1
|
Chen S, Darby I. Inter-implant distance and buccal bone thickness for a novel implant design: a preclinical study. Clin Oral Investig 2023; 27:3261-3274. [PMID: 36944803 PMCID: PMC10264275 DOI: 10.1007/s00784-023-04942-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 03/06/2023] [Indexed: 03/23/2023]
Abstract
OBJECTIVES This study assessed bone height between novel tapered implants at different inter-implant thread peak (TP) distances, and the impact of TP distance from outer buccal bone (BB) on marginal bone levels (MBL). MATERIALS AND METHODS Fully tapered implants with 0.5-mm thread depth and TP diameter 1 mm wider than the shoulder diameter were placed in healed ridges of minipigs. On one side, four implants were placed with inter-implant TP distances of 1, 2, or 3 mm corresponding to inter-implant implant shoulder distances of 2, 3, and 4 mm respectively. Three implants were placed on the other side with TP distances to outer BB of > 1 mm, 0.5-1 mm, or < 0.5 mm. After 12 weeks, (a) first bone-to-implant contact (fBIC), total BIC, bone area-to-total area (BATA), and coronal bone height between implants (Bi ½ max) for inter-implant distance, and (b) fBIC, BIC, and perpendicular crest to implant shoulder (pCIS) for BB were evaluated. RESULTS No significant differences in bone healing and inter-implant bone height were noted for any of the TP distances. BB resorption was significant when TP distance to outer BB was < 0.5 mm. However, fBIC was lowest with TP to outer BB of 1.75 mm. CONCLUSIONS Inter-implant bone height between adjacent implants can be maintained even at an inter-implant TP distance as low as 1 mm. A minimum TP to outer BB distance of 0.75 mm is required for predictable maintenance of MBL. CLINICAL RELEVANCE Inter-implant distance and BB thickness are clinically relevant and require preclinical research to clarify concepts.
Collapse
Affiliation(s)
- Stephen Chen
- Periodontics, Melbourne Dental School, The University of Melbourne, Victoria, Australia.
| | - Ivan Darby
- Periodontics, Melbourne Dental School, The University of Melbourne, Victoria, Australia
| |
Collapse
|
2
|
Cavalcante MS, Ferraro-Bezerra M, de Barros Silva PG, Andrade GS, Alencar PNB, da Silva Ferreira Filho J, Maia LA, da Silva RADA, Moreira DM, Avelar RL. Influence of design implant and apical depth in post-extraction sockets: an in vitro simulated study. BMC Oral Health 2023; 23:322. [PMID: 37231426 DOI: 10.1186/s12903-023-02999-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 04/29/2023] [Indexed: 05/27/2023] Open
Abstract
BACKGROUND Implant design and apical stability are principal parameters involved in achieving successful primary stability. Using polyurethane models to simulate post-extraction sockets, we investigated the effects of using differing blade designs on the primary stability of tapered implants and the impact of apical depth. METHOD Six polyurethane blocks were used to simulate post-extraction pockets. One of the implants presented self-tapping blades (Group A), while the other (Group B) did not. Seventy-two implants were placed at 3 different depths (5 mm, 7 mm, and 9 mm), and a torque wrench was used to measure the stability of the implants. RESULTS When evaluating the implants (placed at 5 mm, 7 mm, and 9 mm apical to the socket), we observed that the torque of the Group B implants was higher than that of Group A implants (P < 0.01). At the 9-mm depth, there was no difference between the groups (Drive GM 34.92 Ncm and Helix GM 32.33 Ncm) (P > 0.001), and considering the same implant groups, those placed at 7-mm and 9-mm depths presented higher torques (p < 0.01) than those placed at 5-mm (p > 0.01). CONCLUSION Considering both groups, we concluded that an insertion depth of greater than 7 mm is needed for initial stability, and in situations involving reduced supportive bone tissue or low bone density, a non-self-tapping thread design improves implant stability.
Collapse
Affiliation(s)
- Marcelo Sales Cavalcante
- School of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil
| | - Marcelo Ferraro-Bezerra
- Department of Clinical Dentistry, Oral and Maxillofacial Surgery Service, Federal University of Ceará, Walter Cantídio University Hospital, Fortaleza, Brazil
| | | | - Gabriel Silva Andrade
- School of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil
| | | | | | - Lucas Alexandre Maia
- School of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil
| | | | - Danna Mota Moreira
- School of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil
| | - Rafael Linard Avelar
- School of Dentistry, Center University Christus, 133, Adolfo Gurgel Street, Fortaleza, CE, Brazil.
| |
Collapse
|
3
|
Clinical, radiographic and restorative parameters for short tuberosity implants placed in smokers: a retrospective study with 5 year follow-up. Odontology 2021; 109:979-986. [PMID: 34240298 DOI: 10.1007/s10266-021-00623-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Accepted: 06/03/2021] [Indexed: 10/20/2022]
Abstract
This study aimed to estimate and compare the clinical, radiographic, and restorative parameters around short tuberosity implants (STIs) placed in cigarette smokers (CS) and never smokers (NS). In this 60-month follow-up retrospective study, a total of 50 (37 males + 13 females) individuals who had received 82 dental implants were included. These participants were categorized into two groups as follows: (i) Group-1: 25 self-reported systemically healthy CS with 43 STIs; and (ii) Group-2: 25 self-reported systemically healthy NS with 39 STIs. In both groups, peri-implant plaque index (PI), probing depth (PD), bleeding on probing (BOP), and crestal bone loss (CBL) and restorative parameters were measured at 12 and 60 months of follow-up. Group comparisons were performed utilizing the Kruskal-Wallis test. The significance level was set at p < 0.05. In CS and NS, the mean age of participants was 58.5 and 60.7 years, respectively. No statistically significant differences were observed in the overall mean levels of PD and CBL around STIs among CS and NS. However, a statistically significant increase was observed in the mean scores of BOP and PI around STIs in the NS and CS at 12 and 60 months follow-up, respectively. In both groups, the loosening of the implant was the most frequently encountered type of STI failure. The outcomes of the present study suggest that STIs placed in maxillary tuberosity can show reliable clinical, radiographic, and restorative stability among cigarettes smokers and non-smokers. However, the role of smoking status and oral hygiene cannot be disregarded in this scenario.
Collapse
|
4
|
Iinuma Y, Hirota M, Hayakawa T, Ohkubo C. Surrounding Tissue Response to Surface-Treated Zirconia Implants. MATERIALS 2019; 13:ma13010030. [PMID: 31861679 PMCID: PMC6981750 DOI: 10.3390/ma13010030] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 12/06/2019] [Accepted: 12/16/2019] [Indexed: 11/16/2022]
Abstract
Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which are partially stabilized zirconia, have been used for fabricating dental implants. This study investigated the soft tissue attachment, the collagen fiber orientation to zirconia at different surface conditions, and the bone response using implantation experiments in animals. The zirconia implant surfaces were treated with ultraviolet irradiation (UV), a combination of large-grit sandblasting and hydrofluoric acid etching (blastedHF), and a combination of blastedHF and UV (blastedHF+UV). The surface treated with blastedHF and blastedHF+UV appeared rough and hydrophilic. The surface treated with blastedHF+UV appeared to be superhydrophilic. Subsequently, tapered cylindrical zirconia implants were placed in the alveolar sockets of the maxillary molars of rats. The bone-to-implant contact ratio of blastedHF and blastedHF+UV implants was significantly higher than that of the non-treated controls and UV-treated implants. The four different surface-treated zirconia implants demonstrated tight soft tissue attachments. Perpendicularly oriented collagen fibers towards zirconia implants were more prominent in blastedHF and blastedHF+UV implants compared to the controls and UV-treated implants. The area of the soft tissue attachment was the greatest with the perpendicularly oriented collagen fibers of blastedHF+UV-treated implants. In conclusion, blastedHF+UV treatment could be beneficial for ensuring greater soft-tissue attachment for zirconia implants.
Collapse
Affiliation(s)
- Yohei Iinuma
- Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan;
- Correspondence: ; Tel.: +81-45580-8421
| | - Masatsugu Hirota
- School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan; (M.H.); (T.H.)
| | - Tohru Hayakawa
- School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan; (M.H.); (T.H.)
| | - Chikahiro Ohkubo
- Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan;
| |
Collapse
|
5
|
Muñoz L, Cardona.-Ramirez S, Silva R. Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits. ARQ BRAS MED VET ZOO 2019. [DOI: 10.1590/1678-4162-11407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
ABSTRACT Hydroxyapatite (HA) is widely used as a biomaterial for bone repair and metallic prostheses coating. The main limitations of the current commercial synthetic hydroxyapatite compounds include high cost and decreased availability, especially for veterinary medicine purposes. Additionally, it is thought that HA biocompatibility and bioactivity could be enhanced by the addition of metal compounds. The objective of this work was to compare the subcutaneous tissue response of commercial and engineered hydroxyapatite obtained from the bovine femur diaphysis mixed with different concentrations of hexa-hydrated Zinc Nitrate in rabbits. Twenty-Five New Zealand female rabbits were used. Five treatments were done according to HA composition (commercial HA, no Zn-HA, 0.1M Zn, 0.2M Zn, and 0.3M Zn). Each treatment was evaluated at five time-points (8, 15, 30, 60 and 90 days post-implantation). Histopathologic analysis was performed to assess inflammation by polymorphonuclear cells infiltration, neovascularization, and fibrosis. Results obtained in this work suggest that general inflammation decreased after 60 days of implantation regardless of Zn concentration. Fibrosis score was increased in the commercial HP compared to control and Zn-hydrated HA. This paper shows that bovine hydroxyapatite is a biocompatible material regardless of nitrate Zinc concentration and has the same properties of commercial hydroxyapatite.
Collapse
|
6
|
Nicolielo LFP, Van Dessel J, Jacobs R, Quirino Silveira Soares M, Collaert B. Relationship between trabecular bone architecture and early dental implant failure in the posterior region of the mandible. Clin Oral Implants Res 2019; 31:153-161. [DOI: 10.1111/clr.13551] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Revised: 09/17/2019] [Accepted: 10/19/2019] [Indexed: 12/17/2022]
Affiliation(s)
- Laura Ferreira Pinheiro Nicolielo
- OMFS‐IMPATH research group Dept. Imaging & Pathology Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery University Hospitals Leuven Leuven Belgium
| | - Jeroen Van Dessel
- OMFS‐IMPATH research group Dept. Imaging & Pathology Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery University Hospitals Leuven Leuven Belgium
| | - Reinhilde Jacobs
- OMFS‐IMPATH research group Dept. Imaging & Pathology Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery University Hospitals Leuven Leuven Belgium
- Dept. of Dental Medicine Karolinska Institutet Huddinge Sweden
| | | | - Bruno Collaert
- Center for Periodontology and Implantology Leuven Heverlee Belgium
| |
Collapse
|
7
|
Podaropoulos L. Increasing the Stability of Dental Implants: the Concept of Osseodensification. BALKAN JOURNAL OF DENTAL MEDICINE 2017. [DOI: 10.1515/bjdm-2017-0023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Summary
One of the most important factors that affect osseointegration is the primary stability of the implant. Dental implants inserted at the posterior region of the maxilla exhibit the lowest success rates as the low density bone in this area often jeopardize rigid fixation of the implant. Many surgical techniques have been developed to increase the primary stability of an implant placed in low density bone, such as bicortical fixation of the implant, undersized preparation of the implant bed and bone condensation by the use of osteotomes. A new promising technique, named osseodensification, has been recently developed that creates an autograft layer of condensed bone at the periphery of the implant bed by the aid of specially designed burs rotating in a clockwise and anti-clockwise direction. The purpose of this review is to emphasize that implant primary stability is strongly influenced by the surgical technique, to quote and briefly analyse the various surgical procedures laying weight to osseodensification procedure.
Collapse
Affiliation(s)
- Leonidas Podaropoulos
- Department of Oral and Maxillofacial Surgery, Dental School, National and Kapodistrian, University of Athens , Greece
| |
Collapse
|
8
|
Correlation of bone vascularity in the posterior mandible and subsequent implant stability: a preliminary study. IMPLANT DENT 2016; 23:200-5. [PMID: 24614879 DOI: 10.1097/id.0000000000000057] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Bone vascularity is an important factor in process of osseointegration. The aim of this study was to find whether or not blood perfusion of the bone around the prepared implant sites influences subsequent implant stability. METHODS Patients with bilaterally edentulous mandible were treated with dental implants. Bone vascularity in implant sites was previously noted using Laser Doppler Flowmetry (LDF). Implant stability quotient (ISQ) was measured during follow-up period of 26th week. Statistical distribution and correlation between LDF and ISQ values were presented. Other variables (type of implant loading; sex and distance from the apical part of implant sites to the roof of the mandibular canal) were collected and correlated with LDF values. RESULTS The mean recorded LDF value was 53.05 perfusion unit. Eighteen implants were immediately loaded, and the other 18 were early loaded. In the group of early loaded implants, a statistically significant correlation between mean value of LDF and changing value of resonance frequency analysis (P < 0.05) was noted at 5th, 6th, 12th, and 26th weeks. Using Pearson coefficient of correlation, there was no statistically significant relationship between other variables and LDF values. CONCLUSION LDF values of implant sites might determine future implant stability.
Collapse
|
9
|
Al-Juboori MJ, AbdulRahaman SB. The Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period. Open Dent J 2015; 9:243-9. [PMID: 26312095 PMCID: PMC4541338 DOI: 10.2174/1874210601509010243] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Revised: 05/26/2015] [Accepted: 05/31/2015] [Indexed: 11/22/2022] Open
Abstract
Purpose :
When soft tissue flaps are reflected for implant placement, the blood supply from the periosteum to the bone is disrupted. The aim of this study was to compare the effects of the flapless (FL) and full-thickness flap (FT) techniques on implant stability. Methods : Nine patients received 22 implants. The implants were placed using the FL technique on the contralateral side of the jaw; the FT technique was used as the control technique. Resonance frequency analysis (RFA) was performed at the time of implant placement and at 6 and 12 weeks after implant placement. RFA values were compared between the FL and FT groups and between time intervals in the same group. Results : The median (interquartile range [IQR]) RFA values at the time of implant placement were 75.00 (15.00) for the FL technique and 75.00 (9.00) for the FT technique. At 6 weeks, the median (IQR) values were 79 (3.30) for the FL technique and 80 (12.70) for the FT technique. At 12 weeks, the median (IQR) values were 82.3 (3.30) for the FL technique and 82.6 (8.00) for the FT technique. There were no significant differences between the 2 techniques at the time of implant placement, after 6 weeks or after 12 weeks, with p values of 0.994, 0.789, and 0.959, respectively. There were significant differences between the RFA values at the time of implant placement and after 6 weeks for the FL technique (p=0.028) but not for the FT technique (p=0.091). There were also significant differences between the RFA values at 6 weeks and the RFA values at 12 weeks for the FL technique (p=0.007) and for the FT technique (p=0.003). Conclusion : Periosteum preservation during the FL procedure will speed up bone remodeling and result in early secondary implant stability as well as early loading.
Collapse
|
10
|
Anil S, Aldosari AA. Impact of Bone Quality and Implant Type on the Primary Stability: An Experimental Study Using Bovine Bone. J ORAL IMPLANTOL 2015; 41:144-8. [DOI: 10.1563/aaid-joi-d-11-00156] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The purpose of this in vitro study was to compare the primary stability and removal torque of bone level and tissue level implants in different bone qualities. Twenty tissue level and bone level implants (3.3 × 10 mm and 4.1 × 10 mm) were used for assessing the stability in type II and type IV bone. Forty bovine rib blocks were used in this study. The primary stability of the implant was measured by the resonance frequency using an Osstel device. The removal torque values (RTV) of the implants was assessed using a digital torque gauge instrument. The implant stability quotient (ISQ) values and the RTV showed a marginally higher stability with bone level implants as compared to tissue level implants. However, these differences were not statistically significant in both type of bone used (P > 0.05). On the other hand, compared to type IV, type II bone showed significant differences in the ISQ (P < 0.01) and RTV (P < 0.001) of bone level and tissue level implants. The study concluded that bone quality is an important factor in establishing primary stability than the implant dimension. Bone level and tissue level implants of same dimensions can be selected based on the esthetic demands since they showed similar mechanical properties.
Collapse
Affiliation(s)
- Sukumaran Anil
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Abdullah Alfarraj Aldosari
- Department of Prosthetic Science, Dental Implant and Osseointegration Research Chair, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
11
|
Lopes L, da Silva V, Santiago J, Panzarini S, Pellizzer E. Placement of dental implants in the maxillary tuberosity: a systematic review. Int J Oral Maxillofac Surg 2015; 44:229-38. [DOI: 10.1016/j.ijom.2014.08.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Revised: 04/17/2014] [Accepted: 08/14/2014] [Indexed: 10/24/2022]
|
12
|
Fu Y, Zhang Q, Sun Y, Liao W, Bai X, Zhang L, Du L, Jin Y, Wang Q, Li Z, Wang Y. Controlled-release of bone morphogenetic protein-2 from a microsphere coating applied to acid-etched Ti6AL4V implants increases biological bone growth in vivo. J Orthop Res 2014; 32:744-51. [PMID: 24536004 DOI: 10.1002/jor.22594] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Accepted: 01/17/2014] [Indexed: 02/04/2023]
Abstract
A central clinical challenge regarding the surgical treatment of bone and joint conditions is the eventual loosening of an orthopedic implant as a result of insufficient bone ingrowth at the bone-implant interface. We investigated the in vivo effectiveness of a coating containing recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded microspheres applied to acid-etched Ti6Al4V cylinders for implantation. Three groups of rabbits (24 per group) were used for implantation: (1) acid-etched Ti6Al4V implants coated with a mixture of rhBMP-2-loaded microspheres (125 ng rhBMP-2/mg microspheres) and α-butyl cyanoacrylate; (2) acid-etched, uncoated implants; and (3) bare, smooth uncoated implants. After implantation, 12 rabbits from each group were used for bone ingrowth determination at 4, 5, 6, 7, 8, and 12 weeks (2 rabbits per time point), while the remainder were used for histological analysis and push-out testing at 12 weeks. Scanning electron microscopy showed significant improvement in bone growth of the rhBMP-2 microspheres/α-butyl cyanoacrylate group compared with the other groups (p<0.01). Histological analysis and push-out testing also demonstrated enhanced bone growth of the rhBMP-2 group over that in the other two groups (p<0.01). The rhBMP-2 group showed the most significant bone growth, suggesting that coating acid-etched implants with a mixture of rhBMP-2-loaded microspheres and α-butyl cyanoacrylate may be an effective method to improve the osseointegration of orthopedic implants.
Collapse
Affiliation(s)
- Yangmu Fu
- Department of Orthopedics, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Zhang X, Duyck J, Vandamme K, Naert I, Carmeliet G. Ultrastructural characterization of the implant interface response to loading. J Dent Res 2014; 93:313-8. [PMID: 24389808 DOI: 10.1177/0022034513518345] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Dynamic loading can affect the bone surrounding implants. For ultrastructural exploration of the peri-implant tissue response to dynamic loading, titanium implants were installed in rat tibiae, in which one implant was loaded while the contralateral served as the unloaded control. The loaded implants received stimulation either within 24 hrs after implantation (immediate loading) or after a 28-day healing period (delayed loading) for 4, 7, 14, 21, or 28 days. The samples were processed for histology and gene expression quantification. Compared with the unloaded control, bone-to-implant contact increased significantly by immediate loading for 28 days (p < .05), but not in case of delayed loading. No effect of loading was observed on the bone formation in the implant thread areas, on the blood vessel area, and on endosteal callus formation. Loading during healing (immediate) for 7 days induced, relative to the unloaded control, a 2.3-fold increase of Runx2 in peri-implant cortical bone (p < .01) without a change in the RANKL/Opg ratio. Loading after healing (delayed) for 7 days up-regulated Runx2 (4.3-fold, p < .01) as well as Opg (22.3-fold, p < .05) compared with the unloaded control, resulting in a significantly decreased RANKL/Opg ratio. These results indicate a stimulating effect of dynamic loading on implant osseointegration when applied during the healing phase. In addition, gene expression analyses revealed molecular adaptations favoring bone formation and, at the same time, affecting bone remodeling.
Collapse
Affiliation(s)
- X Zhang
- Department of Oral Health Sciences, BIOMAT Research Cluster & Prosthetic Dentistry, KU Leuven & University Hospitals Leuven, Leuven, Belgium
| | | | | | | | | |
Collapse
|
14
|
Qian J, Wennerberg A, Albrektsson T. Reasons for Marginal Bone Loss around Oral Implants. Clin Implant Dent Relat Res 2012. [DOI: 10.1111/cid.12014] [Citation(s) in RCA: 154] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
15
|
Lethaus B, Poort L, Yamauchi K, Kloss-Brandstätter A, Boeckmann R, Kessler P. Qualitative bone CT as a tool to assess vascularization in irradiated bone: an animal study. Clin Oral Implants Res 2012; 24:746-9. [PMID: 22524288 DOI: 10.1111/j.1600-0501.2012.02480.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/02/2012] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The purpose of this paper was to find a correlation between laser doppler flowmetry (LDF) and the bone mineral density quotient (BMDQ) to evaluate irradiated bone quality preoperatively. MATERIALS AND METHODS Premolars and molars were extracted from six minipigs. After a three-month healing period, three animals received irradiation at a total dose of 24 Gy. Three months after irradiation, quantitative computed tomography was performed using a calibration bone phantom to determine the 120-position BMDQ in the alveolar bone. A drill template was created to define the exact location for measurement. LDF was then recorded after osteotomy of the residual alveolar ridge. The correlation between the BMDQ and LDF was investigated. RESULTS There was a linear negative correlation between LDF and BMDQ in non-irradiated bone (r = -0.435, P = 0.001) and less pronounced also in irradiated bone (r = -0.309, P = 0.017). In both non-irradiated and irradiated bone, we found distinct differences between the maxilla and mandible with respect to BMDQ. However, a clear difference in mandibular and maxillary vascularity was only seen in non-irradiated bone. CONCLUSION In non-irradiated bone, LDF and BMDQ were inversely correlated. In irradiated bone, the BMDQ alone is not an adequate preoperative tool for evaluating bone quality because it was not correlated with bone perfusion.
Collapse
Affiliation(s)
- Bernd Lethaus
- Department of Cranio-Maxillofacial Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
16
|
Alghamdi H, Anand PS, Anil S. Undersized Implant Site Preparation to Enhance Primary Implant Stability in Poor Bone Density: A Prospective Clinical Study. J Oral Maxillofac Surg 2011; 69:e506-12. [DOI: 10.1016/j.joms.2011.08.007] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 08/03/2011] [Accepted: 08/05/2011] [Indexed: 10/15/2022]
|
17
|
Verdonck HWD, Meijer GJ, Nieman FH, Stoll C, Riediger D, de Baat C. Quantitative computed tomography bone mineral density measurements in irradiated and non-irradiated minipig alveolar bone: an experimental study. Clin Oral Implants Res 2008; 19:465-8. [PMID: 18371103 DOI: 10.1111/j.1600-0501.2007.01496.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The objective of this study was to analyse the effect of irradiation on bone mineral density (BMD). MATERIALS AND METHODS All maxillary and mandibular pre-molars and molars of six minipigs were extracted. After a 3-month healing period, the maxilla and mandibles of three minipigs received three irradiation exposures at a total dose of 24 Gy. At 3 months after irradiation, quantitative computed tomography (QCT) was performed. As a reference, a calibration bone phantom with pre-determined BMD was attached to the head of the minipigs. The QCT data were imported into a software program to calculate the BMD of the alveolar bone and the calibration bone phantom. In order to compare BMD values of individual minipigs, the so-called bone mineral density quotient (BMDQ) was created, dividing the BMD value of the alveolar bone by the BMD value of the calibration bone phantom. RESULTS Mean BMDQ values appeared to be higher in irradiated than in non-irradiated minipigs. However, the difference was not significant. In both irradiated and non-irradiated minipigs, the average mandibular BMDQ values were statistically significantly higher than the average maxillary BMDQ values (P=0.003). The P-values of the Student t-test, determining the irradiation effect, were 0.11 for maxillary, 0.14 for mandibular, and 0.07 for overall peri-implant BMDQ. P-values of the non-parametric Mann-Whitney test were all 0.05. CONCLUSION It could be concluded that, 3 months after irradiation, the BMD of irradiated alveolar minipig bone was increased, when compared with non-irradiated alveolar minipig bone. However, the increase was not statistically significant.
Collapse
Affiliation(s)
- Henk W D Verdonck
- Department of Oral and Maxillofacial Surgery, University Hospital Maastricht, Maastricht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
18
|
Rabel A, Köhler SG, Schmidt-Westhausen AM. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 2007; 11:257-65. [PMID: 17401588 DOI: 10.1007/s00784-007-0115-2] [Citation(s) in RCA: 90] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2006] [Accepted: 03/12/2007] [Indexed: 10/23/2022]
Abstract
Primary stability has a major impact on the long-term success of dental implants. The aim of this study was to investigate the correlation of resonance frequency analysis (RFA) and insertion torque of self-tapping and non-self-tapping implants and their respective differences in primary stability. A group of 263 patients were treated with a total of 602 conically formed dental implants: 408 non-self-tapping Ankylos and 194 self-tapping Camlog. The maximum insertion torque during implant placement was recorded. Resonance frequency, measured as the implant stability quotient (ISQ), was assessed once immediately after insertion and twice 3 months later. Torque values of the non-self-tapping implants were significantly higher than those in the self-tapping group (p = 0.023). RFA did not show differences between the 2 groups (p = 0.956), but a correlation between ISQ values after implantation and 3 months after implant placement was measured (r = 0.712). Within the implant systems, no correlation between insertion torque and resonance frequency values could be determined (r = 0.305). Our study indicates that the ISQ values obtained from different implant systems are not comparable. The RFA does not appear suitable for the evaluation of implant stability when used as a single method. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical primary stability.
Collapse
Affiliation(s)
- Annette Rabel
- Department of Oral Medicine, Dental Radiology and Surgery, Charité Center 3 for Dental Medicine, Campus Benjamin Franklin, Charité-Medical University Berlin, Assmannshauser Strasse 4-6, 14197, Berlin, Germany.
| | | | | |
Collapse
|
19
|
Schwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Histological and immunohistochemical analysis of initial and early subepithelial connective tissue attachment at chemically modified and conventional SLA®titanium implants. A pilot study in dogs. Clin Oral Investig 2007; 11:245-55. [PMID: 17361452 DOI: 10.1007/s00784-007-0110-7] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2006] [Accepted: 02/13/2007] [Indexed: 11/24/2022]
Abstract
The aim of the present pilot study was to histologically/immunohistochemically investigate initial and early subepithelial connective tissue attachment at transmucosal parts of modified (mod) and conventional sandblasted, large grit and acid-etched (SLA) titanium implants. Implantation of modSLA and SLA implants was performed bilaterally in both the mandible and maxilla of four beagle dogs. The implants were submerged to prevent bacterial contamination. The animals were killed after 1, 4, 7 and 14 days. Peri-implant tissue reactions were assessed histologically (Masson Goldner Trichrome stain-MG) and immunohistochemically (IH) using monoclonal antibodies to fibronectin (FN) and proliferating cell nuclear antigen (PCNA). The surgical procedure of implant submerging resulted in the formation of an artificial gap in the transmucosal area of both types of implants. After 14 days of healing, MG stain revealed the formation of well-organized collagen fibres and numerous blood vessels in a newly formed loose connective tissue zone adjacent to modSLA. While some fibres were oriented in a parallel direction, others have started to extend and attach partially perpendicular to the implant surface. In contrast, SLA implants appeared to be clearly separated by a dense connective tissue zone with parallel-running collagen fibres and rare blood vessel formation. First signs of a positive FN and PCNA staining adjacent to both implant surfaces were observed at day 4. Within the limits of a pilot study, it might be concluded that modSLA titanium surfaces might possess the potential to promote subepithelial connective tissue attachment at the transmucosal part of the implant.
Collapse
Affiliation(s)
- Frank Schwarz
- Department of Oral Surgery, Westdeutsche Kieferklinik, Heinrich Heine University, 40225, Düsseldorf, Germany.
| | | | | | | | | | | |
Collapse
|