1
|
Rozaini MNH, Semail NF, Zango ZU, Lim JW, Yahaya N, Setiabudi HD, Tong WY, Shamsuddin R, Chan YJ, Khoo KS, Suliman M, Kiatkittipong W. Advanced adsorptions of non-steroidal anti-inflammatory drugs from environmental waters in improving offline and online preconcentration techniques: An analytical review. J Taiwan Inst Chem Eng 2025; 166:105020. [DOI: 10.1016/j.jtice.2023.105020] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
|
2
|
Sohrabi Y, Rahimian F, Yousefinejad S, Aliasghari F, Soleimani E. Microextraction techniques for occupational biological monitoring: Basic principles, current applications and future perspectives. Biomed Chromatogr 2024; 38:e5883. [PMID: 38712625 DOI: 10.1002/bmc.5883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 03/01/2024] [Accepted: 04/01/2024] [Indexed: 05/08/2024]
Abstract
The application of green microextraction techniques (METs) is constantly being developed in different areas including pharmaceutical, forensic, food and environmental analysis. However, they are less used in biological monitoring of workers in occupational settings. Developing valid extraction methods and analytical techniques for the determination of occupational indicators plays a critical role in the management of workers' exposure to chemicals in workplaces. Microextraction techniques have become increasingly important because they are inexpensive, robust and environmentally friendly. This study aimed to provide a comprehensive review and interpret the applications of METs and novel sorbents and liquids in biological monitoring. Future perspectives and occupational indicators that METs have not yet been developed for are also discussed.
Collapse
Affiliation(s)
- Younes Sohrabi
- Department of Occupational Health and Safety Engineering, Shoushtar Faculty of Medical Sciences, Shoushtar, Iran
| | - Fatemeh Rahimian
- Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Yousefinejad
- Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Fereshteh Aliasghari
- Department of Clinical Nutrition, School of Nutrition and Food Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Esmaeel Soleimani
- Department of Occupational Health and Safety Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
3
|
Tahmasebi E, Javadi A. Introduction of an electrospun nanofibrous membrane incorporated by metal-organic framework-199 (MOF-199) with Lewis acid property for efficient extraction of sulfonamides in on-chip electromembrane extraction. J Chromatogr A 2024; 1723:464900. [PMID: 38643741 DOI: 10.1016/j.chroma.2024.464900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/24/2024] [Accepted: 04/09/2024] [Indexed: 04/23/2024]
Abstract
In this study, a new supporting polymeric membrane having Lewis acid nature was introduced for immobilizing organic solvent in on-chip electromembrane extraction (on-chip EME). For this aim, a polymeric nanofibrous membrane incorporated by a copper based metal-organic framework (MOF-199), with coordinatively unsaturated metal sites and Lewis acid property, was prepared by electrospinning a mixture of polycaprolactone (PCL) and MOF-199. Based on the field emission scanning electron microscopy images, the obtained polymeric membrane consisted of intertwined nanofibers having empty space between the fibers which could provide a suitable place for immobilizing the organic solvent. To demonstrate remarkable extractability of the proposed membrane (PCL/MOF-199 nanofibers) via executing Lewis acid-base interactions, three sulfonamide drugs was selected as anionic polar analytes with Lewis base feature. The parameters affecting the extraction efficiency of the method were optimized through the experimental design method using the orthogonal and rotatable central composite design (CCD). Under optimum conditions, the extraction recoveries ranging from 35.5 to 71.2 %, the relative standard deviations (RSD%) less than 6.45 %, and the detection limits in the range of 0.2-0.5 μg L-1 were achieved. The comparison of the extraction efficiency of the on-chip EME method using the electrospun PCL/MOF-199 nanofibers and PCL nanofibers membranes indicated that the proposed membrane was more efficient for extraction of sulfonamides because of the significant Lewis acid-base interactions of sulfonamides with copper uncoordinated open sites in MOF-199. Finally, the performance of the proposed method for extraction and determination of sulfonamides in three real samples was assayed.
Collapse
Affiliation(s)
- Elham Tahmasebi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731, Iran.
| | - Arezou Javadi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731, Iran
| |
Collapse
|
4
|
Martínez-Pérez-Cejuela H, Gionfriddo E. Evolution of Green Sample Preparation: Fostering a Sustainable Tomorrow in Analytical Sciences. Anal Chem 2024; 96:7840-7863. [PMID: 38687329 DOI: 10.1021/acs.analchem.4c01328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Affiliation(s)
- H Martínez-Pérez-Cejuela
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000, United States
| | - E Gionfriddo
- Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000, United States
| |
Collapse
|
5
|
Munjanja BK, Nomngongo PN, Mketo N. Mycotoxins in Vegetable Oils: A Review of Recent Developments, Current Challenges and Future Perspectives in Sample Preparation, Chromatographic Determination, and Analysis of Real Samples. Crit Rev Anal Chem 2023:1-14. [PMID: 38133964 DOI: 10.1080/10408347.2023.2286642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
Mycotoxins are toxic compounds that are formed as secondary metabolites by some fungal species that contaminate crops during pre- and postharvest stages. Exposure to mycotoxins can lead to adverse health effects in humans, such as carcinogenicity, mutagenicity, and teratogenicity. Hence, there is a need to develop analytical methods for their determination in vegetable oils that possess high sensitivity and selectivity. In the current review (116 references), the recent developments, current challenges, and perspectives in sample preparation techniques and chromatographic determination are summarized. It is impressive that current sample preparation techniques such as dispersive liquid-liquid microextraction (DLLME), quick, easy, cheap, rugged, and safe method (QuEChERS) and solid phase extraction (SPE) have exhibited high extraction recoveries and minimal matrix effects. However, a few studies have reported signal suppression or enhancement. Regarding chromatographic techniques, high sensitivity and selectivity have been reported by liquid chromatography coupled to fluorescence detection, tandem mass spectrometry, or high-resolution mass spectrometry. Furthermore, current challenges and perspectives in this field are tentatively proposed.
Collapse
Affiliation(s)
- Basil K Munjanja
- Department of Chemistry, University of South Africa, Roodepoort, South Africa
| | - Philiswa N Nomngongo
- Department of Chemical Sciences, University of Johannesburg, Johannesburg, South Africa
| | - Nomvano Mketo
- Department of Chemistry, University of South Africa, Roodepoort, South Africa
| |
Collapse
|
6
|
Mansour FR, Abdallah IA, Bedair A, Hamed M. Analytical Methods for the Determination of Quercetin and Quercetin Glycosides in Pharmaceuticals and Biological Samples. Crit Rev Anal Chem 2023; 55:187-212. [PMID: 37898879 DOI: 10.1080/10408347.2023.2269421] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
Flavonoids are plant-derived compounds that have several health benefits, including antioxidative, anti-inflammatory, anti-mutagenic, and anti-carcinogenic effects. Quercetin is a flavonoid that is widely present in various fruits, vegetables, and drinks. Accurate determination of quercetin in different samples is of great importance for its potential health benefits. This review, is an overview of sample preparation and determination methods for quercetin in diverse matrices. Previous research on sample preparation and determination methods for quercetin are summarized, highlighting the advantages and disadvantages of each method and providing insights into recent developments in quercetin sample treatment. Various analytical techniques are discussed including spectroscopic, chromatographic, electrophoretic, and electrochemical methods for the determination of quercetin and its derivatives in different samples. UV-Vis (Ultraviolet-visible) spectrophotometry is simple and inexpensive but lacks selectivity. Chromatographic techniques (HPLC, GC) offer selectivity and sensitivity, while electrophoretic and electrochemical methods provide high resolution and low detection limits, respectively. The aim of this review is to comprehensively explore the determination methods for quercetin and quercetin glycosides in diverse matrices, with emphasis on pharmaceutical and biological samples. The review also provides a theoretical basis for method development and application for the analysis of quercetin and quercetin glycosides in real samples.
Collapse
Affiliation(s)
- Fotouh R Mansour
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Tanta University, Tanta 31111, Egypt
| | - Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City 32897, Monufia, Egypt
| | - Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City 32897, Monufia, Egypt
| | - Mahmoud Hamed
- School of Information Technology and Computer Science (ITCS), Nile University, Giza, Egypt
| |
Collapse
|
7
|
Ryšavá L, Dorazilová J, Dvořák M, Sedláček P, Vojtová L, Kubáň P. Fully soluble polymeric foams for in-vial dried blood spot collection and analysis of acidic drugs by capillary electrophoresis. Anal Chim Acta 2023; 1241:340793. [PMID: 36657868 DOI: 10.1016/j.aca.2023.340793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/16/2022] [Accepted: 01/02/2023] [Indexed: 01/05/2023]
Abstract
Polymeric foams tailor-made of polyvinylpyrrolidone (PVP) and carboxymethylcellulose/oxidized 6-carboxycellulose (CMC07/OC) composite were proposed as suitable sorbents for the collection and analysis of dried blood spots (DBSs). The PVP and CMC07/OC foams were easy to prepare, enabled collection of minute volumes of capillary blood, and blood drying at ambient temperature. The resulting foams were prepared as small porous discs with uniform dimensions (approx. 6 × 3 mm) and were fully soluble in aqueous solutions. The DBSs were formed in standard capillary electrophoresis (CE) vials fitted with the soluble foam discs and enabled the direct in-vial DBS processing and at-line analysis by CE. The DBSs were pretreated with a simple process, which involved a complete dissolution of the foam disc in an acidic solution and a simultaneous hollow fiber liquid-phase microextraction (HF-LPME) in one step. The complete solubility of the foam disc with the DBS served for a quantitative transfer of all blood components into the eluate and a nearly exhaustive HF-LPME of target analytes, whereas the blood matrix and the polymeric foam components were efficiently retained by the organic solvent impregnated in the walls of the HF. The suitability of the PVP and CMC07/OC foams for the collection and the direct analysis of DBSs was demonstrated by the HF-LPME/CE determination of model acidic drugs (warfarin, ibuprofen, naproxen, ketoprofen, and diclofenac) at therapeutically relevant concentrations. Repeatability of the analytical method was better than 8.1% (RSD), extraction recoveries ranged from 70 to 99% (for PVP foam), calibration curves were linear over two orders of magnitude (R2 higher than 0.9991), and limits of detection were less than 44 μg/L (for concentrations in undiluted capillary blood). The soluble polymeric foams exhibited non-significant variations in analyte concentrations for DBSs prepared from blood samples with different hematocrit levels and for aged DBSs (less than 9.2%), moreover, they outperformed standard DBS sampling devices in terms of sample pretreatment time and extraction recovery.
Collapse
Affiliation(s)
- Lenka Ryšavá
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic; Institute of Food Science and Biotechnology, Faculty of Chemistry, Brno University of Technology, Purkyňova 118, CZ-61200, Brno, Czech Republic
| | - Jana Dorazilová
- Central European Institute of Technology, Advanced Biomaterials, Brno University of Technology, Purkyňova 656/123, CZ-612 00, Brno, Czech Republic
| | - Miloš Dvořák
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
| | - Petr Sedláček
- Institute of Physical and Applied Chemistry, Faculty of Chemistry, Brno University of Technology, Purkyňova 118, CZ-61200, Brno, Czech Republic
| | - Lucy Vojtová
- Central European Institute of Technology, Advanced Biomaterials, Brno University of Technology, Purkyňova 656/123, CZ-612 00, Brno, Czech Republic
| | - Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic.
| |
Collapse
|
8
|
de Paula Meirelles G, Fabris AL, Ferreira Dos Santos K, Costa JL, Yonamine M. Green Analytical Toxicology for the Determination of Cocaine Metabolites. J Anal Toxicol 2023; 46:965-978. [PMID: 35022727 DOI: 10.1093/jat/bkac005] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 12/30/2021] [Accepted: 01/11/2022] [Indexed: 01/26/2023] Open
Abstract
Brazil is the third largest contributor to Green Analytical Chemistry, and there is significant participation of toxicologists in the development and improvement of environmental techniques. Currently, toxicologists have their own strategies and guidelines to promote the reduction/replacement or elimination of solvents, reduce the impacts of derivatization and save time, among other objectives, due to the peculiarities of toxicological analysis. Thus, this review aims to propose the concept of Green Analytical Toxicology and conduct a discussion about its relevance and applications specifically in forensic toxicology, using the microextraction methods developed for the determination of cocaine and its metabolites as examples.
Collapse
Affiliation(s)
- Gabriela de Paula Meirelles
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of Sao Paulo (USP), Av. Professor Lineu Prestes, 580, 13B, Sao Paulo, SP 05508-000, Brazil
| | - André Luis Fabris
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of Sao Paulo (USP), Av. Professor Lineu Prestes, 580, 13B, Sao Paulo, SP 05508-000, Brazil
| | - Karina Ferreira Dos Santos
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of Sao Paulo (USP), Av. Professor Lineu Prestes, 580, 13B, Sao Paulo, SP 05508-000, Brazil
| | - José Luiz Costa
- Campinas Poison Control Center, University of Campinas (UNICAMP), R. Tessália Vieira de Camargo, 126, Campinas, SP 13083-859, Brazil.,Faculty of Pharmaceutical Sciences, University of Campinas (UNICAMP), R. Cândido Portinari, 200, Campinas, SP 13083-871, Brazil
| | - Mauricio Yonamine
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of Sao Paulo (USP), Av. Professor Lineu Prestes, 580, 13B, Sao Paulo, SP 05508-000, Brazil
| |
Collapse
|
9
|
Zedan HE, Mortada WI, Khalifa ME. Microextraction procedures for preconcentration of Fe (III) in water and food samples prior to colorimetric detection: a comparative study. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2022. [DOI: 10.1007/s13738-022-02697-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
AbstractTwo extraction procedures, namely dispersive liquid-liquid microextraction (DLLME) and dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFOD), have been compared for the spectrophotometric determination of Fe (III). In both procedures, Fe (III) was extracted after complexation with gallic acid in the presence of cetyltrimethylammonium bromide (CTAB). Tetrachloroethylene and 1-undecanol were used as extraction solvents in DLLME and DLLME-SFOD, respectively, while acetone was used as dispersing solvents. The effects of various experimental parameters (solution pH, the concentration of ligand and CTAB, as well as nature and amount of extraction and disperser solvents) on the extraction efficiency were investigated. Under optimum conditions, the calibration graphs were linear in the range of 50.0–650.0 and 8.0–800.0 μg L−1 and the detection limits were 15.0 and 5.0 μg L−1 for DLLME and DLLME-SFOD, respectively. The presence of NaCl, up to 1.0% (w/v) did not impact the extraction procedures. The analyte was good tolerated in the presence of most concomitant ions. The procedures were applied for the determination of Fe (III) in standard reference materials and real samples with good recoveries (95.5–99.0%) for DLLME-SFOD while poor recoveries (68.0–82.5%) were obtained when DLLME was applied. The analytical figures of the procedures were comparable with those listed in the literature and it could be concluded that DLLME-SFOD may be considered one of the best tools used for preconcentration of Fe (III), owing to its simplicity, time-saving and the possibility of using in conventional analytical laboratories.
Graphical abstract
Collapse
|
10
|
Olasupo A, Suah FBM. Trends in hollow fibre liquid phase microextraction for the preconcentration of pharmaceutically active compounds in aqueous solution: A case for polymer inclusion membrane. JOURNAL OF HAZARDOUS MATERIALS 2022; 431:128573. [PMID: 35278960 DOI: 10.1016/j.jhazmat.2022.128573] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 02/06/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Low concentrations of pharmaceutically active compounds have been reported in samples from highly complex aqueous environments. Due to their low concentrations, efficient sample pretreatment methods are needed to clean samples and concentrate the compounds of interest prior to instrumental analysis. Hollow fibre liquid-phase microextraction (HF-LPME) is an effective alternative to conventional techniques such as liquid-liquid extraction (LLE) and solid phase extraction (SPE) because it consumes less organic solvent and is less labour intensive with a short extraction time. HF-LPME involves the preconcentration and mass transfer of target analytes from an aqueous sample into an acceptor solution in the lumen of the fibre using a supported liquid membrane (SLM) impregnated in the hollow fibre pores. However, despite the high contaminant selectivity, reproducibility, and enrichment that HF-LPME offers, this technique is limited by membrane instability. Although several advances have been made to address membrane instability, they are either too costly or not feasible for industrial application. Hence, hollow fibre polymer inclusion membrane liquid-phase microextraction (HF-PIM-LPME) was introduced to ameliorate membrane instability. This new approach uses ionic liquids (ILs) as a green solvent, and has demonstrated high membrane stability, good contaminant enrichment, and similar selectivity and reproducibility to HF-SLM-LPME. Hence, this review aims to raise awareness of HF-PIM-LPME as a viable alternative for the selectivity and preconcentration of pharmaceuticals and other contaminants in aquatic environments.
Collapse
Affiliation(s)
- Ayo Olasupo
- Green Analytical Chemistry Laboratory, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Minden, Pulau Pinang, Malaysia
| | - Faiz Bukhari Mohd Suah
- Green Analytical Chemistry Laboratory, School of Chemical Sciences, Universiti Sains Malaysia, 11800 Minden, Pulau Pinang, Malaysia.
| |
Collapse
|
11
|
Alexandridou A, Volmer DA. Sample preparation techniques for extraction of vitamin D metabolites from non-conventional biological sample matrices prior to LC-MS/MS analysis. Anal Bioanal Chem 2022; 414:4613-4632. [PMID: 35501505 PMCID: PMC9174318 DOI: 10.1007/s00216-022-04097-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 04/13/2022] [Accepted: 04/22/2022] [Indexed: 12/18/2022]
Abstract
The determination of vitamin D metabolites as status marker or for diagnostic purposes is almost entirely conducted from blood serum or plasma. Other biological matrices, however, have also interested researchers, for two main reasons: (1) alternative matrices may allow non-invasive sampling, permit easier sample transfer and require less demanding storage conditions; and (2) the levels of vitamin D metabolites in other body compartments may further aid the understanding of vitamin D metabolism and function. Thus, the development of reliable and efficient sample preparation protocols for sample matrices other than serum/plasma, which will remove potential interferences and selectively extract the targeted metabolites, is of great importance. This review summarizes sample preparation methods for measurement of vitamin D metabolites using liquid chromatography-(tandem)mass spectrometry in more than ten different human tissues, including hair, saliva, adipose tissue, brain and others.
Collapse
Affiliation(s)
- Anastasia Alexandridou
- Bioanalytical Chemistry, Humboldt University Berlin, Brook-Taylor-Str. 2, 12489, Berlin, Germany
| | - Dietrich A Volmer
- Bioanalytical Chemistry, Humboldt University Berlin, Brook-Taylor-Str. 2, 12489, Berlin, Germany.
| |
Collapse
|
12
|
Membrane-based liquid-phase microextraction of basic pharmaceuticals - A study on the optimal extraction window. J Chromatogr A 2021; 1664:462769. [PMID: 34998024 DOI: 10.1016/j.chroma.2021.462769] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 12/10/2021] [Accepted: 12/20/2021] [Indexed: 11/23/2022]
Abstract
The present paper defines the optimal extraction window (OEW) for three-phase membrane-based liquid-phase microextraction (MP-LPME) in terms of analyte polarity (log P), and anchors this to existing theories for equilibrium partitioning and kinetics. Using deep eutectic solvents (DES) as supported liquid membranes (SLM), we investigated how the OEW was affected by ionic-, hydrogen bond and π-π interactions between the SLM and analyte. Eleven basic model analytes in the range -0.4 < log P < 5.0 were extracted by MB-LPME in a 96-well format. Extraction was performed from 250 µL standard solution in 25 mM phosphate buffer (pH 7.0) into 50 µL of 10 mM HCl acceptor solution (pH 2.0) with mixtures of coumarin, camphor, DL-menthol, and thymol, with and without the ionic carrier di(2-ethylhexyl) phosphate (DEHP), as the SLM. The OEW with pure DES was in the range 2 < log P < 5, and low SLM aromaticity was favorable for the extraction of non-polar analytes. Here, extraction recoveries up to 98% were obtained. Upon addition of DEHP to the SLMs, the OEW shifted to the range -0.5 < log P < 2, and a combination of 5% DEHP and moderate aromaticity resulted in extraction recoveries up to 80% for the polar analytes. Extraction with ionic carrier was inefficient for the non-polar analytes, due to excessive trapping in the SLM. The results from our study show that LPME performs optimally in a relatively narrow log P-window of ≈ 2-3 units and that the OEW is primarily affected by ionic carrier and aromaticity.
Collapse
|
13
|
|
14
|
Sensitive determination of illicit drugs in wastewater using enrichment bag-based liquid-phase microextraction and liquid-chromatography tandem mass spectrometry. J Chromatogr A 2021; 1661:462684. [PMID: 34875518 DOI: 10.1016/j.chroma.2021.462684] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/09/2021] [Accepted: 11/11/2021] [Indexed: 10/19/2022]
Abstract
To concentrate trace level of analytes in complex wastewater, sample preparation is necessary prior to instrumental analysis. In this work, an enrichment bag-based liquid-phase microextraction (EB-LPME) system was therefore proposed for the first time to isolate and enrich the illicit drugs (amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, codeine and fentanyl) from wastewater. Under the optimum EB-LPME conditions, the recoveries of the model illicit drugs were 40-93% with enrichment factors up to 93. The optimized EB-LPME was compared to hollow fiber-LPME (HF-LPME) in terms of the thickness of the supported liquid membrane (SLM), the effective SLM area, extraction recovery and mass transfer flux. Compared with HF-LPME, EB-LPME possesses larger effective SLM area, and provided higher extraction recovery. In addition, EB-LPME provided larger mass transfer flux than HF-LPME, which was mainly due to the differences in SLM thickness. Therefore, SLM thickness was identified as the main mass transfer flux-determining factor experimentally. The matrix effect of EB-LPME was evaluated using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and excellent sample clean-up was confirmed. Subsequently, EB-LPME-LC-MS/MS was validated with satisfactory results, and the detection of limit of the proposed method was in the range of 0.3-8.7 ng/L. Finally, with standard addition method, EB-LPME-LC-MS/MS was successfully applied for the determination of the model drugs in a local hospital wastewater from Wuhan, China. This study clearly showed that EB-LPME displayed great potential as an efficient sample preparation method for isolation and enrichment of the drugs/pollutants from complex environmental samples for wastewater-based epidemiology in the near future.
Collapse
|
15
|
Öner M, Bodur S, Erarpat S, Bakirdere S. A Novel Hydrogen Fluoride Assisted-Glass Surface Etching Based Liquid Phase Microextraction for the Determination of 4-n-Nonylphenol in Water by Gas Chromatography-Mass Spectrometry with Matrix Matching Strategy. ANAL SCI 2021; 37:1433-1438. [PMID: 33867401 DOI: 10.2116/analsci.21p013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A novel extraction method named hydrogen fluoride assisted-glass surface etching based liquid phase microextraction (HF-GSE-LPME) was proposed to determine 4-n-nonylphenol at trace levels by gas chromatography-mass spectrometry (GC-MS). After the evaluation of system analytical performance for the HF-GSE-LPME-GC-MS system, limit of detection (LOD) and limit of quantification (LOQ) values were calculated as 7.1 and 23.8 ng/g, respectively. Enhancement in detection power of the method was determined to be 22 fold when LOD values of the GC-MS and HF-GSE-LPME-GC-MS systems were compared with each other. Applicability and accuracy of the established method were checked by performing spiking experiments. A matrix matching calibration strategy was applied to boost the accuracy of quantification in both matrices, and the percent recovery results obtained for bottled drinking water and dam lake water samples were in the range of 98 - 107 and 90 - 117%, respectively.
Collapse
Affiliation(s)
- Miray Öner
- Department of Chemistry, Faculty of Art and Science, Yildiz Technical University
| | - Süleyman Bodur
- Department of Chemistry, Faculty of Art and Science, Yildiz Technical University
| | - Sezin Erarpat
- Department of Chemistry, Faculty of Art and Science, Yildiz Technical University
| | - Sezgin Bakirdere
- Department of Chemistry, Faculty of Art and Science, Yildiz Technical University.,Turkish Academy of Sciences (TÜBA)
| |
Collapse
|
16
|
Alidoust M, Baharfar M, Manouchehri M, Yamini Y, Tajik M, Seidi S. Emergence of microfluidic devices in sample extraction; an overview of diverse methodologies, principals, and recent advancements. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116352] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
17
|
Dmitrienko SG, Apyari VV, Tolmacheva VV, Gorbunova MV. Liquid–Liquid Extraction of Organic Compounds into a Single Drop of the Extractant: Overview of Reviews. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821080049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
18
|
Kraševec I, Prosen H. Determination of polar benzotriazoles in aqueous environmental samples by hollow-fibre microextraction method with LC-MS/MS and its comparison to a conventional solid-phase extraction method. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106191] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
19
|
Ferrofluids-based microextraction systems to process organic and inorganic targets: The state-of-the-art advances and applications. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116232] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
20
|
Ahmad SM, Gonçalves OC, Oliveira MN, Neng NR, Nogueira JMF. Application of Microextraction-Based Techniques for Screening-Controlled Drugs in Forensic Context-A Review. Molecules 2021; 26:2168. [PMID: 33918766 PMCID: PMC8070059 DOI: 10.3390/molecules26082168] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/03/2021] [Accepted: 04/06/2021] [Indexed: 01/12/2023] Open
Abstract
The analysis of controlled drugs in forensic matrices, i.e., urine, blood, plasma, saliva, and hair, is one of the current hot topics in the clinical and toxicological context. The use of microextraction-based approaches has gained considerable notoriety, mainly due to the great simplicity, cost-benefit, and environmental sustainability. For this reason, the application of these innovative techniques has become more relevant than ever in programs for monitoring priority substances such as the main illicit drugs, e.g., opioids, stimulants, cannabinoids, hallucinogens, dissociative drugs, and related compounds. The present contribution aims to make a comprehensive review on the state-of-the art advantages and future trends on the application of microextraction-based techniques for screening-controlled drugs in the forensic context.
Collapse
Affiliation(s)
- Samir M. Ahmad
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Molecular Pathology and Forensic Biochemistry Laboratory, CiiEM, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
- Forensic and Psychological Sciences Laboratory Egas Moniz, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
| | - Oriana C. Gonçalves
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Mariana N. Oliveira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Nuno R. Neng
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| | - José M. F. Nogueira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| |
Collapse
|
21
|
Hollow fiber liquid-phase microextraction combined with supercritical fluid chromatography coupled to mass spectrometry for multiclass emerging contaminant quantification in water samples. Anal Bioanal Chem 2021; 413:2467-2479. [PMID: 33532915 DOI: 10.1007/s00216-021-03202-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 01/21/2021] [Accepted: 01/26/2021] [Indexed: 12/22/2022]
Abstract
The hollow fiber liquid-phase microextraction allows highly selective concentration of organic compounds that are at trace levels. The determination of those analytes through the supercritical fluid chromatography usage is associated with many analytical benefits, which are significantly increased when it is coupled to a mass spectrometry detector, thus providing an extremely sensitive analytical technique with minimal consumption of organic solvents. On account of this, a hollow fiber liquid-phase microextraction technique in two-phase mode combined with supercritical fluid chromatography coupled to mass spectrometry was developed for quantifying 19 multiclass emerging contaminants in water samples in a total chromatographic time of 5.5 min. The analytical method used 40 μL of 1-octanol placed in the porous-walled polypropylene fiber as the acceptor phase, and 1 L of water sample was the donor phase. After extraction and quantification techniques were optimized in detail, a good determination coefficient (r2 > 0.9905) in the range of 0.1 to 100 μg L-1, for most of the analytes, and an enrichment factor in the range of 7 to 28,985 were obtained. The recovery percentage (%R) and intraday precision (%RSD) were in the range of 80.80-123.40%, and from 0.48 to 16.89%, respectively. Limit of detection and quantification ranged from 1.90 to 35.66 ng L-1, and from 3.41 to 62.11 ng L-1, respectively. Finally, the developed method was successfully used for the determination of the 19 multiclass emerging contaminants in superficial and wastewater samples.
Collapse
|
22
|
Plastiras OE, Andreasidou E, Samanidou V. Microextraction Techniques with Deep Eutectic Solvents. Molecules 2020; 25:E6026. [PMID: 33352701 PMCID: PMC7767243 DOI: 10.3390/molecules25246026] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/14/2020] [Accepted: 12/18/2020] [Indexed: 01/20/2023] Open
Abstract
In this review, the ever-increasing use of deep eutectic solvents (DES) in microextraction techniques will be discussed, focusing on the reasons needed to replace conventional extraction techniques with greener approaches that follow the principles of green analytical chemistry. The properties of DES will be discussed, pinpointing their exceptional performance and analytical parameters, justifying their current extensive scientific interest. Finally, a variety of applications for commonly used microextraction techniques will be reported.
Collapse
Affiliation(s)
| | | | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 541 24 Thessaloniki, Greece; (O.-E.P.); (E.A.)
| |
Collapse
|
23
|
Application of microextraction techniques in alternative biological matrices with focus on forensic toxicology: a review. Bioanalysis 2020; 13:45-64. [PMID: 33326299 DOI: 10.4155/bio-2020-0241] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
The interest in alternative biological matrices (e.g., hair and saliva) for forensic toxicology analysis has increased, and recent developments in sample preparation have targeted rapid, cheap, efficient and eco-friendly methods, including microextraction techniques. For this review, we have gathered information about these two hot topics. We discuss the composition, incorporation of analytes and advantages and disadvantages of different biological matrices, and also present the operation principles of the most reported microextraction procedures and their application in forensic toxicology. The outcome of this review may encourage future forensic researches into alternative samples and microextraction techniques.
Collapse
|
24
|
Peng LQ, Cao J. Modern microextraction techniques for natural products. Electrophoresis 2020; 42:219-232. [PMID: 33215711 DOI: 10.1002/elps.202000248] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/16/2020] [Accepted: 11/03/2020] [Indexed: 11/11/2022]
Abstract
Natural product analysis has gained wide attention in recent years, especially for herbal medicines, which contain complex ingredients and play a significant clinical role in the therapy of numerous diseases. The constituents of natural products are usually found at low concentrations, and the matrices are complex. Thus, the extraction of target compounds from natural products before analysis by analytical instruments is very significant for human health and its wide application. The commonly used traditional extraction methods are time-consuming, using large amounts of sample and organic solvents, as well as expensive and inefficient. Recently, microextraction techniques have been used for natural product extraction to overcome the disadvantages of conventional extraction methods. In this paper, the successful applications of and recent developments in microextraction techniques including solvent-based and sorbent-based microextraction methods, in natural product analysis in recent years, especially in the last 5 years, are reviewed for the first time. Their features, advantages, disadvantages, and future development trends are also discussed.
Collapse
Affiliation(s)
- Li-Qing Peng
- College of Pharmaceutical Sciences, Hangzhou Normal University, Hangzhou, 311121, P. R. China
| | - Jun Cao
- College of Pharmaceutical Sciences, Hangzhou Normal University, Hangzhou, 311121, P. R. China.,College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 311121, P. R. China
| |
Collapse
|
25
|
Silveira GDO, Lourenço FR, Bruno V, Yonamine M. Fast Hollow Fiber Liquid-Phase Microextraction as a Greener Alternative for the Determination of N,N-Dimethyltryptamine and Harmala Alkaloids in Human Urine. Front Chem 2020; 8:558501. [PMID: 33134270 PMCID: PMC7575737 DOI: 10.3389/fchem.2020.558501] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Accepted: 09/08/2020] [Indexed: 01/16/2023] Open
Abstract
Ayahuasca tea is an entheogen hallucinogenic beverage used for shamanic and spiritual purposes, prepared by the decoction of different Amazonian plants containing N,N-dimethyltryptamine (DMT) and harmala alkaloids. Since the therapeutic potential of this tea has been broadly studied in recent years, mainly for the treatment of psychiatric disorders, the determination of the ayahuasca tea components in human and animal matrices is of utmost importance. In order to avoid the use of large amounts of toxic solvents, typically employed in traditional sample preparation methods, hollow fiber liquid-phase microextraction (HF-LPME) presents a greener and time-saving alternative. The present study aims to fully develop and apply an HF-LPME method for the determination of DMT, harmine (HRM), harmaline (HRL), and tetrahydroharmine (THH) in human urine samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Fractional factorial and Box–Behnken designs were used to identify and optimize significant method variables. Once optimized, validation has shown a limit of detection (LoD) of 1.0 ng/ml for DMT and 2.0 ng/ml for the harmala alkaloid. The limit of quantification (LoQ) was of 5.0 ng/ml for all analytes. The method has shown to be linear over a concentration range of 5–200 ng/ml (r2 ≥ 0.99). Intra/inter-day precision and accuracy met the acceptance criteria at the three quality control (QC) levels studied (15.0, 90.0, and 170.0 ng/ml, n = 6, each). Matrix effect evaluation showed predominant ion enhancement and recovery values were above 80%. Dilution factors of 10- and 20-fold have shown acceptable values of accuracy. Selectivity studies showed no interferences. Analysis of eight authentic samples collected from four subjects proved method feasibility. A simple, time-saving and green alternative for the analysis of DMT and harmala alkaloids in human urine samples was developed, optimized using design of experiments, fully validated and applied to authentic samples.
Collapse
Affiliation(s)
- Gabriela de Oliveira Silveira
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Felipe Rebello Lourenço
- Department of Pharmacy, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Vitor Bruno
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Mauricio Yonamine
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
26
|
Application of Hollow Fibre-Liquid Phase Microextraction Technique for Isolation and Pre-Concentration of Pharmaceuticals in Water. MEMBRANES 2020; 10:membranes10110311. [PMID: 33137884 PMCID: PMC7693864 DOI: 10.3390/membranes10110311] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/14/2020] [Accepted: 09/17/2020] [Indexed: 12/12/2022]
Abstract
In this article, a comprehensive review of applications of the hollow fibre-liquid phase microextraction (HF-LPME) for the isolation and pre-concentration of pharmaceuticals in water samples is presented. HF-LPME is simple, affordable, selective, and sensitive with high enrichment factors of up to 27,000-fold reported for pharmaceutical analysis. Both configurations (two- and three-phase extraction systems) of HF-LPME have been applied in the extraction of pharmaceuticals from water, with the three-phase system being more prominent. When compared to most common sample preparation techniques such as solid phase extraction, HF-LPME is a greener analytical chemistry process due to reduced solvent consumption, miniaturization, and the ability to automate. However, the automation comes at an added cost related to instrumental set-up, but a reduced cost is associated with lower reagent consumption as well as shortened overall workload and time. Currently, many researchers are investigating ionic liquids and deep eutectic solvents as environmentally friendly chemicals that could lead to full classification of HF-LPME as a green analytical procedure.
Collapse
|
27
|
Dominguez-Tello A, Dominguez-Alfaro A, Gómez-Ariza JL, Arias-Borrego A, García-Barrera T. Effervescence-assisted spiral hollow-fibre liquid-phase microextraction of trihalomethanes, halonitromethanes, haloacetonitriles, and haloketones in drinking water. JOURNAL OF HAZARDOUS MATERIALS 2020; 397:122790. [PMID: 32388100 DOI: 10.1016/j.jhazmat.2020.122790] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 04/18/2020] [Accepted: 04/18/2020] [Indexed: 06/11/2023]
Abstract
A new analytical method was optimized to determine 18 disinfection by-products (DBPs) in drinking water, including four different chemical groups. For this purpose, spiral-shaped hollow-fibre liquid phase microextraction with 1-octanol as the acceptor solvent assisted by effervescence was applied using a homemade supporting device that was specifically designed for this application. The device was printed in a 3D printer and allows for an increased fibre surface even with a low sample volume, which significantly facilitates the extraction. The samples were analysed by gas chromatography coupled to both an electron capture detector and a mass spectrometer for the quantification and unequivocal identification of the analytes, respectively. Effervescence was generated using citric acid and bicarbonate at a molar ratio 1:2, which significantly improves the extraction efficiency and reduces mechanical operations, since stirring and modifiers are not required. The results showed enrichment factors ranging from 13.1 to 140.1. Satisfactory recoveries (80-113 %) were obtained, with relative standard deviations from 3 to 15 % and good linearity. The detection limits (ng L-1) ranged from 10 to 35 (trihalomethanes), 12 to 220 (halonitromethanes), 17 to 79 (haloacetonitriles) and 10 to 16 (haloketones). The applicability of the method was assessed in 6 local water distribution systems.
Collapse
Affiliation(s)
- A Dominguez-Tello
- GIAHSA - Water Management Public Company of Huelva. Carretera A-492 Km.4, 21110 Aljaraque, Huelva, Spain
| | - A Dominguez-Alfaro
- Department of Chemistry, Faculty of Experimental Sciences, University of Huelva, Campus de El Carmen, Av. Fuerzas Armadas, 21007, Huelva, Spain
| | - J L Gómez-Ariza
- Department of Chemistry, Faculty of Experimental Sciences, University of Huelva, Campus de El Carmen, Av. Fuerzas Armadas, 21007, Huelva, Spain; ceiA3 - Agrifood Campus of International Excellence, University of Huelva, Spain; Research Centre for Natural Resources, Health and the Environment (RENSMA), University of Huelva, Av. Fuerzas Armadas, 21007, Huelva, Spain
| | - A Arias-Borrego
- Department of Chemistry, Faculty of Experimental Sciences, University of Huelva, Campus de El Carmen, Av. Fuerzas Armadas, 21007, Huelva, Spain; ceiA3 - Agrifood Campus of International Excellence, University of Huelva, Spain; Research Centre for Natural Resources, Health and the Environment (RENSMA), University of Huelva, Av. Fuerzas Armadas, 21007, Huelva, Spain.
| | - T García-Barrera
- Department of Chemistry, Faculty of Experimental Sciences, University of Huelva, Campus de El Carmen, Av. Fuerzas Armadas, 21007, Huelva, Spain; ceiA3 - Agrifood Campus of International Excellence, University of Huelva, Spain; Research Centre for Natural Resources, Health and the Environment (RENSMA), University of Huelva, Av. Fuerzas Armadas, 21007, Huelva, Spain.
| |
Collapse
|
28
|
Dmitrienko SG, Apyari VV, Tolmacheva VV, Gorbunova MV. Dispersive Liquid–Liquid Microextraction of Organic Compounds: An Overview of Reviews. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s1061934820100056] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
29
|
Naing NN, Lee HK. Microextraction and analysis of contaminants adsorbed on atmospheric fine particulate matter: A review. J Chromatogr A 2020; 1627:461433. [DOI: 10.1016/j.chroma.2020.461433] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 07/22/2020] [Accepted: 07/24/2020] [Indexed: 11/26/2022]
|
30
|
Majumder S, Marguí E, Roman-Ross G, Chatterjee D, Hidalgo M. Hollow fiber liquid phase microextraction combined with total reflection X-ray fluorescence spectrometry for the determination of trace level inorganic arsenic species in waters. Talanta 2020; 217:121005. [PMID: 32498873 DOI: 10.1016/j.talanta.2020.121005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 03/30/2020] [Accepted: 04/03/2020] [Indexed: 11/15/2022]
Abstract
In the present study, we investigated the possibilities and drawbacks of hollow fiber liquid phase microextraction (HF-LPME) combined with total reflection X-ray fluorescence (TXRF) spectrometry for the determination of low amounts of inorganic arsenic (As) species in water samples. The obtained results showed that a three-phase HF-LPME system was more suitable to be used in combination with TXRF than the two phase configuration, since lower detection limit and better precision for As determination can be attained. Relevant experimental parameters affecting As extraction (i.e. types of extractant, organic solvent, agitation speed, pH and extraction time) and TXRF analysis (deposition volume and drying mode) were systematically evaluated. It was found that As(III) was more efficiently extracted at pH 13, whereas, optimum pH for As(V) extraction was at pH 8.5. Limits of detection (LOD) achieved using the best analytical conditions meet the requirements of current legislation and allow the determination of inorganic As(V) and As(III) in water. The proposed method was also applied to different spiked environmental water samples for the preconcentration and subsequent determination of trace inorganic As species.
Collapse
Affiliation(s)
- Santanu Majumder
- Department of Chemistry, University of Girona, Campus Montilivi, s/n. 17071, Girona, Spain; Department of Geology & Geophysics, Texas A&M University, College Station, TX, 77843-3115, USA; Departmental of Environmental Management, International Centre for Ecological Engineering, University of Kalyani, Kalyani, 741 235, West Bengal, India; Department of Chemistry, University of Kalyani, Kalyani, 741 235, West Bengal, India
| | - Eva Marguí
- Department of Chemistry, University of Girona, Campus Montilivi, s/n. 17071, Girona, Spain
| | - Gabriela Roman-Ross
- AMPHOS 21 Consulting S.L., Passeig de Garcia i Faria 49-51, 08034, Barcelona, Spain
| | - Debashis Chatterjee
- Department of Chemistry, University of Kalyani, Kalyani, 741 235, West Bengal, India
| | - Manuela Hidalgo
- Department of Chemistry, University of Girona, Campus Montilivi, s/n. 17071, Girona, Spain.
| |
Collapse
|
31
|
Khatibi SA, Hamidi S, Siahi-Shadbad MR. Application of Liquid-Liquid Extraction for the Determination of Antibiotics in the Foodstuff: Recent Trends and Developments. Crit Rev Anal Chem 2020; 52:327-342. [DOI: 10.1080/10408347.2020.1798211] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Seyed Amin Khatibi
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
| | - Samin Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
| | - Mohammad Reza Siahi-Shadbad
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
- Department of Pharmaceutical and Food Control, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
32
|
Optimization of hollow-fiber liquid phase microextraction for polychlorinated biphenyls in human breast milk. J Chromatogr A 2020; 1626:461381. [DOI: 10.1016/j.chroma.2020.461381] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 05/29/2020] [Accepted: 06/29/2020] [Indexed: 02/07/2023]
|
33
|
Zhang SM, Zhang XX, Chen X, Hu S, Bai XH. Deep eutectic solvent-based hollow fiber liquid-phase microextraction for quantification of Q-markers of cinnamic acid derivatives in traditional Chinese medicines and research of their plasma protein binding rates. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104696] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
34
|
Hong R, Wu P, Lin J, Huang L, Yang L, Wu Y, Yao H. Three-phase hollow fiber liquid-phase microextraction combined with HPLC for determination of three trace acidic plant growth regulators in Anoectochilus roxburghii (Wall.) Lindl. J Sep Sci 2020; 43:2773-2783. [PMID: 32306553 DOI: 10.1002/jssc.201901321] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 04/09/2020] [Accepted: 04/15/2020] [Indexed: 11/07/2022]
Abstract
The analysis of plant growth regulators presents a challenge due to their trace quantities and complex matrices. A novel, simple, and effective analytical method for the determination of three trace acidic plant growth regulators in Anoectochilus roxburghii (Wall.) Lindl was developed to address this issue. Three-phase hollow fiber liquid-phase microextraction combined with high-performance liquid chromatography was applied for the enrichment, purification, and determination of three acidic plant growth regulators, namely, indole-3-acetic-acid, indole-3-butyric-acid, and (+)-abscisic acid. The factors affecting extraction performance, including extractant species, pH of donor and acceptor phases, salt addition dosage, extraction time, temperature, and stirring rate, were investigated and optimized. Under optimum conditions, the proposed method provided good linearity (R2 , 0.9994-0.9999), low limit of detection (0.038-0.12 ng/mL), and acceptable relative recoveries (56.7-117.6%). The enrichment factors were between 153 and 328. The developed method was successfully applied to the enrichment and determination of plant growth regulators in Anoectochilus roxburghii (Wall.) Lindl and exhibited increased purification capacity, higher sensitivity, and decreased organic solvent consumption compared with conventional sample preparation methods. This method may provide a testing platform for the monitoring of plant growth regulator residues, ensuring the safe and effective use of traditional Chinese medicine.
Collapse
Affiliation(s)
- Ruixia Hong
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Pingping Wu
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Jin Lin
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Liying Huang
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Lijuan Yang
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Youjia Wu
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| | - Hong Yao
- School of Pharmacy, Fujian Medical University, Fuzhou, Fujian, 350122, P. R. China
| |
Collapse
|
35
|
Khan WA, Arain MB, Yamini Y, Shah N, Kazi TG, Pedersen-Bjergaard S, Tajik M. Hollow fiber-based liquid phase microextraction followed by analytical instrumental techniques for quantitative analysis of heavy metal ions and pharmaceuticals. J Pharm Anal 2020; 10:109-122. [PMID: 32373384 PMCID: PMC7192972 DOI: 10.1016/j.jpha.2019.12.003] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/09/2019] [Accepted: 12/11/2019] [Indexed: 02/07/2023] Open
Abstract
Hollow-fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) are miniaturized extraction techniques, and have been coupled with various analytical instruments for trace analysis of heavy metals, drugs and other organic compounds, in recent years. HF-LPME and EME provide high selectivity, efficient sample cleanup and enrichment, and reduce the consumption of organic solvents to a few micro-liters per sample. HF-LPME and EME are compatible with different analytical instruments for chromatography, electrophoresis, atomic spectroscopy, mass spectrometry, and electrochemical detection. HF-LPME and EME have gained significant popularity during the recent years. This review focuses on hollow fiber based techniques (especially HF-LPME and EME) of heavy metals and pharmaceuticals (published 2017 to May 2019), and their combinations with atomic spectroscopy, UV-VIS spectrophotometry, high performance liquid chromatography, gas chromatography, capillary electrophoresis, and voltammetry.
Collapse
Affiliation(s)
- Wajid Ali Khan
- Department of Chemistry, Abdul Wali Khan University Mardan, 23200, KPK, Pakistan
| | - Muhammad Balal Arain
- Department of Chemistry, Abdul Wali Khan University Mardan, 23200, KPK, Pakistan
- Department of Chemistry, University of Karachi, 75270, Karachi, Pakistan
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P. O. Box 14115-175, Tehran, Iran
| | - Nasrullah Shah
- Department of Chemistry, Abdul Wali Khan University Mardan, 23200, KPK, Pakistan
| | - Tasneem Gul Kazi
- National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Sindh, Pakistan
| | | | - Mohammad Tajik
- Department of Chemistry, Tarbiat Modares University, P. O. Box 14115-175, Tehran, Iran
| |
Collapse
|
36
|
Wang T, Xie T, Xu C. Numerical investigations of micro-SLM extraction/stripping in a spiral channel. Chem Eng Sci 2020. [DOI: 10.1016/j.ces.2019.115344] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
37
|
Badiee H, Zanjanchi MA, Zamani A, Fashi A. Hollow fiber liquid-phase microextraction based on the use of a rotating extraction cell: A green approach for trace determination of rhodamine 6G and methylene blue dyes. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 255:113287. [PMID: 31600705 DOI: 10.1016/j.envpol.2019.113287] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 09/08/2019] [Accepted: 09/19/2019] [Indexed: 06/10/2023]
Abstract
In this work, a novel mode of hollow fiber liquid-phase microextraction (HF-LPME) technique namely rotating extraction cell solvent bar microextraction (REC-SBME) was introduced. The proposed method was applied for the preconcentration of methylene blue (MB) and rhodamine 6G (RG) in some real samples, including soft drink, lipstick, environmental water, and wastewater samples. In the extraction setup, two pieces of hollow fibers were fixed on a mechanical support and immersed in a rotating extraction cell containing the sample solution during the extraction process. The rotation of the extraction cell by using an electric motor led to an enhancement in the mass transfer of the dyes from the sample solution into the organic acceptor phase. In the developed procedure, the UV-Vis spectrophotometry and HPLC-UV/Vis were employed as detection methods for the analysis of the acceptor phase and the obtained results were compared. Optimization of the extraction factors affecting the method, including organic solvent type, sample solution pH, extraction time, rotational rate, the volume of sample and acceptor solutions, salt addition, and temperature was performed in order to obtain the best preconcentration factor. Linear dynamic range obtained by HPLC-UV/Vis and spectrophotometry was observed in the ranges of 2.5-1200 ng mL-1 for RG and 1.6-600 ng mL-1 for MB with R2 more than 0.9971. Also, relative standard deviation (RSD) values (n = 3) less than 3.8% were obtained. The good conformity of the obtained results makes UV-Vis spectrophotometric method an ideal tool for routine analysis of trace dyes in the complex matrices after REC-SBME.
Collapse
Affiliation(s)
- Hamid Badiee
- Department of Chemistry, Faculty of Science, University of Guilan, University Campus 2, Rasht, Iran; Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Postal Code 45371-38791, Zanjan, Iran
| | - Mohammad Ali Zanjanchi
- Department of Chemistry, Faculty of Science, University of Guilan, University Campus 2, Rasht, Iran; Department of Chemistry, Faculty of Science, University of Guilan, Rasht, 41335-1914, Iran
| | - Abbasali Zamani
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Postal Code 45371-38791, Zanjan, Iran.
| | - Armin Fashi
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Postal Code 45371-38791, Zanjan, Iran
| |
Collapse
|
38
|
Mahmoudi A, Rajabi M. Selective determination of some beta-blockers in urine and plasma samples using continuous flow membrane microextraction coupled with high performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1128:121768. [PMID: 31491695 DOI: 10.1016/j.jchromb.2019.121768] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Revised: 08/15/2019] [Accepted: 08/16/2019] [Indexed: 11/30/2022]
Abstract
In this work, an efficient method termed as continuous flow membrane microextraction coupled with high performance liquid chromatography is introduced for a highly selective determination of metoprolol and propranolol in the biological samples. According to this method, an aqueous source phase of the analytes (donor phase, 10 mL) is circulated into an extraction cell, which is separated from an aqueous acceptor phase (100 μL) by a small piece of polypropylene membrane sheet whose pores are impregnated by an organic solvent (1-octanol, 15 μL). The analytes are extracted from the donor phase into the organic solvent. They are subsequently selectively back-extracted into the acceptor solution due to the pH gradient. The proposed method is very convenient and has the capability of being fully automated. It provides a good preconcentration and an excellent repeatability. The extractant is an aqueous phase, and by prevention of the extraction of macromolecules through the membrane, the developed method provides a high sample clean-up. In order to maximize the extraction efficiency, the influential parameters including the type of mediator solvent, pH values for the donor and acceptor solutions, extraction time, ionic strength, stirring rate, and volume of the acceptor solution are optimized. The calibration curves were obtained with a reasonable linearity (r2 = 0.999) in the range of 3-1000 ng mL-1. The limits of detection were 0.5 and 1.0 ng mL-1, and excellent relative standard deviations were obtained (between 3.2% and 4.0%). Finally, the reliability of the procedure is evaluated by determination of metoprolol and propranolol in the human urine and plasma samples, which indicates the suitability, sensitivity, and high sample clean-up of the proposed method.
Collapse
Affiliation(s)
- Atefeh Mahmoudi
- Department of Chemistry, Semnan University, Semnan 2333383-193, Iran
| | - Maryam Rajabi
- Department of Chemistry, Semnan University, Semnan 2333383-193, Iran.
| |
Collapse
|
39
|
Selecting an extraction solvent for a greener liquid phase microextraction (LPME) mode-based analytical method. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.05.012] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
40
|
Ryšavá L, Dvořák M, Kubáň P. The effect of membrane thickness on supported liquid membrane extractions in-line coupled to capillary electrophoresis for analyses of complex samples. J Chromatogr A 2019; 1596:226-232. [DOI: 10.1016/j.chroma.2019.02.067] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 02/25/2019] [Accepted: 02/27/2019] [Indexed: 11/16/2022]
|
41
|
Herce-Sesa B, López-López JA, Moreno C. Multi-elemental ionic liquid-based solvent bar micro-extraction of priority and emerging trace metallic pollutants (Cd, Ag, Pd) in natural waters. JOURNAL OF HAZARDOUS MATERIALS 2019; 370:63-69. [PMID: 29456129 DOI: 10.1016/j.jhazmat.2018.02.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 02/06/2018] [Accepted: 02/11/2018] [Indexed: 06/08/2023]
Abstract
Transition metals Cd, Pd and Ag are toxic even at very low concentration. Cd is considered a priority substance; while, Pd and Ag are emerging pollutants. Membrane technologies have been applied for their extraction; however, they require important amounts of reagents, time and energy. Additionally, effective reagents for metal extraction in saline natural waters are limited. In this case, hollow fiber liquid phase micro-extraction with a configuration of solvent bar (SBME) using the ionic liquid Cyphos® 101 as extractant is proposed. Optimized conditions for SBME of Cd, Ag and Pd were 50% Cyphos® 101 in the organic solution, extraction time 30 min and 800 rpm stirring rate. Leaching was in all cases lower than 0.1%. Metallic concentrations were measured by flame atomic absorption spectroscopy. The method was applied to the extraction of Ag, Cd and Pd in natural water samples. Except for waste water, Pd extraction was higher than 90% in all cases. Cd (≈100%) and Ag (93-95%) offered their best results for saline samples. Concluding, the proposed system is a low cost and green methodology that allows a simple and fast extraction of trace pollutants such as Ag, Cd and Pd in different natural waters, including highly saline samples.
Collapse
Affiliation(s)
- Belén Herce-Sesa
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, University of Cádiz, Puerto Real, 11510 Cádiz, Spain
| | - José A López-López
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, University of Cádiz, Puerto Real, 11510 Cádiz, Spain.
| | - Carlos Moreno
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, University of Cádiz, Puerto Real, 11510 Cádiz, Spain
| |
Collapse
|
42
|
Ali I, Suhail M, Alharbi OML, Hussain I. Advances in sample preparation in chromatography for organic environmental pollutants analyses. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1579739] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Imran Ali
- Department of Chemistry, College of Science, Taibah University, Al-Medina Al-Munawarah, Saudi Arabia
- Department of Chemistry, Jamia Millia Islamia, New Delhi, India
| | - Mohd. Suhail
- Department of Chemistry, Jamia Millia Islamia, New Delhi, India
| | - Omar M. L. Alharbi
- Department of Biology, College of Science, Taibah University, Al-Medina Al-Munawarah, Saudi Arabia
| | - Iqbal Hussain
- Department of General Studies, Jubail Industrial College, Jubail Industrial City, Saudi Arabia
| |
Collapse
|
43
|
Aguirre MÁ, Baile P, Vidal L, Canals A. Metal applications of liquid-phase microextraction. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.11.032] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
44
|
A review of the application of hollow-fiber liquid-phase microextraction in bioanalytical methods – A systematic approach with focus on forensic toxicology. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1108:32-53. [DOI: 10.1016/j.jchromb.2019.01.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 12/10/2018] [Accepted: 01/08/2019] [Indexed: 02/07/2023]
|
45
|
Abstract
The sample preparation is the most critical step involved in the bioanalytical process. When dealing with green analytical chemistry, sample preparation can be even more challenging. To fit the green analytical chemistry principles, efforts should be made toward the elimination or reduction of the use of toxic reagents and solvents, minimization of energy consumption and increased operator safety. The simplest sample preparations are more appropriate for liquid biological matrices with little interfering compounds such as urine, plasma and oral fluid. The same does not usually occur with complex matrices that require more laborious procedures. The present review discusses green analytical approaches for the analyses of drugs of abuse in complex biological matrices, such as whole blood, breast milk, meconium and hair.
Collapse
|
46
|
Abstract
Saliva, as the first body fluid encountering with the exogenous materials, has good correlation with blood and plays an important role in bioanalysis. However, saliva has not been studied as much as the other biological fluids mainly due to restricted access to its large volumes. In recent years, there is a growing interest for saliva analysis owing to the emergence of miniaturized sample preparation methods. The purpose of this paper is to review all microextraction methods and their principles of operation. In the following, we examine the methods used to analyze saliva up to now and discuss the potential of the other microextraction methods for saliva analysis to encourage research groups for more focus on this important subject area.
Collapse
|
47
|
Zarghampour F, Yamini Y, Baharfar M, Faraji M. Simultaneous extraction of acidic and basic drugs via on-chip electromembrane extraction using a single-compartment microfluidic device. Analyst 2019; 144:1159-1166. [DOI: 10.1039/c8an01668b] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
A chip was designed for simultaneous extraction of acidic and basic drugs from biological fluids.
Collapse
Affiliation(s)
| | - Yadollah Yamini
- Department of Chemistry
- Faculty of Sciences
- Tarbiat Modares University
- Tehran
- Iran
| | - Mahroo Baharfar
- Department of Chemistry
- Faculty of Sciences
- Tarbiat Modares University
- Tehran
- Iran
| | - Mohammad Faraji
- Faculty of Food Industry and Agriculture
- Department of Food Science & Technology
- Standard Research Institute (SRI)
- Karaj
- Iran
| |
Collapse
|
48
|
Lemos VA, Oliveira RV, Lopes dos Santos WN, Menezes RM, Santos LB, Costa Ferreira SL. Liquid phase microextraction associated with flow injection systems for the spectrometric determination of trace elements. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.11.031] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
49
|
Havlikova M, Cabala R, Pacakova V, Bosakova Z. Critical evaluation of microextraction pretreatment techniques-Part 2: Membrane-supported and homogenous phase based techniques. J Sep Sci 2018; 42:303-318. [DOI: 10.1002/jssc.201800903] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 10/08/2018] [Accepted: 10/09/2018] [Indexed: 12/22/2022]
Affiliation(s)
- Martina Havlikova
- Department of Analytical Chemistry; Faculty of Science; Charles University; Prague Czech Republic
| | - Radomir Cabala
- Department of Analytical Chemistry; Faculty of Science; Charles University; Prague Czech Republic
- Toxicology Department; Institute of Forensic Medicine and Toxicology; General University Hospital in Prague and 1st Faculty of Medicine of Charles University; Prague Czech Republic
| | - Vera Pacakova
- Department of Analytical Chemistry; Faculty of Science; Charles University; Prague Czech Republic
| | - Zuzana Bosakova
- Department of Analytical Chemistry; Faculty of Science; Charles University; Prague Czech Republic
| |
Collapse
|
50
|
Seidi S, Rezazadeh M, Yamini Y. Pharmaceutical applications of liquid-phase microextraction. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.09.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|