1
|
Falkowski M, Leda A, Hassani M, Wicinski M, Mlynarczyk DT, Düzgüneş N, Marszall MP, Milczarek G, Piskorz J, Rębiś T. Manganese Sulfanyl Porphyrazine-MWCNT Nanohybrid Electrode Material as a Catalyst for H 2O 2 and Glucose Biosensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:6257. [PMID: 39409297 PMCID: PMC11478948 DOI: 10.3390/s24196257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Revised: 09/19/2024] [Accepted: 09/20/2024] [Indexed: 10/20/2024]
Abstract
The demetallation reaction of sulfanyl magnesium(II) porphyrazine with N-ethylphthalimide substituents, followed by remetallation with manganese(II) salts, yields the corresponding manganese(III) derivative (Pz3) with high efficiency. This novel manganese(III) sulfanyl porphyrazine was characterized by HPLC and analyzed using UV-Vis, MS, and FT-IR spectroscopy. Electrochemical experiments of Pz3 conducted in dichloromethane revealed electrochemical activity of the new complex due to both manganese and N-ethylphthalimide substituents redox transitions. Subsequently, Pz3 was deposited on multiwalled carbon nanotubes (MWCNTs), and this hybrid material was then applied to glassy carbon electrodes (GC). The resulting hybrid electroactive electrode material, combining manganese(III) porphyrazine with MWCNTs, showed a significant decrease in overpotential of H2O2 oxidation compared to bare GC or GC electrodes modified with only carbon nanotubes (GC/MWCNTs). This improvement, attributed to the electrocatalytic performance of Mn3+, enabled linear response and sensitive detection of H2O2 at neutral pH. Furthermore, a glucose oxidase (GOx)-containing biosensing platform was developed by modifying the prepared GC/MWCNT/Pz3 electrode for the electrochemical detection of glucose. The bioelectrode incorporating the newly designed Pz3 exhibited good activity in the presence of glucose, confirming effective electronic communication between the Pz3, GOx and MWCNT surface. The linear range for glucose detection was 0.2-3.7 mM.
Collapse
Affiliation(s)
- Michal Falkowski
- Department of Medicinal Chemistry, Collegium Medicum in Bydgoszcz, Faculty of Pharmacy, Nicolaus Copernicus University in Torun, Dr. A. Jurasza 2, 85-089 Bydgoszcz, Poland; (M.H.); (M.P.M.)
- Faculty of Health Sciences, Collegium Medicum, The Mazovian University in Płock, 09-402 Płock, Poland
| | - Amanda Leda
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland; (A.L.); (G.M.)
| | - Mina Hassani
- Department of Medicinal Chemistry, Collegium Medicum in Bydgoszcz, Faculty of Pharmacy, Nicolaus Copernicus University in Torun, Dr. A. Jurasza 2, 85-089 Bydgoszcz, Poland; (M.H.); (M.P.M.)
| | - Michal Wicinski
- Department of Pharmacology and Therapy, Collegium Medicum in Bydgoszcz, Faculty of Medicine, Nicolaus Copernicus University in Torun, Curie Sklodowskiej 9, 85-094 Bydgoszcz, Poland;
| | - Dariusz T. Mlynarczyk
- Chair and Department of Chemical Technology of Drugs, Poznan University of Medical Sciences, Rokietnicka 3, 60-806 Poznan, Poland
| | - Nejat Düzgüneş
- Department of Biomedical Sciences, Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, CA 94103, USA;
| | - Michal P. Marszall
- Department of Medicinal Chemistry, Collegium Medicum in Bydgoszcz, Faculty of Pharmacy, Nicolaus Copernicus University in Torun, Dr. A. Jurasza 2, 85-089 Bydgoszcz, Poland; (M.H.); (M.P.M.)
| | - Grzegorz Milczarek
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland; (A.L.); (G.M.)
| | - Jaroslaw Piskorz
- Chair and Department of Inorganic and Analytical Chemistry, Poznan University of Medical Sciences, Rokietnicka 3, 60-806 Poznan, Poland;
| | - Tomasz Rębiś
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland; (A.L.); (G.M.)
| |
Collapse
|
2
|
Li H, Xiao N, Jiang M, Long J, Li Z, Zhu Z. Advances of Transition Metal-Based Electrochemical Non-enzymatic Glucose Sensors for Glucose Analysis: A Review. Crit Rev Anal Chem 2024:1-37. [PMID: 38635407 DOI: 10.1080/10408347.2024.2339955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Glucose concentration is a crucial parameter for assessing human health. Over recent years, non-enzymatic electrochemical glucose sensors have drawn considerable attention due to their substantial progress. This review explores the common mechanism behind the transition metal-based electrocatalytic oxidation of glucose molecules through classical electrocatalytic frameworks like the Pletcher model and the Hydrous Oxide-Adatom Mediator model (IHOAM), as well as the redox reactions at the transition metal centers. It further compiles the electrochemical characterization techniques, associated formulas, and their ensuing conclusions pertinent to transition metal-based non-enzymatic electrochemical glucose sensors. Subsequently, the review covers the latest advancements in the field of transition metal-based active materials and support materials used in non-enzymatic electrochemical glucose sensors in the last decade (2014-2023). Additionally, it presents a comprehensive classification of representative studies according to the active metal catalysts components involved.
Collapse
Affiliation(s)
- Haotian Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Nan Xiao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Mengyi Jiang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Jianjun Long
- Danyang Development Zone, Jiangsu Yuwell-POCT Biological Technology Co., Ltd, Danyang, China
| | - Zhanhong Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
3
|
Thakur AK, Sengodu P, Jadhav AH, Malmali M. Manganese Carbonate/Laser-Induced Graphene Composite for Glucose Sensing. ACS OMEGA 2024; 9:7869-7880. [PMID: 38405531 PMCID: PMC10882677 DOI: 10.1021/acsomega.3c07642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 12/22/2023] [Accepted: 01/04/2024] [Indexed: 02/27/2024]
Abstract
Laser-induced graphene (LIG) has received great interest as a potential candidate for electronic and sensing applications. In the present study, we report the enhanced performance of a manganese carbonate-decorated LIG (MnCO3/LIG) composite electrode material employed for electrochemical glucose detection. Initially, the porous LIG was fabricated by directly lasing poly(ether sulfone) membrane substrate. Then, the MnCO3/LIG composite was synthesized via a hydrothermal method. Later, MnCO3/LIG was immobilized onto a glassy carbon electrode surface and employed for glucose detection. The structure of the MnCO3/LIG composite was carefully characterized. The influence of the MnCO3/LIG composite on the performance of the electrode was investigated using cyclic voltammetry curves. The MnCO3/LIG composite exhibited an excellent sensitivity of 2731.2 μA mM-1 cm-2, and a limit of detection of 2.2 μM was obtained for the detection of glucose. Overall, the performance of the MnCO3/LIG composite was found to be superior to that of most of the MnCO3-based composites.
Collapse
Affiliation(s)
- Amit K. Thakur
- Department
of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Prakash Sengodu
- Department
of Industrial Chemistry, School of Chemical Sciences, Alagappa University, Karaikudi, Tamil Nadu 630003, India
| | - Arvind H. Jadhav
- Centre
for Nano and Material Science (CNMS), Jain
University, Bangalore 562112, India
| | - Mahdi Malmali
- Department
of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| |
Collapse
|
4
|
Farahmandpour M, Haghshenas H, Kordrostami Z. Blood glucose sensing by back gated transistor strips sensitized by CuO hollow spheres and rGO. Sci Rep 2022; 12:21872. [PMID: 36536057 PMCID: PMC9763381 DOI: 10.1038/s41598-022-26287-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
In this work, a highly sensitive flexible glucose sensor based on a field effect transistor (FET) has been fabricated. It is shown that the proposed flexible transistor can be used as new non-enzymatic blood glucose test strips. CuO hollow-spheres decorated with reduced graphene oxide have been synthesized using the hydrothermal method. The shells of the hollow micro-spheres are formed by nanostructures. The synthesized nanostructured hollow micro-spheres (rGO/CuO-NHS) are deposited on a flexible PET substrate between interdigitated electrodes as the channel of a back gate transistor. The channel concentration and the FET bias are optimized so that the sensor exhibits extremely low limit of detection and high sensitivity. The combination of selective porous CuO hollow spheres and the high surface to volume ratio of their nanostructured shells with the high mobility and high conductivity rGO led to faster and higher charge-transfer capability and superior electro-catalyst activity for glucose oxidation. The glucose-dependent electrical responses of the sensor is measured in both resistive and transistor action modes. The amplification of the current by the induced electric field of the gate in the proposed FET-based biosensor provides advantages such as higher sensitivity and lower limit of detection compared to the resistive sensor. The flexible glucose sensor has a sensitivity of 600 μA μM-1 and a limit of detection of 1 nM with high reproducibility, good stability, and highly selectivity. The high accuracy response of the biosensor towards the real blood serum samples showed that it can be used as a test strip for glucose detection in real blood samples.
Collapse
Affiliation(s)
- Milad Farahmandpour
- grid.444860.a0000 0004 0600 0546Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran ,grid.444860.a0000 0004 0600 0546Research Center for Design and Fabrication of Advanced Electronic Devices, Shiraz University of Technology, Shiraz, Iran
| | - Hassan Haghshenas
- grid.444860.a0000 0004 0600 0546Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran ,grid.444860.a0000 0004 0600 0546Research Center for Design and Fabrication of Advanced Electronic Devices, Shiraz University of Technology, Shiraz, Iran
| | - Zoheir Kordrostami
- grid.444860.a0000 0004 0600 0546Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran ,grid.444860.a0000 0004 0600 0546Research Center for Design and Fabrication of Advanced Electronic Devices, Shiraz University of Technology, Shiraz, Iran
| |
Collapse
|
5
|
Golsanamlou Z, Mahmoudpour M, Soleymani J, Jouyban A. Applications of Advanced Materials for Non-Enzymatic Glucose Monitoring: From Invasive to the Wearable Device. Crit Rev Anal Chem 2021; 53:1116-1131. [PMID: 34894901 DOI: 10.1080/10408347.2021.2008227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Diabetes mellitus (DM) is a global health problem leading to many complications and disabilities in life adjusting activities and even dead. Monitoring glucose levels is a key factor in diagnosis and management of DM. Conventional glucose sensors consisted of immobilized enzymes, are so susceptible to environmental conditions. In this way, nonenzymatic biosensors have attracted extensive attentions in many clinical diagnostics applications. To date, the finger pricking test is a common enzyme-based glucometer that is an invasive and inconvenient and may lead to infections in the injection sites. So, working on the possibility of cutaneous or subcutaneous insertion of devices as a noninvasive or minimally-invasive systems for continuous glucose controlling approaches through human biofluids (blood, perspiration, tears, saliva, etc.) have stimulated growing interest. This review summarizes recent nonenzymatic and noninvasive biofluids glucose monitoring systems which are highly resilience and stretchable to continuously adapt to body movements during common physical activity. Sensors are based on their constituent materials including carbon-based, metal nanoparticles, polymer, and hydrogel systems are classified for electrochemical, and optical glucose detection. Finally, we address the drawbacks and challenges of enzyme-free sensors which are aroused sustaining research passion to be used in point-of-care medical diagnostics applications.
Collapse
Affiliation(s)
- Zahra Golsanamlou
- Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mansour Mahmoudpour
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Jafar Soleymani
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Near East University, Nicosia, Turkey
| |
Collapse
|
6
|
Płócienniczak P, Rębiś T, Leda A, Milczarek G. Lignosulfonate-assisted synthesis of platinum nanoparticles deposited on multi-walled carbon nanotubes for biosensing of glucose. Colloids Surf B Biointerfaces 2021; 210:112222. [PMID: 34836706 DOI: 10.1016/j.colsurfb.2021.112222] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 11/03/2021] [Accepted: 11/12/2021] [Indexed: 10/19/2022]
Abstract
It is presented in this work that lignosulfonate (LS) can be preferentially adsorbed on the surface of multi-walled carbon nanotubes (MWCNT) giving rise to the functional platform for platinum nanoparticles (NPt) deposition. The novel MWCNT/LS/NPt hybrid material has been characterized by X-ray diffraction (XRD), Fourier transformation infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS). The morphology of the MWCNT/LS/NPt electrodes has been investigated by atomic force microscopy (AFM). The electrochemical studies of MWCNT/LS/NPt hybrid material revealed strong electrocatalytic properties towards hydrogen peroxide. In addition, the effects of lignosulfonate amount adsorbed at the MWCNT on the voltammetric response of the hydrogen peroxide were discussed and used to select the optimal and effective conditions for the synthesis of the electrode material. An amperometric biosensor for glucose was developed based on the covalent linkage of glucose oxidase (GOx) at the MWCNT/LS/NPt. The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for glucose. The linear range of the glucose determination was 50-1400 µM and LOD was quantified as 15.67 µM.
Collapse
Affiliation(s)
- Patrycja Płócienniczak
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland
| | - Tomasz Rębiś
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland.
| | - Amanda Leda
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland
| | - Grzegorz Milczarek
- Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland.
| |
Collapse
|
7
|
Rajaji U, Ganesh PS, Chen SM, Govindasamy M, Kim SY, A. Alshgari R, Shimoga G. Deep eutectic solvents synthesis of perovskite type cerium aluminate embedded carbon nitride catalyst: High-sensitive amperometric platform for sensing of glucose in biological fluids. J IND ENG CHEM 2021. [DOI: 10.1016/j.jiec.2021.07.015] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
8
|
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2020025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
Collapse
|
9
|
Rajeev R, Datta R, Varghese A, Sudhakar Y, George L. Recent advances in bimetallic based nanostructures: Synthesis and electrochemical sensing applications. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105910] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
10
|
Peng Q, Zhang Y, Yang S, Yuwen T, Liu Y, Fan J, Zang G. Glucose determination behaviour of gold microspheres-electrodeposited carbon cloth flexible electrodes in neutral media. Anal Chim Acta 2021; 1159:338442. [PMID: 33867044 DOI: 10.1016/j.aca.2021.338442] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/16/2021] [Accepted: 03/18/2021] [Indexed: 11/30/2022]
Abstract
Despite numerous advances in the field of nonenzymatic glucose detection, monitoring glucose in physiological applications is still a challenge and is mostly limited to electrode surface modification. This study proposes a simple method for electrodepositing cotton-like gold microspheres (CGMs) on a carbon cloth (CC) flexible electrode, with the potential for the functional supporting substrate to monitor glucose in a neutral environment. It was demonstrated that the voltammetric response of glucose oxidation increased with increases in glucose concentration in the 3D functional flexible substrate; moreover, the amperometric response of glucose oxidation increased over time. The results indicate that the functional flexible electrode-made of gold microspheres-based carbon cloth with a predefined geometry and pore-architecture network to promote the medium-permeation and synergetic effects between CGMs and CC-can be a suitable platform for measuring glucose variation in environments with neutral pH. This is particularly relevant because the oxygen-containing functional groups on the CC surface increase the dehydrogenation rate of glucose oxidation in neutral phosphate-buffered saline.
Collapse
Affiliation(s)
- Qianyu Peng
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Yuchan Zhang
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Shengfei Yang
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Tianyi Yuwen
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Yangkun Liu
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Jingchuan Fan
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Guangchao Zang
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China.
| |
Collapse
|
11
|
Zhang B, She N, Du J, Zhang M, Fang G, Wang S. Nanocomposites based on quasi-networked Au 1.5Pt 1Co 1 ternary alloy nanoparticles and decorated with poly-L-cysteine film for the electrocatalytic application of hydroquinone sensing. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2021; 207:111251. [PMID: 32905935 DOI: 10.1016/j.ecoenv.2020.111251] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 08/23/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
A mildly one-pot method is developed for the synthesis of quasi-networked Au1.5Pt1Co1 ternary alloy nanoparticles (TANPs) at room temperature through the co-reduction of AuCl4-, PtCl6- and Co2+ with hydrazine hydrate. Characterizations of XRD, XPS, HRTEM, EDS and SAED successfully reveal the crystal structure, composition, valence and morphology of Au1.5Pt1Co1 TANPs, respectively. The glassy carbon electrode (GCE) modified by Au1.5Pt1Co1 TANPs with good dispersion and multi-density surface defects occupies the optimal electrochemical active surface area (ECSA). After the coated poly-L-cysteine (P-L-Cys) film on the Au1.5Pt1Co1/GCE surface, the morphology, element mapping and surface roughness of the P-L-Cys/Au1.5Pt1Co1/GCE are investigated via FESEM and AFM to verify continuous electrode modification processes. The electrochemical behaviors of the composite electrode for hydroquinone (HQ) are evaluated by cyclic voltammetry (CV) with interfacial properties of adsorption and diffusion. Differential pulse voltammetry (DPV) for HQ electrochemical sensing at 0.10 V (vs. SCE) exhibits two linear response ranges from 0.1 to 30 and 30-200 μM, respectively. A low detection limit (S/N = 3) of 0.045 μM is obtained with a sensitivity of 4.247 μA μM-1·cm-2. The resulting P-L-Cys/Au1.5Pt1Co1/GCE also presents ascendant selectivity, repeatability, reproducibility and stability. In addition, the established method is applied to the assessment of the HQ level in real water samples (mineral water, tap water and lake water) with the satisfactory results of spiked recoveries. The sensor may become a promising tool for the trace analysis of the electroactive substance in food or environmental samples.
Collapse
Affiliation(s)
- Bo Zhang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China
| | - Nana She
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China
| | - Jing Du
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China
| | - Meng Zhang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China
| | - Guozhen Fang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China.
| | - Shuo Wang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China; Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin, 300071, China.
| |
Collapse
|
12
|
A Non-Enzymatic Sensor Based on Fc-CHIT/CNT@Cu Nanohybrids for Electrochemical Detection of Glucose. Polymers (Basel) 2020; 12:polym12102419. [PMID: 33092222 PMCID: PMC7589752 DOI: 10.3390/polym12102419] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 10/14/2020] [Accepted: 10/14/2020] [Indexed: 11/26/2022] Open
Abstract
Herein, a composite structure, consisting of Cu nanoparticles (NPs) deposited onto carbon nanotubes and modified with ferrocene-branched chitosan, was prepared in order to develop a nonenzymatic electrochemical glucose biosensor ferrocene-chitosan/carbon nanotube@ Cu (Fc-CHIT/CNT@Cu). The elemental composition of the carbon nanohybrids, morphology and structure were characterized by various techniques. Electrochemical impedance spectroscopy (EIS) was used to study the interfacial properties of the electrodes. Cyclic voltammetry (CV) and chronoamperometry methods in alkaline solution were used to determine glucose biosensing properties. The synergy effect of Cu NPs and Fc on current responses of the developed electrode resulted in good glucose sensitivity, including broad linear detection between 0.2 mM and 22 mM, a low detection limit of 13.52 μM and sensitivity of 1.256 μA mM−1cm−2. Moreover, the modified electrode possessed long-term stability and good selectivity in the presence of ascorbic acid, dopamine and uric acid. The results indicated that this inexpensive electrode had potential application for non-enzymatic electrochemical glucose detection.
Collapse
|
13
|
Teymourian H, Barfidokht A, Wang J. Electrochemical glucose sensors in diabetes management: an updated review (2010-2020). Chem Soc Rev 2020; 49:7671-7709. [PMID: 33020790 DOI: 10.1039/d0cs00304b] [Citation(s) in RCA: 309] [Impact Index Per Article: 61.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
While over half a century has passed since the introduction of enzyme glucose biosensors by Clark and Lyons, this important field has continued to be the focus of immense research activity. Extensive efforts during the past decade have led to major scientific and technological innovations towards tight monitoring of diabetes. Such continued progress toward advanced continuous glucose monitoring platforms, either minimal- or non-invasive, holds considerable promise for addressing the limitations of finger-prick blood testing toward tracking glucose trends over time, optimal therapeutic interventions, and improving the life of diabetes patients. However, despite these major developments, the field of glucose biosensors is still facing major challenges. The scope of this review is to present the key scientific and technological advances in electrochemical glucose biosensing over the past decade (2010-present), along with current obstacles and prospects towards the ultimate goal of highly stable and reliable real-time minimally-invasive or non-invasive glucose monitoring. After an introduction to electrochemical glucose biosensors, we highlight recent progress based on using advanced nanomaterials at the electrode-enzyme interface of three generations of glucose sensors. Subsequently, we cover recent activity and challenges towards next-generation wearable non-invasive glucose monitoring devices based on innovative sensing principles, alternative body fluids, advanced flexible materials, and novel platforms. This is followed by highlighting the latest progress in the field of minimally-invasive continuous glucose monitoring (CGM) which offers real-time information about interstitial glucose levels, by focusing on the challenges toward developing biocompatible membrane coatings to protect electrochemical glucose sensors against surface biofouling. Subsequent sections cover new analytical concepts of self-powered glucose sensors, paper-based glucose sensing and multiplexed detection of diabetes-related biomarkers. Finally, we will cover the latest advances in commercially available devices along with the upcoming future technologies.
Collapse
Affiliation(s)
- Hazhir Teymourian
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA.
| | | | | |
Collapse
|
14
|
Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions. Biosens Bioelectron 2020; 165:112331. [PMID: 32729477 DOI: 10.1016/j.bios.2020.112331] [Citation(s) in RCA: 131] [Impact Index Per Article: 26.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Accepted: 05/25/2020] [Indexed: 12/17/2022]
Abstract
Diabetes is a pathological condition that requires the continuous monitoring of glucose level in the blood. Its control has been tremendously improved by the application of point-of-care devices. Conventional enzyme-based sensors with electrochemical and optical transduction systems can successfully measure the glucose concentration in human blood, but they suffer from the low stability of the enzyme. Non-enzymatic wearable electrochemical and optical sensors, with low-cost, high stability, point-of-care testing and online monitoring of glucose levels in biological fluids, have recently been developed and can help to manage and control diabetes worldwide. Advances in nanoscience and nanotechnology have enabled the development of novel nanomaterials that can be implemented for the use in enzyme-free systems to detect glucose. This review summarizes recent developments of enzyme-free electrochemical and optical glucose sensors, as well as their respective wearable and commercially available devices, capable of detecting glucose at physiological pH conditions without the need to pretreat the biological fluids. Additionally, the evolution of electrochemical glucose sensor technology and a couple of widely used optical detection systems along with the glucose detection mechanism is also discussed. Finally, this review addresses limitations and challenges of current non-enzymatic electrochemical, optical, and wearable glucose sensor technologies and highlights opportunities for future research directions.
Collapse
|
15
|
Wu H, Yan Y, Huang Q, Liang G, Qiu F, Ye Z, Liu D. A simple, cost-effective and selective analysis of glucose via electrochemical impedance sensing based on copper and nitrogen co-doped carbon quantum dots. NEW J CHEM 2020. [DOI: 10.1039/d0nj01754j] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Cu,N co-doped CQDs were prepared and employed as electrode modification materials for improving the efficiency of electron transfer. The Cu and N co-doped CQDs exhibited high electrocatalytic activity for glucose sensing in alkaline medium.
Collapse
Affiliation(s)
- Haiyan Wu
- School of Environmental and Safety Engineering
- Jiangsu University
- Zhenjiang 212013
- China
- School of Chemical and Environmental Engineering
| | - Yu Yan
- School of Chemical and Environmental Engineering
- Jiangsu University of Technology
- Changzhou 213001
- China
| | - Qingshuang Huang
- School of Chemical and Environmental Engineering
- Jiangsu University of Technology
- Changzhou 213001
- China
| | - Guobin Liang
- School of Chemical and Environmental Engineering
- Jiangsu University of Technology
- Changzhou 213001
- China
| | - Fengxian Qiu
- School of Chemistry and Chemical Engineering
- Jiangsu University
- Zhenjiang 212013
- China
| | - Zhaolian Ye
- School of Chemical and Environmental Engineering
- Jiangsu University of Technology
- Changzhou 213001
- China
| | - Dan Liu
- School of Chemical and Environmental Engineering
- Jiangsu University of Technology
- Changzhou 213001
- China
| |
Collapse
|
16
|
Tomanin PP, Cherepanov PV, Besford QA, Christofferson AJ, Amodio A, McConville CF, Yarovsky I, Caruso F, Cavalieri F. Cobalt Phosphate Nanostructures for Non-Enzymatic Glucose Sensing at Physiological pH. ACS APPLIED MATERIALS & INTERFACES 2018; 10:42786-42795. [PMID: 30422616 DOI: 10.1021/acsami.8b12966] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Nanostructured materials have potential as platforms for analytical assays and catalytic reactions. Herein, we report the synthesis of electrocatalytically active cobalt phosphate nanostructures (CPNs) using a simple, low-cost, and scalable preparation method. The electrocatalytic properties of CPNs toward the electrooxidation of glucose (Glu) were studied by cyclic voltammetry and chronoamperometry in relevant biological electrolytes, such as phosphate-buffered saline (PBS), at physiological pH (7.4). Using CPNs, Glu detection could be achieved over a wide range of biologically relevant concentrations, from 1 to 30 mM Glu in PBS, with a sensitivity of 7.90 nA/mM cm2 and a limit of detection of 0.3 mM, thus fulfilling the necessary requirements for human blood Glu detection. In addition, CPNs showed a high structural and functional stability over time at physiological pH. The CPN-coated electrodes could also be used for Glu detection in the presence of interfering agents (e.g., ascorbic acid and dopamine) and in human serum. Density functional theory calculations were performed to evaluate the interaction of Glu with different faceted cobalt phosphate surfaces; the results revealed that specific surface presentations of under-coordinated cobalt led to the strongest interaction with Glu, suggesting that enhanced detection of Glu by CPNs can be achieved by lowering the surface coordination of cobalt. Our results highlight the potential use of phosphate-based nanostructures as catalysts for electrochemical sensing of biochemical analytes.
Collapse
Affiliation(s)
- Pietro Pacchin Tomanin
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, and the Department of Chemical Engineering , The University of Melbourne , Parkville , Victoria 3010 , Australia
| | - Pavel V Cherepanov
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, and the Department of Chemical Engineering , The University of Melbourne , Parkville , Victoria 3010 , Australia
| | - Quinn A Besford
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, and the Department of Chemical Engineering , The University of Melbourne , Parkville , Victoria 3010 , Australia
| | | | - Alessia Amodio
- Department of Chemical Science and Technologies , University of Rome Tor Vergata , via della ricerca scientifica 1 , 00133 Rome , Italy
| | | | | | - Frank Caruso
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, and the Department of Chemical Engineering , The University of Melbourne , Parkville , Victoria 3010 , Australia
| | - Francesca Cavalieri
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, and the Department of Chemical Engineering , The University of Melbourne , Parkville , Victoria 3010 , Australia
- Department of Chemical Science and Technologies , University of Rome Tor Vergata , via della ricerca scientifica 1 , 00133 Rome , Italy
| |
Collapse
|
17
|
Tashkhourian J, Nami-Ana SF, Shamsipur M. A new bifunctional nanostructure based on Two-Dimensional nanolayered of Co(OH)2 exfoliated graphitic carbon nitride as a high performance enzyme-less glucose sensor: Impedimetric and amperometric detection. Anal Chim Acta 2018; 1034:63-73. [DOI: 10.1016/j.aca.2018.06.052] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Revised: 06/09/2018] [Accepted: 06/15/2018] [Indexed: 10/28/2022]
|
18
|
Deng W, Dai R, You C, Hu P, Sun X, Xiong X, Huang K, Huo F. In Situ Formation of a 3D Amorphous Cobalt- Borate Nanoarray: An Efficient Non-Noble Metal Catalytic Electrode for Non-Enzyme Glucose Detection. ChemistrySelect 2018. [DOI: 10.1002/slct.201800646] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Wenqing Deng
- College of Chemistry and Materials Science; Sichuan Normal University; Chendu 610064, Sichuan China
- School of Chemical Engineering; Neijiang Normal University, Neijiang; Sichuan 610068, Sichuan China
| | - Rui Dai
- College of Chemistry and Materials Science; Sichuan Normal University; Chendu 610064, Sichuan China
| | - Chao You
- College of Chemistry and Materials Science; Sichuan Normal University; Chendu 610064, Sichuan China
| | - Pingyue Hu
- College of Chemistry and Materials Science; Sichuan Normal University; Chendu 610064, Sichuan China
| | - Xuping Sun
- Institute of Fundamental and Frontier Science; University of Electronic Science and Technology of China; Chendu 610054, Sichuan China
| | - Xiaoli Xiong
- College of Chemistry and Materials Science; Sichuan Normal University; Chendu 610064, Sichuan China
| | - Ke Huang
- College of Chemistry and Materials Science; Sichuan Normal University; Chendu 610064, Sichuan China
| | - Feng Huo
- School of Chemical Engineering; Neijiang Normal University, Neijiang; Sichuan 610068, Sichuan China
| |
Collapse
|
19
|
Raza W, Krupanidhi SB. Engineering Defects in Graphene Oxide for Selective Ammonia and Enzyme-Free Glucose Sensing and Excellent Catalytic Performance for para-Nitrophenol Reduction. ACS APPLIED MATERIALS & INTERFACES 2018; 10:25285-25294. [PMID: 30035528 DOI: 10.1021/acsami.8b05162] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Recently, extensive attention has been given to developing an active and durable metal-free economical sensor and catalyst. Graphene oxide (GO)-based sensors and catalysts have been considered as a promising candidate in current material science research. However, the sensing and catalytic properties of GO also need to be further improved to satisfy the specific applications, such as gas detection in harsh environments, medical diagnosis based on human breath, blood glucose detection, catalytic activity, and so forth. Therefore, the effect of nitrogen in GO on the performance of glucose and ammonia sensing, and catalytic activity has been investigated. Herein, we propose a practical, high-sensitive sensor and catalyst based on high-quality defect N-enriched GO. One-step, low-cost solvothermal synthesis of N-enriched GO has been exploited for the development of high-performance sensors and excellent catalyst at room temperature. The resultant N-enriched GO (N8GO) has been studied as a promising sensing material for ammonia, glucose, and para-nitrophenol (PNP) reduction. The prevalent outstanding sensing and catalytic performance may be due to the synergistic effect of nitrogen. A probable mechanism for sensing and catalytic reduction of PNP using N8GO has been proposed.
Collapse
Affiliation(s)
- Waseem Raza
- Materials Research Centre, Indian Institute of Science , Bangalore 560012 , India
| | - S B Krupanidhi
- Materials Research Centre, Indian Institute of Science , Bangalore 560012 , India
| |
Collapse
|
20
|
Recent advances in electrochemical non-enzymatic glucose sensors - A review. Anal Chim Acta 2018; 1033:1-34. [PMID: 30172314 DOI: 10.1016/j.aca.2018.05.051] [Citation(s) in RCA: 326] [Impact Index Per Article: 46.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 04/23/2018] [Accepted: 05/18/2018] [Indexed: 12/13/2022]
Abstract
This review encompasses the mechanisms of electrochemical glucose detection and recent advances in non-enzymatic glucose sensors based on a variety of materials ranging from platinum, gold, metal alloys/adatom, non-precious transition metal/metal oxides to glucose-specific organic materials. It shows that the discovery of new materials based on unique nanostructures have not only provided the detailed insight into non-enzymatic glucose oxidation, but also demonstrated the possibility of direct detection in whole blood or interstitial fluids. We critically evaluate various aspects of non-enzymatic electrochemical glucose sensors in terms of significance as well as performance. Beyond laboratory tests, the prospect of commercialization of non-enzymatic glucose sensors is discussed.
Collapse
|
21
|
Chinnadayyala SR, Park I, Cho S. Nonenzymatic determination of glucose at near neutral pH values based on the use of nafion and platinum black coated microneedle electrode array. Mikrochim Acta 2018; 185:250. [DOI: 10.1007/s00604-018-2770-1] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Accepted: 03/12/2018] [Indexed: 10/17/2022]
|
22
|
Foroughi F, Rahsepar M, Hadianfard MJ, Kim H. Microwave-assisted synthesis of graphene modified CuO nanoparticles for voltammetric enzyme-free sensing of glucose at biological pH values. Mikrochim Acta 2017; 185:57. [DOI: 10.1007/s00604-017-2558-8] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 11/09/2017] [Indexed: 02/07/2023]
|
23
|
Electrochemical nonenzymatic sensing of glucose using advanced nanomaterials. Mikrochim Acta 2017; 185:49. [PMID: 29594566 DOI: 10.1007/s00604-017-2609-1] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 12/02/2017] [Indexed: 12/22/2022]
Abstract
An overview (with 376 refs.) is given here on the current state of methods for electrochemical sensing of glucose based on the use of advanced nanomaterials. An introduction into the field covers aspects of enzyme based sensing versus nonenzymatic sensing using nanomaterials. The next chapter cover the most commonly used nanomaterials for use in such sensors, with sections on uses of noble metals, transition metals, metal oxides, metal hydroxides, and metal sulfides, on bimetallic nanoparticles and alloys, and on other composites. A further section treats electrodes based on the use of carbon nanomaterials (with subsections on carbon nanotubes, on graphene, graphene oxide and carbon dots, and on other carbonaceous nanomaterials. The mechanisms for electro-catalysis are also discussed, and several Tables are given where the performance of sensors is being compared. Finally, the review addresses merits and limitations (such as the frequent need for working in strongly etching alkaline solutions and the need for diluting samples because sensors often have analytical ranges that are far below the glucose levels found in blood). We also address market/technology gaps in comparison to commercially available enzymatic sensors. Graphical Abstract Schematic representation of electrochemical nonenzymatic glucose sensing on the nanomaterials modified electrodes. At an applied potential, the nanomaterial-modified electrodes exhibit excellent electrocatalytic activity for direct oxidation of glucose oxidation.
Collapse
|
24
|
Wen YH, Huang R, Shao GF, Sun SG. Thermal Stability of Co-Pt and Co-Au Core-Shell Structured Nanoparticles: Insights from Molecular Dynamics Simulations. J Phys Chem Lett 2017; 8:4273-4278. [PMID: 28837772 DOI: 10.1021/acs.jpclett.7b01880] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Co-Pt and Co-Au core-shell nanoparticles were heated by molecular dynamics simulations to investigate their thermal stability. Two core structures, that is, hcp Co and fcc Co, have been addressed. The results demonstrate that the hcp-fcc phase transition happens in the hcp-Co-core/fcc-Pt-shell nanoparticle, while it is absent in the hcp-Co-core/fcc-Au-shell one. The stacking faults appear in both Pt and Au shells despite different structures of the Co core. The Co core and Pt shell concurrently melt and present an identical melting point in both Co-Pt core-shell nanoparticles. However, typical two-stage melting occurs in both Co-Au core-shell nanoparticles. Furthermore, the Au shell in the hcp-Co-core/fcc-Au-shell nanoparticle exhibits a lower melting point than that in the fcc-Co-core/fcc-Au-shell one, while the melting points are closely equal for both hcp and fcc Co cores. All of these observations suggest that their thermal stability strongly depends on the structure of the core and the element of the shell.
Collapse
Affiliation(s)
- Yu-Hua Wen
- Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Physics, Xiamen University , Xiamen 361005, China
| | - Rao Huang
- Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Physics, Xiamen University , Xiamen 361005, China
| | - Gui-Fang Shao
- Department of Automation, Xiamen University , Xiamen 361005, China
| | - Shi-Gang Sun
- State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, Xiamen University , Xiamen 361005, China
| |
Collapse
|
25
|
Amperometric nonenzymatic determination of glucose via a glassy carbon electrode modified with nickel hydroxide and N-doped reduced graphene oxide. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2332-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
26
|
Zhang L, Ding Y, Li R, Ye C, Zhao G, Wang Y. Electrodeposition of ultra-long copper nanowires on a titanium foil electrode for nonenzymatic voltammetric sensing of glucose. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2279-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
27
|
Leonardi SG, Marini S, Espro C, Bonavita A, Galvagno S, Neri G. In-situ grown flower-like nanostructured CuO on screen printed carbon electrodes for non-enzymatic amperometric sensing of glucose. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2232-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
28
|
Hydrothermal deposition of CuO/rGO/Cu2O nanocomposite on copper foil for sensitive nonenzymatic voltammetric determination of glucose and hydrogen peroxide. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2229-9] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
29
|
A glassy carbon electrode modified with ordered nanoporous Co3O4 for non-enzymatic sensing of glucose. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2079-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
30
|
Witkowska Nery E, Kundys M, Jeleń PS, Jönsson-Niedziółka M. Electrochemical Glucose Sensing: Is There Still Room for Improvement? Anal Chem 2016; 88:11271-11282. [DOI: 10.1021/acs.analchem.6b03151] [Citation(s) in RCA: 160] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Emilia Witkowska Nery
- Institute
of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Magdalena Kundys
- Institute
of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Paulina S. Jeleń
- Institute
of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | | |
Collapse
|
31
|
Heterostructured palladium-platinum core-shell nanocubes for use in a nonenzymatic amperometric glucose sensor. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1976-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
32
|
Min H, Wu W, Wu H, Wang S, Feng C, Ding Y. Synthesis of PtxSn/MWCNTs and their Application in Non-enzymatic Glucose and Hydrogen Peroxide Sensors. ELECTROANAL 2016. [DOI: 10.1002/elan.201600530] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Affiliation(s)
- Hui Min
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Ministry of Education & College of Chemistry & Chemical Engineering; Hubei University; Wuhan 430062 PR China
| | - Wenqin Wu
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Ministry of Education & College of Chemistry & Chemical Engineering; Hubei University; Wuhan 430062 PR China
| | - Huimin Wu
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Ministry of Education & College of Chemistry & Chemical Engineering; Hubei University; Wuhan 430062 PR China
| | - Shengfu Wang
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Ministry of Education & College of Chemistry & Chemical Engineering; Hubei University; Wuhan 430062 PR China
| | - Chuanqi Feng
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials & Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Ministry of Education & College of Chemistry & Chemical Engineering; Hubei University; Wuhan 430062 PR China
| | - Yu Ding
- College of Chemistry and Materials Science; Hubei Engineering University; Xiaogan 432000 China
| |
Collapse
|
33
|
Zhao A, Zhang Z, Zhang P, Xiao S, Wang L, Dong Y, Yuan H, Li P, Sun Y, Jiang X, Xiao F. 3D nanoporous gold scaffold supported on graphene paper: Freestanding and flexible electrode with high loading of ultrafine PtCo alloy nanoparticles for electrochemical glucose sensing. Anal Chim Acta 2016; 938:63-71. [PMID: 27619087 DOI: 10.1016/j.aca.2016.08.013] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2016] [Revised: 07/28/2016] [Accepted: 08/09/2016] [Indexed: 11/25/2022]
Abstract
Recent advances in on-body wearable medical apparatus and implantable devices drive the development of light-weight and bendable electrochemical sensors, which require the design of high-performance flexible electrode system. In this work, we reported a new type of freestanding and flexible electrode based on graphene paper (GP) supported 3D monolithic nanoporous gold (NPG) scaffold (NPG/GP), which was further modified by a layer of highly dense, well dispersed and ultrafine binary PtCo alloy nanoparticles via a facile and effective ultrasonic electrodeposition method. Our results demonstrated that benefited from the synergistic effect of the electrocatalytically active PtCo alloy nanoparticles, the large-active-area and highly conductive 3D NPG scaffold, and the mechanically strong and stable GP electrode substrate, the resultant PtCo alloy nanoparticles modified NPG/GP (PtCo/NPG/GP) exhibited high mechanical strength and good electrochemical sensing performances toward nonenzymatic detection of glucose, including a wide linear range from 35 μM- to 30 mM, a low detection limit of 5 μM (S/N = 3) and a high sensitivity of 7.84 μA cm(-2) mM(-1) as well as good selectivity, long-term stability and reproducibility. The practical application of the proposed PtCo/NPG/GP has also been demonstrated in in vitro detection of blood glucose in real clinic samples.
Collapse
Affiliation(s)
- Anshun Zhao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Zhaowei Zhang
- Key Laboratory of Detection of Mycotoxins, Ministry of Agriculture, Oil Crops Research Institute of Chinese Academy of Agricultural Sciences, Wuhan 430062, China
| | - Penghui Zhang
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Shuang Xiao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Lu Wang
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Yue Dong
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Hao Yuan
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Peiwu Li
- Key Laboratory of Detection of Mycotoxins, Ministry of Agriculture, Oil Crops Research Institute of Chinese Academy of Agricultural Sciences, Wuhan 430062, China
| | - Yimin Sun
- Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430073, China
| | - Xueliang Jiang
- Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430073, China
| | - Fei Xiao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China.
| |
Collapse
|
34
|
Enhanced Non-enzymatic amperometric sensing of glucose using Co(OH)2 nanorods deposited on a three dimensional graphene network as an electrode material. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1890-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
35
|
|
36
|
Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1862-z] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
37
|
Direct electrodeposition of highly ordered gold nanotube arrays for use in non-enzymatic amperometric sensing of glucose. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1835-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
38
|
Li SJ, Hou LL, Yuan BQ, Chang MZ, Ma Y, Du JM. Enzyme-free glucose sensor using a glassy carbon electrode modified with reduced graphene oxide decorated with mixed copper and cobalt oxides. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1817-4] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
39
|
Non-enzymatic sensing of glucose using a glassy carbon electrode modified with gold nanoparticles coated with polyethyleneimine and 3-aminophenylboronic acid. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1782-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
40
|
Nayak P, Nair SP, Ramaprabhu S. Enzyme-less and low-potential sensing of glucose using a glassy carbon electrode modified with palladium nanoparticles deposited on graphene-wrapped carbon nanotubes. Mikrochim Acta 2015. [DOI: 10.1007/s00604-015-1729-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|