1
|
Fendrych K, Porada R, Baś B. Electrochemical sensing platform based on Zeolite/Graphite/Dimethylglyoxime nanocomposite for highly selective and ultrasensitive determination of nickel. JOURNAL OF HAZARDOUS MATERIALS 2023; 448:130953. [PMID: 36860040 DOI: 10.1016/j.jhazmat.2023.130953] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/23/2023] [Accepted: 02/04/2023] [Indexed: 06/18/2023]
Abstract
In this work, the fabrication and analytical application of a novel, unique, mercury-free, and user-friendly voltammetric sensor of Ni(II) based on glassy carbon electrode (GCE) modified with zeolite(MOR)/graphite(G)/dimethylglyoxime(DMG) composite (MOR/G/DMG-GCE) and the voltammetric procedure for highly selective, ultra-trace determination of nickel ions were reported for the first time. Deposition of a thin layer of the chemically active MOR/G/DMG nanocomposite enables the selective and effective accumulation of Ni(II) ions in the form of the DMG-Ni(II) complex. In 0.1 mol L-1 ammonia buffer (pH 9.0), the MOR/G/DMG-GCE exhibited linear response in the Ni(II) ions concentration range of 0.86 - 19.61 µg L-1 and 0.57 - 15.75 µg L-1, for the accumulation time of 30 s and 60 s, respectively. For 60 s of accumulation time, the limit of detection (S/N = 3) was 0.18 µg L-1 (3.04 nM), and sensitivity of 0.202 µA L µg-1 was achieved. The developed protocol was validated by the analysis of wastewater certified reference materials. Its practical usefulness was confirmed by the determination of nickel released from metallic jewelry submerged in artificial sweat and stainless steel pot during water boiling. The obtained results were verified by electrothermal atomic absorption spectroscopy as a reference method.
Collapse
Affiliation(s)
- Katarzyna Fendrych
- Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, Kraków 30-059, Poland.
| | - Radosław Porada
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, Kraków 30-387, Poland
| | - Bogusław Baś
- Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, Kraków 30-059, Poland
| |
Collapse
|
2
|
Rahmati N, Rahimnejad M, Pourali SM, Muallah SK. Bismuth Oxychloride Nanoparticles: Deep Eutectic Solvent Assisted Synthesis and Application in an Electrochemical Nickel Sensor. ChemistrySelect 2022. [DOI: 10.1002/slct.202202430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Neda Rahmati
- Biofuel & Renewable Energy Research Center Faculty of Chemical Engineering Babol Noshirvani University of Technology Babol Iran
| | - Mostafa Rahimnejad
- Biofuel & Renewable Energy Research Center Faculty of Chemical Engineering Babol Noshirvani University of Technology Babol Iran
| | - S. Masoomeh Pourali
- Biofuel & Renewable Energy Research Center Faculty of Chemical Engineering Babol Noshirvani University of Technology Babol Iran
| | - Shatha K. Muallah
- Department of Biochemical Engineering AlKhawarizmi Engineering College University of Baghdad Baghdad Iraq
| |
Collapse
|
3
|
Bismuth-Chitosan Nanocomposite Sensors for Trace Level Detection of Ni(II) and Co(II) in Water Samples. WATER 2022. [DOI: 10.3390/w14030302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Trace minerals play an essential role in methane production via anaerobic digestion (AD). It is important to monitor Ni(II) and Co(II) concentrations and the Ni/Co concentration ratio for the rapid diagnosis of the ecological status or activity of methanogens in AD. Electrochemical detection of Ni(II) and Co(II) was investigated by coating the Bi-chitosan nanocomposite on a glassy carbon electrode (GCE) via the electrodeposition technique. A square-wave adsorptive cathodic stripping voltammetry technique (SWAdCSV) was applied and optimized when dimethylglyoxime (DMG) was used as the chelating agent for Ni(II) and Co(II) measurements. The SWAdCSV results showed that the current peaks for Co(II) detection are 6.1 times greater than the current peaks for Ni(II) measurements, probably due to the different affinity of DMG molecules between Ni(II) and Co(II). DMG molecules demonstrated higher selectivity toward Co(II) cations compared to Ni(II). The modified Bi-chitosan GCE developed in this study showed a relatively wide range of the Ni(II) and Co(II) concentrations (2–100 µg L−1) with a limit of detection of 3.6 µg L−1 for Ni(II) and 2.4 µg L−1 for Co(II), respectively. The developed sensor was applied to Ni(II) and Co(II) spiked natural water samples and showed good performance of detection with 12 consecutive measurements. Overall, the fabricated sensor showed excellent sensitivity toward Ni(II) and Co(II) in natural water samples.
Collapse
|
4
|
Determination of Trace Levels of Nickel(II) by Adsorptive Stripping Voltammetry Using a Disposable and Low-Cost Carbon Screen-Printed Electrode. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9050094] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A commercial and disposable screen-printed carbon electrode (SPCE) has been proposed for a fast, simple and low-cost determination of Ni(II) at very low concentration levels by differential pulse adsorptive stripping voltammetry (DPAdSV) in the presence of dimethylglyoxime (DMG) as complexing agent. In contrast with previously proposed methods, the Ni(II)-DMG complex adsorbs directly on the screen-printed carbon surface, with no need of mercury, bismuth or antimony coatings. Well-defined stripping peaks and a linear dependence of the peak area on the concentration of Ni(II) was achieved in the range from 1.7 to 150 µg L−1, with a limit of detection of 0.5 µg L−1 using a deposition time of 120 s. An excellent reproducibility and repeatability with 0.3% (n = 3) and 1.5% (n = 15) relative standard deviation, respectively, were obtained. In addition, the suitability of the SPCE as sensing unit has been successfully assessed in a wastewater certificated reference material with remarkable trueness and very good reproducibility.
Collapse
|
5
|
Sun H, Kocaefe D, Bhattacharyay D, Kocaefe Y, Côté J, Coulombe P. Colorimetric Methods for Determining Fe, V, and Ni Contents in Coke and Anodes. Chem Eng Technol 2019. [DOI: 10.1002/ceat.201800205] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Hang Sun
- University of Quebec at ChicoutimiUQAC Research Chair on Industrial Materials (CHIMI) 555, boul. de l'Université G7H 2B1 Chicoutimi (Quebec) Canada
| | - Duygu Kocaefe
- University of Quebec at ChicoutimiUQAC Research Chair on Industrial Materials (CHIMI) 555, boul. de l'Université G7H 2B1 Chicoutimi (Quebec) Canada
| | - Dipankar Bhattacharyay
- University of Quebec at ChicoutimiUQAC Research Chair on Industrial Materials (CHIMI) 555, boul. de l'Université G7H 2B1 Chicoutimi (Quebec) Canada
| | - Yasar Kocaefe
- University of Quebec at ChicoutimiUQAC Research Chair on Industrial Materials (CHIMI) 555, boul. de l'Université G7H 2B1 Chicoutimi (Quebec) Canada
| | - Jules Côté
- University of Quebec at ChicoutimiUQAC Research Chair on Industrial Materials (CHIMI) 555, boul. de l'Université G7H 2B1 Chicoutimi (Quebec) Canada
| | - Patrick Coulombe
- University of Quebec at ChicoutimiUQAC Research Chair on Industrial Materials (CHIMI) 555, boul. de l'Université G7H 2B1 Chicoutimi (Quebec) Canada
| |
Collapse
|
6
|
Mettakoonpitak J, Miller-Lionberg D, Reilly T, Volckens J, Henry CS. Low-Cost Reusable Sensor for Cobalt and Nickel Detection in Aerosols Using Adsorptive Cathodic Square-Wave Stripping Voltammetry. J Electroanal Chem (Lausanne) 2017; 805:75-82. [PMID: 29399008 DOI: 10.1016/j.jelechem.2017.10.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A low-cost electrochemical sensor with Nafion/Bi modification using adsorptive stripping voltammetry for Co and Ni determination in airborne particulate matter and welding fume samples is described. Carbon stencil-printed electrodes (CSPEs) manufactured on low-cost PET films were utilized. Dimethylglyoxime (DMG) was used as a Co(II) and Ni(II) chelator with selective chemical precipitation for trace electrochemical analysis. Electrochemical studies of the Nafion/Bi-modified CSPE indicated a diffusion-controlled redox reaction for Co and Ni measurements. The Nafion coating decreased the background current and enhanced the measured peak current. Repeatability tests based on changes in percent relative standard deviation (RSD) of peak current showed the electrode could be used at least 15 times before the RSD exceeded 15% (the reported value of acceptable repeatability from Association of Official Analytical Chemists (AOAC)) due to deterioration of electrode surface. Limits of detection were 1 μg L-1 and 5 μg L-1 for Co and Ni, respectively, which were comparable to electrochemical sensors requiring more complicated modification procedures. The sensor produced a working range of 1-250 and 5-175 μg L-1 for Co and Ni, respectively. Interference studies showed no other metal species interfered with Co and Ni measurements using the optimized conditions. Finally, the developed sensors were applied for Co and Ni determination in aerosol samples generated from Co rods and a certified welding-fume reference material, respectively. Validation with ICP-MS showed no statistically different results with 95% confidence between sensor and the ICP methods.
Collapse
Affiliation(s)
| | - Dan Miller-Lionberg
- Access Sensor Technologies LLC, 430 N College Ave St. 410, Fort Collins, Colorado 80524, USA
| | - Thomas Reilly
- Access Sensor Technologies LLC, 430 N College Ave St. 410, Fort Collins, Colorado 80524, USA
| | - John Volckens
- Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA
| |
Collapse
|
7
|
Activated biochar: Preparation, characterization and electroanalytical application in an alternative strategy of nickel determination. Anal Chim Acta 2017; 983:103-111. [DOI: 10.1016/j.aca.2017.06.025] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Revised: 05/18/2017] [Accepted: 06/12/2017] [Indexed: 11/24/2022]
|
8
|
Pokpas K, Jahed N, Baker PG, Iwuoha EI. Complexation-Based Detection of Nickel(II) at a Graphene-Chelate Probe in the Presence of Cobalt and Zinc by Adsorptive Stripping Voltammetry. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1711. [PMID: 28757588 PMCID: PMC5580100 DOI: 10.3390/s17081711] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 07/01/2017] [Accepted: 07/03/2017] [Indexed: 11/17/2022]
Abstract
The adsorptive stripping voltammetric detection of nickel and cobalt in water samples at metal film electrodes has been extensively studied. In this work, a novel, environmentally friendly, metal-free electrochemical probe was constructed for the ultra-trace determination of Ni2+ in water samples by Adsorptive Cathodic Stripping Voltammetry (AdCSV). The electrochemical platform is based on the adsorptive accumulation of Ni2+ ions directly onto a glassy carbon electrode (GCE) modified with dimethylglyoxime (DMG) as chelating agent and a Nafion-graphene (NGr) nanocomposite to enhance electrode sensitivity. The nafion-graphene dimethylglyoxime modified glassy carbon electrode (NGr-DMG-GCE) shows superior detection capabilities as a result of the improved surface-area-to-volume ratio and enhanced electron transfer kinetics following the incorporation of single layer graphene, while limiting the toxic effects of the sensor by removal of the more common mercury, bismuth and lead films. Furthermore, for the first time the NGr-DMG-GCE, in the presence of common interfering metal ions of Co2+ and Zn2+ demonstrates good selectivity and preferential binding towards the detection of Ni2+ in water samples. Structural and morphological characterisation of the synthesised single layer graphene sheets was conducted by Raman spectrometry, HRTEM and HRSEM analysis. The instrumental parameters associated with the electrochemical response, including accumulation potential and accumulation time were investigated and optimised in addition to the influence of DMG and graphene concentrations. The NGr-DMG-GCE demonstrated well resolved, reproducible peaks, with RSD (%) below 5% and a detection limit of 1.5 µg L-1 for Ni2+ reduction at an accumulation time of 120 s., the prepared electrochemical sensor exhibited good detection and quantitation towards Ni2+ detection in tap water samples, well below 0.1 mg L-1 set by the WHO and EPA standards. This comparable to the South African drinking water guidelines of 0.15 mg L-1.
Collapse
Affiliation(s)
- Keagan Pokpas
- SensorLab, Department of Chemistry, University of the Western Cape, Bellville 7535, South Africa.
| | - Nazeem Jahed
- SensorLab, Department of Chemistry, University of the Western Cape, Bellville 7535, South Africa.
| | - Priscilla G Baker
- SensorLab, Department of Chemistry, University of the Western Cape, Bellville 7535, South Africa.
| | - Emmanuel I Iwuoha
- SensorLab, Department of Chemistry, University of the Western Cape, Bellville 7535, South Africa.
| |
Collapse
|
9
|
Weldeabzgi A, Reddy DN, Mekonnen KN. Spectrophotometric Determination of Nickel (II) in Soil and Standard Alloy Samples Using 5-Methyl-2-Acetylfuran-4-Methyl-3-Thiosemicarbazone (5-MAFMT). COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS 2017:00103624.2016.1269797. [DOI: https:/doi.org/10.1080/00103624.2016.1269797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2023]
|
10
|
Weldeabzgi A, Reddy DN, Mekonnen KN. Spectrophotometric Determination of Nickel (II) in Soil and Standard Alloy Samples Using 5-Methyl-2-Acetylfuran-4-Methyl-3-Thiosemicarbazone (5-MAFMT). COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS 2017:00103624.2016.1269797. [DOI: 10.1080/00103624.2016.1269797] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2023]
|
11
|
Saciloto TR, Cervini P, Cavalheiro ÉTG. Simultaneous Voltammetric Determination of Zn(II), Pb(II), Cu(II), and Hg(II) in Ethanol Fuel Using an Organofunctionalized Modified Graphite-Polyurethane Composite Disposable Screen-Printed Device. ELECTROANAL 2014. [DOI: 10.1002/elan.201400282] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
12
|
Lima FF, Tormin TF, Richter EM, Munoz RA. Stripping voltammetric determination of manganese in bioethanol. Microchem J 2014. [DOI: 10.1016/j.microc.2014.05.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
13
|
Santos AL, Takeuchi RM, Muñoz RAA, Angnes L, Stradiotto NR. Electrochemical Determination of Inorganic Contaminants in Automotive Fuels. ELECTROANAL 2012. [DOI: 10.1002/elan.201200193] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
14
|
References. Anal Chem 2012. [DOI: 10.1201/b11478-14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Abstract
AbstractIn this review (with 500 refs), both electrochemistry and electroanalysis with carbon paste-based electrodes, sensors, and detectors are of interest, when attention is focused on the research activities in the years of new millennium. Concerned are all important aspects of the field, from fundamental investigations with carbon paste as the electrode material, via laboratory examination of the first electrode prototypes, basic and advanced studies of various electrode processes and other phenomena, up to practical applications to the determination of inorganic ions, complexes, and molecules. The latter is presented in a series of extensive tables, offering a nearly complete survey of methods published within the period of 2001–2008. Finally, the latest trends and outstanding achievements are also outlined and future prospects given.
Collapse
|
16
|
Takeuchi RM, Santos AL, Medeiros MJ, Stradiotto NR. Copper determination in ethanol fuel samples by anodic stripping voltammetry at a gold microelectrode. Mikrochim Acta 2008. [DOI: 10.1007/s00604-008-0039-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
17
|
A solid paraffin-based carbon paste electrode modified with 2-aminothiazole organofunctionalized silica for differential pulse adsorptive stripping analysis of nickel in ethanol fuel. Anal Chim Acta 2006; 584:295-301. [PMID: 17386618 DOI: 10.1016/j.aca.2006.11.069] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2006] [Revised: 11/21/2006] [Accepted: 11/27/2006] [Indexed: 11/27/2022]
Abstract
A solid paraffin-based carbon paste electrode modified with 2-aminothiazole organofunctionalized silica (SiAt-SPCPE) was applied to Ni(2+) determination in commercial ethanol fuel samples. The proposed method comprised four steps: (1) Ni(2+) preconcentration at open circuit potential directly in the ethanol fuel sample, (2) transference of the electrode to an electrochemical cell containing DMG, (3) differential pulse voltammogram registering and (4) surface regeneration by polishing the electrode. The proposed method combines the high Ni(2+) adsorption capacity presented by 2-aminothiazole organofunctionalized silica with the electrochemical properties of the Ni(DMG)(2) complex, whose electrochemical reduction provides the analytical signal. All experimental parameters involved in the proposed method were optimized. Using a preconcentration time of 20 min, it was obtained a linear range from 7.5 x 10(-9) to 1.0 x 10(-6) mol L(-1) with detection limit of 2.0 x 10(-9) mol L(-1). Recovery values between 96.5 and 102.4% were obtained for commercial samples spiked with 1.0 micromol L(-1) Ni(2+) and the developed electrode was totally stable in ethanolic solutions. The contents of Ni(2+) found in the commercial samples using the proposed method were compared to those obtained by graphite furnace atomic absorption spectroscopy by using the F- and t-test. Neither the F- nor t-values exceeded the critical values at 95% confidence level, confirming that there are not statistical differences between the results obtained by both methods. These results indicate that the developed electrode can be successfully employed to reliable Ni(2+) determination in commercial ethanol fuel samples without any sample pretreatment or dilution step.
Collapse
|