Refaie A, Bourauel C, Fouda AM, Keilig L, Singer L. The effect of cyclic loading on the fracture resistance of 3D-printed and CAD/CAM milled zirconia crowns-an in vitro study. Clin Oral Investig 2023; 27:6125-6133. [PMID: 37615777 PMCID: PMC10560138 DOI: 10.1007/s00784-023-05229-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 08/17/2023] [Indexed: 08/25/2023]
Abstract
OBJECTIVES The aim of this study was to evaluate the effect of cyclic mechanical loading on the fracture resistance of 3D-printed zirconia crowns in comparison to milled zirconia crowns. MATERIALS AND METHODS Monolithic zirconia crowns (n = 30) were manufactured using subtractive milling (group M) and 3D additive printing (group P). Nine samples of each group were fractured under one-time loading while the other 6 samples were subjected to cyclic loading for 1.2 million cycles before being subjected to one-time loading until fracture. Scanning electron microscope (SEM) fractographic analysis was carried out on fractured fragments of representative samples. RESULTS The mean for fracture resistance of group M was 1890 N without cyclic loading and 1642 N after being subjected to cyclic loading, and they were significantly higher than that of group P (1658 N and 1224 N respectively). CONCLUSIONS The fabrication technique and cyclic loading affect the fracture resistance of zirconia crowns. Although the fracture resistance values for the 3D-printed crowns were lower than those of the milled, still they are higher than the masticatory forces and thus could be considered being clinically acceptable. CLINICAL RELEVANCE Concerning fracture resistance, 3D-printed crowns can withstand the masticatory forces for the long term without any cracks or failure.
Collapse
Affiliation(s)
- Ashraf Refaie
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany.
- Department of Fixed Prosthodontics, Faculty of Dentistry, Fayoum University, Faiyum, Egypt.
| | - Christoph Bourauel
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany
| | - Ahmed Mahmoud Fouda
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany
- Suez Canal University, Ismailia, Egypt
| | - Ludger Keilig
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Dental School, Medical Faculty, University Hospital of Bonn, 53111, Bonn, North Rhine-Westphalia, Germany
| | - Lamia Singer
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany
- Department of Orthodontic, Dental School, Medical Faculty, University Hospital of Bonn, 53111, Bonn, North Rhine-Westphalia, Germany
| |
Collapse
|
2
|
Maroulakos G, Thompson GA, Kontogiorgos ED. Effect of cement type on the clinical performance and complications of zirconia and lithium disilicate tooth-supported crowns: A systematic review. Report of the Committee on Research in Fixed Prosthodontics of the American Academy of Fixed Prosthodontics. J Prosthet Dent 2019; 121:754-765. [DOI: 10.1016/j.prosdent.2018.10.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 10/17/2018] [Accepted: 10/22/2018] [Indexed: 12/28/2022]
|
3
|
von Stein-Lausnitz M, Bruhnke M, Rosentritt M, Sterzenbach G, Bitter K, Frankenberger R, Naumann M. Direct restoration of endodontically treated maxillary central incisors: post or no post at all? Clin Oral Investig 2018; 23:381-389. [PMID: 29713887 DOI: 10.1007/s00784-018-2446-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Accepted: 04/12/2018] [Indexed: 12/23/2022]
Abstract
OBJECTIVES The aim of this ex-vivo study was to evaluate the impact of cavity size and glass-fiber post (GFP) placement on the load capability of endodontically treated maxillary incisors directly restored with resin composite. MATERIALS AND METHODS Ninety-six extracted human maxillary central incisors were endodontically treated and distributed to four groups (n = 24): access cavity (A), access cavity and uni-proximal class III cavity (U), access cavity and bi-proximal class III cavity (B), and decoronated tooth (D). Specimens were restored with resin composite, and 12 specimen of each group received an adhesively placed glass-fiber post (P). Prior to linear loading, specimens were exposed to thermo-mechanical loading (TCML). Statistical analysis was performed using log-rank test after TCML, Kruskall-Wallis and Mann-Whitney U test to compare load capabilities (Fmax). RESULTS Significantly more failures occurred in group D for specimens without GFP during TCML (p = 0.001). Fmax (mean (SD) in N was (A) 513 (124), (AP) 554 (201), (U) 438 (171), (UP) 537 (232) (B) 483 (219), (BP) 536 (281), D 143 (181), and DP 500 (331), and differed significantly among groups (p = 0.003). Pair-wise comparison revealed lower Fmax values for group D compared to all other groups (p < 0.034) except group DP. CONCLUSIONS Endodontically treated maxillary central incisors with cavity sizes up to bi-proximal class III may be successfully directly restored with resin composite. Post placement shows no additional effect except for decoronated endodontically treated incisors. CLINICAL RELEVANCE Endodontically treated incisors with access cavities to class III cavities can be successfully restored with resin composite. Post placement for decoronated ETT is recommended.
Collapse
Affiliation(s)
- Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197, Berlin, Germany.
| | - M Bruhnke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197, Berlin, Germany
| | - M Rosentritt
- Department of Prosthetic Dentistry, Regensburg University Medical Center, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - G Sterzenbach
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197, Berlin, Germany
| | - K Bitter
- Department of Operative and Preventive Dentistry, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197, Berlin, Germany
| | - R Frankenberger
- Department of Operative Dentistry and Endodontics, University of Marburg, Georg-Voigt-Str. 3, 35039, Marburg, Germany
| | - M Naumann
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197, Berlin, Germany
| |
Collapse
|
4
|
Nawafleh N, Hatamleh M, Elshiyab S, Mack F. Lithium Disilicate Restorations Fatigue Testing Parameters: A Systematic Review. J Prosthodont 2015; 25:116-26. [PMID: 26505638 DOI: 10.1111/jopr.12376] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/07/2015] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To review laboratory studies that investigated fatigue resistance of lithium disilicate (LD) crowns and fixed dental prostheses (FDPs) to elucidate study designs and testing parameters. METHODS An electronic search was performed in PubMed, Scopus, and Ovid to identify in vitro studies that investigated fatigue resistance of LD crowns and FDPs. The search included all studies published in English in peer-reviewed journals in the period from 1998 to June 2014. The search followed a specific strategy that included combination of the following keywords: lithium disilicate, e.max, empress, all-ceramic, all ceramic, glass ceramic, fatigue, cyclic loading, dynamic loading, chewing simulator, fracture resistance, thermocycling, laboratory simulation, aging, crown, FDPs, FPDs, fixed partial denture, fixed dental prosthesis, and bridge. Studies were selected if mechanical and thermal loading parameters were clearly identified. Search results with abstracts were transferred into Endnote reference system, and duplicates were deleted. The remaining studies were then reviewed at three levels (title, abstract, full text) to further refine the articles. RESULTS The initial search retrieved 1044 eligible studies. After deduplication, 864 records were examined by titles and then abstracts; 826 were excluded, and 38 were assessed by full-text reading. In total, 19 articles met inclusion criteria and were included in this study. CONCLUSION The studies reviewed showed a level of heterogeneity, as testing parameters were considered through different setups. The current study demonstrated that various setting of the testing parameters and having a lack of testing standardization has likely led to inconsistency in the reported results. The obvious heterogeneity in the setting of testing variables-especially the magnitude of load and number of cycles applied-made it impractical to run direct comparisons between the reviewed studies. Therefore, specific international standardization of fatigue testing of dental restorations is urgently needed to ensure the delivery of consistent, indicative, and comparable data.
Collapse
Affiliation(s)
- Noor Nawafleh
- School of Dentistry and Oral Health, Griffith University, Queensland, Australia
| | - Muhanad Hatamleh
- Cranio-Maxillofacial Prosthetics Unit, King's College Hospital NHS Foundation Trust, London, UK
| | - Shareen Elshiyab
- School of Dentistry and Oral Health, Griffith University, Queensland, Australia
| | - Florian Mack
- School of Dentistry and Oral Health, Griffith University, Queensland, Australia
| |
Collapse
|
5
|
Tunjan R, Rosentritt M, Sterzenbach G, Happe A, Frankenberger R, Seemann R, Naumann M. Are endodontically treated incisors reliable abutments for zirconia-based fixed partial dentures in the esthetic zone? J Endod 2012; 38:519-22. [PMID: 22414841 DOI: 10.1016/j.joen.2011.12.027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2011] [Revised: 12/16/2011] [Accepted: 12/19/2011] [Indexed: 02/06/2023]
Abstract
INTRODUCTION This ex vivo pilot study tested the influence of defect extension and quartz-fiber post placement (QFP) on the ex vivo survival rate and fracture resistance of root-treated upper central incisors served as abutments for zirconia 2-unit cantilever fixed partial dentures (2U-FPDs) exposed to 10 years of simulated clinical function. METHODS Human maxillary central incisors were endodontically treated and divided into the following 5 groups (n = 8): (1) access cavity filled with core build-up composite, (2) biproximal class III cavities filled as in group 1, (3) specimens restored as in group 2 with QFP placed, (4) specimens decoronated and core buildup as in group 1, and (5) specimens restored as in group 4 but with QFP as in group 3. On all specimens, 2U-FPDs were placed with dual-curing resin cement. In order to simulate 10 years of clinical function, specimens were exposed to thermal cycling and mechanical loading with subsequent loading to failure. Kaplan-Meier curves were constructed, and log-rank tests were performed. Fracture force and patterns were compared by means of Kruskal-Wallis, Mann-Whitney U (post hoc), and Fisher exact tests, respectively (P = .05). RESULTS For specimens only with an access cavity, it was observed that 25% had catastrophic tooth fractures and the lowest load-to-fracture values. In all other groups, chipping combined with or without debonding occurred. Groups did not differ significantly regarding the survival rate (P = .603) and fracture patterns (P = .633), but they did for fracture load including technical failures (P = .017). CONCLUSIONS After 10 years of simulated clinical function, both defect extension and placement of QFP had no significant influence on survival of root-treated upper central incisors as abutments restored with zirconia-based 2U-FPDs.
Collapse
Affiliation(s)
- René Tunjan
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | | | | | | |
Collapse
|
6
|
Yucel MT, Yondem I, Aykent F, Eraslan O. Influence of the supporting die structures on the fracture strength of all-ceramic materials. Clin Oral Investig 2011; 16:1105-10. [PMID: 21845404 DOI: 10.1007/s00784-011-0606-z] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Accepted: 08/05/2011] [Indexed: 11/24/2022]
Abstract
This study investigated the influence of the elastic modulus of supporting dies on the fracture strengths of all-ceramic materials used in dental crowns. Four different types of supporting die materials (dentin, epoxy resin, brass, and stainless steel) (24 per group) were prepared using a milling machine to simulate a mandibular molar all-ceramic core preparation. A total number of 96 zirconia cores were fabricated using a CAD/CAM system. The specimens were divided into two groups. In the first group, cores were cemented to substructures using a dual-cure resin cement. In the second group, cores were not cemented to the supporting dies. The specimens were loaded using a universal testing machine at a crosshead speed of 0.5 mm/min until fracture occurred. Data were statistically analyzed using two-way analysis of variance and Tukey HSD tests (α = 0.05). The geometric models of cores and supporting die materials were developed using finite element method to obtain the stress distribution of the forces. Cemented groups showed statistically higher fracture strength values than non-cemented groups. While ceramic cores on stainless steel dies showed the highest fracture strength values, ceramic cores on dentin dies showed the lowest fracture strength values among the groups. The elastic modulus of the supporting die structure is a significant factor in determining the fracture resistance of all-ceramic crowns. Using supporting die structures that have a low elastic modulus may be suitable for fracture strength tests, in order to accurately reflect clinical conditions.
Collapse
Affiliation(s)
- Munir Tolga Yucel
- Department of Prosthodontics, Faculty of Dentistry, University of Selcuk, 42079 Kampus Konya, Turkey.
| | | | | | | |
Collapse
|
7
|
Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements. Clin Oral Investig 2011; 16:505-12. [DOI: 10.1007/s00784-011-0527-x] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Accepted: 02/15/2011] [Indexed: 10/18/2022]
|
8
|
FERRACANE JL, STANSBURY JW, BURKE FJT. Self-adhesive resin cements - chemistry, properties and clinical considerations. J Oral Rehabil 2010; 38:295-314. [DOI: 10.1111/j.1365-2842.2010.02148.x] [Citation(s) in RCA: 268] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
Lencioni KA, Menani LR, Macedo AP, Ribeiro RF, de Almeida RP. Tensile bond strength of cast commercially pure titanium dowel and cores cemented with three luting agents. J Prosthodont Res 2010; 54:164-7. [PMID: 20363204 DOI: 10.1016/j.jpor.2010.03.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2009] [Revised: 02/23/2010] [Accepted: 03/10/2010] [Indexed: 10/19/2022]
Abstract
PURPOSE The purpose of this study was to compare the tensile strength of commercially pure titanium dowels and cores cemented with zinc phosphate or resin cements. METHODS Twenty-one extracted human canines were endodontically treated. The root preparations were accomplished using Largo reamers (10mm in depth and 1.7 mm in diameter). Acrylic resin patterns for the dowel and cores were made, and specimens were cast in commercially pure titanium (n=7) and divided in three groups: TZ-CP Ti dowels luted with zinc phosphate luting agent, TP-CP Ti dowels luted with Panavia F and TR-CP Ti dowels luted with RelyX U100. Tensile strengths were measured in a universal testing machine at a crosshead speed of 0.5mm/min. The results (N) were statistically analyzed by ANOVA and Tukey tests (α=0.01). RESULTS The ANOVA indicated that there were significant differences among the groups tested. A Tukey multiple comparison procedure was performed and revealed statistically significant higher retention values for the dowel luted with RelyX U100 when compared with zinc phosphate or Panavia F. CONCLUSION Cast commercially pure titanium dowels and cores fixed with RelyX U100 cement presented superior bond strength retention when compared to zinc phosphate and Panavia F.
Collapse
Affiliation(s)
- Karina Albino Lencioni
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Brazil
| | | | | | | | | |
Collapse
|
10
|
Krifka S, Stangl M, Wiesbauer S, Hiller KA, Schmalz G, Federlin M. Influence of different cusp coverage methods for the extension of ceramic inlays on marginal integrity and enamel crack formation in vitro. Clin Oral Investig 2009; 13:333-41. [DOI: 10.1007/s00784-008-0239-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2008] [Accepted: 12/03/2008] [Indexed: 11/28/2022]
|
11
|
The impact of cement mixing and storage errors on the risk of failure of glass–ceramic crowns. Clin Oral Investig 2008; 13:217-22. [DOI: 10.1007/s00784-008-0215-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2007] [Accepted: 07/15/2008] [Indexed: 11/24/2022]
|