• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4622678)   Today's Articles (29)   Subscriber (49406)
For: Hellén-Halme K. Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study. Clin Oral Investig 2010;15:209-13. [PMID: 20143243 DOI: 10.1007/s00784-010-0383-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2009] [Accepted: 01/11/2010] [Indexed: 11/26/2022]
Number Cited by Other Article(s)
1
Ardila CM, Vivares-Builes AM, Pineda-Vélez E. Image Quality, Radiation Dose, and Patient Comfort Associated with Wireless Sensors in Digital Radiography: A Systematic Review. Dent J (Basel) 2024;12:267. [PMID: 39195111 DOI: 10.3390/dj12080267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Revised: 08/09/2024] [Accepted: 08/14/2024] [Indexed: 08/29/2024]  Open
2
Hellén-Halme K, Johansson C, Nilsson M. Comparison of the performance of intraoral X-ray sensors using objective image quality assessment. Oral Surg Oral Med Oral Pathol Oral Radiol 2016;121:e129-37. [PMID: 27068317 DOI: 10.1016/j.oooo.2016.01.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2015] [Revised: 12/15/2015] [Accepted: 01/23/2016] [Indexed: 11/26/2022]
3
Silverstrim KJ, Schneider E, van der Hoeven C. Image optimization in digital dental radiography. HEALTH PHYSICS 2015;108:580-591. [PMID: 25905519 DOI: 10.1097/hp.0000000000000273] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
4
Hellén-Halme K, Nilsson M. The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging. EJOURNAL OF ORAL MAXILLOFACIAL RESEARCH 2013;4:e2. [PMID: 24422035 PMCID: PMC3887573 DOI: 10.5037/jomr.2013.4302] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2012] [Accepted: 07/07/2013] [Indexed: 01/25/2023]
5
Schropp L, Alyass NS, Wenzel A, Stavropoulos A. Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies. Dentomaxillofac Radiol 2012;41:686-90. [PMID: 22933536 DOI: 10.1259/dmfr/33467269] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]  Open
6
Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth. Clin Oral Investig 2010;15:901-7. [PMID: 20838834 DOI: 10.1007/s00784-010-0461-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2009] [Accepted: 08/23/2010] [Indexed: 10/19/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA