1
|
Tarrant SA, Mitchell BP, Blankespoor MG, Littell ZD, Zackula RE, Lais RL, Dart BR. Outcomes of internal fixation with Femoral Neck System (FNS) for intracapsular femoral neck fractures. OTA Int 2024; 7:e346. [PMID: 39301534 PMCID: PMC11410314 DOI: 10.1097/oi9.0000000000000346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 06/22/2024] [Accepted: 07/12/2024] [Indexed: 09/22/2024]
Abstract
Background Internal fixation of hip fractures is associated with high reoperation rates. This study investigated the reoperation rates after internal fixation with the femoral neck system (FNS). Materials and Methods A single-institution cohort study was conducted on patients aged 18 years or older who sustained intracapsular femoral neck fractures and underwent internal fixation with a fixed-angle implant. Surgeons, patients, and investigators were not blinded. The primary outcome was any hip reoperation at the final follow-up. Secondary outcomes were to characterize a cohort of patients regarding demographics, fracture classification, intraoperative findings, postoperative fracture complications and union rates, and postoperative pain. Results This study found that internal fixation with FNS for intracapsular femoral neck fractures was associated with a 23% rate of revision surgery. Of the initial 94 patients who received FNS internal fixation, 44 patients were included for analysis; of those, 10 patients underwent revision surgery. Patients had a 22% rate of in-hospital medical adverse events with a 30-day readmission rate of 9%. Increasing body mass index was associated with increased revision rates (P = 0.037). Patients who sustained displaced femoral neck fractures had a significant decrease in SF-12 Mental Health Composite, SF-12 Physical Health Composite, and quality-of-life subscale scores. Conclusions The FNS is a viable alternative for internal fixation of intracapsular femoral neck fractures. The observed rate of revision after internal fixation was comparable with previously published outcomes following fixation with cannulated screws and sliding hip screws. Level of Evidence Level IV, Therapeutic Study.
Collapse
Affiliation(s)
- Seth A Tarrant
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
- Department of Orthopaedic Surgery, KU SOM-Wichita, Wichita, KS
| | - Brendan P Mitchell
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
- Department of Orthopaedic Surgery, KU SOM-Wichita, Wichita, KS
| | - Michael G Blankespoor
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
- Department of Orthopaedic Surgery, KU SOM-Wichita, Wichita, KS
| | - Zane D Littell
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
| | - Rosalee E Zackula
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
- Office of Research, KU SOM-Wichita, Wichita, KS
| | - Randall L Lais
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
- Department of Orthopaedic Surgery, KU SOM-Wichita, Wichita, KS
- Advanced Orthopaedic Associates, PA, Wichita, KS
| | - Bradley R Dart
- University of Kansas School of Medicine-Wichita (KU SOM-Wichita), Wichita, KS
- Department of Orthopaedic Surgery, KU SOM-Wichita, Wichita, KS
- Advanced Orthopaedic Associates, PA, Wichita, KS
| |
Collapse
|
2
|
Chan CX, Lim JI, Singh A, Murphy D, Chen Y. Two-year outcomes of internal fixation with femoral neck system in patients with femoral neck fracture in an Asian population. J Orthop 2024; 57:98-103. [PMID: 39006207 PMCID: PMC11245931 DOI: 10.1016/j.jor.2024.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 06/10/2024] [Indexed: 07/16/2024] Open
Abstract
Background Femoral neck fractures (FNF) are one of the most common fractures, with a projected increase in incidence with population growth and ageing. The Femoral Neck System (FNS) launched in 2019 was developed specifically for fixation of FNF with the purported advantages of providing both angular and rotational stability. We report our experience with the FNS and evaluate its effectiveness and associated complications. Methods A retrospective case series of 50 patients who underwent surgical fixation for FNF from August 2020 to October 2021 using the FNS in two Singapore tertiary institutions with at least 2 years follow-up were included. Clinical data (patients' demographics, fracture classification, intra-operative and post-operative complications) were reviewed. Radiological analysis assessed the pre- and immediate post-operative garden alignment index (GAI) and presence of femoral neck shortening at 3 months. Results The mean age was 63.5 years (SD 16.9, range 26-92). Five (10 %), 34 (68 %) and 11 (22 %) were ASA 1, 2 and 3 respectively. Twenty-four (48 %), 16 (32 %), 4 (8 %), and 6 (12 %) patients sustained Garden's 1, 2, 3 and 4 FNF respectively. The mean operative duration was 66.2 min (SD 20.5) and length of stay was 6.9 days (SD 4.6).The post-operative improvement in garden alignment index (GAI) was a mean of 9.1° (p < 0.001) on lateral view. The mean femoral neck shortening was 1.97 mm (SD 5.3) at 3 months. There were no intra-operative complications. Post-operatively, 1 (2 %) patient required blood transfusion, 1 (2 %) patient had implant cut-out and non-union managed non-operatively, 2 (4 %) patients developed avascular necrosis and required revision to total hip replacements. There were two (4 %) cases of 1-year mortality. Conclusion The FNS achieved good outcomes with low rates of complications. The promising results justify its continued use and further evaluation in comparison to other devices.
Collapse
Affiliation(s)
- Chloe Xiaoyun Chan
- Department of Orthopaedic Surgery, National University Hospital, National University Health System (NUHS), Singapore, 5 Lower Kent Ridge Road, 119074, Singapore
- Department of Orthopaedic Surgery, Ng Teng Fong General Hospital, National University Health System (NUHS), Singapore, 1 Jurong East Street 21, 609606, Singapore
| | - Joshua Ian Lim
- Department of Orthopaedic Surgery, Ng Teng Fong General Hospital, National University Health System (NUHS), Singapore, 1 Jurong East Street 21, 609606, Singapore
| | - Amritpal Singh
- Department of Orthopaedic Surgery, National University Hospital, National University Health System (NUHS), Singapore, 5 Lower Kent Ridge Road, 119074, Singapore
- Department of Orthopaedic Surgery, Ng Teng Fong General Hospital, National University Health System (NUHS), Singapore, 1 Jurong East Street 21, 609606, Singapore
| | - Diarmuid Murphy
- Department of Orthopaedic Surgery, National University Hospital, National University Health System (NUHS), Singapore, 5 Lower Kent Ridge Road, 119074, Singapore
| | - Yongsheng Chen
- Department of Orthopaedic Surgery, National University Hospital, National University Health System (NUHS), Singapore, 5 Lower Kent Ridge Road, 119074, Singapore
- Department of Orthopaedic Surgery, Ng Teng Fong General Hospital, National University Health System (NUHS), Singapore, 1 Jurong East Street 21, 609606, Singapore
| |
Collapse
|
3
|
Wang M, Zhang Z, Sun F, Zhu Y, Han R, Pei Z, He Z, Liu J, Wen L. Global trends of Pauwels type III femoral neck fractures: bibliometric analysis and visualized study. Front Surg 2024; 11:1372310. [PMID: 39351289 PMCID: PMC11439767 DOI: 10.3389/fsurg.2024.1372310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Accepted: 08/28/2024] [Indexed: 10/04/2024] Open
Abstract
Background Pauwels type III femoral neck fractures, as a serious type of femoral neck fractures, have brought about a heavy economic burden on families and society for the high disability rate. Through bibliometric research and visualized analysis, this study aimed at elucidating the global research status of Pauwels type III femoral neck fractures to date, and predicting the future research trends in this field. Methods Publications and associated information on Pauwels type III femoral neck fractures to date were retrieved from Web of Science Core Collection, and by VoSviewer and R package "bibliometrix", bibliometric analysis and visual presentation was conducted. Results By retrieval, a total of 98 studies were refinedly extracted, and the volume of publications in this field increased year-over-year. China ranked first in terms of total publication volume and H-Index, with its total citation records second only to the United States. The country with the highest average citation frequency was Switzerland. SHANGHAI JIAO TONG UNIVERSITY was the most productive research institution. Among the authors in this field, Li, Jiantao had published the most researches. INJURY INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED and JOURNAL OF ORTHOPAEDIC TRAUMA were the two magazines with the highest publication volume, total citation records, and H-index. According to keywords co-occurrence analysis, the research content in the past 24 years is mainly divided into four different dimensions. Finite element analysis, femoral neck system, medial buttress plate, cannulated screws, hip screw, open reduction, complications are hot topics for future research. Conclusions According to the global trends analysis of publications production, Pauwels type III femoral neck fractures are receiving increasing attention and input from scholars. China has made the greatest scientific research contribution among countries, but its academic quality should be improved further. The modified therapeutic methods designed for addressing the complications of traditional internal fixation for Pauwels III femoral neck fractures will be the future research hotspot.
Collapse
Affiliation(s)
- Mengyu Wang
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
- The Fifth Clinical Medical College of Perking University, Beijing, China
| | - Ze Zhang
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
- Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences &Peking Union Medical College, Beijing, China
| | - Fengpo Sun
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Yi Zhu
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Ruining Han
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Zijie Pei
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Zhaoshuo He
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Junzhi Liu
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Liangyuan Wen
- Department of Orthopedics, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
- Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences &Peking Union Medical College, Beijing, China
| |
Collapse
|
4
|
Zhai Q, Wang F, He X, Zhou K, Chen N. Revision rate of displaced femoral neck fractures in non-elderly adults: a retrospective comparative study of the femoral neck system and cannulated screws. J Orthop Surg Res 2024; 19:571. [PMID: 39285432 PMCID: PMC11406837 DOI: 10.1186/s13018-024-05056-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2024] [Accepted: 09/02/2024] [Indexed: 09/19/2024] Open
Abstract
BACKGROUND Displaced femoral neck fractures are associated with a high revision rate. The new femoral neck system(FNS) offers advantages in fixation stability, potentially reducing the need for revision. The purpose of this study was to compare the revision rate of patients with different reduction quality treated with the FNS and cannulated screws (CS). METHODS This retrospective study included patients with Garden III or IV femoral neck fractures who underwent osteosynthesis in a level 1 trauma center between July 2019 and June 2023. A total of 141 cases met the inclusion criteria and received treatment with either the FNS (N = 65) or CS (N = 76). The quality of fracture reduction, surgical complications (such as femoral neck shortening, avascular necrosis of femoral head, nonunion of fracture, implant failure and withdrawal), revision surgery and the reasons for revision were analyzed. RESULTS The mean age of the 141 cases was 52.0 years (range 18-65); with sixty-five cases being male (46.1%). Eighty-four fractures (59.6%) were classified as Garden type III. Reduction quality was good in 71 cases (50.4%) and fair in 70 cases. The mean follow-up period was 25.9 months (range 12-46). A total of 26 cases(18.4%) underwent revision surgery. The revision rate in cases with good reduction was 11.3% (8/71 cases), with seven cases (four hardware removal and three arthroplasty) in the CS group and one case (arthroplasty for fracture nonunion and implant failure) in the FNS group, a significant difference was found between the two groups(P = 0.041). Among the 18 cases (25.7%, 18/70) with fair reduction who underwent revision surgery, nine cases (six hardware removal and three arthroplasty) in the CS group, and nine cases (arthroplasty for implant failure and cut-out) in the FNS group, and there was no significant difference between the two groups (P = 0.672). The total revision rate between the FNS group (15.4%, 10/65) and the CS group (21.1%, 16/76) was not significantly different (P = 0.387). CONCLUSIONS The total revision rate between the FNS and CS group showed no difference. However, in cases with good reduction, the revision rate was lower in the FNS group compared to the CS group.
Collapse
Affiliation(s)
- Qilin Zhai
- Qingpu Branch of Zhongshan Hospital Affiliated to Fudan University, Shanghai, China
| | - Fuyong Wang
- Qingpu Branch of Zhongshan Hospital Affiliated to Fudan University, Shanghai, China
| | - Xiaojian He
- Qingpu Branch of Zhongshan Hospital Affiliated to Fudan University, Shanghai, China.
| | - Kaihua Zhou
- Qingpu Branch of Zhongshan Hospital Affiliated to Fudan University, Shanghai, China
| | - Nong Chen
- Qingpu Branch of Zhongshan Hospital Affiliated to Fudan University, Shanghai, China
| |
Collapse
|
5
|
Salameh M, Fram B. The synthes femoral neck system (FNS): a technical tip and case series. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:3373-3376. [PMID: 39073600 DOI: 10.1007/s00590-024-04053-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2024] [Accepted: 07/21/2024] [Indexed: 07/30/2024]
Abstract
The femoral neck system (FNS) was recently introduced for treatment of femoral neck fractures. A novel feature is an anti-rotation screw with a diverging design from the neck bolt to provide rotational stability. Using the 4 Nm torque limiting screwdriver might cause the incomplete insertion of the screw specifically in dense or sclerotic bone. A nontorque limiting manual screwdriver should be used to complete the insertion and locking of the screw to prevent this error. We present series of seven cases with incomplete insertion of the anti-rotation screw in patient with femoral neck fractures treated with the FNS.
Collapse
Affiliation(s)
- Motasem Salameh
- Department of Orthopedics, Yale University School of Medicine, 47 College Street 2nd Floor, New Haven, CT, 06510, USA
| | - Brianna Fram
- Department of Orthopedics, Yale University School of Medicine, 47 College Street 2nd Floor, New Haven, CT, 06510, USA.
| |
Collapse
|
6
|
Henze K, Vogel C, Wienhöfer L, Dudda M. [Management of the cut-out of various forms of osteosynthesis for proximal femoral fractures]. UNFALLCHIRURGIE (HEIDELBERG, GERMANY) 2024; 127:343-348. [PMID: 38466408 DOI: 10.1007/s00113-024-01420-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 01/31/2024] [Indexed: 03/13/2024]
Abstract
Proximal femoral fractures are a common type of injury in older people. A cut-out of the femoral neck screw after initial osteosynthetic surgery of proximal femoral fractures is a frequent and feared complication. There could be different causes for cut-outs. Osteoporosis and necrosis of the femoral head could be biological reasons for cut-outs; however, mechanical factors, such as reduction, implant position and morphological characteristics of fractures also have a major influence on the cut-out rate. The treatment of the cut-out is often complex and depends on the destruction of the femoral head and the acetabulum. If the bone quality is still good and the head is not completely destroyed, a reosteosynthesis can be performed. Conversion to an endoprosthetic replacement is often the only possibility. Endoprosthetic treatment is often complex and associated with a high morbidity.
Collapse
Affiliation(s)
- K Henze
- Zentrum für Muskuloskelettale Chirurgie, Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsmedizin Essen, Universität Duisburg-Essen, Hufelandstr. 55, 45147, Essen, Deutschland.
| | - C Vogel
- Zentrum für Muskuloskelettale Chirurgie, Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsmedizin Essen, Universität Duisburg-Essen, Hufelandstr. 55, 45147, Essen, Deutschland
| | - L Wienhöfer
- Zentrum für Muskuloskelettale Chirurgie, Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsmedizin Essen, Universität Duisburg-Essen, Hufelandstr. 55, 45147, Essen, Deutschland
| | - M Dudda
- Zentrum für Muskuloskelettale Chirurgie, Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsmedizin Essen, Universität Duisburg-Essen, Hufelandstr. 55, 45147, Essen, Deutschland
| |
Collapse
|
7
|
Guo C, Huang J, Chen Z, Cai Z, Cai T. Clinical efficacy of Femoral Neck System for treatment of unstable femoral neck fractures in young adults. J Int Med Res 2024; 52:3000605241238983. [PMID: 38729774 PMCID: PMC11089946 DOI: 10.1177/03000605241238983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/26/2024] [Indexed: 05/12/2024] Open
Abstract
OBJECTIVE This study was performed to evaluate the mid-term clinical efficacy of the Femoral Neck System (FNS) (DePuy Synthes, Zuchwil, Switzerland) in treating young patients with unstable Pauwels type III femoral neck fractures. METHODS We performed a retrospective observational analysis of 21 young adults treated with the FNS. Clinical outcomes were assessed based on fracture reduction quality, Harris hip scores, and postoperative complication rates. RESULTS The study comprised 21 patients with a mean age of 35 years (range, 20-50 years) who were followed for a mean duration of 22.8 months (range, 16-30 months). Closed reduction was unfeasible in three (14.3%) patients, each of whom required open reduction. Notable postoperative complications were avascular necrosis in two (9.5%) patients, nonunion in one (4.7%), and implant failure in one (4.7%). Each of these complications led to the requirement for total hip arthroplasty. CONCLUSION The favorable mid-term clinical outcomes of this study indicate that the FNS is a potentially effective treatment modality for young individuals with unstable Pauwels type III femoral neck fractures.
Collapse
Affiliation(s)
- ChangYong Guo
- Department of Orthopaedics, The 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - JiaPing Huang
- Department of Orthopaedics, The 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - ZhiBiao Chen
- Department of Orthopaedics, The 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - ZeMing Cai
- Department of Orthopaedics, The 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - TaoYi Cai
- Department of Orthopaedics, The 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| |
Collapse
|
8
|
Chung H, Kim Y, Kook I, Kwak JW, Hwang KT. Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study. Clin Orthop Surg 2024; 16:184-193. [PMID: 38562623 PMCID: PMC10973613 DOI: 10.4055/cios23190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 10/21/2023] [Accepted: 11/24/2023] [Indexed: 04/04/2024] Open
Abstract
Background Femoral neck fractures need to be treated in their early stages with accurate reduction and stable fixation to reduce complications. The authors compared the early radiologic outcomes of femoral neck fractures treated with the recently introduced Femoral Neck System (FNS, Depuy-Synthes) with conventional cannulated screws (CS) in a multicenter design. Furthermore, the factors associated with early failure after FNS were analyzed. Methods The FNS group included 40 patients treated between June 2019 and January 2020, and the CS group included 65 patients treated between January 2015 and May 2019. The operation was performed in 3 university hospitals. Patient demographics, fracture classification, postoperative reduction quality, sliding distance of FNS or CS, union and time to union, and complication rates were examined. Logistic regression analysis was performed on candidate factors for early failure of the FNS group. Results The FNS group had a 90% union rate and a mean time to union of 4.4 months, while the CS group had similar results with an 83.1% union rate and a mean time to union of 5.1 months. In the subgroup analysis of Pauwels type III fractures, the union rates were 75.0% and 58.8% in the FNS and CS groups, respectively, and the time to union was significantly shorter in the FNS group with 4.8 months compared to 6.8 months in the CS group. Early failure rate within 6 months of FNS fixation was observed to be 10%, which included 3 reduction failures and 1 excessive sliding with a broken implant. Risk factors for early failure after FNS were identified as displaced fractures (Garden classification type III or IV), poor reduction quality, longer tip-apex distance, greater sliding distance, and 1-hole implants, of which sliding distance was the only significant risk factor in multivariate analysis. Conclusions In femoral neck fractures, FNS and CS did not show significant differences for short-term radiologic results. FNS resulted in shorter operative time than cannulated screw fixation and favorable outcomes in Pauwels type III femoral neck fractures. The FNS could be considered a reliable and safe alternative to CS when treating femoral neck fractures.
Collapse
Affiliation(s)
- HoeJeong Chung
- Department of Orthopaedic Surgery, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Youngwoo Kim
- Department of Orthopaedic Surgery, Uijeongbu St. Mary’s Hospital, The Catholic University of Korea College of Medicine, Uijeongbu, Korea
| | - Incheol Kook
- Department of Orthopaedic Surgery, Hanyang University Hospital, Hanyang University College of Medicine, Seoul, Korea
| | - Ji Woong Kwak
- Department of Orthopaedic Surgery, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Kyu Tae Hwang
- Department of Orthopaedic Surgery, Hanyang University Hospital, Hanyang University College of Medicine, Seoul, Korea
| |
Collapse
|
9
|
Aerden LK, Geelen H, DE Wachter G. Revision ratio after Femoral Neck System implantation for hip fracture treatment: a retrospective cohort analysis. Acta Orthop Belg 2024; 90:5-10. [PMID: 38669642 DOI: 10.52628/90.1.11289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2024]
Abstract
The aim of the study is to determine the revision ratio after implantation of the femoral neck system (FNS) for the treatment of femoral neck fractures. A retrospective single center cohort analysis with a total of 71 patients who underwent the implantation of the FNS between December 2019 and December 2021, was performed. 31 males and 40 females were included. There was no exclusion based on BMI, ASA score, Garden classification or Pauwels classification. Primary outcome was the revision rate after FNS implantation. Secondary outcomes comprise the reason for revision surgery as well as the time toward revision surgery and the 30-day mortality. The revision ratio was 11 out of 71 patients (15.5%) with an average time to revision surgery of 10 months. Most common reason for revision was avascular necrosis (AVN) in 45.5%. Other reasons for revision surgery were implant failure due to a secondary fall on to the hip with the FNS implant in place, cut-out, cut-through and malunion in respectively 27.3%, 9%, 9% and 9% of the revision patients. The one- hole plate was used in 72% of the patients. Mean follow-up was 18.07 months (range 6-30 months). Full weight bearing instruction was given to 85.9% of the patients. Partial weight bearing in 14.1% of the patients. In conclusion, the FNS has similar revision ratio when used for femoral neck fractures compared to cannulated screw fixation in literature. The predominant reason for revision is AVN and implant failure with no difference between the use of the one- or-two-hole plate in this study.
Collapse
|
10
|
Mohammadzadehazarabadı J. Investigation of dynamic hip plate screw systems in different lengths with finite element analysis. Heliyon 2024; 10:e26302. [PMID: 38404799 PMCID: PMC10884520 DOI: 10.1016/j.heliyon.2024.e26302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 11/27/2023] [Accepted: 02/09/2024] [Indexed: 02/27/2024] Open
Abstract
Objectives Dynamic systems aim to create an environment that encourages bone healing while minimizing stress shielding, which is a phenomenon where the bone loses density due to a lack of stress during the healing process. In this study, it was aimed that the stress distributions on plates of different lengths in the dynamic hip plate screw system were investigated. Materials and methods In our study, the human proximal femur model (3-D) obtained from computerized tomography was transferred to Finite Element Analysis (FEA) computer simulation. Plates with 2-4-6 holes were placed on the knitted bone model. The models used in this study were mainly determined as five components: cortical-cancellous bone, lateral plate, cortical screws, and compression neck screws. A 1 mm intertrochanteric fracture area was created from the trochanter major region. Results When plates of different lengths were applied, there was no significant difference in the stress in the compression screw and the chamber it was located in.It shows that when a 2-hole plate is used, the stress will be high, especially between the lower cortical screw and the cortex. In these three groups, it was observed that the stress points were in at least 6-hole plates. Conclusion The results of this study showed that the shorter the plate applied, the greater the stress on the plate and cortical screws in the femur diaphysis.
Collapse
|
11
|
Liu G, Yang C, Wang R, Tang J, Wu H, Wei L, Hu J. Application of robot navigation system for insertion of femoral neck system in the treatment of femoral neck fracture. BMC Musculoskelet Disord 2024; 25:47. [PMID: 38200451 PMCID: PMC10777528 DOI: 10.1186/s12891-024-07172-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 01/04/2024] [Indexed: 01/12/2024] Open
Abstract
PURPOSE To evaluate the short-term clinical efficacy and advantages of surgery robot positioning system for insertion of Femoral Neck System (FNS) in the treatment of femoral neck fractures. METHODS The clinical data of 52 patients with Femoral neck fracture (FNF) who had been treated with FNS between June 2020 and September 2021 were retrospectively analyzed. Among them, 26 patients were treated with traditional FNS (control group), while 26 additional patients were treated with FNS assisted by an orthopaedic robot positioning system (study group). The operation duration, frequency of key-guide needle placement, intraoperative blood loss, incision length, fracture healing rate, fracture healing time, and the Harris scores at the last follow-up were calculated and compared between the 2 groups. RESULTS The study group had shorter operation duration, fewer numbers of placing the key-guide needle, less intraoperative blood loss, and smaller surgical incisions than the control group (all, P < 0.05). There was no significant difference in the rate of fracture healing rate between the 2 groups (P = 0.47), while the fracture healing duration of the study group was shorter than that of the control group (P = 0.03). At the last follow-up, compared with the control group, the Harris score and the number of excellent and good ratings were significantly higher in the study group (all, P < 0.05). CONCLUSIONS Using orthopaedic surgery robot positioning system-assisted FNS in the treatment of FNFs can effectively improve the efficiency of surgery, shorten operation time, and reduce the number of placing the key-guide needle, intraoperative blood loss, and operative trauma. Simultaneously, it shortens the duration of fracture healing and improves the recovery of hip function.
Collapse
Affiliation(s)
- Gang Liu
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China
| | - Chengzhi Yang
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China
| | - Renchong Wang
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China
| | - Jingli Tang
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China
| | - Hao Wu
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China
| | - Lu Wei
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China
| | - Juzheng Hu
- Department of Trauma Center, Liuzhou Worker's Hospital, The Fourth Affiliated Hospital of Guangxi Medical University, Guangxi, 545005, China.
| |
Collapse
|
12
|
Niemann M, Maleitzke T, Jahn M, Salmoukas K, Braun KF, Graef F, Stöckle U, Meller S. Restoration of Hip Geometry after Femoral Neck Fracture: A Comparison of the Femoral Neck System (FNS) and the Dynamic Hip Screw (DHS). Life (Basel) 2023; 13:2073. [PMID: 37895454 PMCID: PMC10608621 DOI: 10.3390/life13102073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/15/2023] [Accepted: 10/16/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND The femoral neck system (FNS) was introduced as a minimally invasive fixation device for managing femoral neck fractures. OBJECTIVE To compare radiographic, clinical, and patient-reported outcome measures (PROMs) of femoral neck fracture patients following FNS compared to dynamic hip screw (DHS) implantation combined with an anti-rotational screw. METHODS Patients who underwent closed reduction and internal fixation of a femoral neck fracture between 2020 and 2022 were retrospectively included. We measured leg length, femoral offset, and centrum-collum-diaphyseal (CCD) angle in plain radiographs. Scar length, Harris Hip Score, short-form health survey 36-item score (SF-36), and Numeric Rating Scale (NRS) were assessed during follow-up visits. RESULTS We included 43 patients (22 females) with a median age of 66 (IQR 57, 75). In both groups, leg length differences between the injured and the contralateral side increased, and femoral offset and CCD angle differences were maintained over time. FNS patients had shorter scars and reported fewer emotional problems and more energy. There were no differences between groups regarding the remaining SF-36 sub-scores, Harris Hip Score, and NRS. CONCLUSIONS The FNS allows for a comparable leg length, femoral offset, and CCD angle reconstruction while achieving similarly high functional and global health scores to the DHS.
Collapse
Affiliation(s)
- Marcel Niemann
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, 13353 Berlin, Germany
| | - Tazio Maleitzke
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, 13353 Berlin, Germany
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Clinician Scientist Programme, Anna-Louisa-Karsch-Straße 2, 10178 Berlin, Germany
| | - Markus Jahn
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
| | - Katharina Salmoukas
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
- Department of Trauma Surgery and Orthopaedics, BG Hospital Unfallkrankenhaus Berlin gGmbH, 12683 Berlin, Germany
| | - Karl F. Braun
- Department of Trauma Surgery, University Hospital Rechts der Isar, Technical University of Munich, 81675 München, Germany;
| | - Frank Graef
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
| | - Ulrich Stöckle
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
| | - Sebastian Meller
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, and Humboldt-Universität zu Berlin, Centre for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; (T.M.); (M.J.); (K.S.); (F.G.); (U.S.); (S.M.)
| |
Collapse
|
13
|
Kim HS, Yoo JH, Lee YK, Park JS, Won YY. Treatment of Femoral Neck Fractures in the Elderly: A Survey of the Korean Hip Society Surgeons. Hip Pelvis 2023; 35:157-163. [PMID: 37727295 PMCID: PMC10505840 DOI: 10.5371/hp.2023.35.3.157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/31/2023] [Accepted: 02/01/2023] [Indexed: 09/21/2023] Open
Abstract
Purpose This study examined the methods for treatment of femoral neck fracture (FNF) preferred by members of the Korean Hip Society (KHS) and identified factors that influence decisions regarding the surgical intervention of choice. Materials and Methods A total of 97 members of the KHS responded to the 16-question survey which included questions about the mean number of surgeries performed each month for treatment of femoral neck fractures, the cut-off age for deciding between internal fixation and arthroplasty, the implant used most often, usage of cement, and factors influencing each decision. Results The mean cut-off age used when deciding between internal fixation and arthroplasty was 64 years old. Hemiarthroplasty (HA) (70%) was the most preferred option for treatment of displaced FNFs in cases where arthroplasty was indicated (total hip arthroplasty [THA] 19% and dual mobility THA 11%). The main reasons for selection of arthroplasty over reduction with internal fixation were age and pre-fracture ambulatory status. Pre-trauma ambulatory status and/or sports activity were the main factors in selection of HA over THA. Cement was used by 33% of responders. Poor bone quality and a broad femoral canal were factors that influenced the usage of cement. Conclusion Management of FNFs in the elderly is a major health problem worldwide; thus, remaining alert to current trends in treatment is essential for surgeons. The mean cut-off age used in deciding between internal fixation and arthroplasty was 64 years old. HA is the preferred method for treatment of displaced FNFs for members of the KHS.
Collapse
Affiliation(s)
- Hong Seok Kim
- Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, Korea
| | - Je-Hyun Yoo
- Department of Orthropaedic Surgery, Hallym University Sacred Heart Hospital, Anyang, Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Jong-Seok Park
- Department of Orthopedic Surgery, Soonchunhyang University Hospital Cheonan, Cheonan, Korea
| | - Ye-Yeon Won
- Department of Orthopaedic Surgery, Ajou University Medical Center, Ajou University College of Medicine, Suwon, Korea
| |
Collapse
|
14
|
Stoffel K, Michelitsch C, Arora R, Babst R, Candrian C, Eickhoff A, Gebhard F, Platz A, Schmid FA, Weschenfelder W, Sommer C. Clinical performance of the Femoral Neck System within 1 year in 125 patients with acute femoral neck fractures, a prospective observational case series. Arch Orthop Trauma Surg 2023; 143:4155-4164. [PMID: 36460761 PMCID: PMC10293436 DOI: 10.1007/s00402-022-04686-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 10/27/2022] [Indexed: 12/03/2022]
Abstract
INTRODUCTION Osteosynthesis of femoral neck fractures (FNFs) is an important treatment option, especially for younger patients. We aimed to assess the rate of early implant-related complications in FNF osteosynthesis using the Femoral Neck System (FNS). PATIENTS AND METHODS Consecutive patients diagnosed with displaced or nondisplaced FNFs were treated with FNS in this prospective, observational, multicenter investigation. Patients were followed up for minimally 3 months and up to 12 months if radiologic bone union and no pain was not achieved beforehand. Predefined treatment-related adverse events (AEs, defined as implant failure, loss of reduction, iatrogenic fractures, deep infection, and surgical revision), radiologic bone union, and patient-reported Harris hip score (HHS) and EQ-5D-5L index score were assessed. RESULTS One hundred and twenty-five patients were included in the study. Thirty-eight (30.4%) fractures were displaced (Garden III and IV), and 37 (29.6%) were vertical fractures (Pauwels type III). Predefined treatment-related AE rate at 3 months was 8 patients, 6.4% (95% CI, 2.8-12.2), and at 12 months, 11 patients, 8.8% (95% CI, 4.5-15.2). Cumulative incidences of bone union were 68% at 3 months, 90% at 6 months, and 98% at 12 months. The mean changes of HHS and EQ-5D-5L index score between preinjury and at 12 months were -7.5 (95% CI, [ - 21.1] to [6.2]) and - 0.03 (95% CI, [ - 0.21] to [0.15]), respectively; neither were statistically significant. CONCLUSION The current study on osteosynthesis of FNFs with the FNS resulted in treatment-related complication rates of 6.4% (95% CI, 2.8-12.2) at 3 months and 8.8% (95% CI, 4.5-15.2) at 12 months. On average, patients returned to preinjury function and quality of life. The current study may also indicate that the conventional wisdom of treating stable FNF in patients aged between 60 and 80 years with osteosynthesis may need to be reconsidered. REGISTRATION The study is registered with ClinicalTrials.gov (registration number: NCT02422355).
Collapse
Affiliation(s)
- Karl Stoffel
- Department of Orthopaedics and Traumatology, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland.
| | | | - Rohit Arora
- Department for Orthopaedics Trauma Surgery, Medical University Innsbruck, Innsbruck, Austria
| | - Reto Babst
- Department of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland
- Department of Orthopedics and Trauma, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Christian Candrian
- Service of Orthopaedics and Traumatology, Department of Surgery, EOC, Lugano, Switzerland
| | - Alexander Eickhoff
- Department of Trauma Surgery, Hand, Plastic and Reconstructive Surgery, University of Ulm, Ulm, Germany
| | - Florian Gebhard
- Department of Trauma Surgery, Hand, Plastic and Reconstructive Surgery, University of Ulm, Ulm, Germany
| | - Andreas Platz
- Department of General, Hand, and Trauma Surgery, City Hospital Triemli, Zurich, Switzerland
| | - Florian Andreas Schmid
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Bruderholz, Switzerland
| | - Wolfram Weschenfelder
- Department of Trauma, Hand and Reconstructive Surgery, Friedrich-Schiller-University Jena, Jena, Germany
| | - Christoph Sommer
- Department of Surgery, Kantonsspital Graubuenden, Chur, Switzerland
| |
Collapse
|
15
|
Jiang Q, Liu Y, Bai X, Deng Y, Cao Y, Yu C, Song Q, Li Y. Nonanatomical reduction of femoral neck fractures in young patients treated with femoral neck system: a retrospective cohort study. BMC Musculoskelet Disord 2023; 24:412. [PMID: 37226140 PMCID: PMC10207767 DOI: 10.1186/s12891-023-06551-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 05/19/2023] [Indexed: 05/26/2023] Open
Abstract
PURPOSE Negative buttress reduction should be avoided in the treatment of femoral neck fractures (FNFs) using conventional fixation. As the femoral neck system (FNS) has been recently developed and utilized widely to treat FNFs, the association of reduction quality with postoperative complications and clinical function has not been clarified. The purpose of this study was to evaluate the clinical effect of nonanatomical reduction in young patients with FNFs treated with FNS. METHODS This multicenter, retrospective cohort study included 58 patients with FNFs treated with FNS between September 2019 and December 2021. According to the reduction quality immediately following surgery, patients were classified into positive, anatomical, and negative buttress reduction groups. Postoperative complications were assessed with 12 months of follow-up. The logistic regression model was used to identify risk factors for postoperative complications. The postoperative hip function was assessed using the Harris hip scores (HHS) system. RESULTS At a follow-up of 12 months, a total of eight patients (8/58, 13.8%) had postoperative complications in three groups. Compared with the anatomical reduction group, negative buttress reduction was significantly associated with a higher complication rate (OR = 2.99, 95%CI 1.10-8.10, P = 0.03). No significant associations were found between positive buttress reduction and the incidence of postoperative complications (OR = 1.21, 95%CI 0.35-4.14, P = 0.76). The difference was not statistically significant in Harris hip scores. CONCLUSION Negative buttress reduction should be avoided in young patients with FNFs treated with FNS.
Collapse
Affiliation(s)
- Qilong Jiang
- Department of Orthopaedic Surgery, Chongqing Orthopedic Hospital of Traditional Chinese Medicine, Chongqing, China
| | - Yang Liu
- Department of Orthopaedic Surgery, Chongqing Orthopedic Hospital of Traditional Chinese Medicine, Chongqing, China
| | - Xinwen Bai
- Department of Orthopaedic Surgery, Chongqing Orthopedic Hospital of Traditional Chinese Medicine, Chongqing, China
| | - Yu Deng
- Department of Orthopaedic Surgery, Chongqing Orthopedic Hospital of Traditional Chinese Medicine, Chongqing, China
| | - Yong Cao
- Department of Orthopaedic Surgery, Chongqing Orthopedic Hospital of Traditional Chinese Medicine, Chongqing, China
| | - Chengxiang Yu
- Department of Orthopaedic Surgery, Chongqing Sanbo Changan Hospital, Chongqing, China
| | - Qizhi Song
- Central Sterile Supply Department, Chonggang General Hospital, No. 1, Dayan Sancun, Dadukou District, Chongqing, 400010, China
| | - Yan Li
- Central Sterile Supply Department, Chonggang General Hospital, No. 1, Dayan Sancun, Dadukou District, Chongqing, 400010, China.
| |
Collapse
|
16
|
Survivability of the Femoral Neck System for the treatment of femoral neck fractures in adults. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023:10.1007/s00590-023-03474-5. [PMID: 36645494 DOI: 10.1007/s00590-023-03474-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 01/09/2023] [Indexed: 01/17/2023]
Abstract
INTRODUCTION Hip fractures are common injuries in the elderly, with an incidence that continues to rise. The femoral neck system (FNS) recently emerged as a novel treatment option for femoral neck fractures, but long-term survivability of the implant remains uncertain. The purpose of this study is to evaluate survivability of the FNS and assess risk factors for implant failure. METHODS One hundred five adult patients who received the FNS (DePuy Synthes, Raynham, MA) for femoral neck fractures (AO/OTA 31B) were included. Surgeries were performed within a regional hospital system comprising 18 facilities. All patients had a minimum follow-up of 1 year. The primary outcome measures were cumulative incidence of implant failure and 1-year mortality, including risk factor analysis. RESULTS Twelve implants failed at a follow-up ranging from 17 days to 8 months, and 7 failed within 90 days. Cumulative incidence of implant failure was 2% at 30 days, 7% at 90 days, 12% at 6 months, and 13% at 1 year. Causes of implant failure included cut-out (n = 5), non-union (n = 4), peri-implant fracture (n = 2), and avascular necrosis (n = 1). Univariate Cox regression identified Pauwels type III fractures and an increasing AP Parker ratio as significant risk factors for failure. Pauwels type III fractures showed a 5.48 times higher risk compared to Pauwels types I & II. Every 10% increase in AP Parker ratio increased risk of failure by 2.39 times. The 1-year mortality rate was 21%, and univariate logistic regression identified age as the only risk factor (odds ratio = 3.71). CONCLUSIONS The incidence of implant failure and 1-year mortality rate in this study suggests that the FNS can provide reliable fixation compared to rates in the literature, but complications are not uncommon. Avoiding Pauwels type III fractures and optimizing implant placement appear crucial to preventing implant failure. LEVEL OF EVIDENCE Therapeutic Level IV.
Collapse
|