Chae J, Nguyen TT, Oh SY. Quantification of saccadic fatigability and diagnostic efficacy for myasthenia gravis.
J Neurol 2024;
271:5035-5045. [PMID:
38796801 DOI:
10.1007/s00415-024-12461-7]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 05/15/2024] [Accepted: 05/16/2024] [Indexed: 05/29/2024]
Abstract
BACKGROUND AND OBJECTIVES
The diagnostic challenge of myasthenia gravis (MG) is exacerbated by the variable efficacy of current testing methodologies, necessitating innovative approaches to accurately identify the condition. This study aimed to assess ocular muscle fatigue in patients with MG using video-oculography (VOG) by examining repetitive saccadic eye movements and comparing these metrics to those of healthy control participants.
METHODS
This prospective, cross-sectional study was conducted at a tertiary care center and involved 62 patients diagnosed with MG (48 with ocular MG and 14 with generalized MG) and a control group of 31 healthy individuals, matched for age and sex. The assessment involved recording saccadic eye movements within a ± 15° range, both horizontally and vertically, at a rate of 15 saccades per minute over a 5-min period, resulting in 75 cycles. Participants were afforded a 3-min rest interval between each set to mitigate cumulative fatigue. The primary outcome was the detection of oculomotor fatigue, assessed through changes in saccadic waveforms, range, peak velocity, latency, and the duration from onset to target, with a focus on comparing the second saccade against the average of the last five saccades.
RESULTS
In the evaluation of repetitive saccadic movements, patients with MG exhibited a reduced saccadic range and a prolonged duration to reach the target, compared to healthy subjects. Furthermore, a significant elevation in the frequency of multistep saccades was observed among MG patients, with a marked rise observed over consecutive trials. Receiver operating characteristic (ROC) analysis revealed the discriminative performance of multistep saccade frequency, in conjunction with variations in saccadic range and duration from onset to target achievement between the second saccade and the mean of the final five saccades, as effective in distinguishing MG patients from healthy subjects. Although alterations in peak saccadic velocity and latency were less pronounced, they were nevertheless detectable.
DISCUSSION
The utilization of VOG for repetitive saccadic testing in the diagnosis of MG has demonstrated considerable diagnostic precision. This methodology affords significant accuracy in evaluating ocular muscle fatigue in MG patients, providing class III evidence supportive of its clinical application.
Collapse