robotic-assisted THA (RA-THA) with conventional THA (C-THA). METHODS This study screened more than 35 million hospital discharges between 2010 to 2014 using the National Inpatient Sample. The International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) procedure codes were used to identify 292,836 patients who underwent C-THA (ICD 81.51) and 946 patients who underwent RA-THA (ICD 81.51 and ICD 17.41, 17.49). Perioperative complications were identified using ICD-9-CM diagnosis codes. Patient mortality was determined using the Uniform Bill patient disposition. The RA-THA cohort was statistically matched 1:1 to C-THA about patient age, sex, race, comorbidities, hospital type, and calendar year. Mean cost and length of stay (LOS) for each cohort were calculated and compared using the Kruskal-Wallis H test. Logistic regression was used to compare the risks of major and minor complications between the cohorts. RESULTS We matched 758 (80.13%) RA-THA patients with 758 patients who underwent C-THA. No patient in our sample died. When compared with the conventional group, multivariate analysis revealed that the risk of major complications was similar in RA-THA patients (odds ratio = 0.698, 95% confidence interval = 0.282 to 1.727). In addition, although the rate of minor complications was higher in the RA-THA cohort (21.6% versus 12.5%, P = 0.004), no difference was observed on multivariate analysis (odds ratio = 1.248, 95% confidence interval = 0.852 to 1.829). The average inpatient hospital cost of a RA-THA was $20,046 (SD = 6,165) compared with $18,258 (SD = 6,147) for C-THA (P < 0.001). The average LOS was for RA-THA was 2.69 days (SD = 1.25) compared with 2.82 days for C-THA (SD = 1.18, P < 0.001). DISCUSSION In a statistically matched cohort, the risk of perioperative complication in patients who underwent RA-THA versus C-THA patients were similar. However, RA-THA was costlier despite shorter LOS. LEVEL OF EVIDENCE Level III, retrospective cohort analysis.
Collapse
|
25
|
Perets I, Walsh JP, Mu BH, Mansor Y, Rosinsky PJ, Maldonado DR, Lall AC, Domb BG. Short-term Clinical Outcomes of Robotic-Arm Assisted Total Hip Arthroplasty: A Pair-Matched Controlled Study. Orthopedics 2021; 44:e236-e242. [PMID: 33238012 DOI: 10.3928/01477447-20201119-10] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Advances have made robotic assistance a viable option in total hip arthroplasty (THA). However, the clinical outcomes of this procedure relative to manual THA are limited in the literature. This study compared robotic-arm assisted (RAA) THA and manual THA at minimum 2-year follow-up. Data were collected prospectively on all THAs performed from July 2011 to January 2015. Patients were included if they underwent RAA primary THA for idiopathic osteo-arthritis and had minimum follow-up of 2 years. The following patient-reported outcomes were compared: Harris Hip Score (HHS), Forgotten Joint Score (FJS-12), visual analog scale (VAS) pain score, and satisfaction. Postoperative radio-graphs were analyzed for cup inclination, cup version, leg-length discrepancy, and global offset. Robotic-arm assisted THA patients were matched 1:1 with manual THA patients for age, sex, body mass index, and surgical approach. Each study group included 85 patients. There were no significant differences in the demographic factors between the groups. Both HHS and FJS-12 were significantly higher in the RAA group at minimum 2-year follow-up. The VAS score was lower in the RAA group, but this difference was not statistically significant. A significantly higher proportion of patients were in the Lewinnek and Callanan safe zones for cup orientation. There was no difference between the groups in patient satisfaction. Robotic-arm assisted THA yielded improved short-term patient outcomes compared with manual THA and higher likelihood of cup placement in the safe zones. No differences were found regarding VAS scores, patient satisfaction, complication rates, or subsequent revisions between groups. [Orthopedics. 2021;44(2):e236-e242.].
Collapse
|
26
|
Okamoto M, Kawasaki M, Okura T, Ochiai S, Yokoi H. Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position. Hip Int 2021; 31:492-499. [PMID: 32126836 DOI: 10.1177/1120700020908788] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Accelerometer-based portable navigation systems in supine total hip arthroplasty (THA) have been developed, but there are no reports on the accuracy of cup placement. We aimed to investigate and compare the accuracy of the accelerometer-based portable navigation system versus the acetabular alignment guide placed on the pelvis in THA using the direct anterior approach (DAA). Both devices tracked changes in the pelvic position. METHODS In this single-centre, retrospective study, we reviewed 115 hips in 113 patients who underwent primary THA via the DAA using an accelerometer-based portable navigation system in the supine position (portable navigation group) and 106 hips in 101 patients who underwent THA using an acetabular alignment guide (alignment guide group) as controls. Hips were evaluated postoperatively using computed tomography to measure cup orientation. The accuracy of cup orientation was compared between the 2 groups. RESULTS Absolute values of inclination error were 3.1° ± 2.2° and 2.9° ± 2.3° (p = 0.708) in the portable navigation and alignment guide groups and those of anteversion error were 2.8° ± 2.3° and 3.7° ± 2.7°, respectively (p = 0.005). The number of cups placed within 10° of error was 98.3% and 96.2% in the portable navigation and alignment guide groups, respectively (p = 0.304). The portable navigation group had significantly more hips (72.2%) placed within a 5° margin of error than did the alignment guide group (56.6%) (p = 0.016). CONCLUSION High accuracy in cup placement was achieved using accelerometer-based portable navigation in supine THA. Using a navigation system may contribute to improved long-term outcomes.
Collapse
Affiliation(s)
- Masanori Okamoto
- Department of Orthopaedic Surgery, Aichi Koseiren Konan Kosei Hospital, Konan, Aichi, Japan
| | - Masashi Kawasaki
- Department of Orthopaedic Surgery, Aichi Koseiren Konan Kosei Hospital, Konan, Aichi, Japan
| | - Toshiaki Okura
- Department of Orthopaedic Surgery, Aichi Koseiren Konan Kosei Hospital, Konan, Aichi, Japan
| | - Satoshi Ochiai
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Hiroyuki Yokoi
- Department of Orthopaedic Surgery, Aichi Koseiren Konan Kosei Hospital, Konan, Aichi, Japan
| |
Collapse
|
27
|
Kievit AJ, Dobbe JGG, Mallee WH, Blankevoort L, Streekstra GJ, Schafroth MU. Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens. Hip Int 2021; 31:58-65. [PMID: 31506002 PMCID: PMC7797610 DOI: 10.1177/1120700019874822] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION We tested whether a mechanical device (such as Hipsecure) to pinpoint the anterior pelvic plane (APP) as a guide can improve acetabular cup placement. To assess accuracy we asked: (1) is the APP an effective guide to position acetabular cup placement within acceptable ° of divergence from the optimal 40° inclination and 15° anteversion; (2) could a mechanical device increase the number of acetabular cup placements within Lewinnek's safe zone (i.e. inclination 30° to 50°; anteversion 5° to 25°)? METHODS 16 cadaveric specimens were used to assess the 3D surgical success of using a mechanical device APP to guide acetabular cup placement along the APP. We used the Hipsecure mechanical device to implant acetabular cups at 40° inclination and 15° anteversion. Subequently, all cadaveric specimens with implants were scanned with a CT and 3D models were created of the pelvis and acetabular cups to assess the outcome in terms of Lewinnek's safe zones. RESULTS The mean inclination of the 16 implants was 40.6° (95% CI, 37.7-43.4) and the mean anteversion angle was 13.4° (95% CI, 10.7-16.1). All 16 cup placements were within Lewinnek's safe zone for inclination (between 30° and 50°) and all but 2 were within Lewinnek's safe zone for anteversion (between 5° and 25°). CONCLUSION In cadaveric specimens, the use of a mechanical device and the APP as a guide for acetabular cup placement resulted in good positioning with respect to both of Lewinnek's safe zones.
Collapse
Affiliation(s)
- Arthur J Kievit
- Orthopaedic Research Centre Amsterdam, Department of Orthopaedics of the Amsterdam University Medical Centre, University of Amsterdam, The Netherlands,Arthur J Kievit, Orthopaedic Research Centre Amsterdam, Department of Orthopaedics of the Amsterdam University Medical Centre, University of Amsterdam, Amsterdam 1105 AZ, The Netherlands.
| | - Johannes G G Dobbe
- Department of Biomedical Engineering and Physics of the Amsterdam University Medical Centre, University of Amsterdam, The Netherlands
| | - Wouter H Mallee
- Orthopaedic Research Centre Amsterdam, Department of Orthopaedics of the Amsterdam University Medical Centre, University of Amsterdam, The Netherlands
| | - Leendert Blankevoort
- Orthopaedic Research Centre Amsterdam, Department of Orthopaedics of the Amsterdam University Medical Centre, University of Amsterdam, The Netherlands
| | - Geert J Streekstra
- Department of Biomedical Engineering and Physics of the Amsterdam University Medical Centre, University of Amsterdam, The Netherlands
| | - Matthias U Schafroth
- Orthopaedic Research Centre Amsterdam, Department of Orthopaedics of the Amsterdam University Medical Centre, University of Amsterdam, The Netherlands
| |
Collapse
|
28
|
Sunilkumar PD, Oh KJ, Cho HW, Kim SM. Monolithic Dual Mobility Cup Total Hip Arthroplasty Has High Complication Rates With Surgical Fixation in Elderly With Femur Neck Fracture. J Arthroplasty 2020; 35:3621-3626. [PMID: 32773273 DOI: 10.1016/j.arth.2020.06.091] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 06/22/2020] [Accepted: 06/30/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND This study is prospectively conducted to evaluate surgical complications of monolithic dual mobility cup total hip arthroplasty (THA) in elderly patients with fractured neck of the femur. METHODS Ninety-seven patients (97 hips) with displaced femoral neck fracture who gave informed consent for participation were prospectively enrolled. Their mean age was 76.6 years (range, 60-95 years), and the mean bone mineral density T-score of neck of the femur was -2.8 (range, -1.2 to -5.5). All patients underwent THA with monolithic dual mobility cup, and computed tomography scans were obtained to evaluate radiographic parameters including anteversion, inclination, and loosening of acetabular cups, and periprosthetic acetabular fractures. RESULTS With regard to cup orientation, mean inclination angle was 40.2° (range, 23.5°-63°) and mean anteversion was 32.6° (range, 7°-66.2°). The proportion of surgical outliers was 10.3% (10/97) in inclination and 35.1% (34/97) in anteversion. Early cup loosening within 2 weeks was detected in 2 hips. Periprosthetic acetabular fractures were identified in 6 hips (6/97, 6.2%). Of the 6 fractures, 5 nondisplaced fractures were healed with conservative management, but 1 fracture with displacement eventually led to cup loosening and the patient underwent revision surgery. Reoperation rate of the monolithic dual mobility cup was 4.1% (4/97). CONCLUSION The use of the monolithic dual mobility was associated with improper cup fixation and periprosthetic acetabular fractures in the elderly with poor bone stock, although the dual mobility cup lowered the risk of early dislocation after THA.
Collapse
Affiliation(s)
- P D Sunilkumar
- Sharada Orthopaedics and Trauma Centre, Hubli, Republic of India
| | - Kwang-Jun Oh
- Department of Orthopedic Surgery, Sungmin Hospital, Incheon, Republic of Korea
| | - Hyun-Woo Cho
- Department of Orthopedic Surgery, Korea University College of Medicine, Guro Hospital, Seoul, Republic of Korea
| | - Sang-Min Kim
- Department of Orthopedic Surgery, Korea University College of Medicine, Guro Hospital, Seoul, Republic of Korea
| |
Collapse
|
29
|
Burapachaisri A, Elbuluk A, Abotsi E, Pierrepont J, Jerabek SA, Buckland AJ, Vigdorchik JM. Lewinnek Safe Zone References are Frequently Misquoted. Arthroplast Today 2020; 6:945-953. [PMID: 33299915 PMCID: PMC7701843 DOI: 10.1016/j.artd.2020.09.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/13/2020] [Accepted: 09/27/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Optimal acetabular component orientation in total hip arthroplasty (THA) is a necessity in achieving a stable implant. Although there has been considerable debate in the literature concerning the safe zone, to date, there has not been any review to determine if these references are consistent with the definition applied by Lewinnek et al. in 1978. Therefore, this article aims to examine the available literature in the PubMed database to determine how often a correct reference to the safe zone as defined by Lewinnek was applied to discussions regarding THA. METHODS A search for literature in the PubMed database was performed for articles from 1978 to 2019. Search criteria included terms 'Lewinnek,' 'safe zone,' and 'total hip arthroplasty.' Exclusions included abstract-only articles, non-English articles, articles unrelated to THA, and those lacking full content. RESULTS A review of literature yielded 147 articles for inclusion. Overall, only 11% (17) cited the Lewinnek article correctly. Forty-five percent (66) of articles referenced measurements in the supine position, 18% (26) referenced other positions, and 37% (55) did not specify. Nineteen percent (28) reported measurements of the acetabular cup orthogonal to the anterior pelvic plane, while 73% (108) did not, and 7% (11) did not specify. Twenty-three percent (34) measured from computed tomography scans instead of other methods. CONCLUSIONS In the discussion of the safe zone regarding THA, only 11% of articles listed are consistent with the definition established by Lewinnek. This warrants further investigation into a consistent application of the term and its implications for THA implant stability and dislocation rates.
Collapse
Affiliation(s)
- Aonnicha Burapachaisri
- Division of Spine Surgery, Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA
| | - Ameer Elbuluk
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Edem Abotsi
- Division of Spine Surgery, Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA
| | - Jim Pierrepont
- Chief Innovation Officer, Corin Group, New South Wales, Australia
| | - Seth A. Jerabek
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Aaron J. Buckland
- Division of Spine Surgery, Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA
| | - Jonathan M. Vigdorchik
- Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
30
|
Mihalič R, Zdovc J, Mohar J, Trebše R. Electromagnetic navigation system for acetabular component placement in total hip arthroplasty is more precise and accurate than the freehand technique: a randomized, controlled trial with 84 patients. Acta Orthop 2020; 91:675-681. [PMID: 32608315 PMCID: PMC8023939 DOI: 10.1080/17453674.2020.1783073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The accuracy of conventional navigation systems depends on precise registration of bony landmarks. We investigated the clinical use of electromagnetic navigation (EMN), with a unique device for precise determination of the anterior pelvic plane. Patients and methods - We randomly allocated patients scheduled for total hip arthroplasty into 2 groups of 42 patients each. In the study group, cups were placed at the predetermined target angles (inclination: 42.5°; anteversion: 15°) with the support of EMN. In the control group, cups were placed freehand aiming at the same target angles. Postoperatively the true position of the cup was determined using computed tomography scan of the pelvis. Precision (root mean squared error, RMSE) bias (mean bias error, ME), accuracy, and duration of surgery were compared between the methods. Results - Cup anteversion was more accurate and precise in the navigated group. The ME in the navigated and freehand group was -1.7° (95% CI -2.4 to 1.1) and -4.5° (CI -6.5 to 2.5), respectively. The RMSE in the navigated and freehand group was 2.8° (CI 2.3-3.2) and 8.0° (CI 6.3-9.5), respectively. The inclination was also more precise in the navigated group, with the RMSE in the navigated and freehand group at 4.6° (CI 3.4-5.9) and 6.5° (CI 5.4-7.5), respectively. The accuracy of the inclination and the duration of surgeries were similar between the groups. Interpretation - Cup placement with the help of EMN is more precise than the freehand technique and it does not affect the duration of surgery.
Collapse
Affiliation(s)
- Rene Mihalič
- Valdoltra Orthopaedic Hospital, Ankaran,Correspondence:
| | - Jurij Zdovc
- University of Ljubljana, Faculty of Pharmacy, Ljubljana
| | | | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Ankaran,University of Ljubljana, Faculty of Medicine, Ljubljana, Slovenia
| |
Collapse
|
31
|
Wang R, Zheng X, Xu T, Gong S, Liu S, Han L, Yang S, Xu W. Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty. Front Bioeng Biotechnol 2020; 8:988. [PMID: 32974316 PMCID: PMC7471602 DOI: 10.3389/fbioe.2020.00988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/29/2020] [Indexed: 11/13/2022] Open
Abstract
Objective Precise hip cup positioning is essential for the prevention of component impingement and dislocation in robotic assisted total hip arthroplasty (THA). Currently, the robotic system uses a mechanical alignment guide (MAG) for cup placement, which is one-size-fits-all, and the optimal cup positioning is controversial. Robotic assisted THA has not used any personalized cup positioning guides. The goal of this study was to identify an optimal guide for cup placement in robotic assisted THA to improve prognosis and life quality after THA. Materials and Methods Pelvis and femoral CT data of 47 participants were retrospectively collected for preoperative planning of robotic THA. The universal MAG guide and three personalized guides, including acetabular rim labrum guide (ARLG), transverse acetabular ligament guide (TALG), and ischiatic-pubis line guide (IPLG), were used to pose cups in the acetabulum of each participant. The position of cups was evaluated by inclination and anteversion; the function of hip joints was evaluated by hip ranges of motion, including abduction, adduction, extension, flexion, internal rotation, and external rotation. Results In terms of cup positioning, ARLG provided a bigger cup inclination (p < 0.0001), while IPLG and TALG provided smaller cup inclination (p < 0.001) than MAG; the three personalized guides provided larger cup anteversion (p < 0.0001) than MAG. In terms of HROMs, compared with the use of MAG, the use of three personalized guides significantly decreased abduction (p < 0.0001), extension (p < 0.0001), and external rotation (p < 0.0001), but increased significantly flexion (p < 0.0001) and internal rotation (p < 0.0001); the use of ARLG significantly reduced adduction (p < 0.0001), but the use of IPLG and TALG increased adduction (p < 0.0001). Conclusion Compared with MAG, personalized guides provided greater flexion and internal rotation, which may reduce the risk of posterior dislocation. Among the three personalized guides, IPLG is the most reliable one for the preoperative planning of robotic assisted THA.
Collapse
Affiliation(s)
- Ruoyu Wang
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaojing Zheng
- Department of Pediatrics, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States.,Department of Biostatistics, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States
| | - Tianze Xu
- Department of Pediatrics, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States.,Department of Biostatistics, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States.,College of ACES, University of Illinois at Urbana-Champaign, Urbana, IL, United States
| | - Song Gong
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shaokai Liu
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Lizhi Han
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shuhua Yang
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Weihua Xu
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
32
|
Li L, Zhang Y, Lin YY, Li ZX, Chen L, Chen DS, Fan P. A Specific Anteversion of Cup and Combined Anteversion for Total Hip Arthroplasty Using Lateral Approach. Orthop Surg 2020; 12:1663-1673. [PMID: 32924261 PMCID: PMC7767786 DOI: 10.1111/os.12790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 07/27/2020] [Accepted: 06/30/2020] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE To determine the implant orientation, especially the combined anteversion measurements in total hip arthroplasty (THA) using lateral approach, and to compare with implant orientation using posterior-lateral (P-L) approach. The secondary goal was to identify the factors associated with implant orientation. METHODS Five hundred and one patients (545 hips) who underwent primary THA with the modified Hardinge approach between January 2016 and November 2019 by one senior surgeon in our department in a retrospective study were followed up. A survey to inquire about the history of dislocation of the hip after THA was designed and responses were gathered by telephone, WeChat software, and outpatient follow-up. The mean age of the patients was 61.97 ± 11.72 years, and there were 254 males and 247 females. The average follow-up time was 25.2 ± 13.7 months (range, 3.2-49.7 months). Among the patients who were followed up, 97 patients (104 hips) underwent computed tomography (CT) scans from L4 to the tuberosity of the tibia. The implant orientation, including the anteversion and inclination of the cup, anteversion of the stem, combined anteversion, and pelvic tilt were measured based on CT scans of these patients. The results were compared with the implant orientation reported in previous reports measured by CT. Factors that may be associated with implant orientation were investigated, including the patient's age, sex, body mass index (BMI), and diagnosis; size of the cup; diameter of the femoral head component; and pelvic tilt. Data and statistical analyses were performed using SPSS 20.0. RESULTS No cases of dislocation were found in the 501 patients (545 hips) who underwent primary THA during this period. The mean inclination and anteversion of the cups were 38.83° ± 5.04° (24.5°-53.1°) and 9.26° ± 11.19° (-15°-48°), respectively. The mean anteversion of the stem was 13.83° ± 10.7° (-10.2°-42.3°). The combined anteversion was 23.1° ± 13.4° (-7.4°-54.6°). Compared with the reported combined anteversion and anteversion of the cup, the mean anteversion of the cup and combined anteversion using the lateral approach were much lower than the reported values in the literature using the P-L approach. Pelvic tilt was found to be the only independent factor for cup anteversion. Factors including age, sex, BMI, diagnosis, cup size, and diameter of the femoral head component were not associated with implant orientation. CONCLUSION THA using the lateral approach yields smaller cup anteversion and combined anteversion values than using the P-L approach. Pelvic tilt is the only predictor for cup anteversion.
Collapse
Affiliation(s)
- Li Li
- Zhejiang Provincial Key Laboratory of Anesthesiology, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| | - Yu Zhang
- Zhejiang Provincial Key Laboratory of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| | - Yuan-Yuan Lin
- Zhejiang Provincial Key Laboratory of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| | - Zhen-Xing Li
- Zhejiang Provincial Key Laboratory of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| | - Liang Chen
- Zhejiang Provincial Key Laboratory of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| | - Dao-Sen Chen
- Zhejiang Provincial Key Laboratory of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| | - Pei Fan
- Zhejiang Provincial Key Laboratory of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China.,Department of Orthopaedics, The Second Affiliated Hospital of Wenzhou Medical University, Yuying Children's Hospital, Wenzhou, China
| |
Collapse
|
33
|
Sahin A, Simsek ME, Gursoy S, Akkaya M, Isik C, Bozkurt M. Three-dimensional analysis of acetabular cup orientation and an evaluation of the relationship with pelvic sagittal parameters. J Orthop Surg (Hong Kong) 2020; 27:2309499019861225. [PMID: 31284813 DOI: 10.1177/2309499019861225] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND This study aimed to evaluate the effect of total hip arthroplasty (THA) on sagittal pelvic parameters and to evaluate the effect of sagittal pelvic parameters on acetabular cup orientation. METHODS The study included 86 patients who underwent THA for a diagnosis of unilateral coxarthrosis between 2011 and 2015. Measurements were taken of the preoperative and postoperative acetabular cup inclination (ACI), anteversion, and sagittal pelvic parameters. The effect of THA on sagittal pelvic parameters and the effects of the sagittal pelvic parameters on acetabular cup orientation were investigated. RESULTS The sagittal pelvic tilt values calculated were mean 9.7° ± 6.3° (2°; 23°) preoperatively and 11.0° ± 6.1° (2°; 25°) postoperatively. The increase in postoperative pelvic incidence (PI) values was determined to be statistically significant (p < 0.05). The preoperative PI values had no significant effect on ACI, but in cases with high preoperative PI values, a tendency to high anteversion values was determined. The mean inclination values were found to be 40.2° ± 11.0° in the low PI group, 41.7° ± 7.4° in the normal PI group, and 44.1° ± 8.3° in the high PI group. As no increase in inclination values was observed with an increase in PI values, no statistical correlation was determined (p = 0.343). Average of anteversion values in the low PI group was 9.2° ± 13.7°, in the normal PI group 19.3° ± 10.5°, and in the high PI group 21.1° ± 12.5°. The difference between the groups was statistically significant (p = 0.001). CONCLUSION Evaluating the results of this study, it can be concluded that varying PI values do affect the acetabular cup anterversion in THA. So, preoperative assessment of PI values is important in preventing postoperative acetabular cup malposition.
Collapse
Affiliation(s)
- Ali Sahin
- 1 Department of Orthopedics and Traumatology, Erzurum Training and Research Hospital, Erzurum, Turkey
| | - Mehmet Emin Simsek
- 2 Department of Orthopedics and Traumatology, Yenimahalle Training and Research Hospital, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Safa Gursoy
- 2 Department of Orthopedics and Traumatology, Yenimahalle Training and Research Hospital, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Mustafa Akkaya
- 2 Department of Orthopedics and Traumatology, Yenimahalle Training and Research Hospital, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Cetin Isik
- 3 Department of Orthopedics and Traumatology, Ataturk Training and Research Hospital, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Murat Bozkurt
- 4 Department of Orthopedics and Traumatology, Ankara Yildirim Beyazit University, Ankara, Turkey
| |
Collapse
|
34
|
Feng JE, Anoushiravani AA, Eftekhary N, Wiznia D, Schwarzkopf R, Vigdorchik JM. Techniques for Optimizing Acetabular Component Positioning in Total Hip Arthroplasty: Defining a Patient-Specific Functional Safe Zone. JBJS Rev 2020; 7:e5. [PMID: 30817692 DOI: 10.2106/jbjs.rvw.18.00049] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- James E Feng
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, NYU Langone Health, New York, NY
| | - Afshin A Anoushiravani
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, NYU Langone Health, New York, NY.,Department of Orthopaedics, Albany Medical Center, Albany, New York
| | - Nima Eftekhary
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, NYU Langone Health, New York, NY
| | - Daniel Wiznia
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, NYU Langone Health, New York, NY.,Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, Connecticut
| | - Ran Schwarzkopf
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, NYU Langone Health, New York, NY
| | - Jonathan M Vigdorchik
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, NYU Langone Health, New York, NY
| |
Collapse
|
35
|
Woon CYL, Muir JM, Su EP. Using Imageless Optical Navigation to Identify the New Hip Center in Crowe IV Dysplasia. Orthopedics 2020; 43:e119-e122. [PMID: 31881087 DOI: 10.3928/01477447-20191223-06] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 09/09/2019] [Indexed: 02/03/2023]
Abstract
In total hip arthroplasty for patients with acetabular dysplasia, cup placement in the native acetabulum is preferred to placement in the pseudoacetabulum. Identifying the true acetabulum may prove challenging. In a patient with Crowe IV dysplasia, 3-dimensional mini-optical navigation was used to match the new hip center to the preoperative radiographic plan, which was identified to be 34 mm inferior to the pseudoacetabulum. This allowed titration of femoral shortening to 20 mm, to arrive at final limb lengthening of 14 mm. Although the use of other enabling technologies in hip dysplasia has been reported, to the authors' knowledge, this is the first reported case demonstrating the use of imageless optical navigation in this setting. It is a navigational tool with a small spatial footprint, does not mandate preoperative axial studies, and does not require multipoint bone surface registration. Imageless navigation may be a useful option for cup positioning and subsequent titration of femoral shortening in the reconstruction of Crowe IV dysplastic hips with degenerative joint disease. [Orthopedics. 2020; 43(2):e119-e122.].
Collapse
|
36
|
Perets I, Mu BH, Mont MA, Rivkin G, Kandel L, Domb BG. Current topics in robotic-assisted total hip arthroplasty: a review. Hip Int 2020; 30:118-124. [PMID: 31868012 DOI: 10.1177/1120700019893636] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Total hip arthroplasty (THA) is among the most successful procedures of modern medicine, yet failures and complications continue to occur, leaving room for improvement. Robotics is a cutting-edge technology that tries to improve joint arthroplasty surgery. There is some evidence that shows that robotic-assisted THA improves implant positioning, but less is known about its effect on clinical outcomes or the rate of complications. This article reviews the literature on robotic-assisted THA to elucidate the history, advantages, disadvantages, and current clinical understanding of this procedure.
Collapse
Affiliation(s)
- Itay Perets
- American Hip Institute, Des Plaines, IL, USA.,Hadassa Hebrew University Hospital, Jerusalem, Israel
| | - Brian H Mu
- American Hip Institute, Des Plaines, IL, USA.,Rosalind Franklin University of Medicine and Science, North Chicago, IL, USA
| | - Michael A Mont
- Lenox Hill Hospital, Northwell Health, New York, NY, USA.,Cleveland Clinic, Cleveland, OH, USA
| | - Gurion Rivkin
- Hadassa Hebrew University Hospital, Jerusalem, Israel
| | - Leonid Kandel
- Hadassa Hebrew University Hospital, Jerusalem, Israel
| | | |
Collapse
|
37
|
Li Q, Chen X, Lin B, Ma Y, Liao JX, Zheng Q. Three-dimensional technology assisted trabecular metal cup and augments positioning in revision total hip arthroplasty with complex acetabular defects. J Orthop Surg Res 2019; 14:431. [PMID: 31829273 PMCID: PMC6907278 DOI: 10.1186/s13018-019-1478-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 11/14/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Revision total hip arthroplasty (THA) with large acetabular defect remains a challenge. Though trabecular metal (TM) cup and augments have been introduced in defect reconstruction with good result, the accurate positioning of implant is important to avoid complications. Therefore, we aimed to evaluate the usefulness of three-dimensional (3D) simulation and 3D model in assisting implant positioning during complex revision THA. METHODS Sixteen patients (18 hips) who underwent revision THA with a Paprosky type III acetabular defect were analyzed retrospectively. Placement of acetabular cup and TM augments was simulated with 3D simulation software and 3D model preoperatively. Cup anteversion, abduction angle, and hip center were measured in each case preoperatively and postoperatively. Primary outcome was the percentage of outliers according to Lewinnek safe zone and Harris hip score (HHS). Secondary outcome was the correlation between the 3D planned and the postoperative value. RESULTS The percentage of outliers was significantly corrected from 77.78% (14/18) preoperatively to 38.88% (7/18) postoperatively (p = 0.04). There was a significant correlation between mean planned cup anteversion and postoperative value (13.39 vs 11.99, r = 0.894; p < 0.001). There was a significant correlation between mean planned abduction and postoperative value (42.67 vs 44.91, r = 0.921, p < 0.001). The number of planned and used augments was the same in all the cases. In 15 cases (83.33%), the size of planned and used TM augments was the same. The HHS was significantly improved at final follow-up (80.94 vs 27.50, p < 0.001). No cases presented dislocation or radiological signs of loosening. CONCLUSION Preoperative 3D simulation and model were considered the useful method to assist implant positioning in revision THA with complex acetabular defect, with moderate to high accuracy and satisfied clinical outcome.
Collapse
Affiliation(s)
- Qingtian Li
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, School of Medicine, South China University of Technology, No. 106, Zhongshan Second Road, Yuexiu District, Guangzhou, 510000, China
| | - Xuepan Chen
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, School of Medicine, South China University of Technology, No. 106, Zhongshan Second Road, Yuexiu District, Guangzhou, 510000, China
- Shantou University Medical College, Shantou, China
| | - Bofu Lin
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, School of Medicine, South China University of Technology, No. 106, Zhongshan Second Road, Yuexiu District, Guangzhou, 510000, China
| | - Yuanchen Ma
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, School of Medicine, South China University of Technology, No. 106, Zhongshan Second Road, Yuexiu District, Guangzhou, 510000, China
| | - Jun Xing Liao
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, School of Medicine, South China University of Technology, No. 106, Zhongshan Second Road, Yuexiu District, Guangzhou, 510000, China
| | - Qiujian Zheng
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, School of Medicine, South China University of Technology, No. 106, Zhongshan Second Road, Yuexiu District, Guangzhou, 510000, China.
| |
Collapse
|
38
|
Kazarian GS, Lawrie CM, Barrack TN, Donaldson MJ, Miller GM, Haddad FS, Barrack RL. The Impact of Surgeon Volume and Training Status on Implant Alignment in Total Knee Arthroplasty. J Bone Joint Surg Am 2019; 101:1713-1723. [PMID: 31577676 DOI: 10.2106/jbjs.18.01205] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Implant malalignment may predispose patients to prosthetic failure following total knee arthroplasty (TKA). A more thorough understanding of the surgeon-specific factors that contribute to implant malalignment following TKA may uncover actionable strategies for improving implant survival. The purpose of this study was to determine the impact of surgeon volume and training status on malalignment. METHODS In this retrospective multicenter study, we performed a radiographic analysis of 1,570 primary TKAs performed at 4 private academic and state-funded centers in the U.S. and U.K. Surgeons were categorized as high-volume (≥50 TKAs/year) or low-volume (<50 TKAs/year), and as a trainee (fellow/resident under the supervision of an attending surgeon) or a non-trainee (attending surgeon). On the basis of these designations, 3 groups were defined: high-volume non-trainee, low-volume non-trainee, and trainee. The postoperative medial distal femoral angle (DFA), medial proximal tibial angle (PTA), and posterior tibial slope angle (PSA) were radiographically measured. Outlier measurements were defined as follows: DFA, outside of 5° ± 3° of valgus; PTA, >±3° deviation from the neutral axis; and PSA, <0° or >7° of flexion for cruciate-retaining or <0° or >5° of flexion for posterior-stabilized TKAs. "Far outliers" were defined as measurements falling >± 2° outside of these ranges. The proportions of outliers were compared between the groups using univariate and multivariate analyses. RESULTS When comparing the high and low-volume non-trainee groups using univariate analysis, the proportions of knees with outlier measurements for the PTA (5.3% versus 17.4%) and PSA (17.4% versus 28.3%) and the proportion of total outliers (11.8% versus 20.7%) were significantly lower in the high-volume group (all p < 0.001). The proportions of DFA (1.9% versus 6.5%), PTA (1.8% versus 5.7%), PSA (5.5% versus 12.6%), and total far outliers (3.1% versus 8.3%) were also significantly lower in the high-volume non-trainee group (all p < 0.001). Compared with the trainee group, the high-volume non-trainee group had significantly lower proportions of DFA (12.6% versus 21.6%), PTA (5.3% versus 12.0%), PSA (17.4% versus 33.3%), and total outliers (11.8% versus 22.3%) (all p < 0.001) as well as DFA (1.9% versus 3.9%; p = 0.027), PSA (5.5% versus 12.6%; p < 0.001), and total far outliers (3.1% versus 6.4%; p = 0.004). No significant differences were identified when comparing the low-volume non-trainee group and the trainee group, with the exception of PTA outliers (17.4% versus 12.0%; p = 0.041) and PTA far outliers (5.7% versus 2.6%; p = 0.033). Findings from multivariate analysis accounting for the effects of patient age, body mass index, and individual surgeon demonstrated similar results. CONCLUSIONS Low surgical volume and trainee status were risk factors for outlier and far-outlier malalignment in primary TKA, even when accounting for differences in individual surgeon and patient characteristics. Trainee surgeons performed similarly, and certainly not inferiorly, to low-volume non-trainee surgeons. Even among high-volume non-trainees, the best-performing cohort in our study, the proportion of TKA alignment outliers was still high. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Gregory S Kazarian
- Department of Orthopaedic Surgery, Washington University in St. Louis School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| | - Charles M Lawrie
- Department of Orthopaedic Surgery, Washington University in St. Louis School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| | - Toby N Barrack
- Department of Orthopaedic Surgery, Washington University in St. Louis School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| | - Matthew J Donaldson
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, London, United Kingdom.,Department of Orthopaedic Surgery, The Princess Grace Hospital, London, United Kingdom
| | - Gary M Miller
- Department of Orthopaedic Surgery, John Cochran Veterans Hospital-VA St. Louis Health Care System, St. Louis, Missouri
| | - Fares S Haddad
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, London, United Kingdom.,Department of Orthopaedic Surgery, The Princess Grace Hospital, London, United Kingdom
| | - Robert L Barrack
- Department of Orthopaedic Surgery, Washington University in St. Louis School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| |
Collapse
|
39
|
Yoshitani J, Nakamura T, Maruhashi Y, Hashimoto N, Sasagawa T, Ueshima K, Funaki K. Is the alignment guide technique in total hip arthroplasty sufficient for accurate cup positioning with a modified Watson Jones approach? J Orthop Surg (Hong Kong) 2019; 26:2309499018806645. [PMID: 30352543 DOI: 10.1177/2309499018806645] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
PURPOSE: Cup setting with only an alignment guide has been reported to be inaccurate in the lateral decubitus position in total hip arthroplasty (THA). We assessed the accuracy of cup positioning using only the alignment guide technique via a modified Watson Jones approach in the lateral decubitus position. METHODS: Two hundred hips of 189 patients underwent THA from October 2014 to September 2016 via a modified Watson Jones approach. In the final sample, 181 hips of 171 patients (35 males, 136 females) were included in this investigation. The alignment of the cup was evaluated by an anteroposterior radiograph of the pelvis 1 week after surgery. Measurements were divided into safe zone determined by Callanan and Lewinnek. RESULTS: There were 168 (92.8%) acetabular cups that were placed within the safe zone for both inclination and anteversion based on the safe zones defined by Lewinnek, and 134 (74%) acetabular cups that were placed within the safe zone defined by Callanan. Multiple logistic analysis showed that the laterality and the addition of the confirmation method were indicators for malpositioning of combined inclination and anteversion. CONCLUSION: Our data suggested that even if special tools were not used in the lateral decubitus position, using only the alignment guide enabled cup positioning to be achieved with 92.8% accuracy in the Lewinnek safe zone and 74% accuracy in the Callanan safe zone. Multiple logistic analysis showed that the laterality and the addition of a confirmation alignment guide influenced the accuracy of cup positioning.
Collapse
Affiliation(s)
- Junya Yoshitani
- 1 Department of Orthopaedic Surgery, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan
| | - Takuya Nakamura
- 2 Department of Orthopaedic Surgery, Toyama Prefectural Central Hospital, Toyama, Japan
| | - Yoshinobu Maruhashi
- 2 Department of Orthopaedic Surgery, Toyama Prefectural Central Hospital, Toyama, Japan
| | - Noriyuki Hashimoto
- 2 Department of Orthopaedic Surgery, Toyama Prefectural Central Hospital, Toyama, Japan
| | - Takeshi Sasagawa
- 2 Department of Orthopaedic Surgery, Toyama Prefectural Central Hospital, Toyama, Japan
| | - Kenichi Ueshima
- 2 Department of Orthopaedic Surgery, Toyama Prefectural Central Hospital, Toyama, Japan
| | - Kiyonobu Funaki
- 2 Department of Orthopaedic Surgery, Toyama Prefectural Central Hospital, Toyama, Japan
| |
Collapse
|
40
|
Al-Amiry B, Pantelakis G, Mahmood S, Kadum B, Brismar TB, Sayed-Noor AS. Does body mass index affect restoration of femoral offset, leg length and cup positioning after total hip arthroplasty? A prospective cohort study. BMC Musculoskelet Disord 2019; 20:422. [PMID: 31510993 PMCID: PMC6739956 DOI: 10.1186/s12891-019-2790-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 08/27/2019] [Indexed: 01/12/2023] Open
Abstract
Background In obese patients, total hip arthroplasty (THA) can be technically demanding with increased perioperative risks. The aim of this prospective cohort study is to evaluate the effect of body mass index (BMI) on radiological restoration of femoral offset (FO) and leg length as well as acetabular cup positioning. Methods In this prospective study, patients with unilateral primary osteoarthritis (OA) treated with THA between September 2010 and December 2013 were considered for inclusion. The perioperative plain radiographs were standardised and used to measure the preoperative degree of hip osteoarthritis, postoperative FO, leg length discrepancy (LLD), acetabular component inclination and anteversion. Results We included 213 patients (74.5% of those considered for inclusion) with a mean BMI of 27.7 (SD 4.5) in the final analysis. The postoperative FO was improper in 55% and the LLD in 15%, while the cup inclination and anteversion were improper in 13 and 23% of patients respectively. A multivariable logistic regression model identified BMI as the only factor that affected LLD. Increased BMI increased the risk of LLD (OR 1.14, 95% CI 1.04 to 1.25). No other factors included in the model affected any of the primary or secondary outcomes. Conclusion Increased BMI showed a negative effect on restoration of post-THA leg length but not on restoration of FO or positioning of the acetabular cup. Age, gender, OA duration or radiological severity and surgeon’s experience showed no relation to post-THA restoration of FO, leg length or cup positioning.
Collapse
Affiliation(s)
- Bariq Al-Amiry
- Department of Surgical and Perioperative Sciences, Umeå University, 901 85, Umeå, Sweden
| | - Georgios Pantelakis
- Department of Surgical and Perioperative Sciences, Umeå University, 901 85, Umeå, Sweden
| | - Sarwar Mahmood
- Department of Surgical and Perioperative Sciences, Umeå University, 901 85, Umeå, Sweden
| | - Bakir Kadum
- Institutionen för klinisk och experimentell medicin, Linköping University, 58183, Linköping, Sweden
| | - Torkel B Brismar
- Department of Clinical Science, Intervention and Technology, Karolinska Institute, 171 77, Stockholm, Sweden
| | - Arkan S Sayed-Noor
- Department of Surgical and Perioperative Sciences, Umeå University, 901 85, Umeå, Sweden.
| |
Collapse
|
41
|
Cheung A, Yan CH, Fu H, Cheung MH, Chan PK, Chiu KY. Ten- to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear? J Arthroplasty 2019; 34:2016-2021. [PMID: 31176564 DOI: 10.1016/j.arth.2019.04.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 04/16/2019] [Accepted: 04/22/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Increase in acetabular cup abduction in total hip arthroplasty (THA) using conventional polyethylene is associated with greater linear wear. Whether this relationship holds true for highly crosslinked liners, particularly with long-term follow-up, is still controversial. The effect of liner thickness on wear of highly cross-linked liners also remains to be clarified.This study sought to determine (1) the long-term clinical and radiological performance of highly cross-linked polyethylene in THA and (2) the effect of acetabular component positioning, polyethylene thickness, and patient demographics on wear. METHODS Ninety-three THAs using a 28-mm hip ball, single brand of highly cross-linked polyethylene liner, and cementless cup were performed in 87 patients. Clinical outcomes were evaluated using the Harris Hip Score and need for revision surgery. Linear and volumetric wear, presence of osteolysis, and cup abduction angle were assessed. RESULTS The mean age at operation was 51.4 years. The mean duration of follow-up was 12.7 years (10-16 years). Patients aged >50 years had higher rates of linear wear than those aged <50 years (P = .015). Positive correlation was found between cup abduction angle (P = .014) and cup version (P = .035) with a linear wear rate. Thinner liners (≤7 mm) had similar rates of linear and volumetric wear as thicker liners (≥8 mm) (P = .447). CONCLUSION This is the only study to demonstrate a positive significant relationship between cup abduction angle and version with linear wear rate in THA with at least 10 years of follow-up. Liner thickness was not found to affect wear rates.
Collapse
Affiliation(s)
- Amy Cheung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, Hong Kong SAR, China
| | - Chun Hoi Yan
- Department of Orthopaedics and Traumatology, University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Henry Fu
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, Hong Kong SAR, China
| | - Man Hong Cheung
- Department of Orthopaedics and Traumatology, University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Ping Keung Chan
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, Hong Kong SAR, China
| | - Kwong Yuen Chiu
- Department of Orthopaedics and Traumatology, University of Hong Kong, Hong Kong, Hong Kong SAR, China
| |
Collapse
|
42
|
Cao L, Wang Y, Zou S, Cheng H. A novel positioner for accurately sitting the acetabular component: a retrospective comparative study. J Orthop Surg Res 2019; 14:279. [PMID: 31462276 PMCID: PMC6714239 DOI: 10.1186/s13018-019-1331-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 08/19/2019] [Indexed: 02/02/2023] Open
Abstract
Introduction In this study, we described a positioner which allows a combination of preoperative plan and intraoperative insertion of the cup to improve the reconstruction of the rotation center of the hip. Materials and methods A retrospective study was conducted on 32 consecutive patients (group A) using this positioner and 40 consecutive patients (group B) using conventional method; radiological parameters and clinical measurements before operation and at last follow-up were collected and evaluated. Results Group A had a reconstructed center of rotation (COR) that was 0.19 mm closer to the anatomic COR in height (P < 0.005), compared with group B with 3.45 mm vertical dislocation. There were no statistically significant differences in the horizontal displacement between the two groups. The accuracy of cup inclination was 42.14 ± 3.57 in the group A and 38.73 ± 7.65 in the group B (P = 0.015). The accuracy of cup anteversion was 14.82 ± 1.44 in the group A and 13.08 ± 5.95 in the group B (P = 0.082). All cups in the group A were radiologically stable, while one cup in the group B was radiologically unstable and was successfully treated with second-stage revision. Both of the groups obtained a higher mean postoperative Harris Hip Score. Conclusions Utilizing this positioner helps to restore the COR position more precisely and provides satisfactory radiological and clinical outcomes in the short term, and more studies are required before its widespread adoption for complicated cases.
Collapse
Affiliation(s)
- Liangliang Cao
- Department of Joint Surgery, Zhengzhou Orthopaedic Hospital, 58 Longhai Middle Road, Zhengzhou City, Henan Province, China
| | - Yuehui Wang
- Department of Joint Surgery, Zhengzhou Orthopaedic Hospital, 58 Longhai Middle Road, Zhengzhou City, Henan Province, China.
| | - Shiping Zou
- Department of Joint Surgery, Zhengzhou Orthopaedic Hospital, 58 Longhai Middle Road, Zhengzhou City, Henan Province, China
| | - Hui Cheng
- Department of Joint Surgery, Zhengzhou Orthopaedic Hospital, 58 Longhai Middle Road, Zhengzhou City, Henan Province, China
| |
Collapse
|
43
|
Guo HZ, Yang CX, Tang ZP, Wang CX. The effects of total hip arthroplasty in treating hip bony fusion in young and middle-aged patients with ankylosing spondylitis. J Orthop Surg Res 2019; 14:253. [PMID: 31395063 PMCID: PMC6686551 DOI: 10.1186/s13018-019-1288-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Accepted: 07/23/2019] [Indexed: 02/28/2023] Open
Abstract
Background This study aims to investigate the curative effects of total hip arthroplasty (THA) in treating hip bony fusion for young and middle-aged patients with ankylosing spondylitis (AS). Methods The clinical data of 26 young and middle-aged patients with AS (31 coxae), who were treated with THA and followed-up for more than 3 years in the period between February 1998 and May 2013, were retrospectively analyzed. Among these patients, 22 patients were male (25 coxae) and 4 patients were female (6 coxae). Patients’ age ranged within 19–50 years old, with an average of 31.5 years old. The intervals from arthroplasty to the occurrence of hip joint lesions caused by AS ranged within 2–26 years, with an average of 11.2 years. The average Harris score before the surgery was 19.0 ± 11.5 points. Results Femoral proximal cleavage fracture occurred in one coxa during the surgery and was fixed by the steel wire cerclage. Sciatic nerve traction injury occurred in one coxa after the surgery, which recovered after 6 months. Posterior hip dislocation occurred in one coxa and was immediately treated with manual reduction. All patients were followed-up, and follow-up duration ranged within 36–123 months, with an average of 46.5 months. In the last follow-up, the average Harris score was 87.1 ± 13.1 points, total passive range of motion was 215.0 ± 22.0°, and passive range of flexion was 90.8 ± 9.3°. All these indexes significantly increased compared with pretreatment (P < 0.01). A periacetabular radiolucent line occurred in one coxa with a width of < 2 mm, and no femoral radiolucent line was found during follow-ups in any patient. Heterotopic ossification occurred in four coxae. Conclusion THA treatment for hip bony fusion caused by AS can achieve satisfactory hip function recovery and excellent prosthesis survival rate.
Collapse
Affiliation(s)
- Hong-Zhang Guo
- Department of Orthopaedics, Gansu Provincial Hospital of TCM, Lanzhou, 730050, China
| | - Chen-Xu Yang
- Department of Orthopaedics, Gansu Provincial Hospital of TCM, Lanzhou, 730050, China
| | - Zhao-Peng Tang
- Department of Orthopaedics, Gansu Provincial Hospital of TCM, Lanzhou, 730050, China.
| | - Cheng-Xiang Wang
- Department of Orthopaedics, Gansu Provincial Hospital of TCM, Lanzhou, 730050, China
| |
Collapse
|
44
|
Wasterlain AS, Buza JA, Thakkar SC, Schwarzkopf R, Vigdorchik J. Navigation and Robotics in Total Hip Arthroplasty. JBJS Rev 2019; 5:01874474-201703000-00002. [PMID: 28359074 DOI: 10.2106/jbjs.rvw.16.00046] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Amy S Wasterlain
- Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY
| | | | | | | | | |
Collapse
|
45
|
Kida D, Hashimoto H, Ito N, Kito Y, Mori K, Takahashi N, Tomita Y. An Open-Label, Single-Arm Study of a Patient-Specific Femoral Guide for Total Hip Arthroplasty via the Anterolateral Supine Approach, Linked with Three-Dimensional Surgical Support Software: Study Protocol. Kurume Med J 2019; 65:71-75. [PMID: 30197407 DOI: 10.2739/kurumemedj.ms652002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In total hip arthroplasty (THA), it is generally accepted that the bones of the acetabular cup and femur of hip joint must be accurately cut and components (artificial joint parts) be implanted in exact positions at exact angles to achieve improvement of daily living (ADL) and quality of life (QOL). However, with the conventional surgical method, it is difficult to grasp and measure the acetabular cup and femoral stem precisely during surgery, making some kind of reliable guide necessary. Although it was reported that an accurate angle was achieved in acetabular cup implantation by support instruments for surgical planning, an effective support instrument is now being developed for stem implantation on the out-of-reach femur side. This is the first clinical study to assess the efficacy and safety of anterolateral approach THA using an extracorporeal patient-specific femoral guide (PSG) for stem implantation with three-dimensional (3D) surgical support software in patients with hip joint disease.
Collapse
Affiliation(s)
- Daihei Kida
- Department of Orthopedic Surgery and Rheumatology, National Hospital Organization Nagoya Medical Center
| | - Hiroya Hashimoto
- Clinical Research Center, National Hospital Organization Nagoya Medical Center
| | - Noriko Ito
- Clinical Research Center, National Hospital Organization Nagoya Medical Center
| | | | - Kouichi Mori
- Department of Orthopedic Surgery and Rheumatology, National Hospital Organization Nagoya Medical Center
| | - Nobunori Takahashi
- Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine
| | - Yasushi Tomita
- Department of Cardiology, National Hospital Organization Nagoya Medical Center
| |
Collapse
|
46
|
Jacobs CA, Kusema ET, Keeney BJ, Moschetti WE. Does the thigh circumference affect the positioning of the acetabular component when using the direct anterior approach in total hip arthroplasty? Bone Joint J 2019; 101-B:529-535. [PMID: 31038997 DOI: 10.1302/0301-620x.101b5.bjj-2018-0847.r2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The hypothesis of this study was that thigh circumference, distinct from body mass index (BMI), may be associated with the positioning of components when undertaking total hip arthroplasty (THA) using the direct anterior approach (DAA), and that an increased circumference might increase the technical difficulty. PATIENTS AND METHODS We performed a retrospective review of prospectively collected data involving 155 consecutive THAs among 148 patients undertaken using the DAA at an academic medical centre by a single fellowship-trained surgeon. Preoperatively, thigh circumference was measured at 10 cm, 20 cm, and 30 cm distal to the anterior superior iliac spine, in quartiles. Two blinded reviewers assessed the inclination and anteversion of the acetabular component, radiological leg-length discrepancy, and femoral offset. The radiological outcomes were considered as continuous and binary outcome variables based on Lewinnek's 'safe zone'. RESULTS Similar trends were seen in all three thigh circumference groups. In multivariable analyses, patients in the largest 20 cm thigh circumference quartile (59 cm to 78 cm) had inclination angles that were a mean of 5.96° larger (95% confidence interval (CI) 2.99° to 8.93°; p < 0.001) and anteversion angles that were a mean of 2.92° larger (95% CI 0.47° to 5.37°; p = 0.020) than the smallest quartile. No significant differences were noted in leg-length discrepancy or offset. CONCLUSION There was an associated increase in inclination and anteversion as thigh circumference increased, with no change in the risk of malpositioning the components. THA can be performed using the DAA in patients with large thigh circumference without the risk of malpositioning the acetabular component. Cite this article: Bone Joint J 2019;101-B:529-535.
Collapse
Affiliation(s)
- C A Jacobs
- Department of Orthopaedics, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.,New York University Langone Orthopedic Hospital/Insall Scott Kelly Institute, New York, New York, USA
| | - E T Kusema
- Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.,Harvard T. H. Chan School of Public Health, Boston, Massachusetts, USA
| | - B J Keeney
- Department of Orthopaedics, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.,Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.,Berkley Medical Management Solutions, Overland Park, Kansas, USA
| | - W E Moschetti
- Department of Orthopaedics, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.,Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA
| |
Collapse
|
47
|
Kubota Y, Kaku N, Tabata T, Tagomori H, Tsumura H. Efficacy of Computed Tomography-Based Navigation for Cup Placement in Revision Total Hip Arthroplasty. Clin Orthop Surg 2019; 11:43-51. [PMID: 30838107 PMCID: PMC6389529 DOI: 10.4055/cios.2019.11.1.43] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 11/12/2018] [Indexed: 02/05/2023] Open
Abstract
Background Navigation systems are an effective tool to improve the installation accuracy of the cup in primary total hip arthroplasty. This study aimed to evaluate the efficacy of a computed tomography-based navigation system in achieving optimal installation accuracy of implants in revision total hip arthroplasty and to clarify the usefulness of the navigation system. Methods We conducted a retrospective study of 23 hips in 23 patients who underwent revision total hip arthroplasty using a computed tomography-based navigation system; the control group comprised 33 hips in 33 patients who underwent revision total hip arthroplasty without a navigation system. Results The average cup position with the navigation system was 40.0° ± 3.7° in radiographic abduction angle, 18.8° ± 4.8° in radiographic anteversion, and 41.2° ± 8.9° in combined anteversion; without the navigation system, the average cup position was 38.7° ± 6.1°, 19.0° ± 9.1°, and 33.6° ± 20.5°, respectively. The achievement rate of cup positioning within the Lewinnek safe zone was not significantly different between the navigation group (82.6%) and control group (63.6%). In contrast, the achievement rate of cup positioning within the Widmer combined anteversion guidelines was significantly greater in the navigation group (78.3%) than in the control group (48.0%, p = 0.029). Furthermore, outlier cases in the navigation group had a smaller variance of deviation from the optimal cup position than those in the control group did. Conclusions The results show that the use of navigation for revision total hip arthroplasty improved cup positioning and reduced the range of outliers. Improvement of cup placement accuracy influenced the installation of the stem and also improved the achievement rate of combined anteversion. Thus, a computed tomography-based navigation system is very useful for surgeons when placing the cup within the target angle in revision total hip arthroplasty.
Collapse
Affiliation(s)
- Yuta Kubota
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan
| | - Nobuhiro Kaku
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan
| | - Tomonori Tabata
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan
| | - Hiroaki Tagomori
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan
| | - Hiroshi Tsumura
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan
| |
Collapse
|
48
|
Rutherford M, O'Connor JD, Hill JC, Beverland DE, Lennon AB, Dunne NJ. Patient positioning and cup orientation during total hip arthroplasty: assessment of current UK practice. Hip Int 2019; 29:89-95. [PMID: 29783888 DOI: 10.1177/1120700018760818] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: Acetabular cup orientation during total hip arthroplasty (THA) remains a challenge. This is influenced by patient positioning during surgery and the method used to orientate the acetabular cup. The aim of this study was to assess current UK practice for patient positioning and cup orientation, particularly with respect to patient supports and techniques used to achieve target version and inclination. METHODS: A literature review and pilot study were initially conducted to develop the questionnaire, which was completed by British Hip Society members ( n = 183). As the majority of THA surgical procedures within the UK are performed with the patient in lateral decubitus, orthopaedic surgeons who operated with the patient in the supine position were excluded ( n = 18); a further 6% were incomplete and also excluded ( n = 11). RESULTS: Of those who operated in lateral decubitus, 76.6% ( n = 118/154) used the posterior approach. Only 31% ( n = 47/154) considered their supports to be completely rigid. More than 35% ( n = 55/154) were unhappy with the supports that they presently use. The most common methods for controlling operative inclination and version were a mechanical alignment guide (MAG; n = 78/154; 50.6%) and the transverse acetabular ligament (TAL; n = 82/154; 53.2%); 31.2% (48/154) used a freehand technique to control operative inclination. CONCLUSION: Limited studies have been conducted whereby patient supports have been analysed and key design principles outlined. With 35.7% of the orthopaedic surgeons surveyed having issues with their current supports, a greater awareness of essential characteristics for patient supports is required.
Collapse
Affiliation(s)
- Megan Rutherford
- 1 School of Mechanical and Aerospace Engineering, Queen's University of Belfast, Belfast, UK
| | - John D O'Connor
- 1 School of Mechanical and Aerospace Engineering, Queen's University of Belfast, Belfast, UK
| | - Janet C Hill
- 2 Primary Joint Unit, Musgrave Park Hospital, Belfast, UK
| | | | - Alex B Lennon
- 1 School of Mechanical and Aerospace Engineering, Queen's University of Belfast, Belfast, UK
| | - Nicholas J Dunne
- 3 Centre for Medical Engineering Research, School of Mechanical and Manufacturing Engineering, Dublin City University, Ireland.,7 School of Mechanical and Manufacturing Engineering, Dublin City University,Ireland
| |
Collapse
|
49
|
Hettich G, Schierjott RA, Ramm H, Graichen H, Jansson V, Rudert M, Traina F, Grupp TM. Method for quantitative assessment of acetabular bone defects. J Orthop Res 2019; 37:181-189. [PMID: 30345568 PMCID: PMC6588082 DOI: 10.1002/jor.24165] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Accepted: 10/08/2018] [Indexed: 02/04/2023]
Abstract
The objective of the study was to suggest a novel quantitative assessment of acetabular bone defects based on a statistical shape model, validate the method, and present preliminary results. Two exemplary CT-data sets with acetabular bone defects were segmented to obtain a solid model of each defect pelvis. The pathological areas around the acetabulum were excluded and a statistical shape model was fitted to the remaining healthy bone structures. The excluded areas were extrapolated such that a solid model of the native pelvis per specimen resulted (i.e., each pelvis without defect). The validity of the reconstruction was tested by a leave-one-out study. Validation results showed median reconstruction errors of 3.0 mm for center of rotation, 1.7 mm for acetabulum diameter, 2.1° for inclination, 2.5° for anteversion, and 3.3 mm3 for bone volume around the acetabulum. By applying Boolean operations on the solid models of defect and native pelvis, bone loss and bone formation in four different sectors were assessed. For both analyzed specimens, bone loss and bone formation per sector were calculated and were consistent with the visual impression. In specimen_1 bone loss was predominant in the medial wall (10.8 ml; 79%), in specimen_2 in the posterior column (15.6 ml; 46%). This study showed the feasibility of a quantitative assessment of acetabular bone defects using a statistical shape model-based reconstruction method. Validation results showed acceptable reconstruction accuracy, also when less healthy bone remains. The method could potentially be used for implant development, pre-clinical testing, pre-operative planning, and intra-operative navigation. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 9999:1-9, 2018.
Collapse
Affiliation(s)
- Georg Hettich
- Aesculap AG, Research & DevelopmentAm Aesculap‐Platz78532 TuttlingenGermany
| | - Ronja A. Schierjott
- Aesculap AG, Research & DevelopmentAm Aesculap‐Platz78532 TuttlingenGermany,Ludwig‐Maximilians‐University MunichDepartment of Orthopaedic Surgery, Physical Medicine & RehabilitationCampus Grosshadern, Marchioninistrasse 1581377 MunichGermany
| | | | - Heiko Graichen
- Department for Arthroplasty and General Orthopaedic SurgeryOrthopaedic Hospital LindenloheLindenlohe 1892421 SchwandorfGermany
| | - Volkmar Jansson
- Ludwig‐Maximilians‐University MunichDepartment of Orthopaedic Surgery, Physical Medicine & RehabilitationCampus Grosshadern, Marchioninistrasse 1581377 MunichGermany
| | - Maximilian Rudert
- Department of Orthopaedic Surgery, König‐Ludwig‐HausJulius‐Maximilians‐University WürzburgBrettreichstraße 1197074 WürzburgGermany
| | - Francesco Traina
- University of MessinaVia Consolare Valeria 198124 MessinaItaly,Istituto Ortopedico RizzoliVia Giovanni Pupilli 140136 BolognaItaly
| | - Thomas M. Grupp
- Aesculap AG, Research & DevelopmentAm Aesculap‐Platz78532 TuttlingenGermany,Ludwig‐Maximilians‐University MunichDepartment of Orthopaedic Surgery, Physical Medicine & RehabilitationCampus Grosshadern, Marchioninistrasse 1581377 MunichGermany
| |
Collapse
|
50
|
Inoue D, Kabata T, Kimura H, Tsuchiya H. A prospective clinical trial to assess the accuracy of an MRI-based patient-specific acetabular instrument guide in total hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 29:65-71. [DOI: 10.1007/s00590-018-2279-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 07/23/2018] [Indexed: 12/16/2022]
|