1
|
Zhong Q, Pan X, Chen Y, Lian Q, Gao J, Xu Y, Wang J, Shi Z, Cheng H. Prosthetic Metals: Release, Metabolism and Toxicity. Int J Nanomedicine 2024; 19:5245-5267. [PMID: 38855732 PMCID: PMC11162637 DOI: 10.2147/ijn.s459255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 05/13/2024] [Indexed: 06/11/2024] Open
Abstract
The development of metallic joint prostheses has been ongoing for more than a century alongside advancements in hip and knee arthroplasty. Among the materials utilized, the Cobalt-Chromium-Molybdenum (Co-Cr-Mo) and Titanium-Aluminum-Vanadium (Ti-Al-V) alloys are predominant in joint prosthesis construction, predominantly due to their commendable biocompatibility, mechanical strength, and corrosion resistance. Nonetheless, over time, the physical wear, electrochemical corrosion, and inflammation induced by these alloys that occur post-implantation can cause the release of various metallic components. The released metals can then flow and metabolize in vivo, subsequently causing potential local or systemic harm. This review first details joint prosthesis development and acknowledges the release of prosthetic metals. Second, we outline the metallic concentration, biodistribution, and elimination pathways of the released prosthetic metals. Lastly, we discuss the possible organ, cellular, critical biomolecules, and significant signaling pathway toxicities and adverse effects that arise from exposure to these metals.
Collapse
Affiliation(s)
- Qiang Zhong
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Xin Pan
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Yuhang Chen
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Qiang Lian
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Jian Gao
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Yixin Xu
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Jian Wang
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Zhanjun Shi
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Hao Cheng
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| |
Collapse
|
2
|
Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements? Arch Orthop Trauma Surg 2023; 143:1217-1221. [PMID: 34724103 DOI: 10.1007/s00402-021-04206-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. MATERIAL AND METHODS Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. RESULTS Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 µg/l and 5.0 µg/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 µg/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. CONCLUSION The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.
Collapse
|
3
|
Radiographic Risk Factors Associated With Adverse Local Tissue Reaction in Head-Neck Taper Corrosion of Primary Metal-on-Polyethylene Total Hip Arthroplasty. J Am Acad Orthop Surg 2021; 29:353-360. [PMID: 32796372 DOI: 10.5435/jaaos-d-20-00473] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 07/05/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions (ALTRs) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) with head-neck taper corrosion are multifactorial, involving implant and patient factors. This study aimed to identify any potential clinical risk factors associated with failed MoP THA due to head-neck taper corrosion. METHODS A series of 146 MoP THA patients was investigated: (1) ALTR (n = 42) on metal artifact sequence MRI and (2) non-ALTR (n = 104). Both cohorts were compared regarding femoral neck shaft angle, acetabular implant orientation, component size, femoral head offset, measurement of medial and vertical femoral offsets, and femoral stem alloy. RESULTS The occurrence of ALTR was associated with increased radiographic femoral stem offset (36.0 ± 7.7 mm versus 40.8 ± 7.3 mm, P = 0.008), increased femoral head offset (0.7 ± 3.4 versus 4.5 ± 3.7, P < 0.001), and the use of Ti-12Mo-6Zr-2Fe alloy stems (P = 0.041). The presence of ALTR was notably associated with higher chromium (2.0 versus 0.5 μg/L) and cobalt (7.4 versus 0.7 μg/L, P < 0.001). DISCUSSION This study identified increased femoral head and stem offset and the use of Ti-12Mo-6Zr-2Fe alloy stems as risk factors for clinically relevant ALTR due to head-neck taper corrosion in MoP THA patients. This provides evidenced-based practical information for surgeons in identifying "at-risk" symptomatic MoP THA patients with head-neck taper corrosion for systematic risk stratification.
Collapse
|
4
|
Pietiläinen S, Mäntymäki H, Vahlberg T, Reito A, Eskelinen A, Lankinen P, Mäkelä K. Repeated cobalt and chromium ion measurements in patients with bilateral large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement. Acta Orthop 2020; 91:378-382. [PMID: 32285731 PMCID: PMC8023891 DOI: 10.1080/17453674.2020.1751940] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Whole-blood (WB) chromium (Cr) and cobalt (Co) measurements are vital in the follow-up of metal-on-metal total hip replacement (MoM THR) patients. We examined whether there is a substantial change in repeated WB, Co, and Cr levels in patients with bilateral ReCap-M2A-Magnum THR. We also specified the number of patients exceeding the safe upper limit (SUL) of WB Co and Cr in the repeated measurement.Patients and methods - We identified 141 patients with bilateral ReCap-M2A-Magnum THR operated in our institution. 61 patients had repeated WB metal ion measurements with bilateral MoM implants still in situ in the second measurement. The mean time elapsing from the first measurement (initial measurement) to the second (control measurement) was 1.9 years (SD = 0.6, range 0.2-3.5). We used earlier established SUL levels for bilateral implants by Van Der Straeten et al. (2013).Results - The median (range) Co and Cr values decreased in the repeated measurement from 2.7 (0.6-25) to 2.1 (0.5-21) and 2.6 (0.8-14) to 2.1 (0.5-18) respectively. In 13% of the patients Co levels exceeded the SUL in the initial measurement and the proportion remained constant, at 13%, in the repeated measurement. In 5% of the patients, Cr levels were above SUL in the initial measurement and an equal 5% in the control measurement.Interpretation - Repeated WB metal ion levels did not increase in patients with bilateral ReCap-M2A-Magnum THR with a mean 1.9-year measurement interval. Long-term development of WB metal ion levels is still unclear in these patients.
Collapse
Affiliation(s)
- Sakari Pietiläinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| | - Heikki Mäntymäki
- Department of Orthopaedics, Tampere University Hospital and University of Turku
| | | | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Petteri Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| |
Collapse
|
5
|
Waldstein W, Koller U, Springer B, Kolbitsch P, Brodner W, Windhager R, Lass R. Serum cobalt concentrations remain at low levels at a minimum of 20 years following metal-on-metal total hip arthroplasty. Bone Joint Res 2020; 9:146-151. [PMID: 32435467 PMCID: PMC7229295 DOI: 10.1302/2046-3758.93.bjr-2019-0218.r1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Aims Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing. Methods The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery. Results The median cobalt concentration in the MoM group was 1.04 μg/l (interquartile range (IQR) 0.64 to 1.70) at a mean of 21 years (20 to 24) postoperatively and these values were similar (p = 0.799) to cobalt levels at five years. In the CoP control group, the median cobalt levels were below the detection limit (< 0.3 μg/l; median 0.15 μg/l, IQR 0.15 to 0.75) at 20 years. The mean Harris Hip Score was 91.4 points (61 to 100) in the MoM group and 92.8 points (63 to 100) in the CoP group. Conclusion This study represents the longest follow-up series evaluating the serum cobalt levels after 28 mm head MoM bearing THA and shows that serum cobalt concentrations remain at low levels at a mean of 21 years (20 to 24) after implantation. Cite this article:Bone Joint Res. 2020;9(3):145–150.
Collapse
Affiliation(s)
- Wenzel Waldstein
- Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Ulrich Koller
- Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Bernhard Springer
- Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Paul Kolbitsch
- Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Wolfram Brodner
- Department of Orthopedics, University Hospital Krems, Krems, Austria
| | - Reinhard Windhager
- Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Richard Lass
- Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
6
|
Kim CH, Ryu JJ, Jeong MY, Kim JW, Chang JS, Yoon PW. Serum Metal Ion Levels in Cementless Metal-On-Metal Total Hip Arthroplasty: Long-Term Follow-Up Trends. J Arthroplasty 2019; 34:534-537. [PMID: 30545656 DOI: 10.1016/j.arth.2018.11.023] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Revised: 09/30/2018] [Accepted: 11/14/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Long-term trends in serum metal ion concentration after metal-on-metal (MoM) total hip arthroplasty (THA) are unclear. In most studies, serum metal ion levels increase initially and remain constant during follow-up. However, there are no previous studies that evaluate the metal ion level longitudinally at multiple intervals over the long term. Increasing metal ion levels during the long-term follow-up of patients who underwent cementless MoM THA has been seen, so this study investigated those trends. METHODS Seventy-one patients were followed for a minimum of 10 years (range, 10.0-18.6 years). All underwent unilateral THA with MoM bearings. Serum cobalt (Co) and chromium (Cr) levels were measured preoperatively and annually after surgery. Trends and differences in serum levels based on sex, mean age, body mass index, cup inclination, and implant selection were analyzed. RESULTS Within 5 years after the operation, the mean Co and Cr levels peaked postoperatively at 3-4 years (4.14 and 6.89 μg/L, respectively). Between 5 and 10 years postoperatively, the serum levels showed 2 tendencies. One group (62) showed a constant range, but a smaller group (9) showed increasing serum metal ion levels. The only factor which showed a difference between the 2 groups was body mass index (P = .030), which was lower in the increasing serum metal ion level group. CONCLUSION At a medium-term to long-term follow-up period, serum Co and Cr levels are not always constant. This should be considered when seeing patients with MoM THA, and laboratory tests may be needed for long-term follow-up.
Collapse
Affiliation(s)
- Chul-Ho Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae Jung Ryu
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Mi Yeon Jeong
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Ji Wan Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae Suk Chang
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Pil Whan Yoon
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
7
|
Abdel Karim M, Andrawis J, Bengoa F, Bracho C, Compagnoni R, Cross M, Danoff J, Della Valle CJ, Foguet P, Fraguas T, Gehrke T, Goswami K, Guerra E, Ha YC, Klaber I, Komnos G, Lachiewicz P, Lausmann C, Levine B, Leyton-Mange A, McArthur BA, Mihalič R, Neyt J, Nuñez J, Nunziato C, Parvizi J, Perka C, Reisener MJ, Rocha CH, Schweitzer D, Shivji F, Shohat N, Sierra RJ, Suleiman L, Tan TL, Vasquez J, Ward D, Wolf M, Zahar A. Hip and Knee Section, Diagnosis, Algorithm: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty 2019; 34:S339-S350. [PMID: 30348566 DOI: 10.1016/j.arth.2018.09.018] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
8
|
Hjorth MH, Mechlenburg I, Soballe K, Roemer L, Stilling M. The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations. J Orthop Translat 2018; 18:74-83. [PMID: 31508310 PMCID: PMC6718878 DOI: 10.1016/j.jot.2018.11.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 11/09/2018] [Accepted: 11/19/2018] [Indexed: 12/22/2022] Open
Abstract
Purpose Young and physically active patients have mainly received metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, the correlation between daily physical activity (PA) levels, serum-ion concentrations of chromium and cobalt and pseudotumours formation of patients who underwent MoM THA/RHA is insufficiently explored. Methods Ninety-nine patients with 134 hip articulations, 71 MoM THA/RHA and 63 MoP THA participated in a cross-sectional study at XXX University Hospital, Denmark, at mean 7.3 (range: 0.4–21.7) years after surgery. Patients' daily PA was monitored during a two-week period using a triaxial accelerometer. Metal artefact reduction sequence magnetic resonance imaging scans, estimation of serum-ion concentrations of chromium and cobalt and the Copenhagen Hip and Groin Outcome Score (HAGOS) questionnaire were completed on Day 14. Results Patients with a pseudotumour who underwent MoM THA/RHA had a higher average cadence of median 101.4 [interquartile range (IQR: 95.5–105)] steps/min than patients without a pseudotumor, median 96.7 (IQR: 92.2–103) steps/min (p = 0.02). Serum-ion concentrations of chromium and cobalt were higher in patients with a pseudotumour who underwent MoM THA/RHA, median 2.57 (IQR: 1.4–3.4) μg/L and 1.80 (IQR: 1.2–2.6) μg/L, respectively, than in patients without a pseudotumour, median 1.85 (IQR: 1.1–3.2) μg/L and 1.34 (IQR: 0.9–2.2) μg/L in MoM THA/RHA (p = 0.04 and p = 0.03). There was no statistical difference in these parameters between patients with and without a pseudotumour who underwent MoP THA. Daily PA levels of patients who underwent MoM THA/RHA were significantly correlated with serum-ion concentrations of chromium (p = 0.0002, r = 0.44) and cobalt (p = 0.005, r = 0.34), whereas no correlations were seen among patients who underwent MoP THA (p > 0.12). Conclusion The daily PA level of patients who underwent MoM THA/RHA influences the serum-ion concentrations of chromium and cobalt and the risk of pseudotumour formation. Translational potential of this article Results of this article add important knowledge on potential recommendations of prosthesis selection for patients with a high level of physical activity.
Collapse
Affiliation(s)
- Mette Holm Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Lone Roemer
- Department of Radiology, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| |
Collapse
|