1
|
Schippers P, Wunderlich F, Afghanyar Y, Buschmann V, Klonschinski T, Drees P, Eckhard L. High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up. INTERNATIONAL ORTHOPAEDICS 2024; 48:3101-3108. [PMID: 39320497 PMCID: PMC11564282 DOI: 10.1007/s00264-024-06325-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 09/12/2024] [Indexed: 09/26/2024]
Abstract
PURPOSE Despite numerous studies demonstrating promising short-term outcomes of Total Knee Arthroplasty (TKA) with Customized Individually Made (CIM) implants, there is a significant lack of data on their mid-term effectiveness. Given the increasing number of TKAs performed annually, the rising demand for CIM implants, and the associated burden of revision surgeries, understanding the mid-term performance of CIM implants is crucial. Therefore, this study aims to report on the mid-term (minimum 5 years) outcomes of TKA using a CIM implant. METHODS This retrospective cohort study included a consecutive series of 116 patients who received the ConforMIS® iTotal CR implant between 2015 and 2018. Inclusion criteria were end-stage knee osteoarthritis with coronal deformities below 10° and absence of ligamentous instability. Exclusion criteria included simultaneous bilateral TKA. Patients were followed up at a minimum of five years post-surgery. They completed a questionnaire reporting on satisfaction, pain levels using the Visual Analogue Scale (VAS), current weight, the Oxford Knee Score (OKS), and the Forgotten Joint Score for the knee (FJS-knee). Statistical analysis included descriptive statistics for demographic and clinical variables, and outcomes were reported as means with ranges. RESULTS The mean follow-up duration was 5.9 ± 0.8 years (range 5-7.4 years). 90% of patients stated they would undergo the same operation again, and 93% were either satisfied or very satisfied. The mean VAS for pain at rest was 2 ± 1.5 (range 0-6) and during exercise was 3 ± 2 (range 0-8). 58 patients (53%) managed to lose weight. The mean OKS was 41 ± 9 points (range 15-48), and the mean FJS-knee was 67 ± 23 points (range 4-100). No severe complications occurred. CONCLUSION CIM TKA using the ConforMIS® iTotal CR implant can achieve excellent results with 93% of patients being satisfied or very satisfied at mid-term follow-up of five years. Prospective, randomized, and patient-blinded trials comparing off-the-shelf (OTS) TKAs with CIM implants are necessary to evaluate whether these implants are superior or not.
Collapse
Affiliation(s)
- Philipp Schippers
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
| | - Felix Wunderlich
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Yama Afghanyar
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Victoria Buschmann
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Thomas Klonschinski
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Philipp Drees
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Lukas Eckhard
- Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
- Praxis für Gelenkchirurgie Bad Kreuznach, 55543, Bad Kreuznach, Germany
| |
Collapse
|
2
|
Vogel N, Kaelin R, Arnold MP. Custom total knee arthroplasty with personalised alignment showed better 2-year functional outcome compared to off-the-shelf arthroplasty. Knee Surg Sports Traumatol Arthrosc 2024; 32:3220-3229. [PMID: 38881354 PMCID: PMC11605013 DOI: 10.1002/ksa.12309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/27/2024] [Accepted: 05/27/2024] [Indexed: 06/18/2024]
Abstract
PURPOSE Customised individually made (CIM) total knee arthroplasty (TKA) with personalised alignment is relatively new and evidence is limited. The aim of this study was to compare patient-reported outcome measures between CIM and off-the-shelf (OTS) TKA patients in a matched-pair analysis with a 2-year follow-up. METHODS In this single-centre, prospective cohort study, propensity score matching was performed on 51 CIM and 51 OTS TKA. Data were measured at baseline, at 4 months, 1 and 2 years and included the Forgotten Joint Score (FJS-12), the High Activity Arthroplasty Score (HAAS), the Knee injury and Osteoarthritis Outcome Score (KOOS), the EQ-5D-3L, the EQ-Visual Analogue Scale, satisfaction, overall knee improvement, willingness to undergo the surgery again and the Knee Society Score. RESULTS At 2 years follow-up, the FJS-12 (77 vs. 67, p = .058), HAAS (13 vs. 11, p < .001), KOOS daily living (92 vs. 86, p = .029), KOOS sport (76 vs. 65, p = .019), KOOS quality of life (81 vs. 71, p = .028) and the EQ-5D (.95 vs. .90, p = .030) were higher for CIM TKA compared to OTS TKA. Satisfaction rate was 92% for CIM TKA and 84% for OTS TKA (p = .357). Most patients reported an improvement in the overall knee state (94% CIM and 90% OTS, p = .487) and almost all patients would undergo the surgery again (96% CIM and 98% OTS, p = .999). CONCLUSION The current study found that CIM TKA patients had better functional outcomes at 2 years. Patient satisfaction was high and not statistically significantly different from OTS TKA patients. LEVEL OF EVIDENCE Level II, prospective cohort study.
Collapse
Affiliation(s)
- Nicole Vogel
- Practice MEIN KNIE, Hirslanden Klinik BirshofMünchensteinSwitzerland
- Practice LEONARDO, Hirslanden Klinik BirshofMünchensteinSwitzerland
- Faculty of MedicineUniversity of BaselBaselSwitzerland
| | - Raphael Kaelin
- Practice LEONARDO, Hirslanden Klinik BirshofMünchensteinSwitzerland
| | - Markus P. Arnold
- Practice MEIN KNIE, Hirslanden Klinik BirshofMünchensteinSwitzerland
- Faculty of MedicineUniversity of BaselBaselSwitzerland
| |
Collapse
|
3
|
Chen DB, Wood JA, Griffiths-Jones W, Bellemans J, Haddad FS, MacDessi SJ. Considerations of morphometry and phenotypes in modern knee arthroplasty. Bone Joint J 2024; 106-B:1363-1368. [PMID: 39615528 DOI: 10.1302/0301-620x.106b12.bjj-2023-1269.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/07/2024]
Abstract
As advancements in total knee arthroplasty progress at an exciting pace, two areas are of special interest, as they directly impact implant design and surgical decision making. Knee morphometry considers the three-dimensional shape of the articulating surfaces within the knee joint, and knee phenotyping provides the ability to categorize alignment into practical groupings that can be used in both clinical and research settings. This annotation discusses the details of these concepts, and the ways in which they are helping us better understand the individual subtleties of each patient's knee.
Collapse
Affiliation(s)
| | - Jil A Wood
- Sydney Knee Specialists, Sydney, Australia
| | | | - Johan Bellemans
- University Hasselt, ZOL Hospitals Genk, ArthroClinic, Leuven, Belgium
| | - Fares S Haddad
- University College London Hospitals NHS Foundation Trust, London, UK
- The Bone & Joint Journal , London, UK
- Princess Grace Hospital, London, UK
| | - Samuel J MacDessi
- Sydney Knee Specialists, Sydney, Australia
- School of Clinical Medicine, University of NSW Medicine and Health, St George Private Hospital, Sydney, Australia
| |
Collapse
|
4
|
Alhifzi Z. Systematic review and meta-analysis of long term outcomes and innovations in Total Knee Arthroplasty: KINEMATIC, PERSONALIZED KNEE vs. CONVENTIONAL. Orthop Rev (Pavia) 2024; 16:122318. [PMID: 39219731 PMCID: PMC11364552 DOI: 10.52965/001c.122318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Accepted: 07/03/2024] [Indexed: 09/04/2024] Open
Abstract
Background Kinematic alignment is an emerging approach for total knee arthroplasty, with the aim to restore patient's individual pre-arthritic joint kinematics. In this systematic review and meta-analysis, we compared the kinematic alignment with the conventional mechanical alignment for total knee arthroplasty. Methods We searched PubMed, Web of Science, Cochrane Library, and Scopus on June 2, 2024. We screened the retrieved studies for eligibility. Then extracted the data from the included studies, and then pooled the data as mean difference (MD) or odds ratio (OR) with a 95% confidence interval using Review Manager Software (ver. 3.5). Results There was no significant difference between KA and MA in the different reported scores: combined KSS score at 6 months (P = 0.23) and 1 years (P = 0.60), KSS Patient satisfaction (P = 0.33), KSS function score (P = 0.07), Oxford score at 6 months (P = 0.45) and 2 years (P = 0.41), KOOS score (P = 0.26). Moreover, there was statistically significant difference in range of motion for flexion and extension at 1 and 2 years, incision length, the length of hospital stay, or the duration of surgery. Conclusion Although kinematic alignment showed slightly better clinical outcomes than mechanical alignment, the difference between the two techniques is not statistically significant.
Collapse
Affiliation(s)
- Zaki Alhifzi
- King Faisal medical city Department of Orthopedics
| |
Collapse
|
5
|
Zheng H, Chen M, Yang D, Shao H, Zhou Y. Robotic-assisted differential total knee arthroplasty with patient-specific implants: surgical techniques and preliminary results. ARTHROPLASTY 2024; 6:34. [PMID: 38853256 PMCID: PMC11163793 DOI: 10.1186/s42836-024-00255-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 04/09/2024] [Indexed: 06/11/2024] Open
Abstract
OBJECTIVE In total knee arthroplasty (TKA), achieving soft-tissue balance while retaining acceptable lower limb alignment is sometimes difficult and may lead to patient dissatisfaction. Theoretically, patient-specific implants can bring great benefits, while the lack of precise surgical tools may hinder the improvement of outcomes. The objective of this study was to illustrate surgical techniques and evaluate kinematics and early clinical outcomes of robotic-assisted TKA using patient-specific implants. METHODS Based on preoperative CT scan, femoral and tibial components were 3D printed. Medial and lateral tibial liners were separate with different thicknesses, posterior slopes and conformity. TiRobot Recon Robot was used for surgery, and was armed with smart tools that quantify gap, force and femoral-tibial track. We collected data on demographics, intraoperative gap balance and femoral-tibial motion. In the follow-up, we evaluated the range of motion, Visual Analogue Scale (VAS), forgotten joint score (FJS), Knee injury and Osteoarthritis Outcome Score, Joint Replacement (KOOS, JR) score. Radiological data were also harvested. RESULTS Fifteen patients (17 knees) were enrolled with a mean age of 64.6 ± 6.4 (53-76) years. In 5 knees, we used symmetric tibial liners, the rest were asymmetric. After surgery, the average alignment was 1.6 ± 2.0 (-3-5) degrees varus. The average follow-up lasted 6.7 ± 4.2 (1-14) months. The mean visual analogue scale was 0.8 ± 0.7 (0-2), FJS was 62.4 ± 25.3 (0-87), KOOS was 86.5 ± 9.4 (57-97). 11 patients were "very satisfied", 3 were "satisfied" with the result, and one patient was neutral due to restricted extension and unsatisfactory rehabilitation at five months' follow-up. CONCLUSIONS With patient-specific implants and robotics, TKA could be performed by a mathematical way, which was dubbed a "differential" TKA. Intraoperative kinematics was excellent in terms of gap-force balancing and femoral-tibial relative motion. Preliminary clinical outcomes were overall satisfactory.
Collapse
Affiliation(s)
- Hanlong Zheng
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, No. 31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China
| | - Mingxue Chen
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, No. 31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China
| | - Dejin Yang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, No. 31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China
| | - Hongyi Shao
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, No. 31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China
| | - Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, No. 31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
| |
Collapse
|
6
|
Le Stum M, Clave A, Adzinyo Agbemanyole K, Stindel E, Le Goff-Pronost M. A pilot study on preferences from surgeons to deal with an innovative customized and connected knee prosthesis - A discret choice experiment. Heliyon 2024; 10:e30041. [PMID: 38784553 PMCID: PMC11112283 DOI: 10.1016/j.heliyon.2024.e30041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 05/25/2024] Open
Abstract
Background To address the increasing global demand for Total Knee Arthroplasty and reduce the need for revisions, several technologies combining 3D planning and artificial intelligence have emerged. These innovations aim to enhance customization, improve component positioning accuracy and precision. The integration of these advancements paves the way for the development of personalized and connected knee implant. Questions/purposes These groundbreaking advancements may necessitate changes in surgical practices. Hence, it is important to comprehend surgeons' intentions in integrating these technologies into their routine procedures. Our study aims to assess how surgeons' preferences will affect the acceptability of using this new implant and associated technologies within the entire care chain. Methods We employed a Discrete Choice Experiment, a predictive technique mirroring real-world healthcare decisions, to assess surgeons' trade-off evaluations and preferences. Results A total of 90 experienced surgeons, performing a significant number of procedures annually (mostly over 51) answered. Analysis indicates an affinity for technology but limited interest in integrating digital advancements like preoperative software and robotics. However, they are receptive to practice improvements and considering the adoption of future sensors. Conclusions In conclusion, surgeons prefer customized prostheses via augmented reality, accepting extra cost. Embedded sensor technology is deemed premature by them.
Collapse
Affiliation(s)
- Mathieu Le Stum
- Université de Brest, UBO, LATIM, UMR 1101, 22 rue Camille Desmoulins, 29200, Brest, France
- Institut National de la Santé et de la Recherche Médicale, Inserm, LaTIM, UMR 1101, 22 rue Camille Desmoulins, 29200, Brest, France
| | - Arnaud Clave
- Service d'orthopédie, Clinique Saint George, 2 Avenue de Rimiez, 06100, Nice, France
| | - Koffi Adzinyo Agbemanyole
- Institut Mines-Telecom, IMT Atlantique, LATIM, UMR 1101, M@rsouin, 655 Av. du Technopôle, 29280, Plouzané, France
| | - Eric Stindel
- Université de Brest, UBO, LATIM, UMR 1101, 22 rue Camille Desmoulins, 29200, Brest, France
- Centre Hospitalo-Universitaire de Brest, CHU Brest, LATIM, UMR 1101, 2 Avenue Foch, 29200, Brest, France
| | - Myriam Le Goff-Pronost
- Institut Mines-Telecom, IMT Atlantique, LATIM, UMR 1101, M@rsouin, 655 Av. du Technopôle, 29280, Plouzané, France
| |
Collapse
|
7
|
Vogel N, Kaelin R, Rychen T, Wendelspiess S, Müller-Gerbl M, Arnold MP. High Expectations Among Patients Who Have Undergone TKA Do Not Correlate With Satisfaction. Clin Orthop Relat Res 2024; 482:756-765. [PMID: 38416118 PMCID: PMC11008661 DOI: 10.1097/corr.0000000000003010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/24/2024] [Indexed: 02/29/2024]
Abstract
BACKGROUND One of five patients is dissatisfied with the outcome of TKA. With the increasing number of TKAs, this affects many patients. It has been suggested that high expectations may influence satisfaction, but the relationship between preoperative patient expectations and postoperative patient satisfaction remains poorly understood. QUESTIONS/PURPOSES (1) Are preoperative patient expectations correlated with postoperative satisfaction? (2) Are expectations correlated with patient characteristics or patient-reported outcome measures (PROMs)? (3) Is satisfaction correlated with patient characteristics or PROMs? (4) Do patients report specific items as more relevant to their expectations? METHODS This was a single-center, observational, retrospective, comparative study involving patients who underwent TKA. Between December 2020 and June 2022, three senior surgeons performed 306 TKAs. Of these, 76% (234) had the preoperative PROMs required for this study, and of these, 82% (193) had completed PROMs at the 12-month follow-up interval and were analyzed. Of the 193 included patients, 53% (102) were women; the mean age was 68 ± 9 years. Data were collected at baseline, 4 months, and 12 months. Twelve months of follow-up has been shown to be adequate in studies with PROMs. Patient expectations were measured using the validated Hospital for Special Surgery Knee Replacement Expectation Survey on a scale from 0 to 100, with higher scores indicating higher expectations. We also assessed patient satisfaction, the Knee injury and Osteoarthritis Outcome Score, Forgotten Joint Score, High-Activity Arthroplasty Score, EQ-5D-3L, and the objective Knee Society Score. Bivariate linear correlations were analyzed using the Pearson or Spearman test. RESULTS Preoperative patient expectations did not correlate with postoperative satisfaction. The mean Hospital for Special Surgery Knee Replacement Expectation Survey score was 82 ±16 points and did not correlate with satisfaction at either 4 months (r = -0.061; p = 0.42) or 12 months (r = -0.126; p = 0.11). Expectations did not correlate with patient characteristics or any of the preoperative or postoperative PROMs or the Knee Society Score. Patient satisfaction was 88% (158 of 179) at 4 months and 83% (160 of 193) at 12 months and did not correlate with patient characteristics or any of the preoperative PROMs or Knee Society Score. Patient satisfaction was medium to strongly correlated with postoperative PROMs and Knee Society Score. The Hospital for Special Surgery Knee Replacement Expectation Survey items with the most frequent expected improvement were "ability to walk" (99% [192 of 193]), "go downstairs" (99% [191 of 192]), and "go upstairs" (99% [192 of 193]). CONCLUSION Preoperative expectations were not correlated with postoperative satisfaction or PROMs. Surgeons should be aware that patients have high expectations. However, these expectations appear to be less relevant in determining postoperative satisfaction. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Nicole Vogel
- Practice Mein Knie, Hirslanden Klinik Birshof, Münchenstein, Switzerland
- Practice Leonardo, Hirslanden Klinik Birshof, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | - Raphael Kaelin
- Practice Leonardo, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Thomas Rychen
- Practice Leonardo, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Séverin Wendelspiess
- Practice Leonardo, Hirslanden Klinik Birshof, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | | | - Markus P. Arnold
- Practice Mein Knie, Hirslanden Klinik Birshof, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
8
|
Zhao R, Wei X, Hu S, Zhang Y, Wu H, Li P, Zhao Y. Deficient gait function despite effect index of the Western Ontario and McMaster university osteoarthritis index score considered cured one year after bilateral total knee arthroplasty. BMC Musculoskelet Disord 2024; 25:230. [PMID: 38521939 PMCID: PMC10960387 DOI: 10.1186/s12891-024-07348-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Accepted: 03/11/2024] [Indexed: 03/25/2024] Open
Abstract
BACKGROUND To clarify the value of gait analysis and its consistency with traditional scoring scales for the evaluation of knee joint function after total knee arthroplasty (TKA). METHODS This study included 25 patients with knee osteoarthritis (KOA) who underwent bilateral TKA, and 25 conditionally matched healthy individuals, categorised into the experimental and control groups, respectively. Patients in the experimental group underwent gait analysis and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) evaluation before and 1 year after TKA. Weight-bearing balance and walking stability were assessed using discrete trends of relevant gait indicators. Pearson's correlation analysis was performed on the gait and WOMAC score data of the experimental group before and after TKA. RESULTS One year after TKA, patients' gait indices (except gait cycle) were significantly better than before surgery, but significantly worse than that of the control group (P < 0.01). The shape of patients' plantar pressure curves did not return to normal. Additionally, the discrete trend of related gait indicators reflecting weight-bearing balance and walking stability were smaller than before TKA, but still greater than that of the control group. The WOMAC scores of patients 1 year after TKA were significantly lower than those before TKA (P < 0.001), and the efficacy index was > 80%. The WOMAC scores and gait analysis results were significantly correlated before TKA (P < 0.05). CONCLUSIONS Gait analysis should be used in conjunction with scoring scales to assess joint functions.
Collapse
Affiliation(s)
- Ruipeng Zhao
- Department of Orthopaedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, 382 Wuyi Road, Taiyuan, 030001, Shanxi, China
| | - Xiaochun Wei
- Department of Orthopaedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, 382 Wuyi Road, Taiyuan, 030001, Shanxi, China
| | - Shuai Hu
- Department of Orthopaedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, 382 Wuyi Road, Taiyuan, 030001, Shanxi, China
| | - Yixuan Zhang
- Department of Orthopaedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, 382 Wuyi Road, Taiyuan, 030001, Shanxi, China
| | - Hongru Wu
- Shanxi Institute of Sports Science, Taiyuan, 030001, Shanxi, China
| | - Pengcui Li
- Department of Orthopaedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, 382 Wuyi Road, Taiyuan, 030001, Shanxi, China
| | - Yu Zhao
- Department of Orthopaedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, 382 Wuyi Road, Taiyuan, 030001, Shanxi, China.
| |
Collapse
|
9
|
Saeed AZ, Khaleeq T, Ahmed U, Ajula R, Boutefnouchet T, D'Alessandro P, Malik SS. No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2024; 144:1311-1330. [PMID: 37979098 DOI: 10.1007/s00402-023-05090-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 09/25/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. METHODS A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. RESULTS Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69-2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95-9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53-3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD - 0.51(95% CI - 0.82 to - 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD - 0.27(95% CI - 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI - 3.69 to 6.70)]. CONCLUSION CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
Collapse
Affiliation(s)
- Abu Z Saeed
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK.
| | - Tahir Khaleeq
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK
| | - Usman Ahmed
- Worcestershire Acute Hospitals NHS Trust, Worcester, UK
| | - Randeep Ajula
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | - Peter D'Alessandro
- Orthopaedic Research Foundation of Western Australia, Medical School, Discipline of Surgery, University of Western Australia, Perth, Australia
| | | |
Collapse
|
10
|
Hirschmann MT, von Eisenhart-Rothe R, Graichen H, Vendittoli PA, Chen AF, Lustig S, Leal J, Tibesku C, Bonnin M. Neutrality, normality, abnormality and pathology in coronal knee alignment: Why and how should we define it in the era of personalised medicine? Knee Surg Sports Traumatol Arthrosc 2024; 32:515-517. [PMID: 38415940 DOI: 10.1002/ksa.12107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/09/2024] [Accepted: 02/13/2024] [Indexed: 02/29/2024]
Affiliation(s)
- Michael T Hirschmann
- Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, Switzerland
- Research Group Michael T. Hirschmann, Regenerative Medicine and Biomechanics, Department of Clinical Research, University of Basel, Basel, Switzerland
| | - Rüdiger von Eisenhart-Rothe
- Department of Orthopedics and Sports Orthopedics, Klinikum Rechts der Isar, Technical University Munich, München, Germany
| | - Heiko Graichen
- Department of Arthroplasty, Sports Medicine and Traumatology, Orthopaedic Hospital Lindenlohe, Schwandorf, Germany
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, Quebec, Canada
| | - Antonia F Chen
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Sebastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Joan Leal
- Department of Orthopaedic Surgery, Hospital Sant Joan de Déu de Manresa, Fundació Althaia (Spain), Universitat de Vic, Manresa, Spain
| | | | | |
Collapse
|
11
|
Campbell TM, Trudel G. Protecting the regenerative environment: selecting the optimal delivery vehicle for cartilage repair-a narrative review. Front Bioeng Biotechnol 2024; 12:1283752. [PMID: 38333081 PMCID: PMC10850577 DOI: 10.3389/fbioe.2024.1283752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Accepted: 01/15/2024] [Indexed: 02/10/2024] Open
Abstract
Focal cartilage defects are common in youth and older adults, cause significant morbidity and constitute a major risk factor for developing osteoarthritis (OA). OA is the most common musculoskeletal (MSK) disease worldwide, resulting in pain, stiffness, loss of function, and is currently irreversible. Research into the optimal regenerative approach and methods in the setting of either focal cartilage defects and/or OA holds to the ideal of resolving both diseases. The two fundamentals required for cartilage regenerative treatment are 1) the biological element contributing to the regeneration (e.g., direct application of stem cells, or of an exogenous secretome), and 2) the vehicle by which the biological element is suspended and delivered. The vehicle provides support to the regenerative process by providing a protective environment, a structure that allows cell adherence and migration, and a source of growth and regenerative factors that can activate and sustain regeneration. Models of cartilage diseases include osteochondral defect (OCD) (which usually involve one focal lesion), or OA (which involves a more diffuse articular cartilage loss). Given the differing nature of these models, the optimal regenerative strategy to treat different cartilage diseases may not be universal. This could potentially impact the translatability of a successful approach in one condition to that of the other. An analogy would be the repair of a pothole (OCD) versus repaving the entire road (OA). In this narrative review, we explore the existing literature evaluating cartilage regeneration approaches for OCD and OA in animal then in human studies and the vehicles used for each of these two conditions. We then highlight strengths and challenges faced by the different approaches presented and discuss what might constitute the optimal cartilage regenerative delivery vehicle for clinical cartilage regeneration.
Collapse
Affiliation(s)
- T. Mark Campbell
- Elisabeth Bruyère Hospital, Ottawa, ON, Canada
- Bone and Joint Research Laboratory, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- Department of Cellular and Molecular Medicine, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada
| | - Guy Trudel
- Bone and Joint Research Laboratory, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- Department of Cellular and Molecular Medicine, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada
- The Ottawa Hospital, Department of Medicine, Division of Physical Medicine and Rehabilitation, Ottawa, ON, Canada
| |
Collapse
|
12
|
Vogel N, Kaelin R, Rychen T, Wendelspiess S, Müller-Gerbl M, Arnold MP. Satisfaction after total knee arthroplasty: a prospective matched-pair analysis of patients with customised individually made and off-the-shelf implants. Knee Surg Sports Traumatol Arthrosc 2023; 31:5873-5884. [PMID: 37982843 PMCID: PMC10719143 DOI: 10.1007/s00167-023-07643-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Accepted: 10/17/2023] [Indexed: 11/21/2023]
Abstract
PURPOSE Customised individually made (CIM) total knee arthroplasty (TKA) was introduced to potentially improve patient satisfaction and other patient-reported outcome measures (PROMs). The purpose of this study was to compare PROMs, especially patient satisfaction, of patients with CIM and OTS TKA in a matched-pair analysis with a 2-year follow-up. METHODS This is a prospective cohort study with a propensity score matching of 85 CIM and 85 off-the-shelf (OTS) TKA. Follow-up was at 4 months, 1 year and 2 years. The primary outcome was patient satisfaction. Secondary outcomes were as follows: overall improvement, willingness to undergo the surgery again, Knee injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score (FJS-12), High-Activity Arthroplasty Score (HAAS), EQ-5D-3L, EQ-VAS, Knee Society Score (KSS) and surgeon satisfaction. RESULTS Patient satisfaction ranged from 86 to 90% and did not differ between CIM and OTS TKA. The EQ-VAS after 4 months and the HAAS after 1 year and 2 years were higher for CIM TKA. KOOS, FJS-12 and EQ-5D-3L were not different at follow-up. The changes in KOOS symptoms, pain and daily living were higher for OTS TKA. The KSS was higher for patients with CIM TKA. Surgeon satisfaction was high throughout both groups. Patients who were satisfied after 2 years did not differ preoperatively from those who were not satisfied. Postoperatively, all PROMs were better for satisfied patients. Patient satisfaction was not correlated with patient characteristics, implant or preoperative PROMs, and medium to strongly correlated with postoperative PROMs. CONCLUSION Patient satisfaction was high with no differences between patients with CIM and OTS TKA. Both implant systems improved function, pain and health-related quality of life. Patients with CIM TKA showed superior results in demanding activities as measured by the HAAS. LEVEL OF EVIDENCE II, prospective cohort study.
Collapse
Affiliation(s)
- Nicole Vogel
- Practice MEIN KNIE, Hirslanden Klinik Birshof, Reinacherstrasse 42, 4142, Münchenstein, Switzerland.
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland.
- Faculty of Medicine, University of Basel, Basel, Switzerland.
| | - Raphael Kaelin
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Thomas Rychen
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Séverin Wendelspiess
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | | | - Markus P Arnold
- Practice MEIN KNIE, Hirslanden Klinik Birshof, Reinacherstrasse 42, 4142, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
13
|
Sajan M, Moussa MK, Lefèvre N, Payan C, Valentin E, Meyer A, Bohu Y, Khalaf Z, Grimaud O, Gerometta A, Hardy A, Khiami F. Customized-individually-made origin® implants in total knee arthroplasty allow a reliable solution for accurate reproduction of planned implant positioning. J Exp Orthop 2023; 10:123. [PMID: 38015319 PMCID: PMC10684845 DOI: 10.1186/s40634-023-00706-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 11/17/2023] [Indexed: 11/29/2023] Open
Abstract
PURPOSE To evaluate the accuracy and reproducibility of a patient-specific, customized individually made (CIM) total knee replacement (TKR) using the ORIGIN® prosthesis. METHODS This was a prospective study conducted at a University Hospital from January 15, 2019, to April 30, 2021. The study included patients planned for an ORIGIN® CIM TKR procedure. Exclusion criteria included revision surgery, severe deformity, stiffness, or laxity. Evaluations were carried out using computed tomography scans performed 8 weeks preoperatively and 6 weeks postoperatively. The primary outcome measurements were the preoperative, planned, and postoperative CT scan alignment measurements including the Hip-Knee-Ankle (HKA) angle, mechanical Medial Distal Femoral articular surface Angle (mMDFA, distal alpha angle), Posterior Distal femoral articular surface angle (PDFA, posterior alpha angle), mechanical Medial Proximal Tibial articular surface Angle (mMPTA, beta angle) and posterior proximal tibial angle (PPTA). Secondary outcomes included the accuracy of implant positioning with percentage of outliers at 2° and 3° RESULTS: The study encompassed 51 knees from 50 patients with mean age of 68.1 (SD = 8.89). The overall HKA angle deviated by -0.93° [95% CI: -1.45; -0.43], and the PDFA angle by -0.61° [95% CI: -1.07; -0.15], while the mMPTA exceeded planned values by 1.00° [95% CI: 0.57; 1.43]. The 3° outliers rate ranged from 3.9% for the mMPTA to 7.8% for the HKA alignment, with no outliers in mMDFA and PPTA. Similarly, the 2° outliers rate ranged from 15.7% for both the PDFA angle and mMPTA to 19.6% for the HKA alignment. The Bland-Altman plots further emphasized the precision of planned and post-operative angles across all measurements. CONCLUSION The CIM TKR showed high accuracy and reproducibility, closely matching preoperative planning. The weakest accuracy at 3°-outliers is in the reproduction of the HKA alignment at 92.2% (range for all angle: 92.2-100%). Similarly, the weakest accuracy at 2°-outliers is in the reproduction of the HKA alignment at 80.4% (range for all angles: 80.4-92.2%).
Collapse
Affiliation(s)
- Martin Sajan
- Hôpital de la Pitié Salpêtrière-AP-HP, 75013, Paris, France
| | - Mohamad K Moussa
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France.
| | - Nicolas Lefèvre
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | | | - Eugénie Valentin
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | - Alain Meyer
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | - Yoann Bohu
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | - Zeinab Khalaf
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | - Olivier Grimaud
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | | | - Alexandre Hardy
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| | - Frédéric Khiami
- Clinique du sport, 36 Boulevard Saint-Marcel, 75005, Paris, France
| |
Collapse
|
14
|
Nguyen VD, LaCour MT, Dessinger GM, Komistek RD. Advancements in total knee arthroplasty kinematics: 3D implant computer aided design model creation through X-ray or fluoroscopic images. Clin Biomech (Bristol, Avon) 2023; 109:106091. [PMID: 37696164 DOI: 10.1016/j.clinbiomech.2023.106091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 08/30/2023] [Accepted: 09/05/2023] [Indexed: 09/13/2023]
Abstract
BACKGROUND 3D-to-2D fluoroscopic registration is a popular and important step for analyzing total-knee-arthroplasty weight-bearing kinematics. Unfortunately, in vivo analyses using these techniques cannot be completed if the associated computer-aided design implant models are not available. This study introduces a novel method that enables the accessible computation of knee replacement patients' kinematics from fluoroscopy, achieved through the reconstruction of 3-dimensional knee component models using a limited set of 2-dimensional X-ray or fluoroscopic images. METHODS The proposed non-rigid morphing algorithm, based on the coherent point drift algorithm, scales and transforms the shape of the template model to fit with the silhouette of the corresponding fluoroscopic images without changing the structure of the knee implant. While a greater number of fluoroscopic images can lead to higher accuracy, our study utilizes only 4 images. FINDINGS The morphed models show excellent results in comparison with known models with a 0.52 mm average root-mean-square error and a 2.82 mm largest source error for 17 tested knee models of various implant types. The proposed algorithm also enables direct output of patient kinematics using fluoroscopy, with an average error of only 0.54 ± 0.42 mm for femorotibial contact and 0.86 ± 0.34 degrees for axial rotation. INTERPRETATION A novel methodology was introduced to overcome common 3-dimentional to 2-dimensional registration limitations by recreating entire families of 3 dimensional models from a limited number of fluoroscopic images for both cruciate-retaining and posterior-stabilized knee replacement implants. Our algorithm has demonstrated high levels of accuracy with multiple potential extended applications.
Collapse
|
15
|
Choudhury AK, Gupta K, Ansari S, Raja BS, Paul S, Kalia RB. Modern implants in total knee arthroplasty are more patellofemoral joint friendly compared to their traditional design: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2023; 143:5873-5889. [PMID: 36961568 DOI: 10.1007/s00402-023-04832-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Accepted: 02/28/2023] [Indexed: 03/25/2023]
Abstract
BACKGROUND Implant designs for total knee arthroplasties (TKA) are continuously evolving to improve outcomes and satisfaction rates after TKA. The present systematic review and meta-analysis aimed to explore the evidence in the literature regarding the outcomes of the Attune knee system over the PFC Sigma knee design and investigate the advantage of one over the other. METHODS A systematic review and meta-analysis of published studies till August 2021 was performed using the defined eligibility criteria. This was a systematic review of the literature published in the Cochrane Central Register of Controlled Trials (CENTRAL) Library, PUBMED, and EMBASE. The analysis included prospective and retrospective comparative trials comparing TKA by PFC sigma or Attune posterior stabilized (PS) or cruciate-retaining (CR), fixed bearing, or rotating platform systems. Patient-reported outcome measures (PROM) and postoperative patellar complications were analysed in the studies utilizing attune knee system (modern implants) to its counterpart PFC sigma (traditional implants) for TKA. Quality assessment was conducted using NIH Quality Assessment Tool for controlled intervention studies (RCTs and case-control studies). RESULTS This review included 3 RCTs and the rest, 10 of which were non-RCT, including 5852 patients. ATTUNE designs suggested a statistically significant improvement in KSS over PFC Sigma designs. Other PROMs such as OKS and WOMAC scores yielded comparable results between the two groups. ATTUNE knee prosthesis did not result in better knee range of motion, patient satisfaction, or radiological outcomes than the PFC design. Regarding the complications, attune knee prosthesis demonstrated favourable results over PFC Sigma for anterior knee pain and patellofemoral (PF) crepitus. CONCLUSIONS The present systematic review highlights better KSS and lesser chances of PF complications favouring a modern implant design over its traditional counterpart. Other patient-reported outcome analyses at a short-term follow-up period were comparable among patients undergoing total knee replacements with two different implant designs. Radiological outcomes for component positioning also suggested similar results among the two groups.
Collapse
Affiliation(s)
- Arghya Kundu Choudhury
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Kshitij Gupta
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Sajid Ansari
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Balgovind S Raja
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Souvik Paul
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Roop Bhushan Kalia
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India.
| |
Collapse
|
16
|
Buschner P, Toskas I, Huth J, Beckmann J. Improved Knee Function with Customized vs. Off-the-Shelf TKA Implants-Results of a Single-Surgeon, Single-Center, Single-Blinded Study. J Pers Med 2023; 13:1257. [PMID: 37623507 PMCID: PMC10456041 DOI: 10.3390/jpm13081257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/02/2023] [Accepted: 08/10/2023] [Indexed: 08/26/2023] Open
Abstract
BACKGROUND Recent studies have been able to show certain benefits of Customized, Individually Made (CIM) compared to Off-the-Shelf (OTS) total knee arthroplasties (TKAs), but evidence is still lacking regarding the benefits of these implant systems. This study aimed to find differences in scores and functional outcome by comparing CIM and OTS implants, using Patient-Reported Outcome Measures (PROMs) and functional tests for activities of daily living in a single-surgeon setup. METHODS A total of 48 patients (16 CIM vs. 32 OTS) were consecutively enrolled and blindly examined. Functional testing was performed using four timed functional tests (TUG, WALK, TUDS, and BBS) and the VAS for pain. The Aggregated Locomotor Function (ALF) score was then calculated based on the addition of the average times of the three functional tests. RESULTS The CIM group showed significantly faster times in all functional tests and significantly better ALF scores. There were remarkable differences in the assessment of maximum pain sensation between the two groups, with superiority in the CIM group. The PROMs analysis revealed a higher proportion of excellent and good ratings for the items objective and function (KSS) in the CIM group. CONCLUSION The study showed that time-limited activities of daily living (ADLs) can be completed significantly faster with a CIM prosthesis and that a significantly higher percentage in this group reports freedom from pain during certain loads. Partial aspects of the PROM scores are also better in this group; however, this superiority could not be shown with regard to most PROM scores collected in this study.
Collapse
Affiliation(s)
- Peter Buschner
- Clinic for Orthopaedics and Traumatology, Krankenhaus Barmherzige Brüder München, 80639 Munich, Germany
| | | | - Jochen Huth
- Sportklinik Stuttgart, 70372 Stuttgart, Germany
| | - Johannes Beckmann
- Clinic for Orthopaedics and Traumatology, Krankenhaus Barmherzige Brüder München, 80639 Munich, Germany
| |
Collapse
|
17
|
Le Stum M, Bertin T, Le Goff-Pronost M, Apremont C, Dardenne G, Rolland-Lozachmeur G, Stindel E. Three-Dimensional Printed Knee Implants: Insights into Surgeons' Points of View. J Pers Med 2023; 13:jpm13050811. [PMID: 37240981 DOI: 10.3390/jpm13050811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 05/05/2023] [Accepted: 05/06/2023] [Indexed: 05/28/2023] Open
Abstract
Three-dimensional printing is a technology that has been developed and applied in several medical specialties, especially orthopedic surgery. Knee arthroplasty is the most commonly performed procedure. To fit the morphology of each knee, surgeons can choose between different standardized off-the-shelf implant sizes or opt for customized 3D-printed implants. However, routine adoption of the latter has been slow and faces several barriers. Existing studies focus on technical improvements or case studies and do not directly address the surgeon's perspective. Our study invited surgeons to express themselves freely and answer the question "What do you think about the manufacture of a prosthesis by 3D printing?". The questionnaire was completed by 90 surgeons. On average, they had more than 10 years of experience (52, 57.8% ± 10.2%), worked in public hospitals (54, 60% ± 10.1%), and performed between 0 and 100 prostheses per year (60, 66.7% ± 9.7%). They also reported not using planning software (47, 52.2% ± 9.7%), navigation systems, or robots (62, 68.9% ± 9.6%). Regarding the use of technological innovation, they agreed on the extra surgical time needed (67, 74.4% ± 9.0%). The answers obtained were classified according to two criteria: (i) opinions, and (ii) motivations. Among the respondents, 51 (70% ± 9.5%) had positive and 22 (30% ± 9.5%) had negative opinions about 3D printing. The motivations were distributed among seven categories (surgery, materials, costs, logistics, time, customization, and regulatory) and mainly related to "pre-surgery" and "post-surgery" concerns. Finally, the results showed that the use of navigation systems or robots may be associated with a more positive view of 3DP. The purpose of our study was to examine knee surgeons' perceptions of 3DP at a time of significant expansion of this technology. Our study showed that there was no opposition to its implementation, although some surgeons indicated that they were waiting for validated results. They also questioned the entire supply chain, including hospitals, insurance companies, and manufacturers. Although there was no opposition to its implementation, 3D printing is at a crucial point in its development and its full adoption will require advances in all areas of joint replacement.
Collapse
Affiliation(s)
- Mathieu Le Stum
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Institut National de la Santé et de la Recherche Médicale, INSERM, 29200 Brest, France
| | - Thomas Bertin
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
| | - Myriam Le Goff-Pronost
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, M@rsouin, Institut Mines-Telecom, IMT Atlantique, 29200 Brest, France
| | - Claire Apremont
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
| | - Guillaume Dardenne
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Centre Hospitalo-Universitaire de Brest, CHU Brest, 29200 Brest, France
| | - Ghislaine Rolland-Lozachmeur
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
| | - Eric Stindel
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Centre Hospitalo-Universitaire de Brest, CHU Brest, 29200 Brest, France
| |
Collapse
|
18
|
Personalisation and customisation in total knee arthroplasty: the paradox of custom knee implants. Knee Surg Sports Traumatol Arthrosc 2023; 31:1193-1195. [PMID: 36934205 DOI: 10.1007/s00167-023-07385-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/20/2023]
|
19
|
Gousopoulos L, Dobbelaere A, Ratano S, Bondoux L, Tibesku CO, Aït-Si-Selmi T, Bonnin MP. Custom total knee arthroplasty combined with personalised alignment grants 94% patient satisfaction at minimum follow-up of 2 years. Knee Surg Sports Traumatol Arthrosc 2023; 31:1276-1283. [PMID: 36656348 DOI: 10.1007/s00167-023-07318-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 01/05/2023] [Indexed: 01/20/2023]
Abstract
PURPOSE The purpose was to report detailed patient-reported outcome measures (PROMs) and satisfaction rates for computed tomography (CT)-based custom TKA at minimum follow-up of 2 years. The hypothesis was that custom TKA combined with 'personalised alignment' would yield equivalent or better PROMs compared to values reported in systematic reviews and meta-analyses on off-the-shelf (OTS) TKA. METHODS Of an initial cohort of 150 custom TKAs, four died (unrelated to surgery), one required a revision, and five refused participation, leaving 140 patients for analysis. Patients completed pre- and post-operative PROMs (Oxford Knee Score (OKS), Forgotten Joint Score (FJS), Knee injury and Osteoarthritis Outcome Score (KOOS), Western Ontario and McMaster osteoarthritis index (WOMAC)) as well as overall level of satisfaction. Proportions that attained a patient acceptable symptom state (PASS) were calculated for OKS and FJS. Clinical findings were compared to the average scores reported for PROMs in recent systematic reviews and/or meta-analyses on OTS TKA. Descriptive statistics were used to summarise the clinical findings as means, standard deviations (SD) and ranges, or numbers and percentages. RESULTS At mean follow-up 33.5 ± 4.5 months, 94% (135/143) were either satisfied or very satisfied. Proportions that achieved PASS were 89% for OKS (120/135), and 85% for FJS (118/139). Median OKS, WOMAC and KOOS Symptoms and Pain scores were all within the 4th quartile of medians reported in systematic reviews and/or meta-analyses. CONCLUSIONS At a minimum follow-up of two years following custom TKA combined with 'personalised alignment', 94% of patients were either satisfied or very satisfied, and the PASS criteria were achieved in 89% for OKS and 85% for FJS, all of which compare favourably to published outcomes of OTS TKA. Direct comparisons to the literature may not be appropriate, however, considering the heterogeneity of patient demographics and alignment techniques. Randomised controlled trials with sufficient statistical power are needed to corroborate these findings and generalise them to unselected TKA patients. LEVEL OF EVIDENCE IV, retrospective cohort study.
Collapse
Affiliation(s)
- Lampros Gousopoulos
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Andreas Dobbelaere
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Salvatore Ratano
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Louka Bondoux
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | | | - Tarik Aït-Si-Selmi
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Michel P Bonnin
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| |
Collapse
|
20
|
Custom TKA combined with personalised coronal alignment yield improvements that exceed KSS substantial clinical benefits. Knee Surg Sports Traumatol Arthrosc 2022; 30:2958-2965. [PMID: 35182169 DOI: 10.1007/s00167-022-06867-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/31/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE The purpose of this study was to report Knee Society Scores (KSS) at 12-month follow-up in a series of 266 knees that received custom TKA. The hypothesis was that custom TKA combined with personalised alignment would yield improvements greater than substantial clinical benefits (SCB) of KSS Knee and Function. METHODS From a consecutive series of 905 patients (918 knees) that received primary TKAs, 261 (29%) patients (266 knees) received computed tomography (CT)-based posterior-stabilised cemented custom TKA. Knees were aligned aiming to preserve or restore constitutional alignment within predetermined limits of 85°-95° for femoral mechanical angle (FMA) and tibial mechanical angle (TMA), and 175°-183° for hip knee ankle (HKA) angle. The KSS Knee and Function were collected preoperatively and 12 months postoperatively, to determine if patients achieved SCB. Uni- and multivariable analyses were performed to determine associations between KSS scores (Knee and Function) and patient demographics as well as pre- and postoperative radiographic alignments. RESULTS Of the initial cohort of 261 patients, 4 (1.8%) were reoperated for patellar resurfacing, 1 (0.4%) for lavage to treat infection, and 1 (0.4%) had arthroscopy to treat a stiff knee with < 90° range of motion. Complete clinical records were available for 227 patients (232 knees, 87%) that comprised 102 men (5 bilateral) and 125 women. At 12-month follow-up, mean improvements in KSS Knee and Function scores were, respectively, 61.0 ± 13.0 and 42.7 ± 16.7, which exceeded the SCB of KSS. Comparison of knees inside versus outside the target zone revealed no differences in KSS Knee (94.1 ± 9.1 versus 94.3 ± 9.0, n.s.) and Function (96.1 ± 9.2 versus 96.3 ± 8.9, n.s.). Multivariable analysis revealed worse KSS Knee in knees with preoperative FMA > 95° (β = - 6.21; p = 0.023), but no association between KSS Function and patient demographics or pre- and postoperative radiographic alignments. CONCLUSIONS Custom TKA combined with personalised alignment yielded improvements that exceeded substantial clinical benefits of KSS Knee and Function scores. These findings demonstrate the feasibility of custom TKA with 'personalised alignment' and encourage further investigations using comparative studies at longer follow-up. LEVEL OF EVIDENCE IV, case series.
Collapse
|
21
|
Mawarikado Y, Inagaki Y, Fujii T, Imagita H, Fukumoto T, Kubo T, Shirahase M, Kido A, Tanaka Y. Preoperative Factors Affecting Patient-reported Outcome Measures for Total Knee Arthroplasty. Prog Rehabil Med 2022; 7:20220049. [PMID: 36188140 PMCID: PMC9475053 DOI: 10.2490/prm.20220049] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Accepted: 08/30/2022] [Indexed: 11/17/2022] Open
Abstract
Objectives: The aim of this study was to investigate the preoperative factors affecting health-related quality of life (HRQOL) at 3 and 12 months after total knee arthroplasty (TKA). Methods: In total, 156 patients who underwent unilateral TKA for knee osteoarthritis were included in the study. The Knee Injury and Osteoarthritis Outcome Score (KOOS) was used as a measure of HRQOL before surgery and 3 and 12 months post-TKA. The Modified Gait Efficacy Scale (mGES) score, tibiofemoral angle, rest pain, walking pain, knee joint range of motion, knee joint extensor strength, and walking speed were recorded preoperatively. Pearson’s correlation coefficient and the correlation ratio were used to calculate the correlation between KOOS and preoperative factors at 3 and 12 months post-TKA. Multiple regression analysis was performed using the stepwise method with the five postoperative KOOS subscales as dependent variables and the other preoperative factors as independent variables. Results: Preoperative mGES scores were significantly correlated with KOOS Activities of Daily Living, Sport/Rec, and QOL subscores at 3 months post-TKA and with all five KOOS subscales at 12 months post-TKA. Multiple regression analysis identified mGES as an influencing factor for all KOOS subscales except Pain at 3 months post-TKA and all KOOS subscales except Symptoms at 12 months post-TKA. Conclusions: Preoperative walking self-efficacy influenced HRQOL at 3 and 12 months post-TKA. Psychological factors such as self-efficacy should be considered when predicting postoperative outcomes.
Collapse
Affiliation(s)
- Yuya Mawarikado
- Graduate School of Medicine, Musculoskeletal Reconstructive Surgery, Nara Medical University, Nara, Japan
| | - Yusuke Inagaki
- Graduate School of Medicine, Musculoskeletal Reconstructive Surgery, Nara Medical University, Nara, Japan
| | - Tadashi Fujii
- Department of Orthopedic Surgery, Kashiba Asahigaoka Hospital
| | - Hidetaka Imagita
- Graduate School of Health Sciences, Saitama Prefectural University
| | | | - Takanari Kubo
- Department of Rehabilitation, Osaka Kawasaki Rehabilitation University
| | - Mimo Shirahase
- Department of Rehabilitation, Kishiwada Rehabilitation Hospital
| | - Akira Kido
- Department of Rehabilitation Medicine, Nara Medical University
| | - Yasuhito Tanaka
- Graduate School of Medicine, Musculoskeletal Reconstructive Surgery, Nara Medical University, Nara, Japan
| |
Collapse
|