1
|
Behbehani M, AlAtwan AA, AlHaddad A. Colon diverticulosis adherent to mesh plug migration after laparoscopic hernia repair: A case study and review of literature. Int J Surg Case Rep 2021; 87:106403. [PMID: 34537527 PMCID: PMC8449232 DOI: 10.1016/j.ijscr.2021.106403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/10/2021] [Accepted: 09/10/2021] [Indexed: 11/28/2022] Open
Abstract
Introduction Inguinal hernia repair has evolved from open suture methods to mesh repair which is preformed either open or laparoscopically. Mesh hernia repair has improved the outcome in regards to patient care and recurrence rate but it is also associated with a number of complications. The complications of mesh hernia repair such as deep seated infections, mesh erosion and mesh perforation into nearby viscera has been scarcely reported in literature. Case presentation We report a 43 years old male case of diverticulosis adherent to a migrated mesh plug from previous laparoscopic inguinal hernia repair procedure. Discussion The choice of mesh material, appropriate suture placement and closure of the peritoneum after mesh repair is very crucial to avoid long term mesh complications. Conclusion The aim of this case report is to present a rare complication of mesh erosion with colovesical fistula and abscess formation. Inguinal hernia repair is one of the most common procedures performed in surgical practice. Mesh hernia repair has improved patient outcomes; regardless it is associated with some complications. Mesh migration as a complication should be thought of in patients presenting with acute abdomen.
Collapse
|
2
|
Johnston S, Lau C, Dargusch MS, Atrens A. Absorbable Mg surgical tack: Proof of concept &in situ fixation strength. J Mech Behav Biomed Mater 2019; 97:321-329. [PMID: 31153113 DOI: 10.1016/j.jmbbm.2019.05.035] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 05/20/2019] [Accepted: 05/21/2019] [Indexed: 11/30/2022]
Abstract
A prototype magnesium (Mg) surgical tack is tested comparatively against commercially available tacks made of titanium (ProTacktm, Medtronic) and PLGA (AbsorbaTacktm, Medtronic). The pull-out force is measured in situ in a lap-shear pull-out test, using porcine abdominal muscle tissue as a model. The Mg tack had a pull-out force comparable to those of the commercially available tacks. The majority of the Mg tacks also had a more ductile failure mode (i.e. the tacks deformed prior to failure), compared to the commercial tacks which pulled directly from the tissue with no deformation. The Mg tacks deformed as they were removed from the tissue, causing less damage to the tissue in the process. This is the first reported use of a Mg alloy in this application, and the proof of concept indicates that this is an area that deserves further interest and study.
Collapse
Affiliation(s)
- Sean Johnston
- The University of Queensland, Materials Engineering, School of Mechanical & Mining Engineering, Brisbane, Qld, 4072, Australia; The University of Queensland, Centre for Advanced Materials Processing and Manufacturing (AMPAM), Brisbane, Qld, 4072, Australia.
| | - Cora Lau
- The University of Queensland, Biological Resources, Brisbane, Qld, 4072, Australia
| | - Matthew S Dargusch
- The University of Queensland, Centre for Advanced Materials Processing and Manufacturing (AMPAM), Brisbane, Qld, 4072, Australia
| | - Andrej Atrens
- The University of Queensland, Materials Engineering, School of Mechanical & Mining Engineering, Brisbane, Qld, 4072, Australia
| |
Collapse
|
3
|
Stetsko T, Bury K, Lubowiecka I, Szymczak C, Tomaszewska A, Śmietański M. Safety and efficacy of a Ventralight ST echo ps implant for a laparoscopic ventral hernia repair - a prospective cohort study with a one-year follow-up. POLISH JOURNAL OF SURGERY 2017; 88:7-14. [PMID: 27096768 DOI: 10.1515/pjs-2016-0020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Indexed: 11/15/2022]
Abstract
UNLABELLED Laparoscopic ventral hernia repair has become popular technique. Every year, companies are introducing new products Thus, every mesh prior to introduction in clinical settings should be tested with a dedicated tacker to discover the proper fixation algorithm. The aim of the study was to assess the safety and efficacy of the Ventralight ST implant with an ECHO positioning system and a dedicated fixation device, the SorbaFix stapler, in a prospective cohort of patients. MATERIAL AND METHODS The study was a prospective single centre cohort study with a one-year followup period. Fifty-two patients received operations for a ventral hernia using a laparoscopic IPOM mesh - Ventralight ST ECHO PS. The size of the mesh and the fixation method were based on mathematical considerations. A recurrence of the hernia and pain after 1, 2 and 12 months were assessed as the primary endpoints. RESULTS Two recurrences were noted, one in parastomal and one in a large incisional hernia. Pain was observed in 22 patients (41%) and mostly disappeared after 3 months (7%). The intensity of pain was low (VAS <2). However, 2 patients still experienced severe pain (VAS>6) until the end of the study. CONCLUSION The Ventralight ST Echo PS implant fixed with a Sorbafix stapler is a valuable and safe option for a laparoscopic ventral hernia repair. In our opinion, the implant could be used in all patients due to the hernia ring diameter. According to the mathematical models and clinical practice, we do not recommend this implant in orifices with a width larger than 10 cm.
Collapse
|
4
|
Differences in midline fascial forces exist following laparoscopic and open transversus abdominis release in a porcine model. Surg Endosc 2016; 31:829-836. [PMID: 27352787 DOI: 10.1007/s00464-016-5040-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Accepted: 06/11/2016] [Indexed: 12/31/2022]
Abstract
INTRODUCTION Posterior component separation herniorrhaphy via transversus abdominis release (TAR) permits midline reapproximation of large fascial defects. To date, no report delineates the reduction in tensile force to reapproximate midline fascia following TAR. We hypothesized that open and laparoscopic TAR would provide similar reductions in midline reapproximation forces in a porcine model. METHODS Under general anesthesia, a 20-cm midline laparotomy was created and bilateral lipocutaneous flaps were raised to expose the anterior rectus sheath. Five stainless steel hooks were placed at 1-cm intervals lateral to the midline at three locations: 5 cm above, at, and 5 cm below the umbilicus bilaterally. Baseline force measurements were taken by pulling each lateral point to midline. Laparoscopic TAR was performed unilaterally by incising the parietal peritoneum and transversus muscle lateral to the linea semilunaris. Open TAR was performed contralaterally, and force measurements were repeated. Comparisons were made to baseline and between the groups. RESULTS Following laparoscopic TAR, 87 % (13/15) of points showed significant reduction compared to baseline forces, whereas only 20 % (3/15) of open TAR points had significant force reductions. Compared to open TAR, three locations favored the laparoscopic approach [1 cm lateral to midline, 5 cm above the umbilicus (p = 0.04; 95 % CI 0.78-1.00), 2 cm lateral to midline at the umbilicus (p = 0.04; 95 % CI 0.80-1.00), and 1 cm lateral to midline 5 cm below the umbilicus (p = 0.05; 95 % CI 0.79-1.00)]. The mean length of TAR was longer for laparoscopic than open at 27.29 versus 19.55 cm (p < 0.0001; 95 % CI 6.46-9.02). CONCLUSIONS Open TAR reduced midline tensile force at few locations, suggesting that the mechanism by which TAR facilitates herniorraphy may not solely be through reductions in linea alba tensile forces. At specific locations, laparoscopic TAR provides superior reduction in midline closure force compared to open TAR, likely as a result of a longer muscle release.
Collapse
|
5
|
Pawlak M, Hilgers RD, Bury K, Lehmann A, Owczuk R, Śmietański M. Comparison of two different concepts of mesh and fixation technique in laparoscopic ventral hernia repair: a randomized controlled trial. Surg Endosc 2015; 30:1188-97. [PMID: 26139491 DOI: 10.1007/s00464-015-4329-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Accepted: 06/09/2015] [Indexed: 12/14/2022]
Abstract
BACKGROUND Patients' need to improve outcomes and to reduce the number of complications triggers the development of new materials and surgery concepts. Currently, there are many implants and fixation systems dedicated for intraperitoneal onlay mesh procedure. The aim of this study was to compare two different mesh/fixation system concepts (PH: Physiomesh/Securestrap and VS: Ventralight ST/SorbaFix) for laparoscopic ventral hernia repair with respect to pain. METHODS A single-center, prospective, randomized study was designed to include 50 patients per group with a planned interim analysis for safety after 25 patients. The endpoints were pain occurrences and intensity, which was measured with the visual analogue scale 7 days, 30 days, 3 months and 6 months after surgery. The safety parameters included the number of recurrences and postoperative complications. RESULTS During the interim analysis, the study was stopped due to safety reasons. We observed five (20 %) recurrences in the PH group in first 6 months and none in the VS group. We observed a significantly higher pain rate in the PH group after 3 months (p < 0.0001) and no difference after 7 days (p = 0. 7019). The pain intensity decreased significantly over time (p < 0.0001) and was significantly higher in the PH group (p < 0.0001). CONCLUSIONS Although this clinical trial was terminated prior to the preplanned recruitment goal, the obtained results from the enrolled patients indicate that the PH system associated with significantly greater hernia recurrences and postoperative pain compared with the VS system. This confirms the superiority of the elastic mesh concept, which may be a safer and more efficacious option for laparoscopic ventral hernia repairs.
Collapse
Affiliation(s)
- Maciej Pawlak
- Department of General Surgery, Ceynowa Hospital, Wejherowo, Poland.
- Department of Cardiac and Vascular Surgery, Medical University of Gdańsk, Gdańsk, Poland.
| | | | - Kamil Bury
- Department of Cardiac and Vascular Surgery, Medical University of Gdańsk, Gdańsk, Poland
| | - Andrzej Lehmann
- Department of General Surgery, Ceynowa Hospital, Wejherowo, Poland
| | - Radosław Owczuk
- Department of Anesthesiology and Intensive Care, Medical University of Gdańsk, Gdańsk, Poland
| | - Maciej Śmietański
- II Department of Radiology, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
6
|
Laparoscopic ventral hernia repair: is there an optimal mesh fixation technique? A systematic review. Langenbecks Arch Surg 2014; 399:55-63. [PMID: 24121735 DOI: 10.1007/s00423-013-1126-x] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Accepted: 09/27/2013] [Indexed: 12/27/2022]
Abstract
PURPOSE The purpose of this study is to distinguish the optimal mesh fixation technique used in laparoscopic ventral hernia repair (LVHR). A particular fixation technique of the mesh to the abdominal wall is required, which should be strong enough to prevent migration of the mesh and, at the same time, keep injury to the abdominal wall minimal to prevent postoperative discomfort and pain. METHODS An extensive literature search was performed in the PubMed database from its onset until November 2012. All series of at least 30 patients operated by laparoscopy for a ventral hernia, with the use of a standardized surgical technique well-defined in the “Methods” section, and with a follow-up of at least 12 months were included. The series were categorized according to the technique of mesh fixation described: “tacks and sutures,” “tacks only,” and “sutures only.” For each treatment group, the recurrence rate was adjusted to the number of patients treated and the 95 % confidence interval was calculated. No overlap between two intervals was defined as a significant difference in recurrence rate. RESULTS A total of 25 series were included for statistical evaluation. Thirteen trials used both tacks and sutures, ten used only tacks, and two used only sutures. Overall recurrence rate was 2.7 % (95 % CI [1.9–3.4 %]). CONCLUSION None of the currently available mesh fixation techniques used for LVHR was found to be superior in preventing hernia recurrence as well as in reducing abdominal wall pain. The pain reported was remarkably high with all different fixation devices. Further research to develop solid and atraumatic fixation devices is warranted.
Collapse
|
7
|
Comparative evaluation of adhesions to intraperitoneally placed fixation materials: a laparoscopic study in rats: adhesions to fixation materials. Indian J Surg 2011; 72:475-80. [PMID: 22131658 DOI: 10.1007/s12262-010-0168-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2010] [Accepted: 07/14/2010] [Indexed: 10/18/2022] Open
Abstract
After laparoscopic ventral hernia repair, the nature of the adhesions to fixation materials or to mesh had not been clarified. We examined adhesion formation specific to the fixation material in rats. We designed an experimental laparoscopy setup, and placed four intraperitoneal fixation materials on the peritoneum of rats without a mesh graft. Another group of researchers documented the incidence and intensity of postoperative adhesion formation. The adhesion scores for the nickel-titanium anchor were significantly greater than those for polylactic acid (p = 0.004), a titanium tacker (p < 0.0001), and fibrin glue (p < 0.0001). No adhesions occurred in the fibrin glue group. Fibrin glue is the preferred fixation material because it produced no postoperative adhesions. The nickel-titanium anchor produced heavy adhesions but may be applicable for recurrent hernia cases and in patients with thin abdominal walls.
Collapse
|
8
|
Mcmahon M, Kehdy F. Article Commentary: Laparoscopic Repair of Inguinal and Incisional Hernias. Am Surg 2011. [DOI: 10.1177/000313481107700411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Meredith Mcmahon
- Department of Surgery, University of Louisville, Louisville, Kentucky
| | - Farid Kehdy
- Department of Surgery, University of Louisville, Louisville, Kentucky
| |
Collapse
|
9
|
Rieder E, Stoiber M, Scheikl V, Poglitsch M, Dal Borgo A, Prager G, Schima H. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes. J Am Coll Surg 2010; 212:80-6. [PMID: 21036072 DOI: 10.1016/j.jamcollsurg.2010.08.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2010] [Revised: 08/30/2010] [Accepted: 08/31/2010] [Indexed: 10/18/2022]
Abstract
BACKGROUND Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. STUDY DESIGN For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. RESULTS TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). CONCLUSIONS Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks.
Collapse
Affiliation(s)
- Erwin Rieder
- Department of General Surgery, Medical of University Vienna, Austria.
| | | | | | | | | | | | | |
Collapse
|
10
|
Bansal VK, Misra MC, Kumar S, Rao YK, Singhal P, Goswami A, Guleria S, Arora MK, Chabra A. A prospective randomized study comparing suture mesh fixation versus tacker mesh fixation for laparoscopic repair of incisional and ventral hernias. Surg Endosc 2010; 25:1431-8. [PMID: 20976495 DOI: 10.1007/s00464-010-1410-6] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2010] [Accepted: 09/03/2010] [Indexed: 11/25/2022]
Abstract
INTRODUCTION After the first report of laparoscopic incisional and ventral hernia repair (LIVHR) in 1993, several studies have proven its efficacy over open method. Among the technical issues, the technique of mesh fixation to the abdominal wall is still an area of debate. This prospective randomized study was done to compare two techniques of mesh fixation, i.e., tacker with four corner transfascial sutures versus transfascial sutures alone. MATERIALS AND METHODS 68 patients admitted for LIVHR repair (defect size less than 25 cm2) were randomized in two groups: group I, tacker fixation (36 patients) and group II, suture fixation (32 patients). Various intraoperative variables and postoperative outcomes were recorded and analyzed. RESULTS The patients in the two groups were well matched in terms of age, sex, body mass index (BMI), and hernia characteristics. Mean BMI was 29.0 kg/m2. Operative time was found to be significantly higher in group II (77.5 versus 52.6 min, p=0.000). Patients in group I were found to have significantly higher pain scores at 1 h, 6 h, 24 h, 1 week, 1 month, and 3 months postoperatively. At follow-up, incidence of seromas was higher in group II but the difference was not significant (7 versus 4, p=0.219). During long-term follow-up, patients in group II were satisfied cosmetically. CONCLUSION Suture fixation is a cost-effective alternative to tacker fixation, for small and medium-sized defects in anatomically accessible areas. However, suture fixation requires significantly longer operation time, but patients have statistically significantly less postoperative pain.
Collapse
Affiliation(s)
- Virinder Kumar Bansal
- Department of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, Room No. 5021, 5th Floor, Teaching Block, New Delhi, India.
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Khandelwal RG, Bibyan M, Reddy PK. Transfascial suture hernia: a rare form of recurrence after laparoscopic ventral hernia repair. J Laparoendosc Adv Surg Tech A 2010; 20:753-5. [PMID: 20874415 DOI: 10.1089/lap.2010.0314] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Laparoscopic repair of ventral or incisional hernia is among the most commonly performed minimally invasive procedures. Different modes of recurrence have been reported in literature, including missed defects, mesh migration, mesh infection, etc. Transfascial suture fixation in addition to tackers is an established method to prevent recurrence due to mesh migration. We report possibly the third case of recurrent ventral hernia with multiple defects at transfascial suture sites of previous laparoscopic ventral hernia mesh repair. The patient was treated by laparoscopy with a large intraperitoneal PROCEED mesh, covering the new hernia defects and older mesh.
Collapse
|
12
|
Grommes J, Binnebösel M, Klink CD, von Trotha KT, Junge K, Conze J. Different methods of mesh fixation in open retromuscular incisional hernia repair: a comparative study in pigs. Hernia 2010; 14:623-7. [PMID: 20835908 DOI: 10.1007/s10029-010-0725-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2010] [Accepted: 08/26/2010] [Indexed: 11/26/2022]
Abstract
PURPOSE Reinforcement of the abdominal wall with alloplastic mesh material in incisional hernia repair is well established. To avoid dislocation and migration of the prostheses, mesh fixation is recommended. However, there seems to be a correlation between postoperative pain and mesh fixation. Furthermore, it remains unclear whether mesh fixation is necessary at all. METHODS A retromuscular mesh implantation was performed in 36 pigs using a polypropylene-polyglecaprone 25 composite mesh (Ultrapro(®), 12 × 18 cm). In group 1, the mesh was fixed to the posterior rectus sheet with non absorbable single sutures (Prolene(®) 2-0), in group 2 fixation was with absorbable sutures (Vicryl(®) 2-0), in group 3 mesh fixation was with 5 ml fibrin sealant (Quixil(®)), and, as a control, there was no fixation in group 4. The abdominal wall was explanted on postoperative day 7, 14 and 56. Mesh size and position was measured, and pull-out force of the mesh was analysed mechanically by tensiometry. The ratio of collagen type I/III was analysed to determine the quality of mesh integration. RESULTS Neither mesh dislocation nor mesh migration was detected. Mesh size showed no significant differences, whether comparing time points or groups. No significant differences in the tensile strength of mesh integration were found when comparing the groups (group 1: 155 ± 17 mmHg; group 2: 175 ± 9 mmHg; group 3: 166 ± 24 mmHg; group 4: 172 ± 28 mmHg). Though the type I/III collagen ratio increased over time, no significant differences according to the type of fixation used were detected. CONCLUSION Mesh fixation in open incisional hernia repair with retromuscular mesh augmentation to avoid mesh dislocation or migration in the early postoperative period appears to be unnecessary.
Collapse
Affiliation(s)
- J Grommes
- Department of Vascular Surgery, University Hospital of RWTH Aachen, Pauwelsstr 30, 52074, Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
13
|
Fibrin glue for intraperitoneal laparoscopic mesh fixation: a comparative study in a swine model. Surg Endosc 2010; 25:737-48. [DOI: 10.1007/s00464-010-1244-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2010] [Accepted: 07/05/2010] [Indexed: 10/19/2022]
|
14
|
Beldi G, Wagner M, Bruegger LE, Kurmann A, Candinas D. Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation. Surg Endosc 2010; 25:749-55. [DOI: 10.1007/s00464-010-1246-0] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2010] [Accepted: 07/08/2010] [Indexed: 12/01/2022]
|
15
|
Laparoscopic repair of incisional hernias located on the abdominal borders: a retrospective critical review. Surg Laparosc Endosc Percutan Tech 2009; 19:348-52. [PMID: 19692890 DOI: 10.1097/sle.0b013e3181aa869f] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The aim of this study was to assess feasibility and results of laparoscopic approach to repair incisional hernias of the abdominal borders, the weakest points of abdominal wall. METHODS Since 2002 through 2008 a total of 39 patients with fascial defects of the abdominal borders underwent laparoscopic repair. The defects were suprapubic (n=18), subxiphoidal (n=15), and lateral sided (n=6). The body mass index was >oe=30 Kg/m2 in 19 patients. The parietal defects was measured both externally and from within the peritoneal cavity and 56% of meshes were fixed only by tacks, especially in suprapubic site. RESULTS The mean operating time was 161.8+/-25 minutes. There was 1 intraoperative complication, an intestinal injury repaired laparoscopically. Conversion was needed in 1 patient for massive adhesions. Postoperative early surgical complications were 7 (1 seroma). Morbidity in obese and nonobese patients showed no statistically relevant difference (P>0.05). There was no postoperative death. Mean hospital stay was 5.1+/-3 days. The mean follow-up was 37 months and recurrence was observed in 3 cases. CONCLUSIONS The onlay laparoscopic approach for repair of incisional hernias of the abdominal borders can warrant good results. Obesity is not a contraindication to laparoscopic repair. Anyway, further experiences are necessary to confirm these results.
Collapse
|
16
|
Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model. Surg Endosc 2009; 23:2809-15. [PMID: 22219021 DOI: 10.1007/s00464-009-0509-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2008] [Revised: 03/18/2009] [Accepted: 04/19/2009] [Indexed: 10/20/2022]
Abstract
BACKGROUND In recent years, the use of fibrin glue has become an established practice in several areas of surgical treatment. For example, fibrin glue is used increasingly as an alternative method for mesh fixation in hernia surgery, significantly helping to reduce the incidence of chronic pain. The experiments in this study were aimed at elucidating the extent to which tack- or suture-based permanent fixation can be replaced by fixation with fibrin glue for laparoscopic intraperitoneal repair of abdominal wall hernias. METHODS In an initial series of experiments conducted with a biomechanical model, the strength of the fibrin glue for fixation of lightweight mesh (TiMesh light) to muscle tissue was compared with its strength of fixation to the peritoneum. In a second series of experiments, mesh was laparoscopically implanted in an established porcine model. Fibrin glue was used for mesh fixation in six animals. Laparoscopic exploration and explantation of the meshes were conducted after 4 months. Planimetric analysis was performed to investigate adhesion and shrinkage of the mesh surface. RESULTS The strength of fibrin glue for fixation of mesh to the peritoneum was significantly less than for its fixation to muscle tissue (11.86 N vs. 47.88 N; p = 0.001). Three of the implanted meshes were not completely integrated, and two of these were dislocated. On the average, adhesions were seen on 16% of the mesh surfaces. The mesh shrinkage rate was 24.2%. CONCLUSION Mesh fixation alone to the undamaged peritoneum in the intraperitoneal region cannot be recommended because of the risk for dislocation. Additional fixation using sutures, tacks, or both is needed until the mesh material is completely integrated.
Collapse
|
17
|
Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD. 120-Day Comparative Analysis of Adhesion Grade and Quantity, Mesh Contraction, and Tissue Response to a Novel Omega-3 Fatty Acid Bioabsorbable Barrier Macroporous Mesh After Intraperitoneal Placement. Surg Innov 2008; 16:46-54. [DOI: 10.1177/1553350608330479] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose. This study aimed to evaluate adhesion formation, mesh contraction, and tissue response to an omega-3 fatty acid barrier—coated lightweight polypropylene mesh (C-Qur) after intra-abdominal placement, and compare these properties to those of other commercially available meshes. Materials and methods. After randomization, 3 × 3 cm pieces of Atrium C-Qur, Mesh ProLite Ultra, Composix, Parietex, Proceed, Sepramesh, and DualMesh were sewn to the intact peritoneum on either side of a midline incision in 41 New Zealand white rabbits. Necropsy was performed at 120 days, and explants were evaluated for adhesion grade, adhesion amount, and mesh contraction. Histologic evaluation included extent of capsule formation, abdominal wall tissue ingrowth, degrees of inflammation and vascularization of the surrounding tissue, and the presence of mesothelialization. Results. There were no significant differences between the C-Qur mesh and the commercially available meshes tested with regard to adhesion grade or amount, although percentage adhesion coverage for the C-Qur mesh was much less than for Composix and Proceed. The C-Qur mesh contracted less than all meshes, significantly less ( P < .05) than DualMesh or Proceed. DualMesh exhibited the greatest amount of capsule formation and inflammation on its parietal side as compared with the other meshes. Conclusions. Placing lightweight polypropylene mesh with an omega-3 fatty acid barrier coating intraperitoneally results in more favorable adhesion characteristics compared with Composix and Proceed meshes at 120-day explantation after intraperitoneal placement. The minimal amount of contraction and favorable tissue response in comparison to other commercially available meshes makes C-Qur mesh a practical alternative for laparoscopic and open ventral hernia repair.
Collapse
Affiliation(s)
- Richard A. Pierce
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri
| | - Juan M. Perrone
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri
| | - Abdelrahman Nimeri
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri
| | - Jennifer A. Sexton
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri
| | - Julie Walcutt
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri
| | - Margaret M. Frisella
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri
| | - Brent D. Matthews
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, Saint Louis, Missouri,
| |
Collapse
|
18
|
The use of composite meshes in laparoscopic repair of abdominal wall hernias: are there differences in biocompatibily? Surg Endosc 2008; 23:487-95. [DOI: 10.1007/s00464-008-0085-8] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2008] [Accepted: 06/25/2008] [Indexed: 12/15/2022]
|
19
|
Ferrari GC, Miranda A, Sansonna F, Magistro C, Di Lernia S, Maggioni D, Franzetti M, Pugliese R. Laparoscopic management of incisional hernias > or = 15 cm in diameter. Hernia 2008; 12:571-6. [PMID: 18688567 DOI: 10.1007/s10029-008-0410-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2008] [Accepted: 06/19/2008] [Indexed: 12/30/2022]
Abstract
BACKGROUND Despite good results in terms of safety and minimal recurrence ensured by laparoscopy in the management of incisional hernias, the use of minimally invasive techniques for large incisional wall defects is still controversial. METHODS Between 2002 and 2008 as many as 36 patients with abdominal wall defects > or = 15 cm were managed laparoscopically in our institution. The wall defects were > or = 20 cm in eight cases. The diameter of parietal defects was measured from within the peritoneal cavity. None had loss of domain. Body mass index (BMI) for 18 patients was > or = 30 kg/m(2). RESULTS The mean duration of operations was 195 +/- 28 min (range 75-540). One patient needed conversion for ileal injury and massive adhesions. Post-operative complications occurred in nine patients; there were six surgical complications. Morbidity in obese and non-obese patients was not statistically different (p > 0.05). There was no postoperative death. Mean hospital stay was 4.97 +/- 3.4 days (range 2-18). Mean follow up was 28 months (range 2-68) and only one hernia recurrence was observed. CONCLUSIONS Minimum-access procedures can provide good results in the repair of giant incisional hernia. Obesity is not a contraindication to laparoscopic repair. Further studies are expected to confirm our promising results.
Collapse
Affiliation(s)
- G C Ferrari
- Surgery and Videolaparoscopy Department, Niguarda Hospital, Milan, Piazza Ospedale Maggiore 3, 20162, Milan, Italy
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Ceccarelli G, Patriti A, Batoli A, Bellochi R, Spaziani A, Pisanelli MC, Casciola L. Laparoscopic Incisional Hernia Mesh Repair with the “Double-Crown” Technique: A Case-Control Study. J Laparoendosc Adv Surg Tech A 2008; 18:377-82. [DOI: 10.1089/lap.2007.0121] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Graziano Ceccarelli
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| | - Alberto Patriti
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| | - Alberto Batoli
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| | - Raffaele Bellochi
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| | - Alessandro Spaziani
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| | - Massimo Codacci Pisanelli
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| | - Luciano Casciola
- Department of General, Vascular, Minimally Invasive and Robotic Surgery, San Matteo degli Infermi Hospital, Spoleto, Italy
| |
Collapse
|
21
|
Losanoff JE, Basson MD, Laker S, Weiner M, Webber JD, Gruber SA. Sutured laparoscopic mesh fixation. Surg Endosc 2008; 22:804-5. [PMID: 17593445 DOI: 10.1007/s00464-007-9433-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
22
|
Mesh repair of common abdominal hernias: a review on experimental and clinical studies. Hernia 2008; 12:337-44. [PMID: 18351432 DOI: 10.1007/s10029-008-0362-4] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2007] [Accepted: 02/29/2008] [Indexed: 01/06/2023]
Abstract
Results on hernia surgery from numerous centers confirm that tensionless repair with various meshes reduces the complication rates and the frequency of recurrences. Some evidence on incisional hernias suggests, however, that the use of mesh seems to transfer the onset of recurrences by several years. Persistent pain and other discomfort is also an unpleasant complication of otherwise successful surgery in a number of patients. Thus, improved, slowly degrading, mesh materials, with strong connective tissue-inducing action, might be more optimal for hernia surgery. Accumulating evidence also suggests that recurrent hernias appear in patients having inherited weakness of connective tissues. Numerous tissue specific collagens, in addition to the classical fibrillar I-III collagens and numerous substrate specific matrix proteinases, have recently been described in biochemical literature, and their roles as possible causes of tissue weakness are discussed.
Collapse
|
23
|
Cortes RA, Miranda E, Lee H, Gertner ME. Biomaterials and the Evolution of Hernia Repair II: Composite Meshes. Surgery 2008. [DOI: 10.1007/978-0-387-68113-9_112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2023]
|
24
|
Binnebösel M, Rosch R, Junge K, Flanagan TC, Schwab R, Schumpelick V, Klinge U. Biomechanical analyses of overlap and mesh dislocation in an incisional hernia model in vitro. Surgery 2007; 142:365-71. [PMID: 17723888 DOI: 10.1016/j.surg.2007.04.024] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2006] [Revised: 04/05/2007] [Accepted: 04/09/2007] [Indexed: 11/29/2022]
Abstract
BACKGROUND Incisional hernia repair is one of the most common surgical complications. Despite the introduction of mesh techniques of repair, recurrences are still prevalent. The aim of the current study was to evaluate the dependence of mesh dislocation on defect size, facial overlap, mesh-position, and orientation of the mesh in cases of anisotropic stretchability. METHODS An in vitro incisional hernia model was used, which consisted of a pressure chamber, an elastic silicone pad representing the peritoneal sac, and a silicone mat with bovine muscle tissue representing the abdominal wall. Intrinsic pressure (up to 200 mm Hg) was generated within the pressure chamber by continuous inflation with CO(2). A slit-like or flap-like defect was created in the silicone mat to simulate small or large hernia defects, respectively. The implanted mesh was arranged in both onlay and sublay configurations. A large pore polypropylene mesh with significant anisotropic stretchability was investigated, whereas overlaps of 2, 3, and 4 cm were applied. RESULTS Despite the application of pressures up to 200 mm Hg, no mesh ruptures occurred. In the slit-like defect model, the minimal overlap required to prevent dislocation at 200 mm Hg was 3 cm using the sublay technique provided that the mesh was positioned with its most stretchable axis parallel to the largest slit dehiscence. Perpendicular rotation of the mesh resulted in dislocation at 160 mm Hg, despite using an overlap of 3 cm. Mesh reinforcement showed less stability in both the onlay position and the flap-like defect. CONCLUSION An overlap of 3 cm is sufficient to prevent early mesh dislocation. Meshes with anisotropic stretchability should be orientated with the most stretchable axis in the direction of least overlap.
Collapse
Affiliation(s)
- Marcel Binnebösel
- Department of Surgery, RWTH Aachen University Hospital, Aachen, Germany.
| | | | | | | | | | | | | |
Collapse
|
25
|
Muysoms FE, Cathenis KKJ, Claeys DAB. "Suture hernia": identification of a new type of hernia presenting as a recurrence after laparoscopic ventral hernia repair. Hernia 2006; 11:199-201. [PMID: 17119854 DOI: 10.1007/s10029-006-0170-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2006] [Accepted: 10/19/2006] [Indexed: 11/29/2022]
Abstract
After laparoscopic repair of ventral or incisional hernias, the recurrence rates reported are around 4%. Different mechanisms for the recurrences have been identified. We report two cases in which the patients were operated on laparoscopically for recurrence after laparoscopic ventral hernia repair. In both cases, the site of the recurrent hernia was situated at the transfascial fixation sutures. Patients were treated by laparoscopy with a larger intraperitoneal mesh covering the new hernia and the old mesh.
Collapse
Affiliation(s)
- F E Muysoms
- Department of Surgery, AZ Maria Middelares, Kortrijksesteenweg 1026, Gent, Belgium.
| | | | | |
Collapse
|
26
|
Memisoglu K, Saribeyoglu K, Pekmezci S, Karahasanoglu T, Sen B, Bayrak I, Arbak S, Sirvanci S. Mesh Fixation Devices and Formation of Intraperitoneal Adhesions. J Laparoendosc Adv Surg Tech A 2006; 16:439-44. [PMID: 17004865 DOI: 10.1089/lap.2006.16.439] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
PURPOSE To investigate the effect of mesh fixation devices on the formation of intra-abdominal adhesions. MATERIALS AND METHODS Fourteen New Zealand rabbits were used. In seven animals, nickel-titanium (nitinol) anchors (group 1) and titanium tacks (group 2) were applied by laparoscopy on the right and left sides of the abdomen, respectively. In the remaining seven rabbits, the same devices were applied on prosthetic meshes (groups 3 and 4, respectively). On day 30, the rabbits were sacrificed and macroscopic adhesion scoring was performed. All the specimens were assessed by scanning electron microscopy (SEM). RESULTS All parameters of adhesion except extension were significantly higher in group 4 than group 3 (P < 0.05). Comparisons of group 1 vs. group 2 were not statistically significant (P > 0.05). All the comparisons between a nonmesh group and a mesh group resulted in significant differences. SEM results revealed that the mesothelial cell layer and connective tissue intensively covered the tacks in group 2 whereas no similar findings were observed in group 1. Comparable appearances were encountered in groups 3 and 4. CONCLUSION The nitinol anchor is associated with an acceptable level of adhesion formation and its intraperitoneal use can be considered safe in this regard.
Collapse
Affiliation(s)
- Kemal Memisoglu
- Fatih Sultan Mehmet Training and Research Hospital, Istanbul, Turkey.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Fourtanier G, Muscari F, Duffas JP, Suc B. [Laparocopic repair of incisional hernias: a gold standard?]. ACTA ACUST UNITED AC 2006; 131:233-5. [PMID: 16580623 DOI: 10.1016/j.anchir.2006.01.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
28
|
Agrawal A, Avill R. Mesh migration following repair of inguinal hernia: a case report and review of literature. Hernia 2005; 10:79-82. [PMID: 16258705 DOI: 10.1007/s10029-005-0024-8] [Citation(s) in RCA: 106] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2005] [Accepted: 06/27/2005] [Indexed: 12/11/2022]
Abstract
New surgical procedures in the aftermath of their benefits beget new complications as well. Laparoscopic repair of inguinal hernia is widely practised now. It involves reinforcement of hernial defect with a synthetic mesh. We report a rare case of migration of mesh into urinary bladder following this mode of hernial repair. We also present a review of literature involving migration of mesh following all inguinal hernial repairs.
Collapse
Affiliation(s)
- A Agrawal
- Professorial Unit of Surgery, Nottingham City Hospital, NG5 1PB, Nottingham, UK
| | | |
Collapse
|
29
|
Perrone JM, Soper NJ, Eagon JC, Klingensmith ME, Aft RL, Frisella MM, Brunt LM. Perioperative outcomes and complications of laparoscopic ventral hernia repair. Surgery 2005; 138:708-15; discussion 715-6. [PMID: 16269300 DOI: 10.1016/j.surg.2005.06.054] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2005] [Revised: 06/09/2005] [Accepted: 06/14/2005] [Indexed: 10/25/2022]
Abstract
BACKGROUND Laparoscopic techniques are being used increasingly in the repair of ventral hernias and offer the potential benefits of a shorter hospital stay, decreased wound complications, and possibly a lower recurrence rate. Despite good results from high-volume centers, significant complications may occur with this approach and the morbidity of incisional hernia repair may be underestimated. The purpose of this study was to review our experience with laparoscopic ventral hernia repair (LVHR) since its inception at our institution. METHODS Medical records of all patients who underwent LVHR at a single institution from May 2000 through December 2003 were reviewed. Preoperative and postoperative variables including complications were analyzed. Follow-up evaluation was by office visit and phone survey with assessment of patient satisfaction scores. Data are expressed as mean +/- SD. RESULTS A total of 121 LVHR were performed in 116 patients (52 men, 64 women; mean age, 57 +/- 13 y; mean body mass index, 35 +/- 8). Hernias were recurrent in 35 cases (28.9%), with a mean of 1.4 prior repairs (range, 1-7). The mean defect size was 109 +/- 126 cm2 and the average mesh size used was 256 +/- 192 cm2. Operating time was 147 +/- 45 minutes, and the hospital stay averaged 1.7 +/- 1 days. Twelve cases (9.9%) were converted to open operation, most commonly because of extensive adhesions. Extensive laparoscopic adhesiolysis was necessary in 29 cases (26.6%). Overall, perioperative complications occurred in 33 cases (27.3%), 13 of which (39.3%) were persistent seromas. Major complications were seen in 9 cases (7.4%). There were 4 enterotomies (3.3%): 3 occurred as a result of adhesiolysis and 1 resulted from a trocar injury; 2 were detected intraoperatively and were converted to open operation and 2 presented postoperatively. One of these patients developed sepsis and died. Follow-up evaluation was available for 83.6% of cases at a mean interval of 22 +/- 16 months after repair. The hernia recurrence rate was 9.3% (9 cases) and was detected at a median of 6 months postoperatively. The overall patient satisfaction score was high at 4.3 +/- 1.1 (scale, 1-5). CONCLUSIONS Laparoscopic repair is effective for the vast majority of patients with primary or recurrent ventral hernias and results in hernia recurrence rates of less than 10%, with high patient satisfaction scores. Although seroma is the most common complication, major morbidity occurred in 7.4% of the patients in our series. Enterotomy is the most common serious complication and may result in sepsis and death.
Collapse
Affiliation(s)
- Juan M Perrone
- Department of Surgery and Institute for Minimally Invasive Surgery, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | | | | | | | | | | | | |
Collapse
|