Sander KL, Warren SE, Mendel LL. Survey of selective electrode deactivation attitudes and practices by cochlear implant audiologists. Cochlear Implants Int 2023; 24:167-175. [PMID: 36732065 DOI: 10.1080/14670100.2023.2166571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES The purpose of this study was to explore clinician attitudes regarding selective electrode deactivation and to investigate the primary methodology used to identify poorly encoded electrodes, deactivate identified electrodes, and measure outcomes. METHODS An online survey consisting of 32 questions was administered to certified clinical and research cochlear implant (CI) audiologists. Questions asked participants about their demographic information, device programming patterns, and attitudes regarding selective electrode deactivation. RESULTS Fifty-four audiologists completed the survey. When asked whether they believed selectively deactivating poorly encoded electrodes could improve speech perception outcomes, 43% of respondents selected 'Probably Yes,' 39% selected 'Definitely Yes,' and 18% selected 'Might or Might Not.' Of those who reported deactivating electrodes as part of CI programming, various methodology was reported to identify and deactivate poorly encoding electrodes and evaluate effectiveness of deactivation. General reasons against deactivation were also reported. DISCUSSION CI audiologists generally believed selective electrode deactivation could be used to improve speech perception outcomes for patients; however, few reported implementing selective electrode deactivation in practice. Among those who do perform selective electrode deactivation, the reported methodology was highly variable. CONCLUSION These findings support the need for clinical practice guidelines to assist audiologists in performing selective electrode deactivation.
Collapse
Affiliation(s)
- Kara L Sander
- Department of Communication Sciences and Disorders, University of Memphis, Memphis, TN, USA
| | - Sarah E Warren
- Department of Communication Sciences and Disorders, University of Memphis, Memphis, TN, USA
| | - Lisa Lucks Mendel
- Department of Communication Sciences and Disorders, University of Memphis, Memphis, TN, USA
| |
Collapse
|
2
|
Warren SE, Atcherson SR. Evaluation of a clinical method for selective electrode deactivation in cochlear implant programming. Front Hum Neurosci 2023; 17:1157673. [PMID: 37063101 PMCID: PMC10101326 DOI: 10.3389/fnhum.2023.1157673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/09/2023] [Indexed: 03/31/2023] Open
Abstract
BackgroundCochlear implants are a neural prosthesis used to restore the perception of hearing in individuals with severe-to-profound hearing loss by stimulating the auditory nerve with electrical current through a surgically implanted electrode array. The integrity of the interface between the implanted electrode array and the auditory nerve contributes to the variability in outcomes experienced by cochlear implant users. Strategies to identify and eliminate poorly encoding electrodes have been found to be effective in improving outcomes with the device, but application is limited in a clinical setting.ObjectiveThe purpose of this study was to evaluate a clinical method used to identify and selectively deactivate cochlear implants (CI) electrodes related to poor electrode-neural interface.MethodsThirteen adult CI users participated in a pitch ranking task to identify indiscriminate electrode pairs. Electrodes associated with indiscriminate pairs were selectively deactivated, creating an individualized experimental program. Speech perception was evaluated in the baseline condition and with the experimental program before and after an acclimation period. Participant preference responses were recorded at each visit.ResultsStatistically significant improvements using the experimental program were found in at least one measure of speech perception at the individual level in four out of 13 participants when tested before acclimation. Following an acclimation period, ten out of 13 participants demonstrated statistically significant improvements in at least one measure of speech perception. Statistically significant improvements were found with the experimental program at the group level for both monosyllabic words (p = 0.006) and sentences in noise (p = 0.020). Additionally, ten participants preferred the experimental program prior to the acclimation period and eleven preferred the experimental program following the acclimation period.ConclusionResults from this study suggest that electrode deactivation may yield improvement in speech perception following an acclimation period. A majority of CI users in our study reported a preference for the experimental program. This method proved to be a suitable clinical strategy for identifying and deactivating poorly encoding electrodes in adult CI users.
Collapse
Affiliation(s)
- Sarah E. Warren
- Cochlear Implant Research Laboratory, School of Communication Sciences and Disorders, University of Memphis, Memphis, TN, United States
- Department of Audiology, Arkansas Children’s Hospital, Little Rock, AR, United States
- Department of Audiology and Speech Pathology, University of Arkansas for Medical Sciences, Little Rock, AR, United States
- *Correspondence: Sarah E. Warren,
| | - Samuel R. Atcherson
- Department of Audiology and Speech Pathology, University of Arkansas for Medical Sciences, Little Rock, AR, United States
- Department of Otolaryngology–Head and Neck Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, United States
| |
Collapse
|
3
|
Inoue T, Tona Y, Okano T, Omori K, Yamamoto N. Detection of Tip Fold-Over of the Slim Modiolar Electrode Using Intraoperative Mobile Cone-Beam Computed Tomography. Otolaryngol Head Neck Surg 2023. [PMID: 36939567 DOI: 10.1002/ohn.240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/17/2022] [Accepted: 12/10/2022] [Indexed: 01/26/2023]
Abstract
OBJECTIVE This study aimed to evaluate the importance of mobile cone-beam computed tomography in detecting tip fold-over of a slim modiolar electrode within the cochlea during surgery. STUDY DESIGN Retrospective case review. SETTING Tertiary medical center. METHODS From January 2020 to June 2022, 33 ears of 30 patients with normal cochlear morphology underwent cochlear implantation with slim modiolar electrodes and intraoperative mobile cone-beam computed tomography imaging. Furthermore, we retrospectively reviewed the medical records and images. RESULTS The tip fold-over of the electrodes was detected using mobile cone-beam computed tomography in 3 out of 33 ears (9.1%). We could not identify the tip fold-over by scouting plain X-ray images in 2 out of 3 cases before taking the cone-beam computed tomography images. Electrode removal and reinsertion were performed before wound closure and the successful reinsertion was confirmed by mobile cone-beam computed tomography. The folded electrode tips were located at 238.8°, 152°, and 185.8°. CONCLUSION Intraoperative mobile cone-beam computed tomography is useful in detecting the tip fold-over of the slim modiolar electrodes during surgery. Therefore, it was possible to reinsert the electrodes in all cases before closing the wound, eliminating the need for revision surgeries. Moreover, the analysis of mobile cone-beam computed tomography images may help to elucidate the mechanisms of electrode tip fold-over.
Collapse
Affiliation(s)
- Taishi Inoue
- Department of Otolaryngology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan
| | - Yosuke Tona
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takayuki Okano
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Koichi Omori
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Norio Yamamoto
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.,Department of Otolaryngology, Kobe City Medical Center General Hospital, Kobe, Hyogo, Japan
| |
Collapse
|
4
|
Danieli F, Hyppolito MA, Hussain R, Hoen M, Karoui C, Reis ACMB. The Effects of Multi-Mode Monophasic Stimulation with Capacitive Discharge on the Facial Nerve Stimulation Reduction in Young Children with Cochlear Implants: Intraoperative Recordings. J Clin Med 2023; 12:jcm12020534. [PMID: 36675460 PMCID: PMC9863587 DOI: 10.3390/jcm12020534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 12/28/2022] [Accepted: 01/05/2023] [Indexed: 01/11/2023] Open
Abstract
Facial nerve stimulation (FNS) is a potential complication which may affect the auditory performance of children with cochlear implants (CIs). We carried out an exploratory prospective observational study to investigate the effects of the electrical stimulation pattern on FNS reduction in young children with CI. Ten ears of seven prelingually deafened children with ages up to 6 years old who undergone a unilateral or bilateral CI surgery were included in this study. Electromyographic (EMG) action potentials from orbicularis oculi muscle were recorded using monopolar biphasic stimulation (ST1) and multi-mode monophasic stimulation with capacitive discharge (ST2). Presence of EMG responses, facial nerve stimulation thresholds (T-FNS) and EMG amplitudes were compared between ST1 and ST2. Intra-cochlear electrodes placement, cochlear-nerve and electrode-nerve distances were also estimated to investigate their effects on EMG responses. The use of ST2 significantly reduced the presence of intraoperative EMG responses compared to ST1. Higher stimulation levels were required to elicit FNS with ST2, with smaller amplitudes, compared to ST1. No and weak correlation was observed between cochlea-nerve and electrode-nerve distances and EMG responses, respectively. ST2 may reduce FNS in young children with CI. Differently from the electrical stimulation pattern, the cochlea-nerve and electrode-nerve distances seem to have limited effects on FNS in this population.
Collapse
Affiliation(s)
- Fabiana Danieli
- Postgraduate Program at the Department of Health Sciences, RCS, Ribeirão Preto Medical School, University of São Paulo, Bandeirantes 3900, Ribeirão Preto 14049-900, Brazil
- Clinical Department, Oticon Medical, Lino de Moraes Leme 883, São Paulo 04360-001, Brazil
- Correspondence:
| | - Miguel Angelo Hyppolito
- Department of Ophthalmology, Otorhinolaryngology, Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Bandeirantes 3900, Ribeirão Preto 14049-900, Brazil
| | - Raabid Hussain
- Research & Technology Department, Oticon Medical, 2765 Smørum, Denmark
| | - Michel Hoen
- Clinical Evidence Department, Oticon Medical, 2720 Chem de Saint-Bernard, 06220 Vallauris, France
| | - Chadlia Karoui
- Clinical Evidence Department, Oticon Medical, 2720 Chem de Saint-Bernard, 06220 Vallauris, France
| | - Ana Cláudia Mirândola Barbosa Reis
- Department of Health Sciences, RCS, Ribeirão Preto Medical School, University of São Paulo, Bandeirantes 3900, Ribeirão Preto 14049-900, Brazil
| |
Collapse
|
5
|
Hyppolito MA, Barbosa Reis ACM, Danieli F, Hussain R, Le Goff N. Cochlear re-implantation with the use of multi-mode grounding associated with anodic monophasic pulses to manage abnormal facial nerve stimulation. Cochlear Implants Int 2022:1-10. [PMID: 36583989 DOI: 10.1080/14670100.2022.2157077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Objectives: To investigate the outcomes of cochlear re-implantation using multi-mode grounding stimulation associated with anodic monophasic pulses to manage abnormal facial nerve stimulation (AFNS) in cochlear implant (CI) recipients. Methods: Retrospective case report. An adult CI recipient with severe AFNS and decrease in auditory performance was re-implanted with a new CI device to change the pulse shape and stimulation mode. Patient's speech perception scores and AFNS were compared before and after cochlear re-implantation, using monopolar stimulation associated with cathodic biphasic pulses and multi-mode stimulation mode associated to anodic monophasic pulses, respectively. The insertion depth angle and the electrode-nerve distances were also investigated, before and after cochlear re-implantation. Results: AFNS was resolved, and the speech recognition scores rapidly increased in the first year after cochlear re-implantation while remaining stable. After cochlear re-implantation, the e15 and e20 electrodes showed shorter electrode-nerve distances compared to their correspondent e4 and e7 electrodes, which induced AFNS in the first implantation. Conclusions: Cochlear re-implantation with multi-mode grounding stimulation associated with anodic monophasic pulses was an effective strategy for managing AFNS. The patient's speech perception scores rapidly improved and AFNS was not detected four years after cochlear re-implantation.
Collapse
Affiliation(s)
- Miguel Angelo Hyppolito
- Department of Ophthalmology, Otorhinolaryngology, Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil
| | | | - Fabiana Danieli
- Department of Health Sciences, RCS, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil.,Clinical Department, Oticon Medical, São Paulo, Brazil
| | - Raabid Hussain
- Research & Technology Department, Oticon Medical, Smorum, Denmark
| | - Nicolas Le Goff
- Clinical Research Department, Oticon Medical, Smorum, Denmark
| |
Collapse
|
6
|
Image-Guided Cochlear Implant Programming: A Systematic Review and Meta-analysis. Otol Neurotol 2022; 43:e924-e935. [PMID: 35973035 DOI: 10.1097/mao.0000000000003653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE To review studies evaluating clinically implemented image-guided cochlear implant programing (IGCIP) and to determine its effect on cochlear implant (CI) performance. DATA SOURCES PubMed, EMBASE, and Google Scholar were searched for English language publications from inception to August 1, 2021. STUDY SELECTION Included studies prospectively compared intraindividual CI performance between an image-guided experimental map and a patient's preferred traditional map. Non-English studies, cadaveric studies, and studies where imaging did not directly inform programming were excluded. DATA EXTRACTION Seven studies were identified for review, and five reported comparable components of audiological testing and follow-up times appropriate for meta-analysis. Demographic, speech, spectral modulation, pitch accuracy, and quality-of-life survey data were collected. Aggregate data were used when individual data were unavailable. DATA SYNTHESIS Audiological test outcomes were evaluated as standardized mean change (95% confidence interval) using random-effects meta-analysis with raw score standardization. Improvements in speech and quality-of-life measures using the IGCIP map demonstrated nominal effect sizes: consonant-nucleus-consonant words, 0.15 (-0.12 to 0.42); AzBio quiet, 0.09 (-0.05 to 0.22); AzBio +10 dB signal-noise ratio, 0.14 (-0.01 to 0.30); Bamford-Kowel-Bench sentence in noise, -0.11 (-0.35 to 0.12); Abbreviated Profile of Hearing Aid Benefit, -0.14 (-0.28 to 0.00); and Speech Spatial and Qualities of Hearing Scale, 0.13 (-0.02 to 0.28). Nevertheless, 79% of patients allowed to keep their IGCIP map opted for continued use after the investigational period. CONCLUSION IGCIP has potential to precisely guide CI programming. Nominal effect sizes for objective outcome measures fail to reflect subjective benefits fully given discordance with the percentage of patients who prefer to maintain their IGCIP map.
Collapse
|
7
|
Misplaced Cochlear Implant Electrodes Outside the Cochlea: A Literature Review and Presentation of Radiological and Electrophysiological Findings. Otol Neurotol 2022; 43:567-579. [PMID: 35261380 DOI: 10.1097/mao.0000000000003523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
HYPOTHESIS It is possible to detect when misplacement and malposition of the cochlear implant (CI) electrode array has occurred intraoperatively through different investigations. We aim to explore the literature surrounding cochlear implant misplacements and share our personal experience with such cases to formulate a quick-reference guide that may be able to help cochlear implant teams detect misplacements early. BACKGROUND Misplacement and malposition of a cochlear implant array can lead to poor hearing outcomes. Where misplacements go undetected during the primary surgery, patients may undergo further surgery to replace the implant array into the correct intracochlear position. METHODS Systematic literature review on cochlear implant misplacements and malpositions and a retrospective review of our program's cases in over 6,000 CI procedures. RESULTS Twenty-nine cases of CI misplacements are reported in the English literature. Sixteen cases of cochlear implant misplacements are reported from our institution with a rate of 0.28%. A further 12 cases of intracochlear malpositions are presented. The electrophysiological (CI electrically evoked auditory brainstem response, transimpedance matrix) and radiological (X-ray and computed tomography scan) findings from our experience are displayed in a tabulated quick-reference guide to show the possible characteristics of misplaced and malpositioned cochlear implant electrode arrays. CONCLUSION Both intraoperative electrophysiological and radiological tests can show when the array has been misplaced or if there is an intracochlear malposition, to prompt timely intra-operative reinsertion to yield better outcomes for patients.
Collapse
|
8
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|