1
|
Song X, Peng M, Luo Q, Huang X. Task specific microextraction column based on monolith for magnetic field-assisted in-tube solid phase microextraction of vanadium species in complex samples prior to online chromatographic analysis. Talanta 2024; 270:125528. [PMID: 38118323 DOI: 10.1016/j.talanta.2023.125528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 11/26/2023] [Accepted: 12/05/2023] [Indexed: 12/22/2023]
Abstract
The dominant species of vanadium (V) are V(IV) and V(V) which exhibit different toxicity and biological effects. Thus, speciation of V(IV) and V(V) is highly essential. Efficient sample preparation is the core step in the quantification of V(IV) and V(V). In the present study, a new task specific microextraction column based on monolith mingled with Fe3O4 nanoparticles (MBMC) was in situ synthesized in capillary and utilized as the extraction phase of magnetic field-assisted in-tube solid phase microextraction (MA-IT-SPME) of V(IV) and V(V) species which were coordinated with ethylene diamine tetraacetic acid (EDTA). The prepared MBMC presented porous and superparamagnetic properties, and possessed abundant functional groups. Results revealed that the exertion of magnetic field during adsorption and eluting steps boosted the extraction efficiency of V(IV)-EDTA and V(V)-EDTA chelates from 65.1 % to 55.7 %-90.0 % and 80.1 %, respectively. Under the beneficial extraction parameters, the established MA-IT-SPME was online hyphenated with HPLC/DAD to perform speciation of trace vanadium in water and vegetable samples, the achieved limits of detection were 0.054-0.060 μg/L and 1.4-1.5 μg/kg in water and vegetable samples, respectively, and the spiked recoveries varied from 82.5 to 118 %. In addition, relevant extraction mechanism under magnetic field was explored. In comparison with existing methods, the developed MA-IT-SPME technique displays some attractive merits such as automation, good anti-interference ability, high extraction efficiency, low cost and less use of organic solvent, in the capture of V species. The established online MBMC@MA-IT-SPME-HPLC/DAD system can become a competitive approach for sensitive speciation of V(IV) and V(V) at trace levels in complex samples.
Collapse
Affiliation(s)
- Xiaochong Song
- Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China
| | - Mingming Peng
- Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China
| | - Qing Luo
- Department of Materials Science and Engineering, College of Materials, Xiamen University, Xiamen, Fujian 361005, China
| | - Xiaojia Huang
- Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
2
|
Jiao H, Bi R, Li F, Chao J, Zhang G, Zhai L, Hu L, Wang Z, Dai C, Li B. Rapid, easy and catalyst-free preparation of magnetic thiourea-based covalent organic frameworks at room temperature for enrichment and speciation of mercury with HPLC-ICP-MS. J Chromatogr A 2024; 1717:464683. [PMID: 38295741 DOI: 10.1016/j.chroma.2024.464683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/14/2024] [Accepted: 01/25/2024] [Indexed: 02/23/2024]
Abstract
The complex and cumbersome preparation of magnetic covalent organic frameworks (COFs) nanocomposites on a small scale limits their application. Herein, a rapid and easy route was employed for the preparation of magnetic thiourea-based COFs nanocomposites. COFs were coated on Fe3O4 nanoparticles at room temperature without a catalyst within approximately 30 min. This method is suitable for the large-scale preparation of magnetic adsorbent. Using the as-prepared magnetic adsorbent (Fe3O4@COF-TpTU), we developed a simple, efficient, and sensitive magnetic solid-phase extraction-high performance liquid chromatography-inductively coupled plasma-mass spectrometry (MSPE-HPLC-ICP-MS) for the enrichment and determination of mercury species, including Hg2+, methylmercury (MeHg), and ethylmercury (EtHg). The effects of the experimental parameters on the extraction efficiency, including solution pH, adsorption and desorption time, composition and volume of the elution solvent, salinity, coexisting ions, and dissolved organic matter, were comprehensively investigated. Under optimised conditions, the limits of detection in the developed method were 0.56, 0.34, and 0.47 ng L-1 with enrichment factors of 190, 195, and 180-fold for Hg2+, MeHg, and EtHg, respectively. The satisfactory spiked recoveries (97.0-103%) in real water samples and high consistency between the certified and determined values in a certified reference material demonstrate the high accuracy and reproducibility of the developed method. The as-proposed method with simple operation, high sensitivity, and excellent anti-matrix interference performance was successfully applied to the enrichment and determination of trace levels of mercury species in the natural samples with complicated matrices, such as underground water, surface water, seawater and biological samples.
Collapse
Affiliation(s)
- Heping Jiao
- Shandong Analysis and Tester Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
| | - Ruixiang Bi
- School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China
| | - Fangli Li
- Shandong Public Health Clinic Center, Jinan 266075, China
| | - Jingbo Chao
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing 100029, China
| | - Guimin Zhang
- National Engineering and Technology Research Centre of Chirality Pharmaceutical, Lunan Pharmaceutical Group Co., Ltd., Linyi 276005, China
| | - Lihai Zhai
- National Engineering and Technology Research Centre of Chirality Pharmaceutical, Lunan Pharmaceutical Group Co., Ltd., Linyi 276005, China
| | - Ligang Hu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Zhenhua Wang
- Shandong Analysis and Tester Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China.
| | - Caifeng Dai
- Center for Reproductive Medicine, Department of Obstetrics and Gynecology, Qilu Hospital of Shandong University, Jinan, Shandong 250012, China.
| | - Bing Li
- Shandong Analysis and Tester Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China; Shandong Key Laboratory for Adhesive Materials, Advanced Materials Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China.
| |
Collapse
|