1
|
Sun K, Wu Y, Wu L, Shen B. Comparison of clinical outcomes among total knee arthroplasties using posterior-stabilized, cruciate-retaining, bi-cruciate substituting, bi-cruciate retaining designs: a systematic review and network meta-analysis. Chin Med J (Engl) 2023; 136:1817-1831. [PMID: 37365688 PMCID: PMC10406014 DOI: 10.1097/cm9.0000000000002183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Indexed: 06/28/2023] Open
Abstract
BACKGROUND Despite the advent of innovative knee prosthesis design, a consistent first-option knee implant design in total knee arthroplasty (TKA) remained unsettled. This study aimed to compare the clinical effects among posterior-stabilized (PS), cruciate-retaining (CR), bi-cruciate substituting (BCS), and bi-cruciate retaining designs for primary TKA. METHODS Electronic databases were systematically searched to identify eligible randomized controlled trials (RCTs) and cohort studies from inception up to July 30, 2021. The primary outcomes were the range of knee motion (ROM), and the secondary outcomes were the patient-reported outcome measures (PROMs) and complication and revision rates. Confidence in evidence was assessed using Confidence in Network Meta-Analysis. The Bayesian network meta-analysis was performed for synthesis. RESULTS A total of 15 RCTs and 18 cohort studies involving 3520 knees were included. The heterogeneity and inconsistency were acceptable. There was a significant difference in ROM at the early follow-up when PS was compared with CR (mean difference [MD] = 3.17, 95% confidence interval [CI] 0.07, 7.18) and BCS was compared with CR (MD = 9.69, 95% CI 2.18, 17.51). But at the long-term follow-up, there was no significant difference in ROM in any one knee implant compared with the others. No significant increase was found in the PROMs and complication and revision rates at the final follow-up time. CONCLUSIONS At early follow-up after TKA, PS and BCS knee implants significantly outperform the CR knee implant in ROM. But in the long run, the available evidence suggests different knee prostheses could make no difference in clinical outcomes after TKA with extended follow-up.
Collapse
Affiliation(s)
- Kaibo Sun
- Department of Orthopedics Surgery, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | | | | | | |
Collapse
|
2
|
Yang K, Sohn G, Sambandam S. Cruciate-Retaining Total Knee Arthroplasty: Current Concepts Review. Cureus 2023; 15:e43813. [PMID: 37746387 PMCID: PMC10511824 DOI: 10.7759/cureus.43813] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/20/2023] [Indexed: 09/26/2023] Open
Abstract
Posterior cruciate-retaining (CR) total knee arthroplasty for osteoarthritis of the knee is a popular implant choice. At present, there is no consensus on whether sacrifice or retention of the posterior cruciate ligament (PCL) offers superior outcomes. This review explores the current literature available on CR total knee arthroplasty (TKA). PubMed was searched by keyword to find relevant articles for inclusion. Additional sources came from article references and joint registry reports. CR design knees have distinct kinematic gait patterns from posterior-stabilizing (PS) knees and exhibit paradoxical anterior femoral movement with less femoral rollback. While CR implants offer less flexion than PS designs, the difference is not clinically detectable as clinical scores are similar in the short and long term. CR implants have better long-term survival compared to PS knees, likely due to lower risk of aseptic loosening. CR total knee arthroplasties also have shorter operating times and lower risk of peri-prosthetic fractures. Because the CR implant is unconstrained, there may be an increased risk of instability compared to PS designs, but the literature is mixed. Overall, the current literature supports the continued use of CR TKAs due to their lower risk of complications, durability, and demonstrated equivalence in function to posterior-substituting models.
Collapse
Affiliation(s)
- Kristine Yang
- Orthopedics, University of Texas Southwestern Medical Center, Dallas, USA
| | - Garrett Sohn
- Orthopedics, University of Texas Southwestern Medical Center, Dallas, USA
| | - Senthil Sambandam
- Orthopedics, University of Texas Southwestern Medical Center, Dallas, USA
| |
Collapse
|
3
|
Does contemporary bicruciate retaining total knee arthroplasty restore the native knee kinematics? A descriptive literature review. Arch Orthop Trauma Surg 2022; 142:2313-2322. [PMID: 34406507 DOI: 10.1007/s00402-021-04116-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 07/28/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND There has been no consensus on the benefit of retaining the anterior cruciate ligament (ACL) in TKAs. This study aims to review recent evidences around the kinematics of bicruciate retaining (BCR) total knee arthroplasty (TKA). MATERIALS AND METHODS A search of the literature was conducted on PubMed and Web of Science. Reports that assessed the BCR TKA kinematics, including both in vitro cadaveric studies and in vivo clinical studies, were reviewed. RESULTS A total number of 169 entries were obtained. By exclusion criteria, five in vitro studies using cadaveric knee specimens and six in vivo studies using patient cohorts were retained. In vitro studies showed a low internal rotation (< 10°) throughout the flexion path in all BCR TKAs. Compared to native knees, the difference in the internal rotation was maximal during early and late flexion; the femur in the BCR TKA was significantly more anteriorly positioned (1.7-3.6 mm from 0° to 110°) and more externally rotated (3.6°-4.2° at 110° and 120°). In vivo studies revealed that the native knee kinematics, in general, were not fully restored after BCR TKA during various knee activates (squatting, level-walking, and downhill-walking). There are asymmetric kinematics during the stance phase of gait cycle and a smaller range of axial rotation (23% patients exhibiting external tibial rotation) throughout the gait cycle in BCR TKAs. CONCLUSIONS Critical insights in the complex BCR TKA biomechanics have been reported from recent laboratory kinematics studies. However, whether contemporary BCR TKAs can fully restore native knee kinematics remains debatable, warranting further investigations.
Collapse
|
4
|
Lau LCM, Ong MTY, Chau WW, Ng JP, Griffith JF, Ho KKW. Avulsion Fracture of Bicruciate Ligament and Patellar Tendon in Bicruciate-Retaining Total Knee Arthroplasty. Arthroplast Today 2022; 16:57-62. [PMID: 35662997 PMCID: PMC9156988 DOI: 10.1016/j.artd.2022.04.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 04/26/2022] [Accepted: 04/26/2022] [Indexed: 12/29/2022] Open
Abstract
Tibial intercondylar fracture with anterior cruciate ligament avulsion is a unique but rare complication of bicruciate-retaining total knee arthroplasty. Here, we describe an even rarer condition that the tibial intercondylar fracture involved bicruciate ligament and partial patellar tendon avulsion fracture resulting in significant clinical instability in a 70-year-old woman, a combination not yet reported in the literature. Dual-energy computed tomography helped characterize the fracture. During revision surgery, the bicruciate retaining total knee arthroplasty was revised to posterior-stabilized total knee arthroplasty and the patellar tendon was repaired with a suture anchor. She recovered well progressively, and at 6 months, she could walk with the use of an assisted walking device.
Collapse
|
5
|
Eggenberger EE, Hurst JM, Morris MJ, Berend KR, Lombardi AV, Crawford DA. Midterm Outcomes of a Bicruciate-Retaining Compared With the Bicruciate-Sacrificing Knee System. J Arthroplasty 2022; 37:S245-S249. [PMID: 35190243 DOI: 10.1016/j.arth.2021.12.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/03/2021] [Accepted: 12/09/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The purpose of this study is to report midterm outcomes and survivorship of a bicruciate retaining knee arthroplasty compared with a bicruciate sacrificing anterior stabilized knee arthroplasty. METHODS A retrospective comparative cohort analysis was performed of all patients who underwent primary total knee arthroplasty with the bicruciate retaining (XP) knee arthroplasty compared with an anterior stabilized (AS) cruciate sacrificing bearing. The XP system was used in 195 knees and was compared with 1471 knees in which the AS bearing was used. Patients were included in analysis if they had minimum 2-year follow-up or had a revision at any point. Preoperative and postoperative range of motion, Knee Society Scores, complications, and reoperations were evaluated. Unpaired t-test and chi-square analysis were performed. Kaplan-Meier survival analysis was performed for all-cause and aseptic survival. RESULTS At an average of 5.2-year follow-up, 22 (11.3%) XP knees had been revised, compared with 23 (1.6%) AS knees (P < .001). Nineteen (9.7%) XP knees were revised for aseptic tibial loosening; one (0.1%) of the AS knees was revised for the same (P < .001). Nineteen of the XR revision surgeries (86.4%) were for aseptic tibial loosening. Compared with AS knees, the XP knees had significantly lower improvement in range of motion (3.2 deg vs 2.2 deg, P < .001), Knee Society (KS) pain scores (39 vs 35.7, P = .014), KS clinical scores (52.4 vs 46, P < .001), and KS functional scores (20.9 vs 15.5, P = .01). CONCLUSION The bicruciate retaining Vanguard XP Total Knee System demonstrated an unacceptably high rate of aseptic tibial loosening without conferring the benefit of improved postoperative function relative to other available bearings.
Collapse
Affiliation(s)
| | - Jason M Hurst
- Joint Implant Surgeons, Inc, New Albany, OH; Mount Carmel Health System, New Albany, OH
| | - Michael J Morris
- Joint Implant Surgeons, Inc, New Albany, OH; Mount Carmel Health System, New Albany, OH
| | - Keith R Berend
- Joint Implant Surgeons, Inc, New Albany, OH; Mount Carmel Health System, New Albany, OH
| | - Adolph V Lombardi
- Joint Implant Surgeons, Inc, New Albany, OH; Mount Carmel Health System, New Albany, OH
| | - David A Crawford
- Joint Implant Surgeons, Inc, New Albany, OH; Mount Carmel Health System, New Albany, OH
| |
Collapse
|
6
|
Itoh M, Itou J, Kuwashima U, Okazaki K. Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study. BMC Musculoskelet Disord 2022; 23:14. [PMID: 34980073 PMCID: PMC8725250 DOI: 10.1186/s12891-021-04971-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 12/20/2021] [Indexed: 01/01/2023] Open
Abstract
Background Knee replacement is a very effective and indispensable treatment option for end-stage knee arthritis, and the number of cases has been increasing worldwide. A replaced knee joint without patient joint awareness is thought to be the ultimate goal of artificial knees. Joint awareness reportedly correlates with patient satisfaction. Although numbness around a replaced knee is a minor but common problem, its effect on postoperative outcome is controversial. Joint awareness also is sensitive to subtle abnormalities of the joint, so it must be negatively affected by numbness. Although numbness is minor, it cannot be ignored to further improve knee replacement outcomes. This study investigated the relationship between patient-reported numbness and other patient-reported outcome measures (PROMs), including joint awareness, and kneeling. We developed a numbness score based on a 5-point Likert scale on frequency of numbness, with an intraclass correlation coefficient of 0.76 and higher scores indicating less numbness. Methods The numbness score, New Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score-12 (FJS-12), and other clinical and radiological data from 311 patients (394 primary knee replacements) were analyzed. Kneeling ability was evaluated by using kneeling-specific items in the KSS (KSS-Kneeling). Results No numbness was found in 170 knees (43.1%), and some degree of numbness was found in the remaining 224 knees (56.9%). The numbness score showed weak-to-moderate correlations with KSS-Symptoms (r = 0.44), KSS-Satisfaction (r = 0.41), KSS-Activities (r = 0.29), and all KOOS subscales (r = 0.23–0.44), and FJS-12 (r = 0.42). Multiple regression analyses suggested that midline incision positively affected the numbness score over the anteromedial incision (p = 0.04) and that a better numbness score (p = 0.001), male sex (p < 0.0001), and better postoperative knee flexion angle (0.04) positively affected kneeling. Conclusions The numbness score positively correlated with PROMs and positively affected kneeling. Knee replacements performed via an anteromedial incision may be at higher risk for numbness. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04971-6.
Collapse
Affiliation(s)
- Masafumi Itoh
- Department of Orthopaedic surgery, Tokyo Women's Medical University, 8-1, Kawada-Cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Junya Itou
- Department of Orthopaedic surgery, Tokyo Women's Medical University, 8-1, Kawada-Cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Umito Kuwashima
- Department of Orthopaedic surgery, Tokyo Women's Medical University, 8-1, Kawada-Cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Ken Okazaki
- Department of Orthopaedic surgery, Tokyo Women's Medical University, 8-1, Kawada-Cho, Shinjuku-ku, Tokyo, 162-8666, Japan.
| |
Collapse
|
7
|
Itoh M, Itou J, Kuwashima U, Okazaki K. Good Validity and High Internal Consistency of the Forgotten Joint Score-12 in Patients After Medial Opening Wedge High Tibial Osteotomy. J Arthroplasty 2021; 36:2691-2697. [PMID: 33812712 DOI: 10.1016/j.arth.2021.03.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 03/04/2021] [Accepted: 03/08/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The Forgotten Joint Score-12 (FJS-12) was originally developed to assess awareness of an artificial joint. Medial opening wedge high tibial osteotomy (MOWHTO), an alternative surgical method of knee replacement, is a joint-preservation surgery; therefore, joint awareness should be used to evaluate its clinical results. However, FJS-12 has not been validated as a tool to evaluate the postoperative results of MOWHTO. This study aimed to validate FJS-12 in MOWHTO. METHODS Patients with bilateral knee surgery, previous knee surgery, flexion contracture >15°, varus alignment >20°, and patients without plate removal surgery were excluded. Finally, 71 knees of 71 patients were analyzed, with a mean follow-up of 34.5 months. The FJS-12 score and Knee Injury and Osteoarthritis Outcome Score (KOOS) were obtained, and the floor and ceiling effect of each score was investigated. Cronbach's α was calculated to determine the internal consistency of FJS-12. Spearman's correlation coefficients between FJS-12 and KOOS were calculated to assess convergent validity. RESULTS There were ceiling effects in 3 KOOS subscales (symptoms [25.4%], pain [15.5%], and activities of daily living [25.4%]) but not in FJS-12 (8.5%). No floor effect was noted in any patient-reported outcome measures. The total Cronbach's α was 0.9457 in FJS-12. FJS-12 showed moderate-to-strong positive correlations with all KOOS subscales (r = 0.64-0.72). CONCLUSION FJS-12 showed a lower ceiling effect than KOOS and high internal consistency and convergent validity in patients following MOWHTO. With its low ceiling effect, FJS-12 was found to be useful for evaluating patients following MOWHTO.
Collapse
Affiliation(s)
- Masafumi Itoh
- Department of Orthopedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
| | - Junya Itou
- Department of Orthopedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
| | - Umito Kuwashima
- Department of Orthopedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
| | - Ken Okazaki
- Department of Orthopedic Surgery, Tokyo Women's Medical University, Tokyo, Japan
| |
Collapse
|
8
|
Zhang Q, Chen Z, Jin Z, Muratoglu OK, Varadarajan KM. Patient-specific musculoskeletal models as a framework for comparing ACL function in unicompartmental versus bicruciate retaining arthroplasty. Proc Inst Mech Eng H 2021; 235:861-872. [PMID: 33913346 DOI: 10.1177/09544119211011827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Unicompartmental knee arthroplasty has been shown to provide superior functional outcomes compared to total knee arthroplasty and have motivated development of advanced implant designs including bicruciate retaining knee arthroplasty. However, few validated frameworks are available to directly compare the effect of implant design and surgical techniques on ligament function and joint kinematics. In the present study, the subject-specific lower extremity models were developed based on musculoskeletal modeling framework using force-dependent kinematics method, and validated against in vivo telemetric data. The experiment data of two subjects who underwent TKA were obtained from the SimTK "Grand Challenge Competition" repository, and integrated into the subject-specific lower extremity model. Five walking gait trials and three different knee implant models for each subject were used as partial inputs for the model to predict knee biomechanics for unicompartmental, bicruciate retaining, and total knee arthroplasty. The results showed no significant differences in the tibiofemoral contact forces or angular kinematic parameters between three groups. However, unicompartmental knee arthroplasty demonstrated significantly more posterior tibial location between 0% and 40% of the gait cycle (p < 0.017). Significant differences in range of tibiofemoral anterior/posterior translation and medial/lateral translation were also observed between unicompartmental and bicruciate retaining arthroplasty (p < 0.017). Peak values of anterior cruciate ligament forces differed between unicompartmental and bicruciate retaining arthroplasty from 10% to 30% of the gait cycle. Findings of this study indicate that unicompartmental and bicruciate retaining arthroplasty do not have identical biomechanics and point to the complementary role of anterior cruciate ligament and articular geometry in guiding knee function. Further, the patient-specific musculoskeletal model developed provides a reliable framework for assessing new implant designs, and effect of surgical techniques on knee biomechanics following arthroplasty.
Collapse
Affiliation(s)
- Qida Zhang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China.,Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Zhenxian Chen
- Key Laboratory of Road Construction Technology and Equipment (Ministry of Education), School of Mechanical Engineering, Chang'an University, Xi'an, China
| | - Zhongmin Jin
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China.,Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China.,Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Orhun K Muratoglu
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Kartik M Varadarajan
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
9
|
Freigang V, Weber J, Mueller K, Pfeifer C, Worlicek M, Alt V, Baumann FM. Evaluation of joint awareness after acetabular fracture: Validation of the Forgotten Joint Score according to the COSMIN checklist protocol. World J Orthop 2021; 12:69-81. [PMID: 33614426 PMCID: PMC7866484 DOI: 10.5312/wjo.v12.i2.69] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 12/14/2020] [Accepted: 01/22/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND A fracture of the acetabulum is an uncommon, but serious injury. Established outcome tools do not reflect the patient’s perspective after fracture of the hip joint. Originally designed for post-arthroplasty patients, the Forgotten Joint Score (FJS) is a patient-reported outcome measurement (PROM) tool evaluating the disease-specific health-related quality of life (HR-QoL).
AIM To validate the FJS in patients after acetabular fracture.
METHODS In a prospective mono-centric cohort study, we evaluated 100 patients at mean 5.2 ± 3.6 years after a fracture of the acetabulum. The validation study followed the complete COSMIN checklist protocol. For calculation of convergent validity, we used the Tegner-Activity Scale, the Western Ontario and McMaster Universities Osteoarthritis Index, the EuroQol-5D, and a subjective rating of change as an anchor variable.
RESULTS We confirmed good internal consistency with a Cronbach‘s alpha of 0.95. With an intraclass correlation coefficient of 0.99 (95%CI: 0.97, 0.99), test-retest reliability of the FJS was excellent. Correlation coefficients between the questionnaires were moderate to high ranging from |0.56| to |0.83| (absolute value). No relevant floor or ceiling effects occurred. Standard error of measurement was 3.2 and smallest detectable change (SDC) was 8.8. Thus, changes greater than 8.8 points between two assessments denote a real change in FJS.
CONCLUSION The FJS is a valid and reliable tool for evaluation of patient-reported outcome in posttraumatic condition after acetabular fracture. The SDC indicating a real clinical improvement was 8.8 points in the FJS. We could confirm responsiveness of the FJS and found no relevant floor- or ceiling effects.
Collapse
Affiliation(s)
- Viola Freigang
- Department of Trauma Surgery, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Johannes Weber
- Department of Trauma Surgery, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Karolina Mueller
- Center for Clinical Studies, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Christian Pfeifer
- Department of Trauma Surgery, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Michael Worlicek
- Department of Trauma Surgery, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Volker Alt
- Department of Trauma Surgery, Regensburg University Medical Center, Regensburg 93042, Germany
| | - Florian Michael Baumann
- Department of Trauma Surgery, Regensburg University Medical Center, Regensburg 93042, Germany
| |
Collapse
|
10
|
Bi-cruciate retaining total knee arthroplasty: a systematic literature review of clinical outcomes. Arch Orthop Trauma Surg 2021; 141:293-304. [PMID: 33047230 DOI: 10.1007/s00402-020-03622-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 09/30/2020] [Indexed: 12/21/2022]
Abstract
Total knee arthroplasty (TKA) has been shown to have good long-term outcomes and survivorship. Nonetheless, dissatisfied patients are frequently reported in the literature. Bi-cruciate retaining total knee prostheses (BCR TKA) were designed to address the demand for more kinematically functional implants that better reconstruct natural knee kinematics. In BCR TKA, the anterior cruciate ligament (ACL) is preserved. Improved patient-reported outcomes and satisfaction levels are expected. This review aimed to summarize indications for and clinical outcomes of BCR TKA. A systematic literature review on BCR TKA was performed. 24 articles were included for data analysis. Indications covered osteoarthritis, inflammatory arthritis and others. The degree of deformity was often but not always limited to minor axial deformity and contractures: maximum acceptable varus/valgus deformity reached 10°-30° and flexion contractures of 15°-65°. ACL intactness was macroscopically examined intraoperatively in nine studies and clinically tested in ten studies (e.g., Lachmann Test, drawer-test). Objective and patient-reported outcome scores were reported for follow-up periods of up to 22 years. Survival rates varied significantly. For first generation implants, 22-year survival reached 82% while a second generation design was associated with 13.5% revision rate at 18 months. Reasons for varying outcomes were not clear and may be attributed to the implant itself, surgical techniques and patient specific variables including changed expectations and functional demand. The literature has not shown clear indications and guidelines for the use of BCR implants. The promising results of first generation BCR TKA designs may be optimized through improved implant designs in the future. Further studies are advocated to provide the necessary evidence of second generation BCR TKA designs.
Collapse
|
11
|
Takasago T, Hamada D, Wada K, Nitta A, Tamaki Y, Goto T, Tsuruo Y, Sairyo K. Insufficient lateral joint laxity after bicruciate-retaining total knee arthroplasty potentially influences kinematics during flexion: A biomechanical cadaveric study. Knee 2021; 28:311-318. [PMID: 33477002 DOI: 10.1016/j.knee.2020.12.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 11/10/2020] [Accepted: 12/21/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND Soft tissue balancing in bicruciate-retaining (BCR) total knee arthroplasty (TKA) is a challenge that must be overcome to achieve excellent clinical outcomes. However, the optimal degree of joint laxity has yet to be clarified. This cadaveric study sought to examine joint laxity after BCR TKA using a navigation system. METHODS Knee joint laxity was quantified using an image-free navigation system in 8 intact fresh frozen cadavers under three conditions: the native knee, BCR TKA knee, and BCR TKA knee after anterior cruciate ligament resection. Rotational kinematics in the BCR TKA knee during flexion were compared according to whether joint laxity was increased or decreased. RESULTS Knee joint laxity after BCR TKA under varus-valgus movement, anterior translation, and internal-external rotation loadings was similar to that of the native knee. However, lateral joint laxity was decreased during flexion in some cases. BCR TKA-treated knees with decreased lateral joint laxity at 90° of flexion demonstrated more limited tibial internal rotation in deep flexion than the native knee (p < 0.05). The loss of internal rotation in deep flexion was partly recovered by using a lateral insert with a posterior slope of +3°. CONCLUSIONS Restoring optimal joint laxity was not always straightforward in BCR TKA if the 4 ligaments were preserved. Lateral joint laxity was potentially decreased in BCR TKA and may result in kinematic conflict during flexion. Surgeons should be aware of the need to achieve sufficient lateral joint laxity in this type of BCR TKA.
Collapse
Affiliation(s)
- Tomoya Takasago
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| | - Daisuke Hamada
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| | - Keizo Wada
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| | - Akihiro Nitta
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan
| | - Yasuaki Tamaki
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| | - Tomohiro Goto
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| | - Yoshihiro Tsuruo
- Department of Anatomy, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| | - Koichi Sairyo
- Department of Orthopedics, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto, Tokushima 770-8503, Japan.
| |
Collapse
|
12
|
Freigang V, Rupp M, Pfeifer C, Worlicek M, Radke S, Deckelmann S, Alt V, Baumann F. Patient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis. BMC Musculoskelet Disord 2020; 21:773. [PMID: 33234122 PMCID: PMC7686700 DOI: 10.1186/s12891-020-03776-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 11/05/2020] [Indexed: 12/02/2022] Open
Abstract
Background Unicondylar knee arthroplasty was introduced in the late 1960s and remains a topic of controversial discussion. Patient-specific instruments and patient-specific implants are not yet the standard of care. The question remains whether this time-consuming and costly technique can be beneficial for the patient. The aim of this study was to evaluate whether a custom-made unicondylar knee arthroplasty leads to improved patient-reported outcome. Methods This retrospective study evaluates the patient-reported outcome after custom-made unicondylar knee arthroplasty (CM-UKA, ConforMIS™ iUni® G2, ConforMIS Inc., Billerica, MA, USA). We evaluated 29 patients (31 knees) at an average of 2.4 years (range 1.2–3.6 years) after operation for unicondylar osteoarthritis of the knee. The target zone for the postoperative leg axis was a slight under-correction of 0–2° varus. Follow-up evaluation included the Forgotten Joint Score (FJS), the Knee Society Score (KSS), a Visual Analogue Scale (VAS) and a radiographic evaluation including a long-leg radiograph. Primary outcome measure was patient satisfaction based on the Forgotten Joint Score. Results We found an excellent postoperative health-related quality of life with a mean FJS of 76.8 (SD 17.9) indicating a low level of joint awareness after CM-UKA. The mean preoperative KSS was 66.0 (SD 13.71) and 59.4 (17.9) for the KSS function score. The increase was 22.8 points for the KSS knee score (p < 0.0001) and 34.8 points for the KSS function score (p < 0.0001). The VAS for pain decreased from a mean of 5.4 (SD 1.8) to 1.1 (SD 1.2) (p < 0.0001). The malalignment rate with a postoperative deviation of more than 2° in the leg axis was 29%. There was no evidence of component loosening after a mean follow-up of 2.4 years. Conclusions Custom-made unicondylar knee arthroplasty (CM-UKA) can provide improved clinical and functional outcomes for patients with isolated knee osteoarthritis of the medial compartment. We found excellent results regarding patient satisfaction and a low malalignment rate for CM-UKA. Further studies are needed to investigate long-term survivorship of the implant. Level of evidence Level IV. Trial registration Trial Registration number: Z-2014-0389-10 Regensburg Clinical Studies Center (REGCSC) 09/07/2014.
Collapse
Affiliation(s)
- Viola Freigang
- Department of Trauma Surgery, Regensburg University Medical Center, 93042, Regensburg, Germany
| | - Markus Rupp
- Department of Trauma Surgery, Regensburg University Medical Center, 93042, Regensburg, Germany
| | - Christian Pfeifer
- Department of Trauma Surgery, Regensburg University Medical Center, 93042, Regensburg, Germany
| | - Michael Worlicek
- Department of Trauma Surgery, Regensburg University Medical Center, 93042, Regensburg, Germany
| | - Stefan Radke
- Department of Orthopaedic Surgery, Rotkreuzklinikum Munich, Munich, Germany
| | - Stephan Deckelmann
- Department of Orthopaedic Surgery, Rotkreuzklinikum Munich, Munich, Germany
| | - Volker Alt
- Department of Trauma Surgery, Regensburg University Medical Center, 93042, Regensburg, Germany
| | - Florian Baumann
- Department of Trauma Surgery, Regensburg University Medical Center, 93042, Regensburg, Germany.
| |
Collapse
|
13
|
Kosse NM, Heesterbeek PJC, Defoort KC, Wymenga AB, van Hellemondt GG. Maximal flexion and patient outcomes after TKA, using a bicruciate-stabilizing design. Arch Orthop Trauma Surg 2020; 140:1495-1501. [PMID: 32468168 DOI: 10.1007/s00402-020-03491-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Indexed: 10/24/2022]
Abstract
INTRODUCTION Physiological motion after total knee arthroplasty (TKA) should result in a large range of motion, which would lead to good clinical outcomes. An adjusted design of a bicruciate-stabilizing TKA was developed to reproduce physiological motion. The aim of this study was to (1) investigate the maximal knee flexion of this knee system, 1 year post-operatively; (2) determine the clinical and functional improvement and compare the outcomes between patients with and without high maximal flexion; and (3) evaluate the adverse events. MATERIALS AND METHODS In this prospective study, 62 patients with osteoarthritis received a bicruciate-stabilizing TKA. Maximum flexion was measured on a lateral X-ray pre- and post-operatively. Clinical and functional scores and the adverse events were reported up until 2 years after surgery. RESULTS Pre-operatively, the median (range) maximal flexion was 131.5 (90-153)° and 1 year post-operatively, it was 130 (82-150)°. The results for the clinical scores showed an improvement between pre-operative values and post-operative values. The Kujala score and Knee Osteoarthritis Outcome Score (KOOS) symptoms, sport and quality of life score were better in patients with high maximal flexion (≥ 125°). Ten (serious) adverse device events were reported. CONCLUSIONS In conclusion, the bicruciate-stabilizing TKA obtained a maximal flexion comparable to the flexion pre-operatively and resulted in good clinical and functional outcomes. Patients with high flexion ability seem to perform better on clinical and functional outcomes. Furthermore, the adjusted design of the bicruciate-stabilizing TKA reduced the number of adverse events. LEVEL OF EVIDENCE Prospective cohort study, Level II.
Collapse
Affiliation(s)
- Nienke M Kosse
- Sint Maartenskliniek Research, Sint Maartenskliniek, P.O. box 9011, 6500 GM, Nijmegen, The Netherlands.
| | - Petra J C Heesterbeek
- Sint Maartenskliniek Research, Sint Maartenskliniek, P.O. box 9011, 6500 GM, Nijmegen, The Netherlands.
| | - Koen C Defoort
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Ate B Wymenga
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, The Netherlands
| | | |
Collapse
|
14
|
Zhang Q, Chen Z, Zhang Z, Jin Z, Muratoglu OK, Varadarajan KM. Leveraging subject-specific musculoskeletal modeling to assess effect of anterior cruciate ligament retaining total knee arthroplasty during walking gait. Proc Inst Mech Eng H 2020; 234:1445-1456. [DOI: 10.1177/0954411920947204] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Bi-cruciate retaining total knee arthroplasty has several potential advantages including improved anteroposterior knee stability compared to contemporary posterior cruciate-retaining total knee arthroplasty. However, few studies have explored whether there is significant differences of knee biomechanics following bi-cruciate retaining total knee arthroplasty compared to posterior cruciate-retaining total knee arthroplasty. In the present study, subject-specific lower extremity musculoskeletal multi-body dynamics models for bi-cruciate retaining, bi-cruciate retaining without anterior cruciate ligament, and posterior cruciate-retaining total knee arthroplasty were developed based on the musculoskeletal modeling framework using force-dependent kinematics method and validated against in vivo telemetric data. The experiment data of two subjects who underwent total knee arthroplasty were obtained for the SimTK “Grand Challenge Competition” repository, and integrated into the musculoskeletal model. Five walking gait trials for each subject were used as partial inputs for the model to predict the knee biomechanics for bi-cruciate retaining, bi-cruciate retaining without anterior cruciate ligament, and posterior cruciate-retaining total knee arthroplasty. The results revealed significantly greater range of anterior/posterior tibiofemoral translation, and significantly more posterior tibial location during the early phase of gait and more anterior tibial location during the late phase of gait were found in bi-cruciate retaining total knee arthroplasty without anterior cruciate ligament when compared to the bi-cruciate retaining total knee arthroplasty. No significant differences in tibiofemoral contact forces, rotations, translations, and ligament forces between bi-cruciate retaining and posterior cruciate-retaining total knee arthroplasty during normal walking gait, albeit slight differences in range of tibiofemoral internal/external rotation and anterior/posterior translation were observed. The present study revealed that anterior cruciate ligament retention has a positive effect on restoring normal knee kinematics in bi-cruciate retaining total knee arthroplasty. Preservation of anterior cruciate ligament in total knee arthroplasty and knee implant designs interplay each other and both contribute to restoring normal knee kinematics in different types of total knee arthroplasty. Further evaluation of more demanding activities and subject data from patients with bi-cruciate retaining and posterior cruciate-retaining total knee arthroplasty via musculoskeletal modeling may better highlight the role of the anterior cruciate ligament and its stabilizing influence.
Collapse
Affiliation(s)
- Qida Zhang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Zhenxian Chen
- Key Laboratory of Road Construction Technology and Equipment (Ministry of Education), School of Mechanical Engineering, Chang’an University, Xi’an, China
| | - Zhifeng Zhang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Zhongmin Jin
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Orhun K Muratoglu
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Kartik M Varadarajan
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
15
|
Kwon YM, Arauz P, Peng Y, Klemt C. In vivo kinematics of deep lunges and sit-to-stand activities in patients with bicruciate-retaining total knee arthroplasty. Bone Joint J 2020; 102-B:59-65. [PMID: 32475273 DOI: 10.1302/0301-620x.102b6.bjj-2019-1552.r2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
AIMS The removal of the cruciate ligaments in total knee arthroplasty (TKA) has been suggested as a potential contributing factor to patient dissatisfaction, due to alteration of the in vivo biomechanics of the knee. Bicruciate retaining (BCR) TKA allows the preservation of the cruciate ligaments, thus offering the potential to reproduce healthy kinematics. The aim of this study was to compare in vivo kinematics between the operated and contralateral knee in patients who have undergone TKA with a contemporary BCR design. METHODS A total of 29 patients who underwent unilateral BCR TKA were evaluated during single-leg deep lunges and sit-to-stand tests using a validated computer tomography and fluoroscopic imaging system. In vivo six-degrees of freedom (6DOF) kinematics were compared between the BCR TKA and the contralateral knee. RESULTS During single-leg deep lunge, BCR TKAs showed significantly less mean posterior femoral translation (13 mm; standard deviation (SD) 4) during terminal flexion, compared with the contralateral knee (16.6 mm, SD 3.7; p = 0.001). Similarly, BCR TKAs showed significantly less mean femoral rollback (11.6 mm (SD 4.5) vs 14.4 mm (SD 4.6); p < 0.043) during sit-to-stand. BCR TKAs showed significantly reduced internal rotation during many parts of the strenuous flexion activities particularly during high-flexion lunge (4° (SD 5.6°) vs 6.5° (SD 6.1°); p = 0.051) and during sit-to-stand (4.5° (SD 6°) vs 6.9° (SD 6.3°); p = 0.048). CONCLUSION The contemporary design of BCR TKA showed asymmetrical flexion-extension and internal-external rotation, suggesting that the kinematics are not entirely reproduced during strenuous activities. Future studies are required to establish the importance of patient factors, component orientation and design, in optimizing kinematics in patients who undergo BCR TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):59-65.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA; Associate Professor, Harvard Medical School, Boston, Massachusetts, USA
| | - Paul Arauz
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Yun Peng
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Christian Klemt
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
16
|
De Faoite D, Ries C, Foster M, Boese CK. Indications for bi-cruciate retaining total knee replacement: An international survey of 346 knee surgeons. PLoS One 2020; 15:e0234616. [PMID: 32542002 PMCID: PMC7295230 DOI: 10.1371/journal.pone.0234616] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Accepted: 05/29/2020] [Indexed: 12/18/2022] Open
Abstract
There is limited evidence on total knee arthroplasty (TKA) that retains the anterior and the posterior cruciate ligaments. Bi-cruciate retaining (BCR) TKA is considered to show improved clinical function and kinematics. This survey aimed to (1) identify interest in and acceptance of BCR TKA surgery and (2) to capture the range of indications for BCR in the opinion of practicing knee surgeons. 346 surgeons with experience in TKA surgery completed a bi-lingual online survey. Demographics, arthroplasty experience as well as acceptance of and indications for BCR TKA were collected. 53 surgeons were experienced in BCR TKA and 225 would consider implanting it. A mean of 19.5% of TKA patients were considered eligible for BCR TKA. 56.3% were thought to have intact ACL at the time of TKA surgery. Surgeons were not likely to perform BCR TKA in patients with inflammatory arthritis, aged over 80, BMI above 34.9 kg/m2, a varus or valgus deformity of more than 10° and flexion contractures of more than 10°. There is strong interest among orthopedic surgeons to perform BCR TKA and the percentage of potentially eligible patients is high. Significant joint deformity is a limitation of BCR TKA, while age and high BMI are less relevant. BCR TKA experienced surgeons are less restrictive.
Collapse
Affiliation(s)
| | - Christian Ries
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Christoph Kolja Boese
- Department of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Cologne, Germany
- Smith + Nephew GmbH, Hamburg, Germany
| |
Collapse
|
17
|
Regional differences between the US, Scandinavia, and South Korea in patient demographics and patient-reported outcomes for primary total knee arthroplasty. Arch Orthop Trauma Surg 2020; 140:93-108. [PMID: 31650229 DOI: 10.1007/s00402-019-03286-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Differences in total knee arthroplasty (TKA) patient demographics and clinical outcomes may exist between international regions, yet research is limited. The aim of this study was, therefore, to compare TKA patient demographics and patient-reported outcome measure (PROM) scores between the US, Scandinavia, and South Korea. MATERIALS AND METHODS A total of 398 TKA patients from three regions were assessed: 169 in Scandinavia (3 centers), 129 in the US (3 centers), and 100 patients in South Korea (2 centers). Regional variation in patient demographics was assessed using Kruskal-Wallis H tests. Regional variation in PROM scores from preoperative, 1-, 3- and 5-year visits was assessed using piecewise linear mixed effect models. The PROMs analyzed were a numerical rating scale for satisfaction and the Knee Osteoarthritis Outcome Score. RESULTS South Korean patients were the oldest (p < 0.001) and had the highest Charnley class (p < 0.001); US patients had the highest BMI (p < 0.001); Scandinavian patients had the lowest preoperative KL grade (p < 0.001). Scandinavian patients were associated with better preoperative and worse postoperative PROM scores. Scandinavian patients were also associated with moderately lower levels of satisfaction. These differences were lessened but remained significant after controlling for relevant demographic and surgical factors. CONCLUSIONS Regional differences were found in TKA patient demographics and PROMs between the US, Scandinavia, and South Korea. The regional differences in patient demographics support the need for more research and clear guidelines related to TKA appropriateness criteria. The better preoperative and worse postoperative Scandinavian PROM scores may have been related to their less severe KL grade but might also reflect cultural differences in how patients reflect on their health state when answering PROMs. Clinicians should be aware of these international differences in PROM scores when interpreting studies conducted in different international regions. Future studies should investigate TKA variation between more international regions and assess intraregional variation. LEVEL OF EVIDENCE Level III.
Collapse
|