1
|
Mirlohi MS, Pishbin E, Dezhkam R, Kiani MJ, Shamloo A, Salami S. Innovative PNA-LB mediated allele-specific LAMP for KRAS mutation profiling on a compact lab-on-a-disc device. Talanta 2024; 276:126224. [PMID: 38772176 DOI: 10.1016/j.talanta.2024.126224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 04/24/2024] [Accepted: 05/05/2024] [Indexed: 05/23/2024]
Abstract
Tailored healthcare, an approach focused on individual patients, requires integrating emerging interdisciplinary technologies to develop accurate and user-friendly diagnostic tools. KRAS mutations, prevalent in various common cancers, are crucial determinants in selecting patients for novel KRAS inhibitor therapies. This study presents a novel state-of-the-art Lab-on-a-Disc system utilizing peptide nucleic acids-loop backward (PNA-LB) mediated allele-specific loop-mediated isothermal amplification (LAMP) for detecting the frequent G12D KRAS mutation, signifying its superiority over alternative mutation detection approaches. The designed Lab-on-a-Disc system demonstrated exceptional preclinical and technical precision, accuracy, and versatility. By applying varying cutoff values to PNA- LB LAMP reactions, the assay's sensitivity and specificity were increased by 80 % and 90 %, respectively. The device's key advantages include a robust microfluidic Lab-on-a-Disc design, precise rotary control, and a cutting-edge induction heating module. These features enable multiplexing of LAMP reactions with high reproducibility and repeatability, with CV% values less than 3.5 % and 5.5 %, respectively. The device offers several methods for accurate endpoint result detection, including naked-eye observation, RGB image analysis using Python code, and time of fluorescence (Tf) values. Preclinical specificity and sensitivity, assessed using different cutoffs for Eva-Green fluorescence Tf values and pH-sensitive dyes, demonstrated comparable performance to the best standard methods. Overall, this study represents a significant step towards tailoring treatment strategies for cancer patients through precise and efficient mutation detection technologies.
Collapse
Affiliation(s)
- Maryam Sadat Mirlohi
- Clinical Biochemistry Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Esmail Pishbin
- Bio-microfluidics Laboratory, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran.
| | - Rasool Dezhkam
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Mohammad Javad Kiani
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Siamak Salami
- Clinical Biochemistry Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
2
|
Enhanced asymmetric blocked qPCR method for affordable detection of point mutations in KRAS oncogene. Anal Bioanal Chem 2021; 413:2961-2969. [PMID: 33619642 DOI: 10.1007/s00216-021-03229-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 02/05/2021] [Accepted: 02/09/2021] [Indexed: 10/22/2022]
Abstract
An accurate genetic diagnostic is key for adequate patient management and the suitability of healthcare systems. The scientific challenge lies in developing methods to discriminate those patients with certain genetic variations present in tumor cells at low concentrations. We report a method called enhanced asymmetric blocked qPCR (EAB-qPCR) that promotes the blocker annealing against the primer-template hybrid controlling thermal cycling and reaction conditions with nonmodified oligonucleotides. Real-time fluorescent amplification curves of wild-type alleles were delayed by about eight cycles for EAB-qPCR, compared to conventional blocked qPCR approaches. This method reduced the amplification of native DNA variants (blocking percentage 99.7%) and enabled the effective enrichment of low-level DNA mutations. Excellent performance was estimated for the detection of mutated alleles in sensitivity (up to 0.5% mutant/total DNA) and reproducibility terms, with a relative standard deviation below 2.8%. The method was successfully applied to the mutational analysis of metastatic colorectal carcinoma from biopsied tissues. The determined single-nucleotide mutations in the KRAS oncogene (codon 12-13) totally agreed with those obtained from next-generation sequencing. EAB-qPCR is an accurate cheap method and can be easily incorporated into daily routine to detect mutant alleles. Hence, these features are especially interesting to facilitate the diagnosis and prognosis of several clinical diseases.
Collapse
|
3
|
Maciel Braga LA, Mota FB. Early cancer diagnosis using lab-on-a-chip devices : A bibliometric and network analysis. COLLNET JOURNAL OF SCIENTOMETRICS AND INFORMATION MANAGEMENT 2021. [DOI: 10.1080/09737766.2021.1949949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Luiza Amara Maciel Braga
- Faculty of Economics, Fluminense Federal University, Prof. Marcos Waldemar de Freitas Reis Street, 24210-200, Brazil,
| | - Fabio Batista Mota
- Center for Strategic Studies, Oswaldo Cruz Foundation, Brasil Avenue 4036, 21040-361, Brazil
| |
Collapse
|
4
|
Abstract
Lab-on-a-Disc (LoaD) biosensors are increasingly a promising solution for many biosensing applications. In the search for a perfect match between point-of-care (PoC) microfluidic devices and biosensors, the LoaD platform has the potential to be reliable, sensitive, low-cost, and easy-to-use. The present global pandemic draws attention to the importance of rapid sample-to-answer PoC devices for minimising manual intervention and sample manipulation, thus increasing the safety of the health professional while minimising the chances of sample contamination. A biosensor is defined by its ability to measure an analyte by converting a biological binding event to tangible analytical data. With evolving manufacturing processes for both LoaDs and biosensors, it is becoming more feasible to embed biosensors within the platform and/or to pair the microfluidic cartridges with low-cost detection systems. This review considers the basics of the centrifugal microfluidics and describes recent developments in common biosensing methods and novel technologies for fluidic control and automation. Finally, an overview of current devices on the market is provided. This review will guide scientists who want to initiate research in LoaD PoC devices as well as providing valuable reference material to researchers active in the field.
Collapse
|
5
|
Madadelahi M, Acosta-Soto LF, Hosseini S, Martinez-Chapa SO, Madou MJ. Mathematical modeling and computational analysis of centrifugal microfluidic platforms: a review. LAB ON A CHIP 2020; 20:1318-1357. [PMID: 32242566 DOI: 10.1039/c9lc00775j] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Centrifugal microfluidic platforms or lab-on-discs (LODs) have evolved into a popular technology for automating chemical and biological assays. LODs today enable scientists to implement and integrate different operational units, including fluid mixing, droplet generation, cell-sorting, gene amplification, analyte detection, and so forth. For an efficient design and cost-effective implementation of any microfluidic device, including LODs, theoretical analysis and considerations should play a more important role than they currently do. The theoretical analysis we will show is especially essential to the investigation of detailed phenomena at the small length scales and high-speed typical for LODs where a wide range of forces may be involved. Previous LOD review papers presented mostly experimental results with theory as an afterthought. Hence, a review paper focused on the theoretical aspects, and associated computational studies of LOD devices is an urgent need. In the present review paper, all previous computational studies on LOD devices are categorized as single-phase flows, two-phase flows, network simulation, and solids. For each of these categories, the governing equations and important formulas are presented and explained. Moreover, a handy scaling analysis is introduced to aid scientists when comparing different competing forces in LOD devices. We hope that by surveying and contrasting various theoretical LOD studies, we shed some light on existing controversies and reveal where additional theoretical work is needed.
Collapse
Affiliation(s)
- Masoud Madadelahi
- School of Engineering and Sciences, Tecnologico de Monterrey, Ave. Eugenio Garza Sada 2501, Monterrey 64849, NL, Mexico.
| | | | | | | | | |
Collapse
|
6
|
Li L, Miao B, Li Z, Sun Z, Peng N. Sample-to-Answer Hepatitis B Virus DNA Detection from Whole Blood on a Centrifugal Microfluidic Platform with Double Rotation Axes. ACS Sens 2019; 4:2738-2745. [PMID: 31502439 DOI: 10.1021/acssensors.9b01270] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A point-of-care apparatus for hepatitis virus detection requires simple and easy-to-use processing steps and should have the same diagnostic capability as that in the central laboratory. However, no automated and efficient methods for hepatitis B virus (HBV) sample-to-answer detection include serum separation, and complete prestorage of reagents has been developed. We developed an automated sample-to-answer disc for rapid HBV detection from whole blood based on a double rotation axes centrifugal microfluidic platform. The disc with complete prestorage of reagents features fully automated and integrated serum separation from whole blood, magnetic bead-based DNA extraction, aliquoting of the nucleic acid, and real-time polymerase chain reaction. A laser diode for sequential release of prestored liquid reagents was used. Processing merely requires manual loading of the sample into the disc. We demonstrate successful sample-to-answer detection of HBV in a 500 μL whole blood sample with sample concentrations down to 102 copies/mL. The total time of the whole detection from sample-to-result is about 48 min. The disc provides a user-friendly molecular diagnostic system for rapid analysis of HBV without demanding a complicated laboratory instrument and major manual operation time. Overall, the results indicated that the developed disc could be used for HBV molecular diagnosis.
Collapse
Affiliation(s)
- Lei Li
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710054, Shaanxi, China
| | - Baogang Miao
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710054, Shaanxi, China
| | - Zheng Li
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710054, Shaanxi, China
| | - Zhengming Sun
- Shaanxi Provincial People’s Hospital, Xi’an 710068, Shaanxi, China
| | - Niancai Peng
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710054, Shaanxi, China
| |
Collapse
|
7
|
The mechanism of the adsorption of dsDNA on citrate-stabilized gold nanoparticles and a colorimetric and visual method for detecting the V600E point mutation of the BRAF gene. Mikrochim Acta 2018; 185:240. [PMID: 29594675 DOI: 10.1007/s00604-018-2775-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 03/15/2018] [Indexed: 10/17/2022]
Abstract
A study is presented on the binding kinetics and mechanism of the adsorption of dsDNA on citrate-capped gold nanoparticles (AuNPs). Methods include fluorescence titration, isothermal calorimetry (ITC) titration, dynamic light scattering and gel electrophoresis. It is found that the fluorescence of probe DNA (labeled with Rhodamine Green and measured at excitation/emission peaks of 498/531 nm) is quenched by addition of AuNPs. The Stern-Volmer quenching constant (Ksv) is 1.67 × 10^9 L·mol-1 at 308 K and drops with increasing temperature. The quenching mechanism is mainly static. The results of both fluorescence titrations and ITC show negative values for ΔH and ΔS values. This shows ion-induced dipole-dipole interaction to be the main attractive forces between dsDNA and AuNPs, while electrostatic interactions result in repulsion. The repulsive forces lead to a lower affinity between dsDNA and AuNPs (compared to single-strand DNA). It is also found that dsDNA can prevent the aggregation of AuNPs which is accompanied by a color change from red into blue. The visual detection limit with bare eyes for dsDNA1 is 36 pM. Based on these findings, a colorimetric method was developed to detect the proto-oncogene of serine/threonine-protein kinase B-Raf V600E point mutation in HT29, Ec109, A549, Huh-7 and SW480 cell lines. Graphical abstract Schematic of the salt-induced aggregation of uncapped gold nanoparticles (AuNPs) which leads to a color change from red to blue. If the AuNPs are coated with dsDNA, aggregation is suppressed.
Collapse
|
8
|
Heidari Sharafdarkolaei S, Motovali-Bashi M, Gill P. Fluorescent detection of point mutation via ligase reaction assisted by quantum dots and magnetic nanoparticle-based probes. RSC Adv 2017. [DOI: 10.1039/c7ra03767h] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A nanodiagnostic genotyping method was presented for point mutation detection directly in human genomic DNA based on ligase reaction coupled with quantum dots and magnetic nanoparticle-based probes.
Collapse
Affiliation(s)
| | | | - P. Gill
- Nanomedicine Group
- Immunogenetics Research Center
- Mazandaran University of Medical Sciences
- Sari
- Iran
| |
Collapse
|
9
|
Ahrberg CD, Manz A, Chung BG. Polymerase chain reaction in microfluidic devices. LAB ON A CHIP 2016; 16:3866-3884. [PMID: 27713993 DOI: 10.1039/c6lc00984k] [Citation(s) in RCA: 138] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The invention of the polymerase chain reaction (PCR) has caused a revolution in molecular biology, giving access to a method of amplifying deoxyribonucleic acid (DNA) molecules across several orders of magnitude. Since the first application of PCR in a microfluidic device was developed in 1998, an increasing number of researchers have continued the development of microfluidic PCR systems. In this review, we introduce recent developments in microfluidic-based space and time domain devices as well as discuss various designs integrated with multiple functions for sample preparation and detection. The development of isothermal nucleic acid amplification and digital PCR microfluidic devices within the last five years is also highlighted. Furthermore, we introduce various commercial microfluidic PCR devices.
Collapse
Affiliation(s)
| | - Andreas Manz
- Microfluidics group, KIST-Europe, Saarbrücken, Germany and Mechanotronics Department, Universität des Saarlandes, Saarbrücken, Germany
| | - Bong Geun Chung
- Department of Mechanical Engineering, Sogang University, Seoul, Korea.
| |
Collapse
|
10
|
Kong LX, Perebikovsky A, Moebius J, Kulinsky L, Madou M. Lab-on-a-CD. ACTA ACUST UNITED AC 2016; 21:323-55. [DOI: 10.1177/2211068215588456] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Indexed: 12/14/2022]
|
11
|
Stumpf F, Schwemmer F, Hutzenlaub T, Baumann D, Strohmeier O, Dingemanns G, Simons G, Sager C, Plobner L, von Stetten F, Zengerle R, Mark D. LabDisk with complete reagent prestorage for sample-to-answer nucleic acid based detection of respiratory pathogens verified with influenza A H3N2 virus. LAB ON A CHIP 2016; 16:199-207. [PMID: 26610171 DOI: 10.1039/c5lc00871a] [Citation(s) in RCA: 85] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Portable point-of-care devices for pathogen detection require easy, minimal and user-friendly handling steps and need to have the same diagnostic performance compared to centralized laboratories. In this work we present a fully automated sample-to-answer detection of influenza A H3N2 virus in a centrifugal LabDisk with complete prestorage of reagents. Thus, the initial supply of the sample remains the only manual handling step. The self-contained LabDisk automates by centrifugal microfluidics all necessary process chains for PCR-based pathogen detection: pathogen lysis, magnetic bead based nucleic acid extraction, aliquoting of the eluate into 8 reaction cavities, and real-time reverse transcription polymerase chain reaction (RT-PCR). Prestored reagents comprise air dried specific primers and fluorescence probes, lyophilized RT-PCR mastermix and stick-packaged liquid reagents for nucleic acid extraction. Employing two different release frequencies for the stick-packaged liquid reagents enables on-demand release of highly wetting extraction buffers, such as sequential release of lysis and binding buffer. Microfluidic process-flow was successful in 54 out of 55 tested LabDisks. We demonstrate successful detection of the respiratory pathogen influenza A H3N2 virus in a total of 18 LabDisks with sample concentrations down to 2.39 × 10(4) viral RNA copies per ml, which is in the range of clinical relevance. Furthermore, we detected RNA bacteriophage MS2 acting as internal control in 3 LabDisks with a sample concentration down to 75 plaque forming units (pfu) per ml. All experiments were applied in a 2 kg portable, laptop controlled point-of-care device. The turnaround time of the complete analysis from sample-to-answer was less than 3.5 hours.
Collapse
Affiliation(s)
- F Stumpf
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Keller M, Naue J, Zengerle R, von Stetten F, Schmidt U. Automated Forensic Animal Family Identification by Nested PCR and Melt Curve Analysis on an Off-the-Shelf Thermocycler Augmented with a Centrifugal Microfluidic Disk Segment. PLoS One 2015; 10:e0131845. [PMID: 26147196 PMCID: PMC4492497 DOI: 10.1371/journal.pone.0131845] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2015] [Accepted: 06/05/2015] [Indexed: 11/19/2022] Open
Abstract
Nested PCR remains a labor-intensive and error-prone biomolecular analysis. Laboratory workflow automation by precise control of minute liquid volumes in centrifugal microfluidic Lab-on-a-Chip systems holds great potential for such applications. However, the majority of these systems require costly custom-made processing devices. Our idea is to augment a standard laboratory device, here a centrifugal real-time PCR thermocycler, with inbuilt liquid handling capabilities for automation. We have developed a microfluidic disk segment enabling an automated nested real-time PCR assay for identification of common European animal groups adapted to forensic standards. For the first time we utilize a novel combination of fluidic elements, including pre-storage of reagents, to automate the assay at constant rotational frequency of an off-the-shelf thermocycler. It provides a universal duplex pre-amplification of short fragments of the mitochondrial 12S rRNA and cytochrome b genes, animal-group-specific main-amplifications, and melting curve analysis for differentiation. The system was characterized with respect to assay sensitivity, specificity, risk of cross-contamination, and detection of minor components in mixtures. 92.2% of the performed tests were recognized as fluidically failure-free sample handling and used for evaluation. Altogether, augmentation of the standard real-time thermocycler with a self-contained centrifugal microfluidic disk segment resulted in an accelerated and automated analysis reducing hands-on time, and circumventing the risk of contamination associated with regular nested PCR protocols.
Collapse
Affiliation(s)
- Mark Keller
- Laboratory for MEMS Applications, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
- Hahn-Schickard, Freiburg, Germany
| | - Jana Naue
- Institute of Legal Medicine, Freiburg University Medical Center, Freiburg, Germany
- Faculty of Biology, University of Freiburg, Freiburg, Germany
| | - Roland Zengerle
- Laboratory for MEMS Applications, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
- Hahn-Schickard, Freiburg, Germany
- BIOSS–Centre for Biological Signalling Studies, University of Freiburg, Freiburg, Germany
| | - Felix von Stetten
- Laboratory for MEMS Applications, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
- Hahn-Schickard, Freiburg, Germany
| | - Ulrike Schmidt
- Institute of Legal Medicine, Freiburg University Medical Center, Freiburg, Germany
- * E-mail:
| |
Collapse
|
13
|
Keller M, Wadle S, Paust N, Dreesen L, Nuese C, Strohmeier O, Zengerle R, von Stetten F. Centrifugo-thermopneumatic fluid control for valving and aliquoting applied to multiplex real-time PCR on off-the-shelf centrifugal thermocycler. RSC Adv 2015. [DOI: 10.1039/c5ra16095b] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Microfluidic App for automation of geometrically multiplexed real-time PCR on off-the-shelf PCR thermocycler.
Collapse
Affiliation(s)
- M. Keller
- Hahn-Schickard-Gesellschaft für angewandte Forschung e.V
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - S. Wadle
- Hahn-Schickard-Gesellschaft für angewandte Forschung e.V
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - N. Paust
- Hahn-Schickard-Gesellschaft für angewandte Forschung e.V
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - L. Dreesen
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
- University of Freiburg
- 79110 Freiburg
- Germany
| | - C. Nuese
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
- University of Freiburg
- 79110 Freiburg
- Germany
| | - O. Strohmeier
- Hahn-Schickard-Gesellschaft für angewandte Forschung e.V
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - R. Zengerle
- Hahn-Schickard-Gesellschaft für angewandte Forschung e.V
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - F. von Stetten
- Hahn-Schickard-Gesellschaft für angewandte Forschung e.V
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| |
Collapse
|
14
|
Strohmeier O, Keil S, Kanat B, Patel P, Niedrig M, Weidmann M, Hufert F, Drexler J, Zengerle R, von Stetten F. Automated nucleic acid extraction from whole blood, B. subtilis, E. coli, and Rift Valley fever virus on a centrifugal microfluidic LabDisk. RSC Adv 2015. [DOI: 10.1039/c5ra03399c] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
We present total nucleic acid extraction from whole blood, Gram-positiveBacillus subtilis, Gram-negativeEscherichia coli, andRift Valley feverRNA virus on a low-cost, centrifugal microfluidic cartridge processed in a portable processing device.
Collapse
Affiliation(s)
- O. Strohmeier
- HSG-IMIT-Institut für Mikro- und Informationstechnik
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK-Department of Microsystems Engineering
| | - S. Keil
- HSG-IMIT-Institut für Mikro- und Informationstechnik
- 79110 Freiburg
- Germany
| | - B. Kanat
- HSG-IMIT-Institut für Mikro- und Informationstechnik
- 79110 Freiburg
- Germany
| | - P. Patel
- Centre for Biological Threats and Special Pathogens 1
- Robert Koch-Institute
- 13353 Berlin
- Germany
| | - M. Niedrig
- Centre for Biological Threats and Special Pathogens 1
- Robert Koch-Institute
- 13353 Berlin
- Germany
| | - M. Weidmann
- Institute of Aquaculture
- University of Stirling
- FK9 4LA Stirling
- UK
| | - F. Hufert
- Institute of Microbiology and Virology
- Brandenburg Medical School Theodor Fontane
- Germany
| | - J. Drexler
- QIAGEN Lake Constance GmbH
- 78333 Stockach
- Germany
| | - R. Zengerle
- HSG-IMIT-Institut für Mikro- und Informationstechnik
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK-Department of Microsystems Engineering
| | - F. von Stetten
- HSG-IMIT-Institut für Mikro- und Informationstechnik
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK-Department of Microsystems Engineering
| |
Collapse
|
15
|
Strohmeier O, Keller M, Schwemmer F, Zehnle S, Mark D, von Stetten F, Zengerle R, Paust N. Centrifugal microfluidic platforms: advanced unit operations and applications. Chem Soc Rev 2015; 44:6187-229. [DOI: 10.1039/c4cs00371c] [Citation(s) in RCA: 290] [Impact Index Per Article: 32.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Review on miniaturization, integration, and automation of laboratory processes within centrifugal microfluidic platforms. For efficient implementation of applications, building blocks are categorized into unit operations and process chains.
Collapse
Affiliation(s)
- O. Strohmeier
- Hahn-Schickard
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - M. Keller
- Hahn-Schickard
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - F. Schwemmer
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
- University of Freiburg
- 79110 Freiburg
- Germany
| | | | - D. Mark
- Hahn-Schickard
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - F. von Stetten
- Hahn-Schickard
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - R. Zengerle
- Hahn-Schickard
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| | - N. Paust
- Hahn-Schickard
- 79110 Freiburg
- Germany
- Laboratory for MEMS Applications
- IMTEK – Department of Microsystems Engineering
| |
Collapse
|
16
|
Real-time stability testing of air-dried primers and fluorogenic hydrolysis probes stabilized by trehalose and xanthan. Biotechniques 2014; 57:151-5. [PMID: 25209050 DOI: 10.2144/000114207] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2014] [Accepted: 08/01/2014] [Indexed: 11/23/2022] Open
Abstract
A method for conserving primers and differently labeled fluorogenic hydrolysis (i.e., TaqMan) probes at ambient conditions is presented. Primers and hydrolysis probes with four different fluorophore-quencher combinations (6- FAM-BHQ1, HEX-BHQ1, ROX-BHQ650, and Cy5-BHQ2) were mixed with trehalose and xanthan at final concentrations of 56 mM and 2.78 mM, respectively. Mixtures were air-dried at 23°C for 30 min on strips composed of cyclo olefin polymer (COP), a material widely used in the manufacturing of in vitro diagnostic (IVD) test carriers. After one year of storage, the functionality of the primers and fluorophore-quencher combinations was validated by real-time polymerase chain reaction (real-time PCR), confirming their stability when stored in the presence of stabilizers, with the best results achieved using trehalose. This approach could be of great benefit for manufacturing IVD systems, for example, for genotyping applications based on multiplexing using different fluorescent dyes.
Collapse
|