1
|
Feng L, Pierscionek B, Weeber H, Canovas Vidal C, Rozema JJ. The Effect of the Zonular Fiber Angle of Insertion on Accommodation. Vision (Basel) 2024; 8:45. [PMID: 39189183 PMCID: PMC11348028 DOI: 10.3390/vision8030045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/11/2024] [Accepted: 07/18/2024] [Indexed: 08/28/2024] Open
Abstract
Purpose: With age, there is an anterior shift of the ciliary body in the eye, which alters the angle of zonular insertion in older eyes compared with younger eyes. This study aims to simulate lens accommodation with different zonular angles to consider the influence of zonular position on lens accommodative capacity. Methods: Models were constructed based on lenses aged 11, 29, and 45 years using a 2D axisymmetric structure that included a capsule, cortex, nucleus, and zonular fibers. The different zonular fibers were simulated by changing the position of the point where the zonular fibers connect to the ciliary body. The effect of the different zonular fiber insertion angles on the model shape and optical power was analyzed. Results: The models show that smaller angles made by zonular fibers to the surface of the lens lead to larger optical power changes with simulated stretching. When the models were stretched, and when varying the zonule angles, the optical power of the 11-, 29-, and 45-year-old models changed up to 0.17 D, 0.24 D, and 0.30 D, respectively. The effect of zonular angles on the anterior radius of curvature of the anterior surface varied by 0.29 mm, 0.23 mm, and 0.25 mm for the 11-, 29-, and 45-year-old models, respectively. Conclusions: Larger zonular fiber insertion angles cause smaller deformation and less accommodative change, while parallel zonules induce the largest change in lens shape.
Collapse
Affiliation(s)
- Liying Feng
- Johnson & Johnson Surgical Vision, 9728 NX Groningen, The Netherlands; (H.W.); (C.C.V.)
- Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, 2000 Antwerp, Belgium
| | - Barbara Pierscionek
- Faculty of Health Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Chelmsford CM1 1SQ, UK;
| | - Henk Weeber
- Johnson & Johnson Surgical Vision, 9728 NX Groningen, The Netherlands; (H.W.); (C.C.V.)
| | - Carmen Canovas Vidal
- Johnson & Johnson Surgical Vision, 9728 NX Groningen, The Netherlands; (H.W.); (C.C.V.)
| | - Jos J. Rozema
- Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, 2000 Antwerp, Belgium
- Department of Ophthalmology, Antwerp University Hospital, 2650 Edegem, Belgium
| |
Collapse
|
2
|
Ameku KA, Berggren CC, Pedrigi RM. Implantation of a capsular tension ring during cataract surgery attenuates predicted remodeling of the post-surgical lens capsule along the visual axis. Front Bioeng Biotechnol 2024; 11:1300830. [PMID: 38312508 PMCID: PMC10834774 DOI: 10.3389/fbioe.2023.1300830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 12/26/2023] [Indexed: 02/06/2024] Open
Abstract
Introduction: Cataract surgery permanently alters the mechanical environment of the lens capsule by placing a hole in the anterior portion and implanting an intraocular lens (IOL) that has a very different geometry from the native lens. We hypothesized that implant configuration and mechanical interactions with the post-surgical lens capsule play a key role in determining long-term fibrotic remodeling. Methods: We developed the first finite element-growth and remodeling (FE-G&R) model of the post-surgical lens capsule to evaluate how implantation of an IOL with and without a capsular tension ring (CTR) impacted evolving lens capsule mechanics and associated fibrosis over time after cataract surgery. Results: Our models predicted that implantation of a CTR with the IOL into the post-surgical lens capsule reduced the mechanical perturbation, thickening, and stiffening along the visual axis in both the remnant anterior and posterior portions compared to implantation of the IOL alone. Discussion: These findings align with patient studies and suggest that implantation of a CTR with the IOL during routine cataract surgery would attenuate the incidence of visually-debilitating capsule fibrosis. Our work demonstrates that use of such modeling techniques has substantial potential to aid in the design of better surgical strategies and implants.
Collapse
Affiliation(s)
| | | | - Ryan M. Pedrigi
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE, United States
| |
Collapse
|
3
|
Characterisation and Modelling of an Artificial Lens Capsule Mimicking Accommodation of Human Eyes. Polymers (Basel) 2021; 13:polym13223916. [PMID: 34833214 PMCID: PMC8619262 DOI: 10.3390/polym13223916] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 10/29/2021] [Accepted: 11/03/2021] [Indexed: 11/17/2022] Open
Abstract
A synthetic material of silicone rubber was used to construct an artificial lens capsule (ALC) in order to replicate the biomechanical behaviour of human lens capsule. The silicone rubber was characterised by monotonic and cyclic mechanical tests to reveal its hyper-elastic behaviour under uniaxial tension and simple shear as well as the rate independence. A hyper-elastic constitutive model was calibrated by the testing data and incorporated into finite element analysis (FEA). An experimental setup to simulate eye focusing (accommodation) of ALC was performed to validate the FEA model by evaluating the shape change and reaction force. The characterisation and modelling approach provided an insight into the intrinsic behaviour of materials, addressing the inflating pressure and effective stretch of ALC under the focusing process. The proposed methodology offers a virtual testing environment mimicking human capsules for the variability of dimension and stiffness, which will facilitate the verification of new ophthalmic prototype such as accommodating intraocular lenses (AIOLs).
Collapse
|
4
|
Michael R, D'Antin JC, Pinilla Cortés L, Burd HJ, Sheil B, Barraquer RI. Deformations and Ruptures in Human Lenses With Cortical Cataract Subjected to Ex Vivo Simulated Accommodation. Invest Ophthalmol Vis Sci 2021; 62:12. [PMID: 33427852 PMCID: PMC7804572 DOI: 10.1167/iovs.62.1.12] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Human cortical opacities are most commonly accompanied by changes in lens fiber structure in the equatorial region at the lens nucleus–cortex interface. Cortex and nucleus have different elastic properties, which change with age. We therefore subjected ex vivo lenses to simulated accommodation and studied the internal deformations to better understand the mechanism of cortical cataract formation. Methods Nine human donor lenses (33–88 years old) were tested using a bespoke radial stretching device for anterior eye segments. Seven of the lenses exhibited cortical cataracts. The other two lenses, without cataract, were used as controls. Frontal and cross-sectional images of the lens obtained during stretching facilitated measurements on equatorial lens diameter and central lens thickness in the stretched and unstretched states. Results Stretching caused the lens equatorial diameter to increase in all cases. Conversely, the lens central thickness showed no systematic variation during stretching. For four of the lenses with cortical cataract, ruptures were observed during stretching at the nucleus–cortex boundary adjacent to the cortical cataracts. Ruptures were not observed in the control lenses or in the three other lenses with cortical cataract. Conclusions Internal ruptures can occur in aged ex vivo lenses subjected to simulated disaccommodation. These ruptures occur at the nucleus–cortex interface; at this location, a significant stiffness discontinuity is expected to develop with age. It is hypothesized that ruptures occur in in vivo lenses during accommodation—or attempted accommodation.
Collapse
Affiliation(s)
- Ralph Michael
- Centro de Oftalmología Barraquer, Barcelona, Spain.,Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain.,University Eye Clinic, Paracelsus Medical University, Salzburg, Austria
| | - Justin Christopher D'Antin
- Centro de Oftalmología Barraquer, Barcelona, Spain.,Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Laura Pinilla Cortés
- Centro de Oftalmología Barraquer, Barcelona, Spain.,Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Harvey John Burd
- Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Brian Sheil
- Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Rafael I Barraquer
- Centro de Oftalmología Barraquer, Barcelona, Spain.,Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain.,Universitat Internacional de Catalunya, Barcelona, Spain
| |
Collapse
|
5
|
Bilbao-Calabuig R, Gónzalez-López F, Llovet-Rausell A, Ortega-Usobiaga J, Tejerina Fernández V, Llovet-Osuna F. Lens-based surgical correction of presbyopia. Where are we in 2020? ACTA ACUST UNITED AC 2020; 96:74-88. [PMID: 32868085 DOI: 10.1016/j.oftal.2020.07.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 07/19/2020] [Accepted: 07/20/2020] [Indexed: 01/06/2023]
Abstract
INTRODUCTION Presbyopia is the progressive and irreversible loss of accommodation due to aging. It is one of the main causes of loss of quality of life in people from 45 years of age, due to the, often novel, dependence on spectacles. The eagerness to correct it by ophthalmologists impulsed by the desire of millions of people who suffer from it, has become one of the main drivers for the development of intraocular lens (IOL) technology over the last twenty years. MATERIAL AND METHODS This review briefly presents the different alternatives that have allowed us to improve the crystalline lens surgical approach of presbyopia; from monofocal lenses and monovision technique, accommodative, refractive, and diffractive multifocal lenses, and finally the most recent extended depth of focus/field lenses known as EDOFs. RESULTS Each IOL has its advantages, limitations and disadvantages. Furthermore, there is no single lens that suits the needs of all patients. CONCLUSIONS It is necessary to know the variety of lenses available, and to have an in-depth understanding of their optical properties, as well as the impact that these will have later on their clinical performance and on the visual quality of the patients. This should help us to select the best alternative for each of them.
Collapse
Affiliation(s)
- R Bilbao-Calabuig
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España.
| | - F Gónzalez-López
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España
| | - A Llovet-Rausell
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Valencia, España; Servicio Oftalmología, Hospital Universitario La Fe, Valencia, España
| | - J Ortega-Usobiaga
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Bilbao, España
| | - V Tejerina Fernández
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España
| | - F Llovet-Osuna
- Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Madrid, España; Unidad de Cirugía Refractiva y Cataratas, Clínica Baviera-Aier Hospital Eye Group, Valencia, España
| |
Collapse
|
6
|
Wang K, Pierscionek BK. Biomechanics of the human lens and accommodative system: Functional relevance to physiological states. Prog Retin Eye Res 2019; 71:114-131. [DOI: 10.1016/j.preteyeres.2018.11.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 09/24/2018] [Accepted: 11/07/2018] [Indexed: 12/28/2022]
|
7
|
Wolffsohn JS, Davies LN. Presbyopia: Effectiveness of correction strategies. Prog Retin Eye Res 2018; 68:124-143. [PMID: 30244049 DOI: 10.1016/j.preteyeres.2018.09.004] [Citation(s) in RCA: 148] [Impact Index Per Article: 24.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 09/14/2018] [Accepted: 09/18/2018] [Indexed: 01/04/2023]
Abstract
Presbyopia is a global problem affecting over a billion people worldwide. The prevalence of unmanaged presbyopia is as high as 50% of those over 50 years of age in developing world populations, due to a lack of awareness and accessibility to affordable treatment, and is even as high as 34% in developed countries. Definitions of presbyopia are inconsistent and varied, so we propose a redefinition that states "presbyopia occurs when the physiologically normal age-related reduction in the eye's focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual's requirements". Strategies for correcting presbyopia include separate optical devices located in front of the visual system (reading glasses) or a change in the direction of gaze to view through optical zones of different optical powers (bifocal, trifocal or progressive addition spectacle lenses), monovision (with contact lenses, intraocular lenses, laser refractive surgery and corneal collagen shrinkage), simultaneous images (with contact lenses, intraocular lenses and corneal inlays), pinhole depth of focus expansion (with intraocular lenses, corneal inlays and pharmaceuticals), crystalline lens softening (with lasers or pharmaceuticals) or restored dynamics (with 'accommodating' intraocular lenses, scleral expansion techniques and ciliary muscle electrostimulation); these strategies may be applied differently to the two eyes to optimise the range of clear focus for an individual's task requirements and minimise adverse visual effects. However, none fully overcome presbyopia in all patients. While the restoration of natural accommodation or an equivalent remains elusive, guidance is given on presbyopic correction evaluation techniques.
Collapse
Affiliation(s)
- James S Wolffsohn
- Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, B4 7ET, UK.
| | - Leon N Davies
- Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, B4 7ET, UK
| |
Collapse
|
8
|
The importance of parameter choice in modelling dynamics of the eye lens. Sci Rep 2017; 7:16688. [PMID: 29192148 PMCID: PMC5709469 DOI: 10.1038/s41598-017-16854-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Accepted: 11/18/2017] [Indexed: 11/08/2022] Open
Abstract
The lens provides refractive power to the eye and is capable of altering ocular focus in response to visual demand. This capacity diminishes with age. Current biomedical technologies, which seek to design an implant lens capable of replicating the function of the biological lens, are unable as yet to provide such an implant with the requisite optical quality or ability to change the focussing power of the eye. This is because the mechanism of altering focus, termed accommodation, is not fully understood and seemingly conflicting theories require experimental support which is difficult to obtain from the living eye. This investigation presents finite element models of the eye lens based on data from human lenses aged 16 and 35 years that consider the influence of various modelling parameters, including material properties, a wide range of angles of force application and capsular thickness. Results from axisymmetric models show that the anterior and posterior zonules may have a greater impact on shape change than the equatorial zonule and that choice of capsular thickness values can influence the results from modelled simulations.
Collapse
|