1
|
Kosko B, Thielhelm TP, Ahluwalia R, Levy M, Kosko J. Bilateral vocal cord paralysis caused by accidental button battery ingestion in children: A case report and literature review. EAR, NOSE & THROAT JOURNAL 2024; 103:163-167. [PMID: 34541933 DOI: 10.1177/01455613211043678] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Button battery ingestion in pediatric populations is a common occurrence with severe sequelae. Multiple case reports have established the occurrence of death, fistula formation, mucosal erosion, esophageal perforation, and bleeding post-ingestion of button batteries. However, there is a gap in the literature on the occurrence of bilateral vocal cord paralysis post-lithium battery ingestion. We present a case in which a 12-month-old male developed bilateral vocal cord paralysis following ingestion of a button battery. We compare our case to eleven other reports that exist in the literature based on age, sex, time until removal, clinical presentation, day upon which vocal cord paralysis developed, anatomic location, and post-operative course. We conclude that bilateral vocal cord paralysis is a time-sensitive complication which requires prompt diagnosis. Any child with stridor following button battery ingestion should undergo consultation with pediatric otolaryngology immediately. In addition, long-term follow-up is necessary to evaluate return of normal vocal cord function.
Collapse
Affiliation(s)
- Brendan Kosko
- Florida State University College of Medicine, Tallahassee, FL, USA
| | - Torin P Thielhelm
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Ranbir Ahluwalia
- Florida State University College of Medicine, Tallahassee, FL, USA
| | - Marc Levy
- Children's Surgical Associates, Orlando, FL, USA
| | - James Kosko
- Children's Ears, Nose, Throat, and Allergy, Orlando, FL, USA
| |
Collapse
|
2
|
Zhang F, Duan Q, Zhou C, Wang G, Zhang J, Ni X. Animal study: Basic mechanism of vocal cord paralysis caused by button battery ingestion in children. Int J Pediatr Otorhinolaryngol 2024; 177:111872. [PMID: 38286078 DOI: 10.1016/j.ijporl.2024.111872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/15/2024] [Accepted: 01/20/2024] [Indexed: 01/31/2024]
Abstract
PURPOSE Vocal cord paralysis has been reported as a common complication of button battery (BB) ingestion, and there is a need to confirm the mechanism of vocal cord paralysis for the development of a standardized treatment. METHODS A new CR2032 BB and artificial saliva were placed in a fresh pig esophagus with the recurrent laryngeal nerve (RLN); the negative electrode faced the nerve in the experimental group, while the positive electrode faced the nerve in the control group. The pH values of the intra- and extraesophageal walls were measured simultaneously. Pathological examination was performed after the esophagus and nerves were damaged. RESULTS After BB ingestion, the pH near the intraesophageal negative electrode increased rapidly, reaching 11.5 at 30 min and over 14 at 6 h, while the extraesophageal pH did not change at 1 h and began to accelerate after 2 h, reaching 10 at 6 h. After 6 h of exposure, the pathological section showed that the structure of the mucosa, submucosa, and muscle layer were destroyed; chromatin in the nucleus faded, and part of the nerve bundle in the adventitia had liquefaction necrosis. CONCLUSION The basic mechanism of vocal cord paralysis caused by BB ingestion is that the OH- generated by the electrolytic reaction of the negative electrode penetrates the esophageal wall and corrodes the RLN, which may be the cause of vocal cord paralysis caused by BB ingestion without esophageal perforation.
Collapse
Affiliation(s)
- Fengzhen Zhang
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China; Beijing Key Laboratory for Pediatric Diseases of Otolaryngology, Head and Neck Surgery, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China
| | - Qingchuan Duan
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China; Beijing Key Laboratory for Pediatric Diseases of Otolaryngology, Head and Neck Surgery, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China
| | - Chunju Zhou
- Department of Pathology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China
| | - Guixiang Wang
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China; Beijing Key Laboratory for Pediatric Diseases of Otolaryngology, Head and Neck Surgery, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China
| | - Jie Zhang
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China; Beijing Key Laboratory for Pediatric Diseases of Otolaryngology, Head and Neck Surgery, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China.
| | - Xin Ni
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China; Beijing Key Laboratory for Pediatric Diseases of Otolaryngology, Head and Neck Surgery, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 10045, China.
| |
Collapse
|
3
|
Cohen WG, Mchugh M, Giordano T, Jacobs IN. Anatomic Considerations of esophageal button battery ingestion for outcomes and imaging. Int J Pediatr Otorhinolaryngol 2024; 176:111803. [PMID: 38043185 DOI: 10.1016/j.ijporl.2023.111803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 11/05/2023] [Accepted: 11/21/2023] [Indexed: 12/05/2023]
Abstract
INTRODUCTION Button batteries (BB) are a source of significant morbidity and mortality in young children. Little data is available regarding associations between esophageal impaction location and outcomes or need for surveillance imaging. METHODS All patients treated at a single institution following BB ingestion between 2018 and 2022 were included for retrospective chart review. RESULTS Twenty patients were treated at our institution BBs were located, or most significant damage observed, in the cervical esophagus (n = 10, 50 %), followed by thoracic esophagus (n = 6, 30 %), and abdominal esophagus (n = 4, 20 %). Patients with cervical esophageal impaction were younger (482 [370-866] days), than those with thoracic (1395 [871-2369] days) or abdominal esophageal impaction (2021.5 [1230.5-3419.5] days) (p = 0.003). Zargar Mucosal Injury Grade was significantly more severe in patients with cervical button battery impaction; 8/10 (80 %) had a ≥Grade IIIB injury, compared to 2/6 (33.3 %) thoracic impactions and 0/4 (0 %) abdominal impactions (p = 0.002). All patients who developed persistent esophageal stenosis (n = 6) had cervical battery impactions (6, 60 %, p = 0.015). Both TEFs (2/2) had anterior facing anode, while both (2/2) esophageal perforations had posterior. Only 1/20 (5 %) patients, and 1/7 (14.3 %) with serious complications, had a serious complication detected on routine, rather than clinically indicated follow-up surveillance. CONCLUSIONS In our population, cervical BB impaction occurred more frequently in younger children, was associated with more severe mucosal injury, and had higher risk of stenosis. Nearly all complications were detected on clinically indicated rather than postoperative surveillance imaging.
Collapse
Affiliation(s)
- William G Cohen
- Division of Otolaryngology, Children's Hospital of Philadelphia, Philadelphia, PA, 19104, USA; Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Moira Mchugh
- Division of Otolaryngology, Children's Hospital of Philadelphia, Philadelphia, PA, 19104, USA
| | - Terri Giordano
- Division of Otolaryngology, Children's Hospital of Philadelphia, Philadelphia, PA, 19104, USA
| | - Ian N Jacobs
- Division of Otolaryngology, Children's Hospital of Philadelphia, Philadelphia, PA, 19104, USA; Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA.
| |
Collapse
|
4
|
Ren S, Lopes H, Masters N. Video Laryngoscope Assistance in Button Battery Retrieval. Case Rep Anesthesiol 2023; 2023:8550685. [PMID: 37711750 PMCID: PMC10499533 DOI: 10.1155/2023/8550685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/19/2023] [Accepted: 08/25/2023] [Indexed: 09/16/2023] Open
Abstract
Foreign body ingestion remains a common cause of pediatric emergency surgery with button battery ingestion of particular concern. Newer, higher power lithium batteries can cause catastrophic damage of the gastrointestinal tract through erosion of mucosa into surrounding structures. Prompt diagnosis and treatment are paramount. We present a case of an 11-month-old with a button battery lodged in the proximal esophagus. The extraction was difficult and only made possible with the assistance of a video laryngoscope. We make the case for more routine usage of video laryngoscopy for removal of foreign bodies in the upper esophagus.
Collapse
Affiliation(s)
- Sandy Ren
- Department of Anesthesiology, Perioperative Medicine and Pain Management, Miller School of Medicine, University of Miami, Miami, Florida, USA
- Department of Anesthesiology, Perioperative Medicine and Pain Management, Jackson Memorial Hospital, Miami, Florida, USA
| | - Heitor Lopes
- Department of Anesthesiology, Perioperative Medicine and Pain Management, Miller School of Medicine, University of Miami, Miami, Florida, USA
- Department of Anesthesiology, Perioperative Medicine and Pain Management, Jackson Memorial Hospital, Miami, Florida, USA
| | - Neil Masters
- Department of Anesthesiology, Perioperative Medicine and Pain Management, Miller School of Medicine, University of Miami, Miami, Florida, USA
| |
Collapse
|
5
|
Ahmed ME, Refaie BM, Ahmed ME, Ali AHA, Dahy KG. Foreign body Swallows with Airway Affection in Pediatrics. Indian J Otolaryngol Head Neck Surg 2023; 75:287-291. [PMID: 37275045 PMCID: PMC10235239 DOI: 10.1007/s12070-022-03156-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 09/05/2022] [Indexed: 11/06/2022] Open
Abstract
Aims The current work aimed at evaluating how FBI can cause respiratory distress and stridor as well as their severity according to age, gender, lodgment site, and type of the object. Factors influencing morbidity and mortality among studied patients will be deliberated as well. Methods It is a hospital-based descriptive study where all children between birth and 16 years of age who were admitted to Sohag University Hospital, Egypt from January 1st, 2018, to December 31st, 2020, for FBs removal were analyzed. All cases were subjected to complete history taking, physical, radiological, and bronchoscopic examination. Results A total of fourteen [14] patients were presented with FBI based on a full history, examination, and essential investigation. The vast majority 92.9% of presented cases (13 out of 14) were less than 6 years old. 50% of them (50%) (7 out of 14) were less than one year old. Most cases presented early within a few hours after ingestion (71.4%). Two [2] patients had predisposing conditions like mental retardation and cerebral palsy. 28.6% of cases presented late (> 24 h after aspiration). Except for one case where a cervical oesophageal approach was needed. Endoscopic extractions of foreign bodies were successfully done. 50% of patients required admissions to the Pediatric Intensive Care Unit (PICU). The mortality rate was 14.3%. Conclusion FBI is a common clinical emergency in children younger than 6 years. A high index of suspicion is the keystone for diagnosis. Early detection and management are crucial for a positive outcome.
Collapse
Affiliation(s)
| | | | - Mona Elrabie Ahmed
- Mona Elrabie Ahmed Phoniatrics unit, ENT Department, Faculty of Medicine, Sohag University, Sohag, Egypt
| | | | | |
Collapse
|
6
|
Poupore NS, Shih MC, Nguyen SA, Brennan EA, Clemmens CS, Pecha PP, McDuffie LA, Carroll WW. Evaluating the management timeline of tracheoesophageal fistulas secondary to button batteries: A systematic review. Int J Pediatr Otorhinolaryngol 2022; 157:111100. [PMID: 35523610 DOI: 10.1016/j.ijporl.2022.111100] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 02/21/2022] [Accepted: 03/02/2022] [Indexed: 10/18/2022]
Abstract
INTRODUCTION During the SARS-CoV-2 pandemic, the incidence of pediatric button battery (BB) ingestions has risen. Children have spent more time at home from school, while many parents try to balance working from home and childcare. Additionally, the amount of electronics powered by BB has increased. Tracheoesophageal fistula (TEF) secondary to a retained aerodigestive BB is a devastating development. Management is challenging, and the clinical timeline of watchful waiting versus surgical intervention for TEF is poorly defined in the literature. METHODS In accordance with PRISMA guidelines, databases searched include PubMed, Scopus, and CINAHL from database date of inception through August 13, 2021. All study designs were included, and no language, publication date, or other restrictions were applied. Case series and reports of TEFs secondary to BBs were included. Clinical risk factors and outcomes were compared between the spontaneous closure and surgical repair groups. RESULTS A total of 79 studies with 105 total patients were included. Mortality was 11.4%. There were 23 (21.9%) TEFs that spontaneously closed and 71 (67.6%) that underwent surgical repair. Median time to spontaneous closure compared to surgical repair was significantly different (8.0 weeks [IQR 4.0-18.4] vs. 2.0 weeks [IQR 0.1-3.3], p<0.001). Smaller TEFs were more likely to spontaneously close versus being surgically repaired (9.3 mm ± 3.5 vs. 14.9 mm ± 8.3, p=0.022). Duration of symptoms before BB discovery, BB size, time between BB removal and TEF discovery, and location of the TEF were not statistically different between the spontaneous closure and surgical repair groups. CONCLUSION A TEF secondary to BB ingestion is a potentially deadly complication. Timing of reported TEF spontaneous closure varies significantly. While smaller TEFs may be amenable to healing without surgical repair, no other significant factors were identified that may be associated with spontaneous closure. If clinical status permits, these data suggest a period of observation of at least 8 weeks prior to surgical intervention may be practical for many BB-induced TEFs.
Collapse
Affiliation(s)
- Nicolas S Poupore
- Medical University of South Carolina, Department of Otolaryngology - Head and Neck Surgery, 135 Rutledge Avenue, MSC550, Charleston, SC, 29425, USA; University of South Carolina School of Medicine Greenville, 607 Grove Road, Greenville, SC, 29605, USA.
| | - Michael C Shih
- Medical University of South Carolina, Department of Otolaryngology - Head and Neck Surgery, 135 Rutledge Avenue, MSC550, Charleston, SC, 29425, USA; Baylor College of Medicine, One Baylor Plaza, Houston, TX, 77030, USA
| | - Shaun A Nguyen
- Medical University of South Carolina, Department of Otolaryngology - Head and Neck Surgery, 135 Rutledge Avenue, MSC550, Charleston, SC, 29425, USA
| | - Emily A Brennan
- Medical University of South Carolina, Department of Research and Education Services, Medical University of South Carolina Libraries, 171 Ashley Avenue, Charleston, SC, 29425, USA
| | - Clarice S Clemmens
- Medical University of South Carolina, Department of Otolaryngology - Head and Neck Surgery, 135 Rutledge Avenue, MSC550, Charleston, SC, 29425, USA
| | - Phayvanh P Pecha
- Medical University of South Carolina, Department of Otolaryngology - Head and Neck Surgery, 135 Rutledge Avenue, MSC550, Charleston, SC, 29425, USA
| | - Lucas A McDuffie
- Medical University of South Carolina, Department of Surgery, 96 Jonathan Lucas Street, Charleston, SC, 29425, USA
| | - William W Carroll
- Medical University of South Carolina, Department of Otolaryngology - Head and Neck Surgery, 135 Rutledge Avenue, MSC550, Charleston, SC, 29425, USA
| |
Collapse
|
7
|
Philteos J, James AL, Propst EJ, Ostrow O, McKinnon N, Everett T, Wolter NE. Airway Complications Resulting From Pediatric Esophageal Button Battery Impaction: A Systematic Review. JAMA Otolaryngol Head Neck Surg 2022; 148:677-683. [PMID: 35616924 DOI: 10.1001/jamaoto.2022.0848] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Button batteries (BBs) are commonly found in many household items and present a risk of severe injury to children if ingested. The direct apposition of the trachea and recurrent laryngeal nerves with the esophagus puts children at risk of airway injury secondary to the liquefactive necrotic effects of BB impactions. Objective To review airway injuries, including long-term sequelae, after BB ingestion in children. Evidence Review For this systematic review, a comprehensive strategy was designed to search MEDLINE, Embase, Cochrane Database of Systematic Reviews, Web of Science, and CINAHL (Cumulative Index of Nursing and Allied Health Literature) from inception to July 31, 2021, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) reporting guideline. Additional cases were identified from the National Capital Poison Center BB registry. Individual authors were contacted for additional information. Studies with pediatric patients (<18 years) who developed airway injuries after BB ingestion were included. A total of 195 patients were included in the analysis; 95 were male. The mean (SD) age at BB ingestion was 17.8 (10.2) months. The mean (SD) time from BB ingestion to removal was 5.8 (9.0) days. The 2 most common airway sequelae observed in our series were 155 tracheoesophageal fistulae and 16 unilateral vocal cord paralyses. Twenty-three children had bilateral vocal cord paralysis. The mean (SD) duration of ingestion leading to vocal cord paralysis was shorter than that of the general cohort (17.8 [22.5] hours vs 138.7 [216.7] hours, respectively). Children presenting with airway symptoms were likely to have a subsequent tracheoesophageal fistula or vocal cord paralysis. Conclusions and Relevance Airway injuries are a severe consequence of BB ingestion, occurring more often in younger children. This systematic review found that tracheoesophageal fistulae and vocal cord paralyses were the 2 most common airway injuries, often requiring tracheostomy. Vocal cord injury occurred after a shorter BB exposure time than other airway injuries. Continued efforts should be directed toward prevention strategies to avoid the devastating sequelae of BB-associated airway injury.
Collapse
Affiliation(s)
- Justine Philteos
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Adrian L James
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Evan J Propst
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Olivia Ostrow
- Division of Pediatric Emergency Medicine, Department of Pediatrics, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Nicole McKinnon
- Department of Critical Care Medicine, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Tobias Everett
- Department of Anesthesiology and Pain Medicine, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Nikolaus E Wolter
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
8
|
Razumovskiy AY, Stepanenko NS, Kulikova NV, Teplov VO. [Treatment of complications following esophageal electrochemical burns by batteries in children]. Khirurgiia (Mosk) 2022:54-59. [PMID: 35477201 DOI: 10.17116/hirurgia202204154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To determine the optimal treatment of patients with complications of esophageal electrochemical burns by batteries. MATERIAL AND METHODS There were 75 children with esophageal electrochemical burns by batteries between 2010 and 2019. All children underwent X-ray of the cervical spine, chest and abdomen, esophagoscopy with removal of the battery, tracheoscopy. Complications occurred in 39 children: TEF - 21, esophageal stenosis - 19, laryngeal paresis - 14, esophageal perforation - 3. Patients with TEF were divided into 2 groups: clinically stable children without respiratory failure and severe illness with respiratory failure including mechanical ventilation. Group I consisted of 6 children, four of them underwent laparoscopic Nissen fundoplication and gastrostomy. Group II consisted of 15 children. In acute period, 3 children underwent laparoscopic fundoplication and gastrostomy, 8 ones - TEF ligation, 4 patients - tracheal repair with esophageal flap and esophageal extirpation. Patients with esophageal stenosis underwent bougienage. Patients with esophageal perforation required therapy. Tracheostomy was necessary for respiratory failure and bilateral laryngeal paresis. Lateralization procedures were performed in patients with negative course of disease. RESULTS In the 1st group, spontaneous closure of TEF was found in 3 children after fundoplication and gastrostomy. One child underwent thoracoscopic disconnection of TEF after reduction of fistula. In the 2nd group, fundoplication resulted spontaneous closure of fistula after 2-5 months. In 4 children, recanalization of the fistula or esophageal failure were observed in acute period after TEF ligation. CONCLUSION Laparoscopic fundoplication and gastrostomy are optimal for TEF and can result complete or partial spontaneous closure of TEF. If radical procedure is necessary in acute period, tracheal repair with esophageal flap and extirpation of the esophagus with subsequent coloesophagoplasty should be considered.
Collapse
Affiliation(s)
- A Yu Razumovskiy
- Pirogov National Research Medical University, Moscow, Russia.,N.F. Filatov Children's City Clinical Hospital, Moscow, Russia
| | - N S Stepanenko
- Pirogov National Research Medical University, Moscow, Russia.,N.F. Filatov Children's City Clinical Hospital, Moscow, Russia
| | - N V Kulikova
- N.F. Filatov Children's City Clinical Hospital, Moscow, Russia
| | - V O Teplov
- Pirogov National Research Medical University, Moscow, Russia
| |
Collapse
|
9
|
Association between the corrosion of ingested lithium button battery in the esophagus and its complications in pediatric patients. Emerg Radiol 2022; 29:455-460. [PMID: 35182254 DOI: 10.1007/s10140-022-02033-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 02/14/2022] [Indexed: 10/19/2022]
Abstract
PURPOSE The incidence of lithium button battery ingestion has been increasing recently, which results in severe complications. We aimed to demonstrate the association between the corrosion of lithium button batteries in the esophagus on radiographs and their complications. METHODS The nine pediatric patients included in this study were classified into two groups based on the presence of severe complications. The presence and degree of corrosion on plain radiographs were evaluated. The degree of corrosion was classified into the following three grades; none: 0%; moderate: 1-50%; severe: 51-100%. Fisher's exact test was used for statistical analyses. RESULTS Of the nine patients, five showed complications. The number of patients who had grade none, moderate, and severe degrees of corrosion was three, four, and two, respectively. The incidence of severe complications differed significantly between the incidence of lithium button batteries' contour (without vs. with severe complications [presence/absence of corrosion] = 1/3 vs. 5/0, respectively; P = 0.0476). In cases with "none" degree of corrosion, all three cases had no complication, and in cases with a "severe" degree of corrosion, all two cases had complications. CONCLUSION The cases with the presence of corrosion of lithium button batteries had a higher tendency to have severe complications. Therefore, physicians should anticipate the presence of severe complications in pediatric patients with corrosion more than those without corrosion.
Collapse
|
10
|
Rashed Y, Khalfan K. Button Batteries and High-Powered Neodymium Magnet Ingestion in Children. Open Access Maced J Med Sci 2022. [DOI: 10.3889/oamjms.2022.8292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND: Foreign body ingestions in pediatrics are present highly variably. For each case, it is important to consider the size of the child, the age of the child, the size of the object, and the inherently different risk of different objects ingested. It is important to note that regardless of the type of object, any foreign body should be removed from the esophagus. Over the past decade, the medical literature has particularly identified the potential for morbidity and mortality in cases of button battery and magnet ingestions.
AIM: This study aims to describe the complications and how to avoid them in addition to studying the role of early endoscopic intervention in cases of button batteries (BB) and multiple magnets ingestion in children.
METHODS: There were 151 children enrolled in the study, classified into two groups. The first group constitutes ninety children with BB, the other group sixty children with multiple magnets ingestion. In addition to one patient with both multiple magnets and battery ingestion, which are extracted endoscopically from the stomach without complication. BB detected in the upper gastrointestinal tract (GIT) in the esophagus, stomach, and duodenum in 70 patients were extracted endoscopically. Other 20 patients where the batteries were detected distal to duodenum were observed till the discharge of batteries was confirmed. In patients with multiple magnets, the magnets were in the upper GIT in 46 patients while found distal to the duodenum in 14 patients.
RESULTS: There were 151 children enrolled in the study, classified into two groups. The first group constitutes ninety children with BB, the other group sixty children with multiple magnets ingestion. In addition to one patient with both multiple magnets and battery ingestion, which are extracted endoscopically from the stomach without complication. BB detected in the upper GIT in the esophagus, stomach, and duodenum in 70 patients were extracted endoscopically. Other 20 patients where the batteries were detected distal to duodenum were observed until the discharge of batteries was confirmed. In patients with multiple magnets, the magnets were in the upper GIT in 46 patients while found distal to the duodenum in 14 patients.
CONCLUSION: This study put alarm that multiple magnets ingestion carries a high risk of gastrointestinal perforation compared to battery ingestion. Invitation to ban on the sale of products with high-powered neodymium magnets, such as Buckyballs and Buckycubes, and to keep BB difficult reachable by children. In addition to encouraging urgent endoscopic management of suspected BB or multiple magnets ingestion.
Collapse
|