1
|
Sharma KP, Shin M, Awasthi GP, Cho S, Yu C. One-step hydrothermal synthesis of CuS/MoS 2 composite for use as an electrochemical non-enzymatic glucose sensor. Heliyon 2024; 10:e23721. [PMID: 38312675 PMCID: PMC10835264 DOI: 10.1016/j.heliyon.2023.e23721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 12/10/2023] [Accepted: 12/12/2023] [Indexed: 02/06/2024] Open
Abstract
Early diagnosis may be crucial for the prevention of chronic diabetes mellitus. For that herein, we prepared a CuS/MoS2 composite for a non-enzymatic glucose sensor through a one-step hydrothermal method owing to the synergetic effect of CuS/MoS2. The surface morphology of CuS/MoS2 was studied by Field Emission Scanning Electron Microscopy (FESEM) and Cs-corrected Scanning Transmission Electron Microscopy (Cs-STEM). The crystallinity and surface composition of CuS/MoS2 were analyzed by X-ray Diffraction (XRD) and X-ray Photoelectron Spectroscopy (XPS) respectively. The working electrode was prepared from CuS/MoS2 electrocatalyst, and for that dispersed solution of electrocatalyst was used to fabricate the material-loaded glassy carbon electrode (GC). CuS/MoS2 composite shows the viability of electrocatalyst to oxidize glucose in an alkaline solution with sensitivity and detection limit of 252.71 μA mM-1 cm-2 and 1.52 μM respectively. The proposed glucose sensor showed reasonable stability and potential selectivity during electrochemical analysis. Accordingly, the CuS/MoS2 composite has potential as a viable material for glucose sensing in diluted human serum.
Collapse
Affiliation(s)
- Krishna Prasad Sharma
- Department of Energy Storage/Conversion Engineering (BK21 FOUR), Jeonbuk National University, Jeonju, Jeollabuk-do, 54896, Republic of Korea
| | - Miyeon Shin
- Department of Energy Storage/Conversion Engineering (BK21 FOUR), Jeonbuk National University, Jeonju, Jeollabuk-do, 54896, Republic of Korea
| | - Ganesh Prasad Awasthi
- Division of Convergence Technology Engineering, Jeonbuk National University, Jeonju, Jeollabuk-do, 54896, Republic of Korea
| | - Soonhwan Cho
- ENPLUS Co., LTD, 167 Jayumuyeok-gil, Baeksan-myeon, Gimje-si, 54352, Republic of Korea
| | - Changho Yu
- Department of Energy Storage/Conversion Engineering (BK21 FOUR), Jeonbuk National University, Jeonju, Jeollabuk-do, 54896, Republic of Korea
- Division of Convergence Technology Engineering, Jeonbuk National University, Jeonju, Jeollabuk-do, 54896, Republic of Korea
| |
Collapse
|
2
|
Tailored design of Ni(OH)2 nanocages internally decorated with CuS nanocages to mutually ameliorate electrocatalytic dynamics for highly sensitive glucose detection. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115893] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
3
|
Mazurków JM, Kusior A, Radecka M. Electrochemical Characterization of Modified Glassy Carbon Electrodes for Non-Enzymatic Glucose Sensors. SENSORS 2021; 21:s21237928. [PMID: 34883931 PMCID: PMC8659783 DOI: 10.3390/s21237928] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 11/17/2021] [Accepted: 11/24/2021] [Indexed: 01/07/2023]
Abstract
The diversity of materials proposed for non-enzymatic glucose detection and the lack of standardized protocols for assessing sensor performance have caused considerable confusion in the field. Therefore, methods for pre-evaluation of working electrodes, which will enable their conscious design, are currently intensively sought. Our approach involved comprehensive morphologic and structural characterization of copper sulfides as well as drop-casted suspensions based on three different polymers-cationic chitosan, anionic Nafion, and nonionic polyvinylpyrrolidone (PVP). For this purpose, scanning electron microscopy (SEM), X-ray diffraction (XRD), and Raman spectroscopy were applied. Subsequently, comparative studies of electrochemical properties of bare glassy carbon electrode (GCE), polymer- and copper sulfides/polymer-modified GCEs were performed using electrochemical impedance spectroscopy (EIS) and voltammetry. The results from EIS provided an explanation for the enhanced analytical performance of Cu-PVP/GCE over chitosan- and Nafion-based electrodes. Moreover, it was found that the pH of the electrolyte significantly affects the electrocatalytic behavior of copper sulfides, indicating the importance of OHads in the detection mechanism. Additionally, diffusion was denoted as a limiting step in the irreversible electrooxidation process that occurs in the proposed system.
Collapse
|
4
|
Sarkhosh-Inanlou R, Shafiei-Irannejad V, Azizi S, Jouyban A, Ezzati-Nazhad Dolatabadi J, Mobed A, Adel B, Soleymani J, Hamblin MR. Applications of scaffold-based advanced materials in biomedical sensing. Trends Analyt Chem 2021; 143:116342. [PMID: 34602681 PMCID: PMC8474058 DOI: 10.1016/j.trac.2021.116342] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
There have been many efforts to synthesize advanced materials that are capable of real-time specific recognition of a molecular target, and allow the quantification of a variety of biomolecules. Scaffold materials have a porous structure, with a high surface area and their intrinsic nanocavities can accommodate cells and macromolecules. The three-dimensional structure (3D) of scaffolds serves not only as a fibrous structure for cell adhesion and growth in tissue engineering, but can also provide the controlled release of drugs and other molecules for biomedical applications. There has been a limited number of reports on the use of scaffold materials in biomedical sensing applications. This review highlights the potential of scaffold materials in the improvement of sensing platforms and summarizes the progress in the application of novel scaffold-based materials as sensor, and discusses their advantages and limitations. Furthermore, the influence of the scaffold materials on the monitoring of infectious diseases such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and bacterial infections, was reviewed.
Collapse
Affiliation(s)
- Roya Sarkhosh-Inanlou
- Cellular and Molecular Research Center, Cellular and Molecular Medicine Institute, Urmia University of Medical Sciences, Urmia, Iran
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Vahid Shafiei-Irannejad
- Cellular and Molecular Research Center, Cellular and Molecular Medicine Institute, Urmia University of Medical Sciences, Urmia, Iran
| | - Sajjad Azizi
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Ahmad Mobed
- Aging Research Institute, Faculty of Medicine, Tabriz University of Medical Sciences, Iran
| | - Bashir Adel
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Liver and Gastrointestinal Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Jafar Soleymani
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Michael R Hamblin
- Laser Research Centre, Faculty of Health Science, University of Johannesburg, Doornfontein, Johannesburg, 2028, South Africa
| |
Collapse
|
5
|
Venkadesh A, Mathiyarasu J, Dave S, Radhakrishnan S. Amine mediated synthesis of nickel oxide nanoparticles and their superior electrochemical sensing performance for glucose detection. INORG CHEM COMMUN 2021. [DOI: 10.1016/j.inoche.2021.108779] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
6
|
Settu K, Chiu PT, Huang YM. Laser-Induced Graphene-Based Enzymatic Biosensor for Glucose Detection. Polymers (Basel) 2021; 13:2795. [PMID: 34451332 PMCID: PMC8400493 DOI: 10.3390/polym13162795] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/13/2021] [Accepted: 08/17/2021] [Indexed: 02/03/2023] Open
Abstract
Laser-induced graphene (LIG) has recently been receiving increasing attention due to its simple fabrication and low cost. This study reports a flexible laser-induced graphene-based electrochemical biosensor fabricated on a polymer substrate by the laser direct engraving process. For this purpose, a 450 nm UV laser was employed to produce a laser-induced graphene electrode (LIGE) on a polyimide substrate. After the laser engraving of LIGE, the chitosan-glucose oxidase (GOx) composite was immobilized on the LIGE surface to develop the biosensor for glucose detection. It was observed that the developed LIGE biosensor exhibited good amperometric responses toward glucose detection over a wide linear range up to 8 mM. The GOx/chitosan-modified LIGE biosensor showed high sensitivity of 43.15 µA mM-1 cm-2 with a detection limit of 0.431 mM. The interference studies performed with some possible interfering compounds such as ascorbic acid, uric acid, and urea exhibited no interference as there was no difference observed in the amperometric glucose detection. It was suggested that the LIGE-based biosensor proposed herein was easy to prepare and could be used for low-cost, rapid, and sensitive/selective glucose detection.
Collapse
Affiliation(s)
- Kalpana Settu
- Department of Electrical Engineering, National Taipei University, New Taipei City 23741, Taiwan; (P.-T.C.); (Y.-M.H.)
| | | | | |
Collapse
|
7
|
Zhang X, Cao Q, Guo Z, Zhang M, Zhou M, Zhai Z, Xu Y. Self-assembly of MoS2 nanosheet on functionalized pomelo peel derived carbon and its electrochemical sensor behavior toward taxifolin. INORG CHEM COMMUN 2021. [DOI: 10.1016/j.inoche.2021.108631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
8
|
Chen L, Xie W, Luo Y, Ding X, Fu B, Gopinath SCB, Xiong Y. Sensitive silica-alumina modified capacitive non-Faradaic glucose sensor for gestational diabetes. Biotechnol Appl Biochem 2021; 69:840-847. [PMID: 33786878 DOI: 10.1002/bab.2155] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 03/23/2021] [Indexed: 01/01/2023]
Abstract
A highly sensitive silica-alumina (Si-Al)-modified capacitive non-Faradaic glucose biosensor was introduced to monitor gestational diabetes. Glucose oxidase (GOx) was attached to the Si-Al electrode surface as the probe through amine-modification followed by glutaraldehyde premixed GOx as aldehyde-amine chemistry. This Si-Al (∼50 nm) modified electrode surface has increased the current flow upon binding of GOx with glucose. Capacitance values were increased by increasing the glucose concentrations. A mean capacitance value was plotted and the detection limit was found as 0.03 mg/mL with the regression coefficient value, R² = 0.9782 [y = 0.8391x + 1.338] on the linear range between 0.03 and 1 mg/mL. Further, a biofouling experiment with fructose and galactose did not increase the capacitance, indicating the specific glucose detection. This Si-Al-modified capacitance sensor detects a lower level of glucose presence and helps in monitoring gestational diabetes.
Collapse
Affiliation(s)
- Lizhen Chen
- Department of Obstetrics and Gynecology, Jingdezhen First People's Hospital, Jingdezhen, Jiangxi Province, China
| | - Wenyang Xie
- Department of Gynecological Oncology, Jiujiang Maternal and Child Health Hospital, Jiujiang, Jiangxi Province, China
| | - Yao Luo
- Nanchang University, Nanchang City, Jiangxi Province, China
| | - Xiaolan Ding
- Department of Gynecology of Traditional Chinese Medicine, Binzhou Hospital of Traditional Chinese Medicine, Binzhou, Shandong, China
| | - Bing Fu
- Nanchang University, Nanchang City, Jiangxi Province, China
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, 01000, Malaysia.,Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis (UniMAP), Arau, Perlis, 02600, Malaysia
| | - Yuanhuan Xiong
- Department of Gynecology, Jiangxi Provincial People's Hospital, Nanchang, Jiangxi Province, China
| |
Collapse
|
9
|
Ahmad MW, Verma S, Yang DJ, Islam MU, Choudhury A. Synthesis of silver nanoparticles-decorated poly(m-aminophenol) nanofibers and their application in a non-enzymatic glucose biosensor. JOURNAL OF MACROMOLECULAR SCIENCE PART A-PURE AND APPLIED CHEMISTRY 2021. [DOI: 10.1080/10601325.2021.1886585] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Md. Wasi Ahmad
- Department of Chemical Engineering, College of Engineering, Dhofar University, Salalah, Sultanate of Oman
| | - Sushil Verma
- Department of Chemical Engineering, Birla Institute of Technology, Ranchi, India
| | - Duck-Joo Yang
- Department of Chemistry and the Alan G. MacDiarmid NanoTech Institute, The University of Texas at Dallas, Richardson, Texas, USA
| | - Mazhar Ul Islam
- Department of Chemical Engineering, College of Engineering, Dhofar University, Salalah, Sultanate of Oman
| | - Arup Choudhury
- Department of Chemical Engineering, Birla Institute of Technology, Ranchi, India
| |
Collapse
|
10
|
Khazraei A, Tarlani A, Eslami-Moghadam M, Muzart J. New Bi 2MoO 6 nano-shapes toward ultrasensitive enzymeless glucose tracing: Synergetic effect of the Bi-Mo association. Talanta 2021; 221:121560. [PMID: 33076113 DOI: 10.1016/j.talanta.2020.121560] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/09/2020] [Accepted: 08/10/2020] [Indexed: 10/23/2022]
Abstract
In a novel approach, an efficient non-enzymatic glucose sensor based on pure phase of aurivillius bismuth molybdate (BM or γ-Bi2MoO6) mixed metal oxides is reported. Three BM samples were synthesized, with/without l-cysteine (Cys) and dodecylamine (DDA) as additives, leading to different shapes: bullet (BM-C), confetti (BM-2Cys) and candy (BM-2DDA). The morphology and purity of the structures were confirmed by FE-SEM images and XRD. In order to investigate the sensor application, the samples were integrated on reduced graphene oxide and incorporated into simple and inexpensive glassy carbon electrode (GCE) without using any polyvinylpyrrolidone (PVP) or Nafion. To perform cyclic voltammetry experiments, all three biosensors were measured in PBS solution (pH = 7) in ±1.5 voltage range and 50 mV s-1 scan rate. Glucose identification by the synthesized composites is an obvious sign of their high efficiency. According to chronoamperomograms, the best sensitivity of 3050 μA L mmol-1 cm-2 with linear range of 0.02-0.14 mmol L-1, low detection limit (LOD) of 0.004 mmol L-1 and the signal/noise equal to 3 was achieved by BM-2DDA/rGO/GCE biosensor and its speedy amperometric response is less than 5 s. This biosensor showed impressive selectivity, repeatability and reproducibility results besides it maintains its stability considerably in great percentage of 98.5% after eight weeks. Also it showed prolonged stability after 50 min.
Collapse
Affiliation(s)
- Avideh Khazraei
- Chemistry & Chemical Engineering Research Center of Iran, Pajoohesh Blvd., Km 17, Karaj Hwy, Tehran, 14968-13151, Iran
| | - Aliakbar Tarlani
- Chemistry & Chemical Engineering Research Center of Iran, Pajoohesh Blvd., Km 17, Karaj Hwy, Tehran, 14968-13151, Iran.
| | - Mahboube Eslami-Moghadam
- Chemistry & Chemical Engineering Research Center of Iran, Pajoohesh Blvd., Km 17, Karaj Hwy, Tehran, 14968-13151, Iran
| | - Jacques Muzart
- Institut de Chimie Moléculaire de Reims, CNRS-Université de Reims Champagne-Ardenne, BP 1039, 51687, Reims Cedex 2, France
| |
Collapse
|
11
|
Xu F, Wu M, Ma G, Xu H, Shang W. Copper-molybdenum sulfide/reduced graphene oxide hybrid with three-dimensional wrinkles and pores for enhanced amperometric detection of glucose. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105432] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
12
|
Lynch PJ, Amorim Graf A, Ogilvie SP, Large MJ, Salvage JP, Dalton AB. Surfactant-free liquid-exfoliated copper hydroxide nanocuboids for non-enzymatic electrochemical glucose detection. J Mater Chem B 2020; 8:7733-7739. [PMID: 32725027 DOI: 10.1039/d0tb01476a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
To facilitate printable sensing solutions particles need to be suspended and stabilised in a liquid medium. Hansen parameters were used to identify that alcohol-water blends are ideal for stabilising colloidal copper hydroxide in dispersion. The suspended material can be further separated in various size fractions with a distinct cuboid geometry which was verified using atomic force microscopy. This facilitates the development of Raman spectroscopic metrics for determining particle sizes. This aspect ratio is related to the anisotropic crystal structure of the bulk crystallites. As the size of the nanocuboids decreases electrochemical sensitivity of the material increases due to an increase in specific surface area. Electrochemical glucose sensitivity was investigated using both cyclic voltammetry and chronoamperometry. The sensitivity is noted to saturate with film thickness. The electrochemical response of 253 mA M-1 cm-2 up to 0.1 mM and 120 mA cm-2 up to 0.6 mM allow for calibration of potential devices. These results indicate suitability for use as a glucose sensor and, due to the surfactant-free, low boiling point solvent approach used to exfoliate the nanocuboids, it is an ideal candidate for printable solutions. The ease of processing will also allow this material to be integrated in composite films for improved functionality in future devices.
Collapse
Affiliation(s)
- Peter J Lynch
- University of Sussex, Department of Physics and Astronomy, Brighton, BN1 9RH, UK.
| | | | | | | | | | | |
Collapse
|
13
|
Rajaram R, Kiruba M, Suresh C, Mathiyarasu J, Kumaran S, Kumaresan R. Amperometric determination of Myo-inositol using a glassy carbon electrode modified with nanostructured copper sulfide. Mikrochim Acta 2020; 187:334. [PMID: 32417978 DOI: 10.1007/s00604-020-04300-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Accepted: 04/23/2020] [Indexed: 12/30/2022]
Abstract
A method for the amperometric determination of Myo-inositol is presented. Nanostructured copper sulfide material was synthesized by solvothermal method and utilized as sensor matrix. The physico-chemical analysis using XRD, Raman, FE-SEM, TEM, and XPS confirmed the formation of CuS material. The voltammetric response of CuS-modified glassy carbon electrode for a successive Myo-inositol (0.5 μM) addition confirmed that the reaction takes place at the surface of the electrode. The modified electrode resulted in signal enhancement for a linear response ranging from 0.5-8.5 μM at an applied overpotential of 0.65 V with a correlation coefficient value (R2) of 0.99. The sensitivity and limit of detection of the modified electrode were 7.87 μA μM-1 cm-2 and 0.24 μM, respectively. The interfering effect of various compounds present in real samples was examined. Graphical abstract Schematic representation of synthetic protocol of nanostructured CuS and Myo-inositol oxidation on CuS-modified glassy carbon electrode in basic medium.
Collapse
Affiliation(s)
- Rajendran Rajaram
- Academy of Scientific and Innovative Research (AcSIR), CSIR - Central Electrochemical Research Institute (CECRI) Campus, Chennai, 600113, India.,Electrodics and Electrocatalysis Division, CSIR- Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, 630 003, India
| | - Muniyandi Kiruba
- PG & Research Department of Chemistry, Alagappa Government Arts College, Karaikudi, Tamil Nadu, 630003, India
| | - Chinnathambi Suresh
- Electrodics and Electrocatalysis Division, CSIR- Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, 630 003, India.
| | - Jayaraman Mathiyarasu
- Academy of Scientific and Innovative Research (AcSIR), CSIR - Central Electrochemical Research Institute (CECRI) Campus, Chennai, 600113, India. .,Electrodics and Electrocatalysis Division, CSIR- Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, 630 003, India.
| | - Shanmugam Kumaran
- Department of Bio-Technology, Periyar Maniammai Institute of Science & Technology, Periyar Nagar, Vallam, Thanjavur, Tamil Nadu, 613 403, India
| | - Ramanathan Kumaresan
- Department of Medical Biochemistry, Biomedical Division, School of Medicine, College of Health Sciences, Mekelle University (Ayder Campus), P.O. Box 1871, Mekelle, Ethiopia
| |
Collapse
|
14
|
Zhao R, Wang Y, Zhang Z, Hasebe Y, Tao D. A Glassy Carbon Electrode Modified with Molybdenite and Ag Nanoparticle Composite for Selectively Sensing of Ascorbic Acid. ANAL SCI 2019; 35:733-738. [PMID: 30745508 DOI: 10.2116/analsci.19p012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Molybdenite (MLN) was physically co-adsorbed with Ag nanoparticles (Ag) on a glassy carbon electrode (GCE) for selectively sensing of ascorbic acid (AA). The composite was characterized with a scan electron microscope, a high-temperature confocal laser scanning microscope, an X-ray diffractometer, an X-ray fluorescence analyzer and electrochemical methods. The prepared MLN/Ag-GCE sensor exhibited good properties including a linear range from 3.0 × 10-5 to 1.0 × 10-3 M toward AA, a low detection limit of 1.5 × 10-5 M, good selectivity, excellent reproducibility, and good stability. The synergistic effect between MLN and Ag nanoparticles results in an enhancement of the electrocatalytic activity for molybdenite.
Collapse
Affiliation(s)
- Rui Zhao
- School of Chemical Engineering, University of Science and Technology LiaoNing
| | - Yue Wang
- School of Chemical Engineering, University of Science and Technology LiaoNing
| | - Zhiqiang Zhang
- School of Chemical Engineering, University of Science and Technology LiaoNing
| | - Yasushi Hasebe
- Department of Life Science and Green Chemistry, Faculty of Engineering, Saitama Institute of Technology
| | - Dongping Tao
- School of Mineral Engineering, University of Science and Technology LiaoNing
| |
Collapse
|
15
|
Vilian ATE, Dinesh B, Kang SM, Krishnan UM, Huh YS, Han YK. Recent advances in molybdenum disulfide-based electrode materials for electroanalytical applications. Mikrochim Acta 2019; 186:203. [PMID: 30796594 DOI: 10.1007/s00604-019-3287-y] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 01/29/2019] [Indexed: 01/08/2023]
Abstract
The primary objective of this review article is to summarize the development and structural diversity of 2D/3D molybdenum disulfide (MoS2) based modified electrodes for electrochemical sensors and biosensor applications. Hydrothermal, mechanical, and ultrasonic techniques and solution-based exfoliation have been used to synthesize graphene-like 2D MoS2 layers. The unique physicochemical properties of MoS2 and its nanocomposites, including high mechanical strength, high carrier transport, large surface area, excellent electrical conductivity, and rapid electron transport rate, render them useful as efficient transducers in various electrochemical applications. The present review summarizes 2D/3D MoS2-based nanomaterials as an electrochemical platform for the detection and analysis of various biomolecules (e.g., neurotransmitters, NADH, glucose, antibiotics, DNA, proteins, and bacteria) and hazardous chemicals (e.g., heavy metal ions, organic compounds, and pesticides). The substantial improvements that have been achieved in the performance of enzyme-based amperometry, chemiluminescence, and nucleic acid sensors incorporating MoS2-based chemically modified electrodes are also addressed. We also summarize key sensor parameters such as limits of detection (LODs), sensitivity, selectivity, response time, and durability, as well as real applications of the sensing systems in the environmental, pharmaceutical, chemical, industrial, and food analysis fields. Finally, the remaining challenges in designing MoS2 nanostructures suitable for electroanalytical applications are outlined. Graphical abstract • MoS2 based materials exhibit high conductivity and improved electrochemical performance with great potential as a sensing electrode. • The role of MoS2 nanocomposite films and their detection strategies were reviewed. • Biomarkers detection for disease identification and respective clinical treatments were discussed. • Future Challenges, as well as possible research development for "MoS2 nanocomposites", are suggested.
Collapse
Affiliation(s)
- A T Ezhil Vilian
- Department of Energy and Materials Engineering, Dongguk University-Seoul, Seoul, 04620, Republic of Korea
| | - Bose Dinesh
- Center for Nanotechnology & Advanced Biomaterials (CeNTAB), School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, 613 401, India
| | - Sung-Min Kang
- Department of Biological Engineering, Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, Republic of Korea
| | - Uma Maheswari Krishnan
- Center for Nanotechnology & Advanced Biomaterials (CeNTAB), School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, 613 401, India.
| | - Yun Suk Huh
- Department of Biological Engineering, Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, Republic of Korea.
| | - Young-Kyu Han
- Department of Energy and Materials Engineering, Dongguk University-Seoul, Seoul, 04620, Republic of Korea.
| |
Collapse
|
16
|
Vladislavić N, Rončević IŠ, Buljac M, Brinić S, Krivić D, Buzuk M. Electroanalytical Determination of Cysteine Using the Electrodes Based on Ternary Silver-Copper Sulfides. SENSORS (BASEL, SWITZERLAND) 2018; 18:E3753. [PMID: 30400261 PMCID: PMC6263894 DOI: 10.3390/s18113753] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Revised: 10/29/2018] [Accepted: 10/31/2018] [Indexed: 01/08/2023]
Abstract
The amperometric determination of cysteine, using an electrode based on ternary silver-copper sulfide, is presented. Electrochemical characterizations (using cyclic voltammetry) of three electrode materials revealed that the electrode based on the material that consists of jalpaite (Ag₃CuS₂), doped with a small amount of metallic silver, has the best electrocatalytical performance for cysteine oxidation. For the amperometric determination, 0.142 V at pH 5 and 0.04 V at pH 7 vs. Ag/AgCl, related to the electrocatalytical oxidation of thiol group, were chosen. Electrochemical impedance spectroscopy together with Fourier transform infrared spectroscopy (FTIR) revealed that oxidation takes place on the electrode surface with fouling effect, which does not affect a wide linear working range between 1 μM and 100 μM. Sensitivities, at pH 5 and pH 7, are calculated to be 0.11 μA μM-1 and 0.10 μA μM-1, respectively. The detection limits were determined to be 0.036 μM and 0.024 μM for pH 5 and pH 7, respectively. In the presence of uric acid, folic acid, ascorbic acid, and glucose no interference was noticed. This electrode showed remarkable stability and excellent reproducibility. The electrode was exploited for the determination of cysteine in a dietary supplement with the excellent recoveries.
Collapse
Affiliation(s)
- Nives Vladislavić
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
| | - Ivana Škugor Rončević
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
| | - Maša Buljac
- Department of Environmental Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
| | - Slobodan Brinić
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
| | - Denis Krivić
- Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
| | - Marijo Buzuk
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
| |
Collapse
|
17
|
Luo J, Zhao D, Yang M, Qu F. Porous Ni 3N nanosheet array as a catalyst for nonenzymatic amperometric determination of glucose. Mikrochim Acta 2018; 185:229. [PMID: 29594805 DOI: 10.1007/s00604-018-2764-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Accepted: 03/06/2018] [Indexed: 01/09/2023]
Abstract
A glassy carbon electrode was modified with an array of porous Ni3N nanosheets (Ni3N NA) and studied for its use in non-enzymatic electrochemical detection of glucose. The morphology and structure of the Ni3N NA were characterized by scanning electron microscopy and X-ray diffraction. Electrochemical studies demonstrated that the Ni3N NA acts as an efficient catalyst for the electro-oxidation of glucose at pH 13, best at a working voltage of 0.55 V (vs. Ag/AgCl). Figures of merit include (a) high sensitivity (39 μA·mM-1·cm-2), (b) a low limit of detection (0.48 μM), and (c) a linear range that extends from 2 μM to 7.5 mM. The sensor was applied to the determination of glucose levels in human serum, and satisfactory results were obtained. Graphical abstract Nonenzymatic electrochemical glucose sensor based on porous Ni3N nanosheet array. The arrow indicates the successive addition of glucose standard solutions.
Collapse
Affiliation(s)
- Junjun Luo
- College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
| | - Dan Zhao
- College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
| | - Minghui Yang
- College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China.
| | - Fengli Qu
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong, 273165, China.
| |
Collapse
|
18
|
Gong H, Zheng F, Xu J, Sun C, Gao L, Hu P, Li Y, Gong Y, Zhen Q, Bashir S. Preparation and supercapacitive property of molybdenum disulfide (MoS2) nanoflake arrays- tungsten trioxide (WO3) nanorod arrays composite heterojunction: A synergistic effect of one-dimensional and two-dimensional nanomaterials. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.01.072] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
19
|
Li W, Qi H, Wang B, Wang Q, Wei S, Zhang X, Wang Y, Zhang L, Cui X. Ultrathin NiCo 2O 4 nanowalls supported on a 3D nanoporous gold coated needle for non-enzymatic amperometric sensing of glucose. Mikrochim Acta 2018; 185:124. [PMID: 29594748 DOI: 10.1007/s00604-017-2663-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Accepted: 12/31/2017] [Indexed: 11/29/2022]
Abstract
A disposable needle-type of hybrid electrode was prepared from a core of stainless steel needle whose surface was modified with a 3D nanoporous gold/NiCo2O4 nanowall hybrid structure for electrochemical non-enzymatic glucose detection. This hybrid electrode, best operated at 0.45 V (vs. SCE) in solutions of pH 13 has a linear response in the 0.01 to 21 mM glucose concentration range, a response time of <1 s, and a 1 μM detection limit (at an S/N ratio of 3). The remarkable enhancement compared to the solid gold/NiCo2O4 and stainless steel/NiCo2O4 hybrid electrodes in electrochemical performance is assumed to originate from the good electrical conductivity and large surface area of the hybrid electrode, which enhance the transport of mass and charge during electrochemical reactions. This biosensor was also applied to real sample analysis with little interferences. The electrode is disposable and considered to be a promising tool for non-enzymatic sensing of glucose in a variety of practical situations. Graphical abstract Ultrathin NiCo2O4 nanowalls supported on nanoporous gold that is coated on a stainless steel needle was fabricated for sensitive non-enzymatic amperometric sensing of glucose.
Collapse
Affiliation(s)
- Weiwei Li
- State Key Laboratory of Automotive Simulation and Control, Department of Materials Science, Jilin University, Changchun, 130012, China
| | - Hui Qi
- The Second Hospital of Jilin University, Changchun, 130041, People's Republic of China
| | - Baogang Wang
- The First Hospital of Jilin University, Changchun, 130041, People's Republic of China
| | - Qiyu Wang
- Key Laboratory for Renewable Energy, Institute of Physics, Chinese Academy of Sciences, Beijing, 100190, China
| | - Shuting Wei
- State Key Laboratory of Automotive Simulation and Control, Department of Materials Science, Jilin University, Changchun, 130012, China
| | - Xiaolin Zhang
- State Key Laboratory of Automotive Simulation and Control, Department of Materials Science, Jilin University, Changchun, 130012, China
| | - Ying Wang
- State Key Laboratory of Automotive Simulation and Control, Department of Materials Science, Jilin University, Changchun, 130012, China
| | - Lei Zhang
- State Key Laboratory of Automotive Simulation and Control, Department of Materials Science, Jilin University, Changchun, 130012, China
| | - Xiaoqiang Cui
- State Key Laboratory of Automotive Simulation and Control, Department of Materials Science, Jilin University, Changchun, 130012, China.
| |
Collapse
|
20
|
Amperometric nonenzymatic sensing of glucose at very low working potential by using a nanoporous PdAuNi ternary alloy. Mikrochim Acta 2018; 185:111. [PMID: 29594761 DOI: 10.1007/s00604-017-2665-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Accepted: 12/31/2017] [Indexed: 02/07/2023]
Abstract
The authors present a nonenzymatic sensor for glucose that has an exceedingly low working potential which makes the sensor highly selective over other electroactive species. The sensor is based on the use of a glassy carbon electrode (GCE) that was modified with a nanoporous PdAuNi alloy (np-PdAuNi). The PdAuNi alloy nanostructure displays enhanced electrocatalytic activity for glucose oxidation (compared to PdNi alloys). The modified GCE enables amperometric sensing of glucose at a typical working electrode potential of 0.0 V vs. SCE in solutions of pH 13 containing 0.1 M NaCl. Response is linear in the 5 to 100 μM concentration range, with a 1.7 μM detection limit (at an S/N ratio of 3). For higher concentrations deviations from linearity were found. The method is selective and reproducible. The modified electrode was applied to the determination of glucose in human serum. Graphical Abstract Nanoporous PdAuNi alloy with three-dimensional bicontinuous nanosponge architecture was successfully prepared via chemical dealloying. The electrochemical nonenzymatic glucose sensor shows a low working potential, wide linear range, good sensitivity, low detection limit and excellent selectivity.
Collapse
|
21
|
Electrochemical immunosensor for the breast cancer marker CA 15–3 based on the catalytic activity of a CuS/reduced graphene oxide nanocomposite towards the electrooxidation of catechol. Mikrochim Acta 2017; 185:79. [DOI: 10.1007/s00604-017-2532-5] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Accepted: 11/09/2017] [Indexed: 12/12/2022]
|
22
|
Foroughi F, Rahsepar M, Hadianfard MJ, Kim H. Microwave-assisted synthesis of graphene modified CuO nanoparticles for voltammetric enzyme-free sensing of glucose at biological pH values. Mikrochim Acta 2017; 185:57. [DOI: 10.1007/s00604-017-2558-8] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 11/09/2017] [Indexed: 02/07/2023]
|
23
|
Electrochemical nonenzymatic sensing of glucose using advanced nanomaterials. Mikrochim Acta 2017; 185:49. [PMID: 29594566 DOI: 10.1007/s00604-017-2609-1] [Citation(s) in RCA: 105] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 12/02/2017] [Indexed: 12/22/2022]
Abstract
An overview (with 376 refs.) is given here on the current state of methods for electrochemical sensing of glucose based on the use of advanced nanomaterials. An introduction into the field covers aspects of enzyme based sensing versus nonenzymatic sensing using nanomaterials. The next chapter cover the most commonly used nanomaterials for use in such sensors, with sections on uses of noble metals, transition metals, metal oxides, metal hydroxides, and metal sulfides, on bimetallic nanoparticles and alloys, and on other composites. A further section treats electrodes based on the use of carbon nanomaterials (with subsections on carbon nanotubes, on graphene, graphene oxide and carbon dots, and on other carbonaceous nanomaterials. The mechanisms for electro-catalysis are also discussed, and several Tables are given where the performance of sensors is being compared. Finally, the review addresses merits and limitations (such as the frequent need for working in strongly etching alkaline solutions and the need for diluting samples because sensors often have analytical ranges that are far below the glucose levels found in blood). We also address market/technology gaps in comparison to commercially available enzymatic sensors. Graphical Abstract Schematic representation of electrochemical nonenzymatic glucose sensing on the nanomaterials modified electrodes. At an applied potential, the nanomaterial-modified electrodes exhibit excellent electrocatalytic activity for direct oxidation of glucose oxidation.
Collapse
|
24
|
Molybdenum disulfide quantum dot based highly sensitive impedimetric immunoassay for prostate specific antigen. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2506-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
25
|
Zhang L, Ding Y, Li R, Ye C, Zhao G, Wang Y. Electrodeposition of ultra-long copper nanowires on a titanium foil electrode for nonenzymatic voltammetric sensing of glucose. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2279-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
26
|
Leonardi SG, Marini S, Espro C, Bonavita A, Galvagno S, Neri G. In-situ grown flower-like nanostructured CuO on screen printed carbon electrodes for non-enzymatic amperometric sensing of glucose. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2232-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
27
|
Hydrothermal deposition of CuO/rGO/Cu2O nanocomposite on copper foil for sensitive nonenzymatic voltammetric determination of glucose and hydrogen peroxide. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2229-9] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|