1
|
Sonnier JH, Kemler B, Coladonato C, Paul RW, Tjoumakaris FP, Freedman KB. Surgical management of acute, high-grade acromioclavicular joint separations: a systematic review. JSES REVIEWS, REPORTS, AND TECHNIQUES 2023; 3:10-20. [PMID: 37588062 PMCID: PMC10426581 DOI: 10.1016/j.xrrt.2022.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background While a number of treatment options exist for repair of acute, high-grade acromioclavicular joint (ACJ) separation, none have emerged as the standard of care. The purpose of this study was to systematically review the literature on surgical treatment of acute, high-grade (Rockwood grades III-V) ACJ separations in order to compare outcomes between direct fixation and tendon graft ligament reconstruction. Methods A systematic review of the literature evaluating outcomes for acute ACJ separation treatment with direct fixation or free biologic tendon graft reconstruction was performed. The following databases were examined: the Cochrane Database of Systematic Reviews, the Cochrane Central Register of Controlled Trials, PubMed (1980-2021), and Embase (1980-2021). Studies were included if they reported a mean time to surgery as <6 weeks, contained >10 patients with a minimum 1-year follow-up, and reported clinical or radiographic outcomes. Results A total of 52 studies met the inclusion criteria. Seven studies reported outcomes following tendon graft ligament reconstruction (n = 128 patients). There were multiple methods of direct fixation. Thirty-three studies utilized suture button constructs (n = 1138), 16 studies used hook plates (n = 567), 2 studies used coracoclavicular screws (n = 94), 2 studies used suture fixation (n = 93), 2 studies used suture anchor (n = 55), 2 studies used suture cerclage fixation (n = 87), 1 used single multistrand titanium cable (n = 24), and 1 used K wire (n = 11). The mean follow-up Constant scores ranged from 77.5 to 97.1 in the fixation group compared to 90.3-96.6 in the tendon graft group. The mean visual analog scale scores ranged from 0 to 4.5 in the fixation group and 0.1-1 in the tendon graft group. Net CC distance ranged from 17.5 to 3.6 mm in the fixation group and 7.4-4 mm in the tendon graft group. The revision rates ranged from 0.0% to 18.18% in the direct fixation group and 5.88%-17% in the tendon graft group. Conclusion Direct fixation and tendon graft reconstruction for management of acute, high-grade ACJ separations have similar patient subjective and radiographic outcomes, as well as complication and revision rates at a minimum 1-year follow-up.
Collapse
Affiliation(s)
- John Hayden Sonnier
- Rothman Orthopaedic Institute, Division of Sports Medicine, Philadelphia, PA, USA
| | - Bryson Kemler
- Rothman Orthopaedic Institute, Division of Sports Medicine, Philadelphia, PA, USA
| | - Carlo Coladonato
- Rothman Orthopaedic Institute, Division of Sports Medicine, Philadelphia, PA, USA
| | - Ryan W. Paul
- Rothman Orthopaedic Institute, Division of Sports Medicine, Philadelphia, PA, USA
| | | | - Kevin B. Freedman
- Rothman Orthopaedic Institute, Division of Sports Medicine, Philadelphia, PA, USA
| |
Collapse
|
2
|
Pieringer A, Welter J, Fischer J, Hess F. Complications following arthroscopic-assisted coracoclavicular stabilization in patients with unstable lateral clavicle fractures. Arch Orthop Trauma Surg 2023:10.1007/s00402-023-04769-2. [PMID: 36633665 DOI: 10.1007/s00402-023-04769-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 01/05/2023] [Indexed: 01/13/2023]
Abstract
PURPOSE Lateral clavicle fractures are unstable and prone to nonunions, which is why they are often treated surgically rather than conservatively. Despite the variety of surgical techniques found in the literature, the best method for treating this rare fracture type has not yet been determined. Our case series aimed to describe a coracoclavicular (CC) reconstruction technique and to assess complications and patient outcomes 1 year postoperatively. METHODS Nineteen patients who underwent surgery for an unstable lateral clavicle fracture (IIB, IIC, IID) with a suture button device (Dog Bone, Arthrex, Inc., Naples, FL, USA) were available for clinical and radiological follow-up. The assessments included the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES) score, the Constant Score (CS), the Subjective Shoulder Value (SSV), as well as the ipsilateral and contralateral coracoclavicular distance. RESULTS The median age was 50 years (IQR 28-59), 13 (68.4%) were male and the delay to surgery was 5 days (IQR 2-9). The median clinical scores were 100 (ASES), 91 (CS), and 95 (SSV). The CC distance improved postoperatively (p = 0.003). However, nonunion occurred in 3 (15.8%) patients, 5 (26.3%) had other complications, and 5 (26.3%) needed revision surgery (4 plate removals and 1 pseudoarthrosis). The overall complication rate was 36.8%. CONCLUSION Restoring the CC ligaments alone could not reliably achieve fracture stability, with more than one-third of cases in this series experiencing major complications. Given the high revision and nonunion rates, we do not recommend this type of surgical technique.
Collapse
Affiliation(s)
| | - JoEllen Welter
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Janic Fischer
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland
| | - Florian Hess
- Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland.
| |
Collapse
|
3
|
Combination of Surgical Techniques Restores Multidirectional Biomechanical Stability of Acromioclavicular Joint. Arthroscopy 2022; 38:1774-1783. [PMID: 34920006 DOI: 10.1016/j.arthro.2021.11.051] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 11/22/2021] [Accepted: 11/30/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE To measure the multiaxial stability of the acromioclavicular joint before and after transection of the acromioclavicular capsule and coracoclavicular ligaments and after sequential repair of acromioclavicular and coracoclavicular ligaments. METHODS Biomechanical testing was performed on fresh-frozen human cadaveric shoulders (N = 6). Translational and rotational stability in the vertical and horizontal planes was measured in intact specimens, after transecting the acromioclavicular and coracoclavicular ligaments, and after sequentially performing the following procedures: single-bundle coracoclavicular repair (CCR), modified Weaver-Dunn procedure (WD), and acromioclavicular stabilization (ACS). RESULTS Resecting the acromioclavicular and coracoclavicular significantly reduced translational stiffness in the inferior and anteroposterior directions, as well as rotational stiffness about the vertical and anteroposterior axes. All 3 surgical procedures increased inferior translational stiffness relative to the intact condition (Intact: 38 ± 9 N/mm, CCR: 54 ± 23 N/mm (P = .03), CCR+WD 52 ± 20 N/mm (P = .07), CCR ± WD+ACS 50 ± 21 N/mm (P = .17)). However, the combination of CCR, modified WD, and ACS resulted in the greatest increase in stiffness in internal rotation (Intact: 12.5 ± 7.4 cNm/deg, CCR: 1.2 ± 1.1 cNm/deg, CCR+WD 7.2 ± 3.0 N∗m/deg [P = .023], CCR+WD+ACS 11.6 ± 4.9 cNm/deg [P = .055]). CONCLUSIONS The cumulative stability of CCR, WD reconstruction, and ACS appears to be additive. Our findings provide a biomechanical justification for combining all three techniques. Biomechanical studies assessing the performance of various acromioclavicular repairs and reconstructions should therefore incorporate multiaxial testing in their protocols. CLINICAL RELEVANCE Multiple points of fixation that provide multidirectional stability have the potential to improve clinical outcomes and reduce failure rates of acromioclavicular joint repair or stabilization.
Collapse
|
4
|
Gawel RJ, D'Amore T, Otlans PT, Rao S, Cohen SB, Ciccotti MG. Criteria for return to play after operative management of acromioclavicular joint separation: a systematic review. JSES REVIEWS, REPORTS, AND TECHNIQUES 2022; 2:140-148. [PMID: 37587962 PMCID: PMC10426690 DOI: 10.1016/j.xrrt.2021.11.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Background Acromioclavicular (AC) joint separation is a common cause of shoulder injury among athletes. High-grade injuries may require operative fixation, and comprehensive return-to-play guidelines have not yet been established. The purpose of this study was to summarize criteria for return to play after operative management of AC joint separation. Methods A systematic review of the literature was performed from January 1999 to April 2020 to evaluate clinical evidence regarding criteria for return to play after operative management of isolated AC joint separation. Results Sixty-three studies with at least 1 explicitly stated return-to-play criterion were identified out of an initial database search of 1253 published articles. Eight separate categories of return-to-play criteria were identified, the most common of which was time from surgery (95.2%). Return-to-play timelines ranged from 2 to 12 months, the most common timeline being 6 months (37.8%). Only 4 (6.3%) studies used conditional criteria to guide return to play, which included range of motion, strength, clinical stability, radiographic stability, functional assessment, safety assessment, and hardware removal. Conclusion Most published studies use only time-based criteria for return to play after surgery for AC joint separation, and only a small number of studies use additional subjective or objective criteria. While this systematic review helps provide a foundation for developing a comprehensive return-to-play checklist, further investigation is needed to establish safe and effective guidelines that will enable athletes to safely return to sport and minimize the recurrence of injury.
Collapse
Affiliation(s)
- Richard J. Gawel
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| | - Taylor D'Amore
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| | - Peters T. Otlans
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| | - Somnath Rao
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| | - Steven B. Cohen
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| | - Michael G. Ciccotti
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
5
|
Furuhata R, Matsumura N, Udagawa K, Oki S, Morioka H. Residual coracoclavicular separation after plate fixation for distal clavicle fractures: comparison between fracture patterns. JSES Int 2021; 5:840-845. [PMID: 34505093 PMCID: PMC8411066 DOI: 10.1016/j.jseint.2021.04.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background Plate fixation is an established treatment for Neer type II and V distal clavicle fractures; however, residual coracoclavicular (C-C) separation after osteosynthesis for unstable distal clavicle fractures has rarely been discussed. This study aimed to reveal the extent of postoperative C-C separation after plate fixation for distal clavicle fractures and to evaluate the relationship between residual C-C separation and the risk of postoperative complications. Methods We retrospectively reviewed 60 patients with a displaced distal clavicle fracture that was treated with a Scorpion plate without C-C reconstruction and successfully united. Distal clavicle fractures were divided as per the Neer classification into type IIA (12 patients), IIB (36 patients), and V (12 patients) groups. The modified C-C distance ratio at the time of injury and after bone union, and the postoperative complications (plate-related pain, delayed union, infection, and contracture) were compared among the three groups. Results The mean postoperative modified C-C distance ratio was 115.0% ± 12.0%; this ratio was significantly larger in the type IIB and V groups than in the type IIA group (P = .021 and P = .006, respectively). However, there was no significant difference in the frequency of postoperative complications among the three groups. Conclusions Our study demonstrated that a certain degree of C-C separation remained after plate fixation for Neer type II and V distal clavicle fractures, even when bone union was achieved. The postoperative residual C-C separation was greater for the type IIB and V groups than for the type IIA group; however, this difference may not affect postoperative complications.
Collapse
Affiliation(s)
- Ryogo Furuhata
- Department of Orthopaedic Surgery, National Hospital Organization Tokyo Medical Centre, Meguro-ku, Tokyo, Japan.,Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Noboru Matsumura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Kazuhiko Udagawa
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan.,Department of Emergency and Critical Care Medicine, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Satoshi Oki
- Department of Orthopaedic Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya-shi, Tochigi, Japan
| | - Hideo Morioka
- Department of Orthopaedic Surgery, National Hospital Organization Tokyo Medical Centre, Meguro-ku, Tokyo, Japan
| |
Collapse
|
6
|
Stand-alone coracoclavicular suture repair achieves very good results in unstable distal clavicle fractures at a minimum follow-up of 1 year. J Shoulder Elbow Surg 2021; 30:2090-2096. [PMID: 33486065 DOI: 10.1016/j.jse.2020.11.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 11/19/2020] [Accepted: 11/25/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND The treatment of unstable (Neer type IIB and V) extra-articular distal clavicle fractures remains challenging, especially when encountering a small lateral fragment which does not allow for sufficient screw purchase. It was the purpose of this study to present the clinical and radiologic outcome of a consecutive series of patients treated by a stand-alone coracoclavicular stabilization using a so-called cow-hitch technique with a suture anchor. METHODS Nineteen patients were treated with a specific surgical technique for distal clavicle fractures (11 left, 8 right) with either rupture or bony avulsion of the coracoclavicular ligaments. Fourteen patients were examined in our outpatient clinic for the purpose of this study after a mean follow-up of 5 years (1-12.2 years). The examination included scoring according to Constant Murley score (CMS), the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), the Subjective Shoulder Value (SSV), and follow-up radiographs. Two additional patients were amenable to a telephone interview. RESULTS All patients reported very good subjective results, with a mean SSV of 92% and a mean ASES score of 96%. The CMS resulted in average absolute values of 92 points. Fractures consolidated in 95% of cases. One patient developed an asymptomatic pseudarthrosis. The coracoclavicular distance was restored from 21 mm preoperatively to 11 mm at the final follow-up and finally showed an average side-to-side difference of +1.8 mm. Sports activities were fully resumed after an average of 4.7 months. CONCLUSION The coracoclavicular stand-alone cow-hitch suture repair for unstable distal clavicle fractures is a minimally invasive fixation technique without prominent hardware that allows for an anatomic reduction and stable fixation with a low complication and high bony union rate. Both radiographic and clinical long-term results are very satisfactory.
Collapse
|
7
|
Comparison of single versus double TightRope system in the treatment of acute acromioclavicular joint dislocation. J Shoulder Elbow Surg 2021; 30:1915-1923. [PMID: 33160026 DOI: 10.1016/j.jse.2020.10.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 09/20/2020] [Accepted: 10/07/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reconstruction of the coracoclavicular (CC) ligament using a single TightRope (ST) system has some complications. We attempted to use a double TightRope (DT) system to reduce complications and obtain the ideal therapeutic effect. PURPOSE This investigation aimed to compare the ST and DT systems in terms of efficacy and safety in treating acromioclavicular (AC) joint dislocation. METHODS Sixty-six cases of acute AC joint dislocation between January 2013 and January 2018 were retrospectively reviewed. All patients were divided into 2 groups based on treatment with the ST or DT system. Patients were evaluated radiologically and clinically using the Disability of Arm, Shoulder, and Hand, Constant, and visual analog scale scores as clinical outcome measures at 1 day, 3 weeks, 6 weeks, 3 months, 6 months, 1 year, and 2 years after surgery. The CC distance and displacement ratio were assessed radiologically. RESULTS The mean follow-up period was 49 months. Satisfactory clinical outcomes were obtained after CC fixation in both groups. No intergroup difference was found regarding the visual analog scale (P = .80), Disability of Arm, Shoulder, and Hand (P = .42), or Constant score (P = .28) at 2 years. However, there was a significant difference in the displacement ratio at 6 weeks (P < .0001), 3 months (P < .0001), 6 months (P < .0001), 1 year (P < .0001), and 2 years (P < .0001) postoperatively between the 2 groups. There were 3 complications in the ST group, including 1 case of secondary coracoid fracture, 1 case of AC joint arthrosis combined with ossification of the CC ligaments, and 1 case of clavicular erosion. All complications occurred in the ST group. CONCLUSIONS Both surgical methods are effective in treating AC joint dislocation, but the DT system is more reliable for reduction maintenance.
Collapse
|
8
|
Biologic and synthetic ligament reconstructions achieve better functional scores compared to osteosynthesis in the treatment of acute acromioclavicular joint dislocation. Knee Surg Sports Traumatol Arthrosc 2021; 29:2175-2193. [PMID: 32797247 DOI: 10.1007/s00167-020-06217-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 08/06/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To systematically review the outcomes of surgical treatments of acute acromioclavicular joint dislocation. METHODS Studies were identified by electronic databases (Ovid, PubMed). All studies reporting functional and radiological outcomes of surgical treatments of acute acromioclavicular joint dislocations were included. Following data were extracted: authors and year, study design, level of evidence, number of patients, age, classification of acromioclavicular joint dislocation, time to surgery, surgical technique, follow-up, clinical and imaging outcomes, complications, and failures. Descriptive statistics was used, when a data pooling was not possible. Comparable outcomes were pooled to generate summary outcomes reported as frequency-weighted values. Quality appraisal was assessed through the MINORS checklist. RESULTS One hundred and thirty-three studies were included for a total of 4473 shoulders. Mean age of participants was 36.9 years. Mean follow-up was 42.06 months. Arthroscopy showed better ASES (p < 0.0001) and lower VAS pain score (p = 0.0249) compared to an open approach. Biologic and synthetic reconstructions demonstrated better results over osteosynthesis techniques. Biologic techniques showed overall better Constant (p = 0.0001) and DASH (p = 0.0215) scores, while synthetic reconstruction showed better UCLA score (p = 0.0001). Among suture buttons, triple button showed overall better results in Constant (p = 0.0001) and VAS (p = 0.0001) scores, while better results in DASH score (p = 0.0003) were achieved by 2 double button techniques. Overall, the level of evidence was low. CONCLUSION Biological and synthetic reconstructions achieved better functional scores compared to osteosynthesis. Among suture buttons, the triple button showed better functional performance. LEVEL OF EVIDENCE IV.
Collapse
|
9
|
Yoo YS, Khil EK, Im W, Jeong JY. Comparison of Hook Plate Fixation Versus Arthroscopic Coracoclavicular Fixation Using Multiple Soft Anchor Knots for the Treatment of Acute High-Grade Acromioclavicular Joint Dislocations. Arthroscopy 2021; 37:1414-1423. [PMID: 33340675 DOI: 10.1016/j.arthro.2020.12.189] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 12/03/2020] [Accepted: 12/05/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE To compare the clinical and radiologic outcomes of arthroscopically assisted coracoclavicular (CC) fixation using multiple soft anchor knots versus hook plate fixation in patients with acute high-grade Rockwood type III and V acromioclavicular (AC) joint dislocations. METHODS This retrospective study included 22 patients with acute Rockwood type III and V AC joint dislocations who underwent arthroscopic fixation or hook plate fixation surgery between February 2016 and March 2018. Patients were categorized into 2 groups: arthroscopically assisted CC fixation using multiple soft anchor knots group (AR, n = 12) and hook plate fixation group (HO, n = 10). We measured the CC distances (CCDs) and CCD ratio at 6 months, 1 year, and last follow-up postoperatively to compare the radiologic results between the groups. Clinical outcomes were assessed at 1 year postoperatively and at the last follow-up using the Visual Analog Scale, American Shoulder and Elbow Surgeons (ASES) scores, and Shoulder Pain and Disability Index (SPADI) scores, and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Magnetic resonance imaging after hook plate removal was used to evaluate the healing ligaments and tendon-bone interface. RESULTS The patients in the AR group had better ASES, SPADI, and Quick DASH scores than the patients in the HO group at 1 year postoperatively and at last follow-up. The CCD and CCD ratio were significantly better in the AR group than in the HO group at the last follow-up period (P = .007/0.029). Magnetic resonance imaging findings showed grade I in 60% of patients in the AR group and grade III in 60% of patients in the HO group. AC joint arthritic change was observed in 40% of the HO group. CONCLUSIONS The CC fixation method using multiple soft anchor knots showed satisfactory results and had superior CC ligament healing ability and maintenance of CCD than hook fixation. LEVEL OF EVIDENCE Level III, retrospective therapeutic comparative investigation.
Collapse
Affiliation(s)
- Yon-Sik Yoo
- Camp 9 Orthopedic Clinic, Gyeonggi-do, Republic of Korea
| | - Eun Kyung Khil
- Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do, Republic of Korea
| | - Wooyoung Im
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do, Republic of Korea
| | - Jeung Yeol Jeong
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Gyeonggi-do, Republic of Korea.
| |
Collapse
|
10
|
Salazar BP, Chen MJ, Bishop JA, Gardner MJ. Outcomes after locking plate fixation of distal clavicle fractures with and without coracoclavicular ligament augmentation. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2021; 31:473-479. [PMID: 32949271 DOI: 10.1007/s00590-020-02797-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 09/10/2020] [Indexed: 01/11/2023]
Abstract
BACKGROUND The need for coracoclavicular (CC) ligament augmentation when performing locking plate fixation of unstable distal clavicle fractures is controversial. The purpose of this study was to compare the results after locking plate fixation for treatment of Neer type-II and type-V distal clavicle fractures with and without suture suspensory augmentation of the CC ligaments. METHODS This was a retrospective case series of all Neer type-II and type-V distal clavicle fractures treated with locking plates at a single Level I trauma center. Patients were separated into locking plate-only and locking plate with CC ligament augmentation groups. Postoperative complications and fracture healing rates were recorded. Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) scores were recorded as functional outcomes during follow-up phone interviews. Standard descriptive statistics were performed. RESULTS Sixteen patients were treated with locking plate fixation-only, and seven patients were treated with additional CC ligament augmentation. There was a similar distribution of Neer fracture types with each group. All fractures in both groups went onto union without loss of reduction or implant failure. There were no cases of infection or wound complications in either group. QuickDASH scores were comparable between locking plate-only fixation (mean 4.1 ± 3.9) and additional suspensory suture fixation (mean 4.5 ± 3.6). CONCLUSION This comparative study of Neer type-II and type-V distal clavicle fractures demonstrated comparable outcomes after locking plate fixation with and without CC ligament augmentation. CC ligament augmentation may not be necessary when treating unstable distal clavicle fractures if locking plate fixation is used.
Collapse
Affiliation(s)
- Brett P Salazar
- Department of Orthopaedic Surgery, Stanford University Medical Center, 450 Broadway Street, Pavilion C, 4th Floor, Redwood City, CA, 94063-6342, USA.
| | - Michael J Chen
- Department of Orthopaedic Surgery, Stanford University Medical Center, 450 Broadway Street, Pavilion C, 4th Floor, Redwood City, CA, 94063-6342, USA
| | - Julius A Bishop
- Department of Orthopaedic Surgery, Stanford University Medical Center, 450 Broadway Street, Pavilion C, 4th Floor, Redwood City, CA, 94063-6342, USA
| | - Michael J Gardner
- Department of Orthopaedic Surgery, Stanford University Medical Center, 450 Broadway Street, Pavilion C, 4th Floor, Redwood City, CA, 94063-6342, USA
| |
Collapse
|
11
|
Seo JB, Kim SJ, Ham HJ, Yoo JS. Comparison between hook plate fixation with and without coracoclavicular ligament suture for acute acromioclavicular joint dislocations. J Orthop Surg (Hong Kong) 2020; 28:2309499020905058. [PMID: 32336204 DOI: 10.1177/2309499020905058] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Hook plates are widely used for repair of acromioclavicular joint (ACJ) dislocations. However, it is unclear whether repair of torn coracoclavicular (CC) ligament is necessary. The purpose of this study was to evaluate the outcomes of the hook plate fixation with direct CC ligament repair for acute ACJ dislocation in comparison with the hook plate fixation without direct CC ligament repair. METHODS The study included 120 patients with acute ACJ dislocations who underwent surgery. The patients were divided into 73 patient groups with Arbeitsgemeinschaft für Osteosynthesefragen (AO) hook plate fixation and direct CC ligament repair and 47 patient groups without direct CC ligament repair. For clinical assessments, the American Shoulder and Elbow Surgeons score, constant score, and time for implant removal were recorded. The corcoclavicular distance (CCD) and the CCD ratio were used for the evaluation of reduction. Typical reported complications, such as secondary dislocation, implant failure or loosening, peri-implant fracture, acromion osteolysis, and postoperative ACJ arthrosis, were also analyzed. RESULTS There were no differences in the clinical outcomes between the two groups. There was no difference in the timing of implant removal between the two groups. The last follow-up CCD was not statistically significant between group with direct CC ligament repair and without repair (9.1 ± 3.3 vs. 9.0 ± 2.8, respectively, p > 0.05). The last follow-up CCD ratio showed significant differences between the two groups (12.6 ± 25.5% vs. 26.3 ± 39.7, respectively, p < 0.05). There was no statistically significant difference in the complication rate between the two groups. CONCLUSION The hook plate fixation with direct CC ligament repair group was better for maintenance of reduction than that of the hook plate fixation without direct CC ligament repair group. Although, there were no differences of clinical outcomes and complications between two groups. LEVEL OF EVIDENCE Level III, Retrospective Study.
Collapse
Affiliation(s)
- Joong-Bae Seo
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Cheonan, Republic of Korea
| | - Seong-Jun Kim
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Cheonan, Republic of Korea
| | - Hee-Jung Ham
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Cheonan, Republic of Korea
| | - Jae-Sung Yoo
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Cheonan, Republic of Korea
| |
Collapse
|
12
|
Argekar HG, Sahu D. Under Coracoid-through Clavicle Suture Fixation in Type 2 Distal Clavicle Fracture. J Orthop Case Rep 2020; 10:13-16. [PMID: 32953647 PMCID: PMC7476690 DOI: 10.13107/jocr.2020.v10.i02.1676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction Surgical management of Neer type 2 distal clavicle fractures may include tension band wiring, pre-contoured plate, hook plate or indirect fixation of coracoclavicular space by Endobutton, suture anchors, or Tightrope devices. We present our technique of suture and Mersilene tape fixation by passing them through the clavicle and under the coracoid which is a form of indirect fixation. Technique The fracture and the coracoid are exposed through a horizontal skin incision. The Mersilene tape and Ethibond suture are looped under the coracoid and then one limb of each is passed through the medial hole and then through the lateral hole to exit inferiorly and then tied underneath the clavicle, while the fracture is reduced. Conclusion Direct fixation by means of plate has good outcomes though high complication rate. Indirect fixation by means of Endobutton and Tightrope devices has shown successful outcome with less side effects. Our method of fixation by Ethibond suture and Mersilene tape is inexpensive while having the same principles of internal fixating the clavicle to the coracoid while the fracture heals.
Collapse
Affiliation(s)
- Harshad G Argekar
- Department of Orthopaedics, Dr. R.N. Cooper Municipal Hospital and HBT Medical College, Juhu Mumbai, Maharashtra. India
| | - Dipit Sahu
- Department of Orthopaedics, Dr. R.N. Cooper Municipal Hospital and HBT Medical College, Juhu Mumbai, Maharashtra. India
| |
Collapse
|
13
|
Jeong JY, Chun YM. Treatment of acute high-grade acromioclavicular joint dislocation. Clin Shoulder Elb 2020; 23:159-165. [PMID: 33330252 PMCID: PMC7714286 DOI: 10.5397/cise.2020.00150] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 05/06/2020] [Indexed: 02/07/2023] Open
Abstract
Acromioclavicular (AC) joint dislocations account for about 9% of shoulder injuries. Among them, acute high-grade injury following high-energy trauma accounts for a large proportion of patients requiring surgical treatment. However, there is no gold standard procedure for operative treatment of acute high-grade AC joint injury, and several different procedures have been used for this purpose in clinical practice. This review article summarizes the most recent and relevant surgical options for acute high-grade AC joint dislocation patients and the outcomes of each treatment type.
Collapse
Affiliation(s)
- Jeung Yeol Jeong
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Korea
| | - Yong-Min Chun
- Department of Orthopedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
14
|
Seo JB, Lee DH, Kim KB, Yoo JS. Coracoid clavicular tunnel angle is related with loss of reduction in a single-tunnel coracoclavicular fixation using a dog bone button in acute acromioclavicular joint dislocation. Knee Surg Sports Traumatol Arthrosc 2019; 27:3835-3843. [PMID: 31542815 DOI: 10.1007/s00167-019-05731-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 09/17/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE Despite the high failure rates of techniques used to maintain the reduction of single-tunnel coracoclavicular (CC) fixation, analyses of the etiology of loss of reduction related to surgical techniques are limited. Therefore, it was hypothesized that the initial coracoclavicular tunnel angle was related to loss of reduction in the single-tunnel technique for AC joint dislocation. This study aimed to evaluate the clinical and radiological outcomes of arthroscopic single-tunnel CC suture button fixation according to the initial coracoclavicular tunnel angle. METHODS Thirty-two consecutive patients who underwent arthroscopic single-tunnel CC suture button fixation for AC joint dislocation from 2014 to 2018 were enrolled. The tunneling-first technique was used in the first 11 patients, while the reduction-first technique was used in the remaining 22 consecutive patients. For clinical assessments, the American Shoulder and Elbow Surgeons (ASES) score and Korean Shoulder Score (KSS) were recorded. For radiological evaluation, coracoclavicular distance ratio, coracoclavicular tunnel angle, coracoid, and clavicular tunnel widths were measured. RESULTS The ASES score did not differ significantly between the two groups (n.s.). However, the KSS was significantly better in the reduction-first group (p = 0.031). No significant intergroup differences were observed in the pre- and postoperative coracoclavicular distance ratio. However, at the last follow-up, loss of coracoclavicular distance ratio was significantly smaller in the reduction-first group (p < 0.001). At the final follow-up, loss of the coracoclavicular distance ratio was positively correlated with the postoperative coracoclavicular tunnel angle (p < 0.001, Spearman's rho correlation coefficient = 0.602). The final follow-up clavicular tunnel width was also significantly smaller in the reduction-first group (p = 0.002). Finally, the last follow-up clavicular tunnel width was positively correlated with the postoperative coracoclavicular tunnel angle (p = 0.008, Spearman's rho correlation coefficient = 0.459). CONCLUSION The reduction-first technique showed better clinical and radiological outcomes than the tunneling-first technique in single-tunnel CC fixation for AC joint dislocation. A large postoperative coracoclavicular tunnel angle was associated with loss of reduction and clavicular tunnel widening. Therefore, obtaining a straight coracoclavicular tunnel angle is crucial for achieving better outcomes and minimizing loss of reduction. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Joong-Bae Seo
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Manghyangro 201, Dongnam-gu, Cheonan, Chungnam, 330-715, Republic of Korea
| | - Dong-Ho Lee
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Manghyangro 201, Dongnam-gu, Cheonan, Chungnam, 330-715, Republic of Korea
| | - Kyu-Beom Kim
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Manghyangro 201, Dongnam-gu, Cheonan, Chungnam, 330-715, Republic of Korea
| | - Jae-Sung Yoo
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Manghyangro 201, Dongnam-gu, Cheonan, Chungnam, 330-715, Republic of Korea.
| |
Collapse
|
15
|
Lee SJ, Yoo YS, Kim YS, Jang SW, Kim J, Kim SJ, Kim BS, Jung KH, Varshney A. Arthroscopic Coracoclavicular Fixation Using Multiple Low-Profile Devices in Acute Acromioclavicular Joint Dislocation. Arthroscopy 2019; 35:14-21. [PMID: 30455087 DOI: 10.1016/j.arthro.2018.07.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 06/27/2018] [Accepted: 07/05/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE To introduce an arthroscopically assisted coracoclavicular (CC) fixation technique using multiple low-profile devices to evaluate the clinical and radiologic outcomes in patients with acute high-grade acromioclavicular (AC) joint dislocation. METHODS Between July 2014 and September 2015, cases of AC joint dislocation that were treated with arthroscopic CC fixation using multiple low-profile devices with a minimum follow-up of 24 months were included. We measured the vertical coracoclavicular distance (CCD) on the anteroposterior view and the horizontal acromioclavicular distance on 3-dimensional computed tomography images to evaluate the changes in radiologic outcomes before and after surgery. We compared final radiologic outcomes between initial AC reduction groups based on hierarchical clustering. Clinical outcomes were evaluated using the Constant-Murley score. RESULTS We enrolled 27 patients in total, and the mean follow-up period was 27.2 months. The mean CCD of the injured shoulder was 13.68 ± 3.98 mm preoperatively and decreased to 5.72 ± 1.68 mm immediately postoperatively but increased to 7.32 ± 2.29 mm at last follow-up (P = .07). Horizontal displacement of the distal clavicle was 1.1 ± 1.0 mm immediately postoperatively but decreased to 0.9 ± 0.6 mm at last follow-up (P < .05). In particular, in the 2 groups that were determined using the hierarchical cluster analysis, patients with excellent recovery of the initial CCD (20 patients) showed less of an increase in the CCD at last follow-up than did those in the other group (7 patients) (P < .001). The Constant-Murley score was 93.5 ± 2.7 points on the injured side at last follow-up (P = .074). CONCLUSIONS Our CC fixation technique with multiple low-profile devices exhibited satisfactory clinical and radiologic outcomes. In particular, ensuring good initial recovery of the CCD and the precise placement and location of the AC joints was important in maintaining the proper AC position at the final follow-up. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
- Seung-Jin Lee
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Hwaseong, Republic of Korea
| | - Yon-Sik Yoo
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Hwaseong, Republic of Korea.
| | - Yoon-Sang Kim
- School of Computer Science and Engineering, Korea University of Technology and Education, Cheonan, Republic of Korea
| | - Seong-Wook Jang
- School of Computer Science and Engineering, Korea University of Technology and Education, Cheonan, Republic of Korea
| | - Jeehyoung Kim
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Republic of Korea
| | - Sung-Jae Kim
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Hwaseong, Republic of Korea
| | - Byung-Su Kim
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Hwaseong, Republic of Korea
| | - Koo-Hyun Jung
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Hwaseong, Republic of Korea
| | - Ankit Varshney
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Medical College of Hallym University, Hwaseong, Republic of Korea
| |
Collapse
|
16
|
Fereydouni N, Darroudi M, Movaffagh J, Shahroodi A, Butler AE, Ganjali S, Sahebkar A. Curcumin nanofibers for the purpose of wound healing. J Cell Physiol 2018; 234:5537-5554. [DOI: 10.1002/jcp.27362] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 08/17/2018] [Indexed: 12/15/2022]
Affiliation(s)
- Narges Fereydouni
- Student Research Committee, Department of Modern Sciences and Technologies, Faculty of Medicine Mashhad University of Medical Sciences Mashhad Iran
| | - Majid Darroudi
- Nuclear Medicine Research Center Mashhad University of Medical Sciences Mashhad Iran
- Department of Modern Sciences and Technologies School of Medicine, Mashhad University of Medical Sciences Mashhad Iran
| | - Jebrail Movaffagh
- Department of Pharmaceutical Nanotechnology School of Pharmacy, Mashhad University of Medical Sciences Mashhad Iran
- Targeted Drug Delivery Research Center Pharmaceutical Technology Institute, Mashhad University of Medical Sciences Mashhad Iran
| | - Azadeh Shahroodi
- Department of Pharmaceutical Nanotechnology School of Pharmacy, Mashhad University of Medical Sciences Mashhad Iran
- Targeted Drug Delivery Research Center Pharmaceutical Technology Institute, Mashhad University of Medical Sciences Mashhad Iran
| | | | - Shiva Ganjali
- Department of Medical Biotechnology School of Medicine, Mashhad University of Medical Sciences Mashhad Iran
| | - Amirhossein Sahebkar
- Neurogenic Inflammation Research Center Mashhad University of Medical Sciences Mashhad Iran
- Biotechnology Research Center Pharmaceutical Technology Institute, Mashhad University of Medical Sciences Mashhad Iran
- School of Pharmacy, Mashhad University of Medical Sciences Mashhad Iran
| |
Collapse
|
17
|
Seo JB, Heo K, Kim SJ, Jung JU, Yoo JS. Arthroscopic Acromioclavicular Fixation With Suture Tape Augmentation After Coracoclavicular Fixation With Dog Bone Button: Surgical Technique. Arthrosc Tech 2018; 7:e1197-e1203. [PMID: 30533369 PMCID: PMC6261742 DOI: 10.1016/j.eats.2018.08.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 08/02/2018] [Indexed: 02/03/2023] Open
Abstract
An arthroscopic technique for the surgical treatment of acute acromioclavicular (AC) joint injuries is presented in this study. This procedure aims to achieve both vertical and horizontal stability through the healing of both coracoclavicular (CC) and AC ligaments. As a routine maneuver, arthroscopic CC stabilization was applied using the dog bone button to obtain only vertical stability. Additional arthroscopic AC joint fixation with suture tape augmentation is simple and easy and provides a safe technique to achieve horizontal stability of the joint and to increase the vertical stability to minimize the complications of standard CC reconstruction techniques.
Collapse
Affiliation(s)
| | | | | | | | - Jae-Sung Yoo
- Address correspondence to Jae-Sung Yoo, M.D., Department of Orthopaedic Surgery, Dankook University College of Medicine, 119, Dandae-ro, Dongnam-gu, Cheonan-si, Chungnam 330-715, Republic of Korea.
| |
Collapse
|
18
|
Morgan EN, Means KR, Paez AG, Parks BG, Innis PC. Suture-Button Device Stabilization Following Ring Finger Ray Amputation: A Comparative Cadaver Study. Hand (N Y) 2018; 13:435-440. [PMID: 28665145 PMCID: PMC6081778 DOI: 10.1177/1558944717715104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The purpose of this study was to determine whether placing the suture-button device between the long and small finger metacarpals following ring finger ray amputation may better close the intermetacarpal gap and allow early range of motion without increasing the risk of malrotation than soft tissue repair alone. METHODS We performed ray amputation of the ring finger of 14 cadaver specimens by performing an osteotomy of the base of the ring finger metacarpal and then excising the remainder of the digit. We first performed a soft tissue repair of the transverse metacarpal ligaments and then cycled the fingers in simulated active flexion and extension on a custom computer-controlled device to re-create 6 weeks of range of motion. We then placed a suture-button device across the long and small finger metacarpals and tested the specimens again, thereby using each hand as an internal control. RESULTS The distance between the ring and small finger metacarpals was reduced following suture-button device placement compared with the initial control; this spacing was maintained following complete cycling of the fingers. The angle between the metacarpals was divergent following soft tissue repair, and then became slightly convergent after insertion of the suture-button device. None of the hands developed clinically relevant scissoring of the digits before or after application of the suture-button device. CONCLUSIONS The suture-button device provides stable fixation to withstand early range of motion following ring finger ray amputation and significantly closes the gap and angle between the adjacent metacarpals without causing scissoring.
Collapse
Affiliation(s)
- Emily N. Morgan
- Walter Reed National Military Medical Center, Bethesda, MD, USA,The Curtis National Hand Center, Baltimore, MD, USA
| | - Kenneth R. Means
- The Curtis National Hand Center, Baltimore, MD, USA,Kenneth R. Means Jr, care of Anne Mattson, The Curtis National Hand Center, MedStar Union Memorial Hospital, 3333 North Calvert Street, Baltimore, MD 21218, USA.
| | | | | | | |
Collapse
|
19
|
Acromioclavicular joint dislocation: a Dog Bone button fixation alone versus Dog Bone button fixation augmented with acromioclavicular repair-a finite element analysis study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 28:1095-1101. [PMID: 29557509 DOI: 10.1007/s00590-018-2186-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Accepted: 03/13/2018] [Indexed: 12/17/2022]
Abstract
BACKGROUND Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). MATERIALS AND METHODS A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. RESULTS The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. CONCLUSION This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.
Collapse
|
20
|
Li W, Wu D, Tan J, Liu Z, Lu L, Zhou C. A gene-activating skin substitute comprising PLLA/POSS nanofibers and plasmid DNA encoding ANG and bFGF promotes in vivo revascularization and epidermalization. J Mater Chem B 2018; 6:6977-6992. [DOI: 10.1039/c8tb02006j] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A gene-activated porous nanofibrous scaffold for effectively promoting vascularization, epidermalization and dermal wound healing by sustained release of dual plasmid DNAs.
Collapse
Affiliation(s)
- Wenqiang Li
- Department of Materials Science and Engineering
- Jinan University
- Guangzhou 510632
- China
- College of Life Science and Technology
| | - Dongwei Wu
- Department of Materials Science and Engineering
- Jinan University
- Guangzhou 510632
- China
| | - Jianwang Tan
- Department of Materials Science and Engineering
- Jinan University
- Guangzhou 510632
- China
| | - Zhibin Liu
- Department of Materials Science and Engineering
- Jinan University
- Guangzhou 510632
- China
| | - Lu Lu
- Department of Materials Science and Engineering
- Jinan University
- Guangzhou 510632
- China
- Engineering Research Center of Artificial Organs and Materials
| | - Changren Zhou
- Department of Materials Science and Engineering
- Jinan University
- Guangzhou 510632
- China
- Engineering Research Center of Artificial Organs and Materials
| |
Collapse
|
21
|
Mo Y, Guo R, Zhang Y, Xue W, Cheng B, Zhang Y. Controlled Dual Delivery of Angiogenin and Curcumin by Electrospun Nanofibers for Skin Regeneration. Tissue Eng Part A 2017; 23:597-608. [DOI: 10.1089/ten.tea.2016.0268] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Affiliation(s)
- Yunfei Mo
- Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Jinan University, Guangzhou, China
- Department of Biomedical Engineering, Jinan University, Guangzhou, China
| | - Rui Guo
- Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Jinan University, Guangzhou, China
- Department of Biomedical Engineering, Jinan University, Guangzhou, China
| | - Yi Zhang
- Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Jinan University, Guangzhou, China
- Department of Biomedical Engineering, Jinan University, Guangzhou, China
| | - Wei Xue
- Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Jinan University, Guangzhou, China
- Department of Biomedical Engineering, Jinan University, Guangzhou, China
| | - Biao Cheng
- Department of Plastic Surgery, Guangzhou General Hospital of Guangzhou Military Command, Guangzhou, China
| | - Yuanming Zhang
- Department of Chemistry, Jinan University, Guangzhou, China
| |
Collapse
|
22
|
Cho CH, Jung JH, Kim BS. Coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures. J Shoulder Elbow Surg 2017; 26:804-808. [PMID: 27914840 DOI: 10.1016/j.jse.2016.09.048] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Revised: 09/18/2016] [Accepted: 09/29/2016] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study was to evaluate the radiologic and clinical outcomes of coracoclavicular (CC) stabilization using a suture button device for Neer type IIB lateral clavicle fractures. METHODS Eighteen consecutive patients with Neer type IIB fractures were treated with CC stabilization using a TightRope device (Arthrex, Naples, FL, USA). The mean follow-up period was 46.6 months (range, 24-75 months). Radiologic outcomes were assessed using serial plain radiographs. Clinical outcomes were evaluated using the visual analog scale pain score; University of California, Los Angeles score; American Shoulder and Elbow Surgeons score; and subjective shoulder value. Intraoperative and postoperative complications were also evaluated. RESULTS Of the 18 cases, 17 (94.4%) showed complete bony union. The mean final visual analog scale pain score was 1.1; University of California, Los Angeles score, 31.3; American Shoulder and Elbow Surgeons score, 88.6; and subjective shoulder value, 88.5%. Four complications were observed: (1) intraoperative coracoid process fracture, (2) nonunion, (3) delayed union, and (4) shoulder stiffness. The case with a coracoid process fracture during coracoid tunnel generation was converted to the K-wire tension band technique. CONCLUSION CC stabilization using a suture button device for Neer type IIB lateral clavicle fractures yielded satisfactory radiologic and clinical outcomes. The major advantage of this technique is that implant removal is not required.
Collapse
Affiliation(s)
- Chul-Hyun Cho
- Department of Orthopedic Surgery, Pain Research Center, Dongsan Medical Center, School of Medicine, Keimyung University, Daegu, Republic of Korea.
| | - Jae-Hoon Jung
- Department of Orthopedic Surgery, City Hospital, Daegu, Republic of Korea
| | - Beom-Soo Kim
- Department of Orthopedic Surgery, Pain Research Center, Dongsan Medical Center, School of Medicine, Keimyung University, Daegu, Republic of Korea
| |
Collapse
|
23
|
Menge TJ, Tahal DS, Katthagen JC, Millett PJ. Arthroscopic Acromioclavicular Joint Reconstruction Using Knotless Coracoclavicular Fixation and Soft-Tissue Anatomic Coracoclavicular Ligament Reconstruction. Arthrosc Tech 2017; 6:e37-e42. [PMID: 28373938 PMCID: PMC5368056 DOI: 10.1016/j.eats.2016.08.035] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 08/29/2016] [Indexed: 02/03/2023] Open
Abstract
Acromioclavicular joint injuries are one of the most common shoulder injuries, and there are a variety of treatment options. Recently, there have been newer arthroscopic techniques that have addressed coracoid and clavicle fracture risk by using a knotted suture-button fixation through a single, small bone tunnel with additional looped soft-tissue graft stabilization. Although clinical outcomes have been good to excellent, there have still been instances of knot and hardware irritation. The described technique builds on the latest advances and achieves an anatomic coracoclavicular (CC) reconstruction through a single knotless CC fixation device with additional soft-tissue allograft reconstruction of the CC ligaments. This technique minimizes the risks of coracoid and clavicle fractures and knot and hardware irritation while maintaining excellent stability.
Collapse
Affiliation(s)
- Travis J Menge
- Steadman Philippon Research Institute, Vail, Colorado, U.S.A.; The Steadman Clinic, Vail, Colorado, U.S.A
| | - Dimitri S Tahal
- Steadman Philippon Research Institute, Vail, Colorado, U.S.A
| | | | - Peter J Millett
- Steadman Philippon Research Institute, Vail, Colorado, U.S.A.; The Steadman Clinic, Vail, Colorado, U.S.A
| |
Collapse
|