1
|
Karimi-Maleh H, Darabi R, Karimi F, Karaman C, Shahidi SA, Zare N, Baghayeri M, Fu L, Rostamnia S, Rouhi J, Rajendran S. State-of-art advances on removal, degradation and electrochemical monitoring of 4-aminophenol pollutants in real samples: A review. ENVIRONMENTAL RESEARCH 2023; 222:115338. [PMID: 36702186 DOI: 10.1016/j.envres.2023.115338] [Citation(s) in RCA: 73] [Impact Index Per Article: 73.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 12/26/2022] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
p_Aminophenol, namely 4-aminophenol (4-AP), is an aromatic compound including hydroxyl and amino groups contiguous together on the benzene ring, which are suitable chemically reactive, amphoteric, and alleviating agents in nature. Amino phenols are appropriate precursors for synthesizing oxazoles and oxazines. However, since the toxicity of aniline and phenol can harm human and herbal organs, it is essential to improve a reliable technique for the determination of even a trace amount of amino phenols, as well as elimination or (bio)degradation/photodegradation of it to protect both the environment and people's health. For this purpose, various analytical methods have been suggested up till now, including spectrophotometry, liquid chromatography, spectrofluorometric and capillary electrophoresis, etc. However, some drawbacks such as the requirement of complex instruments, high costs, not being portable, slow response time, low sensitivity, etc. prevent them to be employed in a wide range and swift in-situ applications. In this regard, besides the efforts such as (bio)degradation/photodegradation or removal of 4-AP pollutants from real samples, electroanalytical techniques have become a promising alternative for monitoring them with high sensitivity. In this review, it was aimed to emphasize and summarize the recent advances, challenges, and opportunities for removal, degradation, and electrochemical sensing 4-AP in real samples. Electroanalytical monitoring of amino phenols was reviewed in detail and explored the various types of electrochemical sensors applied for detecting and monitoring in real samples. Furthermore, the various technique of removal and degradation of 4-AP in industrial and urban wastes were also deliberated. Moreover, deep criticism of multifunctional nanomaterials to be utilized as a catalyst, adsorbent/biosorbent, and electroactive material for the fabrication of electrochemical sensors was covered along with their unique properties. Future perspectives and conclusions were also criticized to pave the way for further studies in the field of application of up-and-coming nanostructures in environmental applications.
Collapse
Affiliation(s)
- Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China; Department of Chemical Engineering and Energy, Quchan University of Technology, Quchan, 9477177870, Iran; Department of Sustainable Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602105, India.
| | - Rozhin Darabi
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China
| | - Fatemeh Karimi
- Department of Chemical Engineering and Energy, Quchan University of Technology, Quchan, 9477177870, Iran.
| | - Ceren Karaman
- Department of Electricity and Energy, Akdeniz University, Antalya, 07070, Turkey; School of Engineering, Lebanese American University, Byblos, Lebanon.
| | - Seyed Ahmad Shahidi
- Department of Food Science and Technology, Ayatollah Amoli Branch, Islamic Azad University, Amol, Iran
| | - Najmeh Zare
- Department of Chemical Engineering and Energy, Quchan University of Technology, Quchan, 9477177870, Iran
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, PO. Box 397, Sabzevar, Iran
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Sadegh Rostamnia
- Organic and Nano Group (ONG), Department of Chemistry, Iran University of Science and Technology (IUST), PO Box 16846-13114, Tehran, Iran
| | - Jalal Rouhi
- Faculty of Physics, University of Tabriz, Tabriz, 51566, Iran
| | - Saravanan Rajendran
- Faculty of Engineering, Department of Mechanical Engineering, University of Tarapacá, Avda, General Velasquez, 1775, Arica, Chile
| |
Collapse
|
2
|
A sensitive method for the determination of 4-aminophenol using an electrochemical sensor based on 5-amino-1,3,4-thiadiazole-2-thiol. J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2022.104728] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
3
|
Okla MK, Balasurya S, Alaraidh IA, Mohebaldin A, Al-Ghamdi AA, Al-Okla MA, Abdel-Maksoud MA, Abdelaziz RF, Soufan W, Balakrishnaraja R, Raju LL, Thomas AM, Sudheer Khan S. Plasma-assisted in-situ preparation of L-cystine functionalized silver nanoparticle: An intelligent multicolor nano-sensing of cadmium and paracetamol from environmental sample. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 279:121330. [PMID: 35605418 DOI: 10.1016/j.saa.2022.121330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/25/2022] [Accepted: 04/27/2022] [Indexed: 06/15/2023]
Abstract
L-cystine (L-cys) functionalized plasmonic silver nanomaterial (Ag NPs) was fabricated toward the selective and sensitive detection of paracetamol and cadmium. The prepared L-cys-Ag nanoparticles (NPs) were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction spectroscopy (XRD) and fourier transform infrared spectroscopy (FTIR) analyses. SEM imaging show that Ag NPs was decorated on the surface of L-cysteine 3D cubic nanosheet. L-cys-Ag NPs showed selective and sensitive detection towards paracetamol and cadmium. The interference study confirms that the presence of other metal ions didn't inhibit the detection of cadmium by L-cys-Ag NPs. The limit of detection of paracetamol and cadmium by L-cys-Ag NPs was calculated to be 1.2 and 2.82 nM respectively. In addition, the real sample detection of paracetamol on blood serum and urine, and cadmium on STP were performed and the recovery percentage was above 97%. Further, the real sample analysis was performed in tap and drinking water and the recovery percentage was more than 98%. The analytic logic gate on the multicolour detection of cadmium and paracetamol was performed for the semi-quantitative monitoring of paracetamol and cadmium by L-cys-Ag NPs. The developed L-cys-Ag NPs were found to be an effective tool for the monitoring of cadmium in environmental water bodies and paracetamol in blood and urine.
Collapse
Affiliation(s)
- Mohammad K Okla
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - S Balasurya
- Nanobiotechnology Laboratory, Department of Biotechnology, Bannari Amman Institute of Technology, Sathyamangalam, Tamil Nadu, India
| | - Ibrahim A Alaraidh
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Asmaa Mohebaldin
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Abdullah A Al-Ghamdi
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Mohammed A Al-Okla
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Mostafa A Abdel-Maksoud
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Ramadan F Abdelaziz
- Department of Pharmaceutical Sciences, Division of Pharmacology and Toxicology, University of Vienna, Austria
| | - Walid Soufan
- College of Food and Agriculture Sciences, King Saud University. P.O. Box 2460, Riyadh 11451, Saudi Arabia
| | - R Balakrishnaraja
- Nanobiotechnology Laboratory, Department of Biotechnology, Bannari Amman Institute of Technology, Sathyamangalam, Tamil Nadu, India
| | - Lija L Raju
- Department of Zoology, Mar Ivanios College, Nalanchira, Thiruvananthapuram, India
| | - Ajith M Thomas
- Department of Botany and Biotechnology, St Xavier's College, Thumba, Thiruvananthapuram, India
| | - S Sudheer Khan
- Nanobiotechnology Laboratory, Department of Biotechnology, Bannari Amman Institute of Technology, Sathyamangalam, Tamil Nadu, India.
| |
Collapse
|
4
|
|
5
|
Jahani PM, Beitollahi H, Nejad FG, Dourandish Z, Di Bartolomeo A. Screen-printed graphite electrode modified with Co 3O 4nanoparticles and 2D graphitic carbon nitride as an effective electrochemical sensor for 4-aminophenol detection. NANOTECHNOLOGY 2022; 33:395702. [PMID: 35688102 DOI: 10.1088/1361-6528/ac779f] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/10/2022] [Indexed: 06/15/2023]
Abstract
We fabricated a new electrochemical 4-aminophenol sensor based on a nanocomposite of Co3O4nanoparticles and graphite carbon nitride (Co3O4@g-C3N4), used for the modification of a screen-printed electrode (Co3O4@g-C3N4/SPE). The synthesized nanocomposite was characterized using field-emission scanning electron microscopy, energy-dispersive x-ray spectroscopy, x-ray diffraction and Fourier transform-infrared (FT-IR) techniques. The electro-oxidation of 4-aminophenol in phosphate buffer solution (pH = 7.0) was investigated via cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The peak current of oxidation in the optimized conditions had a linear relationship with various 4-aminophenol contents (0.05-780.0μM) with a correlation coefficient of 0.9996 and the limit of detection (S/N = 3) of 1.5 × 10-8M. The developed method was successful to determine 4-aminophenol in real specimens, with acceptable outcomes.
Collapse
Affiliation(s)
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Antonio Di Bartolomeo
- Department of Physics 'E.R. Caianiello', University of Salerno, I-84084 Fisciano, Salerno, Italy
| |
Collapse
|
6
|
Hashemzaei Z, Saravani H, Sharifitabar M, Shahbakhsh M. Copper nanowires / poly (naphtoquinone chromium (III)) for simultaneous voltammetric detection of para - aminophenol, phenol and para - nitrophenol. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
7
|
Wang R, Qin Y, Liu X, Li Y, Lin Z, Nie R, Shi Y, Huang H. Electrochemical Biosensor Based on Well-Dispersed Boron Nitride Colloidal Nanoparticles and DNA Aptamers for Ultrasensitive Detection of Carbendazim. ACS OMEGA 2021; 6:27405-27411. [PMID: 34693161 PMCID: PMC8529661 DOI: 10.1021/acsomega.1c04326] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 09/20/2021] [Indexed: 05/27/2023]
Abstract
A selective electrochemical biosensor was developed for detecting carbendazim (CBZ) based on well-dispersed colloidal boron nitride (BN) nanocrystals and gold nanoparticles (Au NPs). BN was synthesized by "solvent cutting" to modify a glassy carbon electrode (GCE), and Au NPs were then electrodeposited. A single-stranded oligonucleotide with methylene blue (MB) was modified to the electrode surface through gold-sulfur bonds. A double-stranded DNA was formed in the presence of an aptamer. The aptamer chain can specifically bind to the target CBZ. When the aptamer binds to CBZ, the electroactive substance MB labeled at one end of the complementary chain can effectively contact the electrode surface. Detection of CBZ is realized by simultaneously monitoring the MB signal enhancement. The CBZ concentration was determined in a wide linearity range from 0.1 ng mL-1 to 100 μg mL-1, with a low detection limit of 0.019 ng mL-1. This biosensor exhibited excellent selectivity and acceptable repeatability and was applied in cucumber, kiwifruit, and water samples with good recoveries, demonstrating that the strategy has remarkable potential and offers a good platform for CBZ detection.
Collapse
Affiliation(s)
- Ruijie Wang
- Shaanxi Key Laboratory
of Earth Surface System and Environmental Carrying Capacity, College
of Urban and Environmental Science, Northwest
University, Xi’an 710127, China
- Key Laboratory
of Watershed Geographic Sciences, Nanjing Institute of Geography and
Limnology, Chinese Academy of Sciences, Nanjing 210008, China
| | - Yuan Qin
- Shaanxi Key Laboratory
of Earth Surface System and Environmental Carrying Capacity, College
of Urban and Environmental Science, Northwest
University, Xi’an 710127, China
- Key Laboratory
of Watershed Geographic Sciences, Nanjing Institute of Geography and
Limnology, Chinese Academy of Sciences, Nanjing 210008, China
| | - Xin Liu
- Shaanxi Key Laboratory
of Earth Surface System and Environmental Carrying Capacity, College
of Urban and Environmental Science, Northwest
University, Xi’an 710127, China
| | - Yangzi Li
- Shaanxi Key Laboratory
of Earth Surface System and Environmental Carrying Capacity, College
of Urban and Environmental Science, Northwest
University, Xi’an 710127, China
| | - Zhenfeng Lin
- Shaanxi Key Laboratory
of Earth Surface System and Environmental Carrying Capacity, College
of Urban and Environmental Science, Northwest
University, Xi’an 710127, China
| | - Rong Nie
- School of Chemistry and Chemical Engineering, Lanzhou City University, Lanzhou 730070, China
| | - Yifei Shi
- Shaanxi Environment Investigation and Assessment Center, Xi’an 710054, China
| | - Huayu Huang
- Shaanxi Key Laboratory
of Earth Surface System and Environmental Carrying Capacity, College
of Urban and Environmental Science, Northwest
University, Xi’an 710127, China
- Key Laboratory
of Watershed Geographic Sciences, Nanjing Institute of Geography and
Limnology, Chinese Academy of Sciences, Nanjing 210008, China
| |
Collapse
|
8
|
Li Y, Li Y, Wang Y, Ma G, Liu X, Li Y, Soar J. Application of zeolitic imidazolate frameworks (ZIF-8)/ionic liquid composites modified nano-carbon paste electrode as sensor for electroanalytical sensing of 1-hydroxypyrene. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105433] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
9
|
Li G, Sun P, Wu F, Zhao J, Han D, Cui G. Significant enhancement in the electrochemical determination of 4-aminophenol from nanoporous gold by decorating with a Pd@CeO2 composite film. NEW J CHEM 2020. [DOI: 10.1039/c9nj05728e] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
An electrode based on Pd@CeO2 nanocomposite-decorated nanoporous gold on a carbon fiber paper was achieved, which demonstrated excellent performance in 4-aminophenol determination.
Collapse
Affiliation(s)
- Gang Li
- School of Mechanical and Automotive Engineering
- South China University of Technology
- Guangzhou 510640
- P. R. China
| | - Peng Sun
- Key Laboratory for Polymeric Composite & Functional Materials of Ministry of Education
- School of Chemistry
- Sun Yat-sen University
- Guangzhou 510275
- P. R. China
| | - Fanggen Wu
- School of Mechanical and Automotive Engineering
- South China University of Technology
- Guangzhou 510640
- P. R. China
| | - Jie Zhao
- School of Mechanical and Automotive Engineering
- South China University of Technology
- Guangzhou 510640
- P. R. China
| | - Dongxue Han
- Center for Advanced Analytical Science
- c/o School of Chemistry and Chemical Engineering
- Guangzhou University
- Guangzhou 510006
- P. R. China
| | - Guofeng Cui
- Key Laboratory for Polymeric Composite & Functional Materials of Ministry of Education
- School of Chemistry
- Sun Yat-sen University
- Guangzhou 510275
- P. R. China
| |
Collapse
|
10
|
|