1
|
Ji Y, Zhuo Y, Li T, Lian J, Wang Z, Guo X, Kong D, Li K. MR-guided percutaneous microwave coagulation of small breast tumors. Insights Imaging 2024; 15:76. [PMID: 38499835 PMCID: PMC10948645 DOI: 10.1186/s13244-024-01645-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 02/10/2024] [Indexed: 03/20/2024] Open
Abstract
BACKGROUND To evaluate the technical success and patient safety of magnetic resonance-guided percutaneous microwave coagulation (MR-guided PMC) for breast malignancies. METHODS From May 2018 to December 2019, 26 patients with breast tumors measuring 2 cm or less were recruited to participate in a prospective, single-institution clinical study. The primary endpoint of this study was the evaluation of treatment efficacy for each patient. Histochemical staining with α-nicotinamide adenine dinucleotide and reduced (NADH)-diaphorase was used to determine cell viability following and efficacy of PMC. The complications and self-reported sensations from all patients during and after ablation were also assessed. The technical success of the PMC procedure was defined when the area of the NADH-diaphorase negative region fully covered the hematoxylin-eosin (H&E) staining region in the tumor. RESULTS All patients had a complete response to ablation with no residual carcinoma on histopathological specimen. The mean energy, ablation duration, and procedure duration per tumor were 36.0 ± 4.2 kJ, 252.9 ± 30.9 S, and 104.2 ± 13.5 min, respectively. During the ablation, 14 patients underwent prolonged ablation time, and 1 patient required adjusting of the antenna position. Eleven patients had feelings of subtle heat or swelling, and 3 patients experienced slight pain. After ablation, one patient took two painkillers because of moderate pain, and no patients had postoperative oozing or other complications after PMC. Induration around the ablation area appeared in 16 patients. CONCLUSION MR-guided PMC of small breast tumors is feasible and could be applied in clinical practice in the future. CRITICAL RELEVANCE STATEMENT MR-guided PMC of small breast tumors is feasible and could be applied in clinical practice in the future. KEY POINTS • MR-guided PMC of small breast tumors is feasible. • PMC was successfully performed for all patients. • All patients were satisfied with the final cosmetic result.
Collapse
Affiliation(s)
- Ying Ji
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Yaoyao Zhuo
- Department of Radiology, Zhongshan Hospital, Fudan University School of Medicine, Shanghai, 200000, China
| | - Ting Li
- Department of Radiology, First People's Hospital of Changzhou, Jiangsu, 213003, China
| | - Jingge Lian
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Zilin Wang
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Xinyu Guo
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Dexing Kong
- School of Mathematical Sciences, Zhejiang University, Zhejiang, 310027, China
| | - Kangan Li
- Department of Radiology, Songjiang Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 201600, China.
| |
Collapse
|
2
|
Xu K, Li Z, Wang C, Tian C, Jiao D, Han X, Yan Y. 3.0-T closed MR-guided microwave ablation for HCC located under the hepatic dome: a single-center experience. Int J Hyperthermia 2022; 39:1044-1051. [PMID: 35940593 DOI: 10.1080/02656736.2022.2107717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022] Open
Abstract
PURPOSE To analyze the clinical safety and efficacy of 3.0-T closed MR-guided microwave ablation (MWA) for the treatment of HCC located under the hepatic dome. METHODS From May 2018 to October 2020, 49 patients with 74 HCCs located under the hepatic dome underwent MWA using 3.0-T closed MR guidance. The technical success rate, operative time, complete ablation (CA) rate, complications, local tumor progression (LTP), tumor-free survival (TFS) and overall survival (OS) were examined. Routine blood analysis, liver/kidney function and alpha fetoprotein (AFP) and protein induced by vitamin k absent or antagonist (PIVKA) levels were compared before and 2 months after MWA. RESULTS All patients underwent MWA successfully, including 10 patients who underwent general anesthesia. The technical success rate was 100% without major complications. The CA rate was 95.9% (71/74) at the 2-month evaluation. The LTP rate was 2.7% during the median follow-up of 17.8 months (range: 4-43 months); the 6-, 12-, 18-month TFS rates were 97.8, 90.6, 68.1%, respectively, and the 6-, 12-, 18-month OS rates were 100, 97.6, 92.1%, respectively. There were no significant changes in routine blood tests and liver/kidney function (p > 0.05), while the AFP and PIVKA level decreased significantly at 2 months (p < 0.05). CONCLUSION 3.0-T MR-guided MWA is safe and feasible for HCC lesions located under the hepatic dome.
Collapse
Affiliation(s)
- Kaihao Xu
- Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Zhaonan Li
- Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Chaoyan Wang
- Department of Magnetic Resonance, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Chuan Tian
- Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Dechao Jiao
- Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Xinwei Han
- Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Yan Yan
- Department of Oncology, First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| |
Collapse
|
3
|
2450-MHz microwave ablation of liver metastases under 3.0 T wide-bore magnetic resonance guidance: a pilot study. Sci Rep 2022; 12:12640. [PMID: 35879411 PMCID: PMC9314346 DOI: 10.1038/s41598-022-16989-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 07/19/2022] [Indexed: 11/29/2022] Open
Abstract
To investigate the feasibility and effectiveness of 3.0 T wide-bore magnetic resonance (MR)-guided microwave ablation (MA) of liver metastases (LM). From October 2018 to May 2020, 39 patients with 63 LM were treated with 3.0 T wide-bore MR-guided 2450-MHz MA therapy. The procedure parameters, technical success, complications, biochemical index changes, local tumor response, local tumor progression (LTP), 12-month disease-free survival (DFS) and 12-month overall survival (OS) were recorded and analyzed. The mean tumor maximum diameter and total procedure time were 3.0 cm and 55.2 min, respectively. Technical success was 100%, but 5 cases (12.8%) had grade-1 complications. Alanine transaminase, aspartate transaminase and total bilirubin showed a slight transient increase on day 3 (P < 0.05) and returned to normal by day 30 (P > 0.05). The complete ablation rates for ≤ 2.5 and > 2.5 cm lesions were 100% and 92.5%, respectively. During the median follow-up of 12.0 months, the LTP rate was 4.8% (3/63), and the 12-month DFS and OS rates were 61.3% and 92.2%, respectively. 3.0 T wide-bore MR-guided MA for LM is a safe and effective approach, especially for small LM.
Collapse
|
4
|
Schneider C, Allam M, Stoyanov D, Hawkes DJ, Gurusamy K, Davidson BR. Performance of image guided navigation in laparoscopic liver surgery - A systematic review. Surg Oncol 2021; 38:101637. [PMID: 34358880 DOI: 10.1016/j.suronc.2021.101637] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 07/04/2021] [Accepted: 07/24/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Compared to open surgery, minimally invasive liver resection has improved short term outcomes. It is however technically more challenging. Navigated image guidance systems (IGS) are being developed to overcome these challenges. The aim of this systematic review is to provide an overview of their current capabilities and limitations. METHODS Medline, Embase and Cochrane databases were searched using free text terms and corresponding controlled vocabulary. Titles and abstracts of retrieved articles were screened for inclusion criteria. Due to the heterogeneity of the retrieved data it was not possible to conduct a meta-analysis. Therefore results are presented in tabulated and narrative format. RESULTS Out of 2015 articles, 17 pre-clinical and 33 clinical papers met inclusion criteria. Data from 24 articles that reported on accuracy indicates that in recent years navigation accuracy has been in the range of 8-15 mm. Due to discrepancies in evaluation methods it is difficult to compare accuracy metrics between different systems. Surgeon feedback suggests that current state of the art IGS may be useful as a supplementary navigation tool, especially in small liver lesions that are difficult to locate. They are however not able to reliably localise all relevant anatomical structures. Only one article investigated IGS impact on clinical outcomes. CONCLUSIONS Further improvements in navigation accuracy are needed to enable reliable visualisation of tumour margins with the precision required for oncological resections. To enhance comparability between different IGS it is crucial to find a consensus on the assessment of navigation accuracy as a minimum reporting standard.
Collapse
Affiliation(s)
- C Schneider
- Department of Surgical Biotechnology, University College London, Pond Street, NW3 2QG, London, UK.
| | - M Allam
- Department of Surgical Biotechnology, University College London, Pond Street, NW3 2QG, London, UK; General surgery Department, Tanta University, Egypt
| | - D Stoyanov
- Department of Computer Science, University College London, London, UK; Centre for Medical Image Computing (CMIC), University College London, London, UK
| | - D J Hawkes
- Centre for Medical Image Computing (CMIC), University College London, London, UK; Wellcome / EPSRC Centre for Surgical and Interventional Sciences (WEISS), University College London, London, UK
| | - K Gurusamy
- Department of Surgical Biotechnology, University College London, Pond Street, NW3 2QG, London, UK
| | - B R Davidson
- Department of Surgical Biotechnology, University College London, Pond Street, NW3 2QG, London, UK
| |
Collapse
|
5
|
Lin Z, Chen J, Yan Y, Chen J, Li Y. Microwave ablation of hepatic malignant tumors using 1.5T MRI guidance and monitoring: feasibility and preliminary clinical experience. Int J Hyperthermia 2020; 36:1216-1222. [PMID: 31814474 DOI: 10.1080/02656736.2019.1690166] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Purpose: To evaluate the feasibility and therapeutic efficacy of 1.5-T MRI-guided and monitored microwave ablation in patients with hepatic malignant tumors.Materials and Methods: This retrospective study was approved by the ethics committee of the First Affiliated Hospital of Fujian Medical University. Thirty-five patients (32 men, three women) with 48 lesions (maximum diameter < 3 cm) underwent microwave ablation under the guidance and monitoring of a 1.5-T MRI. The MRI-compatible microwave generator was appended with a magnetic shield case, and the cable was combined with a choke coil for shielding the Larmor processing frequency. The average age of the patients was 56.51 ± 11.36 years (31-77 years). Twenty-eight patients (37 lesions) displayed hepatocellular carcinoma and seven patients (11 lesions) had metastatic liver carcinoma. The mean maximum tumor diameter was 12.31 ± 4.72 mm (range 5.0-25.7 mm).Results: MRI scans were performed simultaneously without electromagnetic interference during ablation. The average maximum diameter of the hypointense zone of the last monitored T2WI sequence, hypointense zone of post-procedure T2WI sequence, and hyperintense zone of post-procedure T1WI were 28.82 ± 7.58 mm, 29.79 ± 7.91 mm, and 28.28 ± 8.37 mm, respectively, with no observed statistical difference (F = 0.434, p = .649). The technical success rate was 100%. The average follow-up duration was 11.43 ± 5.29 (4-33) months. The technique efficacy rate was 100%.Conclusion: MRI-guided and monitored microwave ablation of hepatic malignant tumors is feasible and potentially safe and effective.Key pointsMRI-guided microwave ablation of hepatic malignant tumors is feasible.The MRI monitoring scan could accurately reflect the scope of ablation lesion.On T1WI, the ablation lesions of liver showed the 'target sign'.
Collapse
Affiliation(s)
- Zhengyu Lin
- The Department of Interventional Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Jin Chen
- The Department of Interventional Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Yuan Yan
- The Department of Interventional Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Jian Chen
- The Department of Interventional Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Yuliang Li
- The Department of Interventional Radiology, The Second Hospital of Shandong University, Jinan, China
| |
Collapse
|
6
|
Santambrogio R, Barabino M, D'Alessandro V, Galfrascoli E, Zappa MA, Piccolo G, Zuin M, Opocher E. Laparoscopic thermoablation for hepatocellular carcinoma in patients with liver cirrhosis: an effective procedure for tricky tumors. Med Oncol 2020; 37:32. [PMID: 32193636 DOI: 10.1007/s12032-020-1342-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Accepted: 01/28/2020] [Indexed: 12/23/2022]
Abstract
The optimal treatment for hepatocellular carcinoma (HCC) is surgical resection. However, only a small percentage of patients are amenable to this option. Percutaneous radiofrequency interstitial thermal ablation (TA) proved to be effective in the treatment of unresectable HCC. Recent advances in laparoscopic ultrasound have improved the accuracy in detecting small intrahepatic HCC nodules missed by pre-operative imaging techniques. Our objective was to evaluate an operative combination of laparoscopic ultrasound with laparoscopic thermoablation (LTA) in the treatment of HCC not amenable to liver resection. The aim of our review was to evaluate the advantages and limits of the laparoscopic approach according the criteria of the evidence-based medicine. LTA of HCC proved to be a safe and effective technique both in the short- and long-term follow-up period. This technique may be indicated in selected cases when the percutaneous approach to the lesion is very difficult or contraindicated.
Collapse
Affiliation(s)
| | - Matteo Barabino
- Hepatobiliary Surgery Unit, Department of Surgery, San Paolo Hospital, University of Milan, Via Di Rudinì 8, 20142, Milan, Italy.
| | | | | | | | - Gaetano Piccolo
- Hepatobiliary Surgery Unit, Department of Surgery, San Paolo Hospital, University of Milan, Via Di Rudinì 8, 20142, Milan, Italy
| | - Massimo Zuin
- Hepato-Gastroenterology Unit, San Paolo Hospital, University of Milan, Milan, Italy
| | - Enrico Opocher
- Hepatobiliary Surgery Unit, Department of Surgery, San Paolo Hospital, University of Milan, Via Di Rudinì 8, 20142, Milan, Italy
| |
Collapse
|
7
|
Yamada A, Tokuda J, Naka S, Murakami K, Tani T, Morikawa S. Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator. Med Phys 2019; 47:850-858. [PMID: 31829440 DOI: 10.1002/mp.13958] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 12/06/2019] [Accepted: 12/06/2019] [Indexed: 12/23/2022] Open
Abstract
PURPOSE Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is preferable due to its superior soft tissue contrast. The objective of this study was to develop and evaluate an MR and US multi-modal image-guided navigation system with a needle manipulator to enable US-guided applicator placement during MR imaging (MRI)-guided percutaneous tumor ablation. METHODS The MRI-compatible needle manipulator with US probe was installed adjacent to a 3 Tesla MRI scanner patient table. Coordinate systems for the MR image, patient table, manipulator, and US probe were all registered using an optical tracking sensor. The patient was initially scanned in the MRI scanner bore for planning and then moved outside the bore for treatment. Needle insertion was guided by real-time US imaging fused with the reformatted static MR image to enhance soft tissue contrast. Feasibility, targeting accuracy, and MR compatibility of the system were evaluated using a bovine liver and agar phantoms. RESULTS Targeting error for 50 needle insertions was 1.6 ± 0.6 mm (mean ± standard deviation). The experiment confirmed that fused MR and US images provided real-time needle localization against static MR images with soft tissue contrast. CONCLUSIONS The proposed MR and US multi-modal image-guided navigation system using a needle manipulator enabled accurate needle insertion by taking advantage of static MR and real-time US images simultaneously. Real-time visualization helped determine needle depth, tissue monitoring surrounding the needle path, target organ shifts, and needle deviation from the path.
Collapse
Affiliation(s)
- Atsushi Yamada
- Department of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan
| | - Junichi Tokuda
- National Center for Image Guided Therapy, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, 02115, USA
| | - Shigeyuki Naka
- Department of Surgery, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan
| | - Koichiro Murakami
- Department of Surgery, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan
| | - Tohru Tani
- Department of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan
| | - Shigehiro Morikawa
- Molecular Neuroscience Research Center, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan
| |
Collapse
|