1
|
Gu Y, Liu L, Guo J, Xiao S, Fang F, Yu X, Gopinath SCB, Wu J, Liu X. Biomolecular assembly on interdigitated electrode nanosensor for selective detection of insulin-like growth factor-1. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2021; 49:30-37. [PMID: 33467925 DOI: 10.1080/21691401.2020.1865992] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
This research is focussed to quantify IGF1 by electroanalytical analysis on InterDigitated electrode surface and characterized by the microscopic observations. For the detection, antibody and aptamer were used to analyze the level of IGF1. The sandwich pattern (aptamer-IGF1-antibody) was designed on the chemically modified IDE surface and reached the limit of detection to 10 fM with 100 folds enhancement in the sensitivity. Different control experiments (absence of IGF1, binding with IGF2 and with non-complementary aptamer) were failed to show the current changes, discriminated the specific detection. A good detection strategy is to complement the currently following imaging systems for AAA.
Collapse
Affiliation(s)
- Yan Gu
- Department of Vascular Surgery, Tianjin First Center Hospital, Tianjin, China
| | - Lijie Liu
- Department of Pharmacy, The Affiliated Hospital of Qingdao University, Qingdao City, China
| | - Jian Guo
- Department of Imaging, The Affiliated Hospital of Qingdao University, Qingdao City, China
| | - Shun Xiao
- Department of Vascular Surgery, The Affiliated Hospital of Qingdao University, Qingdao City, China
| | - Fang Fang
- Department of Oncology, The Affiliated Hospital of Qingdao University, Qingdao City, China
| | - Xiaoyun Yu
- Department of Oncology, The Affiliated Hospital of Qingdao University, Qingdao City, China
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Perlis, Malaysia.,Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis (UniMAP), Perlis, Malaysia
| | - Jianlie Wu
- Department of Oncology, The Affiliated Hospital of Qingdao University, Qingdao City, China
| | - Xunqiang Liu
- Department of Vascular surgery, Yan'an Hospital Affiliated to Kunming Medical University, Kunming City, Yunnan Province, China
| |
Collapse
|
2
|
Letchumanan I, Arshad MKM, Gopinath SCB. Nanodiagnostic Attainments and Clinical Perspectives on C-Reactive Protein: Cardiovascular Disease Risks Assessment. Curr Med Chem 2021; 28:986-1002. [PMID: 31971105 DOI: 10.2174/0929867327666200123092648] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/12/2019] [Accepted: 10/18/2019] [Indexed: 01/08/2023]
Abstract
Cardiovascular disease (CVD) has become one of the leading causes of morbidity and mortality in both men and women. According to the World Health Organization (WHO), ischemic heart disease is the major issue due to the narrowing of the coronary artery by plaque formation on the artery wall, which causes an inadequate flow of oxygen and blood to the heart and is called 'coronary artery disease'. The CVD death rate increased by up to 15% in 2016 (~17.6 million) compared to the past decade. This tremendous increment urges the development of a suitable biomarker for rapid and early diagnosis. Currently, C-reactive protein (CRP) is considered an outstanding biomarker for quick and accurate outcomes in clinical analyses. Various techniques have also been used to diagnose CVD, including surface plasmon resonance (SPR), colorimetric assay, enzyme-linked immunosorbent assay (ELISA), fluoro-immunoassays, chemiluminescent assays, and electrical measurements. This review discusses such diagnostic strategies and how current, cutting-edge technologies have enabled the development of high-performance detection methodologies. Concluding remarks have been made concerning the clinical significance and the use of nanomaterial in medical diagnostics towards nanotheranostics.
Collapse
Affiliation(s)
- Iswary Letchumanan
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - M K Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| |
Collapse
|
3
|
Wang Y, Sun X, Gopinath SCB, Saheed MSM, Wang X. Thyroglobulin determination on silane-antibody functionalized interdigitated dielectrode surface to diagnose thyroid tumor. Biotechnol Appl Biochem 2021; 69:376-382. [PMID: 33538049 DOI: 10.1002/bab.2116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 01/06/2021] [Indexed: 12/13/2022]
Abstract
Thyroid cancer appears in endocrine glands and specific to thyroid glands has been reported widely. This work was targeted to identify and quantify thyroglobulin by using antithyroglobulin antibody complexed silane surface on interdigitated electrode (IDE) sensing surface. (3-Aminopropyl)triethoxysilane linker was used to make silane-coupling with antibody and attached on the hydroxylated IDE. This electroanalytical IDE revealed the dose-dependent responses with thyroglobulin concentrations. By getting increments with the thyroglobulin concentrations, the current responses were enhanced concomitantly and the thyroglobulin detection limit was noted as 1 pM on the linear curve [y = 0.1311x + 0.5386; R² = 0.9707] with the sensitivity at lower picomolar range. Moreover, the control experiments with thyroid peroxidase and nonimmune antibody cannot yield any response of current, confirming the specific detection of thyroglobulin. This research set-up is useful to determine and quantify the thyroglobulin and diagnose thyroid cancer.
Collapse
Affiliation(s)
- Yujie Wang
- Department of Clinical Laboratory, Qingdao Municipal Hospital, Qingdao, Shandong, People's Republic of China
| | - Xia Sun
- Department of Clinical Laboratory, Qingdao Women and Children's Hospital, Qingdao, Shandong, People's Republic of China
| | - Subash C B Gopinath
- Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis, Arau, Perlis, 02600, Malaysia.,Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar, Perlis, 01000, Malaysia
| | - Mohamed Shuaib Mohamed Saheed
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.,Centre of Innovative Nanostructure & Nanodevices, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Xiaofei Wang
- Department of Oncology, Qingdao Municipal Hospital, Qingdao, Shandong, People's Republic of China
| |
Collapse
|
4
|
Letchumanan I, Gopinath SCB, Md Arshad MK, Mohamed Saheed MS, Perumal V, Voon CH, Hashim U. Gold-Nanohybrid Biosensors for Analyzing Blood Circulating Clinical Biomacromolecules: Current Trend toward Future Remote Digital Monitoring. Crit Rev Anal Chem 2020; 52:577-592. [PMID: 32897761 DOI: 10.1080/10408347.2020.1812373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Mortality level is worsening the situation worldwide thru blood diseases and greatly jeopardizes the human health with poor diagnostics. Due to the lack of successful generation of early diagnosis, the survival rate is currently lower. To overcome the present hurdle, new diagnostic methods have been choreographed for blood disease biomarkers analyses with the conjunction of ultra-small ideal gold nanohybrids. Gold-hybrids hold varieties of unique features, such as high biocompatibility, increased surface-to-volume ratio, less-toxicity, ease in electron transfer and have a greater localized surface plasmon resonance. Gold-nanocomposites can be physically hybrid on the sensor surface and functionalize with the biomolecules using appropriate chemical conjugations. Revolutionizing biosensor platform can be prominently linked for the nanocomposite applications in the current research on medical diagnosis. This review encloses the new developments in diagnosing blood biomarkers by utilizing the gold-nanohybrids. Further, the current state-of-the-art and the future envision with digital monitoring for facile telediagnosis were narrated.
Collapse
Affiliation(s)
- Iswary Letchumanan
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar 01000, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar 01000, Malaysia.,School of Bioprocess Engineering, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - M K Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar 01000, Malaysia.,School of Microelectronic Engineering, Arau 02600, Universiti Malaysia Perlis, Perlis, Malaysia
| | - Mohamed Shuaib Mohamed Saheed
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.,Centre of Innovative Nanostructures & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Veeradasan Perumal
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.,Centre of Innovative Nanostructures & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Chun Hong Voon
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar 01000, Malaysia
| | - Uda Hashim
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar 01000, Malaysia
| |
Collapse
|
5
|
Comparative Analysis on Dielectric Gold and Aluminium Triangular Junctions: Impact of Ionic Strength and Background Electrolyte by pH Variations. Sci Rep 2020; 10:6783. [PMID: 32321969 PMCID: PMC7176652 DOI: 10.1038/s41598-020-63831-w] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 02/27/2020] [Indexed: 11/23/2022] Open
Abstract
Field of generating a surface thin film is emerging broadly in sensing applications to obtain the quick and fast results by forming the high-performance sensors. Incorporation of thin film technologies in sensor development for the better sensing could be a promising way to attain the current requirements. This work predominantly delineates the fabrication of the dielectric sensor using two different sensing materials (Gold and Aluminium). Conventional photolithography was carried out using silicon as a base material and the photo mask of the dielectric sensor was designed by AutoCAD software. The physical characterization of the fabricated sensor was done by Scanning Electron Microscope, Atomic Force Microscope, High Power Microscope and 3D-nano profiler. The electrical characterization was performed using Keithley 6487 picoammeter with a linear sweep voltage of 0 to 2 V at 0.01 V step voltage. By pH scouting, I-V measurements on the bare sensor were carried out, whereby the gold electrodes conducts a least current than aluminium dielectrodes. Comparative analysis with pH scouting reveals that gold electrode is suitable under varied ionic strengths and background electrolytes, whereas aluminium electrodes were affected by the extreme acid (pH 1) and alkali (pH 12) solutions.
Collapse
|
6
|
Divalent ion-induced aggregation of gold nanoparticles for voltammetry Immunosensing: comparison of transducer signals in an assay for the squamous cell carcinoma antigen. Mikrochim Acta 2020; 187:128. [DOI: 10.1007/s00604-020-4115-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Accepted: 01/03/2020] [Indexed: 01/24/2023]
|
7
|
Letchumanan I, Md Arshad M, Balakrishnan S, Gopinath SC. Gold-nanorod enhances dielectric voltammetry detection of c-reactive protein: A predictive strategy for cardiac failure. Biosens Bioelectron 2019; 130:40-47. [DOI: 10.1016/j.bios.2019.01.042] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Revised: 12/26/2018] [Accepted: 01/14/2019] [Indexed: 12/31/2022]
|
8
|
Letchumanan I, Gopinath SCB, Md Arshad MK, Anbu P, Lakshmipriya T. Gold nano-urchin integrated label-free amperometric aptasensing human blood clotting factor IX: A prognosticative approach for "Royal disease". Biosens Bioelectron 2019; 131:128-135. [PMID: 30826647 DOI: 10.1016/j.bios.2019.02.006] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Accepted: 02/06/2019] [Indexed: 12/16/2022]
Abstract
This article is clearly presenting the development of a biosensor for human factor IX (FIX) to diagnose the blood clotting deficiency, a so-called 'Royal disease' using an interdigitated electrode (IDE) with the zinc oxide surface modification. Gold nano-urchins (GNUs) with 60 nm in diameter was integrated into a streptavidin-biotinylated aptamer strategy to enhance the active surface area. Two different comparative studies have been done to validate the system to be practiced in the current work holds with a higher capability for the high-performance sense. Whereby, the presence and absence of GNUs in the aptasensing system for FIX interaction were investigated using the amperometric measurement, using a linear sweep voltage of 0-2 V at 0.01 V step voltage. The detection limit was 6 pM based on 3σ calculation when GNUs integrated aptamer assay was utilized for FIX detection, which shows 8 folds sensitivity enhancement comparing the condition in the absence of GNU and 50 folds higher than sensitive radio-isotope and surface plasmon resonance assays. Albeit, the surface and molecular characterizations were well demonstrated by scanning electron microscopy, atomic force microscopy, 3D nano-profilometry and further supports were rendered by UV-Vis spectroscopy and Enzyme-linked apta-sorbent assay (ELASA). Furthermore, the spiking experiment was done by FIX-spikes in human blood serum in order to demonstrate the stability with a higher non-fouling.
Collapse
Affiliation(s)
- Iswary Letchumanan
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia; School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
| | - M K Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia; School of Microelectronic Engineering, Universiti Malaysia Perlis, Pauh Putra, Arau 02600, Perlis, Malaysia
| | - Periasamy Anbu
- Department of Biological Engineering, College of Engineering, Inha University, Incheon 402-751, Republic of Korea
| | - Thangavel Lakshmipriya
- Centre of Innovative Nanostructure & Nanodevices, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak Darul Ridzuan, Malaysia
| |
Collapse
|