1
|
da Silva AMP, Horta Dos Santos FA, Mota RF, Teixeira MKS, Telles DM, Lourenço EJV. Clinical and radiographic outcomes of a two-piece ceramic implant: one year results from a prospective clinical trial. Clin Oral Investig 2024; 28:380. [PMID: 38886209 DOI: 10.1007/s00784-024-05783-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 06/11/2024] [Indexed: 06/20/2024]
Abstract
OBJECTIVE To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.
Collapse
Affiliation(s)
- Alexandre Marques Paes da Silva
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | | | - Rodrigo Franco Mota
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | - Mayla Kezy Silva Teixeira
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil.
| | - Daniel Moraes Telles
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | - Eduardo José Veras Lourenço
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| |
Collapse
|
2
|
Thu MK, Kang YS, Kwak JM, Jo YH, Han JS, Yeo ISL. Comparison between bone-implant interfaces of microtopographically modified zirconia and titanium implants. Sci Rep 2023; 13:11142. [PMID: 37429939 DOI: 10.1038/s41598-023-38432-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 07/07/2023] [Indexed: 07/12/2023] Open
Abstract
The aim of this study was to investigate the surface characteristics and evaluate the bone-implant interfaces of injection molded zirconia implants with or without surface treatment and compare them with those of conventional titanium implants. Four different zirconia and titanium implant groups (n = 14 for each group) were prepared: injection-molded zirconia implants without surface treatment (IM ZrO2); injection-molded zirconia implants with surface treatment via sandblasting (IM ZrO2-S); turned titanium implants (Ti-turned); and titanium implants with surface treatments via sandblasting with large-grit particles and acid-etching (Ti-SLA). Scanning electron microscopy, confocal laser scanning microscopy, and energy dispersive spectroscopy were used to assess the surface characteristics of the implant specimens. Eight rabbits were used, and four implants from each group were placed into the tibiae of each rabbit. Bone-to-implant contact (BIC) and bone area (BA) were measured to evaluate the bone response after 10-day and 28-day healing periods. One-way analysis of variance with Tukey's pairwise comparison was used to find any significant differences. The significance level was set at α = 0.05. Surface physical analysis showed that Ti-SLA had the highest surface roughness, followed by IM ZrO2-S, IM ZrO2, and Ti-turned. There were no statistically significant differences (p > 0.05) in BIC and BA among the different groups according to the histomorphometric analysis. This study suggests that injection-molded zirconia implants are reliable and predictable alternatives to titanium implants for future clinical applications.
Collapse
Affiliation(s)
- Myint Kyaw Thu
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Young Suk Kang
- 618th Medical Company (Dental Area Support)/Dental Health Activity-Korea, Camp Humphreys, APO, AP, 96297, USA
| | - Jeong Min Kwak
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Ye-Hyeon Jo
- Dental Research Institute, Seoul National University, Seoul, 03080, Korea
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea.
| |
Collapse
|
3
|
Wang LN, Meng YF, Feng Y, Wang HC, Mao LB, Yu SH, Wang ZL. Amorphous Precursor-Mediated Calcium Phosphate Coatings with Tunable Microstructures for Customized Bone Implants. Adv Healthc Mater 2022; 11:e2201248. [PMID: 35842766 DOI: 10.1002/adhm.202201248] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Indexed: 01/27/2023]
Abstract
Calcium phosphate (CaP) is frequently used as coating for bone implants to promote osseointegration. However, commercial CaP coatings via plasma spraying display similar microstructures, and thus fail to provide specific implants according to different surgical conditions or skeletal bone sites. Herein, inspired by the formation of natural biominerals with various morphologies mediated by amorphous precursors, CaP coatings with tunable microstructures mediated by an amorphous metastable phase are fabricated. The microstructures of the coatings are precisely controlled by both polyaspartic acid and Mg2+ . The cell biological behaviors, including alkaline phosphatase activity, mineralization, and osteogenesis-related genes expression, on the CaP coatings with different microstructures, exhibit significant differences. Furthermore, in vivo experiments demonstrate the osseointegration in different types of rats and bones indeed favors different CaP coatings. This biomimetic strategy can be used to fabricate customized bone implants that can meet the specific requirements of various surgery conditions.
Collapse
Affiliation(s)
- Li-Na Wang
- Department of Oral and Maxillofacial Surgery, Department of Oral Implantology, School and Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China.,Division of Nanomaterials and Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, Institute of Energy, Hefei Comprehensive National Science Center, CAS Center for Excellence in Nanoscience, Department of Chemistry, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, University of Science and Technology of China, Hefei, 230026, China
| | - Yu-Feng Meng
- Division of Nanomaterials and Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, Institute of Energy, Hefei Comprehensive National Science Center, CAS Center for Excellence in Nanoscience, Department of Chemistry, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, University of Science and Technology of China, Hefei, 230026, China
| | - Yanhuizhi Feng
- Department of Oral and Maxillofacial Surgery, Department of Oral Implantology, School and Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China
| | - Hai-Cheng Wang
- Department of Oral and Maxillofacial Surgery, Department of Oral Implantology, School and Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China
| | - Li-Bo Mao
- Division of Nanomaterials and Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, Institute of Energy, Hefei Comprehensive National Science Center, CAS Center for Excellence in Nanoscience, Department of Chemistry, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, University of Science and Technology of China, Hefei, 230026, China
| | - Shu-Hong Yu
- Division of Nanomaterials and Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, Institute of Energy, Hefei Comprehensive National Science Center, CAS Center for Excellence in Nanoscience, Department of Chemistry, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, University of Science and Technology of China, Hefei, 230026, China
| | - Zuo-Lin Wang
- Department of Oral and Maxillofacial Surgery, Department of Oral Implantology, School and Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China
| |
Collapse
|
4
|
Zirconia versus Titanium Implants: 8-Year Follow-Up in a Patient Cohort Contrasted with Histological Evidence from a Preclinical Animal Model. MATERIALS 2022; 15:ma15155322. [PMID: 35955254 PMCID: PMC9369473 DOI: 10.3390/ma15155322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 07/18/2022] [Accepted: 07/29/2022] [Indexed: 02/04/2023]
Abstract
Zirconia ceramic (ZC) implants are becoming more common, but comparisons between preclinical histology and long-term clinical trials are rare. This investigation comprised (1) 8-year clinical follow-up of one-piece ZC or titanium (Ti) implants supporting full overdentures and (2) histomorphometric analysis of the same implants in an animal model, comparing implants with various surface treatments. Methods: (1) Clinical trial: 24 completely edentulous participants (2 groups of N = 12) received 7 implants (one-piece ball-abutment ZC or Ti; maxilla N = 4, mandible N = 3) restored with implant overdentures. Outcomes after 8-years included survival, peri-implant bone levels, soft-tissue responses, and prosthodontic issues. (2) Preclinical trial: 10 New Zealand sheep received 4 implants bilaterally in the femoral condyle: Southern Implants ZC or Ti one-piece implants, identical to the clinical trial, and controls: Southern ITC® two-piece implants with the same surface or Nobel (NBC) anodised (TiUnite™) surface. %Bone-implant contact (%BIC) was measured after 12 weeks of unloaded healing. Results: 8 of 24 participants (33%) of an average age of 75 ± 8 years were recalled; 21% of original participants had died, and 46% could not be contacted. 80.4% of implants survived; excluding palatal sites, 87.5% of Ti and 79% of ZC implants survived. All failed implants were in the maxilla. Three ZC implants had fractured. Bone loss was similar for Ti vs. ZC; pocket depths (p = 0.04) and attachment levels (p = 0.02) were greater for Ti than ZC implants. (1.7 ± 1.6 mm vs. 1.6 ± 1.3 mm). All implants in sheep femurs survived. %BIC was not statistically different for one-piece blasted surface Ti (80 ± 19%) versus ZC (76 ± 20%) or ITC® (75 ± 16 mm); NBC had significantly higher %BIC than ITC (84 ± 17%, p = 0.4). Conclusion: Short-term preclinical results for ZC and Ti one-piece implants showed excellent bone-implant contact in unloaded femoral sites. This differed from the long-term clinical results in older-aged, edentulous participants. While ZC and Ti implants showed equivalent performance, the risks of peri-implantitis and implant loss in older, completely edentulous patients remain a significant factor.
Collapse
|
5
|
Surface Structure of Zirconia Implants: An Integrative Review Comparing Clinical Results with Preclinical and In Vitro Data. MATERIALS 2022; 15:ma15103664. [PMID: 35629692 PMCID: PMC9143528 DOI: 10.3390/ma15103664] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/13/2022] [Accepted: 05/19/2022] [Indexed: 01/27/2023]
Abstract
Background: The purpose of this review was to analyze and correlate the findings for zirconia implants in clinical, preclinical and in vitro cell studies in relation to surface structure. Methods: Electronic searches were conducted to identify clinical, preclinical and in vitro cell studies on zirconia implant surfaces. The primary outcomes were mean bone loss (MBL) for clinical studies, bone-to-implant contact (BIC) and removal torque (RT) for preclinical studies and cell spreading, cell proliferation and gene expression for cell studies. The secondary outcomes included comparisons of data found for those surfaces that were investigated in all three study types. Results: From 986 screened titles, 40 studies were included for data extraction. In clinical studies, only micro-structured surfaces were investigated. The lowest MBL was reported for sandblasted and subsequently etched surfaces, followed by a sinter and slurry treatment and sandblasted surfaces. For BIC, no clear preference of one surface structure was observable, while RT was slightly higher for micro-structured than smooth surfaces. All cell studies showed that cell spreading and cytoskeletal formation were enhanced on smooth compared with micro-structured surfaces. Conclusions: No correlation was observed for the effect of surface structure of zirconia implants within the results of clinical, preclinical and in vitro cell studies, underlining the need for standardized procedures for human, animal and in vitro studies.
Collapse
|
6
|
Musskopf ML, Finger Stadler A, Wikesjö UME, Susin C. The minipig intraoral dental implant model: A systematic review and meta-analysis. PLoS One 2022; 17:e0264475. [PMID: 35226690 PMCID: PMC8884544 DOI: 10.1371/journal.pone.0264475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 02/10/2022] [Indexed: 12/09/2022] Open
Abstract
OBJECTIVES The objective of this report was to provide a review of the minipig intraoral dental implant model including a meta-analysis to estimate osseointegration and crestal bone remodeling. METHODS A systematic review including PubMed and EMBASE databases through June 2021 was conducted. Two independent examiners screened titles/abstracts and selected full-text articles. Studies evaluating titanium dental implant osseointegration in native alveolar bone were included. A quality assessment of reporting was performed. Random-effects meta-analyses and meta-regressions were produced for bone-implant contact (BIC), first BIC, and crestal bone level. RESULTS 125 out of 249 full-text articles were reviewed, 55 original studies were included. Quality of reporting was generally low, omissions included animal characteristics, examiner masking/calibration, and sample size calculation. The typical minipig model protocol included surgical extraction of the mandibular premolars and first molar, 12±4 wks post-extraction healing, placement of three narrow regular length dental implants per jaw quadrant, submerged implant healing and 8 wks of osseointegration. Approximately 90% of studies reported undecalcified incandescent light microscopy histometrics. Overall, mean BIC was 59.88% (95%CI: 57.43-62.33). BIC increased significantly over time (p<0.001): 40.93 (95%CI: 34.95-46.90) at 2 wks, 58.37% (95%CI: 54.38-62.36) at 4 wks, and 66.33% (95%CI: 63.45-69.21) beyond 4 wks. Variability among studies was mainly explained by differences in observation interval post-extraction and post-implant placement, and implant surface. Heterogeneity was high for all studies (I2 > 90%, p<0.001). CONCLUSIONS The minipig intraoral dental implant model appears to effectively demonstrate osseointegration and alveolar bone remodeling similar to that observed in humans and canine models.
Collapse
Affiliation(s)
- Marta Liliana Musskopf
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Amanda Finger Stadler
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Ulf ME Wikesjö
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Cristiano Susin
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| |
Collapse
|
7
|
Jaeggi M, Gyr S, Astasov-Frauenhoffer M, Zitzmann NU, Fischer J, Rohr N. Influence of different zirconia surface treatments on biofilm formation in vitro and in situ. Clin Oral Implants Res 2022; 33:424-432. [PMID: 35137461 PMCID: PMC9304171 DOI: 10.1111/clr.13902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/10/2022] [Accepted: 01/30/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To determine if the surface treatment of zirconia affects biofilm formation in an in vitro three-species biofilm model and in situ. MATERIAL AND METHODS Zirconia surfaces considered for the transmucosal portion of a zirconia implant were compared with polished pure titanium grade 4 (Tp). Discs 13 mm in diameter of either polished (Zp), polished and heat-treated (Zpt), machined (Zm), machined and heat-treated (Zmt) and sandblasted, etched and heat-treated (Z14) zirconia were fabricated. Surface roughness and wettability of specimens was measured. Biofilm formation was evaluated by safranin staining and scanning electron microscopy (SEM) using a three-species model, and intraorally with 16 volunteers carrying oral splints in two independent experiments. Relative biofilm formation was compared with Kruskal-Wallis followed by Bonferroni post-hoc test (α=0.05). RESULTS In vitro biofilm formation with optical density values on Zp (0.14±0.01), Zpt (0.14±0.02), Zm (0.13±0.01) and Zmt (0.13±0.01) was significantly lower than on Tp (0.21±0.05) and Z14 (0.20±0.04) (p<0.05). In situ biofilm formation was significantly higher on Z14 (0.56±0.45) (p<0.05), while no significant differences in optical density were observed among Zp (0.25±0.20), Zm (0.36±0.34) and Tp (0.28±0.22). SEM analysis supported quantitative findings. CONCLUSIONS In the in vitro three-species biofilm model differences in material and surface roughness affected biofilm formation. In situ biofilm formation was mainly affected by the surface roughness of the specimens. Polishing of zirconia is recommended to reduce biofilm formation while heat-treatment has no significant effect.
Collapse
Affiliation(s)
- Marco Jaeggi
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Sharon Gyr
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Monika Astasov-Frauenhoffer
- Department of Research, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Nicola U Zitzmann
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Jens Fischer
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Nadja Rohr
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland.,Department of Research, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| |
Collapse
|
8
|
Thomé G, Uhlendorf J, Vianna CP, Caldas W, Bernardes SR, Trojan LC. Clinical and radiographic success of injection-molded 2-piece zirconia implants submitted to immediate loading: A 12-month report of two cases. Clin Case Rep 2021; 9:e05118. [PMID: 34917363 PMCID: PMC8643492 DOI: 10.1002/ccr3.5118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 10/26/2021] [Accepted: 11/07/2021] [Indexed: 11/07/2022] Open
Abstract
This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection-molded 2-piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri-implantitis signs, complete implant osseointegration, good marginal bone-level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.
Collapse
Affiliation(s)
- Geninho Thomé
- Department of ImplantologyLatin American Institute for Research and Dental Education (ILAPEO); Scientific President of NeodentCuritibaBrazil
| | | | | | | | - Sergio Rocha Bernardes
- Department of ImplantologyLatin American Institute for Research and Dental Education (ILAPEO); Head of Global Research & Education of NeodentCuritibaBrazil
| | | |
Collapse
|