1
|
Alqahtani MM, Willowson KP, Constable C, Fulton R, Kench PL. Optimization of
99m
Tc whole‐body SPECT/CT image quality: A phantom study. J Appl Clin Med Phys 2022; 23:e13528. [PMID: 35049129 PMCID: PMC8992937 DOI: 10.1002/acm2.13528] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 12/13/2021] [Accepted: 12/17/2021] [Indexed: 11/10/2022] Open
Affiliation(s)
- Mansour M. Alqahtani
- Faculty of Medicine and Health University of Sydney Sydney Australia
- Department of Radiological sciences College of Applied Medical Science Najran University Najran Saudi Arabia
| | - Kathy P. Willowson
- Department of Nuclear Medicine Royal North Shore Hospital Sydney Australia
- Institute of Medical Physics Faculty of Science The University of Sydney Sydney Australia
| | - Chris Constable
- Faculty of Medicine and Health University of Sydney Sydney Australia
- HERMES Medical Solutions, Strandbergsgatan 16 Stockholm Sweden
| | - Roger Fulton
- Faculty of Medicine and Health University of Sydney Sydney Australia
- Department of Medical Physics Westmead Hospital Sydney Australia
| | - Peter L. Kench
- Faculty of Medicine and Health University of Sydney Sydney Australia
| |
Collapse
|
2
|
Zhang R, Wang M, Zhou Y, Wang S, Shen Y, Li N, Wang P, Tan J, Meng Z, Jia Q. Impacts of acquisition and reconstruction parameters on the absolute technetium quantification of the cadmium-zinc-telluride-based SPECT/CT system: a phantom study. EJNMMI Phys 2021; 8:66. [PMID: 34568990 PMCID: PMC8473509 DOI: 10.1186/s40658-021-00412-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 09/10/2021] [Indexed: 02/06/2023] Open
Abstract
Background The digital cadmium–zinc–telluride (CZT)-based SPECT system has many advantages, including better spatial and energy resolution. However, the impacts of different acquisition and reconstruction parameters on CZT SPECT quantification might still need to be validated. This study aimed to evaluate the impacts of acquisition parameters (the main energy window and acquisition time per frame) and reconstruction parameters (the number of iterations, subsets in iterative reconstruction, post-filter, and image correction methods) on the technetium quantification of CZT SPECT/CT. Methods A phantom (PET NEMA/IEC image quality, USA) was filled with four target-to-background (T/B) ratios (32:1, 16:1, 8:1, and 4:1) of technetium. Mean uptake values (the calculated mean concentrations for spheres) were measured to evaluate the recovery coefficient (RC) changes under different acquisition and reconstruction parameters. The corresponding standard deviations of mean uptake values were also measured to evaluate the quantification error. Image quality was evaluated using the National Electrical Manufacturers Association (NEMA) NU 2–2012 standard. Results For all T/B ratios, significant correlations were found between iterations and RCs (r = 0.62–0.96 for 1–35 iterations, r = 0.94–0.99 for 35–90 iterations) as well as between the full width at half maximum (FWHM) of the Gaussian filter and RCs (r = − 0.86 to − 1.00, all P values < 0.05). The regression coefficients of 1–35 iterations were higher than those of 35–90 iterations (0.51–1.60 vs. 0.02–0.19). RCs calculated with AC (attenuation correction) + SC (scatter correction) + RR (resolution recovery correction) combination were more accurate (53.82–106.70%) than those calculated with other combinations (all P values < 0.05). No significant statistical differences (all P values > 0.05) were found between the 15% and 20% energy windows except for the 32:1 T/B ratio (P value = 0.023) or between the 10 s/frame and 120 s/frame acquisition times except for the 4:1 T/B ratio (P value = 0.015) in terms of RCs. Conclusions CZT-SPECT/CT of technetium resulted in good quantification accuracy. The favourable acquisition parameters might be a 15% energy window and 40 s/frame of acquisition time. The favourable reconstruction parameters might be 35 iterations, 20 subsets, the AC + SC + RR correction combination, and no filter. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00412-4.
Collapse
Affiliation(s)
- Ruyi Zhang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Miao Wang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Yaqian Zhou
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Shen Wang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Yiming Shen
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Ning Li
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Peng Wang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Jian Tan
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Zhaowei Meng
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
| | - Qiang Jia
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
| |
Collapse
|