1
|
Regiart M, Fernández-Baldo MA, Navarrete BA, Morales García C, Gómez B, Tortella GR, Valero T, Ortega FG. Five years of advances in electrochemical analysis of protein biomarkers in lung cancer: a systematic review. Front Chem 2024; 12:1390050. [PMID: 38764920 PMCID: PMC11099832 DOI: 10.3389/fchem.2024.1390050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 04/01/2024] [Indexed: 05/21/2024] Open
Abstract
Lung cancer is the leading cause of cancer death in both men and women. It represents a public health problem that must be addressed through the early detection of specific biomarkers and effective treatment. To address this critical issue, it is imperative to implement effective methodologies for specific biomarker detection of lung cancer in real clinical samples. Electrochemical methods, including microfluidic devices and biosensors, can obtain robust results that reduce time, cost, and assay complexity. This comprehensive review will explore specific studies, methodologies, and detection limits and contribute to the depth of the discussion, making it a valuable resource for researchers and clinicians interested in lung cancer diagnosis.
Collapse
Affiliation(s)
- Matías Regiart
- Instituto de Química San Luis (INQUISAL), Departamento de Química, Universidad Nacional de San Luis, CONICET, San Luis, Argentina
| | - Martín A. Fernández-Baldo
- Instituto de Química San Luis (INQUISAL), Departamento de Química, Universidad Nacional de San Luis, CONICET, San Luis, Argentina
| | - Bernardino Alcázar Navarrete
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
- CIBERES, Instituto de Salud Carlos III, Madrid, Spain
| | - Concepción Morales García
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
| | - Beatriz Gómez
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
| | - Gonzalo R. Tortella
- Centro de Excelencia en Investigación Biotecnológica Aplicada al Medio Ambiente (CIBAMA), Facultad de Ingeniería y Ciencias, Universidad de La Frontera, Temuco, Chile
- Departamento de Ingeniería Química, Facultad de Ingeniería y Ciencias, Universidad de La Frontera, Temuco, Chile
| | - Teresa Valero
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Department of Medicinal and Organic Chemistry and Excellence Research Unit of “Chemistry Applied to Biomedicine and the Environment”, Faculty of Pharmacy, University of Granada, Granada, Spain
| | - Francisco Gabriel Ortega
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
- GENYO, Centre for Genomics and Oncological Research, Pfizer/University of Granada/Andalusian Regional Government, Granada, Spain
- UGC Cartuja, Distrito Sanitario Granada Metropolitano, Granada, Spain
| |
Collapse
|
2
|
Jin Z, Sheng W, Liu J, Liu C, Ma Y, Wang S, Zhang W, Huang N. A fluorescence immunoassay based on GSH destroying MnO 2@QDs for the simultaneous ultrasensitive detection of four mycotoxins in cereals. Food Chem 2023; 420:136099. [PMID: 37037114 DOI: 10.1016/j.foodchem.2023.136099] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 03/26/2023] [Accepted: 03/31/2023] [Indexed: 04/12/2023]
Abstract
A novel fluorescence immunoassay based on MnO2 nanoflowers loading multicolor quantum dots and glutathione destroying MnO2 nanoflowers to release quantum dots combined with magnetic separation is developed for rapid, ultra-sensitive, and simultaneous quantitative detection of ochratoxin A, aflatoxin B1, fumonisin B1, and zearalenone in cereal samples. The test linear range of assay is from 0.001 to 200 μg L-1. The limit of detection for ochratoxin A, aflatoxin B1, fumonisin B1, and zearalenone is 0.0001 μg L-1, 0.0001 μg L-1, 0.0003 μg L-1, and 0.0001 μg L-1, respectively. The simultaneous detection of four mycotoxins can be achieve within 30 min. The test results of four mycotoxins in the incurred corn, rice, and oat samples have been confirmed by ultra-performance liquid chromatography tandem mass spectrometry, the differences between results are considered no significantly different (p > 0.05). This multiplexed test scheme has provided a potential analysis strategy for multiple food risk factors.
Collapse
Affiliation(s)
- Zixin Jin
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Wei Sheng
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Junli Liu
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Chenchen Liu
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Yueru Ma
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Shuo Wang
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China
| | - Wanli Zhang
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Na Huang
- State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Food Nutrition and Safety, Ministry of Education, Key Laboratory of Food Quality and Health of Tianjin, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| |
Collapse
|
3
|
Wang J, Yang X, Hua X, Li Y, Jin B. Novel Ratiometric Electrochemical Biosensor for Determination of Cytokeratin 19 Fragment Antigen 21-1 (Cyfra-21-1) as a Lung Cancer Biomarker. ANAL LETT 2023. [DOI: 10.1080/00032719.2023.2181970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Affiliation(s)
- Jiajia Wang
- Department of Chemistry, Anhui University, Hefei, China
| | - Xiaomin Yang
- Respiratory Medicine Department, The First People’s Hospital of Chuzhou, Chuzhou, China
| | - Xin Hua
- Department of Chemistry, Anhui University, Hefei, China
| | - Yanan Li
- Department of Chemistry, Anhui University, Hefei, China
| | - Baokang Jin
- Department of Chemistry, Anhui University, Hefei, China
| |
Collapse
|
4
|
Liu L, Sun C, Liu J, Du Y, Xie Q. Photoelectrochemical sandwich immunoassay of CYFRA21-1 based on In 2O 3/WO 3 type-II heterojunction and CdS quantum dots-polydopamine nanospheres labeling. Analyst 2022; 147:2678-2686. [PMID: 35611759 DOI: 10.1039/d2an00522k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Using an In2O3/WO3 type-II heterojunction modified fluorine-doped tin oxide (FTO) electrode as the photoanode and CdS quantum dots (QDs)-polydopamine nanospheres (PDA NSs) as the secondary antibody (Ab2) label, the photoelectrochemistry (PEC) sandwich immunosensing of the lung cancer marker CYFRA21-1 was studied. WO3 nanoplates were prepared by a hydrothermal method, In2O3 nanoporous spheres were prepared by a hydrothermal method followed by calcination, and the In2O3/WO3 type-II heterojunction with high PEC activity was prepared by ultrasonic mixing and cast-coating. PDA NSs with a high surface area can be loaded with abundant Ab2 molecules and many CdS QDs with an energy level well matched with the heterojunction, so the photocurrent signal can be amplified by the formation of a sandwich immunostructure. Through the simulation experiments of photoelectrode-modified chitosan films of varying thickness, the effective transport distance of photogenerated charges is preliminarily discussed. Under the optimized conditions, the photocurrent was linear with the common logarithm of CYFRA21-1 concentration from 100 fg mL-1 to 50 ng mL-1, with a limit of detection of 56 fg mL-1 (S/N = 3). The immunoassay of CYFRA21-1 in human serum samples gave satisfactory recovery results.
Collapse
Affiliation(s)
- Luyao Liu
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, China.
| | - Chenglong Sun
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, China.
| | - Jialin Liu
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, China.
| | - Yun Du
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, China.
| | - Qingji Xie
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, China.
| |
Collapse
|
5
|
Ren L, Wang L, Rehberg M, Stoeger T, Zhang J, Chen S. Applications and Immunological Effects of Quantum Dots on Respiratory System. Front Immunol 2022; 12:795232. [PMID: 35069577 PMCID: PMC8770806 DOI: 10.3389/fimmu.2021.795232] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 12/13/2021] [Indexed: 12/29/2022] Open
Abstract
Quantum dots (QDs), are one kind of nanoscale semiconductor crystals with specific electronic and optical properties, offering near-infrared mission and chemically active surfaces. Increasing interest for QDs exists in developing theranostics platforms for bioapplications such as imaging, drug delivery and therapy. Here we summarized QDs' biomedical applications, toxicity, and immunological effects on the respiratory system. Bioapplications of QDs in lung include biomedical imaging, drug delivery, bio-sensing or diagnosis and therapy. Generically, toxic effects of nanoparticles are related to the generation of oxidative stresses with subsequent DNA damage and decreased lung cells viability in vitro and in vivo because of release of toxic metal ions or the features of QDs like its surface charge. Lastly, pulmonary immunological effects of QDs mainly include proinflammatory cytokines release and recruiting innate leukocytes or adaptive T cells.
Collapse
Affiliation(s)
- Laibin Ren
- Institute of Respiratory Diseases, Shenzhen People’s Hospital, Jinan University, Shenzhen, China
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Lingwei Wang
- Institute of Respiratory Diseases, Shenzhen People’s Hospital, Jinan University, Shenzhen, China
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Markus Rehberg
- Comprehensive Pneumology Center, Institute of Lung Biology and Disease, Helmholtz Center Munich, German Research Center for Environmental Health, Neuherberg and Member of the German Center for Lung Research, Munich, Germany
| | - Tobias Stoeger
- Comprehensive Pneumology Center, Institute of Lung Biology and Disease, Helmholtz Center Munich, German Research Center for Environmental Health, Neuherberg and Member of the German Center for Lung Research, Munich, Germany
| | - Jianglin Zhang
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
- Department of Dermatology, Shenzhen People’s Hospital, Jinan University, Shenzhen, China
| | - Shanze Chen
- Institute of Respiratory Diseases, Shenzhen People’s Hospital, Jinan University, Shenzhen, China
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| |
Collapse
|
6
|
Lv X, Bi M, Xu X, Li Y, Geng C, Cui B, Fang Y. An ultrasensitive ratiometric immunosensor based on the ratios of conjugated distyrylbenzene derivative nanosheets with AIECL properties and electrochemical signal for CYFRA21-1 detection. Anal Bioanal Chem 2021; 414:1389-1402. [PMID: 34741181 DOI: 10.1007/s00216-021-03764-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 10/25/2021] [Accepted: 10/28/2021] [Indexed: 02/04/2023]
Abstract
Aggregation-induced electrochemiluminescence reagent, a distyrylbenzene derivative with donor-acceptor conjugated nanosheet structure, namely TPAPCN, was used as a trace label and modified on the electrode through the formation of classical sandwich complex of antibody-antigen-antibody in this work. In aggregate state, TPAPCN with twisted structure was limited in nanometer space through intermolecular π - π stacking interactions, which not only restricts the intramolecular motions but also combines a large number of singlet excitons to greatly trigger electrochemiluminescence (ECL). The ECL signal of this system enhanced with more captured cytokeratin 19 fragment 21-1 (CYFRA21-1) on the modified electrode. Three-dimensional graphene/platinum nanoparticles with large specific surface, and excellent electroconductivity and biocompatibility were prepared and acted as excellent carriers for thionine handling (3D-GN/PtNPs/Th), which was employed for improving the loading of antibodies and generating internal electrochemical signal. Consequently, a novel ratiometric sandwich immunosensor for CYFRA21-1 detection was fabricated based on TPAPCN and 3D-GN/PtNPs/Th, that is, a rapid and reliable detection was achieved through the ratio between ECL and electrochemical signals. The prepared sensor performed good linearity in the range of 50 fg/mL to 1 ng/mL with a detection limit as low as 16 fg/mL. Moreover, the detection results revealed well in the analysis of human serum samples, demonstrating a significant application for clinical monitoring and biomolecules detection.
Collapse
Affiliation(s)
- Xiaoyi Lv
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, Shandong, China
| | - Mengmeng Bi
- Juye County People's Hospital, Heze, 274900, Shandong, People's Republic of China
| | - Xiaoyun Xu
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, Shandong, China
| | - Yanping Li
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, Shandong, China
| | - Chao Geng
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, Shandong, China
| | - Bo Cui
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, Shandong, China
| | - Yishan Fang
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, Shandong, China.
| |
Collapse
|
7
|
Asbaghian-Namin H, Karami P, Naghshara H, Gholamin D, Johari-Ahar M. Electrochemiluminescent immunoassay for the determination of CA15-3 and CA72-4 using graphene oxide nanocomposite modified with CdSe quantum dots and Ru(bpy) 3 complex. Mikrochim Acta 2021; 188:238. [PMID: 34184115 DOI: 10.1007/s00604-021-04890-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 06/10/2021] [Indexed: 11/30/2022]
Abstract
A novel immunoassay is introduced based on co-reactant enhancing strategy for the electrochemiluminescent (ECL) determination of CA15-3 and CA72-4 tumor markers in real samples. For the preparation of the signaling probe, CA15-3 and CA72-4 antibodies first were labeled using Ru(bpy)32+-N-hydroxysuccinimide ester (Ru(bpy)32+-NHS) and conjugated with L-cysteine capped cadmium selenide (CdSe) quantum dots. Finally, it was cross-linked with chitosan-grafted graphene oxide (GO@CS) nanocomposite. The capture probe was constructed by deposition of multi-walled carbon nanotubes (MWCNT) at the surface of dual-working gold screen-printed electrodes (MWCNT-dwSPE) and covalent attachment of capture CA15-3 and CA72-4 antibodies to MWCNT-dwSPE. ECL signals were recorded by applying cyclic potential ranging from 0.3 to 1.1 V (vs. pseudo-reference Ag/AgCl) at the scan rate of 100 mV.s-1. This immunoassay was used for determination of CA15-3 and CA72-4 in real samples the detection limits of 9.2 μU.ml-1 and 89 μU.ml-1 within linear ranges of 10 μU.ml-1-500 U.ml-1 and 100 μU.ml-1-150 U.ml-1, respectively. This immunoassay also showed acceptable accuracy with recoveries in the range 96.5-108 % and high reproducibility with RSD of 3.1 and 4.9.
Collapse
Affiliation(s)
- Hosein Asbaghian-Namin
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran.,School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Pari Karami
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Hamid Naghshara
- School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran
| | | | - Mohammad Johari-Ahar
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran. .,School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran.
| |
Collapse
|
8
|
Amri C, Shukla AK, Lee JH. Recent Advancements in Nanoparticle-Based Optical Biosensors for Circulating Cancer Biomarkers. MATERIALS (BASEL, SWITZERLAND) 2021; 14:1339. [PMID: 33802028 PMCID: PMC8001438 DOI: 10.3390/ma14061339] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/05/2021] [Accepted: 03/08/2021] [Indexed: 01/18/2023]
Abstract
The effectiveness of cancer treatment strongly depends on the early detection of the disease. Currently, the most common diagnostic method, tissue biopsy, takes time and can be damaging to the patient. Circulating cancer biomarkers such as circulating tumor DNA, micro-RNA (miRNA), tumor proteins, exosomes, and circulating tumor cells have repeatedly demonstrated their viability as targets for minimally invasive cancer detection through liquid biopsies. However, among other things, achieving a great sensitivity of detection is still challenging due to the very low concentration of biomarkers in fluid samples. This review will discuss how the recent advances in nanoparticle-based biosensors are overcoming these practical difficulties. This report will be focusing mainly on optical transduction mechanisms of metal nanoparticles (M-NPs), quantum dots (QDs), and upconversion nanoparticles (UCNPs).
Collapse
Affiliation(s)
- Chaima Amri
- Department of Convergence Medical Sciences, School of Medicine, Pusan National University, Yangsan 50612, Korea;
| | - Arvind Kumar Shukla
- School of Biomedical Convergence Engineering, Pusan National University, Yangsan 50612, Korea;
| | - Jin-Ho Lee
- Department of Convergence Medical Sciences, School of Medicine, Pusan National University, Yangsan 50612, Korea;
- School of Biomedical Convergence Engineering, Pusan National University, Yangsan 50612, Korea;
| |
Collapse
|
9
|
Electrochemical ultrasensitive detection of CYFRA21-1 using Ti 3C 2T x-MXene as enhancer and covalent organic frameworks as labels. Anal Bioanal Chem 2021; 413:2543-2551. [PMID: 33576855 DOI: 10.1007/s00216-021-03212-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 01/28/2021] [Accepted: 02/01/2021] [Indexed: 02/04/2023]
Abstract
The concentration level of cytokeratin fragment antigen 21-1 (CYFRA21-1) can be used as an important indicator for predicting non-small cell lung cancer (NSCLC). Here, a sandwich-type electrochemical immunosensor for ultrasensitive detection of CYFRA21-1 is developed. The sensor based on a combination of gold nanoparticle (AuNPs) decorated Ti3C2Tx-MXene (Au-Ti3C2Tx) as the substrate enhancer, and toluidine blue (TB) modified AuNPs doped covalent organic framework (COF) polymer as the signal tag (TB-Au-COF). The Au-Ti3C2Tx is used to capture numerous primary antibodies and accelerate the electron transfer rate of the substrate, while the TB-Au-COF can be applied to provide a large number of signal units TB and secondary antibodies. These features of composites endow the proposed immunosensor with high sensitivity and current response to CYFRA21-1. Under optimum conditions, the immunosensor offers a wide current response for CYFRA21-1 from 0.5-1.0 × 104 pg·mL-1 with a detection limit of 0.1 pg·mL-1. Furthermore, the biosensing platform can be applied for CYFRA21-1 detection to analyze real serum samples, providing an effective and useful avenue for the applicability of Au-Ti3C2Tx and TB-Au-COF composite materials in biosensing field.
Collapse
|
10
|
Wang M, Li J, Chen J, Zhang Y, Jia Y, Yang H, Kong J. Ultrasensitive electrochemical immunosensor via RAFT polymerization signal amplification for the detection of lung cancer biomarker. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114971] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
11
|
Abstract
Lung cancer is one of the serious malignant tumors with high morbidity and mortality due to the poor diagnosis and early metastasis. The developing nanotechnology provides novel concepts and research strategies for the lung cancer diagnosis by employing nanomaterials as diagnostic reagents to enhance diagnostic efficiency. This commentary introduces recent progress using nanoparticles for lung cancer diagnosis from two aspects of in vivo and in vitro detection. The challenges and future research perspectives are proposed at the end of the paper.
Collapse
|
12
|
Wu T, Feng J, Zhang S, Liu L, Ren X, Fan D, Kuang X, Sun X, Wei Q, Ju H. A self-powered photoanode-supported photoelectrochemical immunosensor for CYFRA 21-1 detection based on In2O3/In2S3/CdIn2S4 heterojunction. Biosens Bioelectron 2020; 169:112580. [DOI: 10.1016/j.bios.2020.112580] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 08/29/2020] [Accepted: 08/31/2020] [Indexed: 01/29/2023]
|
13
|
Fang L, Liao X, Jia B, Shi L, Kang L, Zhou L, Kong W. Recent progress in immunosensors for pesticides. Biosens Bioelectron 2020; 164:112255. [DOI: 10.1016/j.bios.2020.112255] [Citation(s) in RCA: 70] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 04/27/2020] [Accepted: 04/27/2020] [Indexed: 12/18/2022]
|
14
|
Fu Y, Ma Q. Recent developments in electrochemiluminescence nanosensors for cancer diagnosis applications. NANOSCALE 2020; 12:13879-13898. [PMID: 32578649 DOI: 10.1039/d0nr02844d] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In recent years, electrochemiluminescence (ECL) nanosensing systems have undergone rapid development and made significant progress in ultrasensitive analysis and cell imaging. Because of the unique advantages of high selectivity, ultra-sensitivity, and good reproducibility, ECL nanosensors can open new paths for cancer diagnosis. With the development of ECL nanosensors, high-throughput analysis, visual detection and spatially resolved ECL imaging of single cells are being realized. The innovations of ECL nanosensors consist of electrochemical excitation, coreactant catalysis, light radiation and luminescence signal amplification, which involve several fields such as nanotechnology, catalysis, optics, and electrochemistry. The developments of ECL instruments also relate to imaging technology. Herein, we review the construction modes, sensing strategies and cancer diagnosis applications of ECL nanosenors. Firstly, the nano-components of the ECL sensing system are discussed. The construction and signal amplification methods of the nanosensing system are emphasized. Secondly, the high-efficiency cancer identification strategies are presented, including protein tumor marker detection, nucleic acid assay, cancer cell identification and exosome detection. The recent advances in representative examples of ECL nanosenors in cancer diagnosis are highlighted, including high-throughput ECL analysis, in situ assay, visual ECL detection, single-cell imaging diagnosis, and so on. Finally, the challenges are featured based on the recent development of the ECL nanosensing system in the clinical diagnosis. The ECL nanosensors provide effective and reliable analytical methods and open new paths for cancer diagnosis. It is noteworthy that the prospects of the ECL nanosensing system in clinical diagnosis are instructive to the developments of other nanosensor research.
Collapse
Affiliation(s)
- Yantao Fu
- Department of thyroid surgery, China-Japan Union Hospital of Jilin University, Changchun, 130033, China
| | | |
Collapse
|