1
|
Schnutenhaus S, Brunken L, Edelmann C, Dreyhaupt J, Rudolph H, Luthardt RG. Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial. BMC Oral Health 2020; 20:178. [PMID: 32600405 PMCID: PMC7322921 DOI: 10.1186/s12903-020-01155-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 06/01/2020] [Indexed: 11/17/2022] Open
Abstract
Background The aim of this prospective clinical study was to investigate differences between virtually planned and clinically achieved implant positions in completely template-guided implant placements as a function of the tooth area, the use of alveolar ridge preservation, the implant length and diameter, and the primary implant stability. Methods The accuracy of 48 implants was analyzed. The implants were placed in a completely template-guided manner. The data of the planned implant positions were superimposed on the actual clinical implant positions, followed by measurements of the 3D deviations in terms of the coronal (dc) and apical distance (da), height (h), angulation (ang), and statistical analysis. Results The mean dc was 0.7 mm (SD: 0.3), the mean da was 1.4 mm (SD: 0.6), the mean h was 0.3 mm (SD: 0.3), and the mean ang was 4.1° (SD: 2.1). The tooth area and the use of alveolar ridge preservation had no significant effect on the results in terms of the implant positions. The implant length had a significant influence on da (p = 0.02). The implant diameter had a significant influence on ang (p = 0.04), and the primary stability had a significant influence on h (p = 0.02). Conclusion Template-guided implant placement offers a high degree of accuracy independent of the tooth area, the use of measures for alveolar ridge preservation or the implant configuration. A clinical benefit is therefore present, especially from a prosthetic point of view. Trial registration German Clinical Trial Register and the International Clinical Trials Registry Platform of the WHO: DRKS00005978; date of registration: 11/09/2015.
Collapse
Affiliation(s)
- Sigmar Schnutenhaus
- Zentrum für Zahnmedizin Dr. Schnutenhaus MVZ GmbH [Center for Dentistry Dr. Schnutenhaus Community Health Center (CHC) GmbH], Breiter Wasmen 10, 78247, Hilzingen, Germany. .,Department for Dentistry, Clinic for Prosthodontics, Universität Ulm, Department für Zahnheilkunde, Klinik für Zahnärztliche Prothetik [Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany.
| | - Liesa Brunken
- Department for Dentistry, Clinic for Prosthodontics, Universität Ulm, Department für Zahnheilkunde, Klinik für Zahnärztliche Prothetik [Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany
| | - Cornelia Edelmann
- Zentrum für Zahnmedizin Dr. Schnutenhaus MVZ GmbH [Center for Dentistry Dr. Schnutenhaus Community Health Center (CHC) GmbH], Breiter Wasmen 10, 78247, Hilzingen, Germany
| | - Jens Dreyhaupt
- Universität Ulm, Institut für Epidemiologie und Medizinische Biometrie [Ulm University, Institute of Epidemiology and Medical Biometry], Schwabstr. 13, 89075, Ulm, Germany
| | - Heike Rudolph
- Department for Dentistry, Clinic for Prosthodontics, Universität Ulm, Department für Zahnheilkunde, Klinik für Zahnärztliche Prothetik [Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany
| | - Ralph G Luthardt
- Department for Dentistry, Clinic for Prosthodontics, Universität Ulm, Department für Zahnheilkunde, Klinik für Zahnärztliche Prothetik [Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany
| |
Collapse
|
2
|
Joós-Kovács G, Vecsei B, Körmendi S, Gyarmathy VA, Borbély J, Hermann P. Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study. BMC Oral Health 2019; 19:280. [PMID: 31830970 PMCID: PMC6909471 DOI: 10.1186/s12903-019-0976-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 11/28/2019] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Desktop scanners are devices for digitization of conventional impressions or gypsum casts by indirect Computer-Aided Design/Computer-Assisted Manufacturing (CAD/CAM) in dentistry. The purpose of this in vitro study was: 1, to investigate whether virtual models produced by the extraoral scanner have the same trueness as sectioned casts; and 2, to assess if digitization with an extraoral scanner influences the surface information. METHODS A polimethyl-methacrilic acid (PMMA) cast and a reference scanner (TwoCam 3D, SCAN technology A/S, Ringsted, Denmark; field of view 200 mm, resolution 0.1 mm ± 0.025 mm) were used to create the reference data in standard tessellation format (STL). According to the extraoral CAD/CAM digitization steps, impressions, mastercasts, and sectioned casts were made, and STL files were generated with the reference scanner. The pivotal point of the study was to digitalize these sectioned casts with the extraoral scanner (Straumann CARES Scan CS2 Visual 8.0 software, InstitutStraumann AG, Basel, Switzerland) and STL files were exported. Virtual caliper measurements were performed. Absolute deviations were compared using multilevel mixed-effects linear regression. Relative distortions were calculated with mean absolute errors and reference values. RESULTS Differences were observed in measurements of tooth sizes. All four prepared teeth were affected. No relationship was observed in relative deviations. Absolute differences between all the indirect digitization steps considering arch distances were: impressions, - 0.004 mm; mastercasts, 0.136 mm; sectioned casts, - 0.028 mm; and extraoral scanner, - 0.089 mm. Prepared dies on the virtual casts (extraoral scanner) were closer to each other than those on the sectioned gypsum casts. Relative deviation calculations revealed no relationship with the position of the dies in the arch. CONCLUSION The trueness of the virtual models generated by the extraoral scanner system used in this study was different from the dimensions of the sectioned casts. The digitization of gypsum casts changes both the dimensions of dies and the distances between the dies. The virtual casts had smaller distances than any distances measured at previous steps. Either bigger dies or longer distances did not result in greater distortions. We cannot, however, generalize our results to all scanners available on the market, because they might give different results.
Collapse
Affiliation(s)
- G. Joós-Kovács
- Department of Prosthodontics, Semmelweis University, Szentkirályi u. 47, Budapest, 1088 Hungary
| | - B. Vecsei
- Department of Prosthodontics, Semmelweis University, Szentkirályi u. 47, Budapest, 1088 Hungary
| | - Sz. Körmendi
- Department of Prosthodontics, Semmelweis University, Szentkirályi u. 47, Budapest, 1088 Hungary
| | - V. A. Gyarmathy
- EpiConsult LLC, 8 The Green, STE A, Dover, DE 19901 USA
- Johns Hopkins Bloomberg School of Public Health, Baltimore, MD USA
| | - J. Borbély
- Department of Prosthodontics, Semmelweis University, Szentkirályi u. 47, Budapest, 1088 Hungary
| | - P. Hermann
- Department of Prosthodontics, Semmelweis University, Szentkirályi u. 47, Budapest, 1088 Hungary
| |
Collapse
|
3
|
Oh KC, Lee B, Park YB, Moon HS. Accuracy of Three Digitization Methods for the Dental Arch with Various Tooth Preparation Designs: An In Vitro Study. J Prosthodont 2018; 28:195-201. [DOI: 10.1111/jopr.12998] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/26/2018] [Indexed: 11/30/2022] Open
Affiliation(s)
- Kyung Chul Oh
- Department of Prosthodontics; College of Dentistry; Yonsei University; Seoul Republic of Korea
| | - Bora Lee
- Dental Education Research Center; College of Dentistry; Yonsei University; Seoul Republic of Korea
| | - Young-Bum Park
- Department of Prosthodontics; College of Dentistry; Yonsei University; Seoul Republic of Korea
| | - Hong Seok Moon
- Department of Prosthodontics; College of Dentistry; Yonsei University; Seoul Republic of Korea
| |
Collapse
|
4
|
Conformity, reliability and validity of digital dental models created by clinical intraoral scanning and extraoral plaster model digitization workflows. Comput Biol Med 2018; 100:114-122. [PMID: 29990644 DOI: 10.1016/j.compbiomed.2018.06.035] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 06/24/2018] [Accepted: 06/28/2018] [Indexed: 11/23/2022]
Abstract
BACKGROUND In dentistry, digitization of dental arches with intraoral scanners could one day replace impressions and plaster model digitization processes, if accuracy is clinically sufficient. This study aimed to assess the reliability, validity and conformity of an intraoral scanning procedure (Lythos©, Ormco) and of two extraoral digitization workflows via alginate impression and plaster model scanning with the D810© (3shape) or the Atos II Triple Scan© (GOM) under clinical conditions. METHODS In 20 subjects three consecutive intraoral scans, three alginate and one reference polyether impression were taken of both the upper and lower dental arch, respectively. The digital models created from the corresponding plaster models and the intraoral scans were superimposed with the polyether reference standard by both a global and a local best-fit algorithm. Reliability, validity and conformity of the three digital workflows were assessed via intraclass (ICC) and Lin's concordance correlation coefficients (CCC) as well as analyses according to Bland-Altman. RESULTS The digital models created from the intraoral scanning procedure were less in agreement with the polyether reference (validity) than those from the extraoral procedures with reduced conformity and reliability. Local numerical deviations from the reference standard were approximately twice as high compared to the extraoral procedures, which showed high conformity and were equivalent and clinically acceptable in terms of reliability and validity. CONCLUSIONS Although the intraoral scanning method with Lythos© seems to have drawbacks in terms of reliability, validity and conformity to the indirect alginate methods, all procedures proved to be clinically equivalent for diagnostic purposes.
Collapse
|
5
|
Schnutenhaus S, Gröller S, Luthardt RG, Rudolph H. Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: A prospective controlled clinical study. Clin Implant Dent Relat Res 2018; 20:541-549. [PMID: 29691987 DOI: 10.1111/cid.12614] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Revised: 01/27/2018] [Accepted: 03/17/2018] [Indexed: 11/26/2022]
Abstract
BACKGROUND Template-guided implant placement is a method for optimal implant positioning from a prosthetic and surgical viewpoint. The treatment planning is based on three-dimensional X-ray data and model scan data, as well as on prosthetic planning (set-up). These data are matched (superimposed) with the aid of an X-ray template or by manual matching without special referencing. PURPOSE The objective of this prospective controlled clinical study was to determine and compare the accuracy of the match with and without an additional X-ray template. MATERIALS AND METHODS The DICOM data of the cone beam computed tomography (CBCT) were converted into surface data sets and then superimposed on model scan data using three different methods (manually, based on an X-ray template, or semi-automatically with computer assistance). The mean deviations between these results of these matching methods were investigated. RESULTS The procedures achieved a matching accuracy of 0.2 mm on average. This corresponds to the resolution of the CBCT (0.2 voxels). Further studies are necessary to verify the procedure even for patients with few (0-4) residual teeth. CONCLUSION In the presence of a sufficient number of residual teeth, the manual matching of model scan data with CBCT data is sufficiently accurate for implant planning and template-guided implementation. The results of the present study suggest that X-ray templates can be dispensed with saving the patient a substantial amount of time and money.
Collapse
Affiliation(s)
- Sigmar Schnutenhaus
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| | - Sebastian Gröller
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| | - Ralph G Luthardt
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| | - Heike Rudolph
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| |
Collapse
|
6
|
Comparison of the accuracy of direct and indirect three-dimensional digitizing processes for CAD/CAM systems – An in vitro study. J Prosthodont Res 2017; 61:177-184. [DOI: 10.1016/j.jpor.2016.07.001] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Revised: 06/16/2016] [Accepted: 07/06/2016] [Indexed: 11/17/2022]
|
7
|
Retrospective study to determine the accuracy of template-guided implant placement using a novel nonradiologic evaluation method. Oral Surg Oral Med Oral Pathol Oral Radiol 2016; 121:e72-9. [DOI: 10.1016/j.oooo.2015.12.012] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2015] [Revised: 12/04/2015] [Accepted: 12/15/2015] [Indexed: 02/06/2023]
|
8
|
RUDOLPH H, GRAF MRS, KUHN K, RUPF-KÖHLER S, EIRICH A, EDELMANN C, QUAAS S, LUTHARDT RG. Performance of dental impression materials: Benchmarking of materials and techniques by three-dimensional analysis. Dent Mater J 2015; 34:572-84. [DOI: 10.4012/dmj.2014-197] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Heike RUDOLPH
- Department of Prosthetic Dentistry, Center of Dentistry, Ulm University
| | | | - Katharina KUHN
- Department of Prosthetic Dentistry, Center of Dentistry, Ulm University
| | | | - Alfred EIRICH
- Department of Prosthetic Dentistry, Center of Dentistry, Ulm University
| | - Cornelia EDELMANN
- Department of Prosthetic Dentistry, Center of Dentistry, Ulm University
| | | | - Ralph G. LUTHARDT
- Department of Prosthetic Dentistry, Center of Dentistry, Ulm University
| |
Collapse
|
9
|
|
10
|
Schaefer O, Decker M, Wittstock F, Kuepper H, Guentsch A. Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro. J Dent 2014; 42:677-83. [PMID: 24508541 DOI: 10.1016/j.jdent.2014.01.016] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2013] [Revised: 01/15/2014] [Accepted: 01/27/2014] [Indexed: 10/25/2022] Open
Abstract
OBJECTIVES To investigate the effects, digital impression procedures can have on the three-dimensional fit of ceramic partial crowns in vitro. METHODS An acrylic model of a mandibular first molar was prepared to receive a partial coverage all-ceramic crown (mesio-occlusal-distal inlay preparation with reduction of all cusps and rounded shoulder finish line of buccal wall). Digital impressions were taken using iTero (ITE), cara TRIOS (TRI), CEREC AC with Bluecam (CBC), and Lava COS (COS) systems, before restorations were designed and machined from lithium disilicate blanks. Both the preparation and the restorations were digitised using an optical reference-scanner. Data were entered into quality inspection software, which superimposed the records (best-fit-algorithm), calculated fit-discrepancies for every pixel, and colour-coded the results to aid visualisation. Furthermore, mean quadratic deviations (RMS) were computed and analysed statistically with a one-way ANOVA. Scheffé's procedure was applied for multiple comparisons (n=5, α=0.05). RESULTS Mean marginal (internal) discrepancies were: ITE 90 (92) μm, TRI 128 (106) μm, CBC 146 (84) μm, and COS 109 (93) μm. Differences among impression systems were statistically significant at p<0.001 (p=0.039). Qualitatively, partial crowns were undersized especially around cusp tips or the occluso-approximal isthmus. By contrast, potential high-spots could be detected along the preparation finishline and at central occlusal boxes. CONCLUSIONS Marginal and internal fit of milled lithium disilicate partial crowns depended on the employed digital impression technique. CLINICAL SIGNIFICANCE The investigated digital impression procedures demonstrated significant fit discrepancies. However, all fabricated restorations showed acceptable marginal and internal gap sizes, when considering clinically relevant thresholds reported in the literature.
Collapse
Affiliation(s)
- Oliver Schaefer
- Policlinic of Prosthetic Dentistry and Material Science, Centre for Dental Medicine, Jena University Hospital, Jena, Germany.
| | - Mike Decker
- Policlinic of Prosthetic Dentistry and Material Science, Centre for Dental Medicine, Jena University Hospital, Jena, Germany
| | - Frank Wittstock
- Policlinic of Prosthetic Dentistry and Material Science, Centre for Dental Medicine, Jena University Hospital, Jena, Germany
| | - Harald Kuepper
- Policlinic of Prosthetic Dentistry and Material Science, Centre for Dental Medicine, Jena University Hospital, Jena, Germany
| | - Arndt Guentsch
- Policlinic of Prosthetic Dentistry and Material Science, Centre for Dental Medicine, Jena University Hospital, Jena, Germany; School of Dentistry, Marquette University, Milwaukee, WI, USA
| |
Collapse
|
11
|
Stober T, Bermejo JL, Rammelsberg P, Schmitter M. Enamel wear caused by monolithic zirconia crowns after 6 months of clinical use. J Oral Rehabil 2014; 41:314-22. [DOI: 10.1111/joor.12139] [Citation(s) in RCA: 106] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/23/2013] [Indexed: 11/27/2022]
Affiliation(s)
- T. Stober
- Department of Prosthodontics; University Hospital Heidelberg; Heidelberg Germany
| | - J. L. Bermejo
- Institute of Medical Biometry and Informatics; University Hospital Heidelberg; Heidelberg Germany
| | - P. Rammelsberg
- Department of Prosthodontics; University Hospital Heidelberg; Heidelberg Germany
| | - M. Schmitter
- Department of Prosthodontics; University Hospital Heidelberg; Heidelberg Germany
| |
Collapse
|