1
|
Sun Q, Zhu W, Shi E, Bai M, Liu Z, Yang Z. Nanoquantification of RUNX2 by a 1,1'-carbonyldiimidazole-diamond mediated sandwich assay for osteogenic differentiation. Heliyon 2024; 10:e31837. [PMID: 38868000 PMCID: PMC11167296 DOI: 10.1016/j.heliyon.2024.e31837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 03/29/2024] [Accepted: 05/22/2024] [Indexed: 06/14/2024] Open
Abstract
Adipose tissue-derived stem cells (ADSCs) possess the capability to modulate the immune response and alleviate inflammation, rendering them a promising therapeutic option for various conditions, including autoimmune diseases, cardiovascular diseases, and tissue injuries. The osteogenic differentiation in ADSCs plays a pivotal role in fracture healing, bone growth, and the overall bone turnover process, governed by intricate interactions. Runt-related Transcription Factor 2 (RUNX2) is a key player in mineralized tissue generation and is typically found in the early stages of osteogenic differentiation. The objective of this study was to develop a high-affinity sandwich biosensor for the quantification of RUNX2. 1,1'-Carbonyldiimidazole-modified nanodiamond was immobilized on an amine-modified interdigitated electrode surface, followed by the use of a capture antibody to facilitate antigen interaction. A sandwich assay was conducted with the antibody, and the limit of detection for RUNX2 was calculated as 0.1 ng/mL, with a regression value (R2) of 0.9914 over a linear range of 1-2000 ng/mL. Furthermore, biofouling experiments with a nonimmune antibody, BSA, and TNF-α did not yield any current responses, indicating the specific detection of RUNX2. Additionally, RUNX2-spiked serum exhibited an increasing current response at all concentrations, confirming the selective detection of RUNX2.
Collapse
Affiliation(s)
- Qingshan Sun
- Department of Bone Surgery, The Third Hospital of Shandong Province, Jinan, Shandong, 250031, China
| | - Wei Zhu
- Department of Orthopaedics, Changshu Zhitang People's Hospital, Changshu, Jiangsu, 215531, China
| | - Endong Shi
- Department of Bone Surgery, The Third Hospital of Shandong Province, Jinan, Shandong, 250031, China
| | - Maheng Bai
- Department of Second Orthopedics (Department of Joint Surgery), The Xingyuan Hospital of Yulin (The fourth of Yulin Hospital), Yulin, Shaanxi, 719000, China
| | - ZengIiang Liu
- Department of Second Orthopedics (Department of Joint Surgery), The Xingyuan Hospital of Yulin (The fourth of Yulin Hospital), Yulin, Shaanxi, 719000, China
| | - Zhiquan Yang
- Department of Second Orthopedics (Department of Joint Surgery), The Xingyuan Hospital of Yulin (The fourth of Yulin Hospital), Yulin, Shaanxi, 719000, China
| |
Collapse
|
2
|
Tasić N, Konjević I, Lobato A, Metarapi D, Finšgar M, Oliveira FM, Sofer Z, Gusmão R, Zhang X, Hočevar SB. Study of V 2CT x-MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein. ACS APPLIED MATERIALS & INTERFACES 2024; 16:30196-30208. [PMID: 38814245 PMCID: PMC11181268 DOI: 10.1021/acsami.4c04567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 05/13/2024] [Accepted: 05/15/2024] [Indexed: 05/31/2024]
Abstract
Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.
Collapse
Affiliation(s)
- Nikola Tasić
- Department
of Analytical Chemistry, National Institute
of Chemistry, Hajdrihova ulica 19, 1000 Ljubljana, Slovenia
| | - Ivan Konjević
- Department
of Analytical Chemistry, National Institute
of Chemistry, Hajdrihova ulica 19, 1000 Ljubljana, Slovenia
- Faculty
of Chemistry and Chemical Technology, University
of Ljubljana, Večna
pot 113, 1000 Ljubljana, Slovenia
| | - Alnilan Lobato
- Department
of Analytical Chemistry, National Institute
of Chemistry, Hajdrihova ulica 19, 1000 Ljubljana, Slovenia
- International
Postgraduate School Jožef Štefan, Jamova 39, 1000 Ljubljana, Slovenia
| | - Dino Metarapi
- Department
of Analytical Chemistry, National Institute
of Chemistry, Hajdrihova ulica 19, 1000 Ljubljana, Slovenia
| | - Matjaž Finšgar
- Faculty
of Chemistry and Chemical Engineering, University
of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
| | - Filipa M. Oliveira
- Department
of Inorganic Chemistry, University of Chemistry
and Technology Prague, Technická 5, 166 28 Praha 6-Dejvice, Czech Republic
| | - Zděnek Sofer
- Department
of Inorganic Chemistry, University of Chemistry
and Technology Prague, Technická 5, 166 28 Praha 6-Dejvice, Czech Republic
| | - Rui Gusmão
- Department
of Inorganic Chemistry, University of Chemistry
and Technology Prague, Technická 5, 166 28 Praha 6-Dejvice, Czech Republic
| | - Xueji Zhang
- School
of
Biomedical Engineering, Shenzhen University
Health Science Center, 3688 Nanhai Road, Nanshan District, Shenzhen 518054, Guangdong P.R. China
| | - Samo B. Hočevar
- Department
of Analytical Chemistry, National Institute
of Chemistry, Hajdrihova ulica 19, 1000 Ljubljana, Slovenia
| |
Collapse
|
3
|
Kim YJ, Min J. Advances in nanobiosensors during the COVID-19 pandemic and future perspectives for the post-COVID era. NANO CONVERGENCE 2024; 11:3. [PMID: 38206526 PMCID: PMC10784265 DOI: 10.1186/s40580-023-00410-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 12/07/2023] [Indexed: 01/12/2024]
Abstract
The unprecedented threat of the highly contagious virus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes exponentially increased infections of coronavirus disease 2019 (COVID-19), highlights the weak spots of the current diagnostic toolbox. In the midst of catastrophe, nanobiosensors offer a new opportunity as an alternative tool to fill a gap among molecular tests, rapid antigen tests, and serological tests. Nanobiosensors surpass the potential of antigen tests because of their enhanced sensitivity, thus enabling us to see antigens as stable and easy-to-access targets. During the first three years of the COVID-19 pandemic, a substantial number of studies have reported nanobiosensors for the detection of SARS-CoV-2 antigens. The number of articles on nanobiosensors and SARS-CoV-2 exceeds the amount of nanobiosensor research on detecting previous infectious diseases, from influenza to SARS-CoV and MERS-CoV. This unprecedented publishing pace also implies the significance of SARS-CoV-2 and the present pandemic. In this review, 158 studies reporting nanobiosensors for detecting SARS-CoV-2 antigens are collected to discuss the current challenges of nanobiosensors using the criteria of point-of-care (POC) diagnostics along with COVID-specific issues. These advances and lessons during the pandemic pave the way for preparing for the post-COVID era and potential upcoming infectious diseases.
Collapse
Affiliation(s)
- Young Jun Kim
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea
| | - Junhong Min
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea.
| |
Collapse
|
4
|
Gopinath SCB, Ramanathan S, More M, Patil K, Patil SJ, Patil N, Mahajan M, Madhavi V. A Review on Graphene Analytical Sensors for Biomarker-based Detection of Cancer. Curr Med Chem 2024; 31:1464-1484. [PMID: 37702170 DOI: 10.2174/0929867331666230912101634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 05/01/2023] [Accepted: 06/22/2023] [Indexed: 09/14/2023]
Abstract
The engineering of nanoscale materials has broadened the scope of nanotechnology in a restricted functional system. Today, significant priority is given to immediate health diagnosis and monitoring tools for point-of-care testing and patient care. Graphene, as a one-atom carbon compound, has the potential to detect cancer biomarkers and its derivatives. The atom-wide graphene layer specialises in physicochemical characteristics, such as improved electrical and thermal conductivity, optical transparency, and increased chemical and mechanical strength, thus making it the best material for cancer biomarker detection. The outstanding mechanical, electrical, electrochemical, and optical properties of two-dimensional graphene can fulfil the scientific goal of any biosensor development, which is to develop a more compact and portable point-of-care device for quick and early cancer diagnosis. The bio-functionalisation of recognised biomarkers can be improved by oxygenated graphene layers and their composites. The significance of graphene that gleans its missing data for its high expertise to be evaluated, including the variety in surface modification and analytical reports. This review provides critical insights into graphene to inspire research that would address the current and remaining hurdles in cancer diagnosis.
Collapse
Affiliation(s)
- Subash Chandra Bose Gopinath
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000 Kangar, Perlis, Malaysia
- Micro System Technology, Centre of Excellence (CoE), Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia
| | - Santheraleka Ramanathan
- Department of Biomedical Engineering and Health Sciences, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia
| | - Mahesh More
- Department of Pharmaceutics, Sanjivani College of Pharmaceutical Education and Research, Kopargaon, India
| | - Ketan Patil
- Department of Pharmaceutics, Ahinsa Institute of Pharmacy, Dondaicha, India
| | | | - Narendra Patil
- Department of Pharmacology, Dr. A.P.J. Abdul Kalam University, Indore, India
| | - Mahendra Mahajan
- Department of Pharmaceutical Chemistry, H.R. Patel Institute of Pharmacy, Shirpur, India
| | - Vemula Madhavi
- BVRIT Hyderabad college of Engineering for Women, Hyderabad, India
| |
Collapse
|
5
|
Zhao L, Wu L, Xu W, Wei J, Niu X, Liu G, Yu L, Wu Y, Zhou Q, Liu L. Diagnostic techniques for critical respiratory infections: Update on current methods. Heliyon 2023; 9:e18957. [PMID: 37600408 PMCID: PMC10432708 DOI: 10.1016/j.heliyon.2023.e18957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 07/26/2023] [Accepted: 08/03/2023] [Indexed: 08/22/2023] Open
Abstract
Respiratory infections, whether chronic or acute, are frequent in both children and adults and result in an economic burden in health care systems. In particular, for an immunocompromised patient, respiratory infection leads to acute hypoxemic respiratory failure, a leading cause of intensive care unit (ICU) admission. Most respiratory infections are caused by bacteria, viruses, parasites, smoking, or air pollution. Over the last two decades, considerable improvements have been made in understanding and identifying respiratory infections. Various biosensing techniques have been developed with a range of targets to identify the infection at earlier stages. Recently, nanomaterials have been effectively applied to improve biosensors and their analytical performances. This review discusses recent biosensor developments for identifying respiratory infections caused by viruses and bacteria assisted by different types of nanomaterials and target molecules.
Collapse
Affiliation(s)
| | | | | | - Jing Wei
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| | - Xiaorong Niu
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| | - GuoYin Liu
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| | - Li Yu
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| | - Ying Wu
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| | - Qiang Zhou
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| | - Lu Liu
- Chaoyang District of the Third Hospital, 1268 Jiuzhou Street, Xihu District, Nanchang City, Jiangxi Province, China
| |
Collapse
|
6
|
Yadav S, Sadique MA, Ranjan P, Khan R. Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19. Anal Chim Acta 2023; 1265:341326. [PMID: 37230571 DOI: 10.1016/j.aca.2023.341326] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.
Collapse
Affiliation(s)
- Shalu Yadav
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India
| | - Mohd Abubakar Sadique
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India
| | - Pushpesh Ranjan
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India
| | - Raju Khan
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India.
| |
Collapse
|
7
|
Xie X, Liu D, Wang W, Xiang J, Yang M, Liu G. Microelectrode-Based Electrochemical Impedance Determination of Brain-Derived Neurotrophic Factor in Aqueous Humor for Diagnosis of Glaucoma. Anal Chem 2023; 95:2087-2093. [PMID: 36628978 DOI: 10.1021/acs.analchem.2c05033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The abundance of brain-derived neurotrophic factor (BDNF) in aqueous humor (AH) is an ideal biomarker for the diagnosis of glaucoma, a chronic progressive optic neuropathy and the most frequent cause of irreversible blindness. The difficulty of AH-based BDNF detection is from the small amount of extracted AH in a paracentesis (<100 μL) and the ultra-low abundance of BDNF. In this work, we systematically studied the non-specific adsorption of biofluids on the bare gold electrode by electrochemistry and Raman spectroscopy techniques, revealing the unexpected negative correlation of the extent of non-specific adsorption with the size of the electrode. Based on it, a simple microelectrode-based sensor without the introduction of the blocking layer was developed for the detection of BDNF in the AH sample. Using electrochemical impedance spectroscopy (EIS) and extracting the changes of electron-transfer resistance of the electrochemical probe [Fe(CN)6]3-/4- on the sensor surface, the BDNF was quantified. The dynamic range was from 0.5 to 50 pg·mL-1, with a detection limit of 0.3 pg·mL-1 and a sample consumption of 5 μL. The real AH sample analysis confirmed the significant decrease of BDNF abundance in the AH of glaucoma patients. Our microelectrode-based EIS sensor displayed prominent advantages on simplified preparation, sensitive response, and low sample consumption. This AH-based BDNF analysis is expected to be used for the screening and diagnosis of glaucoma, especially for the high-risk population who have ocular diseases and have to undergo surgeries.
Collapse
Affiliation(s)
- Xin Xie
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha410083, P. R. China
- National Engineering Research Center of Personalized Diagnostic and Therapeutic Technology, Central South University, Changsha410083, P. R. China
| | - Dan Liu
- Eye Center of Xiangya Hospital, Central South University, Changsha410083, P. R. China
| | - Weili Wang
- State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen361102, China
| | - Juan Xiang
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha410083, P. R. China
- National Engineering Research Center of Personalized Diagnostic and Therapeutic Technology, Central South University, Changsha410083, P. R. China
| | - Minghui Yang
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha410083, P. R. China
| | - Guokun Liu
- State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen361102, China
| |
Collapse
|
8
|
Fadhilah GN, Yusuf M, Sari AK, Tohari TR, Wiraswati HL, Ekawardhani S, Faridah L, Fauziah N, Anshori I, Wahyuni Hartati Y. An scFv‐Based Impedimetric Immunosensor Using SPCE/AuNP for RBD of SARS‐CoV‐2 Detection. ChemistrySelect 2023. [DOI: 10.1002/slct.202203928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Ghina Nur Fadhilah
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
| | - Muhammad Yusuf
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
- Molecular Biotechnology and Bioinformatics Research Center Universitas Padjadjaran Indonesia
| | - Arum Kurnia Sari
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
| | - Taufik Ramdani Tohari
- Molecular Biotechnology and Bioinformatics Research Center Universitas Padjadjaran Indonesia
| | - Hesti Lina Wiraswati
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Savira Ekawardhani
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Lia Faridah
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Nisa Fauziah
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Isa Anshori
- Lab-on-Chip Group Bandung Institute of Technology Indonesia
| | - Yeni Wahyuni Hartati
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
- Molecular Biotechnology and Bioinformatics Research Center Universitas Padjadjaran Indonesia
| |
Collapse
|
9
|
Gopinath SCB, Ramanathan S, Chinni SV, Dorairaj V, Lakshmipriya T. Non-protein coding RNA sequences mediate specific colorimetric detection of Staphylococcus aureus on unmodified gold nanoparticles. Sci Rep 2022; 12:12621. [PMID: 35871246 PMCID: PMC9308785 DOI: 10.1038/s41598-022-16551-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Accepted: 07/12/2022] [Indexed: 11/29/2022] Open
Abstract
Nonprotein coding RNA (npcRNA) is a transcribed gene sequence that is not able to translate into protein, yet it executes a specific function in modulation and regulation mechanisms. As npcRNA is highly resistant to the mutation, the Sau-02 npcRNA gene and its probe oligonucleotide, which are specifically present in Staphylococcus aureus and in methicillin-resistant S. aureus only, used to develop a highly specific and sensitive colorimetric assay on unmodified gold nanoparticles (AuNPs). Hybridization between the npcRNA Sau-02 gene sequences was detected through noncrosslinking AuNP aggregation in salt solution in the presence of probe-target gene sequences. AuNPs of 10 and 15 nm in sizes with monovalent ion salt (NaCl) solution were optimized as the ideal tool for investigating the stability of AuNPs upon the addition of gene sequences. The state dispersed and aggregated forms of 10 nm AuNPs with the presented colorimetric assay were justified through field emission scanning electron microscopy and atomic force microscopy. The particle distribution of two different AuNP states was evaluated through particle distribution analysis. The lowest detection amount of S. aureus npcRNA from the colorimetric assay performed was 6 pg/µL, as the color of AuNPs turned blue with the presence of probe oligonucleotides and target gene sequences.
Collapse
|
10
|
Sadique MA, Yadav S, Khare V, Khan R, Tripathi GK, Khare PS. Functionalized Titanium Dioxide Nanoparticle-Based Electrochemical Immunosensor for Detection of SARS-CoV-2 Antibody. Diagnostics (Basel) 2022; 12:2612. [PMID: 36359457 PMCID: PMC9689474 DOI: 10.3390/diagnostics12112612] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/22/2022] [Accepted: 10/24/2022] [Indexed: 12/05/2023] Open
Abstract
The advancement in biosensors can overcome the challenges faced by conventional diagnostic techniques for the detection of the highly infectious severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Hence, the development of an accurate, rapid, sensitive, and selective diagnostic technique can mitigate adverse health conditions caused by SARS-CoV-2. This work proposes the development of an electrochemical immunosensor based on bio-nanocomposites for the sensitive detection of SARS-CoV-2 antibodies through the differential pulse voltammetry (DPV) electroanalytical method. The facile synthesis of chitosan-functionalized titanium dioxide nanoparticles (TiO2-CS bio-nanocomposites) is performed using the sol-gel method. Characterization of the TiO2-CS bio-nanocomposite is accomplished using UV-vis spectroscopy, Raman spectroscopy, X-ray diffraction (XRD), and transmission electron microscopy (TEM). The electrochemical performance is studied using cyclic voltammetry (CV), DPV, and electrochemical impedance spectroscopy (EIS) for its electroanalytical and biosensing capabilities. The developed immunosensing platform has a high sensitivity with a wide range of detection from 50 ag mL-1 to 1 ng mL-1. The detection limit of the SARS-CoV-2 antibody in buffer media is obtained to be 3.42 ag mL-1 and the limit of quantitation (LOQ) to be 10.38 ag mL-1. The electrochemical immunosensor has high selectivity in different interfering analytes and is stable for 10 days. The results suggest that the developed electrochemical immunosensor can be applicable for real sample analysis and further high-throughput testing.
Collapse
Affiliation(s)
- Mohd Abubakar Sadique
- Industrial Waste Utilization, Nano and Biomaterials, CSIR-Advanced Materials and Processes Research Institute (AMPRI), Bhopal 462026, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Shalu Yadav
- Industrial Waste Utilization, Nano and Biomaterials, CSIR-Advanced Materials and Processes Research Institute (AMPRI), Bhopal 462026, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Vedika Khare
- School of Nanotechnology, Rajiv Gandhi Proudyogiki Vishwavidyalaya, Bhopal 462033, India
| | - Raju Khan
- Industrial Waste Utilization, Nano and Biomaterials, CSIR-Advanced Materials and Processes Research Institute (AMPRI), Bhopal 462026, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Gagan Kant Tripathi
- School of Nanotechnology, Rajiv Gandhi Proudyogiki Vishwavidyalaya, Bhopal 462033, India
| | - Purnima Swarup Khare
- School of Nanotechnology, Rajiv Gandhi Proudyogiki Vishwavidyalaya, Bhopal 462033, India
| |
Collapse
|
11
|
Mao S, Fu L, Yin C, Liu X, Karimi-Maleh H. The role of electrochemical biosensors in SARS-CoV-2 detection: a bibliometrics-based analysis and review. RSC Adv 2022; 12:22592-22607. [PMID: 36105989 PMCID: PMC9372877 DOI: 10.1039/d2ra04162f] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 08/03/2022] [Indexed: 12/16/2022] Open
Abstract
The global pandemic of COVID-19, which began in late 2019, has resulted in extremely high morbidity and severe mortality worldwide, with important implications for human health, international trade, and national politics. Severe acute respiratory syndrome coronavirus (SARS-CoV-2) is the primary pathogen causing COVID-19. Analytical chemistry played an important role in this global epidemic event, and detection of SARS-CoV-2 even became a part of daily life. Analytical chemists have devoted much effort and enthusiasm to this event, and different analytical techniques have shown very rapid development. Electrochemical biosensors are highly efficient, sensitive, and cost-effective and have been used to detect many highly pathogenic viruses long before this event. However, another fact is that electrochemical biosensors are not the technology of choice for most detection applications. This review describes for the first time the role played by electrochemical biosensors in SARS-CoV-2 detection from a bibliometric perspective. This paper analyzed 254 relevant research papers up to June 2022. The contributions of different countries and institutions to this topic were analyzed. Keyword analysis was used to explore different methodological attempts of electrochemical detection techniques. More importantly, we are trying to find an answer to the question: do electrochemical biosensors have the potential to become a genuinely employable detection technology in an outbreak of infectious disease? This review describes for the first time the role played by electrochemical biosensors in SARS-CoV-2 detection from a bibliometric perspective.![]()
Collapse
Affiliation(s)
- Shudan Mao
- Key Laboratory of Pollution Exposure and Health Intervention of Zhejiang Province, Interdisciplinary Research Academy, Zhejiang Shuren University, Hangzhou 310021, PR China
| | - Li Fu
- Key Laboratory of Novel Materials for Sensor of Zhejiang Province, College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Chengliang Yin
- National Engineering Laboratory for Medical Big Data Application Technology, Chinese PLA General Hospital, Beijing, China
- Medical Big Data Research Center, Medical Innovation Research Division of PLA General Hospital, Beijing, China
| | - Xiaozhu Liu
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, China
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, Xiyuan Ave, 611731, Chengdu, China
- Department of Chemical Engineering, Quchan University of Technology, Quchan 9477177870, Iran
- Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, 2028, Johannesburg 17011, South Africa
| |
Collapse
|