1
|
Asari M, Takahashi Y, Namba R, Hoshina C, Mori K, Okuda K, Shimizu K. Second- and third-degree kinship analysis by NGS-based SNP genotyping and evaluation of 2045-SNP performance on limited or degraded DNA. Forensic Sci Int 2024; 367:112346. [PMID: 39708709 DOI: 10.1016/j.forsciint.2024.112346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Revised: 08/30/2024] [Accepted: 12/09/2024] [Indexed: 12/23/2024]
Abstract
We developed a novel next-generation sequencing-based single-nucleotide polymorphism (SNP) genotyping method for second- and third-degree kinship analysis, and designed 1144- and 2045-SNP panels using one (Set A) and two sets (Sets A and B) of primers. These SNP loci were analyzed in 120 Japanese individuals, and likelihood ratios (LRs) for kinship discrimination were calculated to evaluate the effect of number of SNP loci in simulated analysis. Likelihood evaluation was performed using DNA profiles from two individuals, namely, the unknown and one reference relative. Genotyping of the 1144 and 2045 SNPs was informative to discriminate aunt-nephew/niece as second-degree relatives and unrelated pairs. In third-degree relationship analysis, distributions of log10LRs between the unknown and a first cousin (FC) were not separated from those of unrelated individuals even in 2045-SNP genotyping. To perform enhanced discrimination of third-degree relationships, we also evaluated the effectiveness of DNA profiles from three individuals, namely, the unknown and two first cousins (2FC). A likelihood evaluation from the 2045 SNPs using 2FC was more useful than the use of FC. Our method was applied to 12 kinship cases for second- and third-degree relationship analysis, and LRs from 1144- and 2045-SNP genotypes were markedly higher than those from conventional short tandem repeat profiles. Moreover, we evaluated the performance of the 2045 SNPs using limited or degraded DNA, compared with that with a larger amount of DNA. Using 0.1 ng of non-degraded DNA, the average concordance was higher than 97 %. In analysis with heavily degraded DNA (degradation index=32.2), we also detected high concordance (85.5 %) from 2045-SNP genotypes, compared with the lower rate (52.4 %) from 21 short tandem repeat profiles. Our method should be highly sensitive with discriminatory DNA profiles for analyzing second- and third-degree relationships.
Collapse
Affiliation(s)
- Masaru Asari
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan.
| | - Yuta Takahashi
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan
| | - Ryo Namba
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan
| | - Chisato Hoshina
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan
| | - Kanae Mori
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan
| | - Katsuhiro Okuda
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan
| | - Keiko Shimizu
- Department of Legal Medicine, Asahikawa Medical University, Asahikawa, Japan
| |
Collapse
|
2
|
Pedroza Matute S, Iyavoo S. Applications and Performance of Precision ID GlobalFiler NGS STR, Identity, and Ancestry Panels in Forensic Genetics. Genes (Basel) 2024; 15:1133. [PMID: 39336724 PMCID: PMC11431077 DOI: 10.3390/genes15091133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Revised: 08/19/2024] [Accepted: 08/23/2024] [Indexed: 09/30/2024] Open
Abstract
Short Tandem Repeat (STR) testing via capillary electrophoresis is undoubtedly the most popular forensic genetic testing method. However, its low multiplexing capabilities and limited performance with challenging samples are among the factors pushing scientists towards new technologies. Next-generation sequencing (NGS) methods overcome some of these limitations while also enabling the testing of Single-Nucleotide Polymorphisms (SNPs). Nonetheless, these methods are still under optimization, and their adoption into practice is limited. Among the available kits, Thermo Fisher Scientific (Waltham, MA, USA) produces three Precision ID Panels: GlobalFiler NGS STR, Identity, and Ancestry. A clear review of these kits, providing information useful for the promotion of their use, is, however, lacking. To close the gap, a literature review was performed to investigate the popularity, applications, and performance of these kits. Following the PRISMA guidelines, 89 publications produced since 2015 were identified. China was the most active country in the field, and the Identity Panel was the most researched. All kits appeared robust and useful for low-quality and low-quantity samples, while performance with mixtures varied. The need for more population data was highlighted, as well as further research surrounding variables affecting the quality of the sequencing results.
Collapse
Affiliation(s)
- Sharlize Pedroza Matute
- School of Natural Sciences, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
- AttoGroup Limited, Scottow Enterprise Park, Badersfield, Norwich NR10 5FB, UK
| | - Sasitaran Iyavoo
- School of Natural Sciences, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
- AttoGroup Limited, Scottow Enterprise Park, Badersfield, Norwich NR10 5FB, UK
| |
Collapse
|
3
|
Pedroza Matute S, Turvey K, Iyavoo S. Advancing human genotyping: The Infinium HTS iSelect Custom microarray panel (Rita) development study. Forensic Sci Int Genet 2024; 71:103049. [PMID: 38653142 DOI: 10.1016/j.fsigen.2024.103049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 04/04/2024] [Accepted: 04/15/2024] [Indexed: 04/25/2024]
Abstract
Single Nucleotide Polymorphisms (SNPs), as the most prevalent type of variation in the human genome, play a pivotal role in influencing human traits. They are extensively utilized in diverse fields such as population genetics, forensic science, and genetic medicine. This study focuses on the 'Rita' BeadChip, a custom SNP microarray panel developed using Illumina Infinium HTS technology. Designed for high-throughput genotyping, the panel facilitates the analysis of over 4000 markers efficiently and cost-effectively. After careful clustering performed on a set of 1000 samples, an evaluation of the Rita panel was undertaken, assessing its sensitivity, repeatability, reproducibility, precision, accuracy, and resistance to contamination. The panel's performance was evaluated in various scenarios, including sex estimation and parental relationship assessment, using GenomeStudio data analysis software. Findings show that over 95 % of the custom BeadChip assay markers were successful, with better performance of transitions over other mutations, and a considerably lower success rate for Y chromosome loci. An exceptional call rate exceeding 99 % was demonstrated for control samples, even with DNA input as low as 0.781 ng. Call rates above 80 % were still obtained with DNA quantities under 0.1 ng, indicating high sensitivity and suitability for forensic applications where DNA quantity is often limited. Repeatability, reproducibility, and precision studies revealed consistency of the panel's performance across different batches and operators, with no significant deviations in call rates or genotyping results. Accuracy assessments, involving comparison with multiple available genetic databases, including the 1000 Genome Project and HapMap, denoted over 99 % concordance, establishing the Rita panel's reliability in genotyping. The contamination study revealed insights into background noise and allowed the definition of thresholds for sample quality evaluation. Multiple metrics for differentiating between negative controls and true samples were highlighted, increasing the reliability of the obtained results. The sex estimation tool in GenomeStudio proved highly effective, correctly assigning sex in all samples with autosomal loci call rates above 97 %. The parental relationship assessment of family trios highlighted the utility of GenomeStudio in identifying genotyping errors or potential Mendelian inconsistencies, promoting the application of arrays such as Rita in kinship testing. Overall, this evaluation confirms the Rita microarray as a robust, high-throughput genotyping tool, underscoring its potential in genetic research and forensic applications. With its custom content and adaptable design, it not only meets current genotyping demands but also opens avenues for further research and application expansion in the field of genetic analysis.
Collapse
Affiliation(s)
| | - Kiera Turvey
- IDna Genetics Limited, Scottow Enterprise Park, Norwich, Norfolk NR10 5FB, United Kingdom
| | - Sasitaran Iyavoo
- IDna Genetics Limited, Scottow Enterprise Park, Norwich, Norfolk NR10 5FB, United Kingdom; School of Chemistry, College of Health and Science, University of Lincoln, Lincoln, Lincolnshire LN6 7TS, United Kingdom.
| |
Collapse
|
4
|
Guo F, Liu Z, Long G, Zhang B, Liu D, Yu S. Performance and characterization of 94 identity-informative SNPs in Northern Han Chinese using ForenSeq ™ DNA signature prep kit. J Forensic Leg Med 2024; 103:102678. [PMID: 38522119 DOI: 10.1016/j.jflm.2024.102678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 03/05/2024] [Accepted: 03/17/2024] [Indexed: 03/26/2024]
Abstract
Target and flanking region (FR) variation at 94 identity-informative SNPs (iSNPs) are investigated in 635 Northern Han Chinese using the ForenSeq DNA Signature Prep Kit on the MiSeq FGx Forensic Genomics System. The dataset presents the following performance characteristics (average values): ≥60% bases with a quality score of 20 or higher (%≥ Q20); >700 × of depth of coverage (DoC) from both Sample Details Reports and Flanking Region Reports; >80% of effective reads; ≥60% of allele coverage ratio (ACR); and ≥70% of inter-locus balance, while some stable low-performance characteristics are also observed: low DoC at rs1736442, rs1031825, rs7041158, rs338882, rs2920816, rs1493232, rs719366, and rs2342747; high noise at rs891700; and imbalanced ACR at rs6955448 and rs338882. The average amplicon length is 69 bp, suitable for detecting degraded samples. Bioinformatic concordance achieves 99.99% between the ForenSeq Universal Analysis Software (UAS) and the Integrative Genomic Viewer (IGV) inspection. Discordance results from flanking region deletions of rs10776839, rs8078417, rs2831700, and rs1454361. Due to FR variants within amplicons detected by massively parallel sequencing (MPS), the increases in the number of unique alleles, effective alleles (Ae), and observed heterozygosity (Hobs) are 46.81%, 4.51%, and 3.29%, respectively. Twelve FR variants are first reported to dbSNP, such as rs1252699848, rs1665500714, rs1771121532, rs2097285015, rs1851671415, rs2045669877, rs2046758811, rs2044248635, rs1251308240, rs1968822112, rs1981638299, and rs1341756746. All 94 iSNPs from target and amplicon data are in Hardy-Weinberg equilibrium (HWE) and independent within autosomes. As expected, forensic parameters from the amplicon data increase significantly on the combined power of discrimination (CPD = 1 - 3.9876 × 10-38) and the combined power of exclusion (CPE = 1 - 6.6690 × 10-8). Additionally, the power of the system effectiveness (CPD = 1 - 6.7054 × 10-72 and CPE = 1 - 4.4719 × 10-20) with sequence-based 27 autosomal STRs and 94 iSNP amplicons in combination is substantially improved compared to one type of marker alone. In conclusion, we have established a traditional length-based and current sequence-based reference database with 58 STRs and 94 iSNPs in the Northern Han Chinese population. We hope these data can serve as a solid reference and foundation for forensic practice.
Collapse
Affiliation(s)
- Fei Guo
- Shenyang Medical College, Shenyang, Liaoning, 110034, PR China; Key Laboratory of Human Ethnic Specificity and Phenomics of Critical Illness in Liaoning Province, Shenyang, Liaoning, 110034, PR China; Key Laboratory of Phenomics in Shenyang City, Shenyang, Liaoning, 110034, PR China.
| | - Ze Liu
- DNA Laboratory of Forensic Science Center, Shenyang Public Security Bureau, Shenyang, Liaoning, 110002, PR China
| | - Guannan Long
- DNA Laboratory of Forensic Science Center, Shenyang Public Security Bureau, Shenyang, Liaoning, 110002, PR China
| | - Biao Zhang
- DNA Laboratory of Forensic Science Center, Shenyang Public Security Bureau, Shenyang, Liaoning, 110002, PR China
| | - Dahua Liu
- Department of Forensic Medicine, Jinzhou Medical University, Jinzhou, Liaoning, 121001, PR China
| | - Shaobo Yu
- DNA Laboratory of Forensic Science Center, Shenyang Public Security Bureau, Shenyang, Liaoning, 110002, PR China.
| |
Collapse
|