1
|
Sevgen S, Kara G, Kir AS, Şahin A, Boyaci E. A critical review of bioanalytical and clinical applications of solid phase microextraction. J Pharm Biomed Anal 2024; 252:116487. [PMID: 39378761 DOI: 10.1016/j.jpba.2024.116487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/07/2024] [Accepted: 09/26/2024] [Indexed: 10/10/2024]
Abstract
Studying the functions, mechanisms, and effects of drugs and other exogenous compounds on biological systems, together with investigations performed to understand biosystems better, comprises one of the most fascinating areas of research. Although classical sample preparation techniques are dominantly used to infer the relevant information from the investigated system, they fail to meet various imperative requirements, such as being environmentally friendly, applicable in-vivo, and compatible with online analysis. As a chameleon in the analytical toolbox, solid phase microextraction (SPME) is one of the best tools available for studying biological systems in unconventional ways. In this review, SPME is spotlighted, and its capability for bioanalytical applications, including drug analysis, untargeted and targeted metabolomics, in-vivo and clinical studies, is scrutinized based on studies reported in the past five years. In addition, novel extractive phases and instrumental coupling strategies developed to serve bioanalytical research are discussed to give the perspective for state-of-the-art and future developments. The literature assessment showed that SPME could act as a critical tool to investigate in-vivo biological systems and provide information about the elusive portion of the metabolome. Moreover, recently introduced miniaturized SPME probes further improved the low-invasive nature of the sampling and enabled sampling even from a single cell. The coupling of SPME directly to mass spectrometry significantly reduced the total analytical workflow and became one of the promising tools suitable for fast diagnostic purposes and drug analysis. The numerous applications and advancements reported in bioanalysis using SPME show that it will continue to be an indispensable technique in the future.
Collapse
Affiliation(s)
- Sılanur Sevgen
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Gökşin Kara
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Aysegul Seyma Kir
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Alper Şahin
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Ezel Boyaci
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye.
| |
Collapse
|
2
|
Bedair A, Abdelhameed RM, Hammad SF, Abdallah IA, Mansour FR. Applications of metal organic frameworks in dispersive micro solid phase extraction (D-μ-SPE). J Chromatogr A 2024; 1732:465192. [PMID: 39079363 DOI: 10.1016/j.chroma.2024.465192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 07/05/2024] [Accepted: 07/18/2024] [Indexed: 08/23/2024]
Abstract
Metal-organic frameworks (MOFs) are a fascinating family of crystalline porous materials made up of metal clusters and organic linkers. In comparison with other porous materials, MOFs have unique characteristics including high surface area, homogeneous open cavities, and permanent high porosity with variable shapes and sizes. For these reasons, MOFs have recently been explored as sorbents in sample preparation by solid-phase extraction (SPE). However, SPE requires large amounts of sorbents and suffers from limited contact surfaces with analytes, which compromises extraction recovery and efficiency. Dispersive SPE (D-SPE) overcomes these limitations by dispersing the sorbents into the sample, which in turn increases contact with the analytes. Miniaturization of the microextraction procedure, particularly the amount of sorbent reduces the amount consumed of the organic solvent and shorten the time required to attain the equilibrium state. This may explain the reported high efficiency and applicability of MOFs in dispersive micro SPE (D-µ-SPE). This method retains all the advantages of solid phase extraction while also being simpler, faster, cheaper, and, in some cases, more effective in comparison with D-SPE. Besides, D-µ-SPE requires smaller amounts of the sorbents which reduces the overall cost, and the amount of waste generated from the analytical process. In this review, we discuss the applications of MOFs in D-µ-SPE of various analytes including pharmaceuticals, pesticides, organic dyes from miscellaneous matrices including water samples, biological samples and food samples.
Collapse
Affiliation(s)
- Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897, Monufia, Egypt
| | - Reda M Abdelhameed
- Applied Organic Chemistry Department, Chemical Industries Research Institute, National Research Centre, Giza 12622, Egypt
| | - Sherin F Hammad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, 31111 Egypt
| | - Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897, Monufia, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, 31111 Egypt.
| |
Collapse
|
3
|
Leszczyńska D, Hallmann A, Treder N, Bączek T, Roszkowska A. Recent advances in the use of SPME for drug analysis in clinical, toxicological, and forensic medicine studies. Talanta 2024; 270:125613. [PMID: 38159351 DOI: 10.1016/j.talanta.2023.125613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/21/2023] [Accepted: 12/27/2023] [Indexed: 01/03/2024]
Abstract
Solid-phase microextraction (SPME) has gained attention as a simple, fast, and non-exhaustive extraction technique, as its unique features enable its use for the extraction of many classes of drugs from biological matrices. This sample-preparation approach consolidates sampling and sample preparation into a single step, in addition to providing analyte preconcentration and sample clean-up. These features have helped SPME become an integral part of several analytical protocols for monitoring drug concentrations in human matrices in clinical, toxicological, and forensic medicine studies. Over the years, researchers have continued to develop the SPME technique, resulting in the introduction of novel sorbents and geometries, which have resulted in improved extraction efficiencies. This review summarizes developments and applications of SPME published between 2016 and 2022, specifically in relation to the analysis of central nervous system drugs, drugs used to treat cardiovascular disorders and bacterial infections, and drugs used in immunosuppressive and anticancer therapies.
Collapse
Affiliation(s)
- Dagmara Leszczyńska
- Department of Pharmaceutical Biochemistry, Medical University of Gdańsk, Gdańsk, 80-211, Poland
| | - Anna Hallmann
- Department of Pharmaceutical Biochemistry, Medical University of Gdańsk, Gdańsk, 80-211, Poland
| | - Natalia Treder
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland.
| |
Collapse
|
4
|
Hasani F, Raoof JB, Ghani M, Ojani R. Nanoporous carbon fiber derived from Cu-BDC metal organic framework @pencil graphite as a sorbent for solid phase microextraction of acetamiprid and imidacloprid. Anal Chim Acta 2023; 1278:341650. [PMID: 37709423 DOI: 10.1016/j.aca.2023.341650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 07/14/2023] [Accepted: 07/15/2023] [Indexed: 09/16/2023]
Abstract
Solid-phase microextraction (SPME) is a sample pretreatment technique for enrichment of trace level of compounds from complex matrices. The fiber coating, as an extraction phase, is the significant part of SPME, which specifying the analytical performance of the developed SPME. In this study, a novel in situ fabricated Cu@porous carbon fiber that derived from copper benzene-1,4-dicarboxylate framework@pencil graphite (Cu-BDC MOF@PG) fiber was prepared as a SPME fiber. The Cu-BDC MOF was electrodeposited on the surface of pencil graphite. The Cu@porous carbon fiber with nanoporous structure was constructed by the direct carbonization of the electrosynthesized fiber. The Cu@porous carbon fiber showed high analytical performance for direct immersion SPME (DI-SPME) of acetamiprid and imidacloprid in fruit and vegetable samples. The SPME method was coupled by high-performance liquid chromatography-ultraviolet detection (SPME-HPLC-UV) for determination of the analytes. Under the optimized condition, good linear ranges (1-500 μg L-1 and 0.5-200 μg L-1) and acceptable limits of detection (LODs = 0.30 and 0.15 μg L-1), appropriate spiking recoveries in the range 87-109.0% were attained for acetamiprid and imidacloprid, respectively. Intra- and inter-day relative standard deviations were found within the ranges of 2.35-3.46% and 3.30-3.70%, respectively. These results signify promising potential of the in situ fabricated porous carbon fiber for SPME applications. Considering that most of the pencil graphite is made of carbon, after the carbonization of the Cu-BDC MOF@PG fiber, a unified porous carbon fiber is obtained. Compared to other reported procedures, in situ direct carbonization of Cu-BDC MOF@PG fiber was a one-step and straightforward method to fabricate carbon fiber.
Collapse
Affiliation(s)
- Fariba Hasani
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Milad Ghani
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Reza Ojani
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| |
Collapse
|
5
|
Determination of trimethoprim in milk, water and plasma using protein precipitation combined with liquid phase microextraction method. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2023.105224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
|
6
|
Hasani F, Raoof JB, Ghani M, Ojani R. In situ electrodeposition of Cu-BDC metal–organic framework on pencil graphite substrate for solid-phase microextraction of some pesticides. Mikrochim Acta 2022; 189:432. [DOI: 10.1007/s00604-022-05537-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 10/14/2022] [Indexed: 11/27/2022]
|
7
|
Urinary bio-monitoring of amphetamine derivatives by needle trap device packed with the zirconium-based metal-organic framework. Sci Rep 2022; 12:13702. [PMID: 35953701 PMCID: PMC9372183 DOI: 10.1038/s41598-022-17861-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 08/02/2022] [Indexed: 12/02/2022] Open
Abstract
In this research, zirconium-based metal–organic framework was utilized as a novel and efficient porous adsorbent for headspace extraction of Amphetamine, Methamphetamine, and Fenfluramine from the urine samples by a needle trap device (NTD). The Zr-UiO-66-PDC was electrosynthesized at the green conditions and characterized by various analyses such as FT-IR, XRD, FE-SEM, EDS, and elemental mapping techniques. Then, the effective parameters on the NTD efficiency such as salt content, pH, extraction/desorption temperature and time were evaluated and optimized by response surface methodology. The optimal extraction of amphetamine compounds was accomplished in 50 min at 70 ºC at the situation with NaCl content of 27% and pH: 11.90. The limit of detection, and limit of quantification factors were determined to be 0.06–0.09 and 0.5–0.8 ng mL−1, respectively. Furthermore, the precision and accuracy (intra- and inter-day) of the employed procedure in the term of relative standard deviation (RSD) were calculated in the range of 8.0–9.0% and 6.8–9.8%, respectively. Also, the recovery percent of the extracted analytes were concluded in the range of 95.0–97.0% after 10 days from the sampling and storage at 4 °C. Finally, the proposed procedure was involved in the analysis of amphetamine compounds in the real urine samples. These results were proved the proposed Zr-UiO-66-PDC@HS-NTD technique coupled with GC-FID can be used as an eco-friendly, fast-response, sensitive, and efficient drug test procedure for trace analysis of the amphetamine compounds in urine samples.
Collapse
|
8
|
Ren H, Tianxiang W. Electrochemical Synthesis Methods of Metal‐Organic Frameworks and Their Environmental Analysis Applications: A Review. ChemElectroChem 2022. [DOI: 10.1002/celc.202200196] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Hao Ren
- Nanjing Normal University School of Environment CHINA
| | - Wei Tianxiang
- Nanjing Normal University No. 1 Wenyuan Road, Qixia District Nanjing CHINA
| |
Collapse
|
9
|
Lian C, Feng X, Tian M, Tian Y, Zhang Y. Electrodeposition of zeolitic imidazolate framework coating on stainless steel wire for solid-phase microextraction of polycyclic aromatic hydrocarbons in water samples. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
10
|
Khodayari A, Sohrabnezhad S, Moinfar S, Pourahmad A. GNP/Al-MOF nanocomposite as an efficient fiber coating of headspace solid-phase micro-extraction for the determination of organophosphorus pesticides in food samples. Mikrochim Acta 2022; 189:45. [PMID: 34985689 DOI: 10.1007/s00604-021-05101-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 11/09/2021] [Indexed: 12/12/2022]
Abstract
The synthesis and utilization of a high porous nanocomposite comprising MIL-53(Al) metal-organic framework (Al-MOF) and graphene nanopowder (GNP) is reported as a fiber coating for headspace solid-phase micro-extraction (HS-SPME) of selected organophosphorus pesticides (OPPs) from apple, potato, grape juice, tomato, and river water. The adsorbed OPPs on the coated fiber were subsequently determined using GC-MS. Several parameters affecting the efficiency of extraction including time and temperature of extraction, desorption condition of extracted analytes, pH and agitation of sample solution, and salt concentration were investigated. The optimum extraction condition was achieved at 70 °C with an extraction time of 40 min, pH = 4-8, and NaCl concentration of 6.0% (w/v). The best condition of desorption were observed at 280 °C for 2.0 min under a flow of helium gas in the GC inlet. Under optimal conditions, the detection limits ranged from 0.2 to 1.5 ng g-1 and the linear ranges between 0.8 and 600 ng g-1. The proposed method showed very good repeatability with RSD values ranging from 4.5 to 7.3% (n = 5). The relative recoveries were between 88% and 109% at the spiked level of 25.0 ng g-1 for the tomato sample. The fabricated fiber exhibited good enrichment factor (62-195) at optimum condition of HS-SPME. The applied HS-SPME technique is facile, fast, and inexpensive. The thermally stable GNP/Al-MOF exhibited a high sensitivity toward OPPs. So, this nanocomposite can be considered as a sorbent for the micro-extraction of other pesticides in food.
Collapse
Affiliation(s)
- Ali Khodayari
- Department of Chemistry, Faculty of Science, University of Guilan, P.O. Box 1914, Rasht, Iran
| | - Shabnam Sohrabnezhad
- Department of Chemistry, Faculty of Science, University of Guilan, P.O. Box 1914, Rasht, Iran.
| | | | - Afshin Pourahmad
- Department of Chemistry, Rasht Branch, Islamic Azad University, Rasht, Iran
| |
Collapse
|
11
|
Point-of-care testing of methylamphetamine with a portable optical fiber immunosensor. Anal Chim Acta 2021; 1192:339345. [DOI: 10.1016/j.aca.2021.339345] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 11/24/2021] [Accepted: 11/30/2021] [Indexed: 12/23/2022]
|
12
|
Uflyand IE, Zhinzhilo VA, Bryantseva JD. Synthesis and Study of Sorption, Antioxidant and Antibacterial Properties of MOF based on Cobalt Terephthalate and 1,10-Phenanthroline. J Inorg Organomet Polym Mater 2021. [DOI: 10.1007/s10904-021-02087-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
13
|
Peng S, Huang X, Huang Y, Huang Y, Zheng J, Zhu F, Xu J, Ouyang G. Novel solid-phase microextraction fiber coatings: A review. J Sep Sci 2021; 45:282-304. [PMID: 34799963 DOI: 10.1002/jssc.202100634] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 11/13/2021] [Accepted: 11/15/2021] [Indexed: 12/27/2022]
Abstract
The materials used for the fabrication of solid-phase microextraction fiber coatings in the past five years are summarized in the current review, including carbon, metal-organic frameworks, covalent organic frameworks, aerogel, polymer, ionic liquids/poly (ionic liquids), metal oxides, and natural materials. The preparation approaches of different coatings, such as sol-gel technique, in-situ growth, electrodeposition, and glue methods, are briefly reviewed together with the evolution of the supporting substrates. In addition, the limitations of the current coatings and the future development directions of solid-phase microextraction are presented.
Collapse
Affiliation(s)
- Sheng Peng
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Xiaoyu Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Yuyan Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Yiquan Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Juan Zheng
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| |
Collapse
|
14
|
Green synthesis and properties of nickel terephthalate complex with 2,2'-bipyridine. MENDELEEV COMMUNICATIONS 2021. [DOI: 10.1016/j.mencom.2021.11.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Metal organic framework derived Zn/N co-doped hydrophilic porous carbon for efficient solid phase microextraction of polar phenols. Mikrochim Acta 2021; 188:400. [PMID: 34718874 DOI: 10.1007/s00604-021-05060-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 10/11/2021] [Indexed: 10/19/2022]
Abstract
MOF-derived zink and nitrogen co-doped porous carbon (ZNPC) was synthesized through the pyrolysis of MOF-5-NH2 and used as a solid-phase microextraction (SPME) coating material. Coupled with gas chromatography-mass spectrometry (GC-MS), headspace SPME (HS-SPME) based on ZNPC was adopted for the determination of phenols in food samples. The co-existence of N and Zn in ZNPC endows the derived carbon superior hydrophilicity, which is highly beneficial for phenols capture. After optimizing the conditions of extraction and desorption, a sensitive analytical method was established with low limits of detections (LODs, 0.73-2.3 ng g-1) and wide linear ranges (5-5000 ng g-1). Both the intra-fiber repeatability (RSDs from 2.8-7.3%) and inter-fiber reproducibility (RSDs from 9.7-11.7%) were satisfactory. The established method was applied to phenol determination in beef jerky and duck neck with satisfactory recoveries of 81.2-120.4% and RSDs of 2.8-9.9%, which met well with the requirement of practical application.
Collapse
|
16
|
Bazargan M, Ghaemi F, Amiri A, Mirzaei M. Metal–organic framework-based sorbents in analytical sample preparation. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214107] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
17
|
Uflyand IE, Zhinzhilo VA, Nikolaevskaya VO, Kharisov BI, González CMO, Kharissova OV. Recent strategies to improve MOF performance in solid phase extraction of organic dyes. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106387] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
18
|
Moinfar S, Khodayari A, Abdulrahman SS, Aghaei A, Sohrabnezhad S, Jamil LA. Development of a SPE/GC-MS method for the determination of organophosphorus pesticides in food samples using syringe filters packed by GNP/MIL-101(Cr) nanocomposite. Food Chem 2021; 371:130997. [PMID: 34537611 DOI: 10.1016/j.foodchem.2021.130997] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 08/06/2021] [Accepted: 08/29/2021] [Indexed: 02/06/2023]
Abstract
In this study, we report the synthesis and application of a nanocomposite comprising metal-organic framework MIL-101(Cr) and graphene nanopowder (GNP) as a promising sorbent for the extraction of organophosphorus pesticides (OPPs) in juices, water, vegetables and honey samples. A syringe filter, for the first time, was used to host the synthesized nanocomposite and extract the OPPs followed by GC-MS analysis. Different characterization methods including XRD, FTIR, TGA, BET and SEM were employed to confirm the formation of studied nanocomposite. The results indicated that the GNP/MIL-101(Cr) could provide higher capacity for adsorption of OPPs and lower detection limit compared to pristine MIL-101(Cr). The detection limits were 0.005 to 15.0 µg/Kg and the linear range found between 0.05 and 400 µg/Kg. The proposed method showed very good repeatability with the RSD values ranging from 2.9% to 7.1%. The recoveries were between 84% -110% with the spiked levels of 2.0-100.0 µg/Kg.
Collapse
Affiliation(s)
| | - Ali Khodayari
- Department of Chemistry, Faculty of Science, University of Guilan, P.O. Box 1914, Rasht, Iran; Department of Chemistry, Faculty of Science, University of Mohaghegh Ardabili, 56199-11367 Ardabil, Iran
| | | | - Ali Aghaei
- Department of Chemistry, Faculty of Science, University of Zakho, Zakho, Iraq
| | - Shabnam Sohrabnezhad
- Department of Chemistry, Faculty of Science, University of Guilan, P.O. Box 1914, Rasht, Iran
| | - Lazgin Abdi Jamil
- Department of Chemistry, Faculty of Science, University of Zakho, Zakho, Iraq
| |
Collapse
|
19
|
A hybrid nano-MOF/polymer material for trace analysis of fluoroquinolones in complex matrices at microscale by on-line solid-phase extraction capillary electrophoresis. Talanta 2021; 233:122529. [PMID: 34215032 DOI: 10.1016/j.talanta.2021.122529] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 05/11/2021] [Accepted: 05/12/2021] [Indexed: 12/15/2022]
Abstract
A hybrid material (nano-metal organic framework@organic polymer, named as nano-MOF@polymer) was applied for the first time as sorbent for on-line solid-phase extraction capillary electrophoresis with ultraviolet detection (SPE-CE-UV). The resulting material was prepared building layer-by-layer a HKUST-1 (Hong Kong University of Science and Technology-1) nano-MOF onto the polymer surface, which allowed controlling the thickness and maximizing the active surface area. The sorbent was widely characterized at micro- and nano-scale to validate the synthesis and to establish the material properties. Then, fritless microcartridges (2 mm) were assembled by packing only a few micrograms of sorbent particles and investigated for preconcentration of fluoroquinolones (FQs) in several real samples (river water, human urine and whole cow milk). Under the optimized conditions, the sample (ca. 60 μL) was loaded in separation background electrolyte (BGE, 50 mM phosphate (pH 7)), and retained analytes were eluted using a small volume of 2% v/v formic acid in methanol (ca. 50 nL). The SPE-CE-UV method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), repeatability, reproducibility and reusability. The developed method showed a LOD decreasing until 1 ng L-1 when larger volumes of sample were loaded (ca. 180 μL), which was 500,000 times lower than by CE-UV. This undescribed sensitivity enhancement would arise from the homogenous and populated MOF nano-domains and the appropriate permeability of the hybrid material, which would promote high extraction efficiency and loading capacity. Furthermore, the sorbent showed appropriate selectivity regardless the analyzed complex environmental, biological or food matrix samples, achieving excellent detectability and recoveries (>90%).
Collapse
|
20
|
Liu X, Hu Q, Tong Y, Li N, Ouyang S, Yang H, Xu J, Ouyang G. Sample bottle coated with sorbent as a novel solid-phase extraction device for rapid on-site detection of BTEX in water. Anal Chim Acta 2021; 1152:338226. [PMID: 33648643 DOI: 10.1016/j.aca.2021.338226] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/15/2021] [Accepted: 01/16/2021] [Indexed: 11/27/2022]
Abstract
Solid-phase extraction (SPE) is a popular technique for environmental sample pretreatment. However, SPE usually requires complex sample pretreatment processes, which is time-consuming and inconvenient for real-time and on-site monitoring. Herein, a solvent-free, rapid, and user-friendly SPE device was developed by coating the polydimethylsiloxane (PDMS)/divinylbenzene (DVB) sorbent on the inner wall of a sample bottle. The extraction process and desorption process were both carried out in the bottle. The analytes trapped in the sorbent were thermally desorbed and simultaneously sucked out from the bottle by an air sampling tube equipped on field-portable GC-MS. Different to previous work, the sample pretreatment process didn't require any complicated and time-consuming steps, such as centrifugation or filtration. The total analysis time for each sample was less than 25 min, which was feasible for rapid on-site detection, and thus avoided the losses and contamination of samples in conventional sample storage and transportation processes. Under optimal conditions, the proposed SPE method exhibited wide linear ranges, low detection limits (0.010-0.036 μg L-1, which were much lower than the maximum levels restricted by the US Environmental Protection Agency and the Chinese GB3838-2002 standard), good intra-bottle repeatability (6.13-7.17%, n = 3) and satisfactory inter-bottle reproducibility (4.73-6.47%, n = 3). Finally, the method was successfully applied to the rapid detection of BTEX in the field. The recoveries of BTEX in spiked water samples ranged from 89.1% to 116.2%. This work presents a novel SPE approach for rapid on-site monitoring in water samples.
Collapse
Affiliation(s)
- Xiwen Liu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China
| | - Qingkun Hu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China
| | - Yuanjun Tong
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China
| | - Nan Li
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China
| | - Sai Ouyang
- Key Laboratory of Hunan Province for Advanced Carbon-based Functional Materials, School of Chemistry and Chemical Engineering, Hunan Institute of Science and Technology, Yueyang, 414006, Hunan, PR China
| | - Huangsheng Yang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China.
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, China
| |
Collapse
|
21
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
22
|
Moinfar S, Khodayari A, Sohrabnezhad S, Aghaei A, Jamil LA. MIL-53(Al)/Fe2O3 nanocomposite for solid-phase microextraction of organophosphorus pesticides followed by GC-MS analysis. Mikrochim Acta 2020; 187:647. [DOI: 10.1007/s00604-020-04621-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 10/21/2020] [Indexed: 12/24/2022]
|