1
|
Janicijevic D, Saez-Berlanga A, Babiloni-Lopez C, Martin-Rivera F, Jiménez-Martínez P, Silvestre-Herrero A, Martínez-Puente J, Ferradás-Nogueira P, Juesas A, Gene-Morales J, Chulvi-Medrano I, Colado JC. Acute physiological and psychological responses during an incremental treadmill test wearing a new upper-body sports garment with elastomeric technology. Front Physiol 2024; 15:1372020. [PMID: 38711952 PMCID: PMC11070584 DOI: 10.3389/fphys.2024.1372020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 03/18/2024] [Indexed: 05/08/2024] Open
Abstract
Background: The use of elastomeric technology in sports garments is increasing in popularity; however, its specific impact on physiological and psychological variables is not fully understood. Thus, we aimed to analyze the physiological (muscle activation of the pectoralis major, triceps brachii, anterior deltoid, and rectus abdominis, capillary blood lactate, systolic and diastolic blood pressure, and heart rate) and psychological (global and respiratory rating of perceived exertion [RPE]) responses during an incremental treadmill test wearing a new sports garment for the upper body that incorporates elastomeric technology or a placebo garment. Methods: Eighteen physically active young adults participated in two randomized sessions, one wearing the elastomeric garment and the other wearing a placebo. Participants performed in both sessions the same treadmill incremental test (i.e., starting at 8 km/h, an increase of 2 km/h each stage, stage duration of 3 min, and inclination of 1%; the test ended after completing the 18 km/h Stage or participant volitional exhaustion). The dependent variables were assessed before, during, and/or after the test. Nonparametric tests evaluated differences. Results: The elastomeric garment led to a greater muscle activation (p < 0.05) in the pectoralis major at 16 km/h (+33.35%, p = 0.01, d = 0.47) and 18 km/h (+32.09%, p = 0.02, d = 0.55) and in the triceps brachii at 10 km/h (+20.28%, p = 0.01, d = 0.41) and 12 km/h (+34.95%, p = 0.04, d = 0.28). Additionally, lower lactate was observed at the end of the test (-7.81%, p = 0.01, d = 0.68) and after 5 min of recovery (-13.71%, p < 0.001, d = 1.00) with the elastomeric garment. Nonsignificant differences between the garments were encountered in the time to exhaustion, cardiovascular responses, or ratings of perceived exertion. Conclusion: These findings suggest that elastomeric garments enhance physiological responses (muscle activation and blood lactate) during an incremental treadmill test without impairing physical performance or effort perception.
Collapse
Affiliation(s)
- Danica Janicijevic
- Faculty of Sports Science, Ningbo University, Ningbo, China
- Department of Radiology, Ningbo No. 2 Hospital, Ningbo, China
- Department of Sports Sciences and Physical Conditioning, Faculty of Education, Universidad Catolica de la Santísima Concepción, Concepción, Chile
| | - Angel Saez-Berlanga
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Carlos Babiloni-Lopez
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Fernando Martin-Rivera
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Pablo Jiménez-Martínez
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
- ICEN Institute, Madrid, Spain
| | - Alejandro Silvestre-Herrero
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Javier Martínez-Puente
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Pablo Ferradás-Nogueira
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Alvaro Juesas
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Javier Gene-Morales
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Iván Chulvi-Medrano
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Juan C. Colado
- Research Group in Prevention and Health in Exercise and Sport (PHES), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| |
Collapse
|
2
|
DiFrancisco-Donoghue J, Borges K, Li T, Ballone O, Zwibel H, Douris PC. Reducing thrombotic risks in video gamers: investigating the benefits of walking and compression sleeves on blood hemodynamics. Am J Physiol Heart Circ Physiol 2024; 326:H538-H547. [PMID: 38133616 PMCID: PMC11221800 DOI: 10.1152/ajpheart.00669.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 12/07/2023] [Accepted: 12/21/2023] [Indexed: 12/23/2023]
Abstract
With the growing popularity of video gaming, deep vein thromboses are increasingly being reported in gamers. This study aimed to compare the effects of lower leg graduated compression sleeves and a 6-min walking break during prolonged gaming on blood flow and hemodynamics in competitive sport players to help mitigate this risk. Ten healthy gamers (19.6 ± 1.2 yr old; 9 men) consented to participate in this mixed-model crossover design study that consisted of three visits. In visit 1, participants engaged in continuous 2-h video game play wearing no compression (continuous). Visits 2 and 3 involved 2-h play wearing compression sleeves (compression) and 2-h game play interrupted at 1 h by a 6-min walk (walk). Doppler ultrasound measurements of the left popliteal artery were taken at 30, 60, 90, and 120 min, to record vessel diameter, blood flow velocity, and blood flow volume. Participants completed a survey to assess their perception of each approach. There was a significant interaction between conditions for blood flow and blood velocity (P = 0.01, P < 0.001). Post hoc analysis demonstrated a greater decrease in blood flow and blood velocity in the continuous group compared with the walk group at the 90-min mark (P = 0.04, P = 0.01). No differences were found between the compression and walk groups or between the continuous and compression groups (P = 0.42, P = 0.69). No interactions were observed in diameter, mean arterial pressure, or heart rate. This study suggests that incorporating a 6-min walk every 60 min during prolonged gaming is advisable to counteract the negative effects on blood flow hemodynamics.NEW & NOTEWORTHY A 6-min light-intensity walking break during gaming can effectively combat the adverse effects of prolonged sitting, surpassing compression garments. Prolonged sitting reduces blood flow velocity, potentially leading to deep vein thrombosis (DVT). Compression sleeves help, with superior results after a 6-min walk at 60 min. Although compression stockings offer moderate improvements, a 6-min active break proves more effective. These findings offer promising interventions for gamers' health, initiating guidelines to mitigate DVT risk during gaming.
Collapse
Affiliation(s)
- Joanne DiFrancisco-Donoghue
- Department of Osteopathic Medicine, New York Institute of Technology College of Osteopathic Medicine, Old Westbury, New York, United States
- Center for Esports Medicine, New York Institute of Technology, Old Westbury, New York, United States
| | - Kelly Borges
- Medical School, New York Institute of Technology College of Osteopathic Medicine, Old Westbury, New York, United States
| | - Timothy Li
- Medical School, New York Institute of Technology College of Osteopathic Medicine, Old Westbury, New York, United States
| | - Olivia Ballone
- Medical School, New York Institute of Technology College of Osteopathic Medicine, Old Westbury, New York, United States
| | - Hallie Zwibel
- Department of Family Medicine, New York Institute of Technology College of Osteopathic Medicine, Old Westbury, New York, United States
- Center for Esports Medicine, New York Institute of Technology, Old Westbury, New York, United States
| | - Peter C Douris
- Department of Physical Therapy, New York Institute of Technology, Old Westbury, New York, United States
| |
Collapse
|
3
|
Do Sports Compression Garments Alter Measures of Peripheral Blood Flow? A Systematic Review with Meta-Analysis. Sports Med 2023; 53:481-501. [PMID: 36622554 DOI: 10.1007/s40279-022-01774-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/01/2022] [Indexed: 01/10/2023]
Abstract
BACKGROUND One of the proposed mechanisms underlying the benefits of sports compression garments may be alterations in peripheral blood flow. OBJECTIVE We aimed to determine if sports compression garments alter measures of peripheral blood flow at rest, as well as during, immediately after and in recovery from a physiological challenge (i.e. exercise or an orthostatic challenge). METHODS We conducted a systematic literature search of databases including Scopus, SPORTDiscus and PubMed/MEDLINE. The criteria for inclusion of studies were: (1) original papers in English and a peer-reviewed journal; (2) assessed effect of compression garments on a measure of peripheral blood flow at rest and/or before, during or after a physiological challenge; (3) participants were healthy and without cardiovascular or metabolic disorders; and (4) a study population including athletes and physically active or healthy participants. The PEDro scale was used to assess the methodological quality of the included studies. A random-effects meta-analysis model was used. Changes in blood flow were quantified by standardised mean difference (SMD) [± 95% confidence interval (CI)]. RESULTS Of the 899 articles identified, 22 studies were included for the meta-analysis. The results indicated sports compression garments improve overall peripheral blood flow (SMD = 0.32, 95% CI 0.13, 0.51, p = 0.001), venous blood flow (SMD = 0.37, 95% CI 0.14, 0.60, p = 0.002) and arterial blood flow (SMD = 0.30, 95% CI 0.01, 0.59, p = 0.04). At rest, sports compression garments did not improve peripheral blood flow (SMD = 0.18, 95% CI - 0.02, 0.39, p = 0.08). However, subgroup analyses revealed sports compression garments enhance venous (SMD = 0.31 95% CI 0.02, 0.60, p = 0.03), but not arterial (SMD = 0.12, 95% CI - 0.16, 0.40, p = 0.16), blood flow. During a physiological challenge, peripheral blood flow was improved (SMD = 0.44, 95% CI 0.19, 0.69, p = 0.0007), with subgroup analyses revealing sports compression garments enhance venous (SMD = 0.48, 95% CI 0.11, 0.85, p = 0.01) and arterial blood flow (SMD = 0.44, 95% CI 0.03, 0.86, p = 0.04). At immediately after a physiological challenge, there were no changes in peripheral blood flow (SMD = - 0.04, 95% CI - 0.43, 0.34, p = 0.82) or subgroup analyses of venous (SMD = - 0.41, 95% CI - 1.32, 0.47, p = 0.35) and arterial (SMD = 0.12, 95% CI - 0.26, 0.51, p = 0.53) blood flow. In recovery, sports compression garments did not improve peripheral blood flow (SMD = 0.25, 95% CI - 0.45, 0.95, p = 0.49). The subgroup analyses showed enhanced venous (SMD = 0.67, 95% CI 0.17, 1.17, p = 0.009), but not arterial blood flow (SMD = 0.02, 95% CI - 1.06, 1.09, p = 0.98). CONCLUSIONS Use of sports compression garments enhances venous blood flow at rest, during and in recovery from, but not immediately after, a physiological challenge. Compression-induced changes in arterial blood flow were only evident during a physiological challenge.
Collapse
|
4
|
Effects of an external pneumatic compression device vs static compression garment on peripheral circulation and markers of sports performance and recovery. Eur J Appl Physiol 2022; 122:1709-1722. [PMID: 35475921 DOI: 10.1007/s00421-022-04953-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Accepted: 04/08/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE To identify the effects of a single 30 min partial lower leg external pneumatic compression (EPC) treatment compared to a static compression (SC) garment or a no treatment control (CTL) on markers of recovery and performance following a muscle damaging protocol. METHODS Thirty healthy, active males (23 ± 3 years; 180.2 ± 9.0 cm; 81.6 ± 11.3 kg) performed 100 drop jumps from a 0.6 m box followed by a randomized, single 30 min treatment of either a partial lower leg EPC device worn below the knee and above the ankle (110 mmHg), SC garment (20-30 mmHg) covering the foot and calf just below the knee, or no treatment CTL, and then returned 24 and 48 h later. Participants were assessed for measures of muscle soreness, fatigue, hemodynamics, blood lactate, muscle thickness, circumferences, and performance assessments. RESULTS The drop jump protocol significantly increased muscle soreness (p < 0.001), fatigue (p < 0.001), blood flow (p < 0.001), hemoglobin (p < 0.001), and muscle oxygen saturation (SMO2; p < 0.001). Countermovement jump and squat jump testing completed after treatment with either EPC, SC, or CTL revealed no differences for jump height between any condition. However, EPC treatment maintained consistent braking force and propulsive power measures across all timepoints for countermovement jump testing. EPC and SC treatment also led to better maintenance of squat jump performance for average relative propulsive force and power variables at 24 and 48 h compared to CTL. CONCLUSIONS A single 30 min partial leg EPC treatment may lead to more consistent jump performance following a damaging bout of exercise.
Collapse
|
5
|
Putting the Squeeze on Compression Garments: Current Evidence and Recommendations for Future Research: A Systematic Scoping Review. Sports Med 2021; 52:1141-1160. [PMID: 34870801 PMCID: PMC9023423 DOI: 10.1007/s40279-021-01604-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/12/2021] [Indexed: 11/30/2022]
Abstract
Background Compression garments are regularly worn during exercise to improve physical performance, mitigate fatigue responses, and enhance recovery. However, evidence for their efficacy is varied and the methodological approaches and outcome measures used within the scientific literature are diverse. Objectives The aim of this scoping review is to provide a comprehensive overview of the effects of compression garments on commonly assessed outcome measures in response to exercise, including: performance, biomechanical, neuromuscular, cardiovascular, cardiorespiratory, muscle damage, thermoregulatory, and perceptual responses. Methods A systematic search of electronic databases (PubMed, SPORTDiscus, Web of Science and CINAHL Complete) was performed from the earliest record to 27 December, 2020. Results In total, 183 studies were identified for qualitative analysis with the following breakdown: performance and muscle function outcomes: 115 studies (63%), biomechanical and neuromuscular: 59 (32%), blood and saliva markers: 85 (46%), cardiovascular: 76 (42%), cardiorespiratory: 39 (21%), thermoregulatory: 19 (10%) and perceptual: 98 (54%). Approximately 85% (n = 156) of studies were published between 2010 and 2020. Conclusions Evidence is equivocal as to whether garments improve physical performance, with little evidence supporting improvements in kinetic or kinematic outcomes. Compression likely reduces muscle oscillatory properties and has a positive effect on sensorimotor systems. Findings suggest potential increases in arterial blood flow; however, it is unlikely that compression garments meaningfully change metabolic responses, blood pressure, heart rate, and cardiorespiratory measures. Compression garments increase localised skin temperature and may reduce perceptions of muscle soreness and pain following exercise; however, rating of perceived exertion during exercise is likely unchanged. It is unlikely that compression garments negatively influence exercise-related outcomes. Future research should assess wearer belief in compression garments, report pressure ranges at multiple sites as well as garment material, and finally examine individual responses and varying compression coverage areas. Supplementary Information The online version contains supplementary material available at 10.1007/s40279-021-01604-9.
Collapse
|
6
|
O'Riordan SF, McGregor R, Halson SL, Bishop DJ, Broatch JR. Sports compression garments improve resting markers of venous return and muscle blood flow in male basketball players. JOURNAL OF SPORT AND HEALTH SCIENCE 2021:S2095-2546(21)00092-2. [PMID: 34314879 PMCID: PMC10362518 DOI: 10.1016/j.jshs.2021.07.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/10/2021] [Accepted: 06/21/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND The benefits associated with sports compression garments are thought to be closely related to enhanced blood flow. However, findings are equivocal, possibly due to heterogeneity in the techniques used for measuring blood flow, the garment types used, and the pressures applied. This study combined Doppler ultrasound and near-infrared spectroscopy technologies to provide the first comprehensive assessment of the effects of 3 sports compression garment types on markers of venous return and muscle blood flow at rest. METHODS Resting lower-limb blood flow measures (markers of venous return, muscle blood flow, and muscle oxygenation) of 22 elite, junior, male basketball players (age = 17.2 ± 0.9 years, mean ± SD) were assessed in 4 separate conditions: no compression (CON), compression tights (TIGHTS), compression shorts (SHORTS), and compression socks (SOCKS). Markers of venous return (cross-sectional area, time-averaged mean and peak blood flow velocity, and venous blood flow) were measured via Doppler ultrasound at the popliteal and common femoral veins. Muscle blood flow and muscle oxygenation were measured in the gastrocnemius medialis and vastus lateralis using near-infrared spectroscopy. RESULTS Popliteal markers of venous return were higher in TIGHTS compared to CON (p < 0.01) and SHORTS (p < 0.01), with SOCKS values higher compared with CON (p < 0.05). Common femoral vein markers of venous return were higher for all conditions compared to CON (p < 0.05), with TIGHTS values also higher compared to SOCKS (p < 0.05). Gastrocnemius medialis blood flow was higher for TIGHTS compared to CON (p = 0.000), SOCKS (p = 0.012), and SHORTS (p = 0.000), with SOCKS higher compared to SHORTS (p = 0.046). Vastus lateralis blood flow was higher for TIGHTS compared to CON (p = 0.028) and SOCKS (p = 0.019), with SHORTS also higher compared to CON (p = 0.012) and SOCKS (p = 0.005). Gastrocnemius medialis oxygenation was higher for TIGHTS compared to CON (p = 0.003), SOCKS (p = 0.033), and SHORTS (p = 0.003), with SOCKS higher compared to CON (p = 0.044) and SHORTS (p = 0.032). Vastus lateralis oxygenation was higher for TIGHTS compared to CON (p = 0.020) and SOCKS (p = 0.006). CONCLUSION Markers of venous return, muscle blood flow, and muscle oxygenation are increased with sports compression garments. TIGHTS are most effective, potentially because of the larger body area compressed.
Collapse
Affiliation(s)
- Shane F O'Riordan
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia; Department of Physiology, Australian Institute of Sport, Bruce, ACT 2617, Australia.
| | - Rod McGregor
- Faculty of Health, University of Canberra, Bruce, ACT 2617, Australia
| | - Shona L Halson
- School of Behavioural and Health Sciences, Australian Catholic University, Banyo, QLD 4014, Australia
| | - David J Bishop
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia
| | - James R Broatch
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia; Department of Physiology, Australian Institute of Sport, Bruce, ACT 2617, Australia
| |
Collapse
|
7
|
Lee DCW, Ali A, Sheridan S, Chan DKC, Wong SHS. Wearing Compression Garment Enhances Central Hemodynamics? A Systematic Review and Meta-Analysis. J Strength Cond Res 2020; 36:2349-2359. [PMID: 33065703 DOI: 10.1519/jsc.0000000000003801] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Lee, DCW, Ali, A, Sheridan, S, Chan, DKC, and Wong, SHS. Wearing compression garment enhances central hemodynamics? a systematic review and meta-analysis . J Strength Cond Res XX(X): 000-000, 2020-Compression garments (CG) are believed to enhance exercise performance and recovery by improving central hemodynamic responses. However, evidence is inconclusive. We performed a systematic review and meta-analysis to determine the effect of wearing CG at rest or after a physiological challenge on central hemodynamic responses, including cardiac output, stroke volume (SV), heart rate (HR), systolic blood pressure, diastolic blood pressure (DBP), and systemic vascular resistance in healthy individuals. The English language searches of the electronic databases SPORTDiscus, MEDLINE, and Web of Science were conducted from November 2018-February 2019. The studies involved were limited to the following: (a) original articles; (b) randomized controlled trials; (c) monitoring of central hemodynamic responses (either at rest or after a physiological challenge: maximal exercise or orthostatic challenge); and (d) healthy individuals. Of the 786 studies identified, 12 were included in the systematic review and meta-analysis. Meta-analysis was performed by the restricted maximum likelihood method. The results indicated that the effect size (ES) of wearing CG on improving central hemodynamic responses was large overall (Hedges' g = 0.55) and was large in SV (Hedges' g = 1.09) and HR (Hedges' g = 0.65). Subgroup analysis showed that the ESs in "post-physiological challenge" was large in overall (Hedges' g = 0.98), SV (Hedges' g = 1.78), HR (Hedges' g = 1.10), and DBP (Hedges' g = 0.75). Their ESs in "at rest" were not significant in all central hemodynamic responses, apart from a significant medium ES observed in SV (Hedges' g = 0.44). Healthy individuals who wear CG have marked improvement in central hemodynamic responses, particularly after a physiological challenge. More pronounced effects of CG are observed in increasing SV and reducing HR.
Collapse
Affiliation(s)
- Daniel C W Lee
- Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Hong Kong.,Elite Training Science and Technology Division, Hong Kong Sports Institute, Hong Kong
| | - Ajmol Ali
- Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Hong Kong.,School of Sport, Exercise, and Nutrition, Massey University, Auckland, New Zealand
| | - Sinead Sheridan
- Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Hong Kong
| | - Derwin K C Chan
- Department of Early Childhood Education, Faculty of Education and Human Development, The Education University of Hong Kong, Hong Kong
| | - Stephen H S Wong
- Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Hong Kong
| |
Collapse
|
8
|
Incidence of Achilles tendinopathy and associated risk factors in recreational runners: A large prospective cohort study. J Sci Med Sport 2020; 23:448-452. [DOI: 10.1016/j.jsams.2019.12.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 12/10/2019] [Accepted: 12/15/2019] [Indexed: 01/03/2023]
|
9
|
A Novel Capacitance-Based In-Situ Pressure Sensor for Wearable Compression Garments. MICROMACHINES 2019; 10:mi10110743. [PMID: 31683626 PMCID: PMC6915609 DOI: 10.3390/mi10110743] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 10/25/2019] [Accepted: 10/29/2019] [Indexed: 11/20/2022]
Abstract
This paper pertains to the development & evaluation of a dielectric electroactive polymer-based tactile pressure sensor and its circuitry. The evaluations conceived target the sensor’s use case as an in-situ measurement device assessing load conditions imposed by compression garments in either static form or dynamic pulsations. Several testing protocols are described to evaluate and characterize the sensor’s effectiveness for static and dynamic response such as repeatability, linearity, dynamic effectiveness, hysteresis effects of the sensor under static conditions, sensitivity to measurement surface curvature and temperature and humidity effects. Compared to pneumatic sensors in similar physiological applications, this sensor presents several significant advantages including better spatial resolution, compact packaging, manufacturability for smaller footprints and overall simplicity for use in array configurations. The sampling rates and sensitivity are also less prone to variability compared to pneumatic pressure sensors. The presented sensor has a high sampling rate of 285 Hz that can further assist with the physiological applications targeted for improved cardiac performance. An average error of ± 5.0 mmHg with a frequency of 1–2 Hz over a range of 0 to 120 mmHg was achieved when tested cyclically.
Collapse
|
10
|
Effects of Exercise Compression Stockings on Anterior Muscle Compartment Pressure and Oxygenation During Running: A Randomized Crossover Trial Conducted in Healthy Recreational Runners. Sports Med 2019; 49:1465-1473. [PMID: 31093922 PMCID: PMC6684544 DOI: 10.1007/s40279-019-01103-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Background Exercise compression garments have increased in popularity among athletes at all levels during the last 10 years. However, the scientific grounds for this are unclear. The purpose of the present study was to examine the effect of wearing exercise compression stockings (CS) on the anterior compartment pressure, oxygenation of the tibialis anterior muscle, and early blood biomarkers change for muscle damage during a 10-km treadmill run in healthy subjects. Methods Twenty healthy subjects completed two identical treadmill runs, with or without CS. The subjects were randomized regarding the order in which the sessions were performed. Intramuscular pressure (IMP) and muscle oxygenation in the one leg were continuously measured before, during, and after running sessions. Blood samples were collected just before and directly after these sessions and analyzed for myoglobin and creatine kinase concentrations. Results The use of CS during running resulted in significantly higher IMP (by 22 ± 3.1 mmHg on average) and lower tissue oxygenation index (by 11 ± 1.8%) compared to running without CS (p < 0.001). In addition, the Δ change in median serum myoglobin concentration measured before and after running was significantly higher when CS were used: 58 (9‒210) µg/L as compared to 38 (0‒196) µg/L with no CS (p = 0.04). No difference in post-running early serum creatine kinase concentration was observed between using CS and not using CS. Conclusion Wearing exercise CS during and following a 10-km treadmill run elevated IMP and reduced muscle tissue oxygenation in the anterior compartment of healthy runners. Furthermore, the use of exercise CS did not prevent early exercise-induced muscle damage, as measured by serum biomarkers.
Collapse
|
11
|
Zuj KA, Prince CN, Hughson RL, Peterson SD. Enhanced muscle blood flow with intermittent pneumatic compression of the lower leg during plantar flexion exercise and recovery. J Appl Physiol (1985) 2017; 124:302-311. [PMID: 29122964 DOI: 10.1152/japplphysiol.00784.2017] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study tested the hypothesis that intermittent compression of the lower limb would increase blood flow during exercise and postexercise recovery. Data were collected from 12 healthy individuals (8 men) who performed 3 min of standing plantar flexion exercise. The following three conditions were tested: no applied compression (NoComp), compression during the exercise period only (ExComp), and compression during 2 min of standing postexercise recovery. Doppler ultrasound was used to determine superficial femoral artery (SFA) blood flow responses. Mean arterial pressure (MAP) and cardiac stroke volume (SV) were assessed using finger photoplethysmography, with vascular conductance (VC) calculated as VC = SFA flow/MAP. Compared with the NoComp condition, compression resulted in increased MAP during exercise [+3.5 ± 4.1 mmHg (mean ± SD)] but not during postexercise recovery (+1.6 ± 5.9 mmHg). SV increased with compression during both exercise (+4.8 ± 5.1 ml) and recovery (+8.0 ± 6.6 ml) compared with NoComp. There was a greater increase in SFA flow with compression during exercise (+52.1 ± 57.2 ml/min) and during recovery (+58.6 ± 56.7 ml/min). VC immediately following exercise was also significantly greater in the ExComp condition compared with the NoComp condition (+0.57 ± 0.42 ml·min-1·mmHg-1), suggesting the observed increase in blood flow during exercise was in part because of changes in VC. Results from this study support the hypothesis that intermittent compression applied during exercise and recovery from exercise results in increased limb blood flow, potentially contributing to changes in exercise performance and recovery. NEW & NOTEWORTHY Blood flow to working skeletal muscle is achieved in part through the rhythmic actions of the skeletal muscle pump. This study demonstrated that the application of intermittent pneumatic compression during the diastolic phase of the cardiac cycle, to mimic the mechanical actions of the muscle pump, accentuates muscle blood flow during exercise and elevates blood flow during the postexercise recovery period. Intermittent compression during and after exercise might have implications for exercise performance and recovery.
Collapse
Affiliation(s)
- K A Zuj
- University of Waterloo, Department of Kinesiology , Waterloo, Ontario , Canada
| | - C N Prince
- University of Waterloo, Department of Mechanical and Mechatronics Engineering , Waterloo, Ontario , Canada
| | - R L Hughson
- University of Waterloo, Department of Kinesiology , Waterloo, Ontario , Canada.,Schlegel-University of Waterloo Research Institute for Aging , Waterloo, Ontario , Canada
| | - S D Peterson
- University of Waterloo, Department of Mechanical and Mechatronics Engineering , Waterloo, Ontario , Canada
| |
Collapse
|