1
|
Filauro M, Ioppi A, Vallin A, Sampieri C, De Vecchi M, Gabella G, Benzi P, Mora F, Peretti G. Office-Based Treatment of Vocal Fold Polyps and Reinke's Edema: A Rational Comparison With Suspension Laryngoscopy. Laryngoscope 2023; 133:2665-2672. [PMID: 36647733 DOI: 10.1002/lary.30576] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 12/17/2022] [Accepted: 01/05/2023] [Indexed: 01/18/2023]
Abstract
OBJECTIVE Benign laryngeal lesions have traditionally been treated through suspension laryngoscopy under general anesthesia (GA). Recently, the development of operative videoendoscopes coupled with photoangiolytic lasers has allowed clinicians to treat these conditions in the outpatient clinic. We report our experience in the office-based (OB) setting for the treatment of patients affected by vocal fold polyps (VFPs) and Reinke's edema (RE), comparing it to patients treated under GA. METHODS A retrospective analysis was conducted on patients affected by VFP or RE. A 445 nm diode blue laser was used through the operative channel of a flexible video-endoscope for OB procedures, while GA surgeries were carried out with cold steel instrumentation. The Voice Handicap Index-10 (VHI-10) represented the primary outcome. Endoscopic outcomes, duration, and morbidity of the procedures were investigated as secondary outcomes. RESULTS A total of 153 patients were retrospectively enrolled. 52 were treated in an OB setting, while 91 underwent GA. Regarding patients with RE, both the OB and GA cohorts showed a significant improvement in VHI-10 (from 12.7 to 2.6 and 19.5 to 5.1, respectively; p < 0.001), as did those with VFPs (from 11.8 to 2.3 and 15.9 to 2.9 respectively; p < 0.001). No differences were found when comparing VHI-10 in the OB and GA cohorts. The mean procedural time of OB treatment (4.9 min) was significantly shorter than GA (37.1 min). No adverse events were reported. CONCLUSION Our data demonstrate the efficacy and safety of the OB setting. For selected patients, OB treatments offer comparable vocal outcomes, favorable morbidity, and reduced operation times, making them an appealing alternative to the traditional approach. LEVEL OF EVIDENCE 3 Laryngoscope, 133:2665-2672, 2023.
Collapse
Affiliation(s)
- Marta Filauro
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
- Department of Medical Science (DIMES), University of Genoa, Genoa, Italy
| | - Alessandro Ioppi
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Alberto Vallin
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Claudio Sampieri
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Marta De Vecchi
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Giulia Gabella
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Pietro Benzi
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Francesco Mora
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Giorgio Peretti
- Unit of Otorhinolaryngology - Head and Neck Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| |
Collapse
|
2
|
The Impact of Laser Thermal Effect on Histological Evaluation of Oral Soft Tissue Biopsy: Systematic Review. Dent J (Basel) 2023; 11:dj11020028. [PMID: 36826173 PMCID: PMC9955047 DOI: 10.3390/dj11020028] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/13/2023] [Accepted: 01/13/2023] [Indexed: 01/19/2023] Open
Abstract
The aim of the study is to review the literature to observe studies that evaluate the extent of the thermal effect of different laser wavelengths on the histological evaluation of oral soft tissue biopsies. An electronic search for published studies was performed on the PubMed and Scopus databases between July 2020 and November 2022. After the selection process, all the included studies were subjected to quality assessment and data extraction processes. A total of 28 studies met the eligibility criteria. The most studied laser was the carbon dioxide (CO2) laser, followed by the diode laser 940 nm-980 nm. Six studies were focused on each of the Erbium-doped Yttrium Aluminium Garnet (Er:YAG), Neodymium-doped Yttrium Aluminum Garnet (Nd:YAG) lasers, and diode lasers of 808 nm and 445 nm. Three studies were for the Potassium Titanyl Phosphate (KTP) laser, and four studies were for the Erbium, Chromium-doped Yttrium, Scandium, Gallium, and Garnet (Er,Cr:YSGG) laser. The quality and bias assessment revealed that almost all the animal studies were at a low risk of bias (RoB) in the considered domains of the used assessment tool except the allocation concealment domain in the selection bias and the blinding domain in the performance bias, where these domains were awarded an unclear or high score in almost all the included animal studies. For clinical studies, the range of the total RoB score in the comparative studies was 14 to 23, while in the non-comparative studies, it was 11 to 15. Almost all the studies concluded that the thermal effect of different laser wavelengths did not hinder the histological diagnosis. This literature review showed some observations. The thermal effect occurred with different wavelengths and parameters and what should be done is to minimize it by better adjusting the laser parameters. The extension of margins during the collection of laser oral biopsies and the use of laser only in non-suspicious lesions are recommended because of the difficulty of the histopathologist to assess the extension and grade of dysplasia at the surgical margins. The comparison of the thermal effect between different studies was impossible due to the presence of methodological heterogeneity.
Collapse
|
3
|
Ran T, Lin C, Ma T, Qin Y, Li J, Zhang Y, Xu Y, Li C, Wang M. Ultra-Pulsed CO 2 Laser Osteotomy: A New Method for the Bone Preparation of Total Knee Arthroplasty. Front Bioeng Biotechnol 2022; 10:858862. [PMID: 35573227 PMCID: PMC9096707 DOI: 10.3389/fbioe.2022.858862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 03/31/2022] [Indexed: 12/04/2022] Open
Abstract
Cementless total knee arthroplasty (TKA) can achieve long-term biological fixation, but its application is limited by the risk of early aseptic loosening. One of the important reasons for early aseptic loosening is that mechanical osteotomy tools cannot achieve ideal bone preparation because of poor accuracy and serious bone tissue damage produced by them. Therefore, we designed an ultra-pulsed CO2 laser osteotomy system to solve these problems. To reveal the safety at the tissue and cell levels of the ultra-pulsed CO2 laser osteotomy system, a series of experiments on distal femur osteotomy in animals were performed. Then, the bone surface characteristics were analyzed through scanning electron microscopy, and the bone thermal and mechanical damage was evaluated via histological analysis. Finally, mesenchymal stem cells (MSCs) were inoculated on the bone surfaces prepared by the two osteotomy tools, and the effect of cell adhesion was analyzed through a confocal laser scanning microscope (CLSM). We successfully achieved TKA bone preparation of animal knees with the ultra-pulsed CO2 laser osteotomy system. Moreover, the biological evaluation results indicated that compared with the traditional mechanical saw, the laser can preserve the natural bone structure and cause no thermal damage to the bone. In addition, CLSM examination results showed that the laser-cut bone surface was more conducive to cell adhesion and infiltration than the bone surface cut by a mechanical saw. Overall, these results indicate that ultra-pulsed CO2 laser can achieve non-invasive bone cutting, which can be a new option for TKA bone preparation and has the potential to lead in the future.
Collapse
Affiliation(s)
- Tianfei Ran
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Chuanchuan Lin
- Department of Blood Transfusion, Xinqiao Hospital, Amy Medical University (Third Military Medical University), Chongqing, China
| | - Tianying Ma
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Yinyin Qin
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Jie Li
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Yuan Zhang
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Yuan Xu
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Changqing Li
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| | - Min Wang
- Department of Orthopedics, Xinqiao Hospital, Third Military Medical University, Chongqing, China
| |
Collapse
|
4
|
Thermal effect of a 445 nm diode laser on five dental implant systems: an in vitro study. Sci Rep 2021; 11:20174. [PMID: 34635754 PMCID: PMC8505640 DOI: 10.1038/s41598-021-99709-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Accepted: 09/22/2021] [Indexed: 01/10/2023] Open
Abstract
The purpose of this in vitro study was to assess the thermal effect of the 445 nm diode laser on five dental implant systems. In an ailing implant protocol, five commercial dental implant systems were subjected to 445 nm diode laser energy at different wattages [W], exposure times, and modes (continuous wave [CW] vs. pulsed and contact vs. non-contact) of laser beam delivery. Scanning electron microscopy (SEM) allowed the evaluation of irradiated implant surfaces. A total of 2880 temperature response curves were recorded. The 445 nm wavelength caused temperature increases of more than 10 °C at or above the 0.8 W power level working in CW mode for 5 s and in pulsed mode at 3 W for 20 s with 10% duty cycle. Highest rises in temperature were seen in the Straumann Pure ceramic implant, lowest in the Ankylos system. SEM analysis revealed no surface alteration in all systems in non-contact mode. The applied laser is not inherently safe for the decontamination of ailing implants. From the results of this study it was concluded that different dental implant materials and geometries show different temperature response curves when subjected to 445 nm diode laser energy. Clinicians ought to be aware of this. Therefore, manufacturers of laser devices should provide implant-specific laser parameters for the decontamination process. However, both laser irradiation systems can prevent harmful rises in temperature and surface alteration when used at moderate laser parameters.
Collapse
|
5
|
Impellizzeri A, Horodynski M, Serritella E, Palaia G, De Stefano A, Polimeni A, Galluccio G. Uncovering and Autonomous Eruption of Palatally Impacted Canines-A Case Report. Dent J (Basel) 2021; 9:dj9060066. [PMID: 34207531 PMCID: PMC8229895 DOI: 10.3390/dj9060066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 05/31/2021] [Accepted: 06/07/2021] [Indexed: 11/16/2022] Open
Abstract
The impaction of permanent maxillary canine is a common clinical occurrence, and it is observed in 2% of patients who require orthodontic treatment. This case report describes a new orthodontic-surgical approach through the use of CO2 laser, for the exposure of the palatally impacted canines. A 13-year-old female referred to our observation to make an orthodontic examination because of the maxillary primary canines’ persistence in upper arch. Orthopanoramic X-ray showed impaction of both permanent maxillary canines. The family history revealed that the patient’s mother had the same orthodontic problem. Cone Beam Computer Tomography (CBCT) was requested to plan the surgical-orthodontic treatment. Surgical exposure of the impacted canines was performed using a CO2 laser and subsequent periodontal pack application. No orthodontic devices were applied for impacted teeth traction on dental arch. Canines’ movement was monitored at 1, 8 and 16 weeks post-surgery with photo and intraoral scanner CS3500 (CS3500®, Carestream Health, Atlanta, GA, USA). When canine crowns were completely erupted on palatal side, the alignment in the arch with indirect bonding technique was performed. Complete disimpaction of canine crowns was obtained in only four months. As reported in the literature, this case confirms that impacted canines’ exposure to CO2 laser has advantages if compared with traditional surgery: no bleeding during and after the procedure, decontaminant effect on the surgical area, no suture, and a fast spontaneous eruption. Conclusions: The pre-orthodontic uncovering and autonomous eruption of palatally impacted maxillary canines provides simplified, predictable, and more aesthetic outcomes. Furthermore, a significant positive factor is that there is no need to carry out the orthodontic traction of the impacted element, undoubtedly better compliance by the patient during the next alignment phase with the fix orthodontic appliance.
Collapse
|
6
|
Palaia G, D'Alessandro L, Pergolini D, Carletti R, Di Gioia CRT, Romeo U. In vivo clinical and histological thermal effect of a 445 nm diode laser on oral soft tissues during a biopsy. J Oral Sci 2021; 63:280-282. [PMID: 33980770 DOI: 10.2334/josnusd.20-0665] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Blue diode laser emits a 445 nm wavelength light, which is extremely effective with hemoglobin, and has an optimal hemostatic effect. This work analyzes its thermal effects and clinical efficacy, when used to perform excisional biopsies. Forty-two excisional biopsies were performed with the laser; then, the extent of perincisional thermal effects was evaluated and patients were followed up. Average alteration on epithelial tissue was 507.07 µm, and on connective tissue was 320.39 µm. In all the cases, it was possible to obtain a histological diagnosis. Diode lasers can be safely used to perform biopsies; various intra- and postoperative advantages were confirmed.
Collapse
Affiliation(s)
- Gaspare Palaia
- Department of Oral and Maxillofacial Sciences, Sapienza University of Rome
| | | | - Daniele Pergolini
- Department of Oral and Maxillofacial Sciences, Sapienza University of Rome
| | - Raffaella Carletti
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome
| | - Cira R T Di Gioia
- Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome
| | - Umberto Romeo
- Department of Oral and Maxillofacial Sciences, Sapienza University of Rome
| |
Collapse
|
7
|
Palaia G, Renzi F, Pergolini D, Del Vecchio A, Visca P, Tenore G, Romeo U. Histological Ex Vivo Evaluation of the Suitability of a 976 nm Diode Laser in Oral Soft Tissue Biopsies. Int J Dent 2021; 2021:6658268. [PMID: 34007279 PMCID: PMC8100417 DOI: 10.1155/2021/6658268] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 03/24/2021] [Accepted: 04/19/2021] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Laser-induced thermal effects can preclude a safe histological evaluation of biopsy resection margins. The aim of this study was to evaluate the suitability of a 976 nm diode laser in oral soft tissue biopsies in an ex vivo study. MATERIALS AND METHODS A 976 nm diode laser (Solase®, Lazon Medical Laser, China) has been used in the contact mode, using a 400 μm fiber tip, at different parameters from 4 to 6 W in the continuous wave (CW), with a fluence between 3184 and 4777 J/cm2, and pulsed wave (PW) mode, with a fluence between 318,4 and 477,7 J/cm2, to obtain 30 samples from fresh pig cadaver tongues. All specimens were subdivided into 6 groups (from A to F), and each group consisted of 5 samples. Two sections were obtained from each sample. A histological analysis was performed using an optical microscope at magnifications of 5x and 10x. Statistical analysis was carried out using Kruskal-Wallis and Dunn's tests. RESULTS The results showed that histological readability was optimal in all the samples. The thermal damage was negligible in all groups. The average thermal damage was 208.40 ± 133.81 μm in the epithelial tissue and 330.14 ± 147.45 μm in the connective tissue. The statistical analysis showed no differences between the groups (p > 0.05). CONCLUSION A 976 nm diode laser demonstrated good surgical effectiveness that provoked little peripheral damage in the cut edges and allowed a safe histological diagnosis. Clinical Relevance. In oral pathology, many times, there is fear in using the laser to remove some lesions due to its thermal effect on the tissues close to the lesion. This effect is always present in the use of the laser, but the intent is to minimize this effect to have as little alteration as possible on the surrounding tissues.
Collapse
Affiliation(s)
- Gaspare Palaia
- “Sapienza” University of Rome, Department of Oral and Maxillofacial Sciences, Via Caserta 6, Rome 00161, Italy
| | - Federico Renzi
- “Sapienza” University of Rome, Department of Oral and Maxillofacial Sciences, Via Caserta 6, Rome 00161, Italy
| | - Daniele Pergolini
- “Sapienza” University of Rome, Department of Oral and Maxillofacial Sciences, Via Caserta 6, Rome 00161, Italy
| | - Alessandro Del Vecchio
- “Sapienza” University of Rome, Department of Oral and Maxillofacial Sciences, Via Caserta 6, Rome 00161, Italy
| | - Paolo Visca
- Department of Cytology and Cellular Diagnostics, Regina Elena Institute, Via Elio Chianesi 53, Rome 00144, Italy
| | - Gianluca Tenore
- “Sapienza” University of Rome, Department of Oral and Maxillofacial Sciences, Via Caserta 6, Rome 00161, Italy
| | - Umberto Romeo
- “Sapienza” University of Rome, Department of Oral and Maxillofacial Sciences, Via Caserta 6, Rome 00161, Italy
| |
Collapse
|
8
|
Viani MV, Corcione L, Di Blasio C, Bologna-Molina R, Vescovi P, Meleti M. A Single Case Report of Granular Cell Tumor of the Tongue Successfully Treated through 445 nm Diode Laser. Healthcare (Basel) 2020; 8:healthcare8030267. [PMID: 32823546 PMCID: PMC7551446 DOI: 10.3390/healthcare8030267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/21/2020] [Accepted: 08/11/2020] [Indexed: 02/07/2023] Open
Abstract
Oral granular cell tumor (GCT) is a relatively rare, benign lesion that can easily be misdiagnosed. Particularly, the presence of pseudoepitheliomatous hyperplasia might, in some cases, lead to the hypothesis of squamous cell carcinoma. Surgical excision is the treatment of choice. Recurrence has been reported in up to 15% of cases treated with conventional surgery. Here, we reported a case of GCT of the tongue in a young female patient, which was successfully treated through 445 nm diode laser excision. Laser surgery might reduce bleeding and postoperative pain and may be associated with more rapid healing. Particularly, the vaporization effect on remnant tissues could eliminate GCT cells on the surgical bed, thus hypothetically leading to a lower rate of recurrence. In the present case, complete healing occurred in 1 week, and no recurrence was observed after 6 months. Laser surgery also allows the possibility to obtain second intention healing. Possible laser-induced histopathological artifacts should be carefully considered.
Collapse
Affiliation(s)
- Maria Vittoria Viani
- Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy; (L.C.); (P.V.); (M.M.)
- Correspondence:
| | - Luigi Corcione
- Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy; (L.C.); (P.V.); (M.M.)
| | | | | | - Paolo Vescovi
- Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy; (L.C.); (P.V.); (M.M.)
| | - Marco Meleti
- Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy; (L.C.); (P.V.); (M.M.)
| |
Collapse
|
9
|
Impellizzeri A, Horodynski M, Fusco R, Palaia G, Polimeni A, Romeo U, Barbato E, Galluccio G. Photobiomodulation Therapy on Orthodontic Movement: Analysis of Preliminary Studies with a New Protocol. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17103547. [PMID: 32438716 PMCID: PMC7277382 DOI: 10.3390/ijerph17103547] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/09/2020] [Accepted: 05/11/2020] [Indexed: 12/24/2022]
Abstract
This study aimed to investigate the effectiveness of photobiomodulation therapy (PBMT) on the acceleration of orthodontic movements, deriving from its biostimulating and regenerative capacity on soft tissues, consequent to the increase in differentiation, proliferation, and activity of cells that are involved with alveolar bone remodeling. The present randomized controlled trial was conducted on six patients who required extractive orthodontic therapy because their ectopic canines had erupted. A total of eight canines were analyzed, four of which received laser irradiation (i.e., experimental group). Two weeks after the extractions, all canines of the experimental and placebo groups were distalized simultaneously and symmetrically with the laceback retraction technique. The PBMT protocol consisted of four cycles of laser applications, one each on days 0, 3, 7, and 14 of the study, with session treatment durations of 2–4 min. The results of the descriptive analysis on the distal displacement speed of the canines after 1 month of follow-up indicate an average displacement of 1.35 mm for the non-irradiated group and 1.98 mm for the irradiated group. Through inferential analysis, a statistically significant difference (p < 0.05) was found between the average speed of the irradiated canines and the control canines. The low energy density laser used in this study, with the parameters set, was found to be a tool capable of statistically significantly accelerating the distal displacement of canines.
Collapse
|
10
|
Histological Effects of an Innovative 445 Nm Blue Laser During Oral Soft Tissue Biopsy. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17082651. [PMID: 32294912 PMCID: PMC7215754 DOI: 10.3390/ijerph17082651] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 04/08/2020] [Accepted: 04/09/2020] [Indexed: 12/26/2022]
Abstract
Continuously evolving laser devices can be used in various fields; they are an alternative to the traditional cold blade surgery to perform biopsies of oral soft tissues. The aspect focused on in this paper is the possibility to use the 445 nm diode laser (Eltech K-Laser srl, Treviso, Italy) in complete safety, by evaluating its thermal effects during microscopy. A histological evaluation of the alteration of the peri-incisional edges on 10 samples was realized. All excisional biopsies were related to clinically unsuspected lesions and performed by the same expert operator. The surgical procedure was performed with the same laser parameters and the same pathologist evaluated the thermal effect on the samples. An average value of the detected tissue alteration was calculated; the average damage of the epithelium was 650.93 μm, while in the connective tissue it was 468.07 μm. In all the cases a clear diagnosis was possible, and no clinical complications were observed; so, the 445 nm diode laser proved to be a device that can be safely used for biopsies of clinically unsuspicious lesions. Due to the small number of cases, this in vivo preliminary experience needs to be extended.
Collapse
|